Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2024_NCAOR_836940_1Bid Award Id
ViewTender No
NCPOR/Estate/ET-02/2024-25Tender Authority
National Centre For Polar And Ocean Research ViewPurchaser Address
-Website
http://http://www.ncaor.gov.in/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
Item Description Painting and Waterproofing of buildings at NCPOR, Goa xl
BOQ Items
... More
Providing, mixing and applying two or more coats of crack seal of approved brand on cracked portion of RCC structures as per specifications and direction of Engineer-In-charge complete in all respect. Crack seal is to be applied on the roofs wherever cracks observed upto 3mm wide It should have strong filling capacity for cracks and should be water resistant and stop water ingress through cracks. The cracks are to be saw cut into ‘V’ grove, cleaned thoroughly and be saturated as per manufacturer’s standards before crack filler application. The forced coverage for crack filler application should be maximum 22 rmt/kg for 2 coats. The drying time for each coat should be 6 to 8 hours.
860
-
-
... More
Providing, mixing and applying Polymer modified repair mortar of approved brand on cracked and damaged portion of RCC structures as per specifications and direction of Engineer-In-charge complete in all respect. Repair mortar to be applied on the roofs wherever damage and cracks observed of more than 3mm wide. It should have strong filling capacity for cracks along with good water resistance and stop water ingress through cracks. The cracks are to be saw cut into ‘V’ grove upto 12 mm wide, cleaned thoroughly and be saturated as per manufacturer’s standards before repair mortar application. Note: Expansion / construction joints treatment is required at 04-05 roof locations in different buildings at NCPOR. The same to be finished with repair mortar, however, the procedure for treatment of the said joints, prescribed by the OPM, and as elaborated in the scope of work should be followed. The same to be considered while quoting for this item.
572
-
-
... More
Providing and applying fibre reinforced elastomeric liquid applied waterproofing compound in (Three coats (01 self-priming coat and 02 top coats)) to RCC structures with the help of synthetic fibre brush. The work shall be carried out all complete as per specification and the direction of the Engineer-in-charge. Application procedure (on horizontal surfaces) should include three coats of the waterproofing compound. Self-priming base coat with dilution 30%. First coat of waterproofing undiluted. Second coat of waterproofing undiluted. It should possess anti-fungal and anti-algal properties. It should possess excellent resistance to water, UV rays and ageing. The compound should provide a forced coverage of 0.9 sq.m / ltr. on horizontal & sloping surfaces and 3 – 3.5 sq.m / ltr. on vertical surfaces and should attain a thickness of 500 - 600 microns after the final coat.
5717.57
-
-
... More
Providing and applying cement-based ready mix mortar of approved brand on cracked or damaged portion of masonry wall plaster and on roofs of buildings for battens as per specifications and direction of Engineer-In-charge complete in all respect. Any major cracks or defects in the plaster shall be cut out in V shape with 12mm x 12mm grove and made good. Cracks may be wetted thoroughly prior to filling, to avoid undue absorption of water and subsequent shrinkage of the filling. The damaged roof battens should be repaired and should be of the same size and dimensions as per the existing ones. The damages include broken corners, cracks, broken edges, undulations in thickness and height, etc. The battens are to be provided with intermediate gaps (one above other) for allowing the smooth flow of percolated rainwater from the roof tiles.
1000
-
-
... More
Providing and painting (Three coats (01 base coat and 02 paint coat)) on old work with waterproof acrylic emulsion paint on external wall, applying coat of primer of approved make, color and shade to give an even finish, all as directed including all materials, labor, scaffoldings, brushers, tools, equipments, etc. complete as directed by Engineer in- charge. The product should provide superlative waterproofing capabilities and should form an effective barrier against water penetration. It should have higher elongation and should include fiber reinforcement thereby offering crack bridging ability of up to 2.4 mm at 175 - 225 microns. Application methodology: On old painted surface it should provide forced coverage of: 01 coat of basecoat covering 3.5 sq. m/ltr without dilution and 02 coats of topcoat 5– 6 sq. m/ltr (40% dilution). Location: External walls of all the buildings in NCPOR Campus. The buildings include Main building, lab block, fellow lab, auditorium building, guard office, canteen, sump and pump room, compound wall (fellows lab).
13819.44
-
-
... More
Providing & fixing on roof Mangalore clay tiles of 20 mm nominal thickness and of approved size and as per approved pattern on roof mortar battens as directed by Engineer in- charge. The roofing tiles shall be made from suitable clay of even texture and shall be well burnt. They shall be free from irregularities, such as twists, bends, cracks and laminations. The roofing tile shall be free from impurities like particles of stone, lime or other foreign materials visible to the naked eye either on the surface or on the fractured face of the tile obtained by breaking the tile. When the roofing tile is placed on either face on a plane surface, the gap at the corners shall be not more than 6 mm.
200
-
-
... More
Providing and painting with acrylic emulsion paint for two or more coats, of approved brand and manufacture, including applying additional coats wherever required, to achieve even shade and colour as directed by Engineer in- charge. The paint should have excellent water repellent property and provide excellent resistance against algal and fungal growth. It should have better adhesion on tiles, crack bridging abilities and provide a tough film. On normal surface by brushing, it should provide a forced coverage of 1 coat covering 9 -11 sq. m/ltr and for 2 coats 4 - 5 sq. m/ltr. with both coats having 30% dilution by volume (diluting agent – water). Drying time should be 4 to 6 hours for each coat. Note: This item would be executed for roof tiles.