Sewage And Infrastructure Development Corporation Of Goa Limited Tender
Take tender evaluation notes for Goa SIDCGL Tender
Costs
EMD
₹ 17,19,425Document Cost
₹ 25,000Tender Fee
₹ 6,000
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2025_SIDCG_22032_1Bid Award Id
ViewTender No
SIDCL/Admn-7/F.No.TN-02/ 142/ 25-26 Dt 16/04/2025 Ln8Tender Authority
Sewage And Infrastructure Development Corporation Of Goa Limited ViewPurchaser Address
-Website
http://eprocure.goa.gov.in
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
BOQ Items
... More
a) 200 mm OD
1694
144
243936
... More
Conducting Sl.JE Survey in a corridor of 4-6 meter width to detect buried utilities like pipes, cables etc. in such corridor. Marking of the detected utilities on the map of corridor with information of locations and depths to the top of various utilities detected. Onsite detection to be conducted using minimum tools of Electronic Pipe Locator (EPL) and Ground Penetrating Radar (GPR). GPR work to be conducted using 500MHz and 300MHz antenna for best possible resolution and penetration. The specifications are SUE survey should be in accordance with 'Code of Practice for Subsurface Utility Engineering Suiting Indian Conditions - Guidelines & Specifications for Detection , Verification & Depiction of Existing Subsurface Utility Data'. Along the road, 6 m wide corridor
1694
69
116886
... More
Conducting sesmic refraction survey to determine statigraphy along proposed route i.e. soil wethered roack, roack interfaces. Detection of faults, fractures, shears zones etc., in the investigated area. Geophone spacing 5m, test to be conducted using 24 channel signal enhancement type seismograph. 5m Geophone spacing & for projects having minimum length of 115m
1694
371
628474
... More
Conducting Electrical Tomography to determine shallow stratigraphy along the route, presence of voids, saturation zones, water table & other geogical features having contrast in resistivity with surrounding soils. Electrode spacing 5 meters, minimum electrode spread of 60 electodes. 5m Electrode spacing & for projects having a minimum length of 300m
1694
258
437052
... More
Excavation of non-structural pits for pipe jacking/ramming purpose in soil inclusive of all shuttering, strutting, and shoring and maintaining the shaft during construction operation and backfilling the same after the completion of work.
-
-
-
... More
For Shafts of 7.5mX5m upto a depth of 5m in all type of soil
70
1725
120750
... More
For Shafts of 7.5mX5m upto a depth of 5m in all type of soil mixed with soft rock
160
5980
956800
... More
For Shafts of 7.5mX5m upto a depth of 5m in all type of soil mixed with hard rock
240
8050
1932000
... More
Confined Excavation of Shaft for pipe jacking/ramming purpose in soil inclusive of H Beam strutting with MS Plate/ Cubical wooden laggings and backfillings the same after the completion of work.
-
-
-
... More
For Shafts of 7.5mX5m upto a depth of 5m in all type of soil
24
2242
53808
... More
For Shafts of 7.5mX5m upto a depth of 5m in all type of soil mixed with soft rock
47
8050
378350
... More
Closed planking in trenches including strutting and shoring packing cavaties (wherever required) complete for sewerage works in saturated soil strata. for works of depth of upto 4.5 m
2250
1193
2684250
... More
Refilling the pipeline/foundation trenches plinth sides, foundation etc with available excavated earth in layers not exceeding 20 cm depth consolidating each layer ramming and watering lead upto 50 m and all lifts and disposal of surplus earth directed by Engineer-in-charge.
541
245
132545
... More
Installation of HEPE product pipe by HOD method for on grade gravity sewer including preparing and setting up the plant and equipment, preparing new pipe-work material, making of entry & exit pits upto 3 meter depth, installing new pipe-work and commissioning system or making the system ready for commissioning by HOD operating including, all related civil and mechanical works like excavation, shoring/ strutting, etc. drilling, stringing, reaming, and pulling back the new pipe-work on the designed bore path alignment, proper disposal of drilling fluid and back fill of site after completion all inclusive as per lndSTT:101-2018: Code of Practice for Horizontal Directional Drilling Technique Suiting Indian Conditions. Other Types Soil / Mixed Strata
-
-
-
... More
a) 200 mm OD - Soft Soil
339
3393
1150227
... More
b) 200 mm OD - Mixed Strata
339
8395
2845905
... More
c) 200 mm OD - Rocks
1016
25242
25645872
... More
Cutting the bituminous road for laying the pipeline in trenches for a width of 0.6m including labour, tools etc, and disposing the excavated excess material from the trench to a distance of 1000 meters, including making level the trench surface by utilsing the serviciable material to the level of the top surface of road, by compacting, watering ramming with rolling with road roller after completion of laying of pipe and refilling the trenches etc. complete as per the direction of engineer incharge. Mechanical Means.
