Konkan Railway Corporation Limited Tender

Download documents of Goa KRCL Tender

Konkan Railway Corporation Limited - KRCL Tender

Works
Electrical and Electronics
Electrical Works
Ireps
Opening Date5 Mar 2025
Closing Date28 Mar 2025
Tender Amount₹ 2,77,60,029.79 
Notes
Download

Costs

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
Disconnecting and Earthing device, 8 pole, 2 Way with ON-OFF, ON LOAD,125 AMPS 4 750 V (1000 V insulation) 2 No+ 2NC with heavy duty handle and pad locking arrangement in earth position mounted in a stainless steel enclosure suitable for AC 230 Duty Confirming to IS: 13947/IEC 947 as per L&T (Salzer) Cat No.73342SLB32LOGBBS or M/S SCHALTBAU cat No.M137-0827407 for LHB AC coaches.

4

45840

183362.36

... More
Disconnecting and Earthing device, 8 pole, 2 way, No-OFF, on load 63 Amps, 750 V AC 5 (1000V Insulation), 4 NO auxiliary contact, with heavy handle and pad locking arrangement in earth position without sheet steel/Stainless Steel enclosure for AC- 23 duty conforming to IS-13947/ IEC 947 as per RCF spec. EDTS355(Rev-1),similar to Salzer (L&T) make cat no.63A S63-73342-B03- LOGBS/Kaycee make cat.no.63808920A2 /4V490X. (TL COACHES).

10

15900

159000

... More
HRC fuse, Tubular type, 2 Amp, 1.2 KV AC suitable for use in Power Panel (HT side) of 6 LHB variant EOG Coaches as per drawing no. PCEE/GS/2 AMP FUSE/02 and confirming to RDSO Specification no. RDSO/PE/SPEC/AC/0184-2015 (Rev. 0) or latest and RDSO Modification letter no. EL/7.1.108/SBC dtd. 16.10.2018. Accepted make: Similar to category no. 184000.2 of SIBA / HVW-IR (2 Amp) of BUSSMANN (ETN).

200

195

39000

... More
LED Type Flashing Tail Lamp for LHB Type Power Car with Flashing Unit System and 7 VHF Charging Socket as per RCF Drg. No. LP-75001 and LP-73200, Alt No.-C and conforming to RCF Specification No. EDTS-215 (Rev.-Nil) with Amendment 1. [ICF ID-2300060 / RCF ID-2400017 / MCF ID- 2700026] (Rev.-Nil) with Amendment 1. EATON BUSSMANN

10

13278

132780

... More
Double inlet Centrifugal Blower assembly complete with mounting brackets suitable for 8 exhaust fan in LHB type coaches, type - double inlet centrifugal blower speed: 1500 RPM, Air Volume: 625 CMH, power input: 200 W, current: 0.4 Amps, Voltage: 415 V 3 phase AC, Frequency: 50 Hz, conforming to RCF specification No. EDTS 331,Amendment-1, type -1, Corr.1,2 & 3. Accepted brand: INTEG. SEM or similar.

30

5498

164940

... More
Power Contactor 100 Amps, 415 Volt, 4 Pole, Duty AC-1, Operating Coil Voltage 48-130 9 Volt AC/DC, 50/60 HZ/DC with Auxiliary Contact Block (Front Mounting) 2 NO.+ 2NC. and surge suppressor diode. Make ABB,Model No. AF50-40-00-Coil Code 70 with Auxiliary Contact Block CA5-22E or equivalent make of Schneider / Siemens or latest Railway approved make suitable for Switch Board cabinet of Non AC LHB Coaches.

20

7200

144000

... More
Supply of high voltage fuse link rating - 25 amps ,volt- 1000,VAC, breaking capacity - 120KA for use in LHB non AC-coaches as per RDSO spec no. EDTS 355 rev -.1 or latest . Makes: Siba, Eaton / Bussman / Efeen / Ferraz / ETI / Siemens / Schneider / L&T.

50

1150

57500

... More
DC to DC converter for switch gear cabinet of LHB AC coaches -110/24 V, 240W,10A confirming to RDSO SPEC.NO.RDSO/PE/SPEC/AC/0184-2015[REV O] MAKE:-ABB PART NO.CP-C-24/10 OR EQUIVALENT OF COSEL / POWERTECH / ASTEC / PHOENIX.

6

5853

35118

... More
Inter vehicular coupler Unit ( 500 Amp. rating ) for EOG LHB type AC coaches / Power car conforming to RDSO Specification No. RDSO / PE / SPEC / AC / 0177 (Rev.0) - 2013.

