Airports Authority Of India Tender
Search for the latest Gujarat tenders online related to civil works, road & transport, pipelines and more easily here on BidAssist. Here you can get any and every tender that is posted on the eProcurement Gujarat website, minus the clutter. No need for a tender ID, as on BidAssist, you can view any Gujarat tender by merely typing Gujarat in the search box.
Costs
EMD
₹ 48,336Document Cost
₹ 1,180Tender Fee
Refer Documents
Summary
Operation And Maintenance Contract For The E And
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2020_AAI_53557_2Bid Award Id
ViewTender No
AAI/KES/AGM(E-E)/eNIT-01/20-21Tender Authority
Airports Authority Of India ViewPurchaser Address
-Website
http://https://www.aai.aero/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
BOQ Items
1.5 Ton Split type (1-Ø,50Hz) (11 Nos.X 24 months + 4 Nos.x16 months) = 328 jobs.)
328
-
-
2 Ton Split type (1-Ø,50Hz) (2 Nos.X 24 months = 48 jobs.)
48
-
-
5 Ton Cassette type (3-Ø,50Hz) (5 nos. X 24 months = 120 jobs.)
120
-
-
Annual comprehensive maintenance contract including repair/replacement of all parts for Voltas/Usha make water Cooler at different locations in airport premises complete as per site requirement for following capacity & make (Each one Set/Job per month).
-
-
-
40/50/80 ltrs water Cooler (Usha make) (5Nos. x 24 months= 120 Jobs)
72
-
-
150/150 ltrs water Cooler (Blue Star make) (1 Nos. x 16 months= 16 Jobs)
16
-
-
Annual Comprehensive maintenance contract including consumable items and all spare parts i/c. membrane etc. of all makes of RO unit at different locations in airport premises complete as per site requirement for following type & capacity (Each Job per month)
-
-
-
25/40 LPH RO unit (5 Nos. x 24 months = 120 Job)
120
-
-
50 LPH RO unit ( 1 No. x 16 months = 1 JOB)
16
-
-
Dismantling, Shifting & Reinstallation of 1.5 / 2.0 /5.0 Ton Capacity of all makes & types of A/C unit in airport premises (Job i/c piping work upto 2 feet, Gas charging etc complete as required ).
4
-
-
Servicing, repairing, rewinding and replacement of defective part like bearings, bushing etc. and also transporting from site to contractors workshop & back to site, testing and commissioning etc. complete as per site requirement for the following motors ( Dismantle material belongs to Contractor)
-
-
-
Ceiling Fan/Wall Fan (1-Phase, 50Hz, 240V AC)
10
-
-
Exhaust fan Up to 450 mm (1-Phase, 50Hz,240V AC )
4
-
-
3 HP to 5 HP pump motor sets (3-Phase, 50Hz,415V AC )
2
-
-
Servicing, repairing and replacement of defective part like Relay, PCB etc. of Electronic voltage stabilizer for AC units including transportation from site to contractor's workshop & back to site. (Dismantle Material belongs to contractor).
4
-
-
Calibration of CCR & Sensitivity of relay on 4 KW to 20 KW CCR of NASU/AMA make CCR including submitting reports etc., complete as required.
9
-
-
Calibration of PAPI Clinometer etc. complete as required.
2
-
-
Inspection, servicing, setting, testing, adjustment, calibration and submission of calibration certificate of following instruments including minor repairs etc. Complete as per site requirement.
-
-
-
Electronic IDMT Relay
2
-
-
Voltmeter Digital suitable for AC supply.
14
-
-
Ammeter Digital suitable for AC supply.
14
-
-
Digital Power Factor (Cos Ø) Meter/frequency meter
16
-
-
Painting of light poles with aluminium paint of (2 coats) of approved brand and make, along with one coat of primer, including cleaning the surface all as required. Painting of each pole will be treated as one job.
57
-
-
Decoration of Terminal building facia with LED serial lighting and RGB pattern lighting on special occasions/nationally important days/festivals as per the requirements shown below -
(i) Minimum no. of LED serial lighting - not less than 5000 LED lights.
(ii) Pixel Chaser light batten running linearly on the top of the building, ATC tower, entry gate walls for a length of not more than 350 m. (iii) Halogen focus lights (Green or Yellow) for trees around terminal building - 10 Nos.
Type of Decoration will be as per the theme of occasions and upto the statisfaction of the Engineer In-charge/Airport Director.