160
506
80960
... More
Construction of Composite type Manholes of various diameters and depth , as per the detailed specification of items of work annexed
-
-
-
... More
i) 1200mm dia x upto 2000mm depth
37
266175
9848475
... More
ii) 1200mm dia x 2000 to 2300mm depth
11
306616
3372776
... More
iii) 1500mm dia x 2300 to 2500mm depth
3
398332
1194996
... More
iv) 1500mm dia x 2500 to 3000mm depth
5
488062
2440310
... More
v) 1500mm dia x 3000 to 3500mm depth
5
552086
2760430
... More
vi) 1500mm dia x 3500 to 4000mm depth
1
622681
622681
... More
vii) 1500mm dia x 4000 to 4500mm depth
2
712698
1425396
... More
viii) 1500mm dia x 4500 to 5000mm depth
3
777887
2333661
... More
ix) 1500mm dia x 5000 to 5500mm depth
2
894974
1789948
... More
xi) 1500mm dia x 6000 to 6500mm depth
1
1064032
1064032
... More
Providing 2mm thick M.S clamp welded with ISA 50x50x6mm at ends including appliation of bonding solution such as SR solvent of fevicol or Dr fixit or any other equivalent product including fixing with necessary nut, bolt and applying a coat of red oxide etc. Complete as per directed by Engineer -in-charge.
-
-
-
... More
a) 200 mm
145
1191
172695
... More
Providing and laying in position cement concrete below foundation M15(1:2:4) (1 cement : 2 coarse sand: 4 graded granitic or basaltic stone aggregate 40 m nominal size) excluding cost of centering, shuttering and finishing : For Concrete Blocks
179.625
6810
1223246.25
... More
Supplying of laterite stone soling of size 150-200 mm and murum having P.I value not more than 6 and laying including packing with smaller stones and consolidation with power road roller including spreading, watering & consolidation of binding material etc (measurements shall be considered on finished item)
526
1867
982042
... More
Providing and laying 50mm(consolidated thickness) full grout using granitic or basaltic stone of specified grading at 6.00 cu.m. per 100 sq.m. grouting with hot bitumen straight run bitumen(or with such bituminous material of grade and type as specified by the Engineer-in-Charge)at 5.0kg. per sq. m. binding with key aggregate of granitic or basaltic stone of specified grading at 1.5 cu.m. per 100 sq.m. including Providing and laying seal coat sealing the voids in a bituminious surface laid with F.E loader with 1 Cu.m. bucket capacity to the specified levels, grade and cross fall using Type A seal coat with 0.98 kg/sqm of bitumen of grade as per MoRT&H specifications clause 513.
1760
631
1110560
... More
Providing and applying tack coat with bitumen grade of 80/100 or bitumen emulsion using pressure distributor on the prepared bituminous/granular surface cleaned with mechanical broom as per MoRT&H specifications clause 503. Bitumen 80/100 @ 0.20 kg/sq.m
1760
17
29920
... More
Bituminous Macadam (Providing and laying bituminous macadam with 100-120 TPH hot mix plant producing an average output of 75 tonnes per hour using crushed aggregates of specified grading premixed with bituminous binder, transported to site, laid over a previously prepared surface with paver finisher to the required grade, level and alignment and rolled as per MORT& H Specifications,Fifth Edition. for GradingII(19 mm nominal size)
88
9741
857208
... More
Providing and laying in position cement concrete below foundation M15(1:2:4) (1 cement : 2 coarse sand: 4 graded granitic or basaltic stone aggregate 40 m nominal size) excluding cost of centering, shuttering and finishing : For Repairing Damaged Drains
135
6810
919350
... More
Centering & shuttering including Strutting, Propping & removal of forms for vertical Surfaces Such as Walls
539
479
258181
... More
Providing,Laying and jointing of unplasticised non-pressure PVC pipes for using underground drainage and sewerage system confirming to IS : 15328 - 2003 stifness class SN-8 (8 KN/m2,SDR -34) including Earthwork in excavation by manual means in foundation pipeline trenches drain (not exceeding 1.5m in width or 10 sq. m. on plan) in all types of soil including dressing of sides and ramming of bottoms, lift upto 1.5 m including getting out the excavated soil and disposal of surplus excavated soil as directed within a lead of 5km and Refilling the pipeline trenches with plum cement concrete 1:3:6 and disposal of surplus earth as directed by the Engineer in charge including excavation, cutting and reinstating of road rural road and storm water drain, encasing with PCC 1:2:4 as per IS:4127, rubble packing and refilling after completion of work in different areas of Succorro in Porvorim Constituency a)160mm OD
