Public Works Department Tender
View complete overview of Goa PWD Tender
Costs
EMD
₹ 9,237Document Cost
₹ 4,000Tender Fee
₹ 1,000
Summary
Renovation/repairs To The Office Premises Allotted To The Dy.director (admin), Replacing Of 2 Nos Of Damaged Water Pump And Re-painting To The Office Of Sp Anc At Phq Complex,panaji.
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2025_PWD_19189_1Tender No
PWD/WDI/ASW-17/2024-2025/36/02Tender Authority
Public Works Department ViewPurchaser Address
-Website
http://eprocure.goa.gov.in
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
Renovation/Repairs to the office premises allotted to the Dy.Director (Admin), Replacing of 2 nos of damaged water pump and Re-painting to the office of SP ANC at PHQ Complex,Panaji.
BOQ Items
... More
Providing woodwork in frames of doors, windows, clerestory windows trusses & other frames wrought framed and fixed in positon.
B)Second class Indian teak wood
0.08
167470
13397.6
... More
Providing and fixing 35 mm thick panelled glazed or panelled and glazed shutters for doors, windows and clerestory window including anodized aluminium butt hinges with necessary screws:
b)Second class Indian teak wood
5.25
6662
34975.5
... More
Repairs to plaster in patches of 2.5 sq.m. and under including cutting the patch in proper shape and preparing and plastering the surface of the walls complete including disposal of rubbish to the dumping ground within 50m lead.
With cement mortar 1:4 (1 cement : 4 fine sand)
10.25
314
3218.5
... More
Removing old loose bottom or side cover of RCC slab, beam, columns etc. rubbing surface of concrete steel using wire brush and applying 2 coats of Alkaline rust converting primer (Feovert) after a waiting time of 6 hrs between coats and then applying another anti corrosive protective coating system ) for reinforcement bars (IPNet-RB) Conforms to IS-2770 Part-1 (Pull out Test) ASTM-3963-86 (Adhesion Test) and then applying concrete penetrating corrosion inhibitor (EPCO-KP100) and applying bonding new to old concrete (Epibond) Conforms to ASTM-C-882-87 and plastering on the fresh bond coat with Polymer Modified Mortar (Monobond) with 20mm C.M 1:3 and finishing coat of 6mm C.P 1:3 (1 Cement : 3 Sand ) incl. cost of transport etc. as per dir of EIC. All the chemicals will be of Krishna Conchem Products Pvt. Ltd. or Equivalent.
9.3
2086
19399.8
... More
Providing kirloskar centrifugal 2HP Pumb
2
18326
36652
... More
Removing dry or oil bound distemper by scrapping sand papering and preparing the surface smooth including necessary repairs to scratches etc. complete.
390.15
22
8583.3
... More
Providing and applying white cement based putty of average thickness 1.00mm of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete.
19.55
89
1739.95
... More
Distempering two or more coats with oil bound washable distemper of approved brand and manufacture and of required shade on new work over and including a priming coat with distemper primer of approved brand and manufacture to give an even shade.
390.15
124
48378.6
... More
Providing and fixing ASTM UPVC pipe, conforming to ASTM 2467 with ISO 14001, including all UPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step UPVC solvent cement and testing of joints complete as per direction of Engineer. Internal work - Exposed on wall. I) SCH-40(blue)/(white) a )20mm outer dia.
30
278
8340
... More
Providing and fixing ASTM UPVC pipe, conforming to ASTM 2467 with ISO 14001, including all UPVC plain & brass threaded fittings, including jointing of pipes & fittings with one step UPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer. External work. I) SCH-40(blue)/(white) a ) 20mm outer dia.
60
248
14880
... More
Earthwork in excavation by mechanical means (hydraulic excavator)/manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sq.m on plan) including disposal of excavated earth lead upto 50 m and lift upto 1.5m disposed earth to be leveled and neatly dressed including providing barricading, danger lighting guarding as directed in :
a)All kinds of soil
17.5
286
5005
... More
Dismantling of existing G.I pipe including disposal of unserviceable material and stacking of serviceable materials .
A) Upto 20 mm nominal bore
60
10
600
... More
Plumber, Electrician
a) Highly skilled
2.5
557
1392.5
... More
Steel work in built up tubular (round, square or rectangular hollow tubes etc.) (Square Hollow Section (SHS) IS4923 /Rectangular Hollow Section (RHS) IS4923/ Circular Hollow Section (CHS) IS1161 closed Structural Steel of (SAIL, TATA. VIZAG, JSW ,APOLLO Steel Ltd.) make (Min Yeild Stress 310 Mpa)) trusses etc., including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete.
263.58
184
48498.72
... More
Steel work welded (SAIL, TATA. VIZAG & using electrodes of Ador or ES4B or Deh Secheron make only)in built up sections trusses and framed work including cutting, hoisting, fixing in position and applying priming coat of red lead paint.
a) In R.S. Joists
0.9
13658
12292.2
... More
Painting two or more coats (excluding priming coat) with superior quality ready mixed paint for steel work of approved brand & manufacture in all shades on new work to give an even shade.
15.54
107
1662.78
... More
Providing and anchoring of anchor rod HI T-V-5.8M16X150 with injectable mortal HIT-RE 500 V4/500
32
679
21730.88
... More
Providing and fixing 20mm thick wooden planks ceiling (frame work for base to be paid separately) with M.S. screws
b)Nano or chafo wood
18
1409
25362
... More
Applying priming coat with ready mixed primer of approved brand and manufacture on wood work complete.
36
58
2088
... More
Painting one or more coats with superior quality ready mixed paint of wood work of approved brand & manufacture in all shades on old work to give an even shade.
37.38
72
2691.36
... More
chairs foa staff with medium back rest caster and arms.
2
7624
15249
... More
Providing of table type T-3 (Type C ) of size 1.20m x0.60m x0.75m table made of 19 mm thick marine plywood with desk top and 6mm thick glass top and vertical sides finished in 1mm laminate having 6mm thick half round teak wood moulding of one open space for CPU of width 0.30m and one sliding frawer above of 60mm depth of 12mm thick marine ply and one open shutter below drawer of width 0.45m face finished in 1mm laminate finish with foot rest.including necessary hardware such as SS hinges telescopic drawer channel 3" dia wire manager and all external 1mm laminate finish and inside laminate complete.
1
56545
56545
... More
TWO TRACK SLIDING WINDOW (Economical):-
Providing & fixing Two Track sliding window in economical section made out of 60mm x 45mm x 2.5mm Upvc multi cavity track section & Shutter made out of 57mm x 31mm x2.5mm Upvc multi cavity section welded in corners with Glass beading & EPDM Gasket & 4mm clear glass with lock & rollers. The average weight of Two Track Sliding window (Economical) is 12.25 kg per sq mtr. These Upvc sections are tested by using BS 2782 & DIN 53459 test methods.
4.5
6160
27720
... More
Providing and fixing curtain rods of 1.25 mm thick anodized aluminium plates brackets in pelment instead of wooden curtain rods of 25 mm diameter and brackets (actual length of rods to be measured).
A) 12 mm dia.
6
470
2820
... More
Supply of labour
4
621
2486
... More
TRANSPORTATION AND CARRIAGE OF MATERIALS
(A) By tipper truck including loading, unloading and stacking
(A) Lime,building rubbish, manure sludge, moorum excavated rock VII)15kms
3
436
1308.93
Evaluation Notes How It Works ?
Potential Partner
Select Your Requirements
Past BiddersThis list is curated from the bidders of the similar tenders in the past
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%