Construction Of Unity Mall Goa At Chimbel Panaji Goa A Scheme Under The Special Assistance To The State For Capital Investment By Govt. Of India

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
Felling trees of girth(measured at a height of 1. m. Above ground level) inluding cutting of trunks and branches removing the roots stacking the serviceable material and disposal of unserviceable material for all leads : Beyond 60 cm and upto 120 cm girth

55

-

-

... More
Felling trees of girth(measured at a height of 1. m. Above ground level) inluding cutting of trunks and branches removing the roots stacking the serviceable material and disposal of unserviceable material for all leads : Beyond 120 cm and upto 240 cm girth

30

-

-

... More
Earth work in excavation over areas of all type of strata comprising of any type of material such as soil ,silt,clay, sand, saturated soil, gravel, murum of all varieties, shingles, pebbles, all type of congolmerates,latrite rock,soft rock,ordinary rock, disintegrated rock,fissured/shattered rock, decomposed rock, weathered rock and all such material either in full or part as the case may be adopting any method/ methods as may be convenient or permitted (blasting prohibited) including chiselling ,wedging,etc., in all conditions such as dry , moist, foul, saturated, submerged, etc., as directed by the Engineer etc., all complete including dressing of side ramming bottom, all leads and lifts, getting out excavated soil & stacking as directed , pumping and bailing out water, barricading,danger lighting, guarding as directed.(At all depth)

24618.19

-

-

... More
Earthwork in excavation in trenches for all leads & lifts in all type of strata comprising of any type of materials either in full or part as the case may be adopting any method/methods as may be convenient as permitted excluding blasting in all conditions such as dry, moist, foul, saturated, submerged, etc,. including dressing of sides, planking & strutting, timbering ,ramming of bottom ,pumping and bailing out water ,barricading danger lighting guarding, getting out excavated soil & stacking as directed by Engineer for all leads & lifts etc. complete

1890

-

-

... More
Refilling the pipeline/foundation trenches plinth sides, foundation etc. with available excavated earth in layers not exceeding 20 cm depth consolidating each layer ramming and watering lead upto 50 M and all lifts and disposal of surplus earth as directed by Engineer .

1512

-

-

... More
Supplying and filling Moorum in plinth under floors, trenches including watering ramming consolidating, dressing, complete.

40600

-

-

... More
Providing and laying autoclaved aerated cement blocks masonry with 100mm/150mm/200mm AAC blocks in substructure & superstructure up to floor V level in cement mortar 1:4 (1 cement : 4 coarse sand). The rate includes providing and placing in position 2 Nos 6 mm dia M.S. bars at every third course of masonry work.

3398.58

-

-

... More
Laterite masonry of dressed stones of size as specified laid dry in pitching riverment etc.

338.33

-

-

... More
Rubble packing with hard laterite stone under floors including watering ramming and consolidating etc. in pipeline trenches and other foundations complete.

4800.3

-

-

... More
Laterite masonry in neatly dressed stones of size as specified in cement mortar 1:4 (1 cement : 4 coarse sand) in foundation and superstructure

599.44

-

-

... More
Providing & laying damp proof coarse 25 mm thick with cement concrete with 1: 2:4 (1 cement: 2coarse sand: 4 graded granitic or basaltic stone aggrt. 10 mm. nominal size)

505.34

-

-

... More
Providing & laying cement concrete 1:2:4 (1 cement: 2 coarse sand: 4 graded granitic or basaltic stone aggregate 20 mm. nominal size) excluding cost of centering, shuttering and finishing in: All work up to Plinth level

2462.42

-

-

... More
Providing and laying up to floor 5 level cement concrete 1 : 2 : 4 ( 1 Cement : 2 coarse sand : 4 graded granitic or basaltic stone aggregate 20 mm nominal size) including smooth finishing to exposed surfaces ,cement mortar 1:3 ( 1 cement : 3 fine sand ) including centering and shuttering etc. for string courses ,coping ,bed plate,anchor block,plain window sills and the like.

25

-

-

... More
Providing and laying plum concrete in cement concrete 1:2: 4 (1 cement: 2 coarse sand: 4 graded granitic or basaltic stone aggregate 40 mm nominal size) with plums not exceeding 15% of the volumne of the finished concrete of size ranging from 150 to 300 mm (but the maximum dimension not exceeding 1/3rd (one third) the least dimension of member under consideration excluding the cost of centering and shuttering:With granitic or basaltic stone plums in :foundation and plinth

1082.52

-

-

... More
Providing and laying in position machine batched concrete (BMC)/Ready mixed concrete ( RMC) , machine mixed and machine vibrated design mix cement concrete of specified grade for reinforced cement concrete work including pumping of concrete to the site of laying but excluding the cost of centering , shuttering, finishing and reinforcement including admixtures in recommended proportions as per IS 9103 to accelerate, retard setting of concrete, improve workability without impairing the strength and durability as per the direction of the Engineer-in-charge. All works upto floor V level. M-30grade of concrete

11218.44

-

-

... More
Providing and laying in position machine batched concrete (BMC)/Ready mixed concrete ( RMC) , machine mixed and machine vibrated design mix cement concrete of specified grade for reinforced cement concrete work including pumping of concrete to the site of laying but excluding the cost of centering , shuttering, finishing and reinforcement including admixtures in recommended proportions as per IS 9103 to accelerate, retard setting of concrete, improve workability without impairing the strength and durability as per the direction of the Engineer-in-charge. All works upto floor V level. M-20grade of concrete

2855.32

-

-

... More
Centering and shuttering including strutting, propping, & removal of form for Foundation, footings, bases of columns

3965.56

-

-

... More
Centering and shuttering including strutting, propping, & removal of form for Vertical surfaces such as retaining walls, return walls, Partitions, walls (any thickness) including attached Pilasters, Buttresses, Plinth and string courses, Fillets and the like

5796.58

-

-

... More
Centering and shuttering including strutting, propping, & removal of form for Columns, Piers, Pillars, Abutments, Posts and struts (square rectangle polygon in plan)

9305.16

-

-

... More
Centering and shuttering including strutting, propping, & removal of form for Sides and Soffits of beams, Beam Haunchings, Cantilever, Girders, Bressumers and Lintels plinth beams not exceeding 1m in depth

5937.95

-

-

... More
Centering and shuttering including strutting, propping, & removal of form for Staircases (except spiral staircases) excluding landing .

453.6

-

-

... More
Centering and shuttering including strutting, propping, & removal of form for Suspended floors, roofs, landings, shelves & their supports

11875.89

-

-

... More
Providing corrosion resistant steel CRS-50 bars of (SAIL, TATA, VIZAG, JSW Steel Ltd.)(Confirming to IS 1786 if 1985) for RCC work including bending, binding & placing in position in all the floors along with factory made precaste concrete cover blocks of specified s izes whose compressive strengthis not less than that of surrounding concrete in the structural member .

1414699

-

-

... More
Extra to be added for additional height in centering, shuttering where ever required with adequate bracing, propping etc. including cost of de- shuttering and de-centering at all levels, over a height of 3.5m, for every additional height of 1m or part thereof. (Plan area to be measured) Suspended floors, roofs, landings, beams and balconies (plan area to be measured)

13786.3

-

-

... More
Providing, supply & Fixing 2hrs. fire rated door Systems duly tested for Integrity & Insulation as per IS : 3614 part 2 & BS:476 part 20 & 22 to achieve the required integrity & insulation with hardwood frame (as per manufacturer's specification) with non-combustible heat resistance and asbestos free insulating material infill shutter of 56mm thk, faced with 4 mm thk waterproof ply & 1 mm thk laminate on both sides to form fully flushed shell frame complete with hardware preparations, prepunctured at factory including EPDM smoke seal , Panic Latch , stainless steel ball bearing hinges,2 hrs fire rated door closer & Vision Panel all complete as shown in drawings

46.08

-

-

... More
Supply and installation of Aluminium Louvers ventilator. The frame should be made of Aluminium tubes of size 100x50X1.50 mm thk and 50X25x1.50 mm thk C channels. Aluminium Z shaped louvers of 100mm should be fixed to the supporting frame with aluminium cleats, GI screws, etc complete. The whole assembly is powder coated with pure polyester paint. (MS framing to be paid separately).

9

-

-

... More
Steel work welded ( SAIL , TATA , VIZAG & using electrodes of AdOr make only ) in built up sections trusses and framed work including cutting, hoisting, fixing in position and applying one coat of primer of red lead paint before erection & one coat after erection. In Tees, Angles, flats and channels

1157.33

-

-

... More
Providing & fixing M.S. Rivets of sizes in position.

17.58

-

-

... More
Supplying and fixing rolling shutters of approved make, made of 80 x 1.25 mm M.S. laths interlocked together through their entire length and jointed together at the end by end locks mounted on specially designed pipe shaft with brackets, side guides and arrangements for inside and outside locking with push and pull operation complete including the cost of providing and fixing necessary 27.5cm long wire springs grade No.2 and M.S. top cover of 1.25mm thick for folling shutterstop cover and spring.

120

-

-

... More
Providing and fixing pre-fabricated Double leaf compound gate with outer frame 120 X60 mm Box section with 16mm bright square bars scroll of 16 X 8 mm flat with aldrop tower – built , cover plate and bearing including providing 450 mm height 300 mm width motifs of M S plate 4 mm thick and locking arrangement, pintals and hold fast embedded in cement concrete 1:2:4 (1 cement: 2 coarse sand : 4 granitic or basaltic aggregate 20mm nominal size) including applying priming coat with ready mixed red lead paint and painting 2 or more coats with superior ready mixed paint of approved brand and manufacture in all shades as per direction of Engineer including transportation and loading , unloading charges etc complete.

9900

-

-

... More
Providing and fixing stainless steel (Grade 304) railing made of Hollow tubes, channels, plates etc.with hairline finish, including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners, stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer, ( for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.).

500

-

-

... More
Providing and fixing M.S. plain grill of required pattern in Windows etc. with M.S. flats square or round bars with round headed bolts and nuts or by by screws with applying a priming coat of approved steel primer .

1000

-

-

... More
Providing and fixing of S.S. AISI 316 grade Railing of 1.05m high with glass panelling of 10mm toughened glass of approved make & approved colour fitting with S.S. glass studs with verticals of 38 X 38 mm S.S. pipe (16 guage - 1.25mm thk) at spacing of 1200mm c/c with fixing in Granite with core cutting & Chemical Grouting with top handrail of 50 mm dia S.S. pipe (16 guage - 1.25mm thk) as per detailed design and drawing or as directed by Engineer. including all materials, labour and equipment etc. complete.

349.67

-

-

... More
Providing and and laying vitrified floor tiles in different sizes of Johnson, Somany, Kajaria (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS:15622 of approved make in colours and shades as specified laid on 20 mm thick cement mortar 1:4 (1 Cement : 4 Coarse sand) including grouting the joints with white cement and matching pigment etc., complete

4658.87

-

-

... More
Providing and and laying scratch resistant floor tiles in different sizes of Johnson, Somany, Kajaria (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS:15622 of approved make in colours and shades as specified laid on 20 mm thick cement mortar 1:4 (1 Cement : 4 Coarse sand) including grouting the joints with white cement and matching pigment etc., complete

123.44

-

-

... More
Providing and fixing 1st quality ceramic glazed wall tiles with Wall Ceramic Glazed Tiles : 300 x 600 (Johnson, Somany, Kajaria )conforming to IS:15622 (thickness to be specified by the manufacture of approved make in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in-charge in skirting, risers of steps and dados over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand ) and jointing with grey cement slurry @3.3kg per sq.m including pointing in white cement mixed with pigment of matching shade complete.

1294.91

-

-

... More
Providing and fixing Vinyl flooring of approved shade and design with adhesive complete.

96.56

-

-

... More
Providing red agra stone flooring 30 mm thickness (avg) on 20 mm thick base of cement mortar 1:4 (1 cement :4 coarse send) jointed with grey cement slurry mixed with pigment to match the shade of the tile including rubbing and polishing complete

40.03

-

-

... More
Providing and laying approved flamed finish Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing, curing and polishing etc. all complete as specified and as directed by the Engineer.

6967.47

-

-

... More
Providing and fixing Granite stone slabs (flamed finish) 18mm thick in risers of steps, skirting, dado and pillars laid on cement paste and jointed with grey cement slurry mixed with pigment to match the shade of the slabs, including rubbing and polishing complete

279.93

-

-

... More
Providing and fixing Approved Colour Polished Granite stone slabs (mirror polished) 18mm thick in risers of steps, skirting, dado and pillars laid on cement paste and jointed with grey cement slurry mixed with pigment to match the shade of the slabs, including rubbing and polishing complete.

399.88

-

-

... More
Providing and and laying vitrified unglazed porcelain tactile floor tiles in different sizes of Johnson, Somany, Kajaria (thickness to be specified by the manufacturer) and conforming to IS:15622 of approved make in colours and shades as specified laid on 20 mm thick cement mortar 1:4 (1 Cement : 4 Coarse sand) including grouting the joints with white cement and matching pigment etc., complete 300 x 300 mm Design - Liner

378

-

-

... More
Providing and and laying vitrified unglazed porcelain tactile floor tiles in different sizes of Johnson, Somany, Kajaria (thickness to be specified by the manufacturer) and conforming to IS:15622 of approved make in colours and shades as specified laid on 20 mm thick cement mortar 1:4 (1 Cement : 4 Coarse sand) including grouting the joints with white cement and matching pigment etc., complete 300 x 300 mm Design - Buttons

94.5

-

-

... More
Providing and fixing 18 mm thick Granite of any colour and shade, gang saw cut, mirror polished, premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills, facias, door frames and similar locations of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 (1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing, moulding and polishing to edges to give high gloss finish etc. complete at all levels. area of slab over 0.50 sqm

40.89

-

-

... More
Providing 25mm thick cuddapah slabs machine cut and polished on either side in partitions including making necessary grooves in the wall and fixing with cement mortar, complete as directed by the engineer.

81.79

-

-

... More
Extra for providing opening of required size & shape for wash basins / kitchen sink in kitchen platform, vanity counters and similar location in marble / granite / stone work including necessary holes for pillar tap etc. including rubbing and polishing of cut edges etc. complete.

10

-

-

... More
Providing and fixing in position Glass mossaic tiles at finished plain/flat/curved/inclided surface of size 10-50 mm square x 4 mm in all colour, design , fixing in customize design as per direction of Engineer. The glass mosaic tiles to be fixed on the surface with the help of approved adhesive applied at the rate of 2.5 kg per sqm and grouting of the same. The rate is inclusive of all operation, material and required pattern approved by Engineer.

1129.15

-

-

... More
Providing leather finished polishing to Granite Stones labby continuous grinding in 4 coats of different bits to receive rough and matt finish including buffing processbe for laying and fixing of stone as per drawing and design, including cleaning, washing and finishing etc. complete.

1045.12

-

-

... More
Providing and laying integral cement based treatment (Box type) for water proofing on the vertical surface by fixing specified stone slab 20 mm to 25 mm thick with cement slurry mixed with water proofing compound conforming to IS:2645 in recommended proportions with a gap of 20 mm (minimum) between stone slabs and the receiving surfaces and filling the gaps with neat cement slurry mixed with water proofing compound and finishing the exterior of stone slab with cement mortar 1:3 (1 cement : 3 coarse sand) 20 mm thick with neat cement punning mixed with water proofing compound in recommended proportion complete at all levels and as directed by Engineer using rough Shahbad/Kotah stone.

1009.13

-

-

... More
Providing and fixing waterproofing treatment to sanitary blocks consisting of layers of Laterite stone coba of 75 mm thick in cement mortar 1:2 sand witched between two layers of cement mortar 1:4 (20 mm thick ) mixed with water proofing compound, top finishing coat of cement slurry 6 to 12 mm thick with water proofing compound etc. complete with 32 mm dia PVC pressure relief pipe of adequate length including waterproofing treatment to 750 mm height (maximum) of side wall, and bottom surface in cement mortar 1:4 with waterproofing compound and covering 10 years guarantee on court fee stamp of Rs. 100 with ponding test including all lead, lift etc. complete as directed by Engineer.

844.88

-

-

... More
Providing water proofing treatment over the new R.C.C. roofs terrace toilet by spreading cement slurry over the R.C.C. slab and laying of 10cms. Average laterite stone ballast coba with the necessary gradient for easy flow of rain water and the coba in covered with damp proof of Hindustan water proofing co. Or equivalent jointless water proofing plaster of mix 1:3 ( 1 cement : 3 find sand), finished smooth with wooden trowel with false marking of 30 cms square. The vertical surface of the adjoining walls are to be treated upto a height of 30cms including rounding of junction (the rate includes for complete items including labour and materials and including cost of initial treatment of roof slab as follows. The injunction of damp proof or equivalent compound with cement solution will be given as and when found necessary for filling honey comb, cracks etc. in the R.C.C. slabs). NOTE: cement consumption 25 kg/sq.m.

1586

-

-

... More
Providing and fixing in position Gypsum board false ceiling with 12.5 mm thick Gypsum boards, screwed/fixed to the under structure of suspended G.I. Grid constructed and suspended from the main ceiling consisting of ceiling sections of size 25 x 50 mm maximum center to center distance of 600 milimetre perimeter channel and intermediate channels at maximum center to center distance 1200 milimetre galvanized grid should be fixed to reinforced cement concrete slab. The gypsum board should be fixed to galvanized iron grid with necessary screws. The boards should be taped and filled from underside to give smooth, seamless ceiling. The rate should include necessary additional ceiling sections and intermediate channels. Additional intermediate channels should be fixed to strap hangers for additional support to prevent strapping at every 1200 milimetre item to be completed in all respect including necessary sleeves for ducts finishing of joints cut outs, painting including labour, material, lifts etc. all complete.

10477.18

-

-

... More
12 mm thick cement plaster 1:4 (1 cement:4 fine sand)

27698.7

-

-

... More
6mm thick cement plaster with 1:3 (1 cement : 3 fine sand)

150

-

-

... More
Providing and applying white cement based putty of average thickness 1.00mm of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete.

38175.87

-

-

... More
18mm cement plaster in two coats under layer 12mm thick cement plaster 1:5 ( 1 cement : 5 coarse sand) and top layer 6mm thick with cement plaster 1: 3 (1 cement : 3 coarse sand) finished with sponge.

108.71

-

-

... More
Extra for plastering exterior walls of height more than 10m from ground level for every additional height of 3m or part thereof.

3463.39

-

-

... More
Extra for providing and mixing water proofing material proportion recommended by the manufacturers. (a)12mm cement plaster 1: 3 (1 cement : 3 sand)

4958.65

-

-

... More
Providing and filling joints between concrete and masonry wherever specified in cement mortar including raking the joints to form "V" groove, applying neat cement slurry, filling with aggregate of 20 mm or less (Katka) in cement mortar 1:4 (1 cement : 4 fine sand), cleaning and curing etc. to avoid cracks at the joints.

2252

-

-

... More
Providing and fixing GI hexagonal chicken wire mesh 22 gauge size of 20cm wide at the junction of dissimilar surface of brick / block masonry wall and RCC column/ beam and the like including necessary "U" nails for fixing , overlapping etc. complete as per specification and as directed by Engineer for all floors and at all height.

1190.4

-

-

... More
Painting (two or more coats) with synthetic enamel paint of approved brand and manufacture in all shade or new work over and under coat of suitable shade with ordinary paint of approved brand and manufacture to give an even shade

27698.7

-

-

... More
Painting three or more coats with acryllic exterior paint of approved brand and manufacture (such as weather shield,APEX) including applying one coat of cement primer and one coat of surface treatment etc. complete.

250

-

-

... More
Wall painting (two or more coats) with plastic emulsion paint of approved brand and manufacture on new work to give an even shade.

250

-

-

... More
White washing with lime on new work ( three or more coats) to give an even shade.

15715.76

-

-

... More
Providing and applying Texture plaster with finishing with texture material of approved make in 3 to 4 millimeter thickness on previously plastered surface, including Plaster Groove 6mm thickness or Tape Grooves 35 to 45 mm thickness or as required, in all position including preparing the surface, scaffolding, Painting etc. complete

8309.61

-

-

... More
Extra for painting on walls on the outside at height more than 10m from ground level for every additional height of 3.0 m or part thereof.

