Madhya Gujarat Vij Company Limited Tender
Search for the latest Gujarat tenders online related to civil works, road & transport, pipelines and more easily here on BidAssist. Here you can get any and every tender that is posted on the eProcurement Gujarat website, minus the clutter. No need for a tender ID, as on BidAssist, you can view any Gujarat tender by merely typing Gujarat in the search box.
Costs
EMD
₹ 30,000Document Cost
Refer DocumentsTender Fee
₹ 1,475
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
150710Tender No
JAM-58/01-2025Tender Authority
Madhya Gujarat Vij Company Limited ViewPurchaser Address
-Website
http://http://www.mgvcl.in/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
01.Padra 2 On line Tender Notice.pdf
02 OH scedule B Padra 2 sdn.pdf
03.Commercial Terms and Conditions .pdf
DECLARATION IN REGARD TO RELATIONSHIP WITH EMPLOYEE.pdf
BOQ Items
... More
Erection of a single pole structure with mounting of a B switch, DO fuse, transformers, lightning arresters, distribution box. 8 to 9 & 11-meter steel poles including excavation of pits and refilling of earth, carting of transformers from store to site, fixing of channels, supporting angles, bracing, cross arms, clamps, anti-climbing devices, danger boards, conductor and cable wiring, etc. Complete painting of poles and fabricated materials used on the poles and numbering as per standard specification, but excluding erection of guy sets and earthing.
7
5305
-
... More
Erection of a single pole structure with mounting of a B switch, DO fuse, transformers, lightning arresters, and without a distribution box. 8 to 9 and 11-meter steel poles including excavation of pits and refilling of earth, carting of transformers from store to site, fixing of channels, supporting angles, bracing, crossarms, clamps, anti-climbing devices, danger boards, conductor and cable wiring, etc. Complete painting of poles and fabricated materials used on the poles and numbering as per standard specification, but excluding erection of guy sets and earthing.
7
4081
-
... More
Erection of a double pole structure with mounting of a B switch, DO fuse, transformers, lightning arresters, and distribution box. 8 to 9 & 11-meter steel poles including excavation of pits and refilling of earth, carting of transformers from store to site, fixing of channels, supporting angles, bracing, cross arms, clamps, anti-climbing devices, danger boards, conductor and cable wiring, etc. Complete painting of poles and fabricated materials used on the poles and numbering as per standard specification, but excluding erection of guy sets and earthing.
7
10609
-
... More
Erection of a double pole structure with mounting of a B switch, DO fuse, transformers, lightning arresters, and without a distribution box. 8 to 9 and 11-meter steel poles, including excavation of pits and refilling of earth, carting of transformers from store to site, fixing of channels, supporting angles, bracing, crossarms, clamps, anti-climbing devices, danger boards, conductor and cable wiring, etc. Complete painting of poles and fabricated materials used on the poles and numbering as per standard specification, but excluding erection of guy sets and earthing.
7
9385
-
... More
Erection of guy sets including excavation of pits and refilling of earth, as per standard specification with stay clamps, stay wires, anchor rod, turn buckle, eye bolt, guy insulator, cement concrete block, etc., but excluding concreting.
100
561
-
... More
Concreting/muffing of poles, guy wires etc., including cost of cement and metal (1:2:4) and water etc., as per CCM-20 grade standard specification.
5
8015
-
... More
Erection of coil type earthing including cost of coal and salt, etc., but without cost of GI wire and coil. As per standard specification: 10 kg salt + 10 kg coal. GI wire to be passed through PVC rigid pipe for suitable length as provided by the site/design engineer in charge.
10
605
-
... More
Stringing of 34 mm², 55 mm², and AAA conductor for 11 kV & LT lines, including fixing of insulators, binding, jumpering, etc.
10
2111
-
... More
Stringing of 100 mm2 ACSR/DOG conductor for 11 kV & LT lines, including fixing of insulators, binding, jumpering, etc.
10
4861
-
... More
The work of stringing ABC conductors of the following sizes, including fitting of all accessories i.e., special design suspension/tension clamp, fixing of cross arm, LT shackle insulator, etc., for fixing messenger wire complete, as required and directed by the Engineer-in-Charge: A: 3 x 50 mm² + 1 x 16 mm² + 1 x 35 mm²; B: 3 x 50 mm² + 1 x 16 mm² + 1 x 25 mm².
5
24057
-
... More
The work of stringing ABC of the following sizes, including fitting of all accessories i.e., special design suspension/tension clamp, fixing of cross arm, LT shackle insulator, etc., for fixing of messenger wire complete, as required and directed by the engineer-in-charge: A: 1 x 35mm2 + 1 x 25mm2.
