Public Works Department Tender
View complete overview of Goa PWD Tender
Costs
EMD
₹ 18,806Document Cost
₹ 5,000Tender Fee
₹ 1,881
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2024_PWD_18844_1Tender No
PWD IX /2062/13/2024-25 line03Tender Authority
Public Works Department ViewPurchaser Address
-Website
http://eprocure.goa.gov.in
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
BOQ Items
... More
Repairs , Servicing & Overhauling of 3.3KV, 400A load break Switch make A-Bond-Strands Pvt. Ltd by experienced technician as detailed below : a) Cleaning and checking of all parts. b) Greasing by using Molykote grease at required places and checking of spring operating mechanism for its perfect working condition. c) Checking of ON/OFF operation of breaker. d) Rectifying and adjusting free movement of breaker and testing .
3
35552
106656
... More
Supply and Replacement of Spares for 33KV, 1250A Type VY30M25D outdoor Vacuum citcuit breaker & 3.3KV, 630A Jyoti make , Type: VK10J25 , C -9386 , Vacuum Circuit Breaker .
i) Spur gear assembly ( 4VC49-0018) of approved make.
4
19690
78763.84
... More
Supply and Replacement of Spares for 33KV, 1250A Type VY30M25D outdoor Vacuum citcuit breaker & 3.3KV, 630A Jyoti make , Type: VK10J25 , C -9386 , Vacuum Circuit Breaker .
ii) Pinion gear assembly ( 4VC49-0091) of approved make.
4
15353
61412.04
... More
Supply and Replacement of spares for 3.3KV, 400A Jyoti mak Type: JVE-604 Vacuum Contactor.
i) Closing coil for Vacuum contactor 110V DC , (CC1 & CC2) , make Jyoti.
1
36198
36198.4
... More
Supply and Replacement of spares for 3.3KV, 400A Jyoti mak Type: JVE-604 Vacuum Contactor.
ii) 3.3KV HRC Fuse , 250A, make GE / Power (GEC)/ S&S.
1
35425
35425.75
... More
Servicing , testing and calibrating of protective relays on 33KV/3.3KV control panels, including repairs, replacing of contacts if any , confirmation of healthiness of tripping/ alarm circuit:
i) Tripping and auxiliary Relay
a) Relay type: VAA33 Auxiliary
8
2828
22624
... More
Servicing , testing and calibrating of protective relays on 33KV/3.3KV control panels, including repairs, replacing of contacts if any , confirmation of healthiness of tripping/ alarm circuit:
i) Tripping and auxiliary Relay
b) Relay type: VAA23 Auxiliary
2
2828
5656
... More
Servicing , testing and calibrating of protective relays on 33KV/3.3KV control panels, including repairs, replacing of contacts if any , confirmation of healthiness of tripping/ alarm circuit:
i) Tripping and auxiliary Relay
c) Relay type: VAJH13 Tripping
7
2828
19796
... More
Servicing , testing and calibrating of protective relays on 33KV/3.3KV control panels, including repairs, replacing of contacts if any , confirmation of healthiness of tripping/ alarm circuit:
i) Tripping and auxiliary Relay
d) Relay type: CDG31 IDMT ( 2 O/C + 1 Earth Fault )
2
5757
11514
... More
Servicing , testing and calibrating of protective relays on 33KV/3.3KV control panels, including repairs, replacing of contacts if any , confirmation of healthiness of tripping/ alarm circuit:
i) Tripping and auxiliary Relay
e) Relay type: CDG61 (2 O/C + 1 Earth fault + High set for each Element )
2
6060
12120
... More
Servicing , testing and calibrating of protective relays on 33KV/3.3KV control panels, including repairs, replacing of contacts if any , confirmation of healthiness of tripping/ alarm circuit:
i) Tripping and auxiliary Relay
f) Relay type: VDG13 Under voltage
2
2929
5858
... More
Servicing , testing and calibrating of protective relays on 33KV/3.3KV control panels, including repairs, replacing of contacts if any , confirmation of healthiness of tripping/ alarm circuit:
i) Tripping and auxiliary Relay
g) Relay type: MRM3-E5-DM Motor Protection Relay
3
5252
15756
... More
Primary injection test on 3.3 KV Current Transformers of incomers (CT ratio : 400/5/5Amps )& motor feeders ( CT ratio: 125/5/5Amps ) for confirmation of healthiness.
18
4090
73629
... More
Primary injection test on 3.3KV/ √3/ 110V/ √3 PT’s provided in incomers of control and relay panel for confirmation of healthiness.
6
4090
24543
... More
Supply and replacement of damaged/burnt striker fitted HT fuses3.3KV, 50Amps of Make: Eswari (Anand), Type: NGT complete as required.
3
40703
122109
Evaluation Notes How It Works ?
Potential Partner
Select Your Requirements
Past BiddersThis list is curated from the bidders of the similar tenders in the past
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%