Gujarat Industrial Development Corporation Tender

... More
Search for the latest Gujarat tenders online related to civil works, road & transport, pipelines and more easily here on BidAssist. Here you can get any and every tender that is posted on the eProcurement Gujarat website, minus the clutter. No need for a tender ID, as on BidAssist, you can view any Gujarat tender by merely typing Gujarat in the search box.

Gujarat Industrial Development Corporation - GIDC Tender

Services
Machinery and Tools
Electrical and Electronics
GEM
Opening Date7 Apr 2025
Closing Date28 Apr 2025
Tender Amount₹ 2,34,11,385.67 
Notes
Download

AI Insights

Technical Capacity
... View More
The required prior work experience for the bidder is 5 years. The bidder must have successfully executed/completed similar services over the last three years. The requirements for similar completed services are: 1. Three similar completed services costing not less than 40% of the estimated cost, 2. Two similar completed services costing not less than 50% of the estimated cost, or 3. One similar completed service costing not less than 80% of the estimated cost. The estimated bid value is 23411385.67, which can be used to calculate the specific amounts for the similar completed services: 1. 40% of 23411385.67 = 9364554.27, 2. 50% of 23411385.67 = 11705693.34, 3. 80% of 23411385.67 = 18729108.53. Additionally, the minimum average annual turnover of the bidder for 3 years is 70 Lakh.

Costs

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Get the Best Price For TMT
Starting from
₹47,500/MT*
Gujarat

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
(C) 1.1/4"

10

378

-

... More
Supplying & erecting XLPE (IS:7098) (I)-88 ISI unarmoured copper cable 1.1KV grade to be erected as directed of following size. (J) 4 core 2.5 Sq. mm

120

166

-

... More
(D) 1.1/2"

10

419

-

... More
- do - but For 16A Plug and 16 amp switch with 2-4 sq.mm Cu. Wire with 2.5 sq.mm ( green) earthing wire from mcb d b board. with oval conduit /pvc casing capping double lock type erected flushed on wall/ceiling complete

10

730

-

... More
Carry out routine maintenance and servicing and testing up to 6300 Amp L.T. ACB with below defined scope and as per detailed technical specification: (1) Cleaning of dust,spider web ,foreign particles. Etc . (2) Removal of old grease with new grease for various parts.(3) Cleaning of various parts with CRC.(4) Check the tightness of all hardware (5)Checking of Spring Charging, Closing & Tripping mechanism (6) Measurement of IRV (7) Measuring of closing/tripping time by time testing kit (8) Measuring contact resistance by CRM kit.(9) Release testing by OEM recommended testing kit.

32

1556

-

... More
Point wiring for Looped Plug with 6A Modular type switch & 5 pin socket erected on PVC / Metallic box, single mounting base frame covered with textured / metallic front plate modules erected on / in wall / ceiling with following type accessories

20

241

-

... More
Repairing of existing outdoor LED light fixture(flood light/street light/bollard lights/decorative wall lights/landscape light etc as per sample )by suitable driver 4 kv,IP65 according to LED PCB as per requirement of following rating wattage capacity .(G) 50-80 watt capacity

50

886

-

... More
Providing & erecting following type of Modular Type Accessories with necessary connection. As desired by Engineer In charge

-

-

-

... More
Routine maintenance of Transformer in operating covering Insulation Resistance oil breakdown strength, reconditioning /replacement of silica gel, cleaning of transformer & topping up to of oil if required .(Oil will be provided departmentally or at extra cost.)

32

2177

-

... More
(D) Replacing wheel blower suitable for Split type A.C. machine.

5

334

-

... More
Solder less crimping type Aluminium lugs conforming to IS suitable for cable of following size evenly crimped with high pressure tool & connected to switchgear terminals with brass/cadmium plated nut bolts in an approved manner. (L) 400 Sq.mm.

50

110

-

... More
Supplying & erecting single phase approved make industrial exhaust fan suitable for medium duty ring mounted low noise operation suitable for medium duty having following dia size and maximum speed in RPM[E] 450 mm dia 1400 RPM

10

3937

-

... More
Supplying & erecting ABC powder type 'Ceasefire' type Fire extinguisher as per IS 13849 or 1Kg capacity with necessary clamp for erection on wall

10

720

-

... More
Supply, laying, testing & commissioning 1.1 kV grade, XLPE insulated, stranded Aluminium conductor, galvanised steel flat strip / round wire armoured, extruded PVC type ST2 sheathed, heavy duty cable (to be laid on wall surface with necessary clamps / in existing cable trench / cable trays / conduit / pipe sleeves at road crossing or floor as per site requirement) conforming to IS:7098 (Part-1) & IEC:60502 (Part-1) of following sizes:(m) 3 Core x 185 Sqmm

200

539

-

... More
Re insulating the HT / LT Copper / Alum. Coils of the 400 KVA capacity transformer

500

74

-

... More
Replacement of off load Tap changer of400 KVA Transformer

10

21782

-

... More
Replacing the burnt / unserviceable L.T side winding coils for transformer including rewinding, varnishing, vacuuming etc.