8309.61

-

-

... More
Vaccum dewatering of laid concrete for roads/ areas using Tremix machinery including formwork with MS channel/ angle sections on sides of concrete with proper supporting system, surface/screed & needle vibrating & levelling of concrete. Vaccum dewatering should be done using suction mats (spread on surface) & suction pump, power floating/ troweling using screen floater, manual spreading of hardening compound (if any), smooth/rough/broom finish to the required slope, camber & level, groove cutting (upto 10mm wide x50mm deep) for contraction/expansion, construction & longitudinal joints, Providing dowel bars with sleeve/tie bars, filling two component polysuphide sealant/joint filler (Bitumen hot sealing compound: Grade A), taping with masking tape etc complete. (Concrete, reinforcement, Dowel Bar with sleeve/tie bar Reinforcement, tarpaulin sheet to be paid separately)

1549.25

-

-

... More
Providing & Fixing Flat Type Rubberized speed breaker of 400 mm wide & 50 mm height for general traffic at preferred crossing speed of 25 km/h and above as per standard having and specification in IRC in Black / yellow colour . The rubberized speed breaker shall be fixed with all required nails, anchor fastners, accessories all etc. complete.

60

-

-

... More
Providing and laying factory made Shot blasted cement concrete interlocking paver block of minimum M35 grade made by heavy duty block making machine with strong vibratory compaction and of aprpoved size and design / shape laid in 50 mm thick compacted bed of coarse sand, filling the joints with coarse sand, etc. all complete as per the direction of Engineer.- in I, Wave, Rectangular, Square etc. shapes. The products should comply to IS 15658:2006 and manfucatured by ISO9001: 2008 certified plant. The shot blasting should be done using 0.4-0.5mm dia steel shots with a speed of 3200 rpm. 60 mm thick in all colours except grey (M35 grade)

5150

-

-

... More
Providing and laying factory made Shot blasted cement concrete interlocking paver block of minimum M35 grade made by heavy duty block making machine with strong vibratory compaction and of aprpoved size and design / shape laid in 50 mm thick compacted bed of coarse sand, filling the joints with coarse sand, etc. all complete as per the direction of Engineer.- in I, Wave, Rectangular, Square etc. shapes. The products should comply to IS 15658:2006 and manfucatured by ISO9001: 2008 certified plant. The shot blasting should be done using 0.4-0.5mm dia steel shots with a speed of 3200 rpm. 80 mm thick in all colours except grey (M40 grade)

6500

-

-

... More
Supplying and fixing Pre-cast cement concrete kerb-stones(factory made,the factory should be ISO certified and registered under Dirctorate of Industries, Govt. of India) of M-20 with 20 mm nominal size granitic/basaltic aggregate properly consolidated by mechanical plat-form and vibrators with smooth finish including fixing at site complete as per specification. Size 60 cm L x45 cm H x 15 cm T

1500

-

-

... More
Providing and laying of hot applied thermoplastic compound 2.5 mm thick including Reflectorising glass beads @ 250 gms per sqm area, thickness of 2.5 mm is exclusive of surface applied glass beads as per IRC 35. The finished surface to be level uniform and free from streaks and holes as per MoRT & H Specification 803

189

-

-

... More
Design, supply & installation of suspended Spider Glazing system (Frameless glass structural glazing) designed to withstand the wind pressure as pr IS 875 (Part-III). The Suspended System held with Spider Fittings of SS-316 Grade Steel of approved manufacturer with glass panel having 12 mm thick clear toughened glass held together with SS- 316 Grade Stainless steel Spider & bolt assembly with laminated glass fins 21mm thick. The Glass fins and glass panel assembly shall be connected to Slab/beams by means of SS- 316 Grade stainless steel brackets & Anchor bolts and at the bottom using SS channel of 50x25x2mm using fastener & anchor bolts, non staining weather sealants of approved make, Teflon/ nylon bushes and separators to prevent bi-metallic contacts, all complete to perform as per specification and approved drawings. The complete system to be designed to accommodate thermal expansion & seismic movements etc. The joints between glass panels (6 to 8 mm) and gaps at the perimeter & in U channel of the assembly to be filled with non staining weather sealant, so as to make the entire system fully water proof & dust proof. The rate shall include all design, Engineering and shop drawing including approval from structural designer, labour, T&P, scaffolding , other incidental charges including wastage, enabling temporary services all fitting fixers nut bolts, washer, Buffer plates, fastener, anchors, SS channel laminated glass etc. all complete. For the purpose of payment, actual elevation area of Glazing including thickness of joints and the portion of Glass panel inside the SS channel shall be measured.

3666.45

-

-

... More
Design, fabricate, package, deliver (to Job site) and install curtain wall systems comprising specified glass. The glass panels will be mechanically supported to the aluminium main frame with pressure plate & cover cap on outer surface and fixed onto mullions and transoms including functional design of the aluminum sections for fixing glazing panels of various thicknesses, aluminium cleats, sleeves and splice plates etc. gaskets, screws, toggles, nuts, bolts, clamps etc., structural and weather silicone sealants, flashings, fire stop (barrier)-cum-smoke seals, microwave cured EPDM gaskets for water tightness,pressure equalisation & drainage and protection against fire hazard with all approved standard accessories and hardware’s of approved make. All aluminium extruded profiles shall be confirming to alloy 6063 T6. All Aluminium profiles shall be with pure ployster powder of thickness 75-80 microns and shade shall be as per architect's approval. The curtain wall shall be sealed to the host structure and not adjoining materials with approved water proofing membrane and insulation to prevent sound transmission. The System and glass shall be designed to withstand 1.5 times the design wind pressure at all levels, elevation & heights. The anchoring / bracing of the curtain wall system to the RCC slab / beams / columns shall be done with non-corrosive galvanized brackets of approved design (80-90 micron thickness) and including providing teflon shims of various thickness to adjust the beam level / line variations fixed with SS dash fasteners Hilti , Fisher or equivalent of min. 12mm dia. and depth of 50-80mm in the concrete and to withstand the dead load of the curtain walls as well as stresses due to wind pressure etc. Expansion joint gap for mullion shall be minimum 15 to 20mm filled with expansion joint sealant from Dow Corning of DC 790 . All screws, washers used shall be only stainless steel of 304 grade and Through Bolts , Nuts & anchors used shall be only stainless steel of 316 grade.The contractor must design the system as per the prevalent site conditions and building elevation profiles. No extra claims shall be entertained at any stage for aluminium profile wall thickness and size dimensions. Material supporting arrangements shown in the drawing are indicative and contractor shall make their own shop drawings and suggest method of fixing with type of anchors they propose to use where they are to be fixed. including providing and supplying at site additional frame with all accessories and hardwares for the openable panels as specified and of the approved make such as heavy duty stainless steel friction hinges, min 4 -point cremone locking sets with stainless steel plates, handles, buffers etc. including necessary stainless steel screws/ fasteners, nuts, bolts, washers etc. all complete as per the Architectural drawings, as per the approved shop drawings, as specified and as directed by the Engineerin- Charge. Work to include required double legged independent scaffolding for entire height or as required to approval of the PM. with Double Glass Unit ( DGU - with U Value less than 2.69) of approved make & approved colour with 6 mm clear glass for inner lite ( Heat Strengthened ), 12mm air gap & 6mm approved colour glass for outer lite ( Heat Strengthened )

2326.6

-

-

... More
Providing & fixing in position Frame less sensor operated glass double shutter sliding doors with 12 mm thick toughened crystal edge polished glass with approved etching design manufactured to relevant I.S. codes from approved manufacturer including cost of activators, switches, track and mounting profile, Carrier, Door suspension device with adjustable fixture, Motor with decoder,Track rail, Return pulley, Basic module, control with integrated switched power supply unit and multi-way connectors for optional expansion modules, Door stop, safety sensors etc.Dorma Make or equivalent as required all complete at all heights as per approved drawing and as directed by the Engineer-in-Charge. All exposed edges of the glass shall be ground, polished and rounded. The door shall be provided with sensing devices to detect motion in front of the door( Both Inner and Outer face ), activate the control mechanism and thus open and close the door.

39

-

-

... More
Providing and Fixing Processed laterite Stone Cladding on wall surface/ plywood surface. RCC pardi/ Wall and all type of Interior, Exterior Compound wall and Gate etc. of cladding processed stone with material of Processed clay, Wooden chips, Silica sand, Cement, GFRC admixtures, Colour pigments, Fiber up to thick of 230 mm/ 25 mm including scaffolding, fixing of screw, etc. (As directed by Engineer in Charge)

6656.42

-

-

... More
Applying breathable, non-reactive, antifungal, and water repellant Silane/ Siloxane chemical as approved by Archaeological Survey of India/ Engineer, of approved brand and manufacture, diluted with solvent mineral Turpentine oil in the ratio of 1:12 (One part of approved chemical :12 Part of Turpentine oil), on the exposed laterite masonry surface with two or more coats to give uniform application of chemical on the surface, all complete as per direction of Engineer. (The rate is inclusive of all materials & labours).

6656.42

-

-

... More
Providing & Fixing (at all levels) Glass Fiber Reinforced Polymer (GFRP) Decorative Color screen having required thick finished with poly coated oxide colour pigment in three coats with 450 Emulsion in 2 layers including necessary scafolding, anchoring/bolting and necessary civil/fabrication work as per Standard specifications, approved design by Archtect and as directed by Engineer‐in‐charge.

5296.08

-

-

... More
Extra over design, supply and installation of Spider glazing system, for provision of 12mm thk clear toughened glass door shutter fittings including the cost of top & bottom patch fitting, over panel patch, panel connector pivot, over panel/sidepanel connector with pivot, bottom lock, stainless steel hardware fittings of 316 grade for operating door i.e. door handle 450mm Lg, floor spring of approved make and locking arrangement etc. complete including the cost of cutting the floor and making good the same, as per design and drawing all complete as required.

745.09

-

-

... More
Providing anti-termite treatment to the buildings conforming to I.S.S.6113 part II 1971 (revised) including adopting the precautions for health hazards and safety measures as required therein with the cost of all materials, chemicals, plants, equipments required for the treatment and furnishing a guaranty for a minimum period of 10 years from the date of completion including eradicating any infestation of termite free of cost during the guaranty period complete. The payment will be made on plinth of the building (a) preconstruction.

20125

-

-

... More
Making plinth protection 50mm thick of Cement Concrete 1:3:6 (1cement : 6 graded stone aggregate 20mm nominal size) over 75mm bed of dry laterite aggregate 40mm nominal size well rammed and consolidated and grouted with fine sand including finishing the top smooth.

1300

-

-

... More
Drilling 150 mm deep hole in R C C and grouting the rebar, lockfix etc complete. 10 mm Dia

87

-

-

... More
Drilling 150 mm deep hole in R C C and grouting the rebar, lockfix etc complete. 12 mm Dia

85

-

-

... More
Drilling 150 mm deep hole in R C C and grouting the rebar, lockfix etc complete. 16 mm Dia

62

-

-

... More
Providing & fixing expansion joint between structural members by fixing 50 mm thick TF quality thermacol sheet on one surface to serve as shuttering as directed by engineer.

642.98

-

-

... More
Providing and fixing of expansion joint system of approved make and manufactures for various roof locations as per approved drawings and direction of Engineer- In-Charge. The joints shall be of extruded aluminum base members with, self aligning and self centering arragement support plates as per ASTM B221-02. The system shall be such that it provides watertight roof to roof/roof to corner joint cover expansion control system that is capable of accommodating multidirectional seismic movement without stress to its components. System shall consist of metal profile that incorporates a universal aluminum base member designed to accommodate various project conditions and roof treatments. The cover plate shall be designed of width and thickness required to satisfy movement and loading requirements and secured to base members by utilizing manufacturer's pre-engineered self-centering arrangement that freely rotates / moves in all directions. The Self centering arrangement shall exhibit circular sphere ends that lock and slide inside the corresponding aluminum extrusion cavity to allow freedom of movement and flexure in all directions including vertical displacement. The Joint System shall resists damage or deterioration from the impact of falling ice, exposure to UV, airborne contaminants and occasional foot traffic from maintenance personnel. Provision of Moisture Barrier Membrane in the Joint System to have water tight joint is mandatory requirement. Material shall confirm to ASTM 6063. Roof Joint of 75 mm gap

360

-

-

... More
Providing and fixing of expansion joint system related with wall joint (internal/ external) location as per drawings and direction of Engineer-In-Charge. The joints shall be of extruded aluminum base members, self aligning / centering arrangement and support plates as per ASTM B221-02. The material shall be such that it provides an Expansion Joints System suitable for vertical wall to wall/ wall to corner application, both new and existing construction in office Buildings & complexes with no slipping down tendency amongst the components of the Joint System. The Joint System shall utilize light weight aluminum profiles exhibiting minimal exposed aluminum surfaces mechanically snap locking the multi-cellular to facilitate movement. (Material shall confirm to ASTM 6063.) Wall Joint of 75mm gap

83

-

-

... More
Providing and fixing weepholes with rigid PVC make laid in position with a required slope and level while layingpipes of approved the concrete of retaining wall,wing wall and earth retainig structure complete as directed by the Engineer in charge 110 mm dia

385

-

-

... More
Providing and fixing weepholes with rigid PVC make laid in position with a required slope and level while layingpipes of approved the concrete of retaining wall,wing wall and earth retainig structure complete as directed by the Engineer in charge 75 mm dia

395

-

-

... More
Supplying and stacking of good earth ( Garden Soil) at site including royalty and carriage upto 1 km. (earth measured in stacks will be reduced by 20% for payment).

4243.97

-

-

... More
Spreading of sludge, dung manure or/and good earth (Garden Soil) in required thickness (cost of sludge, dung manure or/and good earth to be paid separately).

6129.18

-

-

... More
Supply at site of work/store deoiled Neem cake duly packed in used gunny bags as per MoRT & H Specification 308.2

11.86

-

-

... More
Supplying of sludge duly stacked at site/store as per MoRT & H Specification 308.2

1885.21

-

-

... More
Providing and fixing M.S. flat iron tree guard 60cm dia & 2 m high above ground level, formed of 4 nos. 25 x 6mm and 8 nos. 25 x 3mm vertical M.S. flat iron rings in two halves, bolted together with 8mm dia and 30 mm long bolts including painting two coats with paint of approved brand and manufacture over a coat of priming, complete in all respects.

50

-

-

... More
Filling mixture of earth & sludge or manure in the desired proportion in trenches flooding with water and leveling (cost of supplying earth and sludge or manure and mixing excluded).

1786.05

-

-

... More
Providing, laying and planting various Trees & Palms as listed below as per the mentioned size including adding fertilizers as per planting schedule, manure and Neem cake etc. including their maintainance upto 3 months during which the contractor is suppose to maintain all these in all respects such as watering, pruning, spraying of pesticides, fungicides, insecticides, adding fertilisers, removing of weeds as per specification and direction of the Engineer and also replacing with similar plants in case of death of any plants. The plant will be selected and approved by the Engineer before plantation. Artocarpus heterophyllus

12

-

-

... More
Providing, laying and planting various Trees & Palms as listed below as per the mentioned size including adding fertilizers as per planting schedule, manure and Neem cake etc. including their maintainance upto 3 months during which the contractor is suppose to maintain all these in all respects such as watering, pruning, spraying of pesticides, fungicides, insecticides, adding fertilisers, removing of weeds as per specification and direction of the Engineer and also replacing with similar plants in case of death of any plants. The plant will be selected and approved by the Engineer before plantation. Anthocephalus cadamba

9

-

-

... More
Providing, laying and planting various Trees & Palms as listed below as per the mentioned size including adding fertilizers as per planting schedule, manure and Neem cake etc. including their maintainance upto 3 months during which the contractor is suppose to maintain all these in all respects such as watering, pruning, spraying of pesticides, fungicides, insecticides, adding fertilisers, removing of weeds as per specification and direction of the Engineer and also replacing with similar plants in case of death of any plants. The plant will be selected and approved by the Engineer before plantation. Lagerstroemia speciosa

9

-

-

... More
Providing, laying and planting various Trees & Palms as listed below as per the mentioned size including adding fertilizers as per planting schedule, manure and Neem cake etc. including their maintainance upto 3 months during which the contractor is suppose to maintain all these in all respects such as watering, pruning, spraying of pesticides, fungicides, insecticides, adding fertilisers, removing of weeds as per specification and direction of the Engineer and also replacing with similar plants in case of death of any plants. The plant will be selected and approved by the Engineer before plantation. Bauhinea purpurea

5

-

-

... More
Providing, laying and planting various Trees & Palms as listed below as per the mentioned size including adding fertilizers as per planting schedule, manure and Neem cake etc. including their maintainance upto 3 months during which the contractor is suppose to maintain all these in all respects such as watering, pruning, spraying of pesticides, fungicides, insecticides, adding fertilisers, removing of weeds as per specification and direction of the Engineer and also replacing with similar plants in case of death of any plants. The plant will be selected and approved by the Engineer before plantation. Bauhinea venigeta alba

8

-

-

... More
Providing, laying and planting various Trees & Palms as listed below as per the mentioned size including adding fertilizers as per planting schedule, manure and Neem cake etc. including their maintainance upto 3 months during which the contractor is suppose to maintain all these in all respects such as watering, pruning, spraying of pesticides, fungicides, insecticides, adding fertilisers, removing of weeds as per specification and direction of the Engineer and also replacing with similar plants in case of death of any plants. The plant will be selected and approved by the Engineer before plantation. Cordia dichotoma

15

-

-

... More
Providing, laying and planting various Trees & Palms as listed below as per the mentioned size including adding fertilizers as per planting schedule, manure and Neem cake etc. including their maintainance upto 3 months during which the contractor is suppose to maintain all these in all respects such as watering, pruning, spraying of pesticides, fungicides, insecticides, adding fertilisers, removing of weeds as per specification and direction of the Engineer and also replacing with similar plants in case of death of any plants. The plant will be selected and approved by the Engineer before plantation. Mimusops elengii

12

-

-

... More
Providing, laying and planting various Trees & Palms as listed below as per the mentioned size including adding fertilizers as per planting schedule, manure and Neem cake etc. including their maintainance upto 3 months during which the contractor is suppose to maintain all these in all respects such as watering, pruning, spraying of pesticides, fungicides, insecticides, adding fertilisers, removing of weeds as per specification and direction of the Engineer and also replacing with similar plants in case of death of any plants. The plant will be selected and approved by the Engineer before plantation. Michelia champaka

15

-

-

... More
Providing, laying and planting various Trees & Palms as listed below as per the mentioned size including adding fertilizers as per planting schedule, manure and Neem cake etc. including their maintainance upto 3 months during which the contractor is suppose to maintain all these in all respects such as watering, pruning, spraying of pesticides, fungicides, insecticides, adding fertilisers, removing of weeds as per specification and direction of the Engineer and also replacing with similar plants in case of death of any plants. The plant will be selected and approved by the Engineer before plantation. Plumeria alba

3

-

-

... More
Providing, laying and planting various Trees & Palms as listed below as per the mentioned size including adding fertilizers as per planting schedule, manure and Neem cake etc. including their maintainance upto 3 months during which the contractor is suppose to maintain all these in all respects such as watering, pruning, spraying of pesticides, fungicides, insecticides, adding fertilisers, removing of weeds as per specification and direction of the Engineer and also replacing with similar plants in case of death of any plants. The plant will be selected and approved by the Engineer before plantation. Plumeria rubra

3

-

-

... More
Providing, laying and planting various Trees & Palms as listed below as per the mentioned size including adding fertilizers as per planting schedule, manure and Neem cake etc. including their maintainance upto 3 months during which the contractor is suppose to maintain all these in all respects such as watering, pruning, spraying of pesticides, fungicides, insecticides, adding fertilisers, removing of weeds as per specification and direction of the Engineer and also replacing with similar plants in case of death of any plants. The plant will be selected and approved by the Engineer before plantation. Khaya senegalensis

15

-

-

... More
Providing, laying and planting various Trees & Palms as listed below as per the mentioned size including adding fertilizers as per planting schedule, manure and Neem cake etc. including their maintainance upto 3 months during which the contractor is suppose to maintain all these in all respects such as watering, pruning, spraying of pesticides, fungicides, insecticides, adding fertilisers, removing of weeds as per specification and direction of the Engineer and also replacing with similar plants in case of death of any plants. The plant will be selected and approved by the Engineer before plantation. Cassia fistula

28

-

-

... More
Providing, laying and planting various Trees & Palms as listed below as per the mentioned size including adding fertilizers as per planting schedule, manure and Neem cake etc. including their maintainance upto 3 months during which the contractor is suppose to maintain all these in all respects such as watering, pruning, spraying of pesticides, fungicides, insecticides, adding fertilisers, removing of weeds as per specification and direction of the Engineer and also replacing with similar plants in case of death of any plants. The plant will be selected and approved by the Engineer before plantation. Phyllostachys aurea

