Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2025_PWD_20683_1Bid Award Id
ViewTender No
PWD/DIVISION XVI (BC)/TS/31/2024-2025 Line 02Tender Authority
Public Works Department ViewPurchaser Address
-Website
http://eprocure.goa.gov.in
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
BOQ Items
... More
iv) Sides and Soffits of beams, Beam Haunchings, Cantilever, Girders, Bressumers and Lintels plinth beams not exceeding 1m in depth
249.2
412
102670.4
... More
Providing and laying in position (1:11/2:3) Reinforced cement conrete excluding the cost of centering, shuttering, finishing and reinfrocement (1 cement: 1½ coarse sand:3 graded stone agg 20mm nominal size)
-
-
-
... More
c) In beams, suspended floors, roofs having slope upto 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases upto floor five level
37.38
8109
303114.42
... More
Providing TMT steel reinforcement bars of (SAIL, TATA. VIZAG, JSW Steel Ltd.) ) (Confirming to IS 1786 of 1986) for RCC work (conforming to I.S. 1786 of 1986) including bending, binding & placing in position in all the floors along with the factory made precast concrete cover blocks of specified sizes whose compressive strength is not less than that of surrounding concrete in the structural member.
3738
105
392490
... More
Laterite masonry in neatly dressed stones for 23 cms thick masonry walls in c.m. 1 : 4 (1 cement : 4 coarse sand in foundation upto plinth level +Extra for laterite masonry in all sizes in superstructure from floor I level upto floor V level.
25.47
7004
178391.88
... More
Removing old loose bottom or side cover of RCC slab, beam, columns etc. rubbing surface of concrete steel using wire brush and applying 2 coats of Alkaline rust converting primer (Feovert) after a waiting time of 6 hrs between coats and then applying another anti corrosive protective coating system ) for reinforcement bars (IPNet-RB) Conforms to IS-2770 Part-1 (Pull out Test) ASTM-3963-86 (Adhesion Test) and then applying concrete penetrating corrosion inhibitor (EPCO-KP100) and applying bonding new to old concrete (Epibond) Conforms to ASTM-C-882-87 and plastering on the fresh bond coat with Polymer Modified Mortar (Monobond) with 20mm C.M 1:3 and finishing coat of 6mm C.P 1:3 (1 Cement : 3 Sand ) incl. cost of transport etc. as per dir of EIC. All the chemicals will be ofKrishna Conchem Products Pvt. Ltd. or Equivalent.
163.48
2086
341019.28
... More
Providing & fixing colour coated Alluminium (PUF) sandwich panel roofing systems of approved make adhering to Aluminium 3105 grade for top & bottom sheet of thickness 0.40 & 0.35 respectively including PUF insulation betewwn the top & bottom sheet of Denslity 40 (+/-2) Kg/m3 inclusive of S.S.304 grade self tapping fastneres, complete as directed by Enigneer incharge (frame work for roof, roof accesorries to be paid seperately) for tile Design PUF roof panel, Gutter width should be atleast 25% more than the Crest width. Minimum height at heighest point of Crest should be minimum 65mm. Minimum thickness at anygiven point should not be below 30mm.
-
-
-
... More
b) PUF Insulated tile roof 50mm thick of trapezoidal design
1258.4
2822
3551204.8
... More
Steel work welded (SAIL, TATA. VIZAG & using electrodes of Ador or ES4B or Deh Secheron make only)in built up sections trusses and framed work including cutting, hoisting, fixing in position and applying priming coat of red lead paint.
-
-
-
... More
b) In tees, angles, flats and channels
125.84
13023
1638814.32
... More
Providing & Fixing Alluminium Ridge of approved make adhering to Alluminium 3105 grade of 0.71mm thickness & 60 cm wide inclusive of SS304 grade self tapping fastners, to match the Alluminium roofing system & as directed by Engineer in charge complete
96.8
798
77246.4
... More
Providing & Fixing Alluminium 50mm Trapezhoidal End Cap for PUF Roofing of approved make of Alluminium AA 3105 grade matching with 50mm PUF panel profile including the required fastners etc. Complete for Alluminium PUF Roofing System & as directed by Engineer in charge.
193.6
252
48787.2
... More
Providing & Fixing Alluminium Corner flashing/ Gutter Valley of approved make Alluminium 3105 grade of 0.71mm thickness & 60 cm wide inclusive of SS304 grade self tapping fastners, to match the Alluminium roofing system & as directed by Engineer in charge complete
52
798
41496
... More
Painting two or more coats (excluding priming coat) with superior quality ready mixed paint for steel work of approved brand & manufacture in all shades on new work to give an even shade.
943.5
107
100954.5
... More
12mm cement plaster 1:4 (1 cement : 4 fine sand)
180.3
223
40206.9
... More
18mm cement plaster in two coats under layer 12mm thick cement plaster 1:5 ( 1 cement : 5 coarse sand) and top layer 6mm thick with cement plaster 1: 3 (1 cement : 3 coarse sand) finished with sponge.
306.2
329
100739.8
... More
Providing and fixing rigid PVC S.W.R. (soil, waste & rain water drainage pipes of approved including lubricant etc. complete (single/double) socketed:
-
-
-
... More
a) 110 mm dia
56
295
16520
... More
Providing and fabricating gutter of M.S. plate of 2mm thickness which is supported on M.S.angles of size ISA 65x65x7 MM under the plate in U-shape at distance of 3m c/c with supprot of the same section and supporting 4 angles under plate of size ISA65x65x6MM
52.4
5465
286366
... More
Painting three or more coats with acryllic exterior paint of approved brand and manufacture (Such as Dulex/ Asian Paints/ Sherwin Willians) including applying one coat of cement primer and one coat of surface treatment etc. complete.
306.2
208
63689.6