1072
6523
6992656
... More
Providing,Laying and jointing of unplasticised non-pressure PVC pipes for using underground drainage and sewerage system confirming to IS : 15328 - 2003 stifness class SN-8 (8 KN/m2,SDR -34) including Earthwork in excavation by manual means in foundation pipeline trenches drain (not exceeding 1.5m in width or 10 sq. m. on plan) in all types of soil including dressing of sides and ramming of bottoms, lift upto 1.5 m including getting out the excavated soil and disposal of surplus excavated soil as directed within a lead of 5km including Bed concrete 1:2:4(1 cement:2 coarse sand:4 graded granitic a basaltic stone aggregate 20mm nominal size) including rubble packing and Refilling the pipeline trenches with available excavated earth in layers not exceeding 20cm depth consolidating each layer ramming and watering lead upto 5km and all lifts and disposal of surplus earth as directed by the Engineer in charge. a)160mm OD
544
2167
1178848
... More
Construction of manhole rectangular in shape including cement concrete 1:3:6 (1 cement:3 coarse sand:6 graded stone aggregate 20mm nominal size) foundation thickness of concrete 20cms and offset 10cms on both sides and first class brick work with bricks class designation 100kg/cm2 in cement mortar 1:3 (1 cement : 3 coarse sand) 23cms thick including providing & fixing CI footrests confirming to IS 5445/69 or revised and whose weight shall not be less than 5.30kgs including fixing in man-hole at 30cm c / c in 20x 20x15cm cement concrete block 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20mm nominal size) and 12mm thick plaster inside and outside with cement mortar 1:3 (1 cement : 3 coarse sand) including adding waterproofing compound of approved brand in cement mortar with a floating coat of neat cement and making channel in cement concrete 1:2:4 (1 cement :2 coarse sand : 4 graded stone aggregate 20m nominal size) neatly finished complete as per standard design including Earthwork in excavation by manual means in foundation pipeline trenches drain (not exceeding 1.5m in width or 10 sq. m. on plan) including dressing of sides and ramming of bottoms, lift upto 1.5 m including getting out the excavated soil and disposal of surplus excavated soil as directed within a lead of 5km. and Refilling the pipeline trenches with available excavated earth in layers not exceeding 20cm depth consolidating each layer ramming and watering lead upto 5km and all lifts and disposal of surplus earth as directed by the Engineer in charge. Inside size 0.90 x 0.60m and 1.00m deep (with precast RCC slab covers of concrete grade M25 30T capacity of size 0.90x 0.60m fixing with cement concrete 1:2:4 ( 1 cement : 2 coarse sand : 4 graded stone aggregate 20mm nominal size and applying the frame & cover with coal tar.) including Supplying & fixing of S.W. intercepting trap of 6" dia inside the inspection chamber with Making connection of drain or sewer line with existing manhole including breaking and making good the walls, floors with cement concrete 1:2:4 (1 cement: 2 coarse sand: 4 graded stone aggregate 20mm nominal size) 12mm thick cement plaster on both sides with cement mortar 1:3 (1 cement:3 coarse sand) finished with a floating coat of neat cement and making necessary channels for drains etc. for connecting to HSC manhole including rubble packing etc. complete.all lifts and disposal of surplus earth as directed by the Engineer in charge. Inside size 0.90 x 0.60m and 1.00m deep (with precast RCC slab covers of concrete grade M25 12T capacity & frame of size 0.90x0.60 including fixing with cement concrete 1:2:4 ( 1 cement : 2 coarse sand : 4 graded stone aggregate 20mm nominal size and applying the frame & cover with coal tar.) including Supplying & fixing of S.W. intercepting trap of 6" dia inside the inspection chamber with Making connection of drain or sewer line with existing manhole including breaking and making good the walls, floors with cement concrete 1:2:4 (1 cement: 2 coarse sand: 4 graded stone aggregate 20mm nominal size) 12mm thick cement plaster on both sides with cement mortar 1:3 (1 cement:3 coarse sand) finished with a floating coat of neat cement and making necessary channels for drains etc. for connecting to HSC manhole including rubble packing etc. complete.