4

221400

885600

... More
Metering Transformer capacity 300 VA, 750V/415V/110V AC, 3 phase TYPE-RG-36/82/7- 13 TP suitable for LHB power cars. material is of M/S. BHASIN PACKARD PART NO. RG-36-82-7 TP OR M/S.VIMAL/PANTRONICS/HACEL/RAMAYA Electro Gear transformer as per RDSO specification no.EDTS- 103, REV. D, AM-7.

4

8380

33520

... More
Digital Voltmeter with LED display size 96 sq. mm, 0-800 V AC, CL1, True RMS, Aux. 14 supply- (12-48 V DC), 4 digit, 3 line, 7 segment display. Make- YOKINS, model no.-Y-9-3V3 or similar specification as per RDSO/SPEC/PE/TL/0195-2019(REV.0). MAKE- AE/Muller+Zeigier/Rishabh/L&T/YOKINS or similar in specification.

2

1574

3148

... More
Voltage measuring Transformer/metering Transformer: 750/415V, 3 phase, 50Hz, AC, Capacity: 300 VA, suitable for metering purpose in LHB type EOG power cars. Type: RG-36-82-7-TP. Make: Bhasin Packard, Vimal,Pantronics, NACEI, Ramya Electro gear.

4

7555

30220

... More
Set of various rotary switches used in switch board cabinet (SBC) of LHB AC coaches. one set consist of 01 Nos Ammeter selection rotary switch, 01 Nos voltmeter selection rotary switch, 01 Nos Feeder selection rotary switch and 01 Nos power supply on/off switch i.e. 4 items and 4 Nos. Material is as per RDSO Specification No.RDSO/PE/SPEC/0184-2015( Rev-1). Details are as follows: 1)Ammeter selection rotary switch with marking " L1-L2-L3 ". Rotary switch is M/s. Siemens part no. 3ST1400-2RQ08 of M/s.L&T or M/s. Salzer.One SBC contain 01 Nos of Ammeter selection rotary switch. 16 2) Voltmeter selector switch with marking L1-L2, L2-L3, L3-L-1 rated voltage 1000 VAC. Material is M/s.Siemens part no. 3ST1400-1RK08 or M/s.L&T or Ms.Salzer. One SBC contains 2 Nos.of Voltmeter selection rotary switch. 3) Feeder selection rotary switch with marking "I-O-II" net1-local main supply net2 (Change over switch with O-position 3 pole rated voltage 690V AC, rated current 16A. Rotary switch is M/s.Siemens part no. 3SB50002DB01 + 3SB5400-OA or M/s. L&T.One SBC contain 1 nos of feeder selection rotary switch. 4) Toggle Switch 0-1 power supply on/off switch with socket and 2 NO is M/s.Siemens part no. 3SB50002AB01 + 3SB5400-OE or M/s. L&T or M/s.Salzer. One SBC contains 01Nos of power supply On/Off switch. Accepted makes : L&T, Siemens,GE.

2

900

1800

... More
A set of Rotary switches consist 03 items:(1) Rotary switch equivalent to L&T Salzer make part No. 6AS6- ASS-B13-TDYR Suitable for Ammeter phase selector ( R, Y, B )-01 No ( 2 ) Rotary 17 Switch equivalent to L&T Salzer make Part No, 6A-S6-61006-B13-TDYR suitable for ON/OFF switch in Switch Board Cabinet ( SBC) of LHB AC coach-3 Nos. and (3) Rotary switch with marking I-0-II Net-1- Local main supply- Net-2 ( change over switch with OFF coach-3 Nos. and (3) Rotary switch with marking I-0-II Net-1- Local main supply- Net-2 (change over switch with OFF position 3 pole) equivalent to L&T Salzer make part No . 6A-S6 61090-B13- TDYR suitable for Net selection in the SBC- 3 Nos.. Make-L&T-Salzer, Siemens, Schneider.

6

945

5670

... More
72 X 72 mm Front Panel voltmeter range 0-150 DC Volts, flush type with rubber gasket accuracy class 1.5 as per IS :248 (P-2)-2003, NW-72, suitable for LHB AC coaches. Accepted makes : AE / MULLER / ZEIGLER / RISHABH/YOKINS/L&T.

6

449

2694

... More
Ammeter NP-72, 0 to 100A: 200A, Cl.1.5 for current transformer 100/1A, size 72x72 19 mm analog type, as per serial no. 12 item no. P01 of bill of material of RDSO spec. no.- RDSO/PE/SPEC/AC/0184-2015(REV.0) suitable for use in switch board cabinet of LHB TYPE AC COACHES. MAKE - YOKINS

6

255

1530

... More
Ammeter Selector Switch Knob-B Engine (SBC 2 Cabinet ) as per Salzer model no:16A- S16-61325- TDYR . Make: Salzer (L&T) or Kaycee for LHB Power Cars.