-

-

-

... More
Providing and erecting Approved make Three pole moulded case circuit breaker having breaking capacity ICU of 25K.A. at 415V having normal current rating upto 25A to 100A. with Fixed thermal & magnetic release suitable to work on A.C. supply 50c/s. with all internal connections, spreader tinned copper & complete erected in existing 16G.M.S. housing. ICS=100% of ICU only Cat III.

5

5355

-

... More
Providing & erecting 415 V MCB three Pole for Motor & Inductive Load (C Curve) having 10KA breaking capacity & confirms to IS :8828 in existing box having following capacity (b)40 Amp. Cat-III.

10

647

-

... More
(3) 6/16Amp. Universal socket

10

78

-

... More
Replacing L.T.Bushing all / other parts of the 400 KVA transformer.

20

437

-

... More
Providing and Erecting PCB Circuit of Outdor Unit for Inverter Type 3 Star rating Split A.C. Machine upto 2.2 TR Capacity.

5

7062

-

... More
Solder less crimping type Aluminium lugs conforming to IS suitable for cable of following size evenly crimped with high pressure tool & connected to switchgear terminals with brass/cadmium plated nut bolts in an approved manner. ( I ) 185 Sq.mm.

50

80

-

... More
Filtration of transformer oil as per I.S. for removal of moisture, carbon. Slurry etc. by means of circulating oil through vacuum pump from heating elements and filters to with stand the breaking strength of the oil above 40KV beyond one minute tested in oil testing Kit. (A) On Site

1400

7

-

... More
SITC of O Ring set 55 HP SCF type pump

24

2787

-

... More
Mains with 1.1 KV grade FRLS PVC insulated ISI marked stranded Copper conductor wire in following type of pipe to be erected in / on wall / ceiling with 2.5 sq. mm copper conductor FRLS PVC insulated stranded wire of green colour for earth continuity of following size with medium class Rigid PVC pipe and accessories 2 wire 4 sq. mm

250

107

-

... More
Providing and erecting Approved make Three pole moulded case circuit breaker having breaking capacity/strength ICU of 50K.A. and above at 415V. having normal current rating 250A. with variable thermal & magnetic release suitable to work on A.C. supply 50c/s. with all internal connections, spreader tinned copper & complete erected in existing 16G. M.S. housing. ICS=100% of ICU only Cat III.

4

22285

-

... More
Solder less crimping type Aluminium lugs conforming to IS suitable for cable of following size evenly crimped with high pressure tool & connected to switchgear terminals with brass/cadmium plated nut bolts in an approved manner. (D) 35/50 Sq.mm.

20

20

-

... More
Replacing the breather of the Transformer of400 KVA.

16

1089

-

... More
Supply of best quality well sorted Sevaliya gravel of size ranging from 4 mm to 6mm.

300

2049

-

... More
Supply, laying, testing & commissioning 1.1 kV grade, XLPE insulated, stranded Copper conductor, galvanised steel flat strip / round wire armoured, extruded PVC type ST2 sheathed, heavy duty cable (to be laid on wall surface with necessary clamps / in existing cable trench / cable trays / conduit / pipe sleeves at road crossing or floor as per site requirement) conforming to IS: 7098 (Part-1) & IEC: 60502 (Part-1) of following sizes: 3 Core x 25 Sqmm.

150

539

-

... More
Providing and erecting Air Cooled Condenser unit having face area of 0.235 Sq.Mtr. made out of 27 / 30 gauge copper tube and cover with Aluminium fins of12-13FPI . For Split AC Machine

-

-

-

... More
Supplying and erecting approved make panel mounting type Digital Voltmeter having 3 digits LED display, 0 to 750 AC Volts range erected on existing panel board with all connection, wiring etc .with manufacturers calibration certificate.

