Military Engineer Services Tender
Search for the latest Gujarat tenders online related to civil works, road & transport, pipelines and more easily here on BidAssist. Here you can get any and every tender that is posted on the eProcurement Gujarat website, minus the clutter. No need for a tender ID, as on BidAssist, you can view any Gujarat tender by merely typing Gujarat in the search box.
Costs
EMD
₹ 5,02,800Document Cost
₹ 2,000Tender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2024_MES_681416_1Bid Award Id
ViewTender No
8915/E8Tender Authority
Military Engineer Services ViewPurchaser Address
-Website
http://http://mes.gov.in/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
BOQ Items
... More
SCH 'A' PART-IV : "ROAD / PATH / CULVERT AND HARD STANDING" Total of Schedule 'A' Part-IV brought forwarded from Serial Page No. 29
1
-
-
... More
SCH 'A' PART-V: "EXTERNAL ELECTRIC SUPPLY" Total of Schedule 'A' Part-V brought forwarded from Serial Page No. 34
1
-
-
... More
SCH 'A' PART-VI"MISC WORKS"
-
-
-
... More
ROAD / PATH / CULVERT AND HARD STANDING
-
-
-
... More
Removing Sand material by mechanical means depositing where directed complete all as specified and directed by Engineer-in-Charge
600
-
-
... More
Cutting in cement concrete of 200 mm deep and 10 mm wide by early entry saw cut using diamond bi-cutter of appropriate size, straight and smooth edges. Joint cleaned thoroughly with application of compressed air. Joint shall be made dry, vacuum cleaned and free of dirt, oil, vegetation and othe debris complete all as specified and directed by Engineer-in-Charge
350
-
-
... More
EXTERNAL ELECTRIC SUPPLY
-
-
-
... More
Supply, installing , testing and commisioning step down Transformer, indoor type , HT 11 KV, 3 phase, LT 433 volts, 50 Hz ,3 phase 4 wire oil cooled (ONAN) including of first fiil of transformer oil of dielectric strength not less than 50 KV,electrolyte grade ,copper wound in accordance with vector group DYN 11 with neutral brought out on LV side with tapping on HV side to vary secondary voltage upto + or - 7.5 % instep of 2.5% with externally operated off load type tap changing switch ,locking arrengement , Energy efficient 3 star rated complete with all standard fittings all as specified and directed by Engineer-in-Charge of capacity 1000 KVA with following technical features:- a) Rating- HV-11KV , LV 433 volts
b) Winding connections- HV-Delta, LV-Star
c) Tappings on HV :- +- 2.5%, total; 7.5% ,OFF Circuit links. d) Insulation class - 'H'
e) Applicable Standards -IS:1180 /IEC-60726
f) Enclosure/housing- made of not less than 2mm thick CRCA sheet , IP-23 ,for indoor location ,powder coated, duly ventilated.
g) Termination- (i) HV & LV cable box for easy connection.
(ii) HV&LV cable glands of standard rating.
h) Duty - Distribution transformer.
j) Noise level:-Less than 69 Db at 1 mtr. k) Full load losses :- As per latest IS.
l) No load losses:- As per latest IS.
n) Protection Device (i) Protection relay against temperature rise for tripping and ,alarm be also provided to sound during high temperature of winding.
(ii) Surge protection (iii) Protection against over current and earth fault.
Note :-
i) The Contractor shall submit the technical drawing, Constructional drawings, safety features drawing, Factory certificate etc for approval of accepting officer.
(ii) the cost of platform for installation of transformer according to OEM reccomondation deemed to be included in rate quoted.
(iii) The contractor shall intimate for factory inspection for routine tests as per IS & ANSIC-57.12.90 (Latest revision) in the OEM factory in presence of rep of nominated by accepting officer before despatch from factory.
2
-
-
... More
Supply, installation, commissioning and testing of Main LT Panel of suitable size, factory made, CPRI type tested, outdoor, cubical compartmental type, double door, both side openable with hinged doors & locking arrangement, made out of 2 mm thick mild steel CRCA sheet, supported and fixed on structural frame of angle iron of size 50 mm x 50 mm x 6 mm, including earthing stud, labeling, painting to all internal & external exposed steel surfaces with powder coating paint (7 tank process), duly fixed in ground with PCC foundation (1:2:4) type B1, with danger notice plate of 1.6 mm thick mild steel sheet, vitreous enameled (white) with letters figures and conventional skull and bones in signal red colour, suitable for 3- Phase 4 Wire system, 500 V grade with necessary wiring, PVC sheathed stranded copper conductor of appropriate length size, including fixing glands, lugs bolts, screws etc. all complete as specified and directed. (installed for 1000 KVA TR main panel )
BUSBAR CHAMBER : 2400 Amps uniformly rated, continuous duty, 415 V AC, 3 Phase and full size Neutral electrolytic grade 99.95% purity Tinned Copper (Throughout the length) busbars with colour coded heat shrink sleeves supported on SMC type grip supports, 50 KA for 1 sec.
INCOMING
a) 1600 A, 4 pole ACB with TM based release for complete LSIG protections and suitable for 415V, 50 Hz, A.C Supply and having Ics = Icu= 50 KA. The ACB shall be complete as per technical specifications- 02 Nos. b) phase indicating light through protected by 2 amps MCB’s. - 2 set
c) Electronic Digital Load Manager with ready RS485 communication port and MODBUS protocol. - 2 set and 6 nos. 1200/5 amps, Bar Primary, 5 VA Burden, CL 1 accuracy CTs . - 2 set, d) 0-500 Volt digital voltmeter with selector switch shall be protected by 2 amp TP MCB’s - 2 set, e) Breaker ON / OFF / TRIP indicating lights with control MCB’s - 2 set.
