Military Engineer Services Tender
View complete overview of Goa MES Tender
Costs
EMD
₹ 65,300Document Cost
₹ 500Tender Fee
Refer Documents
Summary
Provn Of Pathway With Shelter At Hq Gna Mess Lawn Provn Of Exterior Emulsion Weather Proof Anti Fungal Paint Of Bldg No 01 At Bws Provn Of 3 Phase 300 Kva Servo Voltage Stabilizer For Grid Supply And Ncn At Mo Goa And Provn Of Def Facilities At Noi
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2024_MES_688864_1Tender No
8682/E8Tender Authority
Military Engineer Services ViewPurchaser Address
-Website
http://http://mes.gov.in/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
BOQ Items
... More
M&L for plain cement concrete 1:4:8 type D-2 (using 40mm graded stone aggregate) as in foundation, filling & mass concrete complete all as specified and directed.
11
-
-
... More
M&L for precast cement concrete block masonry, type C-1 (1:3:6) (20 mm graded aggregate) with solid blocks, exc 10 cm in width and setting in CM 1:4 complete all as specified and as directed.
2
-
-
... More
M&L for plain cement concrete 1:3:6 type C-2 (using 40 mm graded stone aggregate) as in foundation, filling & mass concrete, for fixing of posts, sub base etc. complete all as specified and directed.
1.25
-
-
... More
M&L structural steel work in tubular trusses/framed work including special shaped washer etc complete using ERW or induction butt welded tubes and posts conforming to relevant IS grade St.-240 complete all as specified and directed.
2221
-
-
... More
S&F mild steel framed brackets of angles or tees with web and flanges cut to shape, drilled and countersunk for screw, including bending and welding angles, as necessary, gussets plates, riveting, etc. n exc 10 Kg each brackets, conforming to Fe-290. Gde-E-165 complete all as specified and directed .
75
-
-
... More
S&F 2 mm thick factory made galvanized Iron eaves gutter and pipe any description not exc. 60 cm grith including holder bats, distance pieces etc. complete all as specified and directed .
100
-
-
... More
M&L for preparation of new or previously untreated steel surfaces exceeding 10 cm width or girth and applying two coats of epoxy paint over a coat of epoxy primer all as specified and directed.
80
-
-
... More
M&L for pre painted galvalume aluminium zinc coating GI based corrugated steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding fixed with self tapping screws complete all as specified and directed.
205
-
-
... More
M&L for rendering on fair faces of brick work or PCC block masonary or concrete surface, 15 mm thick in two layers of 10 + 5 mm in CM 1:4 finished the surface fair and even complete all as specified and directed.
15
-
-
... More
M&L for preperation of new surface wall etc. applying a coat of alkali resistant primer and applying two coats of exterior emulsion paint complete all as manufacturers instructions and as directed.
15
-
-
... More
M&L for cement concrete 1:4:8 type D-2 (using 40 mm graded stone aggregate) 75 mm thick as in sub base or in levelling course, finishing the surface even and rough to receive floor complete all as specified and directed.
10
-
-
... More
M&L for Vitrified Ceramic tiles 9 to 10 mm thick light shade square/ rectangular polished, area of each tiles not exceeding 0.36 sqm as in floors etc., set and jointed in neat cement slurry and pointed in white or coloured cement to match over and including 20 mm thick screed bed in CM 1:4 complete all as specified and directed.
10
-
-
... More
M&L for providing and fixing stainless steel (Grade 316) railing made of hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (where ever required) and fitting the same with necessary stainless steel nuts and bolts complete, including fixing the railing with necessary accessories & stainless steel dash fasteners, stainless steel bolts etc., of required size, on the top of floor or the side of waist slab with suitable arrangement complete all as specified and directed.
206
-
-
... More
M&L for complete removal of exisitng treatment by means of using jet spray machine washing down existing treatment and preperation of old surface wall/ceilling by scrapping/ rubbing, applying two coat of advanced anti-algal weather proof 100% acrylic smooth emulsion with silicon additives, over a coat of fibre reinforced elastomeric liquid water proofing membrane (Asian paint damp proof + ultima suprema, exterior anti fungal paint or equivalent), on old plastered surfaces of walls/ceilling and cornires brooming down or steel wire brushing scrapping down with steel scrapper smoke soot moulds moss and efflorescent slats brading oil and greasy spots etc. and making proper surface by applying ready mix preparatory wall care putty wherever required complete all as manufacturers instructions and as directed. Note:- The application of paint shall be done by the authorized applicator of the company and also the dealer/company shall appoint a person to inspect and validate the application of emulsion in stage wise manner.