10

-

-

... More
Providing, laying and planting various Trees & Palms as listed below as per the mentioned size including adding fertilizers as per planting schedule, manure and Neem cake etc. including their maintainance upto 3 months during which the contractor is suppose to maintain all these in all respects such as watering, pruning, spraying of pesticides, fungicides, insecticides, adding fertilisers, removing of weeds as per specification and direction of the Engineer and also replacing with similar plants in case of death of any plants. The plant will be selected and approved by the Engineer before plantation. Mangifera indica

22

-

-

... More
Providing, laying and planting various Trees & Palms as listed below as per the mentioned size including adding fertilizers as per planting schedule, manure and Neem cake etc. including their maintainance upto 3 months during which the contractor is suppose to maintain all these in all respects such as watering, pruning, spraying of pesticides, fungicides, insecticides, adding fertilisers, removing of weeds as per specification and direction of the Engineer and also replacing with similar plants in case of death of any plants. The plant will be selected and approved by the Engineer before plantation. Raphis exaltata

8

-

-

... More
Providing, laying and planting various Trees & Palms as listed below as per the mentioned size including adding fertilizers as per planting schedule, manure and Neem cake etc. including their maintainance upto 3 months during which the contractor is suppose to maintain all these in all respects such as watering, pruning, spraying of pesticides, fungicides, insecticides, adding fertilisers, removing of weeds as per specification and direction of the Engineer and also replacing with similar plants in case of death of any plants. The plant will be selected and approved by the Engineer before plantation. Erythrina indica

3

-

-

... More
Providing, laying and planting various Trees & Palms as listed below as per the mentioned size including adding fertilizers as per planting schedule, manure and Neem cake etc. including their maintainance upto 3 months during which the contractor is suppose to maintain all these in all respects such as watering, pruning, spraying of pesticides, fungicides, insecticides, adding fertilisers, removing of weeds as per specification and direction of the Engineer and also replacing with similar plants in case of death of any plants. The plant will be selected and approved by the Engineer before plantation. Plumeria Singaporensis

8

-

-

... More
Providing, laying and planting various Trees & Palms as listed below as per the mentioned size including adding fertilizers as per planting schedule, manure and Neem cake etc. including their maintainance upto 3 months during which the contractor is suppose to maintain all these in all respects such as watering, pruning, spraying of pesticides, fungicides, insecticides, adding fertilisers, removing of weeds as per specification and direction of the Engineer and also replacing with similar plants in case of death of any plants. The plant will be selected and approved by the Engineer before plantation. Wodyetia bifurcata

21

-

-

... More
Providing, laying and planting various Trees & Palms as listed below as per the mentioned size including adding fertilizers as per planting schedule, manure and Neem cake etc. including their maintainance upto 3 months during which the contractor is suppose to maintain all these in all respects such as watering, pruning, spraying of pesticides, fungicides, insecticides, adding fertilisers, removing of weeds as per specification and direction of the Engineer and also replacing with similar plants in case of death of any plants. The plant will be selected and approved by the Engineer before plantation. Cyrtostachys renda

35

-

-

... More
Providing, laying and planting various Trees & Palms as listed below as per the mentioned size including adding fertilizers as per planting schedule, manure and Neem cake etc. including their maintainance upto 3 months during which the contractor is suppose to maintain all these in all respects such as watering, pruning, spraying of pesticides, fungicides, insecticides, adding fertilisers, removing of weeds as per specification and direction of the Engineer and also replacing with similar plants in case of death of any plants. The plant will be selected and approved by the Engineer before plantation. Howea forsteriana

15

-

-

... More
Supplying & Planting shrubs, creepers, ground covers, as listed below as per the mentioned size including adding fertilizers as per planting schedule, manure and Neem cake etc. including their maintainance upto 3 months during which the contractor is suppose to maintain all these in all respects such as watering, pruning, spraying of pesticides, fungicides, insecticides, adding fertilisers, removing of weeds as per specification and direction of the Engineer and also replacing with similar plants in case of death of any plants. The plant will be selected and approved by the Engineer before plantation. Schedule of Shrubs Ophiopogon japonicus mini

6290

-

-

... More
Supplying & Planting shrubs, creepers, ground covers, as listed below as per the mentioned size including adding fertilizers as per planting schedule, manure and Neem cake etc. including their maintainance upto 3 months during which the contractor is suppose to maintain all these in all respects such as watering, pruning, spraying of pesticides, fungicides, insecticides, adding fertilisers, removing of weeds as per specification and direction of the Engineer and also replacing with similar plants in case of death of any plants. The plant will be selected and approved by the Engineer before plantation. Schedule of Shrubs Ophiopogon japonicus medium

8115

-

-

... More
Supplying & Planting shrubs, creepers, ground covers, as listed below as per the mentioned size including adding fertilizers as per planting schedule, manure and Neem cake etc. including their maintainance upto 3 months during which the contractor is suppose to maintain all these in all respects such as watering, pruning, spraying of pesticides, fungicides, insecticides, adding fertilisers, removing of weeds as per specification and direction of the Engineer and also replacing with similar plants in case of death of any plants. The plant will be selected and approved by the Engineer before plantation. Schedule of Shrubs wedelia trilobata

4660

-

-

... More
Supplying & Planting shrubs, creepers, ground covers, as listed below as per the mentioned size including adding fertilizers as per planting schedule, manure and Neem cake etc. including their maintainance upto 3 months during which the contractor is suppose to maintain all these in all respects such as watering, pruning, spraying of pesticides, fungicides, insecticides, adding fertilisers, removing of weeds as per specification and direction of the Engineer and also replacing with similar plants in case of death of any plants. The plant will be selected and approved by the Engineer before plantation. Schedule of Shrubs Dianella tasmanica green

4280

-

-

... More
Supplying & Planting shrubs, creepers, ground covers, as listed below as per the mentioned size including adding fertilizers as per planting schedule, manure and Neem cake etc. including their maintainance upto 3 months during which the contractor is suppose to maintain all these in all respects such as watering, pruning, spraying of pesticides, fungicides, insecticides, adding fertilisers, removing of weeds as per specification and direction of the Engineer and also replacing with similar plants in case of death of any plants. The plant will be selected and approved by the Engineer before plantation. Schedule of Shrubs Dianella tasmanica verigated

3830

-

-

... More
Supplying & Planting shrubs, creepers, ground covers, as listed below as per the mentioned size including adding fertilizers as per planting schedule, manure and Neem cake etc. including their maintainance upto 3 months during which the contractor is suppose to maintain all these in all respects such as watering, pruning, spraying of pesticides, fungicides, insecticides, adding fertilisers, removing of weeds as per specification and direction of the Engineer and also replacing with similar plants in case of death of any plants. The plant will be selected and approved by the Engineer before plantation. Schedule of Shrubs Rhoeo Spathacea

1080

-

-

... More
Supplying & Planting shrubs, creepers, ground covers, as listed below as per the mentioned size including adding fertilizers as per planting schedule, manure and Neem cake etc. including their maintainance upto 3 months during which the contractor is suppose to maintain all these in all respects such as watering, pruning, spraying of pesticides, fungicides, insecticides, adding fertilisers, removing of weeds as per specification and direction of the Engineer and also replacing with similar plants in case of death of any plants. The plant will be selected and approved by the Engineer before plantation. Schedule of Shrubs Plumbago capensis

1020

-

-

... More
Supplying & Planting shrubs, creepers, ground covers, as listed below as per the mentioned size including adding fertilizers as per planting schedule, manure and Neem cake etc. including their maintainance upto 3 months during which the contractor is suppose to maintain all these in all respects such as watering, pruning, spraying of pesticides, fungicides, insecticides, adding fertilisers, removing of weeds as per specification and direction of the Engineer and also replacing with similar plants in case of death of any plants. The plant will be selected and approved by the Engineer before plantation. Schedule of Shrubs Alpinia zerumbet

320

-

-

... More
Supplying & Planting shrubs, creepers, ground covers, as listed below as per the mentioned size including adding fertilizers as per planting schedule, manure and Neem cake etc. including their maintainance upto 3 months during which the contractor is suppose to maintain all these in all respects such as watering, pruning, spraying of pesticides, fungicides, insecticides, adding fertilisers, removing of weeds as per specification and direction of the Engineer and also replacing with similar plants in case of death of any plants. The plant will be selected and approved by the Engineer before plantation. Schedule of Shrubs Spathyphyllum wallisii

515

-

-

... More
Supplying & Planting shrubs, creepers, ground covers, as listed below as per the mentioned size including adding fertilizers as per planting schedule, manure and Neem cake etc. including their maintainance upto 3 months during which the contractor is suppose to maintain all these in all respects such as watering, pruning, spraying of pesticides, fungicides, insecticides, adding fertilisers, removing of weeds as per specification and direction of the Engineer and also replacing with similar plants in case of death of any plants. The plant will be selected and approved by the Engineer before plantation. Schedule of Shrubs Heliconia psittacorum

160

-

-

... More
Supplying & Planting shrubs, creepers, ground covers, as listed below as per the mentioned size including adding fertilizers as per planting schedule, manure and Neem cake etc. including their maintainance upto 3 months during which the contractor is suppose to maintain all these in all respects such as watering, pruning, spraying of pesticides, fungicides, insecticides, adding fertilisers, removing of weeds as per specification and direction of the Engineer and also replacing with similar plants in case of death of any plants. The plant will be selected and approved by the Engineer before plantation. Schedule of Shrubs Syngonium Podophyllum

1285

-

-

... More
Supplying & Planting shrubs, creepers, ground covers, as listed below as per the mentioned size including adding fertilizers as per planting schedule, manure and Neem cake etc. including their maintainance upto 3 months during which the contractor is suppose to maintain all these in all respects such as watering, pruning, spraying of pesticides, fungicides, insecticides, adding fertilisers, removing of weeds as per specification and direction of the Engineer and also replacing with similar plants in case of death of any plants. The plant will be selected and approved by the Engineer before plantation. Schedule of Shrubs Hydrangea mycrophylla

1680

-

-

... More
Supplying & Planting shrubs, creepers, ground covers, as listed below as per the mentioned size including adding fertilizers as per planting schedule, manure and Neem cake etc. including their maintainance upto 3 months during which the contractor is suppose to maintain all these in all respects such as watering, pruning, spraying of pesticides, fungicides, insecticides, adding fertilisers, removing of weeds as per specification and direction of the Engineer and also replacing with similar plants in case of death of any plants. The plant will be selected and approved by the Engineer before plantation. Schedule of Shrubs Hymenocallis littoralis

965

-

-

... More
Supplying & Planting shrubs, creepers, ground covers, as listed below as per the mentioned size including adding fertilizers as per planting schedule, manure and Neem cake etc. including their maintainance upto 3 months during which the contractor is suppose to maintain all these in all respects such as watering, pruning, spraying of pesticides, fungicides, insecticides, adding fertilisers, removing of weeds as per specification and direction of the Engineer and also replacing with similar plants in case of death of any plants. The plant will be selected and approved by the Engineer before plantation. Schedule of Shrubs Hamelia patens dwarf

430

-

-

... More
Supplying & Planting shrubs, creepers, ground covers, as listed below as per the mentioned size including adding fertilizers as per planting schedule, manure and Neem cake etc. including their maintainance upto 3 months during which the contractor is suppose to maintain all these in all respects such as watering, pruning, spraying of pesticides, fungicides, insecticides, adding fertilisers, removing of weeds as per specification and direction of the Engineer and also replacing with similar plants in case of death of any plants. The plant will be selected and approved by the Engineer before plantation. Schedule of Shrubs Crinum latifolium

1505

-

-

... More
Supplying & Planting shrubs, creepers, ground covers, as listed below as per the mentioned size including adding fertilizers as per planting schedule, manure and Neem cake etc. including their maintainance upto 3 months during which the contractor is suppose to maintain all these in all respects such as watering, pruning, spraying of pesticides, fungicides, insecticides, adding fertilisers, removing of weeds as per specification and direction of the Engineer and also replacing with similar plants in case of death of any plants. The plant will be selected and approved by the Engineer before plantation. Schedule of Shrubs Cymbopogon citratus

880

-

-

... More
Supplying & Planting shrubs, creepers, ground covers, as listed below as per the mentioned size including adding fertilizers as per planting schedule, manure and Neem cake etc. including their maintainance upto 3 months during which the contractor is suppose to maintain all these in all respects such as watering, pruning, spraying of pesticides, fungicides, insecticides, adding fertilisers, removing of weeds as per specification and direction of the Engineer and also replacing with similar plants in case of death of any plants. The plant will be selected and approved by the Engineer before plantation. Schedule of Shrubs Alocasia macrorrhizos

5

-

-

... More
Supplying & Planting shrubs, creepers, ground covers, as listed below as per the mentioned size including adding fertilizers as per planting schedule, manure and Neem cake etc. including their maintainance upto 3 months during which the contractor is suppose to maintain all these in all respects such as watering, pruning, spraying of pesticides, fungicides, insecticides, adding fertilisers, removing of weeds as per specification and direction of the Engineer and also replacing with similar plants in case of death of any plants. The plant will be selected and approved by the Engineer before plantation. Schedule of Shrubs Heliconia Rostrata

645

-

-

... More
Supplying & Planting shrubs, creepers, ground covers, as listed below as per the mentioned size including adding fertilizers as per planting schedule, manure and Neem cake etc. including their maintainance upto 3 months during which the contractor is suppose to maintain all these in all respects such as watering, pruning, spraying of pesticides, fungicides, insecticides, adding fertilisers, removing of weeds as per specification and direction of the Engineer and also replacing with similar plants in case of death of any plants. The plant will be selected and approved by the Engineer before plantation. Schedule of Shrubs Heliconia Metalica

240

-

-

... More
Supplying & Planting shrubs, creepers, ground covers, as listed below as per the mentioned size including adding fertilizers as per planting schedule, manure and Neem cake etc. including their maintainance upto 3 months during which the contractor is suppose to maintain all these in all respects such as watering, pruning, spraying of pesticides, fungicides, insecticides, adding fertilisers, removing of weeds as per specification and direction of the Engineer and also replacing with similar plants in case of death of any plants. The plant will be selected and approved by the Engineer before plantation. Schedule of Shrubs Calathea Lutea

175

-

-

... More
Supplying & Planting shrubs, creepers, ground covers, as listed below as per the mentioned size including adding fertilizers as per planting schedule, manure and Neem cake etc. including their maintainance upto 3 months during which the contractor is suppose to maintain all these in all respects such as watering, pruning, spraying of pesticides, fungicides, insecticides, adding fertilisers, removing of weeds as per specification and direction of the Engineer and also replacing with similar plants in case of death of any plants. The plant will be selected and approved by the Engineer before plantation. Schedule of Shrubs pennisetum rubrum

290

-

-

... More
Supplying & Planting shrubs, creepers, ground covers, as listed below as per the mentioned size including adding fertilizers as per planting schedule, manure and Neem cake etc. including their maintainance upto 3 months during which the contractor is suppose to maintain all these in all respects such as watering, pruning, spraying of pesticides, fungicides, insecticides, adding fertilisers, removing of weeds as per specification and direction of the Engineer and also replacing with similar plants in case of death of any plants. The plant will be selected and approved by the Engineer before plantation. Schedule of Shrubs pennisetum setaceum

140

-

-

... More
Supplying & Planting shrubs, creepers, ground covers, as listed below as per the mentioned size including adding fertilizers as per planting schedule, manure and Neem cake etc. including their maintainance upto 3 months during which the contractor is suppose to maintain all these in all respects such as watering, pruning, spraying of pesticides, fungicides, insecticides, adding fertilisers, removing of weeds as per specification and direction of the Engineer and also replacing with similar plants in case of death of any plants. The plant will be selected and approved by the Engineer before plantation. Schedule of Shrubs canna indica

530

-

-

... More
Supplying & Planting shrubs, creepers, ground covers, as listed below as per the mentioned size including adding fertilizers as per planting schedule, manure and Neem cake etc. including their maintainance upto 3 months during which the contractor is suppose to maintain all these in all respects such as watering, pruning, spraying of pesticides, fungicides, insecticides, adding fertilisers, removing of weeds as per specification and direction of the Engineer and also replacing with similar plants in case of death of any plants. The plant will be selected and approved by the Engineer before plantation. Schedule of Shrubs alpinia purpurata

130

-

-

... More
Supplying & Planting shrubs, creepers, ground covers, as listed below as per the mentioned size including adding fertilizers as per planting schedule, manure and Neem cake etc. including their maintainance upto 3 months during which the contractor is suppose to maintain all these in all respects such as watering, pruning, spraying of pesticides, fungicides, insecticides, adding fertilisers, removing of weeds as per specification and direction of the Engineer and also replacing with similar plants in case of death of any plants. The plant will be selected and approved by the Engineer before plantation. Schedule of Shrubs strelitzia reginae

680

-

-

... More
Supplying & Planting shrubs, creepers, ground covers, as listed below as per the mentioned size including adding fertilizers as per planting schedule, manure and Neem cake etc. including their maintainance upto 3 months during which the contractor is suppose to maintain all these in all respects such as watering, pruning, spraying of pesticides, fungicides, insecticides, adding fertilisers, removing of weeds as per specification and direction of the Engineer and also replacing with similar plants in case of death of any plants. The plant will be selected and approved by the Engineer before plantation. Schedule of Shrubs strelitzia parviflora

485

-

-

... More
Supplying & Planting shrubs, creepers, ground covers, as listed below as per the mentioned size including adding fertilizers as per planting schedule, manure and Neem cake etc. including their maintainance upto 3 months during which the contractor is suppose to maintain all these in all respects such as watering, pruning, spraying of pesticides, fungicides, insecticides, adding fertilisers, removing of weeds as per specification and direction of the Engineer and also replacing with similar plants in case of death of any plants. The plant will be selected and approved by the Engineer before plantation. Schedule of Shrubs agave attenuata

10

-

-

... More
Supplying & Planting shrubs, creepers, ground covers, as listed below as per the mentioned size including adding fertilizers as per planting schedule, manure and Neem cake etc. including their maintainance upto 3 months during which the contractor is suppose to maintain all these in all respects such as watering, pruning, spraying of pesticides, fungicides, insecticides, adding fertilisers, removing of weeds as per specification and direction of the Engineer and also replacing with similar plants in case of death of any plants. The plant will be selected and approved by the Engineer before plantation. Schedule of Shrubs zephyranthes candida

2005

-

-

... More
Supplying & Planting shrubs, creepers, ground covers, as listed below as per the mentioned size including adding fertilizers as per planting schedule, manure and Neem cake etc. including their maintainance upto 3 months during which the contractor is suppose to maintain all these in all respects such as watering, pruning, spraying of pesticides, fungicides, insecticides, adding fertilisers, removing of weeds as per specification and direction of the Engineer and also replacing with similar plants in case of death of any plants. The plant will be selected and approved by the Engineer before plantation. Schedule of Shrubs zephyranthes grandiflora

3635

-

-

... More
Grassing with Selection One Lawn including adding fertilizers as per planting schedule, manure and Neem cake etc. including their maintainance upto 3 months during which the contractor is suppose to maintain all these in all respects such as watering, pruning, spraying of pesticides, fungicides, insecticides, adding fertilisers, removing of weeds as per specification and direction of the Engineer and also replacing with similar lawn in case of death of any portion.

3221.4

-

-

... More
PLUMBING WORKS

-

-

-

... More
Proving and fixing white vitreous china Wall Hung type (European Type) water closet with seat and lid with C.I. brass hinges and rubber fittings with flush valve nelson/ similar fully chromium plated with stop cock, wall flanges, flush pipe or elbow and vaccum breaker coupling etc. including chair bracket/rag bolts, cutting & making good the walls and floors where required and concealed seat support - W.C. Pan with white plastic seat and lid

57

-

-

... More
Providing and fixing Hand Shower (Health Faucet) with 8mm dia, ABS/brass body with double lock 1.00m long Flexible tube (Brass plated stainles steel flexible hose) and wall hook of approved quality confirming to IS standards.

57

-

-

... More
Providing and fixing NICKEL chrome plated copper alloy Fancy Two Way Bib Cock with single knob and wall flange conforming to IS 8931:1993 15mm nominal bore.

57

-

-

... More
Providing and fixing NICKEL chrome plated copper alloy Fancy BIB Cock Short Body Jaquar make or equivalent. Confirming to IS 8931;1993

24

-

-

... More
Providing and fixing white vitreous china flat back Large lipped front urinal basin of 590x375x390mm size with Urinal Valve Auto closing system with built in control cock & wall flange with fittings, spreader, R.S. or C.I. brackets, standard size C.P. Brassl flush pipe and spreaders with C. P. brass unions & C. P. Brass clamps with waste fitting as per IS 2556, PVC trap with outlet grating and other couplings in CP Brass complete, including painting, fittings, cutting and making good the walls and floors where required. - Range of one urinal basin

53

-

-

... More
Providing and fixing vitreous china wash basin with RS or C.I. brackets painted white, 15 mm C.P. brass pillar taps C.P. brass chain with rubber plug 32 mm C.P. brass waste of pattern, 32 mm diameter M.I. or C.P. brass trap and union complete, including cutting and making good the walls where required.

