Public Works Department Tender

View complete overview of Goa PWD Tender

Public Works Department - PWD Tender

Works
Civil And Construction
Road Construction
Eprocure
Opening Date14 Oct 2022
Closing Date20 Oct 2022
Tender Amount₹ 1,67,39,036 
Notes
Download

Costs

  • EMD

    ₹ 3,34,781
  • Document Cost

    ₹ 8,000
  • Tender Fee

    ₹ 6,000

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
Plain/Reinforced cement concrete in sub-structure complete as per drawing and technical specifications (B) PCC Grade M20 (p) Height upto 5m

546

-

6472

... More
Supplying and fixing Pre-cast cement concrete kerb-stones(factory made,the factory should be ISO certified and registered under Dirctorate of Industries, Govt. of India) of M-20 with 20 mm nominal size granitic/basaltic aggregate properly consolidated by mechanical plat-form and vibrators with smooth finish including fixing at site complete as per specification. (A) Size 30 cm L x 50 cm H x 15 cm T

200

-

663

... More
(Loosening of the ground upto a level of 500 mm below the subgrade level, watered, graded and compacted in layers to meet requirement of table 300-2 for subgrade construction.) Case-II Compacting original ground supporting embankment

2520

-

28

... More
Construction of embankment with approved material obtained from borrow pits with all lifts and leads, transporting to site, spreading, grading to required slope and compacting to meet requirement of table 300-2.

3024

-

613

... More
Construction of sub-grade and earthen shoulders with approved material obtained from borrow pits with all lifts & leads, transporting to site, spreading, grading to required slope and compacted to meet requirement of table No. 300-2

1260

-

630

... More
Construction of granular sub-base by providing coarse graded Material, spreading in uniform layers with motor grader on prepared surface, mixing by mix in Plant method at OMC, and compacting with vibratory roller to achieve the desired density, complete as per clause 401 ii) for grading- II Material

378

-

2312

... More
Providing, laying, spreading and compacting graded stone aggregate to Wet Mix Macadam specification including premixing the Material with water at OMC in mechanical mix plant carriage of mixed Material by tipper to site, laying in uniform layers with paver in sub- base / base course on well prepared surface and compacting with vibratory roller to achieve the desired density.

378

-

3230

... More
Providing and applying primer coat with bitumen emulsion on prepared surface of granular Base including clearing of road surface and spraying primer at the rate of 0.60kg/sqm using mechanical means.

2520

-

28

... More
Dense Graded Bituminous Macadam (Providing and laying dense bituminous macadam with 100-120 TPH batch type HMP producing an average output of 75 tonnes per hour using crushed aggregates of specified grading, premixed with bituminous binder @ 4.0 to 4.5% by weight of total mix of mix and filler, transporting the hot mix to work site, laying with a hydrostatic paver finisher with sensor control to the required grade, level and alignment, rolling with smooth wheeled, vibratory and tandem rollers to achieve the desired compaction as per MoRTH specification clause No. 505 complete in all respects.) ii) for Grading II(19 mm nominal size)

189

-

11131

... More
Providing and applying tack coat with bitumen emulsion using emulsion pressure distributor at the rate of 0.2kg per sqm on the prepared bituminous/granular surface cleaned with mechanical broom.

2520

-

11

... More
Providing and laying bituminious concrete with 40-60 TPH Drum Mix type Hhot mix plant producing an average output of 50 tonnes per hour using crushed aggregates of specified grading, premixed with bituminious binder to mix with filler, transporting the hotmix to work site, with all leads laying with a Mechanical paver finisher to the required grade, level and alignment, using antistripping agent rolling with smooth wheeled, vibratory or tandem rollers to achieve the desired compaction complete as per MoRT&H Specifications Clause 509 Grade-II (13mm nominal size) @ 6.5% Bitumen of grade 60/70 a) Antistripping agent @ 0.5% of bitumen content

101

-

14515

... More
Type - B, Providing and erecting a "Thrie" metal beam crash barrier \providing and erecting "Thrie Beam " Crash barrier comprising of following three factory made unites- viz. 1) Thrie Beam 2) Spacer Block 3) Vertical Post. The Thrie beam 3mm thick cold roll formed guard rail raw material Conforming to IS-5986-2011 with minimum Grade 255 & with minimum yield stress of 255 Mpa which is fixed by bolted connection to spacer block C-channel of size 150mm* 75mm & 5mm thick, 54.6cm height spaced 2meter centre to centre, fixed to Vertical Post C-channel of size 150mm*75mm&5mm thick cold roll formed section made from HR coils raw material conforming to IS-5986- 2011 with minimum Grade 255 & with minimum yield stress of 255MPa, with 85cms free height above road or Ground level, and embedded to 115cms deep in cement concrete block of size 35cm*35*115cm or as directed by Engineer Incharge, assembled & fixed as per drawings of MORTH&H Circular No.RW/NH/33022/1/94-DO/III, dated 24/6/1994 & construction operation as per 811 or revevant MORT&H specifications for Roads & Bridge Works (latest edition). All fittings (bolts, nuts, fasteners, washers etc.) shall be conforming to IS:1367 & IS:1364 & galvanished by hot dip zinc coated process @0.55kg/m2 conforming to relevent IS specifications all etc. complete

360

-

4377

... More
Providing weep holes in Brick masonry/Plain/Reinforced concrete abutment, wing wall/return wall with 100 mm dia AC pipe, extending through the full width of the structure with slope of 1V :20H towards drawing foce. Complete as per drawing and Technical specifications

160

-

281

... More
Providing & fixing of cautionary sign board of Cautionary/Mandatory/Facility Information sign board made out of retro reflective sheeting conforming to Type XI standards of ASTM D4956-09 & as per IRC-67: 2012 specifications, fully covered over 4mm thick ACP/2mm thick Al supported with back support frame of 25x25x3 mm stainless steel angle of 304 grade. Board Shall be fixed to a vertical post of 80mm dia stainless steel pipe of 3.6 mtr height and firmly fixed to the ground by means of properly designed foundation with M20 grade cement concrete 45 cm X 45 cm X 60 cm etc, 60 cm below ground level. 10 years warranty & a certified copy of three years outdoor exposure report from an independent lab as per IRC 67-2012 for Type XI retro reflective sheeting shall be submitted by the contractor. b) 600 mm Triangle - Cautionary Sign

16

-

9039

... More
e) 600mm x 800mm Rectangle - Facility Information Sign

16

-

11496

... More
Increase in 20% on (Non corrigendum item)

1

-

2194877



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.