1242
-
-
... More
Excavation over areas n.exc 1.50m deep and getting out in soft/disintegrated rock complete all as specified and directed.
27
-
-
... More
Removing excavated material (Soils/Rock) to a distance exceeding 1.5 Km but not exceeding 5 Km and depositing where directed at a level n.exc. 1.5 m above the starting point complete all as specified and directed.
27
-
-
... More
Hardcore of broken stone or boulder gauge n. exc. 63 mm, deposited, spread & levelled in layers n.exc. 15 cm thick watered and rammed to a true surface complete all as specified and directed.
15.5
-
-
... More
M&L for cement concrete 1:4:8 type D-2 (using 40 mm graded stone aggregate) 100 mm thick as in sub base, finishing the surface even and rough to receive floor complete all as specified and directed.
90
-
-
... More
M&L for 60 mm thick factory made chamfered edge cement concrete paver block of M-35 grade with approved colour, design & pattern as in footpath, parks, lawns, drive ways or light traffic parking etc., of required strength, thickness & size/ shape, made by table vibratory method using PU mould, laid in required colour & pattern over and including 50mm thick compacted bed of fine sand, compacting and proper embedding/ laying of inter locking paver blocks into the sand bedding layer through vibratory compaction by using plate vibrator, filling the joints with sand and cutting of paver blocks as per required size and pattern, finishing and sweeping extra sand complete all as specified and directed.
90
-
-
... More
M&L for PCC 1:2:4 type B-1 (using 20 mm graded stone aggregate) as in coping etc. including necessary form work complete all as specified and directed.
5
-
-
... More
Excavation in trenches not exceeding 1.5 m wide and not exceeding 1.5 m deep in hard/dense soil for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. n exc 10 sqm on plan and getting out complete all as specified and as directed.
116
-
-
... More
Returning filling in including spreading watering and well raming in layer not excedding 25 cm each in any type of soil/rock complete all as specified and directed.
147.5
-
-
... More
Removing excavated material (Soils/Rock) to a distance not exceeding 50 m and depositing where directed at a level n.exc. 1.5 m above the starting point complete all as specified and directed.
13.3
-
-
... More
Supply & laying (DWC) HDPE full rounded pipe having corrugated outside and inner side plain conforming to IS 16205 Pt-24 of approved colour complete with fittings for cable protection of size 38 mm inner dia and 50 mm outer dia complete all as directed.
350
-
-
... More
S&L XLPE LT UG cable PVC insulated, bedded armoured heavy duty electric cable 1100 volts grade with aluminum conductor of 95 Sq mm 3.5 core laid in trenches or fixed on wall/floor/poles complete all as specified and directed.
180
-
-
... More
S&L XLPE LT UG cable PVC insulated, bedded armoured heavy duty electric cable 1100 volts grade with aluminum conductor of 16 Sq mm 4 core laid in trenches or fixed on wall/floor/poles complete all as specified and directed.
291
-
-
... More
M&L for earthing complete with galvanised steel plate electrode 600mm x 600mm x 6mm thick buried directly in ground (earth pit not less than 2.25 Mts deep below ground level with top edge of the plate not less than 1.50 Mtrs below ground level connected to glavanised iron strip 25 x 4 mm by means of bolts, nuts check nuts and washers of galvanised iron or steel connected to earthing test point all as specified incl GI tubing medium grade and necessary fitting for protection of GI wire incl laying of charcoal dust and common salt in alternate layer, PCC Pit (1:3:6) type C-1 using 20 mm graded stone aggregate, RCC cover 40mm thick (1:2:4) type B-0 using 12.5 mm graded stone aggregate reinforced with 6 mm dia round bar @ 75 mm C/C both ways with MS handle 8 mm dia, plastering 15 mm thick CM (1:6) externally upto 150mm below ground level, GI funnel with 20mm dia medium grade GI pipe for watering and wire mesh incl. excavation and earth work and disposal of surplus soil complete all as specified and shown on electrical plate No 3 of SSR Part (2009) and connected to earth test point incl testing complete all as specified an directed.