61

-

-

... More
Providing and fixing Stainless Steel A ISI 304 (18/8) kitchen sink as per IS: 13983 including cutting of stone and making good the walls wherever required : Kitchen sink with drain board with coupling & all accessories complete with choke stop strainer, Plain type having flat borders for correct sandwithing between the plaform top and bottom slabs complete a. Overall size 1040mmx510mm (41"x20") bowl size 460mmx410mmx200mm (18"x 16"x 8") depth 200 mm. Glossy. 1.0mm thk,

17

-

-

... More
Providing and fixing low flow rate C.P sink mixer with extended swinging spout, etc with complete accessories

17

-

-

... More
Providing and fixing low flow rate C.P sink cock with extended swinging spout, etc with complete accessories

17

-

-

... More
Providing and Fixing toilet paper holder C.P. Brass

51

-

-

... More
Providing & fixing liquid soap container with C. P. brass lid and brackets fixed to wooden cleats with C. P. brass screws Glass container

61

-

-

... More
Providing and fixing 300mm long SS Grab Bar as per approved makek etc. Complete.

6

-

-

... More
Providing & fixing fully automatic "NO TOUCH" satin finish stainless steel AISI 316 grade wall mounted hand drier suitable to operate on 240 volts, single phase 50 hz, A.C. power supply, ( motor rating 100W, 2850 rpm automatic infrared sensing device, 1600W heating element approximate 275 cum/hr air flow wind velocity 15.5 m/sec or as per Manufacturer's specifications)

20

-

-

... More
Supplying, erecting, testing and commissioning self contained water cooler 230/250V 50Hz with inbuilt RO and nominal cooling capacity of 150 litres per hour and storage capacity 150 litres with stainless steel body as per specification no. APWCR/WC

10

-

-

... More
Providing and fixing C.P. brass angle valve of approved quality conforming to IS:8931 (15mm nominal bore)

71

-

-

... More
Providing & fixing 150 mm SS 304 ACO Kitchen drain chanel including SS 304 grating on top.

1

-

-

... More
Providing & fixing 600mm long flexible braided hose of approved quality

88

-

-

... More
Providing and fixing nahani trap of rigid PVC (approved make) for S.W.R. Pipes including lubricating etc. complete, without door : 110mm

77

-

-

... More
Providing and fixing nahani trap of rigid PVC (approved make) for S.W.R. Pipes including lubricating etc. complete, without door : 75mm

26

-

-

... More
Providing & fixing Stainless steel perforated grating over Nahani trap for wash basins, shower, sinks, etc, with all necessary cutting, filling, fixing & making good the services, etc,complete.

83

-

-

... More
Providing and fixing rigid PVC S.W. R. (soil, waste and rain water drainage pipes of approved make including lubricant etc. complete (single/double) socketed : 110mm dia

236.5

-

-

... More
Providing and fixing rigid PVC S.W. R. (soil, waste and rain water drainage pipes of approved make including lubricant etc. complete (single/double) socketed : 75mm dia

344

-

-

... More
Providing and fixing rigid PVC bend of required degree (of approved make) for S.W.R. drainage pipes of approved including lubricating. 110mm

300

-

-

... More
Providing and fixing rigid PVC bend of required degree (of approved make) for S.W.R. drainage pipes of approved including lubricating. 75mm

100

-

-

... More
Providing and fixing rigid PVC bend (approved make ) for S.W.R. pipes including lubricating etc complete bend with door : 110mm

90

-

-

... More
Providing and fixing rigid PVC bend (approved make ) for S.W.R. pipes including lubricating etc complete bend with door : 75 mm

60

-

-

... More
Providing and fixing single Tee of rigid PVC (approved make ) for S.W.R. pipes including lubricating etc complete, with door : 110mm

10

-

-

... More
Providing and fixing single “Y” of rigid PVC (approved make ) for S.W.R. pipes including lubricating etc complete, without door 110mm

100

-

-

... More
Providing and fixing single “Y” of rigid PVC (approved make ) for S.W.R. pipes including lubricating etc complete, without door 75mm

170

-

-

... More
Providing and fixing R.P.V.C. vent cowl: 110mm

10

-

-

... More
Providing and fixing R.P.V.C. vent cowl: 75mm

8

-

-

... More
Providing and fixing Upvc SWR pipes Type B for wash basin, Sink and Urinal drainage outlet laid in floor & sunk, chiseling in walls etc., with necessary cutting to the required length including short pieces Assorted fittings such as Plug/Plain Tee and bend single / double Y, Offsets, vent cowl etc. jointing with solvent and giving water tightness test for the pipes laid in the sunken/ceiling suspended portion with making holes in brick walls/floor grooving & redoing the same and provide brick & clamps support whenever required necessary etc. complete. 40mm

159.5

-

-

... More
Providing and fixing Upvc SWR pipes Type B for wash basin, Sink and Urinal drainage outlet laid in floor & sunk, chiseling in walls etc., with necessary cutting to the required length including short pieces Assorted fittings such as Plug/Plain Tee and bend single / double Y, Offsets, vent cowl etc. jointing with solvent and giving water tightness test for the pipes laid in the sunken/ceiling suspended portion with making holes in brick walls/floor grooving & redoing the same and provide brick & clamps support whenever required necessary etc. complete. 50mm

306.9

-

-

... More
Supplying at store or site of work including loading, unloading and stacking at site PVC (RING FIT) pipes with elastomeric sealing ring (one per pipe) and with rubber ring socket, conforming to to IS:4985-2000,and bearing ISI mark Class 6kg/sq.cm. Outer Dia in mm 75mm

88

-

-

... More
Supplying at store or site of work including loading, unloading and stacking at site PVC (RING FIT) pipes with elastomeric sealing ring (one per pipe) and with rubber ring socket, conforming to to IS:4985-2000,and bearing ISI mark Class 6kg/sq.cm. Outer Dia in mm 110mm

132

-

-

... More
Supplying at store or site of work including loading, unloading and stacking at site PVC (RING FIT) pipes with elastomeric sealing ring (one per pipe) and with rubber ring socket, conforming to to IS:4985-2000,and bearing ISI mark Class 6kg/sq.cm. Outer Dia in mm 160mm

825

-

-

... More
Construction of manhole rectangular in shape including cement concrete 1:3:6 (1 cement:3 coarse sand:6 graded stone aggregate 20mm nominal size) foundation thickness of concrete 20cms and offset 10cms on both sides and first class brick work with bricks class designation 100kg/sq.cm (wire cut bricks) cement mortar 1:3 (1 cement : 3 coarse sand) 23cms thick including providing & fixing CI footrests confirming to IS 5445/69 or revised and whose weight shall not be less than 5.30kgs including fixing in man-hole at 30cm c / c in 20x 20x10cm cement concrete block 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20mm nominal size) and 12mm thick plaster inside and outside with cement mortar 1:3 (1 cement : 3 coarse sand) including adding waterproofing compound of approved brand in cement mortar with a floating coat of neat cement and making channel in cement concrete 1:2:4 (1 cement :2 coarse sand : 4 graded stone aggregate 20m nominal size) neatly finished complete as per standard design. Inside size 0.60x0.60m and 0.60m deep (with medium duty DI manhole cover & frame of size 0.60x 0.60m weighing 90kgs ) including fixing with cement concrete 1:2:4 ( 1 cement :2 coarse sand : 4 graded stone aggregate 20mm nominal size and applying the frame & cover with coal tar.

30

-

-

... More
Construction of manhole rectangular in shape including cement concrete 1:3:6 (1 cement:3 coarse sand:6 graded stone aggregate 20mm nominal size) foundation thickness of concrete 20cms and offset 10cms on both sides and first class brick work with bricks class designation 100kg/sq.cm (wire cut bricks) cement mortar 1:3 (1 cement : 3 coarse sand) 23cms thick including providing & fixing CI footrests confirming to IS 5445/69 or revised and whose weight shall not be less than 5.30kgs including fixing in man-hole at 30cm c / c in 20x 20x10cm cement concrete block 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20mm nominal size) and 12mm thick plaster inside and outside with cement mortar 1:3 (1 cement : 3 coarse sand) including adding waterproofing compound of approved brand in cement mortar with a floating coat of neat cement and making channel in cement concrete 1:2:4 (1 cement :2 coarse sand : 4 graded stone aggregate 20m nominal size) neatly finished complete as per standard design.Inside size 0.90 x 0.60m and 1.00m deep ( with medium duty DI manhole cover & frame of size 0.90x 0.60m weighing 105 kgs including fixing with cement concrete 1:2:4 ( 1 cement : 2 coarse sand : 4 graded stone aggregate 20mm nominal size and applying the frame & cover with coal tar.)

15

-

-

... More
Construction of manhole conical in shape including cement concrete 1:2:4 ( 1 cement:2coarse sand:4 graded stone aggregate 20mm nominal size) foundation thickness of concrete 25cms and offset 15cms on both sides and first class brick work with bricks class designation 100kg/sq.cm(wire cut bricks) in cement mortar 1:3 (1 cement : 3 coarse sand) 35cms thick including providing & fixing CI footrests confirming to IS 5445/69 or revised and whose weight shall not be less than 5.30kgs including fixing in man-hole at 30cm c/c in 20 x 20 x 10cm cement concrete block 1:2:4 ( 1 cement : 2 coarse sand : 4 graded stone aggregate 20mm nominal size) and 12mm thick plaster inside and outside with cement mortar 1:3 (1 cement : 3 coarse sand) including adding waterproofing compound of approved brand in cement mortar with a floating coat of neat cement and making channel in cement concrete 1:2:4 ( 1 cement :2 coarse sand : 4 graded stone aggregate 20m nominal size) neatly finished including providing and fixing manhole cover and frame in cement concrete 1:2:4 ( 1 cement : 2 coarse sand : 4 graded stone aggregate 20mm nominal size) complete as per standard design. With 500 mm Dia heavy duty solid type C.I. circular cover and frame weighing not less then 230 kgs.0.9m dia b) 1.5 m deep

4

-

-

... More
Providing and fixing square mouth S.W. gully trap grade 'A" complete with C.I. Grading brick masonry chamber and water light C.I. cover with frame 300x300mm size (inside) the weight of the cover to be not less than 4.53kg and frame to be not less than 2.72kg as per standard design. b) 150 x 100 mm size P or S type

7

-

-

... More
Providing and fixing C.I. foot rest having minimum weight 5.3 kgs in manhole with 20x20x10cm cement concrete blocks 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20mm nominal size) as per standard design.

50

-

-

... More
Providing at store or site work non-pressure RCC pipes of with collar joints conforming to IS:458-2003 revised as per amendment No.11 , including freight, carting, loading, unloading, stacking etc. complete.I)NP2 Class150

385

-

-

... More
Conveying carefully from stack at site, 250m from both sides rolling and lowering into trenches, laying and jointing true to line and level, RCC spun pressure and non-pressure pipes of various classes, specials including collar and perfect linking of joint with jack to correct position including cost of jointing material in cement mortar 1:2, necessary hydraulic testing, curing of cement mortar etc. complete.150

385

-

-

... More
Supplying and fixing air tight FRP cover (LD) with frame of size 900 x 600 mm for manholes opening of water tanks including required accessories & materials etc. complate as per direction of engineer in charge.

13

-

-

... More
Providing and fixing ASTM UPVC pipe, conforming to ASTM 2467 with ISO 14001, including all UPVC plain & brass threaded fittings, including jointing of pipes & fittings with one step UPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer. External work. (All Domestic & flushing water supply lines in duct & terrace loop by gravity & toilet internal concealed piping above 50mm dia) SCH -40 ( blue/white) Outer Dia in mm 20

15

-

-

... More
Providing and fixing ASTM UPVC pipe, conforming to ASTM 2467 with ISO 14001, including all UPVC plain & brass threaded fittings, including jointing of pipes & fittings with one step UPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer. External work. (All Domestic & flushing water supply lines in duct & terrace loop by gravity & toilet internal concealed piping above 50mm dia) SCH -40 ( blue/white) Outer Dia in mm 25

15

-

-

... More
Providing and fixing ASTM UPVC pipe, conforming to ASTM 2467 with ISO 14001, including all UPVC plain & brass threaded fittings, including jointing of pipes & fittings with one step UPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer. External work. (All Domestic & flushing water supply lines in duct & terrace loop by gravity & toilet internal concealed piping above 50mm dia) SCH -40 ( blue/white) Outer Dia in mm 32

15

-

-

... More
Providing and fixing ASTM UPVC pipe, conforming to ASTM 2467 with ISO 14001, including all UPVC plain & brass threaded fittings, including jointing of pipes & fittings with one step UPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer. External work. (All Domestic & flushing water supply lines in duct & terrace loop by gravity & toilet internal concealed piping above 50mm dia) SCH -40 ( blue/white) Outer Dia in mm 40

308

-

-

... More
Providing and fixing ASTM UPVC pipe, conforming to ASTM 2467 with ISO 14001, including all UPVC plain & brass threaded fittings, including jointing of pipes & fittings with one step UPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer. External work. (All Domestic & flushing water supply lines in duct & terrace loop by gravity & toilet internal concealed piping above 50mm dia) SCH -40 ( blue/white) Outer Dia in mm 50

770

-

-

... More
Providing and fixing ASTM UPVC pipe, conforming to ASTM 2467 with ISO 14001, including all UPVC plain & brass threaded fittings, including jointing of pipes & fittings with one step UPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer. External work. (All Domestic & flushing water supply lines in duct & terrace loop by gravity & toilet internal concealed piping above 50mm dia) SCH -40 ( blue/white) Outer Dia in mm 90

1

-

-

... More
Providing and fixing chlorinated ployvinyl chloride (CPVC) pipes confirming to IS:15778, having thermal stability for hot and cold water supply including all CPVC plain and brass threaded fittings including fixing the pipes with clamps at 1 mt. spacing. This includes jointing of pipes and fittings with one step CPVC solvent cement and testing of joints complete as per direction of the Engineer-in-charge. Internal work exposed on wall (Medium duty SDR 13.5 pipe). (All concealed Domestic & flushing & hot toilet internal water supply & internal drainage) 15 mm outer dia CPVC pipe

231

-

-

... More
Providing and fixing chlorinated ployvinyl chloride (CPVC) pipes confirming to IS:15778, having thermal stability for hot and cold water supply including all CPVC plain and brass threaded fittings including fixing the pipes with clamps at 1 mt. spacing. This includes jointing of pipes and fittings with one step CPVC solvent cement and testing of joints complete as per direction of the Engineer-in-charge. Internal work exposed on wall (Medium duty SDR 13.5 pipe). (All concealed Domestic & flushing & hot toilet internal water supply & internal drainage) 20 mm outer dia CPVC pipe

390.5

-

-

... More
Providing and fixing chlorinated ployvinyl chloride (CPVC) pipes confirming to IS:15778, having thermal stability for hot and cold water supply including all CPVC plain and brass threaded fittings including fixing the pipes with clamps at 1 mt. spacing. This includes jointing of pipes and fittings with one step CPVC solvent cement and testing of joints complete as per direction of the Engineer-in-charge. Internal work exposed on wall (Medium duty SDR 13.5 pipe). (All concealed Domestic & flushing & hot toilet internal water supply & internal drainage) 25 mm outer dia CPVC pipe

269.5

-

-

... More
Providing and fixing chlorinated ployvinyl chloride (CPVC) pipes confirming to IS:15778, having thermal stability for hot and cold water supply including all CPVC plain and brass threaded fittings including fixing the pipes with clamps at 1 mt. spacing. This includes jointing of pipes and fittings with one step CPVC solvent cement and testing of joints complete as per direction of the Engineer-in-charge. Internal work exposed on wall (Medium duty SDR 13.5 pipe). (All concealed Domestic & flushing & hot toilet internal water supply & internal drainage) 32 mm outer dia CPVC pipe

88

-

-

... More
Providing and fixing ASTM UPVC pipe, conforming to ASTM 2467 with ISO 14001, including all UPVC plain & brass threaded fittings, including jointing of pipes & fittings with one step UPVC solvent cement, trenching ,refilling & testing of joints complete as per direction of Engineer. External work. (Underground pressurised water supply line) SCH-80(blue)/(white) 40mm outer dia.

1

-

-

... More
Providing and fixing ASTM UPVC pipe, conforming to ASTM 2467 with ISO 14001, including all UPVC plain & brass threaded fittings, including jointing of pipes & fittings with one step UPVC solvent cement, trenching ,refilling & testing of joints complete as per direction of Engineer. External work. (Underground pressurised water supply line) SCH-80(blue)/(white) 50mm outer dia.

250

-

-

... More
Providing and fixing ASTM UPVC pipe, conforming to ASTM 2467 with ISO 14001, including all UPVC plain & brass threaded fittings, including jointing of pipes & fittings with one step UPVC solvent cement, trenching ,refilling & testing of joints complete as per direction of Engineer. External work. (Underground pressurised water supply line) SCH-80(blue)/(white) 63mm outer dia.

75

-

-

... More
Providing and fixing ASTM UPVC pipe, conforming to ASTM 2467 with ISO 14001, including all UPVC plain & brass threaded fittings, including jointing of pipes & fittings with one step UPVC solvent cement, trenching ,refilling & testing of joints complete as per direction of Engineer. External work. (Underground pressurised water supply line) SCH-80(blue)/(white) 75mm outer dia.

1

-

-

... More
Providing and fixing brass full way valve (heavy) duty with wheel of approved quality : (Total domestic & flushing water supply terrace loop, down take, internal UGR to OHT, drain valves etc.) 20 mm nominal bore

4

-

-

... More
Providing and fixing brass full way valve (heavy) duty with wheel of approved quality : (Total domestic & flushing water supply terrace loop, down take, internal UGR to OHT, drain valves etc.) 25 mm nominal bore

16

-

-

... More
Providing and fixing brass full way valve (heavy) duty with wheel of approved quality : (Total domestic & flushing water supply terrace loop, down take, internal UGR to OHT, drain valves etc.) 32 mm nominal bore

15

-

-

... More
Providing and fixing brass full way valve (heavy) duty with wheel of approved quality : (Total domestic & flushing water supply terrace loop, down take, internal UGR to OHT, drain valves etc.) 40 mm nominal bore .

12

-

-

... More
Providing and fixing brass full way valve (heavy) duty with wheel of approved quality : (Total domestic & flushing water supply terrace loop, down take, internal UGR to OHT, drain valves etc.) 50 mm nominal bore .