5

1275

-

... More
Providing and erecting Approved make Three pole moulded case circuit breaker having breaking capacity/strength ICU of 35K.A. at 415V.having normal current rating 125A. with Fixed thermal & magnetic release suitable to work on A.C. supply 50c/s. with all internal connections ,spreader tinned copper & complete erected in existing 16G.M.S.housing. ICS=100% of ICU only Cat III

15

6575

-

... More
Supply, laying, testing & commissioning 1.1 kV grade, XLPE insulated, stranded Copper conductor, galvanised steel flat strip / round wire armoured, extruded PVC type ST2 sheathed, heavy duty cable (to be laid on wall surface with necessary clamps / in existing cable trench / cable trays / conduit / pipe sleeves at road crossing or floor as per site requirement) conforming to IS: 7098 (Part-1) & IEC: 60502 (Part-1) of following sizes:3 Core x 4.0 Sqmm

400

114

-

... More
(5) Charges for 4th Routine Maintenance of wet Services with water or Chemical as per site requirement Services between 9th months to 12th Months from date of issue of work order.

6

267

-

... More
Disconnecting the cable connection and Providing straight joint with PVC mould using heat shrink /cast resin type epoxy compound Insulating material and making the joint complete using necessary in line connectors, hardener, earth continuity connection, spacers etc. and reconnecting the same & ensure the joint resistance within the limits as per IS.(B) 35 to 95 Sq. mm cable.

150

1550

-

... More
All inclusive comprehensive maintenance cost for the period of one year for the Split type Air-conditioning Unit of following Capacity (B) 1.5 Ton

-

-

-

... More
Supplying and erecting approved make oscillating type bracket fan A.C. 23OV. 50cy/s 400/450 mm sweep wall mounted with height adjustment and rotary tilting device complete with guard, flexible Core plug top complete erected with lead wires as directed. Cat II

10

2534

-

... More
(E) Replacing unserviceable running capacitor of 36 MFD to 50 MFD + 2 to 4 MFD Upto 2.5 H.P. compressor motor for A.C. machine upto 2 Ton..

5

609

-

... More
(B) For 1.5 TR A.C. Machine with 3/4 Row Deep coil

5

4006

-

... More
SITC of DE/ Lower Ball Bearing 55 HP SCF type pump

24

10302

-

... More
Point wiring for Individual Plug with & earth wire of 1.5 sq.mm (Green) both are of ISI marked 1.1 KV grade FRLS PVC insulated multi strand copper wires up to 10 mtr length, in below type of pipe erected complete with Modular type switch & 5 pin Plug erected on PVC / Metallic/Wooden box covered with appropriate front plate modules erected on / in wall / ceiling as per pipe erected with following type of accessories.For 6A Plug with 2-1.5 sq.mm Cu. Wire with medium class Rigid PVC pipe and accessories

30

445

-

... More
Supplying and erecting approved make panel mounting type Digital Ammeter having 3 digits LED display, external CT operated, calibrated for 0 to 1000 Amps suitable to operate on 500 Volt AC , erected on existing panel board with all connection, wiring etc .with manufacturers calibration certificate.

6

1558

-

... More
Supplying and erecting LED street light / Flood light fittings with High power White LEDs wattage of 3 Watt and above assembled on single MCPCB, efficiency more than 130 lm/w and corrosion free High pressure die cast aluminum housing with smooth finish powder coated and heat sink extruded aluminium with diffuser and Polycarbonate optics/ lenses, with toughened glass with company mark/name engraved or embossed 160 to 270 V,Power Factor more than 0.95, THD 10 %, CCT 3000 K to 5700K,Uniformity ratio 0.45, Luminaire efficacy 100 lumens/watt . LED driver efficiency 85 %.( fittings required LM-79 & LM-80 certificates)(B) Flood Light (IP-65), Surge protection -4KV integral and ,Light must have 440VAC line supply with over-voltage protection. (iii) above 60 to 90 watts

50

5976

-

... More
(5) LAN cable connector with ferule

10

35

-

... More
(2) Charges for 1st Routine Maintenance of Dry Services between date of commencement to 3rd Months from date of issue of work order.

6

144

-

... More
Providing and erecting XLPE (IS:7098)(I)-88 ISI armoured cable multistrand Copper conductor for 1.1KV. To be laid on wall with necessary clamps or in existing trench/pipe at road crossing or floor of following size of cables. (F)3x 1/2core -120Sq.mm (70 Sq.mm 1/2core)..

100

6418

-

... More
Measurement of earthing resistance by loop test with authorized test report after isolating & cleaning joint.

60

363

-

... More
(1) 6 Amp. SP one way switch

10

26

-

... More
Supplying & erecting approved make Power Factor Meter 150mm dia flush/projection type/ balanced & unbalanced load to work with appropriately provided CT’s 100/5A to 400/5A ratio & other accessories complete erected in M.S. box & connected to the circuit by means of PVC copper Core leads.

3

5102

-

... More
providing and erecting Miniature circuit breaker single pole 6A to 25A suitable to operate on 240 V A.C. system and having breaking capacity 10 KA to be erected in existing box. confirming to IS 8828/1996 with ISI Mark Cat-III.