6

250

1500

... More
Analog DC Ammeter NP-72 for battery 50A-0-50A, size 72 X 72mm as per serial No.129 of Bill of material of RDSO. Spec. No. RDSO/PE/SPEC/AC/0184-2015(REV.0) suitable for use in Switch Board Cabinet of LHB type AC coaches. Accepted Makes : Yokins / Zeigler / Rishabh / L&T.

6

350

2100

... More
Analog Voltmeter 0-1000 V, NW72 square panel mounting type, AC insulation class CI- 22 1, accuracy: 1.5%, size 72mmx72mm with 750V marking, suitable for fixing in LHB AC coaches switch board cabinet as per RDSO spec. : RDSO/PE/SPEC/AC/0184-2015, Rev.1, RDSO approved makes: AE / Rishabh / Muller + Zieghfer / L&T / Yokins.

6

338

2031

... More
Din Rail Mounted Earth Leakage Relay (Residual Current Monitor Relay) With Operating 23 Voltage 12-48 V AC/DC, Confirming To IEC 62020-1, Suitable For SBC 2 Of LHB Power car. Type / Make RCM470ly-21 of Bender or Elr-3c Of Fanox Or Rd3m-48 Of Abb As Per RCF Specification EDTS-103 Rev-D AM-4 .

6

7000

42000

... More
Single phase Emergency Battery Charger (EBC) for EOG Type LHB coaches as per RCF 24 specification No. EDTS 163 Rev. C, corrigendum-4 or latest. Rated capacity 2.5KW current rating-20 Amp input voltage-230volts AC . Out put voltage 110 volts DC Make-ICF/MCF/RCF/RDSO approved only.

4

21500

86000

... More
A set of spares of M/S BHASIN PACKARD make emergency battery charger, single 25 phase, 50hz, for EOG type LHB AC coaches as per RCF specification no. EDTS-163 rev ' C ' corrigendum - 4 or latest, Material to be procured from OEM only, are as follows:- 1) PCB control card : EBC-310-1A qty. = 01 no/set 2) Display meter, suitable for emergency battery charger EDTS-163 qty. = 04 nos/set (one set consists of 02 items and qty 05 nos)

6

11105

66634.8

... More
Digital frequency meter with LED display, size-96 sq.mm. for measuring frequency, 26 suitable for voltage- 50-550V AC, 50 HZ, CL 0.2, True RMS, Aux. supply-(12-48 V DC), 4 digit, 3 line, 7 segment display, Make- YOKINS, model-Y-9-3HZ. or similar in specification. as per RDSO/SPEC/PE/TL/0195-2019(REV.0). Make- AE/Muller+Zeigier/Rishbabh/L&T/YOKINS or similar

2

1369

2738.18

... More
Multifunction energy meter with LCD display in 96x96 Sq.mm flush mount, 27 measurement, i.e., VI, HZ, P, PF, max, Avg, H, e, etc., 4 lines display suitable for DG set power panel of LHB power car. Make: Socomec, Model No.DIRIS A40. or Rishab make, Model No.LM 1360 or equivalent.

2

4150

8300

... More
Set of various meters used in LHB power car. A set contains 03 nos of voltmeter, 01 nos of Multifunction energy meter, 01 nos of ammeter i.e. 3 items & 5 in nos. as per as per RCF 28 specification no. EDTS 103, REV-D, AM-7 or latest. Material make is L&T/ AE/ SOCCOMEC / RISHABH/ SIEMENS / SCHNEIDER/ YOKINS or MULLER only. Quantity- 02 set (03 items & 10 in nos). Details are as follows 1) Ammeter NP72, class 1.5, CT 400/5A, scale 0%u2026.400/800A. As per RCF specification EDTS 103, Rev-D, Amd-7, make should be of L&T/ AE/ SOCCOMEC /RISHABH/ SIEMENS / SCHNEIDER/ YOKINS or MULLER. One power car contains 02 nos of ammeter. 2) Multifunction energy meter 5A or 1A CT input for LV or HV networks AC or DC Aux. Supply measurement & display UVI In PQSPFFEa, Er, & Es THD for V&I with lead bar graph in 96*96 sq. mm. flush mounted case with six direct access key & backlit LCD, accuracy class 1.0 as per RCF specification EDTS 103, Rev-D, Amd-7 or latest. Material make should be of M/s. AE part No. DIRIS A40 or equivalent part no. of L&T/ SOCCOMEC / RISHABH/ SIEMENS / SCHNEIDER/ YOKINS or MULLER only. One power car contains 02 nos of multifunction energy meter. 3) Voltmeter NW72 net1, 0-800V, 800 VAC as per RCF specification EDTS 103, Rev-D, Amd-7 or latest. Material make should be o f L&T part no. NW72( Net-1) 0-800V, 800V AC or equivalent part no. of AE/ SOCCOMEC / RISHABH/ SIEMENS / SCHNEIDER/ YOKINS or MULLER only. One power car contains 0MAKE6 nos of this kind of voltmeter. Accepted offer AE