10

-

-

... More
Supply of inferential, dry dial, type Domestic Water Meter, suitable for horizontal installation, duly, sealed against tampering with couplings at both ends having pulse output facility compatible for the automatic reading system, conforming to IS:779-1974 and ISO 4064-2005 standards and bearing EEC/MID/OIML mark, (with latest Amendments) along with test certificate from FCRI/NABL as desired by the department. A.Class B-Multi Jet Water meters Dia in mm-50mm

1

-

-

... More
Fixing water meter & stop cock in G. I. Pipe line including cutting & treading the pipe and making long screw etc. complete (cost of water meter and stop cock to be paid separately)

1

-

-

... More
Providing and fixing C.I. Strainers for Water Meters including cost of all materials and labour.C.I. Strainer 'Y' type with screwed ends. Sizes in mm 40

1

-

-

... More
C.I. Stainer 'T' (Basket) type with flanged ends and with stainless steel or Brass mesh with opening of 2.5mm to 3mm and suitable for operating pressure of 16 kg/cm² and test pressure of 24 kg/cm² C.I. Strainer 'T' (Basket) Ttpe with flanged ends Sizes in mm 50mm

1

-

-

... More
C.I. Stainer 'T' (Basket) type with flanged ends and with stainless steel or Brass mesh with opening of 2.5mm to 3mm and suitable for operating pressure of 16 kg/cm² and test pressure of 24 kg/cm² C.I. Strainer 'T' (Basket) Ttpe with flanged ends Sizes in mm 80mm

1

-

-

... More
Providing and fixing ball valve ( brass ) of approved quality : High pressure with PVC float 25 mm nominal bore

2

-

-

... More
Supplying and erecting 100mm dia Cast Iron end line strainer of Y-type flanged end pattern, PN16 pressure rating, SS screen, end connection with Flanged / Screwed / Socket Weld / Butt Weld End etc with standard OAR (openarea Ratio) for positive suction complete as per specification

4

-

-

... More
Supply, Installation, Testing & commissioning of Air release valve with filter & ball valve for water supply risers, suitable for pressure of 10 Kg/Sq.cm. including flanges / union, nuts, bolts, washer etc., complete. Pasting radium Colour band near Valve, Colour text, flow direction arrow on pipe line as per ISO standared. (appropriate tagging should be done for all valves)

10

-

-

... More
Providing, lowering & laying including supply of materials and labour for SN4/SN8 Rigid PVC pipes of approved make, with necessary cutting to the required length including short pieces with assorted fittings etc. jointing with solvent and giving water tightness test for the pipes laid with making holes in brick walls/floor grooving & redoing the same and brick support whenever required necessary etc. complete. All the pipes which will be laid in soil / filling shall be properly supported at all joints, change in dia, direction.etc. works to be executed as per IS complete as per the direction of project engineer. 150 mm dia. (SN4)

275

-

-

... More
Supply, installation, testing, commissioning of 4.6cum/hr capacity water softner plant which includes OBR 46 KLD considering 10 hrs of working ,Regeneration frequncy once in a day, raw water pump (1w +1s) flow rate 4.6 cum/hr @head 350.0m ,M.S.Dual Medai filter with media sand,supporting pebbles & anthresite pressure operating pressure 2.5 kg/cm2,M.S.Softner Unit GIVING 150 obr, automation deatails in which plant will strat on low level in treated water tank and will stop on high level in treated water tank. (process prarameter may change according to water test report)

1

-

-

... More
Supplying & Fixing Prefabricated Sewage Treatment plant of 95 kld with opearting 24 hours of operating,with preatrement which includes screening,oil & grease trap,equliasation tank,secondary treatment which inlides bilogical treatment ,tube settler & disinfecation and sludge disposal sytem,Tertiary treatment as water paased thrugh series of filters, Perforated screen in MS epoxy construction Oil & grease trap chamber Equalisation tank Anoxic Tank MBBR reactors Tube Settler Clear water tank/filter feed tank Treated water tank Sludge holding tank Sewage transfer pumps – Self priming, non clog, centrifugal Air blower with motor, diffuser membrane & associated equipments Tube media for Tube settler Poly dosing system Chlorine dosing system Filter f eed pump Pressure sand filter Activated Carbon filter Interconnecting pipe & fitting, valves Sludge pump Electrical panel & equipment Ozonation & UV Note -1.Stp to treated water tank parameters should meet enviroment standards. 2.STP Vendor need to take all statutaory approval regarding enviromental clerance. 3.STP vendor need to quote for all electromechanical equipment. Contractor have to submit shop drawing before to execution. This cost is excluding all civil works.

1

-

-

... More
WATER PUMP SYSTEM ( INCLUSIVE OF ELECTRICAL PANEL, OUTGOING TO PUMPS AND EARTHING )Discharge - 200 lpm each @ 80 M HEAD (1W+ 1SB) for Domestic water supply system. PUMP SITC, Cost shall be inclusive of Starter Panel, Cabling from Pump to Starter panel, Necessary piping & fittings as per BOQ line Items in same Section, with necessary design modification as per site condition. Pressure rating of all the fitting and accessories shall be suitable for the pump head and system requirement. IE3 RATED MOTORS : All pumps shall be with IE3 motors and overall efficiency of the pump shall be not less than 70%.;All Power & Control Cabling from Starter Panels to Pumps shall be included in the cost of Pumps. Power Cabling for Power Source Panel to Pump Starter Panel will be in scope of Electrical Contractor. Kindly refer PLUMBING PUMP PANEL SCHEMATIC - EMC-617-EL SCH- PL-1.Dewatering sump pump - operation logic shall be set such that if the water level in sump rise above the 75% of the sump depth, all the pumps (working as well standby pumps) will be operational simultaneously. 2 nos. vertical in-line HYPN pumps complete( one working one stand by ) in SS coupled with TEFC motor. Motor and pump shafts are connected with each other via shell couplings. Separate lantern roller bearing for complete hydraulic axial force absorption. With standard three-phase or AC motor (up to max. 1.5 kW), Directly flanged AC motor with built-in thermal motor protection Pump control via electronic pressure and flow monitor with built-in low-water protection and non-return valve. All parts that come into contact with the fluid are corrosion-proof. Pump system ready for connection premounted and wired with 3 m cable and mains plug.. Onsite motor protection for three-phase motor, with VFD suitable for operation on pressure sensing logic complete with required cabling , logic configoration, auto mannual selector .Suitable capacity vessel with interchangable butyl rubber membrane.Electric control panel with change over swich, relays, electrical wiring, cabling from panel to pumps, with VFD operating logic control , approved make required no. of vertical magnetic float switch with 52mm dia SS 316 floats, 2-1/2" table E flange and weather proof enclosure to sense various levels of the overhead tank. cabling from tank to panel with 2 C X 1.5 Sq mm shilded cables,level controller complete with all accessories as per manufacturer specification. Accessories like NRV’s valves, isolating valves, Strainers, SS-304 (non-Magnetic) suction and delivery header, pressure switch, pressure gauge, base frame (synthetic enamel painted over a coat of Primar, isolation mounts and fexible hose connection, reducers and concrete foundation complete as required.

1

-

-

... More
WATER PUMP SYSTEM ( INCLUSIVE OF ELECTRICAL PANEL, OUTGOING TO PUMPS AND EARTHING )Discharge - 200 lpm each @ 80 M HEAD (1W+ 1SB) for fLUSHING water supply system. PUMP SITC, Cost shall be inclusive of Starter Panel, Cabling from Pump to Starter panel, Necessary piping & fittings as per BOQ line Items in same Section, with necessary design modification as per site condition. Pressure rating of all the fitting and accessories shall be suitable for the pump head and system requirement. IE3 RATED MOTORS : All pumps shall be with IE3 motors and overall efficiency of the pump shall be not less than 70%.;All Power & Control Cabling from Starter Panels to Pumps shall be included in the cost of Pumps. Power Cabling for Power Source Panel to Pump Starter Panel will be in scope of Electrical Contractor. Kindly refer PLUMBING PUMP PANEL SCHEMATIC - EMC-617-EL SCH- PL-1.Dewatering sump pump - operation logic shall be set such that if the water level in sump rise above the 75% of the sump depth, all the pumps (working as well standby pumps) will be operational simultaneously. 2 nos. vertical in-line HYPN pumps complete( one working one stand by ) in SS coupled with TEFC motor. Motor and pump shafts are connected with each other via shell couplings. Separate lantern roller bearing for complete hydraulic axial force absorption. With standard three-phase or AC motor (up to max. 1.5 kW), Directly flanged AC motor with built-in thermal motor protection Pump control via electronic pressure and flow monitor with built-in low-water protection and non-return valve. All parts that come into contact with the fluid are corrosion-proof. Pump system ready for connection premounted and wired with 3 m cable and mains plug.. Onsite motor protection for three-phase motor, with VFD suitable for operation on pressure sensing logic complete with required cabling , logic configoration, auto mannual selector .Suitable capacity vessel with interchangable butyl rubber membrane.Electric control panel with change over swich, relays, electrical wiring, cabling from panel to pumps, with VFD operating logic control , approved make required no. of vertical magnetic float switch with 52mm dia SS 316 floats, 2-1/2" table E flange and weather proof enclosure to sense various levels of the overhead tank. cabling from tank to panel with 2 C X 1.5 Sq mm shilded cables,level controller complete with all accessories as per manufacturer specification. Accessories like NRV’s valves, isolating valves, Strainers, SS-304 (non-Magnetic) suction and delivery header, pressure switch, pressure gauge, base frame (synthetic enamel painted over a coat of Primar, isolation mounts and fexible hose connection, reducers and concrete foundation complete as required.

1

-

-

... More
Supplying, installing, testing and commissioning of Water Transfer Pump horizontal / vertical multistage End-suction centrifugal pump. Each pump shall have TEFC 2900 RPM three phase electric motor. The pump shall have cast Iron head, CI base, SS Shaft/ Impeller/ Intermediate chamber. Pump shall be provided with mechanical seal. The pump shall be suitable for auto/ manual operation. The quoted rates shall include the following item.Complete (Skid mounted , wall mounted / floor mounted) electrical control panel with change over switch comprising of all accessories such as Cyclic Timer, Contactors, Single Phasing Preventers, Overload Relays, Push Buttons, Voltmeter, Ammeter, with Selector Switches, A/M Switch, Main Incomer Switch, Dry Run Preventers with float switches, Overflow control with Float Switches, Solenoid valve with Solenoid valve Panel (ones set for each overhead tank), cabling from panel to pumps,control wiring upto tank and any other necessary imports etc.all as per manufacturer specification. (list to be provided by the vendor)Precharged diaphram pressure vessel with food grade membrane, charging connection, connected to outlet header with necessary flanges, gaskets, isolating valves, nuts/bolts etc complete. Set of accessories such as pressure switches, pressure transducers, inter connecting power and control cabling etc. completeRequired nos of cast iron lever operated slim seal type butterfly valves ( as per respective pressure rating) of CI body and spheroidal graphite iron disc (SG iron),with nitrile rubber seal, Confrming to BS 5155 / MF6 standards and including a set of GI flanges as per BS-10 table 1 including bolt nuts, GI washers, and neoprene rubber gaskets Complete etc., on the suction & delivery side of each pump.Industrial type electronic liquid level controllers with stainless steel probes / sensors or float switch for automatic operation. Each pump pressure gauge 4" dial with valve tee and fittings.Accessories like strainers, SS304 suction and delivery header,MS base frame (Synthetic enamel painted over a coat of primer) etc. has to be provided. Each pump suction & discharge flexible connectors as per the respective pressure rating.Each pump Alarm indication with signal in the event of pump failure etc.The pump shall be suitable for the requirements as mentioned below: Discharge -100 Lpm each @ 80 M HEAD (1W+ 1SB) (Domestic water transfer pump at pump room) KCIL 4-14 WITH IE2 MOTOR - all VFD inbuilt PLC IP55 panel - MS Galvanised skid mounted with 100 LTR. Pressure tank

1

-

-

... More
Supplying, installing, testing and commissioning of Water Transfer Pump horizontal / vertical multistage End-suction centrifugal pump. Each pump shall have TEFC 2900 RPM three phase electric motor. The pump shall have cast Iron head, CI base, SS Shaft/ Impeller/ Intermediate chamber. Pump shall be provided with mechanical seal. The pump shall be suitable for auto/ manual operation. The quoted rates shall include the following item.Complete (Skid mounted , wall mounted / floor mounted) electrical control panel with change over switch comprising of all accessories such as Cyclic Timer, Contactors, Single Phasing Preventers, Overload Relays, Push Buttons, Voltmeter, Ammeter, with Selector Switches, A/M Switch, Main Incomer Switch, Dry Run Preventers with float switches, Overflow control with Float Switches, Solenoid valve with Solenoid valve Panel (ones set for each overhead tank), cabling from panel to pumps,control wiring upto tank and any other necessary imports etc.all as per manufacturer specification. (list to be provided by the vendor)Precharged diaphram pressure vessel with food grade membrane, charging connection, connected to outlet header with necessary flanges, gaskets, isolating valves, nuts/bolts etc complete. Set of accessories such as pressure switches, pressure transducers, inter connecting power and control cabling etc. completeRequired nos of cast iron lever operated slim seal type butterfly valves ( as per respective pressure rating) of CI body and spheroidal graphite iron disc (SG iron),with nitrile rubber seal, Confrming to BS 5155 / MF6 standards and including a set of GI flanges as per BS-10 table 1 including bolt nuts, GI washers, and neoprene rubber gaskets Complete etc., on the suction & delivery side of each pump.Industrial type electronic liquid level controllers with stainless steel probes / sensors or float switch for automatic operation. Each pump pressure gauge 4" dial with valve tee and fittings.Accessories like strainers, SS304 suction and delivery header,MS base frame (Synthetic enamel painted over a coat of primer) etc. has to be provided. Each pump suction & discharge flexible connectors as per the respective pressure rating.Each pump Alarm indication with signal in the event of pump failure etc.The pump shall be suitable for the requirements as mentioned below: Discharge -200 Lpm each @ 80 M HEAD (1W+ 1SB) (Flushing water transfer pump at STP room ) KCIL 20-10 WITH IE2 MOTOR - all VFD inbuilt PLC IP55 panel - MS Galvanised skid mounted with 200 LTR. Pressure tank

1

-

-

... More
Supply, installation, testing and commissioning of continuous duty submersible centrifugal non-clogging drainage pumps complete with 3 phase motor with all necessary protection and mechanical seal etc. Vendor to submit proposed pump model with duty curve. (for basement storm sump & ugr sump pump) Flow rate : 5 LPS ( 1W+1S) Head : 15_Mts Solid Handling : 20 MM Location : underground pump room Purpose : dewatering sump MOC : CI body / impeller & shaft Cost to be inclusive of ready made electro – galvanized MS lifting chain, class C GI pipe header complete with discharge manifold, flanges, tee, elbow etc. complete including GI pipe upto the top of sump and including GI union. The installation shall be complete with all necessary indigenous accessories as required to complete the installation. Level Controller comprising of Level Switches, Float Switch, Solenoid Valve, Solenoid Valve Panel, Cables etc.

2

-

-

... More
Providing, Fixing, Testing & Commissioning of Spray Pou-up Sprinkler,nozzles,hose, piping, valves, pumps for 1000 sq.m. landscape area including all required necessary fittings, labours all taxes if any etc. (item shall include all required irrigation plumbing work material & labour cost)

1

-

-

... More
Supplying, installing and commissioning automatic organic waste composting machine for 150KG/day and including all required accessories

1

-

-

... More
Providing & fixing Stainless steel plain grating over Nahani trap for urinals with all necessary cutting, filling, fixing & making good the services, etc,complete. Plain cover for urinals - Top grating size in mm - 100 x 100

10

-

-

... More
Supply, Installation, Testing & commissioning of S.S.Vertical grating around at the entrance of RWP on terrace with all necessary fittings, making proper connection with cement solvent joints, cutting chase / hole in wall and bringing the same in proper condition and shape after placing the grating in right position complete as required. with material and labour etc. completeas per the direction of project engineer. 160mm

40

-

-

... More
Providing and fixing factory made precast RCC perforated drain covers with frame, having concrete of strength not less than M-25, including providing perforations, complete, all as per direction of Engineerin- charge Size1000 x 300x50 mm

300

-

-

... More
Earthwork in excavation in foundation pipeline trenches, drain in saturated soil upto a depth of 0.6m lift upto 1.5 m including shoring strutting, pumping/ bailing out water ,stacking the excavated soil not more than 5m clear from the edge of the excavation and returning the stacked soil in 0.15 m layers when required into plinth sides of foundation, etc. consolidating each deposited layer by ramming and watering and disposing of all surplus excavated soil within a lead upto 20 m.

1159.5

-

-

... More
Refilling the pipeline/foundation trenches plinth sides, foundation etc. with available excavated earth in layers not exceeding 20 cm depth consolidating each layer ramming and watering lead upto 50 M and all lifts and disposal of surplus earth as directed by Engineer in Charge.

930

-

-

... More
Supplying, installation, testing & commissioning drain channel 150mm wide (30mm thick) for entrance, channel with suitable grating in flooring, pipe connection to nearestchamber including required accessories & consumables etc. complete as direction of engineer in charge. manufacturer guidelines to be reffered for installation process.

50

-

-

... More
INTERIOR WORKS

-

-

-

... More
OFFICE TABLE (TABLE SIZE: 1800mm(L) X 750mm(D) X 750mm(HT) SIDE TABLE SIZE : 900mm(L) X 450(D) X 700(HT) Supplying & installing in position main table of approved make, colour & size with top made up of 25mm thick exterior grade prelaminated particle board with 2mm thick PVC edge banding on all sides & supported on Gable ends/sides made out of 25mm thick prelaminated particle board & Modesty panels in 18mm thick prelaminated particle board.Gable ends & modesty panel exposed edges shall be finished in 2mm thick PVC edge banding & sealed edges shall be in 0.8mm thick PVC edge banding. Wire routing/ wire management shall be provided on main table or side table as specified. Table shall have independent Mild steel powder coated CPU trolley, wire manager & MS powder coated key board tray of standard size. The keyboard tray shall accommodate mouse pad. The side table of approved size shall have top made up 25mm thick exterior grade prelaminated particle board top with 2mm PVC edge banding & supported with storage cabinet below in 18mm thick prelaminated particle board, back sheet of 9mm thick prelaminated particle board & skirting of 75mm height. Cabinet shall have two equal size shutters in 18mm thick prelaminated particle board with 2mm thick PVC edge banding & fixed with S.S. brush finish brass hinges & shall be provided with full length aluminium G profile handles /4'' S.S.304 grade brush finish handles, premium lock, & one shelf in centre fixed on shelf button. The pedestal unit of size 350mm(L)X450mm(W)X550mm(H) shall have top made up of 25 mm thick prelaminated particle board & sides in 18 mm thick prelaminated particle board and 75 mm height skirting with 2mm thick PVC edge banding on exposed edges 0.8 mm thick PVC edge banding on sealed edges. The pedestal shall have three equal size drawers with front fascia having central locking system & full length aluminium G profile handles/ 4"SS 304 grade brush finish handles ,roller slide mechanism and casters for added mobility. All exposed edges shall have 2mm thick PVC edge banding and sealed edges shall have 0.8mm thick PVC edge banding. All material shall be of approved make. Modular furniture shall confirm to BIFMA & FIRA standards. All works complete as per the drawing / Image, technical specification and direction of the Engineer .

1

-

-

... More
4 SEATER SQUARE TABLES (TABLE SIZE: 900mm(L) X 900mm(D) X 750mm(HT) BUSSINESS LOUNGE & C.O.E TABLES Supplying and installing in position lounge table of approved make, colour and size made up of 19mm thick Marine BWP (boiling water proof) plywood and finished in 10mm thk 100% acrylic UV grade solid surfacee. The understructure shall be made up of PVD coated stainless steel 304 grade base/ vertical supports as per design. All material shall be of approved make. All works complete as per the drawing/ Image, technical specification and direction of the Engineer.

3

-

-

... More
CENTER TABLES (TABLE SIZE: 900mm(L)/900mm(dia) X 900mm(D) X 600mm(HT) (T4) BUSSINESS LOUNGE & C.O.E TABLES Supplying and installing in position lounge table of approved make, colour and size made up of 19mm thick Marine BWP (boiling water proof) plywood and finished in 10mm thk 100% acrylic UV grade solid surfacee. The understructure shall be made up of PVD coated stainless steel 304 grade base/ vertical supports as per design. All material shall be of approved make. All works complete as per the drawing/ Image, technical specification and direction of the Engineer.

6

-

-

... More
CENTER TABLES (TABLE SIZE: 750mm(L)/900mm(dia) X 900mm(D) X 600mm(HT) (BUSSINESS LOUNGE & C.O.E TABLES Supplying and installing in position lounge table of approved make, colour and size made up of 19mm thick Marine BWP (boiling water proof) plywood and finished in 10mm thk 100% acrylic UV grade solid surfacee. The understructure shall be made up of PVD coated stainless steel 304 grade base/ vertical supports as per design. All material shall be of approved make. All works complete as per the drawing/ Image, technical specification and direction of the Engineer.

2

-

-

... More
CORNER TABLES TABLE SIZE: 600mm(L)/600mm(dia) X 600mm(D) X 450mm(HT) (T5) BUSSINESS LOUNGE & C.O.E TABLES Supplying and installing in position lounge table of approved make, colour and size made up of 19mm thick Marine BWP (boiling water proof) plywood and finished in 10mm thk 100% acrylic UV grade solid surfacee. The understructure shall be made up of PVD coated stainless steel 304 grade base/ vertical supports as per design. All material shall be of approved make. All works complete as per the drawing/ Image, technical specification and direction of the Engineer.