40

112

-

... More
Replacing condenser for ceiling fan/ Exhaust Fan / Pedestal Fan / Table Fan / Cabin Fan {Credit of D.M. retained by Agency.}

20

64

-

... More
Replacement of defective isolation/service valves of outdoor unit of Split air conditioner up to 2.0 TR capacity.

5

463

-

... More
Replacing the valve of the Transformer of rating capacity 250 / 315 / 500 / 750 / 1000 /1250 KVA of following size

-

-

-

... More
Providing and erecting of ISI mark CI D/F Butterfly valves as per IS: 13095 (Latest Edition) of following class and 200 mm diameter including all taxes, insurance, transportation, freight charges, octroi, inspection charges, loading, unloading, conveyance to departmetal stores, stacking etc. complete. PN-1.6 IS 13095 with ISI mark with incluging cost of all labour, jointing material including nut bolts and giving satisfactory hydraulic testing, etc. complete.

5

6926

-

... More
Solder less crimping type Aluminium lugs conforming to IS suitable for cable of following size evenly crimped with high pressure tool & connected to switchgear terminals with brass/cadmium plated nut bolts in an approved manner. (A) 1.5/ 2.5/4/6 Sq.mm

30

6

-

... More
SITC of Primary/ Lower Mechanical Seal 55 HP SCF type pump

24

8019

-

... More
Providing & erecting L.T.Current Transformer with bar primary 50/5 to 1000/5 ratio 15VA burden erected in existing CRCA box duly secured with insulating materials connected to the meter.

24

274

-

... More
Casting of transformer plinth / foundation including oil soak pit (where required) in situ reinforced cement concrete in M 20 using granite, quartzite trap metal of size 6 mm to 20 mm for RCC work including providing of 53 grade cement & Fe 415 grade TMT bars, scaffolding, centering, form work, curing etc. complete. RCC plinth / foundation for transformer of capacity 315 & ≤ 630 KVA. up to 33 kV/OCTC Transformer Rating- 400 kVA Plinth Dimensions: 1500x1500x 1500.

4

35350

-

... More
Providing and erecting of ISI mark CI D/F Sluice valves as per IS: 14846 (Latest Edition) of following class and 200 mm diameter including all taxes, insurance, transportation, freight charges, octroi, inspection charges, loading, unloading, conveyance to departmetal stores, stacking etc. complete. PN-1.6 with hand wheel/Cap operated (PD type short body) with incluging cost of all labour, jointing material including nut bolts and giving satisfactory hydraulic testing, etc. complete.

5

11147

-

... More
Supply, laying, testing & commissioning 1.1 kV grade, XLPE insulated, stranded Copper conductor, galvanised steel flat strip / round wire armoured, extruded PVC type ST2 sheathed, heavy duty cable (to be laid on wall surface with necessary clamps / in existing cable trench / cable trays / conduit / pipe sleeves at road crossing or floor as per site requirement) conforming to IS: 7098 (Part-1) & IEC: 60502 (Part-1) of following sizes:3 Core x 6.0 Sqmm

150

154

-

... More
SITC of Secondary/ Upper Mechanical Seal 55 HP SCF type pump

24

6817

-

... More
(2) 16 Amp. SP one way switch

10

49

-

... More
Providing & erecting 415V MCB Four Pole Switch for Lighting Load (B curve) having 10KA breaking capacity & confirms to IS :8828 in existing box having following capacity (a) 6 to 32 Amp. Cat-III.

10

578

-

... More
Supplying & fixing Steel Chequered Plate having 12 mm thickness, duly painted with two coats of black Japan colour. (Average Wt 200.3 kg / Sq.Mtr)

100

4899

-

... More
Replacing old & unserviceable gasket bushing of L.T. for the 400 KVA capacity Transformer

10

147

-

... More
Supplying and erecting triple pole & neutral 440V / 500V panel mounting Copper Busbars with four equal Nos. of electrolyte bus having current density not more than 1.6 Amp. / sq.mm (Rated current / cross section area) duly wrapped with colour insulating tape for phase sequence of following current carrying capacity, erected with necessary bus bar supports /insulators, main cable socket to each bar, erected in existing cubical panel with necessary connections.(F) Suitable for 800 Amp. capacity .

4

13199

-

... More
Replacing old & unserviceable gasket bushing of H.T. for the 400 KVA capacity Transformer

10

205

-

... More
Replacing H.T Bushing metal parts of 400 KVA Transformer by new one.