Note:- The unit rate includes the cost of GI pipe medium grade for protection of earth wire and earth strip upto 7.5 M.
4
-
-
... More
Supply, installing, erecting, commissioning and testing factory made LT panel board cubical out door type of suitable size for housing of all equipments & proper heat dissipation, CPRI approved weather/dust proof, made out of 3.15 mm thick CRCA sheet powder coated with front openable with suitable cable chamber and front side double shutters with locking arrangement, panel base of angle iron 50x50x6 mm upto 60 cm height for ground level, 433 volts, 3 phase, 4 wire system. All interconnections between the main bus bar as well as outgoing feeders shall be carried out with TPN Aluminium bus bar 400 Amp. All control wiring shall be with FRLS PVC insulated 6 sqmm multi-stranded copper conductor and shall be properly bunched. The panel board shall have bottom channel of size 75 x 40 mm and complete mounted or fixed on PCC foundation 0.45 mtr above floor and cable connection with suitable size of copper lugs and suitable size chrome plated glands provided for incoming and out-going cables comprising the following :-
INCOMING MCCB
a) 350 Amp 4 pole MCCB 36 KA breaking capacity with adjustable thermal magnetic setting with earth fault protection and rotary handle Ics= 100% Icu-01 Nos. OUTGOING MCCB
a) 160 Amp 4 pole MCCB 16 KA breaking capacity with adjustable thermal magnetic setting with rotary handle Ics= 100% Icu - 04 Nos. b) MCB TPN 63 Amp -04 Nos. b) 63 Amp SPN MCB, 10 KA, 'C' curve, 230 V - 02 No. c) Space for spare MCCB/MCB
Metering:
a) AC digital voltmeter 0-500 volts Size 4"X4" with 3 Ph selector switch-01 Nos
b) 0-500 digital Amp meter with suitable Size 4"X4" with 3 Ph selector switch- 01 No.
c) LED Indicating lamps RYB set of three -01 Sets
The manufacture shall submit a copy of TESTREPORT of CPRI approved.
1
-
-
... More
M&L for removing old Electric poles including clamps, demolition of foundation and depositing to MES store yard complete all as specified and directed.
1
-
-
... More
Supply, fixing, laying & testing 40 mm dia (Nominal bore) galvanised iron water tubing 'medium grade' with and including all GI fittings such as flanges, unions, reducer sockets, socket reducing bends, elbows, tee, checknuts, caps, plugs etc. fixed complete to walls and ceilings or laid in trenches, floors complete all as specified and directed.
300
-
-
... More
Supply, fixing, laying & testing 25 mm dia (Nominal bore) galvanised iron water tubing 'medium grade' with and including all GI fittings such as flanges, unions, reducer sockets, socket reducing bends, elbows, tee, checknuts, caps, plugs etc. fixed complete to walls and ceilings or laid in trenches, floors complete all as specified and directed.
18
-
-
... More
S&F Gun metal globe or gate valve ISI marked with iron wheel head screwed both ends for pipe of size 25 mm bore complete all as specified and directed. Make:- Kirloskar/ Zoloto/ BIR/Leader.
2
-
-
... More
S&F Gun metal globe or gate valve ISI marked with iron wheel head screwed both ends for pipe of size 40 mm bore complete all as specified and directed. Make:- Kirloskar/ Zoloto/ BIR/Leader.
1
-
-
... More
Cutting of existing GI/Steel/CPVC/CI tubing of 50/40 mm dia/size in position for taking branch connection including insertion of new tee, elbow, reducer etc. equal and any other accessories as required at site including excavation, removal, returning filling complete all as specified and directed.
2
-
-
... More
M&L for 300 KVA capacity servo controlled voltage stabilizer (conforming as per BIS : 9815 : Part-1 : 1994 reaffirmed 2009) for automatic operation, three phase, naturally oil cooled outdoor type, Unbalanced type, copper wound, digital display, relay free smooth and silent operation designed for input variation Voltage between 300 V to 480 V with output voltage stabilized at 415 V with accuracy + 1 % and speed of correction 8 Volts per second and 20 volts per second for phase to phase, digital display Voltmeter/ Ampmeter, overload/ Short circuit protection, high/low voltage cut off, by pass arrangement in case of emergency, single phase sequence change protection including first filling of oil in servo Voltage stabilizer including testing on completion complete all as specified and directed. Make:- AE/ Vinitek/V Guard/Volina/ Sinetrac
1
-
-
... More
S&L XLPE LT UG cable PVC insulated, bedded armoured heavy duty electric cable 1100 volts grade with aluminum conductor of 35 Sqmm 3.5 core laid in trenches or fixed on wall/floor/poles complete all as specified and directed.