81
27413
2220453
... More
Construction of manhole rectangular in shape including cement concrete 1:3:6 (1 cement:3 coarse sand:6 graded stone aggregate 20mm nominal size) foundation thickness of concrete 20cms and offset 10cms on both sides and first class brick work with bricks class designation 100kg/cm2 in cement mortar 1:3 (1 cement : 3 coarse sand) 23cms thick including providing & fixing CI footrests confirming to IS 5445/69 or revised and whose weight shall not be less than 5.30kgs including fixing in man-hole at 30cm c / c in 20x 20x10cm cement concrete block 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20mm nominal size) and 12mm thick plaster inside and outside with cement mortar 1:3 (1 cement : 3 coarse sand) including adding waterproofing compound of approved brand in cement mortar with a floating coat of neat cement and making channel in cement concrete 1:2:4 (1 cement :2 coarse sand : 4 graded stone aggregate 20m nominal size) neatly finished complete as per standard design. Inside size 0.60x0.60m and 0.60m deep (with precast RCC slab covers of concrete grade M25 12T capacity & frame of size 0.60x 0.60m) including fixing with cement concrete 1:2:4 ( 1 cement :2 coarse sand : 4 graded stone aggregate 20mm nominal size and applying the frame & cover with coal tar.including Earthwork in excavation by manual means in foundation pipeline trenches drain (not exceeding 1.5m in width or 10 sq. m. on plan) including dressing of sides and ramming of bottoms, lift upto 1.5 m including getting out the excavated soil and disposal of surplus excavated soil as directed within a lead of 5km. and Refilling the pipeline trenches with available excavated earth in layers not exceeding 20cm depth consolidating each layer ramming and watering lead upto 5km and all lifts and disposal of surplus earth as directed by the Engineer in charge including rubble packing etc complete.
64
14119
903616
... More
Extra/Additional depth of above square/ rectangular manholes at above item no in fractions with 100kg/cm2 brickwork in cement morter 1:3 (1cement:3coarse sand) 23cm thick including providing and fixing CI footrests not weighing less than 5.30kgs incl. fixing in manholes @ 30cmc/c staggered in 20x20x10cm cement concrete blocks 1:3:6(1cement:3coarse sand :6graded stone aggregate 20mm nominal size) 12mm thick plaster inside and outside with cement morter 1:3 (1cement :3coarse sand)including adding water proofing compound of approved brand with a floating coat of neat cement for 0.60 x 0.60m Manholes. including Earthwork in excavation by manual means in foundation pipeline trenches drain (not exceeding 1.5m in width or 10 sq. m. on plan) including dressing of sides and ramming of bottoms, lift upto 1.5 m including getting out the excavated soil and disposal of surplus excavated soil as directed within a lead of 5km.and Refilling the pipeline trenches with available excavated earth in layers not exceeding 20cm depth consolidating each layer ramming and watering lead upto 5kM and all lifts and disposal of surplus earth as directed by the Engineer in charge. cement morter 1:3 (1cement :3coarse sand) including adding water proofing compound of approved brand with a floating coat of neat cement for 0.60 x 0.60m Manholes. including Earthwork in excavation by manual means in foundation pipeline trenches drain (not exceeding 1.5m in width or 10 sq. m. on plan) including dressing of sides and ramming of bottoms, lift upto 1.5 m including getting out the excavated soil and disposal of surplus excavated soil as directed within a lead of 5km.and Refilling the pipeline trenches with available excavated earth in layers not exceeding 20cm depth consolidating each layer ramming and watering lead upto 5kM and all lifts and disposal of surplus earth as directed by the Engineer in charge. . .