4

13379

53516

... More
Earth fault Relay 110V DC (Voltage Type) EFRA-II. Pick Up Voltage 50 Volt DC, Aux. 29 Voltage 110 Volt DC. ENGLISH ELECTRIC/ALSTOM Type: VAG Model NO.: SPECM 2YF328M (VAG11/VAA11) OR IT'S EXACT EQUIVALENT. M/S GEC type VAG Model No. SPEC M2YF 328M Spec: M/S GEC type VAG Model No. SPECM2YF328M.

2

8000

16000

... More
Solid state relay for control safety loop, DC3-32 V confirming to RCF specification no. EDTS 103 Rev-D, Am-7. Material is RD0605-D of M/s Carlo Gavazi (as per EDTS 103 BOM).

2

11500

23000

... More
RC Filters for HOG power supply system in LHB EOG AC and Non AC coaches as per RDSO modification sheet No. RDSO/PE/MS/AC/0051-2011, Rev-2, amendment 1. Brands: Bhasin Packard/NACEI/AEL/RAMYAA/TROLEX/ ABROL/NEC/ISG/TRINITRON

4

1450

5800

... More
Set of three RC(resistance capacitance) filter,Each RC filter consist of 01 OHM, 10 watt resistance connected in series with parallel connected 1.5 MFD, 850/1000V range capacitor 32 (epcos/vishay or equivalant),in each ARM of Star connected to be provided between phase & earth of 60KVA transformer as per Drawing no- RDSO/PE/SK/AC/0155-2015 rev-0 or latest of Siemens,medha,ramyaa or Similar with mounting arrangement as per Sheet no-2 of RDSO drawing no -RDSO/PE/SK/AC/0188-2015 rev-0 or latest Accepted Make/Brand-SURE or Similar Offered make- INTEG. Firm to submit GC and TC of product alongwith supply.

4

1388

5552

... More
CAPACITOR BANK FOR LHB EOG/HOG TYPE POWER CAR as per Spec.No. EDML130, REV-1, COR- 6 , TYPE-2, Packing Instruction - PI042 VER1.0

5

15999

79995

... More
PUSH SWITCH (DPB/5 (AIRON) suitable for MB & Company make Emergency Battery Charger (EBC), suited to LHB (EOG) type AC coaches as per RCFs Specification No. EDTS-163, Rev-C, Corrigendum-3 or latest. Make: MB & Company / Bhasin Packard / Electrowaves / Stesalit.

10

130

1300

... More
200VA CONTROL TRANSFORMER 750/415V, TYPE-II, , 50Hz, SINGLE PHASE' "H'' CLASS INSULATION, DRY TYPE & AIR COOLED, ALONG WITH FUSES COMPLETE, SUITABLE FOR SWITCH BOARD 35 CABINET OF EOG LHB TYPE AC COACHES CONFIRMING TO RDSO SPECIFICATION No. RDSO/PE/SPEC/AC/0203-2020 (Rev-0). ACCEPTED MAKE AS PER RDSO LETTER NO. EL/7.1.108/SBC/MAIN FILE, DATED 16,04,202I ARE AS UNDER :- BHASIN PACKARD, NACEI , TROLEX, RAMYAA, TRINITRON, KONTACT CONSORTIUM, ABROL, ASK POWERTEC OR ANY RDSO APPROVED MAKE

20

7500

150000

... More
Din type HRC fuse link 125 Amps breaking Capacity 25 KA at 1000V AC of M/s Ferraz make (1051 CP GLB 20.127 125 - X095700J) or SIBA (Type NH00M,NH1L,gb, part No: 2038903.125) or EFFN or ETI make confirming to IS 13703/IEC-269-2 suitable for use of LHB variant EOG coaches.