30
-
-
... More
S&L XLPE LT UG cable PVC insulated, bedded armoured heavy duty electric cable 1100 volts grade with aluminum conductor of 300 Sqmm 3.5 core laid in trenches or fixed on wall/floor/poles complete all as specified and directed.
59
-
-
... More
M&L for local fine sand cushioning with dry and clean over and under the cable for protection of cable, 80 mm sand laid before laying the cable 150 mm sand after laying the cable and punned down complete all as directed
4
-
-
... More
Supply and laying un-reinforced precast concrete cable cover factory made as per IS 5820-1970, class LV type 1 of size 250 mm x 150 mm x 40 mm as in cable protection complete all as specified and directed.
300
-
-
... More
Supply, fixing & laying 80 mm dia (Nominal bore) galvanised iron water tubing 'medium grade' with and including all GI fittings such as flanges, unions, bends, elbows, tee etc. fixed complete to walls and ceilings or laid in trenches, floors for cable protection complete all as specified and directed.
6
-
-
... More
M&L for earthing complete with copper plate electrode 600mm x 600mm x 3.15 mm thick buried directly in ground (earth pit not less than 2.25 Mts deep below ground level with top edge of the plate not less than 1.50 Mtrs below ground level connected to copper earth strip 20 x 3 mm by means of bolts, nuts check nuts and washers of brass connected to earthing test point all as specified incl laying of charcoal dust and common salt in alternate layer, PCC Pit (1:3:6) type C-1 using 20 mm graded stone aggregate, RCC cover 40mm thick (1:2:4) type B-0 using 12.5 mm graded stone aggregate reinforced with 6 mm dia round bar @ 75 mm C/C both ways with MS handle 8 mm dia, plastering 15 mm thick CM (1:6) externally upto 150mm below ground level, GI funnel with 20mm dia medium grade GI pipe for watering and wire mesh incl. excavation and earth work and disposal of surplus soil complete all as specified and shown on electrical plate No 5 of SSR Part (2009) and connected to earth test point incl testing complete all as specified an directed.
4
-
-
... More
S&F earth continuity conductor or main earthing lead of 16 Sqmm PVC insulated copper conductor drawn in through PVC conduit/ pipe and fixing from existing earthing to distribution box complete all as specified and directed.
20
-
-
... More
M&L for plain cement concrete 1:3:6 type C-2 (using 40mm graded stone aggregate) 100 mm thick as in flooring, foundation of tank etc. finished even and smooth without using extra cement complete all as specified and directed.
2
-
-
... More
S&F roof trussed framed, trussed, purlins, crane gantries, rails and fastenings and heavy brackets framing (Beam, tee, angles, channel or flat sections) including distance pieces, cleats etc. (Fe- 410-W (Gde E-250 quality) complete all as specified and directed.
500
-
-
... More
M&L for preparation of new or previously untreated steel surfaces exceeding 10 cm width or girth and applying two coats of anti corrosive paint over a coat of red oxide zinc chrome primer all as specified and directed.
10
-
-
... More
M&L for precast cement concrete block masonry, type C-1 (1:3:6) (20 mm graded aggregate) with solid blocks, exc 10 cm in width and setting in CM 1:6 complete all as specified and as directed.
5
-
-
... More
M&L for rendering 15 mm thick on fair faces of brick work or concrete surface in cement mortar 1:6 finished even and smooth without using extra cement complete all as specified and directed.
20
-
-
... More
M&L for applying two coats of cement base paint over a coat of alkali resistant primer on new surfaces of walls including preparation of surface complete all as specified and directed.
19
-
-
... More
M&L for pre painted galvalume aluminium zinc coating GI based plain steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding fixed with self tapping screws complete all as specified and directed.
3
-
-
Evaluation Notes How It Works ?
Potential Partner
Select Your Requirements
Past BiddersThis list is curated from the bidders of the similar tenders in the past
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%