5
9625
-
... More
The work of stringing 11 kV ABC of the following sizes in an urban area, including fitting of all accessories i.e., special design suspension/tension clamp, fixing of cross arm, binding to pin insulator, preparing shackle point jumpers etc., as required and directed by the engineer-in-charge:
A: 3 x 95 mm² + 1 x 80 mm²
B: 3 x 70 mm² + 1 x 70 mm²
3
45107
-
... More
The work of stringing 11 KV ABC of the following sizes in a rural area, including fitting of all accessories i.e., special design suspension/tension clamp, fixing of cross arms, binding to pin insulators, preparing shackle point jumpers etc., as required and directed by the engineer-in-charge:
A: 3 x 95mm² + 1 x 80mm²
B: 3 x 70mm² + 1 x 70mm²
3
48117
-
... More
Providing guarding to HT line on road/rail crossing.
46
70
-
... More
Providing guarding of LT line on road/rail crossing
60
70
-
... More
LT LINE TAPPING SINGLE PHASE.
25
51
-
... More
LT LINE TAPPING THREE PHASE.
25
93
-
... More
Laying of overhead LT cable for road crossing, HT line crossing and telephone line crossing etc. (per span).
20
263
-
... More
Dismantling of all sizes (8, 9, 11, 13... meters) of RSJ (girder) poles, including dismantling of relevant channels, cross arms, insulators, jumpers, binding, and earthing, etc. INCLUDING Cr. IN STORE.
25
974
-
... More
Dismantling of PSC poles including dismantling of relevant channels, cross arms, insulators, jumpers, binding, earthing, etc. INCLUDING Cr. IN STORE.
50
581
-
... More
Dismantling of conductor from line, including Cr. in store.
20
1055
-
... More
Dismantling of 8-meter PSC DP structure, including credit in store.
20
1322
-
... More
Dismantling of 8-meter PSC pole transformer structure up to 100 kVA, including crane in store.
20
3925
-
... More
Dismantling of 8 to 9 meter steel pole D.P. structure, including crane in store.
17
1910
-
... More
Dismantling of 11 KV ABC from line, including CR in store in rural area, including removing of all accessories.
2
24058
-
... More
Dismantling of A.B. Cable from line. INCLUDING Cu IN STORE OF FOLLOWING SIZES: A: 3 x 50MM2 + 16MM2 + 1 x 35MM2 B: 3 x 35MM2 + 16MM2 + 1 x 25MM2
2
12028
-
... More
Dismantling of A.B. cable from line. INCLUDING Cr. IN STORE OF FOLLOWING SIZES: A: 1 x 35MM2 + 1 x 25MM2
3
4812
-
... More
Installation of energy meter & MMB/SMC box with electrical wiring on transformer.
25
727
-
... More
Providing single-phase service connection with PVC 2.5/4.0 mm2 twin core cable from terminal pole to metering point, including fixing of meter with meter earthing. Complete work as per standard specification but excluding cost of materials.
50
397
-
... More
Providing three-phase four-wire service connection with PVC 4mm²/10mm² four-core cable from terminal pole to metering point, including fixing of meter with meter earthing. Complete work as per standard specification but excluding cost of materials.
50
546
-
... More
Carting of PSC pole at destination (above 5 km).
120
378
-
... More
Carting of RSJ pole at destination (above 5 km).
50
536
-
... More
Replacement of failed transformer & augmentation/deaugmentation of transformer (any capacity) including transportation & credit of old transformer at S/DN store.
8
1500
-
... More
M.S. Bolts & Nuts 65x16mm (2.5 x 5/8 INCH)
212
60
-
... More
M.S. Bolts & Nuts 180 x 16mm (7 x 5/8 INCH)
210
71
-
... More
M.S. Bolts & Nuts 300 x 16mm (12 x 5/8 INCH)
210
71
-
... More
Proving & Fixing of HEAT SHRINKABLE TYPE CABLE JOINTING KIT SUITABLE FOR 11 KV 1C X 95SQ MM AB CABLE FOR OUTDOOR TERMINATION APPLICATION
20
2300
-
... More
Proving & Fixing of HEAT SHRINKABLE TYPE CABLE JOINTING KIT SUITABLE FOR 11 KV 1C X 70SQ MM AB CABLE FOR OUTDOOR TERMINATION APPLICATION
16
2300
-
... More
Installation of earthing pits as per drawing attached here with by providing 100 mm inner diameter cast iron pipe of 13 mm thickness and 3000 mm length. Work includes fabrication and fixing of GI strips for earthing connections as per drawing attached. Excavated earth pit should be filled with a mixture of coal/charcoal, salt and sand up to the top. Further, this includes providing brick masonry chamber of size 450mm x 450mm and depth up to 1000 mm as per instructions of the Engineer in charge including light type CI cover and applying 12mm thick cement plaster in 1:3 inside and to all exposed faces up to 300 mm below foundation level, curing etc. complete. Extra earth should be removed away from the site or refilling earthing pits if required. All required material for this job such as CI pipe, cover with frame, salt, charcoal, sand, cement, gravel, bricks etc. to be supplied by the contractor. Required bolts, nuts, washers, number plates/painted plates also shall be arranged by the contractor. Tentative quantity of salt and charcoal shall be 2.50 cu.m. DRG. NO.:-GETCO/E/4s-025/P-011, Revision-3 is attached.