Bus Coupler - 1600 A ACB 4 Pole 415 V 50 Hz 50 KA -01 No
OUTGOING a) 800 amps 4 pole ACB with TM based release for complete LSIG protections and suitable for 415V, 50 Hz, A.C Supply and having Ics = Icu= 36 KA. The ACB shall be complete as per technical specifications - 04 Nos. b) 400 amps 4 pole MCCB with TM based release for complete LSIG protections and suitable for 415V, 50 Hz, A.C Supply and having Ics = Icu= 36 KA. The MCCB shall be complete as per technical specifications- 02 Nos
1
-
-
... More
Supply, installation, commissioning and testing of Feedar Pillar Panel of suitable size, factory made, CPRI type tested, outdoor, cubical compartmental type, double door, both side openable with hinged doors & locking arrangement, made out of 2 mm thick mild steel CRCA sheet, supported and fixed on structural frame of angle iron of size 50 mm x 50 mm x 6 mm, including earthing stud, labeling, painting to all internal & external exposed steel surfaces with powder coating paint (7 tank process), duly fixed in ground with PCC foundation (1:2:4) type B1, with danger notice plate of 1.6 mm thick mild steel sheet, vitreous enameled (white) with letters figures and conventional skull and bones in signal red colour, suitable for 3- Phase 4 Wire system, 500 V grade with necessary wiring, PVC sheathed stranded copper conductor of appropriate length size, including fixing glands, lugs bolts, screws etc. all complete as specified and directed
BUSBAR CHAMBER 1300 Amps uniformly rated, continuous duty, 415 V AC, 3 Phase and full size Neutral electrolytic grade 99.95% purity Tinned Copper (Throughout the length) busbars with colour coded heat shrink sleeves supported on SMC type grip supports, 25 KA for 1 sec.
INCOMING
(a) 800 A, 4 pole ACB with TM based release for complete LSIG protections and suitable for 415V, 50 Hz, A.C Supply and having Ics = Icu= 50 KA. The ACB shall be complete as per technical specifications and single line diagram - 01No . b) phase indicating light through protected by 2 amps MCB’s. - 1 set
c) Electronic Digital Load Manager with ready RS485 communication port and MODBUS protocol. - 1 set and 3 nos. 1200/5 amps, Bar Primary, 5 VA Burden, CL 1 accuracy CTs . - 1 set, d) 0-500 Volt digital voltmeter with selector switch shall be protected by 2 amp TP MCB’s - 1 set, e) Breaker ON / OFF / TRIP indicating lights with control MCB’s - 1 set.
4
-
-
... More
OUTGOING a) 800 amps 4 pole ACB with TM based release for complete LSIG protections and suitable for 415V, 50 Hz, A.C Supply and having Ics = Icu= 50 KA. The ACB shall be complete as per technical specifications - 01 Nos. b) 400 amps 4 pole MCCB with TM based release for complete LSIG protections and suitable for 415V, 50 Hz, A.C Supply and having Ics = Icu= 36 KA. The MCCB shall be complete as per technical specifications- 01 Nos
c) 250 amps 4 pole MCCB with TM based release for complete LSIG protections and suitable for 415V, 50 Hz, A.C Supply and having Ics = Icu= 36 KA. The MCCB shall be complete as per technical specifications- 01 Nos
d) 100 amps 4 pole MCCB with TM based release for complete LSIG protections and suitable for 415V, 50 Hz, A.C Supply and having Ics = Icu= 36 KA. The MCCB shall be complete as per technical specifications- 01 Nos
Note for Ser item No 8.03 and 8.04
(i) The Contractor shall submit the technical drawing, Constructional drawings, safety features drawing, Factory certificate etc for approval of accepting officer.
(ii) the cost of platform for installation according to OEM reccomondation deemed to be included in rate quoted.
(iii) The contractor shall intimate for factory inspection for routine tests as per IS & ANSIC-57.12.90 (Latest revision) in the OEM factory in presence of rep of nominated by accepting officer before despatch from factory
-
-
-
... More
Supply and fix Servo Voltage stabilizer for automatic operation, three phase, naturally oil cooled, indoor type, copper wound class of insulation 'H' , micro processsing control , with digital metering & designed for input variation between 300 V to 480 V with output voltage stabilized at 415 with accuracy ± 2.5% and speed of correction 8 Volts per second and of capacity 1000 KVA , ,the details technical drawing and specification to be submitted for approval of Accepting officer.
2
-
-
... More
Supply and laying of Double Walled Corrugated (DWC) HDPE pipe of following size of conforming to IS 16205 Part -24 including necessary bends,coupling ,tees, reducers, spacers,end caps, rubber rings etc having pressure rating not less than 450 N through trenches/wall/floor/on pole in any type of soil for protection of electric cable complete all as directed by Engr-In Charge
-
-
-
... More
(a) 110/94 mm outer/inner dia
570
-
-
... More
(b) 120/102 mm outer/inner dia
3002
-
-
... More
M&L for Rectangular RCC Route Marker, 750x200x75 MM including letters writing ( HT Cable 11000 V) including fixing with PCC complete all as specified and directed by Engineer-in-Charge.
100
-
-
... More
M & L Boring of holes under road, pavement, hard standing by trenchless technology using ultra sounding technique and necessary machine including HDPE pipe of 150 mm dia suitable for 0.4 mpa working pressure.
Note- Contractor shall be drill hole without damages to existance utility, if occur, it will be repaired by contractor (No extra amount should be paid to Contractor for repairing).
18
-
-
... More
Material and labour for GI perforated cable tray made out of not less than 2 mm thick GI sheet including anchor fasteners, supporting whole threaded rod, bolts, nuts, washers etc. complete all as specified and directed.