5

-

-

... More
SQUARE TABLES - 4 SEATER (TABLE SIZE:900mm(L) X 900mm(D) X 750mm(HT) Supplying & installing in position cafetaria tables with table top made up of particle board conforming to IS:12823 interior grade with prelaminated finish. Top shall be 25mm thick with 2mm PVC edge banding with enhanced scratch resistance with understructure of Mild steel powder coated sections of 2 mm thick as per approved design.Understructure shall be fitted to top by stainless steel machine screws. The table shall have a plastic glide fixed at the understructure to prevent the damage of table while stacking complete with all hardwares accessories. All material shall be of approved make. All works complete as per the drawing/ Image, technical specification and direction of the Engineer. (Refer drawing number – UM-IN-201 to UM-IN-205)

45

-

-

... More
RECTANGLE TABLES - 4 SEATER (TABLE SIZE:1400mm(L) X 750mm(D) X 750mm(HT) Supplying & installing in position cafetaria tables with table top made up of particle board conforming to IS:12823 interior grade with prelaminated finish. Top shall be 25mm thick with 2mm PVC edge banding with enhanced scratch resistance with understructure of Mild steel powder coated sections of 2 mm thick as per approved design.Understructure shall be fitted to top by stainless steel machine screws. The table shall have a plastic glide fixed at the understructure to prevent the damage of table while stacking complete with all hardwares accessories. All material shall be of approved make. All works complete as per the drawing/ Image, technical specification and direction of the Engineer. (Refer drawing number – UM-IN-201 to UM-IN-205)

6

-

-

... More
STORAGE UNIT (SIZE: 900mm(L)X 450mm(D) X 750mm(HT) Supplying and installing in position storage unit of approved make, colour and size with top made up of 25 mm thick exterior pre laminated particle board & having storage body made up of 18mm thick exterior grade pre laminated particle board, back of the unit made up of 9 mm thick exterior particle board with 75 mm height skirting. All the exposed edges are in 2 mm thick PVC (Polyvinyl Chloride) edge banding & sealed edges are in 0.8 mm thick PVC (Polyvinyl Chloride) edge banding. Equal size shutters (upto 500 mm wide) fixed with stainless steel brush finish brass hinges of 38 mm, handles , premium lock to be provided and one shelf in centre fixed on shelf button. Both made up of 18 mm thick pre laminated particle board with 2 mm thick PVC (Polyvinyl Chloride) edge banding on exposed sides & sealed edges in 0.8mm thick PVC (Polyvinyl Chloride) edge banding sizes shall be cross checked on site as per site measurements at the time of execution.All material shall be of approved make.All complete as per the drawing / Image, technical specification and direction of the Engineer. (Refer drawing number – UM-IN-201 to UM-IN-205

6

-

-

... More
4 SEATER LINEAR MODULE (WS1) TABLE SIZE: 1200mm(L) X 600mm(D) X 750mm(HT) LINEAR WORKSTATION Providing, fabricating and fixing in position Panel based modular cubicle type workstations which Includes Partition, work surface with side table & MS powder coated CPU trolley. Work surface shall be in 25mm thick exterior grade prelaminated Particle board with 2mm thk PVC imported edge banding tape. The bottom surface of the table shall also be laminated. The worktops shall be supported on MS powder coated frame & legs. Modesty panel shall be in MS powder coated panels/18mm prelam panels as per design. The worktops shall be provided with PVC wire manager for cabling. Storage: Side storage shall have 1 module of drawers and 2 modules of sliding shutter cabinet .The top shall be in 25mm thick pre laminated particle board. The shutters & drawers shall be made of 18mm thick pre laminated particle board. All the exposed edges shall be sealed with 2mm thick PVC Imported edge banding. Cabinet shall be provided with single shelf and single shutter fixed on sliding mechanism. The drawer unit shall consist of 2 box drawer and 1 file drawer. The drawer box shall be fitted with roller Slide.The drawer unit shall be provided with central locking system, where in the three drawer shall be locked with one key. 4"SS 304 grade brush finish handles shall be provided. Cubicle Partition: Partition thickness shall be 75mm with the inside gap between two tiles shall be approximately 50mm for higher wire carrying capacity.Frame Horizontals shall be of 1mm thick CRCA sheets & the verticals shall be of Aluminium Extrusions of 1.5mm thick Frame and shall be inline with the Top trims & end trims.. All the frames shall be duly powder coated. The partitions shall be provided with leveling bolts / screws to take care of undulations in the floor level. Panel Tiles: The fabric tile panels shall be Constructed out of 4mm thick Medium Density Fiber Board (MDF) and covered with Fabric of choice. Wire management: Internal Concealed Raceways shall be provided below work surface with switchboard arrangement for Power & Data along with PVC Wire manager with Grommet / scallops & Individual Raceway arrangement for Data/ Power cable. CPU Trolley & Keyboard tray: CPU trolley shall be made from 1mm Thick CRCA steel sheet. The trolley shall be mounted on lockable castors. The keyboard tray shall be MS powder coated & shall be fixed on telescopic channels & have provision for mouse pad. All material shall be of approved make. All works complete as per the drawing/ Image, technical specification and direction of the Engineer . (Refer drawing number – UM-IN-201 to UM-IN-205)

6

-

-

... More
3 MODULE L SHAPED WORKSTATION (WS3) TABLE SIZE: 1500mm(L) X 1500mm(D) X 750mm(HT) Providing, fabricating and fixing in position Panel based modular cubicle type workstations which Includes Partition, work surface with side table & MS powder coated CPU trolley. Work surface shall be in 25mm thick exterior grade prelaminated Particle board with 2mm thk PVC imported edge banding tape. The bottom surface of the table shall also be laminated. The worktops shall be supported on MS powder coated frame & legs. Modesty panel shall be in MS powder coated panels/18mm prelam panels as per design. The worktops shall be provided with PVC wire manager for cabling. Storage: Side storage shall have 1 module of drawers and 2 modules of sliding shutter cabinet .The top shall be in 25mm thick pre laminated particle board. The shutters & drawers shall be made of 18mm thick pre laminated particle board. All the exposed edges shall be sealed with 2mm thick PVC Imported edge banding. Cabinet shall be provided with single shelf and single shutter fixed on sliding mechanism. The drawer unit shall consist of 2 box drawer and 1 file drawer. The drawer box shall be fitted with roller Slide.The drawer unit shall be provided with central locking system, where in the three drawer shall be locked with one key. 4"SS 304 grade brush finish handles shall be provided. Cubicle Partition: Partition thickness shall be 75mm with the inside gap between two tiles shall be approximately 50mm for higher wire carrying capacity.Frame Horizontals shall be of 1mm thick CRCA sheets & the verticals shall be of Aluminium Extrusions of 1.5mm thick Frame and shall be inline with the Top trims & end trims.. All the frames shall be duly powder coated. The partitions shall be provided with leveling bolts / screws to take care of undulations in the floor level. Panel Tiles: The fabric tile panels shall be Constructed out of 4mm thick Medium Density Fiber Board (MDF) and covered with Fabric of choice. Wire management: Internal Concealed Raceways shall be provided below work surface with switchboard arrangement for Power & Data along with PVC Wire manager with Grommet / scallops & Individual Raceway arrangement for Data/ Power cable. CPU Trolley & Keyboard tray: CPU trolley shall be made from 1mm Thick CRCA steel sheet. The trolley shall be mounted on lockable castors. The keyboard tray shall be MS powder coated & shall be fixed on telescopic channels & have provision for mouse pad. All material shall be of approved make. All works complete as per the drawing/ Image, technical specification and direction of the Engineer . (Refer drawing number – UM-IN-201 to UM-IN-205)

2

-

-

... More
CABIN CHAIRS (C1) Supplying and placing in position armed revolving high back chairs of approved make and colour and BIFMA (The Business & Institutional furniture manufactures association) compliant. Chair shall have cushioned seat and back upholstered with good quality fabric of approved color. The seat and back shall be made of moulded foam with integrated lumber support having contoured shape at seat back for better comfort. The seat and back shall be made up of 12 ±0.1mm. thick hot-pressed plywood upholstered with moulded foam and fabric. The HR polyurethane foam shall be moulded with density= 42±2 kg/m3. The chair shall have BIFMA compliant Class 3 gas lift for seat height adjustment with an adjustment stroke of 100mm. The chair shall be provided with Centre Tilt mechnism with upright position locking, 360 degree revolution, Tilt tension adjustment, Nylon Castors along with Nylon Star Base. The twin wheel castors shall be injection moulded in Black Nylon. The chair shall have PP adjustable armrest with position locking. Overall Dimension: 590 (W) X 745 (D) X ( 1050-1145 )H. All material shall be of approved make. All works complete as per the drawing/ Image, technical specification and direction of the Engineer (Refer drawing number – UM-IN-201 to UM-IN-205)

1

-

-

... More
STAFF CHAIRS (C2) Supplying and placing in position armed revolving mid back chairs of approved make and colour and BIFMA (The Business & Institutional furniture manufactures association) compliant. Chair shall have cushioned seat and back upholstered with good quality fabric of approved color. The seat and back shall be made of moulded foam with integrated lumber support having contoured shape at seat back for better comfort. The seat and back shall be made up of 12 ±0.1mm. thick hot-pressed plywood upholstered with moulded foam and fabric. The HR polyurethane foam shall be moulded with density= 42±2 kg/m3. The chair shall have BIFMA compliant Class 3 gas lift for seat height adjustment with an adjustment stroke of 100mm. The chair shall be provided with Centre Tilt mechnism with upright position locking, 360 degree revolution, Tilt tension adjustment, Nylon Castors along with Nylon Star Base. The twin wheel castors shall be injection moulded in Black Nylon. The chair shall have PP adjustable armrest with position locking. Overall Dimension: 590 (W) X 670 (D) X ( 985-1080 ) H. All material shall be of approved make. All works complete as per the drawing/ Image, technical specification and direction of the Engineer (Refer drawing number – UM-IN-201 to UM-IN-205)

8

-

-

... More
VISITOR CHAIRS (C3) Supplying and placing in position armed revolving low back chairs of approved make and colour and BIFMA (The Business & Institutional furniture manufactures association) compliant. Chair shall Supply and installation of a Low Back Chair having cushioned seat and back upholstered with good quality fabric of approved color. The seat and back shall be made of moulded foam with integrated lumber support having contoured shape at seat back for better comfort. The seat and back shall be made up of 12 ±0.1mm. thick hot-pressed plywood upholstered with moulded foam and fabric. The HR polyurethane foam shall be moulded with density= 42±2 kg/m3. The chair shall have BIFMA compliant Class 3 gas lift for seat height adjustment with an adjustment stroke of 100mm. The chair shall be provided with Centre Tilt mechnism with upright position locking, 360 degree revolution, Tilt tension adjustment, Nylon Castors along with Nylon Star Base. The twin wheel castors shall be injection moulded in Black Nylon. The chair shall have PP adjustable armrest with position locking. Overall Dimension: 590 (W) X 615 (D) X ( 935-1030 ) H. All material shall be of approved make. All works complete as per the drawing/ Image, technical specification and direction of the Engineer. (Refer drawing number – UM-IN-201 to UM-IN-205)

7

-

-

... More
FOOD COURT CHAIRS (C4) Supplying and Placing in position Chairs of approved make and colour moulded in polypropylene. The seat and back shall be of one piece injection. The tubular understructure shall be fabricated SS 202 grade tube welded together with SS connecting rods. The understructure shall be provided with black PP injection moulded ferrules. All material shall be of approved make. All works complete as per the drawing/ Image, technical specification and direction of the Engineer. (Refer drawing number – UM-IN-201 to UM-IN-205)

176

-

-

... More
BUSINESS LOUNGE CHAIRS (C6) Supplying & placing in position study chair of approved design, colour and size having solid frame structure with inner frame made of kiln chemical treated approved high quality wood. The seat cusion shall be made of 4" multi layered foam of density 32D and HD with polyester polyfill outer layer of 180 gsm to keep the upholstery wrinkle free & soft. The thread used shall be nylon bonded to provide lasting stitch strength. The backrest shall be made of 2" foam of 23D with polyester polyfill outer layer of 180 gsm to keep the upholstery wrinkle free & soft. The thread used shall be nylon bonded to provide lasting stitch strength.The outer finish shall be of superior quality leatherette (upto Rs. 1200 per metre) stitched with nylon bonded thread. The legs shall be prong type of s.s 304 grade sections. All material shall be of approved make. All works complete as per the drawing/ Image, technical specification and direction of the Engineer.(Seat Height - 410 - 450mm mm). (Refer drawing number – UM-IN-201 to UM-IN-205)

12

-

-

... More
BUSINESS LOUNGE - SOFA CHAIRS (C7) Supplying & placing in position lounge chair of approved design, colour and size having solid frame structure with inner frame made of kiln chemical treated approved high quality wood. The seat cusion shall be made of 4" multi layered foam of density 32D and HD with polyester polyfill outer layer of 180 gsm to keep the upholstery wrinkle free & soft. The thread used shall be nylon bonded to provide lasting stitch strength. The backrest shall be made of 2" foam of 23D with polyester polyfill outer layer of 180 gsm to keep the upholstery wrinkle free & soft. The thread used shall be nylon bonded to provide lasting stitch strength.The outer finish shall be of superior quality leatherette (upto Rs. 1200 per metre) stitched with nylon bonded thread. The legs shall be prong type of s.s 304 grade sections. All material shall be of approved make. All works complete as per the drawing/ Image, technical specification and direction of the Engineer.(Seat Height - 410 - 450mm mm). (Refer drawing number –UM-IN-201 to UM-IN-205)

4

-

-

... More
SEMINAR HALL - CHAIRS (C8) Supplying and placing in position Training flap type chairs having Chair Seat & back in PP (polypropylene) with cushion on seat. The Frame shall be in M. S powder coating with eye shape pipe of 30mm x 15mm x 16g, PU cladding on Arms , Writing Tablet in both side prelaminated particle board with all side edge banding.All material shall be of approved make. All works complete as per the drawing/ Image, technical specification and direction of the Engineer. (Refer drawing number – UM-IN-201 to UM-IN-205)

572

-

-

... More
SLATTED BENCH Supplying and installing in position bench of approved make, design and size with top made up of WPC (wood plastic composite) slats & framework & legs in Stainless steel 304 grade rectangular sections of size 50mm x 25mm x 2 mm as per approved design. All material shall be of approved make. All works complete as per the drawing / Image, technical specification and direction of the Engineer. (Refer drawing number –UM-IN-201 to UM-IN-205) BENCH (SB1) SIZE: 1800(L) X 450(D) X 450(HT)

4

-

-

... More
3 SEATER SOFA (LOBBY/ WAITNG) (S1) SOFA- (ADMIN) Supplying & placing in position sofa of approved design, colour and size having solid frame structure with inner frame made of kiln chemical treated approved high quality wood. The seat cusion shall be made of 7" multi layered foam of density 32D and HD with polyester polyfill outer layer of 180 gsm to keep the upholstery wrinkle free & soft. The thread used shall be nylon bonded to provide lasting stitch strength. The backrest shall be made of 4 inch foam of 23D with polyester polyfill outer layer of 180 gsm to keep the upholstery wrinkle free & soft. The seating cushions shall have 2 inches of elastic webbing of 250 gsm with diagonal weave. The thread used shall be nylon bonded to provide lasting stitch strength. The outer finish shall be of superior quality leatherette (upto Rs. 550 per metre) stitched with nylon bonded thread. The legs and frame shall be of s.s 304 grade tubular section and 2 mm thickness with rubber gasket. All material shall be of approved make. All works complete as per the drawing/ Image, technical specification and direction of the Engineer.(Seat Height: 410 - 45mm) (Refer drawing number – UM-IN-201 to UM-IN-205)

2

-

-

... More
1 SEATER SOFA ( BUSINESS LOUNGE ) (S2) SOFA ( BUSINESS LOUNGE) (S2,S3,S4) Supplying & placing in position sofa of approved design, colour and size having solid frame structure with inner frame made of kiln chemical treated approved high quality wood. The seat cusion shall be made of 7" multi layered foam of density 32D and HD with polyester polyfill outer layer of 180 gsm to keep the upholstery wrinkle free & soft. The thread used shall be nylon bonded to provide lasting stitch strength. The backrest shall be made of foam of 23D with polyester polyfill outer layer of 180 gsm to keep the upholstery wrinkle free & soft. The seating cushions shall have elastic webbing of 250 gsm with diagonal weave. The thread used shall be nylon bonded to provide lasting stitch strength.The outer finish shall be of superior quality leatherette (upto Rs. 700 per metre) stitched with nylon bonded thread. The legs shall be of PVD coated SS 304 grade tubular section of height 100mm and 2 mm thickness with rubber gasket. All material shall be of approved make. All works complete as per the drawing/ Image, technical specification and direction of the Engineer.(Seat Height - 410 mm) (Refer drawing number – UM-IN-201 to UM-IN-205)

4

-

-

... More
2 SEATER SOFA ( BUSINESS LOUNGE ) (S3) SOFA ( BUSINESS LOUNGE) (S2,S3,S4) Supplying & placing in position sofa of approved design, colour and size having solid frame structure with inner frame made of kiln chemical treated approved high quality wood. The seat cusion shall be made of 7" multi layered foam of density 32D and HD with polyester polyfill outer layer of 180 gsm to keep the upholstery wrinkle free & soft. The thread used shall be nylon bonded to provide lasting stitch strength. The backrest shall be made of foam of 23D with polyester polyfill outer layer of 180 gsm to keep the upholstery wrinkle free & soft. The seating cushions shall have elastic webbing of 250 gsm with diagonal weave. The thread used shall be nylon bonded to provide lasting stitch strength.The outer finish shall be of superior quality leatherette (upto Rs. 700 per metre) stitched with nylon bonded thread. The legs shall be of PVD coated SS 304 grade tubular section of height 100mm and 2 mm thickness with rubber gasket. All material shall be of approved make. All works complete as per the drawing/ Image, technical specification and direction of the Engineer.(Seat Height - 410 mm) (Refer drawing number – UM-IN-201 to UM-IN-205)

8

-

-

... More
HELP DESK (B1) SIZE: 5300mm(L) X 700mm(D) X1100mm(HT) Providing & fixing in position help desk in 19mm thick Marine BWP (boiling water proof) plywood and finished in 12mm thk 100% acrylic UV grade solid surface for ledge, fascia box and top and 4mm thick veneer externally for remaining surfaces and 1mm thick laminate internally. Table shall be provided with keyboard trays, fixed drawer and cabinets. Drawer shall be in 19 mm thick plywood front fascia, 12mm ply for sides and back, with 6mm ply for base & finished with 4mm thick veneer externally and 1mm thick laminate internally and shall be supported on telescopic side mounted channels. The drawer unit shall have locking arrangement & PVD coated SS 304 grade selected handles (100mm) Cabinets shall have shutters in 19mm thick ply fixed on SS. brush finished brass hinges and single shelf each in 19mm ply & finished with 1mm thick laminate along sides and edges & fixed on stainless steel finished shelf buttons. Shutters shall be fixed with heavy duty brushed finish handles (100 mm). All internal exposed edges to be finished with 1mm laminate or PVC edge banding tape. All external exposed edges shall be finished with teak wood lipping with 3 coats or more of melamine polish to match the shade of veneer. All works shall be complete with necessary labour, hardware, cleaning, placing in position etc. Provision shall be made for wire management to take care of basic wiring requirement for providing power data- voice switches on a modular switch plate.Table shall have independent wire manager of standard size, Stainless steel finished hardware. The rate shall include cleaning, placing in position, etc. complete. All material shall be of approved make. All works complete as per the drawing, specification and direction of the Engineer. (Refer drawing number – UM-IN-201 to UM-IN-205, UM-IN-601)

1

-

-

... More
COUNTER IN BUSINESS LOUNGE (B2) SIZE: 3600 mm(L) X 700mm(D) X 1100 mm(HT) Providing & fixing in position help desk in 19mm thick Marine BWP (boiling water proof) plywood and finished in 12mm thk 100% acrylic UV grade solid surface for ledge, fascia box and top and 4mm thick veneer externally for remaining surfaces and 1mm thick laminate internally. Table shall be provided with keyboard trays, fixed drawer and cabinets. Drawer shall be in 19 mm thick plywood front fascia, 12mm ply for sides and back, with 6mm ply for base & finished with 4mm thick veneer externally and 1mm thick laminate internally and shall be supported on telescopic side mounted channels. The drawer unit shall have locking arrangement & PVD coated SS 304 grade selected handles (100mm) Cabinets shall have shutters in 19mm thick ply fixed on SS. brush finished brass hinges and single shelf each in 19mm ply & finished with 1mm thick laminate along sides and edges & fixed on stainless steel finished shelf buttons. Shutters shall be fixed with heavy duty brushed finish handles (100 mm). All internal exposed edges to be finished with 1mm laminate or PVC edge banding tape. All external exposed edges shall be finished with teak wood lipping with 3 coats or more of melamine polish to match the shade of veneer. All works shall be complete with necessary labour, hardware, cleaning, placing in position etc. Provision shall be made for wire management to take care of basic wiring requirement for providing power data- voice switches on a modular switch plate.Table shall have independent wire manager of standard size, Stainless steel finished hardware. The rate shall include cleaning, placing in position, etc. complete. All material shall be of approved make. All works complete as per the drawing, specification and direction of the Engineer. (Refer drawing number – UM-IN-201 to UM-IN-205, UM-IN-602)