20

226

-

... More
(A) For Copper Coils

500

437

-

... More
Do the Motor Rewinding of 55 HP SCF type pump

24

32825

-

... More
Replacing the burnt unserviceable H.T. side winding coils for the transformer including rewinding, varnishing, vacuuming etc.

-

-

-

... More
SITC of Oil for Mechanical Seal 55 HP SCF type pump

24

242

-

... More
Do the routine as well as preventive maintenace with spares of 3.0 tonnes x 9 mtr. lift Single girder type fully electrically operated E.O.T crane with electrically operated Hoist class - II , geared travelling trolly with seven mtr. lift

8

111958

-

... More
Supplying & erecting carbondioxide (CO2) fire extinguisher user of following capacity with necessary clamps made from 50x6mm M.S.Flat with nut & bolts grouted in wall complete. [A] For 4.5 Kg Capacity

10

5587

-

... More
(B)For Aluminium Coils

500

220

-

... More
Providing pair of rubber hand gloves suitable for working on 11 KV/22 KV supply.

10

181

-

... More
To carry out maintenance of installed VFD drive which includes preventive as well as breakdown maintenance of installed Variable Frequency Drives (VFDs) to ensure their optimal performance and longevity as per detailed techinical specification. The scope of work includes periodic inspection, testing, cleaning, lubrication, and servicing along with prompt breakdown maintenance to minimize downtime. Replacement of defective or worn-out components using genuine spare parts ensuring uninterrupted operation is also included in the scope of work.

110

19171

-

... More
(3) Charges for 2nd Routine Maintenance of wet Services with water or Chemical as per site requirement Services between 3rd months to 6th Months from date of issue of work order.

6

267

-

... More
Replacement of defective Oscillating motor of Split air conditioner up to 2.0 TR capacity.

5

600

-

... More
Supplying and erecting Ammeter / Voltmeter selector switch for 3 phase AC Supply 500 V on existing panel board with necessary connections.

13

317

-

... More
Providing and erecting required size HOT deep Galvanised iron strip for earthing of H.T. , OCB/ ACB/ Transformer LT panel board, Motors etc. using proper clamp.

300

77

-

... More
Solder less crimping type Copper lugs conforming to IS suitable for cable of following size evenly crimped with high pressure tool & connected to switchgear terminals with brass/cadmium plated nut bolts in an approved manner. (A) 1.5/2.5 to 6 Sq.mm

50

8

-

... More
Providing & fitting heat shrink cable termination / jointing kits for 6.6 kV (UE) / 11 kV (E) grade XLPE insulated cable including necessary earth connectivity connection, material & consummables making the termination/ joint complete ensuring the joint resistance is within the permissble limit as per IS, of following types & sizes: 3Cx 240 to 400 Sq.mm Outdoor Terminations Kit suitable for Cable Terminations / Jointing Kits for 11 kV (UE) grade XLPE Cable

30

11601

-

... More
(4) Charges for 3rd Routine Maintenance of Dry Services between 6th months to 9th Months from date of issue of work order.

6

144

-

... More
Providing & erecting 415 V MCB three Pole for Motor & Inductive Load (C Curve) having 10KA breaking capacity & confirms to IS :8828 in existing box having following capacity (a) 6 to 32 Amp. Cat-III.

25

587

-

... More
Supplying & erecting directly operated single phasing preventer complete erected and connected to supply up to 45 Amp. Range.

6

1078

-

... More
Supply, laying, testing & commissioning 1.1 kV grade, XLPE insulated, stranded Copper conductor, galvanised steel flat strip / round wire armoured, extruded PVC type ST2 sheathed, heavy duty cable (to be laid on wall surface with necessary clamps / in existing cable trench / cable trays / conduit / pipe sleeves at road crossing or floor as per site requirement) conforming to IS: 7098 (Part-1) & IEC: 60502 (Part-1) of following sizes:3 Core x 2.5 Sqmm -

150

86

-

... More
Supplying stand first AID box with antiseptic cream, medicine for use on wounds due burn, crepe bandage, gauge bandage,medicated ready to use bandage (Band-aid) adhesive tape for medicinal user, Scissors, anti-septic solution (Savlonor similar) etc.(All above content shall be of standard makes)

4

254

-

... More
Providing & erecting High Voltage Danger Notice Board sticker as per language suggested by engineer incharge of standard size-as per IS 2551

10

35

-

... More
Supplying FIRE bucket round bottom of 9 litres capacity made out of 24 gauge G.I. sheet with extra handle at bottom duly painted white inside and Red outside with FIRE mark, filled with dry-sand and kept on existing stand provided or hung on wall hook.