2
17698
-
... More
PETROLING HT/LT LINE- PER POLE
100
4
-
... More
Re-jumpering of HT/LT line for shackle pole
60
98
-
... More
Replacement of pole-mounted 1ph/3ph service connection box including reconnecting all connections.
50
244
-
... More
Cutting of tree branches obstructing HT/LT lines on one tree.
220
60
-
... More
Cutting of bigger size tree branches/whole tree obstructing HT/LT line.
31
477
-
... More
PIN binding of 11kV pin insulator
50
47
-
... More
PIN BINDING OF LT LINE PIN OR SHACKLE INSULATOR
25
47
-
... More
Replacement of 11 kV disc insulator
25
171
-
... More
Replacement of LT pin/shackle insulator
50
37
-
... More
REPLACEMENT OF V CROSS - ARMS
25
244
-
... More
REPLACEMENT OF TOP FITTING
15
60
-
... More
Replacement of LT cross-arms
15
79
-
... More
Providing a fuse or AB switch on DP (for one set) with fabrication and color-coded jumper, including proper alignment of AB switch contacts.
16
856
-
... More
Numbering the pole with paint by preparing a background of the required height. The surface should be one color and have lettering (2" & 3" ht) as directed by the in-charge engineer. The two colors should be selected to have contrast for proper readability. (Required colors to be provided by the contractor).
502
60
-
... More
Fixing of SMC (1-Ph) at consumer installation (including cost of fasteners).
50
98
-
... More
Fixing of SMC (3-Ph) at consumer installation (including cost of fasteners).
25
148
-
... More
Replacement of meter (1 PH) with wiring - Urban
100
58
-
... More
Replacement of meter (1-ph) with wiring - Rural
100
85
-
... More
Providing (Painting) Consumer No. on SMC/MMB - Rural
200
21
-
... More
Providing (Painting) Consumer No. on SMC/MMB - Urban
91
11
-
... More
Replacement of single-phase old service by new service including shortfall reels, insulators, egg insulators, nails, fixing fasteners, etc.
180
98
-
... More
Erection/Providing lightning arrestor
30
123
-
... More
REPAIRING/ADJUSTING TENSION OF EXISTING GUY/STAY SET INCLUDING
PROVIDING/REPLACEMENT OF STAY INSULATOR
40
183
-
... More
Replacement of old distribution box 200 kVA and above with making all connections, crimping of lugs, neutral, etc.
6
2203
-
... More
Replacement of old distribution box up to 100 KVA and above with making all connections, crimping of lugs, neutral, etc.
5
1224
-
... More
Providing line spacer between LT line conductor with binding.
50
37
-
... More
Refitting/replacement of lightning arrestors
51
37
-
... More
Thread burning of HT/LT line including cost of oil and bamboo etc.
50
73
-
... More
Refixing of V cross arm fitting in improper position.
10
73
-
... More
Refixing of top fitting improper position.
21
49
-
... More
RESTRINGING OF ACSR/AAC SPAN
35
111
-
... More
Re-stringing of 11kV A.B. cable (all sizes) HT ABC only.
28
330
-
... More
Re-stringing of dog conductor with new double pin binding.
19
148
-
... More
Supply of 11 kV indoor cable box for 95 sqmm XLPE cable.
5
1260
-
... More
Supply of 11 kV indoor cable box for 240 sqmm XLPE cable
5
877
-
... More
Supply of 11 kV indoor cable box for 185 sqmm XLPE cable
5
1445
-
... More
Supply of 11 kV outdoor cable box for 95 sqmm XLPE cable
5
1074
-
... More
Supply of 11 kV outdoor cable box for 185 sqmm XLPE cable
6
1073
-
... More
Supply of 11 kV outdoor cable box for 240 sqmm XLPE cable
6
1076
-
... More
Supply of 11kV straight through joint for 95 sqmm XLPE cable
2
3025
-
... More
Supply of 11kV straight through joint for 185 sqmm XLPE cable
3
2750
-
... More
Supply of 11kV straight through joint for 240 sqmm XLPE cable
3
2820
-
... More
Erection of cable joint for XLPE cable (straight/indoor/outdoor) urban area
7
2406
-
... More
Erection of cable joint for XLPE cable (straight/indoor/outdoor) rural area.
15
2922
-
... More
Replacement of 11KV PIN insulator by new pin insulator/composite pin insulator.
27
56
-
... More
Straightening of tilted PSC/RSJ pole at pin point.
24
284
-
... More
Straightening of tilted PSC/RSJ pole at tension point
24
329
-
... More
Straightening of tilted D.P. Set (PSC / Girder pole) etc. with refilling of stones, morum etc.
25
810
-
... More
Laying/Relaying of cable in cable trench and from ground level to pole structure for providing outdoor cable joints.
300
44
-
... More
Unbundaling of all size HT ABC
3
9008
-
... More
Stringing of all size HT ABC
3
4504
-
Evaluation Notes How It Works ?
Potential Partner
Select Your Requirements
Past BiddersThis list is curated from the bidders of the similar tenders in the past
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%