Border Security Force Tender

Search for the latest Gujarat tenders online related to civil works, road & transport, pipelines and more easily here on BidAssist. Here you can get any and every tender that is posted on the eProcurement Gujarat website, minus the clutter. No need for a tender ID, as on BidAssist, you can view any Gujarat tender by merely typing Gujarat in the search box.

Border Security Force - BSF Tender

Works
Civil And Construction
Eprocure
Opening Date28 Dec 2024
Closing Date3 Feb 2025
Tender AmountRefer Documents 
Notes
Download

Costs

Summary

Dry Dock Repair Work Of Mb Jwala

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
All railing and chain to be checked and defective /damaged portion to be replaced.

1

-

-

... More
Escape hatch of Accommodation top, wheel house top and steering compartment to be replaced (03) and engine room escape hatch rubber sealing to be replaced.

1

-

-

... More
Shore supply socket to be replaced-01 No

1

-

-

... More
Manual bilge pump to be replaced-01 No

1

-

-

... More
Fuel tank top FRP cap in deck to be replaced -03 Nos

1

-

-

... More
Fire hose box to be replaced.

1

-

-

... More
FRP sheet canopy to be provided in deck. (Approx. size 11ft X 12ft)

1

-

-

... More
All Zinc anodes of hull are required to be replaced with new one and Zink anode bolts of both Main engine to be replaced.

1

-

-

... More
Fuel filling hose leakage required to be replaced (4feet approx.)

1

-

-

... More
Front deck crew seat to be replaced.(3ft X 1.5ft size) Qty-01 No

1

-

-

... More
Fuel tank ventilation deck side to be replaced. Qty -02 Nos

1

-

-

... More
D. D. Fire pump with branded company prefer Honda make, with suction hose fitted with non-returning foot valve and discharge hose pipe brass ends and nozzle required to be replaced.

1

-

-

... More
Accommodation natural vents required to be overhauled-02 nos

1

-

-

... More
ANCHORING SYSTEM ) i)S S 316 grade Anchor chain 35 Mtr (10mm) is required to be replaced-01 No

1

-

-

... More
ii) Anchor windlass DP31024D manual not working required to repaired -01 No

1

-

-

... More
Following Ropes are required to be replaced with new. i) 18 mm Nylon Rope 150 mtr ii)14 mm dia Nylon Rope 100 mtr iii) 12mm dia Nylon Rope 100 mtr

1

-

-

... More
CABIN i)Pilot, passenger seat, foam & Rexene to be replaced.(Pilot seat- 01 No, Passenger- 04 Nos)

1

-

-

... More
ii)Front side both window glass and port side window glass to be replaced (Front glass-02 Nos, Port side glass-01 No)

1

-

-

... More
WINDOW CURTAIN i) All side window glasses curtain with Curtain holder required to be replaced-10 Nos

1

-

-

... More
WIPER i) Wiper, Wiper motor along with blades and holder to be replaced- 02 Nos

1

-

-

... More
ii) Wiper water spray nozzle and wiper water bottle required to be replaced-02 Nos

1

-

-

... More
Horn to be replaced. Qty - 01 No

1

-

-

... More
(B) MAIN ENGINE :-Main Engine Make and Types- 2x Cummins, QSB 6.7, 1NT, Power: 473 HP 3000 RPM. Both the main engine required servicing as per run hrs covered. Other maintenance of main engines and its system to be carried out as per the schedules prescribed by OEM/ Manufacturer. ( Engine Srl No. 74137527 (STBD) & 74136075 (PORT) Engine Model No.-QSB 6.7 INT 473 HP Hours (PORT) - 911.11 Hrs, (STBD) - 911.11 Hrs as on 07.05.2024 ). i) Both main engine require ‘D’ check as per OEM schedule by the authorized service agencies of Cummins Engine.

1

-

-

... More
Both main engine and gear box mounting and vibration pad required to be replaced.

1

-

-

... More
Both main engine Heat exchanger, Inter cooler and oil cooler required servicing and pressure test. If required to be changed.

1

-

-

... More
Battery of both main engines and emergency battery 200Ah Qty 06 Nos and DG set-115Ah Qty-01No (EXIDE MAKE) required to be replaced

1

-

-

... More
Fuel digital display not working required to be repaired.

1

-

-

... More
Both main engine & gear box hoses/flexible pipes to be replaced.

1

-

-

... More
Both main engine exhaust manifold hose with clamp required to be replaced.

1

-

-

... More
Belts of main engine required to be replaced.

1

-

-

... More
Turbocharger required to be serviced.

1

-

-

... More
Injector (calibration and pressure testing)

1

-

-

... More
Silencer pipes /flanges/mufflers to be replaced. (Tiller deck)

1

-

-

... More
Fresh water pump kit required to be replaced.

1

-

-

... More
Sea water cooling pump required to be replaced.

1

-

-

... More
ENGINE ROOM All sea water pipe line required cleaning by chemical and pressure test. If any found damage/poor condition required to be replaced

1

-

-

... More
Bilge pump /fire pump Qty 01 no required to be serviced.

1

-

-

... More
Bilge/fire pipe line with valve required servicing/cleaning by chemical and pressure test, if any found damage/poor condition required to be replaced.

1

-

-

... More
Smoke detector and heat detector to be checked and to be made functional.

1

-

-

... More
01 set sea chest non returning valves required replacement.

1

-

-

... More
All valves required to be checked and tested and valve spindle required to be replaced.

1

-

-

... More
Fuel quick closing valve to be serviced and defective parts to be replaced.