8

181

-

... More
Testing of transformer oil by calibrated instrument for dielectric breakdown strength with test report

16

363

-

... More
To provide the Skilled Pump Operator (Zone-II)for necessary operation of existing Panel and pumping Machinery at Pumping statioon 1 &2,GIDC,Sanand-2

24

120472

-

... More
Rewinding of 2900 RPM, 25OV. Fan Motor of air circulators by using supper enamelled copper wire and over hauling & put in working order with original speed with guarantee for one year including transportation from site & back including {Credit of D.M. retained by Agency.}

10

488

-

... More
SITC of Grease 55 HP SCF type pump

24

2828

-

... More
To provide the Skilled Electrician (Zone-II)for necessary Maintenance/ repair/ replacement of existing electrical appliances/apparatus/equipment at Pumping statioon 1 &2,GIDC,Sanand-2

24

60236

-

... More
providing and erecting Approved make RCCBs conforming to IS: 12640 and having sensitivity of 30 mA and Short Circuit withstand capacity of 10 KA and suitable for operation on single phase 240 V,50Hz. having characteristic of quick action & tripping with all advance feature & do not incorporate any electronic component. for following Max. rating erected as directed (i) 25 Amps.DP Cat-III.

10

1969

-

... More
Point wiring for Light / Bell with 2-1.5 sq.mm & earthwire of 1.5 sq.mm (Green) both are of ISI marked 1.1 KV grade FRLS PVC insulated multistrand copper wires, in following type of pipe to be erected concealed in/ on surface on wall/ceiling complete with 6A Modular type switch / bell push & accessories and earth continuity of following type, erected on PVC / Metallic box, single mounting base frame covered with textured/metallic front plate modules erected on / in wall / ceiling as per pipe erected, with necessary Lamp holder/ceiling rose / H.D.Connector as directed with medium class Rigid PVC pipe and accessories (Cat-III)

30

419

-

... More
SITC of NDE /Upper Ball Bearing of 55 HP SCF type pump

24

1010

-

... More
Replacing H.T. bushing all other parts of 400 KVA Transformer.

20

132

-

... More
Replacing old and unserviceable gasket of Top cover plate of Transformer having 400 KVA capacity.

10

377

-

... More
Drying the repaired transformer with appropriate heat air of 400 KVAcapacity transformer.

10

1306

-

... More
Rewinding of Any fan by using supper enamelled copper wire and over hauling and putting in working order with original speed with guarantee for one year including credit of D.M. retained by Agency.

20

334

-

... More
Transformer oil having good resistance to high electrical stress, high di-electrics trength (50KV) low viscosity, low pour point, high flash point and excellent thermal properties for efficient heat transfer and cooling as per I.S.335 -1972.

1400

77

-

... More
providing and erecting Approved make RCCBs conforming to IS: 12640 and having sensitivity of 30 mA and Short Circuit withstand capacity of 10 KA and suitable for operation on single phase 240 V,50Hz. having characteristic of quick action & tripping with all advance feature & do not incorporate any electronic component. for following Max. rating erected as directed (iii)63 Amp. Cat-III.

10

2654

-

... More
Do the routine maintenance/preventive maintenance along with Digital Video Recorder (DVR)/Network Video Recorder [NVR], Hard Drive, Monitor, all types of cable and accessaries insatalled at PS No.-1&2 ,GIDC Sanand for Security purpose. The price is included Comprehencive Maintenance and servicing, checking of all the installed CCTV of the system. The servicing should be carry out in case of fault, technician should be attend immediately. The replacement of spares if any shall be done with in stipulated time as per instruction of Engineer in charge. No extra price will be provided for replaccement of spares. Technician shall be attend after in case of fault for checking of Proper functioning, proper working of whole system parts, cleaning of lens camera, Setting of view points as well as after service trial run for entire CCTV System. And report the incharge engineer in prescribed format provided by department.

64

4599

-

... More
Providing and erecting Approved make Three pole moulded case circuit breaker having breaking capacity/strength ICU of 50K.A and above at 415V having Normal current rating 400A. with variable Thermal & magnetic release suitable to work on A.C. supply 50c/s. With all internal connections, spreadertinned copper& complete erected in existing 16G.M.S. housing. ICS=100% of ICU only Cat III.

10

25228

-

... More
Replacing the bearing/ bushing of Table fan Pedestal Fan / Exhaust Fan and putting the fan in working order including {Credit of D.M. retained by Agency.}(b) Bushing rubber, ring, washers

20

51

-

... More
Removing the laminated core plate of the 400 KVA capacity Transformer.