25

1425

35625

... More
High voltage HRC Fuse base/holder suitable for din type HRC fuse used in LHB AC 37 coaches, with current rating 125 Amps, voltage rating 1000 Volts, braking capacity 80 KA, size NH1L, Category GB, suitable for fitment with existing fuse of dimension similar to SIBA Catalogue no. 2028003.125, place of installation SIF50 to SIF55 of switch board cabinet of LHB AC coaches. Acceptable makes : SIBA, EFEN, Ferraz, ETI, Eaton Bussmann

10

750

7500

... More
200 AMPS 4 POLE POWER CONTACTOR FOR 750 VOLT AC AS WELL AS 415 VOLT AC APPLICATION HAVING CONTROL COIL OF 415 VOLT AC WITH ADDITIONAL SIDE MOUNTING 2 POLE AUXILIARY CONTACT, SUITABLE FOR LHB COACHES SIMILAR to MAKE: ABB, TYPE CODE:EK110-40-11- AR (FOR MAIN CONTACT WITH CONTROL COIL), CAL16-11A (FOR AUX. CONTACT). Accepted Make/BRAND:SCHNEIDER ICF/MCF/RCF approved sources only

-

-

38

... More
Contactor 3 Pole, 16 Amp capacity suitable for 415V, 50 HZ AC, coil voltage 110 DC with surge suppressor ( coil voltage range 77-137 v dc) with inc auxiliery contact block similar to ABB CODE TAL-16-30-01, RT 5/150 generally conforming to IS- 13947 PT.- 4/1993.]

6

1194

7166.1

... More
Power Contactor 12 Amps, 415 V, 50 HZ, 4 Pole, AC-3 duty, operating coil voltage 110 40 Volt DC (77-137 V DC), with Surge Suppressor Diode 77V-150DC, and Auxiliary Contact Block (Front Mounting) 2 NO + 2NC. Make ABB, Model No. TAL-16-40-00 with Auxiliary Contact Block CA5-22E & Surge Suppressor RT5/150 or SCHNEIDER Make Cat No-LCID125FD or SIEMENS Make Cat No-3RT1317- 1BF40, Suitable for Switch Gear Cabinet of LHB AC Coaches.

6

1875

11250

... More
415 volt,50Hz, 3 pole,9 AMPS,AC 3 duty,operating coil voltage 110 volt DC(77- 41 137),power contactor, with surge suppressor diode 77V-150DC,and auxilary contact block(front mounting)1 no.+1 NC of M/s ABB Make TAL-16-30-01 auxiliary contactt block CA5-01 and CA5-10, surge suppressor RTS/150,or SCHNEIDER -LC 1 D9 FD or SIEMENS 3RT 1016-1JF 42 with auxiliaries,surge suppressor suitable for switchgear rake of LHB AC coaches.

6

1075

6450

... More
Power Contactor 750 Amps, 1000V, 3 pole AC- 3 duty with coil voltage 250-500V, 50/60 42 HZ/DC (Code- 71) and Auxiliary contacts (1 NO+ 1 NC) suitable for switch board cabinet of LHB AC power car, confirming to RCF Spec. No. EDTS 103-Rev-d, Am-7. Make: ABB, Part No. AF750-30-11, Order Code: 1SFL637001R7111. as per Specn. RCF SPEC NO. EDTS 103-REV-D, AM-7.

6

67080

402480

... More
Analog voltmeter 0-1000 V, NW72 square panel mounting type, AC insulation class CI- 43 1, accuracy: 1.5%, size 72mmx72mm with 750V marking, suitable for fixing in LHB AC coaches switch board cabinet as per RDSO spec. : RDSO/PE/SPEC/AC/0184-2015, Rev.1, RDSO approved makes: AE/Rishabh/Muller+Zieghfer/ L&T/Yokins.

12

359

4308

... More
HOG A&B Main power contactors 3 Pole 1000 V AC, 50 Hz, Suitable for 500 KVA 750 V AC on load switching under AC 6A category at temperature of 70 Degree C and coil voltage of 415 v + 44 10 % - 20% AC with surge suppressor 2 NO + 2NC as per RDSO Spec No: RDSO/PE/SPEC/D/TL/0195- 2019 (Rev-0) Suitable for switch board cabinet for HOG Complaint LSLRD Coaches make (As per RDSO Spec bill of material)- ABB Model No; AF1250-30-11, L&T Model No: MVO 820, SIEMENS Model No; 3TF69448 CQ 7Z A 02,

4

119778

479112

... More
Feeder 1,2 and Bus coupler power contactors S2 K1, S2 K2, S2K3, 3 Pole 1000 V AC 50 45 Hz Suitable for 500 KVA 750 V AC on load switching under AC 6A category at temperature of 70 Degree C and coil voltage of 110 v + / - 25% -30% DC with surge suppressor 2 NO + 2NC as per RDSO Spec No: RDSO/PE/SPEC/D/TL/0195-2019 (Rev-1) or latest Suitable for switch board cabinet for HOG Complaint LSLRD Coaches make ABB, L&T , SIEMENS , SCHNEIDER only.