1

-

-

... More
STORAGE UNIT -LAMINATE FINISH (450mm depth) (B3) Providing & fixing in position storage in 19 mm thick Marine BWP (boiling water proof) plywood & finished with 1mm thick approved laminate externally and 1mm thick laminate internally. Back sheet shall be in 8mm plywood & cabinets with shutters fixed on SS. brush finished brass hinges and shelf in 19mm ply & finished with 1mm thick internal laminate on both sides & fixed on stainless steel finished shelf buttons. Cabinet shutters shall be fixed with heavy duty SS 304 brushed finish handles (100 mm) . All exposed edges of plywood shall be finished with 1mm thick laminate or PVC edge banding tape and second class teak wood lipping where ever necessary with 2 to 3 coats of melamine polish to match the shade of laminate & complete with necessary labour, hardware, cleaning, placing in position etc. complete. All material shall be of approved make. All works complete as per the drawing, specification and direction of the Engineer. (Refer drawing number – UM-IN-201 to UM-IN-205, UM-IN-603)

18.9

-

-

... More
LEDGE (300mm depth) - LAMINATE FINISH (B5) Providing & fixing in position 300mm depth ledge in 19mm thick Marine BWP (boiling water proof) plywood & finished with 1mm thick laminate on all sides with ledge thickness of 50mm in ply fascia. The ledge shall be fixed on wall/column/partition etc. with back supports and intermediate supports in ply. The rate shall include cleaning, placing in position, etc. complete. All material shall be of approved make. All works complete as per the drawing, specification and direction of the Engineer. (Refer drawing number – UM-IN-201 to UM-IN-205, UM-IN-605

10

-

-

... More
LAMINATE PARTITION (B8) Providing & fixing in position laminate finish partition having aluminium framework (approved make) of size 65mm x 38 mm tubular frame ,18 gauge, having grid spacing at 600mmx600mm centre to centre both ways & covered with 12 mm thick Marine BWP (boiling water proof) plywood on all sides of framework & finished with 1mm thick laminate of approved color and texture. The framework shall be properly screwed to the walls/beams/columns/ floor and plywood shall be screwed to the framework. The space between the framework grid shall be filled with glass wool having density of 48 Kg/ Cum for sound insulation. Provision shall be made for necessary cutouts for services such as wire management etc. as per design including all necessary hardware & accessories, grooves, adhesives, cutting & making good the original surfaces on completion. All material shall be of approved make. All works complete as per the drawing, specification and direction of the Engineer (Refer drawing number – UM-IN-201 to UM-IN-205, UM-IN-608)

62.5

-

-

... More
SINGLE SHUTTER GLASS DOOR (B9) (SIZE - 900mm(L) x2400mm(HT) Providing & fixing in position single shutter glass door using 12 mm thick toughened glass having etching pattern/3M film as approved & fixed using heavy duty double action floor spring, SS 304 brush finish solid top patch with pivot and provided with SS 304 grade matt finish handle, SS brush finish solid bottom patch lock .All material shall be of approved make. All works complete as per the drawing, specification and direction of the Engineer. (Refer drawing number – UM-IN-201 to UM-IN-205, UM-IN-609)

6

-

-

... More
DOUBLE SHUTTER GLASS DOORS (B10a, B10b) Providing & fixing in position double shutter glass door using 12 mm thick toughened glass having etching pattern/3M film as approved & fixed using heavy duty double action floor spring, SS brush finish solid top patch with pivot and provided with SS 304 grade matt finish handle, SS brush finish solid bottom patch lock .All material shall be of approved make. All works complete as per the drawing, specification and direction of the Engineer. (Refer drawing number – UM-IN-201 to UM-IN-205, UM-IN-610a, UM-IN-610b) (SIZE - 1500mm(L) x2400mm(HT)

24

-

-

... More
SINGLE SHUTTER FLUSH DOOR (B11) (SIZE - 900mm(L) x2400mm(HT) Providing & fixing in position door made with solid core waterproof flush door shutter of 35mm thick & finished with 1mm thick laminate of approved colour & texture on both sides & second class Indian teak wood lipping of size 38x12mm on edges of shutter. Door shall be fixed using SS. brush finished brass butt hinges & provided with a surface mounted hydraulic door closer, SS matt finish concealed mortise lock case with lever handle, profile thumb turn cylinder (with key outside & thumb turn inside) with key hole, PVC door buffer & SS brush finish door stopper. All exposed second class Indian teak wood lipping & frame shall be finished with 2 to 3 coats of melamine polish (Matt/Gloss) to match the colour/ shade of the laminate including final coat of buffing till the required finish is achieved. All material shall be of approved make. All works complete as per the drawing, specification and direction of the Engineer. (Refer drawing number – UM-IN-201 to UM-IN-205, UM-IN-611)

24

-

-

... More
MODULAR TOILET CUBICLES (B12) Supplying and Installing in position rest room cubicles in 12mm thick solid compact laminate of approved shade and make having partition of 12mm thickness, height upto 2.1 mts from finished floor, including all necessary accessories like "U" Channels, Top Rail, adjustable foots, Floor anchors etc. complete. All material shall be of approved make. All works complete as per the drawing, specification and direction of the Engineer (Refer drawing number – UM-IN-201 to UM-IN-205, UM-IN-612)

90

-

-

... More
VENEER FINISH PANELING (B13) Providing & fixing in position paneling in 12mm thick Marine BWP (boiling water proof) plywood finished with 4mm thk veneer as per design and having horizontal & vertical framework at 600mm c/c of maximum depth 200mm in 19mm thick double ply fixed on wall /beam /column /slab/partition wherever required. Cove for indirect lighting shall be made as per design. All internal exposed edges to be finished with 1mm laminate or PVC edge banding tape. All external exposed edges shall be finished with teak wood lipping with 3 coats or more of melamine polish to match the shade of veneer. All works shall be complete with necessary labour, hardware, cleaning, placing in position etc. All material shall be of approved make. All works complete as per the drawing, specification and direction of the Engineer. (Refer drawing number – UM-IN-201 to UM-IN-205, UM-IN-613)

49

-

-

... More
LAMINATE FINISH PANELING (B14) Providing & fixing in position paneling in 12mm thick Marine BWP (boiling water proof) plywood finished with 1mm thk laminate as per design and having horizontal & vertical framework at 600mm c/c of maximum depth 200mm in 19mm thick double ply fixed on wall /beam /column /slab/partition wherever required.Cove for indirect lighting shall be made as per design. All internal exposed edges shall be finished with 1mm laminate or PVC edge banding tape. All external exposed edges shall be finished with teak wood lipping with 3 coats or more of melamine polish to match the shade of laminate. All works shall be complete with necessary labour, hardware, cleaning, placing in position etc. All material shall be of approved make. All works complete as per the drawing, specification and direction of the Engineer. (Refer drawing number – UM-IN-201 to UM-IN-205, UM-IN-614)

147.44

-

-

... More
ACOUSTIC BOARD PANELING (B15) Providing & fixing in position paneling in 12mm thick Marine BWP (boiling water proof) plywood finished with 10mm thick acoustical panels of approved colour and design. Framework for panelling shall be in horizontal & vertical framework at 600mm c/c of depth upto 100mm in 19mm thick double ply fixed on wall /beam /column /slab/partition wherever required. Acoustic board panels shall be in 9-10mm thickness polyester fibre board (1900/200GSM) of size 1.22x2.44mm. The boards shall be laser cut to required size & shape as per design and shall be pasted onto the plywood surface with required adhesive. The boards shall have good acoustic performance and shall be resistant to humdity & moisture. The boards shall be of required color shade and may be custom printed if required. All works shall be complete including all necessary labour, hardware & accessories, grooves, adhesives, cutting & making good the original surfaces etc. All material shall be of approved make. Measurements shall be calculated of as laid area.All works complete as per the drawing, specification and direction of the Engineer. (Refer drawing number – UM-IN-201 to UM-IN-205, UM-IN-615)

674

-

-

... More
GYPSUM PLASTERBOARD FINISH PANELLING (B16) Providing & fixing in position paneling in 19 mm and 12mm thick Marine BWP (boiling water proof) plywood finished with 12mm thk gypsum plasterboard as per design and having horizontal & vertical framework at 600mm c/c of necessary depth in 19mm thick double ply fixed on wall /beam /column /slab wherever required. All joints shall be finished using gypsum jointing tape. All works shall complete with necessary labour, hardware, cleaning, placing in position etc. All material shall be of approved make. All works complete as per the drawing, specification and direction of the Engineer. (Refer drawing number – UM-IN-201 to UM-IN-205, UM-IN-616)

33.54

-

-

... More
SOLID ACRYLIC SURFACE FINISH PANELLING (B17) Providing & fixing in position paneling in 19 mm and 12mm thick Marine BWP (boiling water proof) plywood finished with 12mm thk 100% acrylic UV grade solid surface of approved finish,texture,translucency,shade as per design and having horizontal & vertical framework at 600mm c/c of necessary depth upto 100mm in 19mm thick double ply fixed on wall /beam /column /slab/partition wherever required. Provision shall be made for necessary cutouts for services such as wire management etc. as per design including all necessary hardware & accessories, grooves, adhesives, cutting & making good the original surfaces on completion. All material shall be of approved make. All works complete as per the drawing, specification and direction of the Engineer. (Refer drawing number – UM-IN-201 to UM-IN-205, UM-IN-617

42

-

-

... More
PVD PROFILE INLAY (B18) Providing & fixing PVD coated SS T profile of 12mm width on wall/column/gypsum board partition/panelling by making groove of required size and pasting with necessary adhesive including labour. The rate shall include cleaning, placing in position, etc. complete. All material shall be of approved make. All works complete as per the drawing, specification and direction of the Engineer (Refer drawing number – UM-IN-201 to UM-IN-205, UM-IN-618)

10

-

-

... More
LASER CUT MDF SCREEN (B19) Providing & fixing in position 12mm thick MDF laser cut screen with frame in plywood of approved design. The frame shall be in 19mm thick marine BWP plywood box section and shall be finished with 6mm thick mdf on all sides. The laser cut screen shall be finished with approved shade of duco paint and shall be fixed to frame with wooden lipping. All mdf surfaces shall be finished with approved shade duco paint to achieve desired finish.All works shall be complete with necessary labour, hardware, cleaning, placing in position etc.All material shall be of approved make. All works complete as per the drawing, specification and direction of the Engineer. (Refer drawing number – UM-IN-201 to UM-IN-205, UM-IN-619)

5

-

-

... More
BENCH (B22) Providing & fixing in position seating bench in vertical frame work in 50mm x 50mm x 2.9mm thick mild steel powder coated sections, over which 50mm x 50mm x 2.9mm thick M.S. sections frame work with intermediate supports shall be be welded. Bench top shall be in 50mm x 25 mm x 2.9mm mild steel sections welded to M.S. section framework. All works shall be complete with hardware, cleaning, placing in position,labour etc. All material shall be of approved make. All works complete as per the drawing, specification and direction of the Engineer.(Refer drawing number – UM-IN-201 to UM-IN-205, UM-IN-622)

10

-

-

... More
PLATFORM (B23) Providing & fixing in position 200mm height wooden stage, having 38mm thick top, framework in 38x162mm matti wood planks at approximately 600mm x 600mm centre to centre placed both ways as shown in the drawing and all sides in 38 x 162 mm matti wood planks. Top shall be in 150mm wide & 38mm thick matti wood planks fixed with tongue and groove joint. All external exposed surfaces shall be finished with 3 or more coats of Melamine polish and french polish on underside/ internal surfaces complete with necessary labour and hardware, wire management etc complete as per drawing. All material shall be of approved make. All works complete as per the drawing, specification and direction of the Engineer. (Refer drawing number – UM-IN-201 to UM-IN-205, UM-IN-623)

1

-

-

... More
TRAP DOOR (B24) Providing & fixing in position 28mm thick trap door, frame work in 12 mm thick Marine BWP (boiling water proof) plywood frame work with 6mm plywood on both sides and finished with french polish internally and 4mm MDF with approved paint externally. Door shall be fixed on heavy duty SS. brush finished brass hinges on Aluminium framework of size 38mm x 65mm of thickness 18guage and height from 150 mm to1000 mm from slab bottom.All exposed edges shall be finished with second class teak wood lipping of required size with 2 to 3 coats of melamine polish to match the shade of wall/ceiling paint with necessary labour. Measurements will be considered for door size only. The rate shall include cleaning, placing in position, etc. complete. All material shall be of approved make. All works complete as per the drawing, specification and direction of the Engineer (Refer drawing number – UM-IN-201 to UM-IN-205, UM-IN-624)

40.5

-

-

... More
STAINLESS STEEL OPEN DUST BIN Providing and placing in position 16 gauge stainless steel dust bin of grade 304 cylindrical without cover . All material shall be of approved make. All complete as per the drawing, specification and direction of the Engineer. (Refer drawing number – UM-IN-501 to UM-IN-505)

50

-

-

... More
Stainless Steel Sliver Push Can Open Top Dustbin 350x800 Inch Providing and placing in position 16 gauge stainless steel dust bin of grade 304 cylindrical with cover (350mm dia x 800mm ht). All material shall be of approved make. All complete as per the drawing, specification and direction of the Engineer. (Refer drawing number – UM-IN-501 to UM-IN-505)

15

-

-

... More
PICTURE FRAME Supplying & fixing in position approved painting in digital printing on digital printing paper with synthetic frame & lamination. The details need to be as per the instructions of Engineer. All the materials shall be of approved make. All works complete as per the drawing, specification and direction of the Engineer. (Refer drawing number – UM-IN-501 to UM-IN-505) PICTURE FRAME (SIZE : 900 X 600 MM)

30

-

-

... More
ROLLER BLIND Providing & fixing in position roller blinds of approved fabric with aluminum extruded rail powder coated in white. Control unit to be made of high strength reinforced plastic. Roller tube to be anodised extruded tube of high strength alloy, including all necessary fittings and fixtures like idler, head rail, control unit, roller tube, bottom rail, operating chain, fixing brackets, clamps, etc. complete. Fabric shall be of approved make, color, length,texture. All the materials shall be of approved make. All works complete as per the drawing, technical specification and direction of the Engineer (Refer drawing number – UM-IN-501 to UM-IN-505)

651

-

-

... More
LAMINATED WOODEN FLOORING Providing and laying laminated wooden flooring with tongue and groove joints of approved make (armstrong/ ego ) laid as shown in drawing with  2mm thick inlay as approved laid on floor. necessary beading/ skirting required for completion including adhesive also includes in the item.the item also include levelling with plaster of paris if required & as per instruction of engineer in charge (Refer drawing number – UM-IN-501 to UM-IN-505)

140

-

-

... More
CARPET ROLL Providing and fixing of tufted loop pile carpet having gauge of 1/10, pile weight 350 gsm,thickness 4 mm fixed to the flooring with SR (Synthetic rubber) solution with 8mm U-foam underlay, including minor leveling with plaster of Paris. All the materials shall be of approved make. All works complete as per the drawing, specification and direction of the Engineer. (Refer drawing number – UM-IN-501 to UM-IN-505)

945

-

-

... More
VINYL ARTWORK Providing and fixing in position vinyl artwork of approved design, texture & make and pasted with glue/ special adhesive in line & level so as the joints are invisible. Vinyl used shall have matt lamination with eco solvent printing. All works complete as per the drawing, specification and direction of the Engineer. All the materials shall be of approved make. (Refer drawing number (Refer drawing number – UM-IN-501 to UM-IN-505)

202.5

-

-

... More
MIRROR - (SIZE :600MMX900MM) Providing & fixing in position mirror of approved design, make, colour and size in 6mm thickness with plain crystal edge polish on all sides and fixed using stainless steel mirror holding buttons/brackets, mirror back shall be flushed with wall & complete with necessary labour, hardware, cleaning, placing in position etc. complete. All material shall be of approved make. All works complete as per the drawing / Image, technical specification and direction of the Engineer. (Refer drawing number – UM-IN-501 to UM-IN-505)

60

-

-

... More
GLASS FROSTED FILM Providing & installing in position PVC frosted translucent glass film with self adhesive & laser cut to required design and pasted on glass. All material shall be of approved make. All works complete as per the drawing / Image, technical specification and direction of the Engineer. (Refer drawing number – UM-IN-501 to UM-IN-505)

125

-

-

... More
INTERNAL SIGNAGES (ACP) SIZE - 300mm (L) X150mm (HT) INTERNAL SIGNAGES SIZE (ACP) Providing and fixing in position signages made from 4 mm thick aluminium composite panel with computer cut lettering of specified height and width, self adhesive vinyl pasted on it to protect from peeling. The panel will be fixed on the door/wall with 12mm SS. stud /SS mirror screw arrangement /3m Tape or suspended from the ceiling by means of SS chain of 8mm dia with anchor fasteners complete as required. All material shall be of approved make. All works complete as per the drawing, specification and direction of the Engineer (Refer drawing number – UM-IN-501 to UM-IN-505)

15

-

-

... More
INTERNAL SIGNAGES (ACP) SIZE - 300mm (L) X150mm (HT) HANGING ON CHAIN INTERNAL SIGNAGES SIZE (ACP) Providing and fixing in position signages made from 4 mm thick aluminium composite panel with computer cut lettering of specified height and width, self adhesive vinyl pasted on it to protect from peeling. The panel will be fixed on the door/wall with 12mm SS. stud /SS mirror screw arrangement /3m Tape or suspended from the ceiling by means of SS chain of 8mm dia with anchor fasteners complete as required. All material shall be of approved make. All works complete as per the drawing, specification and direction of the Engineer (Refer drawing number – UM-IN-501 to UM-IN-505)

25

-

-

... More
INTERNAL SIGNAGES (ACP)SIZE - 900mm (L) X1200mm (HT) INTERNAL SIGNAGES SIZE (ACP) Providing and fixing in position signages made from 4 mm thick aluminium composite panel with computer cut lettering of specified height and width, self adhesive vinyl pasted on it to protect from peeling. The panel will be fixed on the door/wall with 12mm SS. stud /SS mirror screw arrangement /3m Tape or suspended from the ceiling by means of SS chain of 8mm dia with anchor fasteners complete as required. All material shall be of approved make. All works complete as per the drawing, specification and direction of the Engineer (Refer drawing number – UM-IN-501 to UM-IN-505)

15

-

-

... More
LETTERS OF BUILDING NAME (INTERNAL) Providing and fixing in position three dimensional building name using 18 gauge brush finish 304 grade stainless steel sheet lettering of width 38 mm x height 250 mm, projecting 25mm from the wall/partition/panelling and fixed at specified height in line and level by means of fully threaded stainless steel holdfast /studs which will be vertically welded to the back side of each letter. The stainless steel holdfast / studs will be inserted to the wall/partition/panelling by means of drilled holes and fixed with silicon for permanent fixing purpose and any other accessories etc. complete.All material shall be of approved make. All works complete as per the drawing/ Image, technical specification and direction of the Engineer. (Refer drawing number – UM-IN-501 to UM-IN-505)

4

-

-

... More
DECORATIVE GFRC PLANTER Providing and installing in position decorative planter in GFRC of size around 800mm dia x 800mm height of approved design, color, texture complete with handing over to client etc. All material shall be of approved make. All works complete as per the drawing, specification, image and direction of the Engineer (Refer drawing number – UM-IN-501 to UM-IN-505)

40

-

-

... More
CALCIUM SILICATE BOARD FALSE CEILING Providing and fixing 8mm thick calcuim silicate board suspended false ceiling false ceiling in horizontal / vertical surfaces, stepped, cove ( straight & curvature). The calcuim silicate board having density of 850 to 950kg/m3, shall be made from Siliceous & Calcareous material reinforced with fiber,made in Laminar process and then autoclaved to give stable crstalline structure. The framework shall consist of approved make Galvanised iron (GI) Perimeter Channel of 0.55 mm thickness, two unequal flanges of 20 mm and 30 mm and web of 27 mm fixed to surrounding walls / partition by using nylon sleeves and screws at 450 mm centres. Approved make Galvanised iron (GI) Intermediate Channel of 0.9 mm thickness having two equal flanges of 15 mm each and a web of 45 mm shall be suspended from the soffit at 1220 mm centre with G.I.Cleat and steel expansion fasteners. Galvanised iron (GI) Ceiling section of 0.55 mm thickness having web of 50.5 mm and flanges of 26 mm each with lips of 10.5 mm shall be fixed to the Intermediate channel with connecting clips across to the Intermediate channel at 457 mm centres.respectively. Calcuim silicate boards of 8 mm thickness having taper edge /Square edge shall be screw fixed across the ceiling sections with 25 mm long self drilling.The item shall include providing markings and cutouts for electrical fixtures,sprinklers,smoke detectors,diffusers,curtains etc. on the ceiling and also providing & fixing templates in the ceiling made of 12/19mm BWP (boiling water proof) plywood. All material shall be of approved make. Measurements shall be considered wall to wall without any deductions. All works shall be complete as per the drawing, specification and direction of the Engineer. (Refer drawing number – UM-IN-301 to UM-IN-305)