10

1089

-

... More
Design, Supply, Installation, Testing, Commissioning of Bourdon Type Pressure Gauge, ±1% accuracy, Direct bottom 1/2" NPT (M) process connection, IP 67, Glycerine filled, SS304 Case with Bayonet Type Bezel, SS316 L Bourdon Tube, SS 316 Movement material, Aluminium dial with black graduation on white background, Micro Zero adjustable pointer, neoprene gasket, Blow out disc, shatter proof glass, SS tag plate etc as per IS 3624. 100 mm Dial Size 0 to 21 Kg/cm2

5

1039

-

... More
Replacing H.T. bushing of 400 KVAtransformer by new one.

20

165

-

... More
Outside painting of Transformer for the 400 KVA capacity

8

1074

-

... More
SITC of SS Fasteners 55 HP SCF type pump

24

3434

-

... More
Dismantling and refitting of transformer including cost of required new M.S. bolts For 400 KVA capacity transformer

20

1525

-

... More
Servicing, overhauling, cleaning of the panel board LT by liquid EPNF-065™ technology, after scanning the single side of panel by thermal scanning technology. Thermal scanning technology includes measuring temperature before and after servicing by each& every space of the panel board. Oneside of panel must be cleaned by Air Compressor Capacity 2.5to3.5 HP Motor, 1or3 phase, 230v, Air tank having capacity approx 50kg with latest moisture filter, spray gun having EPNF-065™ liquid. The work having time constraints of 2to5 minutes single side of the panel. After finishing work agency has to provide 3 photographs or to provide 2 minutes video. Dust or any waste material must be collected by agency in the bottom of panel board by nonwoven fabrics material or any scientific materiel. Agency has to carryout work in presence of site in charge engineer & to complete the work as per site incharge engineer.

63.84

4123

-

... More
Replacing L.T. bushing of 400 KVA capacity Transformer

20

73

-

... More
(A) For Copper Coils

500

401

-

... More
(B)For Aluminium coils

500

238

-

... More
Replacing the bearing/ bushing of Table fan Pedestal Fan / Exhaust Fan and putting the fan in working order including {Credit of D.M. retained by Agency.} (a) Bearing

20

85

-

... More
Solder less crimping type Copper lugs conforming to IS suitable for cable of following size evenly crimped with high pressure tool & connected to switchgear terminals with brass/cadmium plated nut bolts in an approved manner. (H) 120 Sq.mm.

50

56

-

... More
Providing and erecting of ISI mark CI D/F Reflux valves as per IS: 5312 (Latest Edition) of following class and 200 mm diameter including all taxes, insurance, transportation, freight charges, octroi, inspection charges, loading, unloading, conveyance to departmetal stores, stacking etc. complete. PN-1.6 IS 5312 with ISI mark with incluging cost of all labour, jointing material including nut bolts and giving satisfactory hydraulic testing, etc. complete.

5

17486

-

... More
Providing and Erecting PCB Circuit of Indor Unit for Inverter Type 3 Star rating Split A.C. Machine upto 2.2 TR Capacity.

5

3639

-

... More
Removing washer ring for the coils of the 400 KVA capacity Transformer

10

74

-

... More
Repairing of off load Tap changer of 400 KVATransformer.

10

813

-

... More
Mains with 1.1 KV grade FRLS PVC insulated ISI marked stranded Copper conductor wire in following type of pipe to be erected concealed in /flushed on wall/ceiling, with 1.5 sq. mm copper conductor FRLS PVC insulated stranded wire of green colour for earth continuity of following size with medium class Rigid PVC pipe and accessories 2 wire 2.5 sq. mm

350

78

-

... More
Replacement of defective Oscillating louvers of Split air conditioner up to 2.0 TR capacity.

5

916

-

... More
Supply, laying, testing & commissioning of 1.1 kV grade, XLPE insulated, stranded Copper conductor, galvanised steel flat strip / round wire armoured, extruded PVC type ST2 sheathed, heavy duty cable (to be laid on wall surface with necessary clamps / in existing cable trench / cable trays / conduit / pipe sleeves at road crossing or floor as per site requirement) conforming to IS: 7098 (Part-1) & IEC: 60502 (Part-1) of following sizes:3.5 Core x 50 Sqmm-

150

1166

-

... More
(B) 1"

10

510

-

... More
Removing the installed Ceiling fan / Exhaust Fan for servicing / repairing from ceiling and reinstalling the same after making in working condition.