4

119500

478000

... More
Set of LSLRD HOG Panel LED indicating lamps with i). diameter 22.5, 24 VDC, Colour Green 100 Nos, White 100 Nos, Red 100 Nos, Amber 100 Nos, corresponding to RDSO specification No: RDSO/PE/SPEC/D/TL/0195 2019 (Rev-0) or latest. Approved Makes/ Model SIEMENS 3SB52856 (HE 46 01, HG 01, HC01, HL01, L&T (EPLG024C, EPLW024C, EPLR024C, EPLA024C) or equivalent in ESBEE/ TEKNIK/ SCHNEIDER only accepted. ii). diameter 22.5, 110 VDC, Colour Green 50 Nos, White 50 Nos, Red 50 Nos, Amber 50 Nos, corresponding to RDSO specification No: RDSO/PE/SPEC/D/TL/0195 2019 (Rev-0) or latest. Approved Makes/ Model SIEMENS 3SB52856 (HE 04, HG 04, HC04, HL04, or equivalent in L&T, ESBEE/ TEKNIK/ SCHNEIDER only accepted.

1

43000

43000

... More
Spare coil suitable for ABB make Model No: AF1250-30-11 Feeders 1 &2 and bus coupler, Power contactors, 3 pole, 1000 V AC, 50 Hz suitable for 500 KVA 750 V AC on load switching 47 under AC 6A category at temperature of 70 Degree C and coil voltage of 110 v + / - 25% -30% DC with surge suppressor 2 NO + 2NC as per RDSO Spec No: RDSO/PE/SPEC/D/TL/0195-2019 (Rev-0) Suitable for switch board cabinet for HOG Complaint LSLRD Coaches. Material should be supplied along with OEM proof of purchase, test certificate, make ABB, Product ID 1SFN156170R6906

4

41459

165839

... More
CURRENT TRANSFORMER 600/5 AMPS INSULATION LEVEL 0.813 AS PER IS 2705 / 1992 OF MAKE YOKINS OR ANY RDSO APPROVED MAKE.

-

-

1

... More
ROTARY SWITCH 4 POLE 4 WAY 32 AMPS 415 VOLTS OF SALZER MAKE OR ANY RDSO APPROVED MAKE.

6

1600

9601.32

... More
ROTARY SWITCH 4 POLE 4 WAY 16 AMPS 415 VOLTS OF SALZER MAKE OR ANY RDSO APPROVED MAKE.

6

1428

8570.7

... More
ROTARY SWITCH 4 POLE 4 WAY 06 AMPS 415 VOLTS OF SALZER MAKE OR ANY RDSO APPROVED MAKE. 5

6

751

4506.96

... More
NET SELECTOR SWITCH 6

6

292

1756.86

... More
POWER ON/OFF SWITCH 7

6

292

1756.86

... More
LED INDICATORS 230 VOLTS AC RED YELLOW, BLUE AND GREEN. 8

12

141

1698.12

... More
LED INDICATORS 110 VOLTS DC RED YELLOW, WHITE AND GREEN. 9

12

141

1698.12

... More
LED INDICATORS 24 VOLTS DC RED YELLOW ,WHITE AND GREEN. 10

12

141

1698.12

... More
MONOBLOCK PUMP 0.5 HP 3 PHASE 415 VOLTS, WITH TOP FOR LHB AC COACHES.

6

4878

29273.88

... More
WATER RAISING PUMP CONTROLLER FOR LHB AC COACHES.KIND MAKE OR ANY RDSO APPROVED SIMILAR MAKE.

6

3555

21333.3

... More
MPCB 1.0- 1.6 AMPS FOR PUMPS IN LHB AC COACHES. MODEL MS 116 OF ABB MAKE OR SIMILAR RDSO APPROVED MAKE.

6

2108

12650.46

... More
ELCB FOR HOT WATER BOILER AND DEEP FREEZER. 25 AMPS, 30 mA , SIEMENS OR SIMILAR MAKE. 14

12

3285

39430.56

... More
ANALOG TYPE VOLTMETER 72X 72 mm 0-150 VOLTS DC 15

6

912

5473.5

... More
VOLTAGE SELECTOR SWITCH 16

6

355

2130.66

... More
AMMETER SELECTOR SWITCH

6

355

2130.66

... More
LT HRC FUSE 25 AMPS MODEL NO: NH 000 gG OF SIEMENS MAKE OR ANY SIMILAR RDSO APPROVED MAKE.