1990
166
330340
... More
Dismantling of Chequered tiles flooring including PCC bed and reinstating with Chequered tile Flooring Wherever required in side apartment premises and house premises as required for providing House sewer connections including rubble packing , cement concrete 1:2:4 & disposal of surplus material to lead upto 5km
210
2405
505050
... More
Construction of manhole rectangular in shape including cement concrete 1:3:6 (1 cement:3 coarse sand:6 graded stone aggregate 20mm nominal size) foundation thickness of concrete 20cms and offset 10cms on both sides and first class brick work with bricks class designation 100kg/cm2 in cement mortar 1:3 (1 cement : 3 coarse sand) 23cms thick including providing & fixing CI footrests confirming to IS 5445/69 or revised and whose weight shall not be less than 5.30kgs including fixing in man-hole at 30cm c / c in 20x 20x15cm cement concrete block 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20mm nominal size) and 12mm thick plaster inside and outside with cement mortar 1:3 (1 cement : 3 coarse sand) including adding waterproofing compound of approved brand in cement mortar with a floating coat of neat cement and making channel in cement concrete 1:2:4 (1 cement :2 coarse sand : 4 graded stone aggregate 20m nominal size) neatly finished complete as per standard design including Earthwork in excavation by manual means in foundation pipeline trenches drain (not exceeding 1.5m n width or 10 sq. m. on plan) including dressing of sides and ramming of bottoms, lift upto 1.5 m including getting out the excavated soil and disposal of surplus excavated soil as directed within a lead of 5km. and Refilling the pipeline trenches with available excavated earth in layers not exceeding 20cm depth consolidating each layer ramming and watering lead upto 5km and all lifts and disposal of surplus earth as directed by the Engineer in charge. Inside size 0.90 x 0.60m and 1.00m deep (with precast RCC slab covers of concrete grade M25 30T capacity of size 0.90x 0.60m fixing with cement concrete 1:2:4 ( 1 cement : 2 coarse sand : 4 graded stone aggregate 20mm nominal size and applying the frame & cover with coal tar.) including Supplying & fixing of S.W. intercepting trap of 6" dia inside the inspection chamber with Making connection of drain or sewer line with existing manhole including breaking and making good the walls, floors with cement concrete 1:2:4 (1 cement: 2 coarse sand: 4 graded stone aggregate 20mm nominal size) 12mm thick cement plaster on both sides with cement mortar 1:3 (1 cement:3 coarse sand) finished with a floating coat of neat cement and making necessary channels for drains etc. for connecting to HSC manhole including rubble packing etc. complete.all lifts and disposal of surplus earth as directed by the Engineer in charge. Inside size 0.90 x 0.60m and 1.00m deep (with precast RCC slab covers of concrete grade M25 12T capacity & frame of size 0.90x0.60 including fixing with cement concrete 1:2:4 ( 1 cement : 2 coarse sand : 4 graded stone aggregate 20mm nominal size and applying the frame & cover with coal tar.) including supply and fixing of Supplying & fixing of Oil & Grease trap of 24x12x12 inside the inspection chamber with Making connection of drain or sewer line with existing manhole including breaking and making good the walls, floors with cement concrete 1:2:4 (1 cement: 2 coarse sand: 4 graded stone aggregate 20mm nominal size) 12mm thick cement plaster on both sides with cement mortar 1:3 (1 cement:3 coarse sand) finished with a floating coat of neat cement and making necessary channels for drains etc. for connecting to Hotels, Bar and restaurants, Garage etc manhole including rubble packing etc. complete.
1
97352
97352
... More
Add extra for conical brick masonry manhole for fractional depth of each one centimeter or part thereof for b)1.20m dia. .including Earthwork in excavation by manual means in foundation pipeline trenches drain (not exceeding 1.5m in width or 10 sq. m. on plan) including dressing of sides and ramming of bottoms, lift upto 1.5 m including getting out the excavated soil and disposal of surplus excavated soil as directed within a lead of 5km.and Refilling the pipeline trenches with available excavated earth in layers not exceeding 20cm depth consolidating each layer ramming and watering lead upto 5km and all lifts and disposal of surplus earth as directed by the Engineer in charge
25
331
8275
... More
Demolishing cement concrete 1:3:6 or richer mix including disposal of material within 50m lead.
39.03
1122
43791.66
... More
Rubble packing with hard laterite stone under floors including watering ramming and consolidating etc. in pipeline trenches and other foundations complete.
24.52
2211
54213.72
... More
Centering and shuttering including strutting, propping etc. and removal of formwork for: a) Foundations footings, bases for columns and mass concrete.
52.8
407
21489.6
... More
Providing and laying cement concrete 1:2:4(1 cement:2 coarse sand:4 graded granitic a basaltic stone aggregate 20mm nominal size) excluding cost of centering, shuttering and finishing in All Works upto Plinth Level
39.03
6810
265794.3
... More
As per Circular No.3-3-05/SSW-PWD/Vol-I/2022-23/391 Dt.13/03/2023 for Adoption of percentage increase in rates for working under unhygenic conditions
1
1262187
1262187.93
Evaluation Notes How It Works ?
Potential Partner
Select Your Requirements