20

43

-

... More
providing and erecting Approved make standard manually operated fixed type 3 Pole Air circuit breaker. Having 50 kA breaking capacity ,Vsr=690 v, Ui=1kv ,impulse voltage=12 kv with ICU=ICS=ICW (1 sec), with following type of relay and accessories. (2) with microprocessor Release with over load, short circuit, earth fault protection (L.S.I.G.) and metering display in modular design with LED display and Test Trip button facility, CTs and auxiliary contacts, of following current ratings(B) 800Amp Cat III

6

68364

-

... More
(4) 6 A socket

10

40

-

... More
Dismentaling and Assembly Charges 55 HP SCF type pump

24

11736

-

... More
Do the routine as well as preventive maintenace of the online Un-interruptible Power Supply system with IGBT Based rectifer and Inverter & sealed maintenance free batteries. Single phase Input and Single Phase output with Inbuilt Isolation transformer with with battery, over under voltage output with over load & short circuit protection equipment. (A) 1 KVA with 1Hr Backup.

4

4964

-

... More
(A) 3/4"

10

246

-

... More
Replacing the oil level glass of the 400 KVA by new one

20

67

-

... More
Supplying and erecting floor mounting stand for keeping four nos.of FIRE buckets comprising 1500mm in length,900mm height frame made out of 30mmX30mmX4mm angle iron with cross supports for legs, welded with 4 hooks and duly painted with one coat of red lead and two coats of approved enamelled silver paint.

2

799

-

... More
Supplying and erecting approved make suitable panel indicator LED type lamp (for RYB), lens cover, complete erected with necessary connections.

40

43

-

... More
Replacement of defective remote control hand set with new battery cells. (B) Split Unit -OEM Make

5

1694

-

... More
To provide the Un-Skilled Helper (Zone-II) for necessary operation of existing Panel and pumping Machinery at Pumping statioon 1 &2,GIDC,Sanand-2

24

115382

-

... More
Providing & fitting heat shrink cable termination / jointing kits for 6.6 kV (UE) / 11 kV (E) grade XLPE insulated cable including necessary earth connectivity connection, material & consummables making the termination/ joint complete ensuring the joint resistance is within the permissble limit as per IS, of following types & sizes: 3Cx 400 to 500 Sq.mm Indoor Terminations Kit suitable for Cable Terminations / Jointing Kits for 11 kV (UE) grade XLPE Cable

30

7457

-

... More
Disconnecting the cable connection and Providing straight joint with PVC mould using heat shrink /cast resin type epoxy compound Insulating material and making the joint complete using necessary in line connectors, hardener, earth continuity connection, spacers etc. and reconnecting the same & ensure the joint resistance within the limits as per IS.(C) 120 to 300 Sq. mm cable.

10

2654

-

... More
Replacing old and unserviceable Indoor unit Fan Blower motor by new 12 watt to 30 Watt capacity suitable for Split AC machine.

5

1087

-

... More
Replacing L.T.Bushing metal parts of 400 KVA Transformer.

20

314

-

... More
Supplying and erecting LED indoor fittings with LEDs of wattage 0.2 Watt to 0.5 Watt assembled on single MCPCB, with housing used as a heat sink shall be made of thick sheet Steel conforming to IS: 513/CRCA/ aluminium die cast powder coated and high U.V. & corrosion resistance with diffuser with company mark/name 160V to 270V, Power Factor more than 0.9, THD 15%, CCT 3000 K to 6500K, Luminaire efficacy 85 lumens/watt ,LED LED driver efficiency 85 % ( fitting required LM-79 & LM-80 Certificates)(A) Tube Light with integral driver (v) 36-40 Watts, Surge - 2KV,IP-20, conventional 4 feet Cat-III.

150

535

-

... More
Providing & erecting 415 V MCB Four Pole for Motor & Inductive Load (C Curve) having 10KA breaking capacity & confirms to IS :8828 in existing box having following capacity (c)63 Amp. Cat-III.

10

737

-

... More
Providing and erecting XLPE(IS:7098)(I)-88 ISI armoured cable multistrand Aluminium conductor for 1.1 KV. to be laid on wall with necessary clamps or in existing trench / pipe of following size of cables (K) 3x 1/2core 400 Sq.mm (185 Sq.mm1/2core).

210

1738

-

... More
Inside painting of400 KVA KVA transformer.

8

988

-

... More
Insulating the HT/LT copper Aluminium coils of transformer.

500

161

-

... More
Supply, installation, testing & commissioning heavy duty APP type capacitor unit, vacuum impregnated with non-PCB / non toxic oil, internally delta connected with built in internal fuses complete with discharge resistances & terminal cover, rated for 440 V AC, 3 Phase, 50 Hz as per IS: 13585 Part-1. APP type Capacitor

80

287

-

... More
Providing & erecting 415 V MCB three Pole for Motor & Inductive Load (C Curve) having 10KA breaking capacity & confirms to IS :8828 in existing box having following capacity ( C)63 Amp. Cat-III.

10

716

-



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.