12

234

2819.52

... More
LT HRC FUSE 40 AMPS MODEL NO: NH 000 gG OF SIEMENS MAKE OR ANY SIMILAR RDSO APPROVED MAKE.

12

437

5254.56

... More
LT HRC FUSE 80 AMPS MODEL NO: NH 000 gG OF SIEMENS MAKE OR ANY SIMILAR RDSO APPROVED MAKE.

12

532

6386.64

... More
LT HRC FUSE 100 AMPS MODEL NO: NH 000 gG OF SIEMENS MAKE OR ANY SIMILAR RDSO APPROVED MAKE. 21

12

485

5831.28

... More
ELECTRICAL CHIMNEY FOR HOT BUFFET CARS IN LHB COACHES. 230 VOLTS 0.19 KW, 22

3

14223

42671.94

... More
SMOKE DETECTOR UNIT AGNI MAKE OR SIMILAR RDSO APPROVED MAKE.

6

7338

44028.3

... More
SHUNT 0-50 AMPS 0.75 mV. FOR MEASUREMENT OF BATTERY VOLTAGE AND CHARGING VOLTAGE.

6

3176

19058.46

... More
CONTACTOR 4 POLE WITH 415 VOLT COIL, 125 AMPS, WITH ADD ON BLOCK 2NO + 2 NC OF MODEL CA5-22E OF ABB MAKE OR SIMILAR MAKES OF SCHNEIDER, SIEMENS, AND L &T

6

13743

82460.28

... More
CONTACTOR 4 POLE WITH 110 VOLT DC COIL, 6 AMPS, OF MODEL TKC 6- 312 WITH SNUBBER CIRCUIT OF ABB MAKE OR SIMILAR MAKES OF SCHNEIDER, SIEMENS, AND L &T (PUMP CONTACTOR). 26

6

873

5243.88

... More
AC MCBs 4 POLE 16 AMPS TO 63 AMPS 27

10

1663

16634.1

... More
AC MCBs 3 POLE 10 AMPS TO 32 AMPS 28

10

1149

11498.8

... More
AC MCBs 2 POLE 06 AMPS TO 16 AMPS 29

10

885

8855.5

... More
AC MCBs SINGLE POLE 06 AMPS TO 10 AMPS 30

10

378

3782.5

... More
DC MCBs DOUBLE POLE UP TO 400 VOLTS 06 AMPS TO 16 AMPS

12

1244

14930.64

... More
Removing or fixing of 4.5 KW alternator from/on bogie under frame. 2

1

1222

1222.52

... More
Removing or fixing of axle pulley for axle under frame. 3

1

1675

1675.7

... More
Fitment of set of V belts for transom mounted 4.5 KW Alternator 4

1

200

200.7

... More
Removing or fitting of mono block battery sets including terminal connection etc.

1

1472

1472.7

... More
Overhauling & repairing of 4.5 KW brush less alternator consisting of the following 5 activities - Rewinding of 3 phase winding and winding with suitable size copper winding wire as per ISS and accepted practice complete with replacement of terminal plate made out of 12mm thick fabric based bakelite sheet. The coil shall be formed and vacuum impregnated after varnishing and nomex paper shall be added between coil insulation.

1

9795

9795.6

... More
Overhauling & repairing of 4.5 KW brush less alternator consisting of the following activities - Replacement of driving end bearing witk SKFNU-311 C3 and non driving end bearing with SFK 6309

1

2946

2946.6

... More
Overhauling & repairing of 4.5 KW brush less alternator consisting of the following 7 activities - Replacement of alternator shaft and alternator pully complete with all fixing accessories viz nuts, washers, key etc. The shaft shall be machined out of EN 3 grade material and shall be tested for cracks ultrasonically.

1

3434

3434

... More
Overhauling & repairing of 4.5 KW brush less alternator consisting of the following 8 activities - Other minor works, viz, replacement of cast nylon bushes, cleaning and painting of alternator with 2 coats of yellow enameled paint after applying 2 coats of metallic primer greasing and oiling etc.

1

687

687

... More
Repair/ Reconditioning of 4.5 KW alternator, regulator board by carrying out the following works - Replacement of main diodes along with heat shrinks if damaged.

1

787

787.1

... More
Repair/ Reconditioning of 4.5 KW alternator, regulator board by carrying out the following works - Rewinding of field transformer with moulding

1

971

971.2

... More
Repair/ Reconditioning of 4.5 KW alternator, regulator board by carrying out the following works - Replacement of magnetic amplifier with mouldings

1

3132

3132

... More
Repair/ Reconditioning of 4.5 KW alternator, regulator board by carrying out the following works - Replacement of potentiometer for voltage and current control.