-
-
-
Independence day /Republic day / AAI foundation day / Christmas / New Year (Starting from 18.00 hrs. on the Day before the Occasions to till 06.00 hrs on the day after the Occasions) Each occasion in an year shall be treated as one Job.
4
-
-
Execution of Complete items of CPWD Delhi schedule of rates (E&M) 2018.[Up to a Ceiling limit of Rs. 60,000 without GST]. The materials used for executing the DSR items shall be as per the approved make list of AAI, as enclosed with the tender document.
60000
-
-
Supply of HT insulation tape roll of size 19mmX 0.9mm of length not less then 9 Mtr
3
-
-
Supply of LT insulation tape roll of colour red,green,blue and black of length not less then 9 Mtr per roll
20
-
-
Supply of 3/9/12 W LED bulb suitable for operation on 230 V, 50Hz, AC AC supply complete etc as required. (Make: Havells, Code: LHLDEUHEML8R009 or Equivalent)
60
-
-
200 W 6.6 A bipin runway halogen lamp
50
-
-
Lamp holder for runway/taxiway halogen lamps
50
-
-
Clear lens suitable for AMA MK-III PAPI Unit (Make- AMA)
3
-
-
Red filter suitable for AMA MK-III PAPI Unit (Make- AMA)
3
-
-
Aluminium Reflector suitable for AMA MK-III PAPI Unit (Make- AMA)
6
-
-
Air Filter suitable for AMA MK-III PAPI Unit (Make- AMA)
6
-
-
Upper Breakable Coupling (Upper Breakable Point + Upper Leg Plate) suitable for AMA MK-III PAPI Unit (Make- AMA)
6
-
-
Lower breakable coupling for AMA make PAPI
6
-
-
Upper leg pipe (LH threaded) for AMA make PAPI
6
-
-
Lower Leg Pipe for AMA make PAPI
6
-
-
Locking Nut for upper pipe (RH threaded) for AMA make PAPI
6
-
-
Locking Nut for lower pipe(LH threaded) for AMA make PAPI
6
-
-
Threaded adjustment sleeves (Middle Nut) for AMA make PAPI
2
-
-
Supply of TDS meter
1
-
-
Digital Clamp Meter/ Tongtester suitable for DC/AC/TRMS (Make-Meco, Model-1080-TRMS)
1
-
-
Digital Insulation Tester with DC test voltage-500 V, 0-200 M ohms Range, and Resolution-0.1 M ohms (Make-Meco, Model-DIT 99C)
1
-
-
Supply of Earth Tester set
1
-
-
Supply of driver for existing LED signage board Suitable to operate inbuilt dual circuit having variable current 2.8 A to 6.6 Amp with auto changeover facility. The driver should be able to drive LED strips of 0.5 Watts Osram LED's assembled on aluminium PCB of size 700mm X 20mm and having 11 LED's per PCB for boards. from 5 strips to 20 strips.
5
-
-
Supply of LED strip with high luminous long life typically 50,000 hrs type, 0.5 watts Osram LED's assembled on aluminum PCB of size 700mm X 20mm X 2mm and having 11 LED's per PCB for boards. (make- Poshdecor)
At one end single non-reversible jack to be provided for easy replacement of LED without tools at site.
10
-
-
Supply of loop wire with non-reversible male jack of length 1 Mtr each for LED strips.
4
-
-
1000 W Halogen Lamp for High mast
5
-
-
Supply of 12 V, 180 Ah SMF lead acid batteries for DG Set
2
-
-
Supply of PAPI calibration stick holder/bracket with cover all as reqd. (as per sample)
2
-
-
Supply of halogen lamp holder suitable for AMA make PAPI unit complete with insulated leads etc. as reqd. (as per sample)
9
-
-
Supply of following Plug in type relays suitable for 20/4 KW CCR
-
-
-
24 VDC
2
-
-
48 VDC suitable for 11 pin socket
2
-
-
240 VAC
2
-
-
Supply of TI 300 Trip indication fuses for 20/4 KW CCR.
2
-
-
Supply of following High speed Semi-conductor Protection Fuses :
-
-
-
GS 1000/100 ( (Suitable for 20 KW CCR )
2
-
-
GSB 50 (Suitable for 4 KW)
2
-
-
Supply of following HRC Fuse Link :
-
-
-
100 Amps (2 Nos each for 20 KW CCR)
2
-
-
32 Amps (Suitable for 20 KW & 4 KW CCR)
2
-
-
Power Transistors MJ11016 suitable for all rating of CCRs.
2
-
-
Evaluation Notes How It Works ?