Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2024_GU_17129_1Tender No
GU/9/2024-2025/Engg and Tech Div/161Tender Authority
Goa University ViewPurchaser Address
-Website
http://eprocure.goa.gov.in
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
BOQ Items
(b) Cat B
35
-
-
Supplying and fixing modular blanking plate on the existing modular plate switch box excluding modular plate etc. as required
-
-
-
(b) Cat B
99
-
-
Supplying and fixing suitable size modular PVC box with modular plate and cover in front on surface or in recess including providing and fixing 1 no 6 pin 15/16 A modular socket outlet and 1 nos 15/ 16 A modular switch connection painting etc. as required. ( For workstations)
-
-
-
(b) Cat B
12
-
-
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FR PVC insulated copper conductor single core cable in the independent PVC casing capping of appropriate size as required.
-
-
-
(b) 2 x 2.5 sq.mm + 1 x 2.5 sq.mm earthwire (20mm casing )
324
-
-
(c) 2 x 4 sq.mm + 1 x 4 sq.mm earthwire (20mm casing )
306
-
-
Supply of 3 1/2 core armoured PVC/XLPE insulated, PVC sheathed aluminium conductor cable of 1.1 KV grade with ISI mark conforming to IS:1554(Part I) ,IS:7098(Part I) with latest amendments of following size.
-
-
-
3 1/2 Core 120 sq.mm
24
-
-
Laying of one number PVC insulated and PVC sheathed/XLPE power cable of 1.1 KV grade of size exceeding 25 sq.mm but not exceeding 120 sq.mm in the existing masonry open duct, etc. complete as required
24
-
-
Supplying and making cable end terminations with brass compression gland and copper lugs for folowing sizes of 3 1/2 Core PVC insulated PVC sheathed/XLPE aluminium conductor cable of 1.1 KV grade, complete as required. (6) 3 1/2 x 120 Sq. mm.
4
-
-
Supply of 4 core armoured PVC/XLPE insulated, PVC sheathed copper conductor cable of 1.1 KV grade with ISI mark conforming to IS:1554(Part I) ,IS:7098(Part I) with latest amendments of following size.
-
-
-
4 Core 10 sq.mm
100
-
-
Laying of one number PVC insulated and PVC sheathed/XLPE power cable of 1.1 KV grade of size not exceeding 25 sq.mm on surface, etc. complete as required
50
-
-
Laying of one number PVC insulated and PVC sheathed/XLPE power cable of 1.1 KV grade of size not exceeding 25 sq.mm in the existing masonry open duct, etc. complete as required
50
-
-
Supplying and making cable end terminations with brass compression gland and copper lugs for folowing sizes of 4 Core PVC insulated PVC sheathed/XLPE aluminium conductor cable of 1.1 KV grade, complete as required.
-
-
-
4 Core 10 sq.mm
12
-
-
Supply installation, testing and commissioning of panel for UPS Single front, floor/wall mounted ,fully compartmentalized, with separate chambers for power, cables and busbars,indoor, all mccbs with rotary handle, Construction: Structural members – 2.5mm , doors – 1.6mm CRCA, covers & partitions – 1.6mm CRCA, base frame –75x75x5mm CRCA, Component Mounting Plates – 2mm CRCA, Gland Plates – 2mm CRCA, Gaskets: Soft EPDM rubber gaskets, completely derusted, chemically treated in 7 tank process Painting/ Powder coating in RAL 7032 Siemens Grey. Degree of Protection – IP52, Applicable Standard: IS:8623-1994, Insulation Volts: 660V, 50-60Hz, System Volts: 415V, 50Hz, 3-phase, 4-wire, Ambient Temperature: 40oC, Relative Humidity: 90%
-
-
-
Incomer 250A Thermal Magnetic 36KA 4P MCCB with rotary handles suitable for 2nos of 31/2CX120 sqmm AYFY with RYB lamp set
-
-
-
400A 4P Busbar
-
-
-
outgoing 5 sets 60A thermal magnetic based 4P 36KA MCCB with rotary handles with outgoings for each 4cx10sqmm YWY cable
-
-
-
UPS Panel as above
1
-
-
Supply installation, testing and commissioning of panel for ups outgoing Single front, floor/wall mounted ,fully compartmentalized, with separate chambers for power, cables and busbars,indoor, all mccbs with rotary handle, Construction: Structural members – 2.5mm , doors – 1.6mm CRCA, covers & partitions – 1.6mm CRCA, base frame –75x75x5mm CRCA, Component Mounting Plates – 2mm CRCA, Gland Plates – 2mm CRCA, Gaskets: Soft EPDM rubber gaskets, completely derusted, chemically treated in 7 tank process Painting/ Powder coating in RAL 7032 Siemens Grey. Degree of Protection – IP52, Applicable Standard: IS:8623-1994, Insulation Volts: 660V, 50-60Hz, System Volts: 415V, 50Hz, 3-phase, 4-wire, Ambient Temperature: 40oC, Relative Humidity: 90%
-
-
-
Incomer 250A Thermal Magnetic 36KA 4P MCCB with rotary handles suitable for 10 nos of 4cx25 sqmm ywy with RYB lamp set
-
-
-
400A 4P Busbar
-
-
-
outgoing 12 sets 60A thermal magnetic based 4P MCCB with rotary handles with outgoings for each 4cx10sqmm YWY cable
-
-
-
UPS outgoing Panel as above
1
-
-
Supplying and fixing 63 A, C series MCB suitable for lighting and other loads of following poles in the existing MCB DB complete with connections testing and commissioning etc as required.
-
-
-
(j) TPN, Cat B
1
-
-
Supplying and laying 25 mm x 5 mm copper strip in 40 mm dia GI pipe from earth electrode as required
40
-
-