-

-

12

... More
Repair/ Reconditioning of 4.5 KW alternator, regulator board by carrying out the following works - Replacement of auxiliary diodes and field diodes with resistance.

1

971

971.2

... More
Repair/ Reconditioning of 4.5 KW alternator, regulator board by carrying out the following works - Replacement of CT along with burden resistance

1

1272

1272.1

... More
Repair/ Reconditioning of 4.5 KW alternator, regulator board by carrying out the following works - Renewal of complete internal wiring

1

301

301

... More
Repair/ Reconditioning of 4.5 KW alternator, regulator board by carrying out the 16 following works - Other minor repairs including replacement of terminal lugs, terminal blocks and painting in inner and outer surface with one coat of red oxide primer and 2 coats of yellow enamelled paint.

1

385

385.9

... More
Repair /Rewinding of 110 V,DC carriage fan by carrying out the following - Rewinding and providing armature coil assembly as per standard practice.

1

887

887.5

... More
Repair /Rewinding of 110 V,DC carriage fan by carrying out the following - Rewinding and providing field coil assembly as per standard practice.

1

585

585.3

... More
Repair /Rewinding of 110 V,DC carriage fan by carrying out the following - Replacement of both bearings by new bearings.

1

301

301

... More
Repair /Rewinding of 110 V,DC carriage fan by carrying out the following - Repairs/Renewal of commutator assembly

1

2930

2930.1

... More
Repair /Rewinding of 110 V,DC carriage fan by carrying out the following - Repairs/renewal of carbon brushes and brush holders complete. 22

1

134

134.52

... More
Repairing of 110V, DC inverters used for tube lights of coaching stock. 23

1

200

200.6

... More
Repairing of refrigerator &Deep Freezer - Replacement of compressor. 24

1

7650

7650.3

... More
Repairing of refrigerator &Deep Freezer - Replacement of over load relay 25

1

727

727

... More
Repairing of refrigerator &Deep Freezer - Replacement of capacitor

1

581

581

... More
Repairing of refrigerator &Deep Freezer - Attending gas leakage, including supply of gas & gas charging. 27

1

3672

3672.3

... More
Repairing of refrigerator &Deep Freezer - Replacement of blower motor 28

1

2264

2264.5

... More
Repairing of refrigerator &Deep Freezer - Replacement of capillary tubes 29

1

757

757.58

... More
Repairing of refrigerator &Deep Freezer - Replacement of thermo- stats

1

597

597.09

... More
Repairing of refrigerator &Deep Freezer - Replacement of power cable 1.5 sq mm,3 core

1

49

49.55

... More
Repairing of refrigerator &Deep Freezer - Shifting, fixing & connecting of refrigerator OR deep freezer 32

1

1530

1530.52

... More
Replacement of socket, switch assembly for laptop/mobile charging points.

1

496

496.79

... More
Fixing & connecting of mobile charging inverter. 34

1

229

229

... More
Removal of defective alternator. 35

1

1960

1960.05

... More
Fitting of new alternator. 36

1

1960

1960.05

... More
Removal of defective regulator. 37

1

100

100.3

... More
Fitting of new regulator. 38

1

100

100.3

... More
Supply and fitting V belt set of C122 12 belts in matched group for alternator. 39

1

8817

8817.31

... More
Supply and fitting V belt set of C122 4 belts in matched group for alternator. 40

1

2939

2939.5

... More
Removal of defective battery cells and fitting of new cells

1

301

301

... More
Providing man power ( semi skilled ) to assist departmental staff for maintenance of RA coach, transportation of heavy materials from store to depot, house keeping depot office etc.(Unil shall be read as Per person per day)

3500

3307500

3307500

... More
Repairing of 60 KV step down transformer including spares. 2

10

49486

494866

... More
Repairing of 9/15 KVA step down transformer for LHB TL coaches including spares.

10

9347

93475

... More
Supply of spare parts to be supplied during AMC as and when required by KRCL. Spares / materials are to be procured from OEMs / RDSO Approved Vendors / manufacturer or 1 authorized dealers. Firm has to submit a copy of Tax invoice / purchase bill during supply of material. Payment shall be made as per Tax invoice plus 10% handling charges. Quantity & unit : No estimate can be given of the quantity or value of spares which may be ordered. However, withdrawal orders shall be placed on actual requirement basis from time to time during currency of contract.

1

1500000

1500000



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.