1

-

-

... More
Machinery room motor and blowers to be serviced -02 nos

1

-

-

... More
Main engine driven fire and bilge pump to be overhauled- 01 no

1

-

-

... More
Battery charger not working required to be serviced-01 no (Blue smart Charger-20A)

1

-

-

... More
DG SET (FISCHER PANDA 8 KVA) 8 KVA DG set to be overhauled and servicing to be done from authorized dealer and if any defective parts to be replaced.

1

-

-

... More
DG set sea water cooling pump and strainer with hose pipe line required to be replaced-01 no

1

-

-

... More
FIRE ALARM All fire alarm system to be checked and to be made operational.

1

-

-

... More
GEAR BOX ( TWIN DISC MG5065A) Gear box maintenance as per OEM instructions to be carried out. Any parts replaced should be OEM supply.02 nos

1

-

-

... More
PROPULSION UNIT Both Propeller shaft to be replaced with proper alignment.

1

-

-

... More
Both Propeller required to be replaced with proper alignment.

1

-

-

... More
Seal of Both Rudder shaft required to be replaced and rudder base to be checked and if required to be repair.

1

-

-

... More
Both ‘P’ bracket required refitted with proper alignment.

1

-

-

... More
Both ‘P’ bracket bush and gallon bush required to be replaced.

1

-

-

... More
Complete unit alignment with gear box, engine, propeller shaft and propeller.

1

-

-

... More
SPECIAL EQUIPMENT SART to be serviced and its battery to be replaced with new one and to be made operational. (Qty-01 No)

1

-

-

... More
Dry and wet bulb temperature scale to be replaced-01 no.

1

-

-

... More
NAVIGATION LIGHTS All navigation lights Port side-Red ,STBD side-Green and all-round/ mast light (Total - 03 Nos) to be replaced.

1

-

-

... More
Side LED light to be replaced -05 Nos

1

-

-

... More
Police siren lights to be replaced with new one.- 01 No

1

-

-

... More
LIFE SAVING EQUIPMENT Life raft 10 men capacity 02 Nos required to be serviced from authorized service center and to be installed in suitable place as per recommendation of IRS.

1

-

-

... More
Hazardous duty life jackets with white lights and whistle required to be replaced. - 06 Nos

1

-

-

... More
Life buoys SOLAS with light approved with 30 mtr life lines to be replaced – 04 Nos

1

-

-

... More
Life jacket with white lights and whistle required to be replaced. -14 Nos

1

-

-

... More
AIS system required to be serviced.

1

-

-

... More
FIRE FIGHTING EQUIPMENTS: 6.5 kg CO2 type Fire extinguisher to be replaced -01 No

1

-

-

... More
6 kg DCP type Fire extinguisher to be replaced -01 No

1

-

-

... More
9 Ltr Mechanical foam type Fire extinguisher to be replaced -04 Nos

1

-

-

... More
Fire hydrant, hose and nozzle of engine room fire pump required to be replaced -01 no.

1

-

-

... More
TANKS Fresh water tank is required cleaning and tested for leaks-01 no (700 Ltr cap)

1

-

-

... More
Fuel tank to be cleaned and checked for leak and tested for leaks-02 nos (1000 Ltr cap each))

1

-

-

... More
TOILET Toilet door lock to be replaced with new one. Qty-01 No

1

-

-

... More
Western Commode to be replaced. Qty-01 No

1

-

-

... More
AIR CONDITIONING & VENTILATIONS Air conditioning unit required servicing/overhauling and defective item to be replaced.

1

-

-

... More
Refilling of refrigeration gas.

1

-

-

... More
Operating panel board check and defective items repair/replace.

1

-

-

... More
AC cooling pump required to be serviced

1

-

-

... More
MISCELLANEOUS 06 Nos Fans to be replaced/repaired

1

-

-

... More
Accommodation room sleeping seats cushion with cover to be replaced. Qty- 04 Nos

1

-

-

... More
Bed sheets and pillows required to be replaced. Qty- 04 Nos

1

-

-

... More
Visual/manual fuel pipe measuring system may be installed outside the fuel tank to check the fuel level.

1

-

-

... More
ELECTRICAL SIDE Insulation resistance (megher test) and OEM recommended preventive maintenance to be carried out and the electrical items should be made operational/functional. All electronic components, controls and wiring used on engine and the boats are to be marine version complying with IP 65 rating.

1

-

-

... More
All fuse to be replaced

1

-

-

... More
PAINTING. Under Water Hull Surface Cleaning And Painting (It is suggested that FRP addition based Marine paint required to be utilized). Pen Guard HB Primer (Epoxy Primer )01 Coat- 100 Micron (DFT) Safe Guard Universal ES Grey Tie Coat- 01 Coat 100 Micron (DFT) Sea Quantum Pro-U Light Red - 01 Coat - 150 Micron (DFT) (Silyl Acrylate Anti-Fouling Self –Polishing Paint) Sea Quantum Pro-U- dark Red - 01 Coat - 150 Micron (DFT) (Silyl Acrylate Anti-Fouling Self –Polishing Paint) Under Water Portion Anti-Fouling Paint (Safe Guard Universal ES Grey, Pen Guard HB Primer, Sea Quantum Pro-U, Light Red, Sea Quantum Pro-U- Dark Red)To Be Required As Per International Maritime Organization (IMO) Scheme.

1

-

-

... More
All Above Water Painting as Vessel Requirement (It is suggested that FRP addition based Marine paint rquired to be utilized). Above water level complete cleaning surface finishing and lamination wherever required and painting as per vessel painting scheme

1

-

-

... More
All Vessel Outer Body Required Painting Vessel outer body cleaning and complete painting in disruptive pattern as per original painting scheme

1

-

-



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements

Past Bidders
This list is curated from the bidders of the similar tenders in the past

Unlock the Tender details for free
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.