7665.47

-

-

... More
600X600MM CALCIUM SILICATE ACOUSTICAL TILE FALSE CEILING Providing & fixing 15mm thk densified tengular edged eco friendly light weight Calcium Silicate false ceiling tiles (like Aerolite Brand or Equivalent) of approved texture Spintone/ Cosmos/ Fine Fissured or equivalent of size 595mm x 595mm in true horizontal level, suspended on inter locking metal grid of hot dipped galvanized steel sections (galvanizing @120 grams per square metre. including both side) consisting of main "T" runner suitably spaced at joints to get required length & of size 24x38mm made from 0.33mm thk (minimum) sheet, spaced 1200mm center to center, and cross "T" of size 24x28mm made of 0.33mm thk (Minimum) sheet to be inter locked at middle of the 1200x600mm panel to from grid of size on a Perimeter wall angle precoated steel of size 600x600mm, resting on periphery walls/ partitions (24x24x300mm) made of 0.40mm thk (minimum) sheet with the help of rawl plugs at 450mm & laying 15mm thk densified edges calcium silicate ceiling tiles of approved texture light fittings, fixture, smoke detectors etc., wherever required. Main "T" runners to be suspended from ceiling using G.I. slotted cleats of size 25x35x1.6mm fixed to celing using with 12.5mm dia & 50mm long dash fastners, level clips of size 85x30x0.8mm, spaced at 1200mm center to center along main "T" bottom exposed with 24mm of T-section shall be pre-painted with polyester baked paint for all heights as per specifications,drawings etc. complete. Note: Only Calcium silicate false ceiling area will be measured from wall to wall. No deduction shall be made for exposed frames/ opening (cut outs) having area less than 0.30sqm. The Calcium silicate ceiling tile shall have NRC value of 0.50 (Minimum), light reflection85% non-combustible as per B.S.476 part IV, 100% humidity resistance and also having thermal conductivity 0.043 w/m 0 KC.The work shall be carried out as per specifications, drawing & as per directions of Engineer-in-Charge. With 15mm thk tegular edged light weight calcium silicate false ceiling tiles. The item shall include providing markings and cutouts for electrical fixtures, sprinklers, smoke detectors, diffusers, curtains etc. on the ceiling & also providing & fixing templates in the ceiling made of 12/19mm BWP (boiling water proof) plywood. All material shall be of approved make. All works shall be complete as per the drawing, specification and direction of the Engineer. (Refer drawing number – UM-IN-301 to UM-IN-305)

484.65

-

-

... More
PERFORATED GYPSUM PLASTERBOARD ACOUSTICAL FALSE CEILING Providing and fixing Perforated gypsum plasterboard Acoustical suspended ceiling. The framework shall have surface ribbed perimeter channels (having one flange of 20mm and another flange of 30mm and a web of 27mm) along the perimeter of ceiling, screw fixed to brick wall/partition with the help of nylon sleeves and screws, at 610mm centers. surface ribbed intermediate channels of size 45mm (with two flanges of 15mm each) shall be suspended from the soffit at 1200mm centers with surface ribbed ceiling angle of width 25mmx10mm fixed to soffit with GI cleat and steel expansion fasteners. Then surface ribbed ceiling section having web of 51.5mm and two flanges of 26mm each with lips of 10.5mm shall be fixed to the intermediate channel with the help of connecting clip and in direction perpendicular to the intermediate channel at 600mm centers. Single layer of 12.5mm perforated board of size 1200x2400mm having all four tapered edges, 16% perforation area of board and hole size of 12mm square shape, backed with acoustic tissue shall be screw fixed to ceiling section with 25mm drywall screws at 230mm centers. Screw fixing shall be done mechanically either with screw driver or drilling machine with suitable attachment. Square and tapered edges of the boards shall be jointed and finished so as to have a flush look which includes filling and finishing with Jointing compound, Joint Paper tape and two coats of drywall top coat. All material shall be of approved make. The item shall include providing markings and cutouts for electrical fixtures,sprinklers,smoke detectors,diffusers,curtains etc. on the ceiling and also providing & fixing templates in the ceiling made of 12/19mm BWP (boiling water proof) plywood. Measurements shall be considered wall to wall without any deductions. All complete as per the drawing, specification and direction of the Engineer. (Refer drawing number – UM-IN-301 to UM-IN-305)

701.56

-

-

... More
ALUMINIUM METAL TILE GRID FALSE CEILING Providing & fixing Plain Aluminium metal tile grid suspended false ceiling system with Lay-in type aluminium powder-coated panels & 15mm 'T' Framework. The Panels in form of tiles shall be lay-in type of size 584mm X 584 mm X 10 mm high making a module of 600mm X 600mm & shall be made out of 0.7mm thick aluminium with Square edges having recess flange of 15mm. The tile end shall be raised upward by 38mm and bend outward to lay the tile in framework. The tiles shall be made from corrosion resistant Al.-Mg. Alloy AA3105. The Tile shall be epoxy polyester powder coated with Antibac in white colour which is complaint to ROHS directive. The Primary Suspension shall consist of Pre punched 15mm width Main Tee section made out of GI. The exposed surface shall have an Aluminium coil coated cap. The Secondary suspension shall consist of pre-punched 15mm width cross tee section in 600mm and 1200mm size made out of GI. The exposed surface shall have an Aluminium coil coated cap. The 15mm main tee runners shall be suspended at an interval of 1200mm centre to centre. The 15mm cross tee runner shall be suspended at 600mm centre to centre and further supported with 15mm cross tee at 600mm centre to centre with interlocking arrangements to form grid of 600mm x 600mm. The main tee shall be supported by means of 4mm dia galvanised steel (G.I.) rod from slab/roof. The suspension shall be provided at 1200 to 1500mm centre to centre. The adjustment suspension clip shall be made of galvanised spring steel butterfly shaped with pre punched holes to accommodate the rod hanger. The wall trim shall be L Shape angle made of Aluminium 23mm X 23mm x 0.5mm having standard length of 3050mm with in ward bend. The item shall include providing markings and cutouts for electrical fixtures,sprinklers,smoke detectors,diffusers etc. on the ceiling and also providing & fixing templates in the ceiling made of 12mm BWR (boiling water proof) plywood. All material shall be of approved make. Measurements shall be considered wall to wall without any deductions. All works shall be complete as per the drawing, specification and direction of the Engineer. (Refer drawing number – UM-IN-301 to UM-IN-305)

330

-

-

... More
ALUMINIUM METAL BAFFLE FALSE CEILING Providing & fixing of horizontal level suspended ceiling comprising of Vertical Linear Baffle Ceiling made out of Aluminum Extrusion in Aluminum alloy grade 6063 T5. The baffle blade shall be in size of 100x25x3600mm in powder coated to Woodgrain/Plain finish (Red Oak, Cherry, Black & White).. The baffle shall be electrostatically polyester powder coated to a coating thickness of 60-80 micron. The powder coating shall pass Salt Spray Test for 750 Hours as per ASTM B117, QUV –A Test for 1000hours as per ASTM G-154 – (Cycle – 1) and Humidity test for 1000hours as per DIN 50017. The powder coating shall have an adhesion of GT0 as per EN ISO 2409. The shade variation within a manufacturing batch shall be delta E1 using Excite/BYK Gardner instrument and gloss level 25±5 at 60˚ as per ASTM D523 (Not applicable of Wood Grain Shade). The baffle blade shall be suspended using Slotted U-profile of 20 x 30 x 3700mm (Thk-1.5mm) having slots in module of 25mm to keep baffles at an on-center spacing in multiples of 25mm. Longer lengths of Baffle to be connected by Baffle Joiner and the ends to be fixed with End caps..SUSPENSION: Shall be hanged using baffle hanger from U-profile made of mild steel with powder coating thickness of 60-80 micron. The U – profile to comprise of alternate square & rectangular slots of 6.5x6.5mm & 28x6.5mm respectively on the web for locking the baffle hanger using plugin clip to secure the hanger in perfect position and achieve uniform spacing between baffles. The overall dimension of the U – profile is 20(W) x 30(H) x 3750(L) mm and is rolled form from 1.5mm thick mild steel with a powder coating thickness of 60-80micron. U- Profile to be connected to each other using U –Profile Splice. The U- profile shall be hanged from the true ceiling using threaded rod using a U- Profile hanger. The Baffle along with suspension system used together shall carry a 10 year warranty against manufacturing defect and manufacturer shall provide a warranty certificate. The supply shall be backed by a Manufacturing Test Certificate. (Refer drawing number – UM-IN-301 to UM-IN-305)

125

-

-

... More
Providing & fixing Below Mentioned Items made in fiber (FRP/GRP/ ANY OTHER MATERIAL SPECIFIED BY VENDOR) alongwith fabricating a rigid skeletal frame work by welding steel bars/weld mesh as per the desired size, shape and profile of the finished structure .Finish should be simillar to the photofeatures approved by the Architect. Rate should be inclusive of Scaffolding , reinforcement welding, framework as per structural design. Work should be as per detail design & drawing and satisfactory of the Architects. Mural wall in theming as per tender drawing

2850

-

-

... More
Providing & fixing Below Mentioned Items made in fiber (FRP/GRP/ ANY OTHER MATERIAL SPECIFIED BY VENDOR) alongwith fabricating a rigid skeletal frame work by welding steel bars/weld mesh as per the desired size, shape and profile of the finished structure .Finish should be simillar to the photofeatures approved by the Architect. Rate should be inclusive of Scaffolding , reinforcement welding, framework as per structural design. Work should be as per detail design & drawing and satisfactory of the Architects. Themed Painting as per tender drawing

4400

-

-

... More
Providing & fixing Below Mentioned Items made in fiber (FRP/GRP/ ANY OTHER MATERIAL SPECIFIED BY VENDOR) alongwith fabricating a rigid skeletal frame work by welding steel bars/weld mesh as per the desired size, shape and profile of the finished structure .Finish should be simillar to the photofeatures approved by the Architect. Rate should be inclusive of Scaffolding , reinforcement welding, framework as per structural design. Work should be as per detail design & drawing and satisfactory of the Architects. Sitting Benches of required Length in FRP as per tender drawing

25

-

-

... More
Providing & fixing Below Mentioned Items made in fiber (FRP/GRP/ ANY OTHER MATERIAL SPECIFIED BY VENDOR) alongwith fabricating a rigid skeletal frame work by welding steel bars/weld mesh as per the desired size, shape and profile of the finished structure .Finish should be simillar to the photofeatures approved by the Architect. Rate should be inclusive of Scaffolding , reinforcement welding, framework as per structural design. Work should be as per detail design & drawing and satisfactory of the Architects. Dustbin in single piece of Ht. 0.75m in FRP as per tender drawing

32

-

-

... More
Providing & fixing Below Mentioned Items made in fiber (FRP/GRP/ ANY OTHER MATERIAL SPECIFIED BY VENDOR) alongwith fabricating a rigid skeletal frame work by welding steel bars/weld mesh as per the desired size, shape and profile of the finished structure .Finish should be simillar to the photofeatures approved by the Architect. Rate should be inclusive of Scaffolding , reinforcement welding, framework as per structural design. Work should be as per detail design & drawing and satisfactory of the Architects. Drinking water fountain of Ht. 0.75m i in FRP as per tender drawing

5

-

-

... More
Providing & fixing Below Mentioned Items made in fiber (FRP/GRP/ ANY OTHER MATERIAL SPECIFIED BY VENDOR) alongwith fabricating a rigid skeletal frame work by welding steel bars/weld mesh as per the desired size, shape and profile of the finished structure .Finish should be simillar to the photofeatures approved by the Architect. Rate should be inclusive of Scaffolding , reinforcement welding, framework as per structural design. Work should be as per detail design & drawing and satisfactory of the Architects. Signages in FRP as per tender drawing

170.1

-

-

... More
Providing & fixing Below Mentioned Items made in fiber (FRP/GRP/ ANY OTHER MATERIAL SPECIFIED BY VENDOR) alongwith fabricating a rigid skeletal frame work by welding steel bars/weld mesh as per the desired size, shape and profile of the finished structure .Finish should be simillar to the photofeatures approved by the Architect. Rate should be inclusive of Scaffolding , reinforcement welding, framework as per structural design. Work should be as per detail design & drawing and satisfactory of the Architects. Railing of Ht 0.9 m in FRP as per tender drawing

125

-

-

... More
ELECTRICAL WORKS

-

-

-

... More
Supplying, installing, testing and commissioning SF 6 insulated 33kV, 630A, 16kA/3sec, 3 way outdoor, extensible motorised SCADA compatible RMU, internal arc tested as per electric supply company specification consisting of 2 nos. feeder with 3 LBS compliant to IEC 62271-100, 200 and 102 as per specification no. SW-HTS/RMU SCADA.

1

-

-

... More
Supplying, installing, testing and commissioning SF 6 insulated 33kV, 630A, 16kA/3sec, 3 way outdoor, extensible motorised SCADA compatible RMU, internal arc tested as per electric supply company specification consisting of 2 nos. feeder with 1 LBS and 2 nos. feeder with 2 VCB compliant to IEC 62271-100, 200 and 102 as per specification no. SW-HTS/RMU SCADA.

1

-

-

... More
Supplying, erecting, testing and commissioning 33KV HT metering cubical (compact type) approved by MSEDCL / licensee fabricated with 2 mm (14 SWG) M.S. sheets with supporting angle, painted with powder coating / epoxy paint of required shade, copper bus bar size 25 x 6 mm, heavy duty mechanical lock, with counter meter for measuring no. of times the opening of meter door, top side cover (CT, PT cover) interlock with meter door, epoxy casted 3 nos. CT having required ratio between 50/5A to 200/5A, VA 10 or 15, Class 0.2S, epoxy casted 3 nos. PT having ratio 33000/V3/110/V3 VA 50, Class 0.2 suitable for provided trivector meter, and provision for incoming and outgoing cables complete duly tested by licensee with necessary test certificates and erected on provided plinth/ cc foundation

1

-

-

... More
Supplying, installing, testing & commissioning 3 phase, 33/0.433 kV, 50 Hz., 800 kVA, Mineral oil immersed and naturally cooled outdoor type, Copper wound ,without gas cushioning ,hermetically Sealed transformer, delta/star connected with additional neutral brought out on load side, temperature rise should not exceed 45℃ by thermometer in oil and 50℃ by the resistance method in winding at full load rating, using type A winding insulation (kraft paper) with HV tapping (with on load tap changer) on load +5 to-15 in steps of 2.5%, with standard accessories complete with test certificate with losses below 2401 Watts at 50% load, 6723 Watts at 100% load as per IS:1180 (part 1) : 2014 with necessary permissions of Electrical Inspector, as per specification no SS- TR SL.

2

-

-

... More
Supply, Installation of 100X50X6 MS channel structural supports in horizontal and vertical formation & single / multi tier formation. The supports shall be painted with one coat of Red oxide and one or more coat of synthetic enamel paint. Quoted rates for installation shall include anchor fasteners, welding of supports etc to suit site conditions.

2500

-

-

... More
Supplying, erecting, testing and commissioning of diesel generating set with alternator of 750 kVA output continuous rating, 3 Phase, 415 V, 50c/s 0.8 p. f. A.C supply, a totally enclosed air cooled / liquid cooled multi-cylinder diesel engine developing suitable BHP at 1500 rpm with 10% overload for 1 hour in 12 hours, along with standard accessories, self-excited, self-regulated, screen protected alternator with static excitation system running at 1500 RPM as per IS 4722-2001 with voltage regulation +/- 5 %, with performance class G2 and maximum fuel consumption 126.4 Ltr/hr @75% loading. Both the engine and alternator direct coupled on a common fabricated steel base frame and mounted on anti-vibrating pads with standard control panel comprising meters, switchgears, indicators connected with suitable wires/cables, the complete set enclosed in composite acoustic enclosure as fully assembled integral unit made of 16 SWG CRCA sheet, sound absorbing material to restrict sound level up to 75 dB at 1.0 m, provided with first filling of oil, diesel not less than 990 Ltr etc. on provided M20 Grade CC Foundation and obtaining necessary approval from Electrical Inspector as per specification no. GEN-DG (Vendor to consider CPCB-4 Engine)

2

-

-

... More
Supplying, erecting, testing and commissioning of Microprocessor based Generator Control Unit (Synchronization panel) panel suitable for diesel generating set of above 500 kVA up to 750 kVA capacity Three phase, 415 Volts, 50Hz A.C. with all standard features and safeties etc as per specification no. GEN-SYNC.

1

-

-

... More
Supply, installation, testing and commissioning of TRANSFORMER-SECONDARY BREAKER PANEL , factory assembled, 415V, 15MVA, fully insulated metal enclosed cubicle type switchgear with 3phase and neutral, fully insulated, continuously rated shrouded Aluminium bus bars of required current carrying capacity with provision for extension at both ends. Bus bars shall withstand without damage a short circuit of 65kA for one second. The switchgear units shall be suitable for a supply system of 3phase, 4wire, 415V +/- 10%, 50Hz +/- 3%, Horizontal draw out type with stationary and moving sections designed for interlocked safe operation incase of air circuit breakers. The bus bar shall be suitably drilled for easy extension. There shall be a continuous aluminium earth bus throughout the perimeter of the bottom of the panel. All CT earthing shall be connected to this bus. All panel doors shall be connected to the body by at least two copper flexible. Bus duct / cable entry shall be from top/bottom. The cost of all consumables, accessories, loading & unloading, lead & lift, tools & tackles, machineries & equipments, wastages, scaffolding, transportation, packing & forwarding, shifting of debris outside the site premises shall be included in the quoted rates.All Meters will be BMS Comaptible & intigrited with energeny monitoring system on Web Page on OEM server , required hardware etc will be part of per panles & main Meter / data procoesor , Web page etc cost to be considered in main panel . (Refer SLD) Note:All MCCB will have Extended rotary handle & Spereader terminals on both side;All MCCB should have Ics=Icu 100%; All MCB will be rated for 10KA breaking capacity & C'curve characteristics;MCB in capacitor panel should be with D'curve characteristics; All Digital multifunction meter with Bright LED display to view more than 25 parameters. VLL, VLN, A (Avg. & Phase Wise), F ,Power: W, PF, VA (Avg. & Phase Wise) Energy: Wh,Positive energy accumulation even with CT polarity reversal with reverse lock programmable , High Accuracy with class 1 with BMS commpatable with RS485 modbus communication port

2

-

-

... More
Supply, installation, testing and commissioning of MAIN LT PANEL , factory assembled, 415V, 15MVA, fully insulated metal enclosed cubicle type switchgear with 3phase and neutral, fully insulated, continuously rated shrouded Aluminium bus bars of required current carrying capacity with provision for extension at both ends. Bus bars shall withstand without damage a short circuit of 65kA for one second. The switchgear units shall be suitable for a supply system of 3phase, 4wire, 415V +/- 10%, 50Hz +/- 3%, Horizontal draw out type with stationary and moving sections designed for interlocked safe operation incase of air circuit breakers. The bus bar shall be suitably drilled for easy extension. There shall be a continuous aluminium earth bus throughout the perimeter of the bottom of the panel. All CT earthing shall be connected to this bus. All panel doors shall be connected to the body by at least two copper flexible. Bus duct / cable entry shall be from top/bottom. The cost of all consumables, accessories, loading & unloading, lead & lift, tools & tackles, machineries & equipments, wastages, scaffolding, transportation, packing & forwarding, shifting of debris outside the site premises shall be included in the quoted rates.All Meters will be BMS Comaptible & intigrited with energeny monitoring system on Web Page on OEM server , required hardware etc will be part of per panles & main Meter / data procoesor , Web page etc cost to be considered in main panel . (Refer SLD) Note:All MCCB will have Extended rotary handle & Spereader terminals on both side;All MCCB should have Ics=Icu 100%; All MCB will be rated for 10KA breaking capacity & C'curve characteristics;MCB in capacitor panel should be with D'curve characteristics; All Digital multifunction meter with Bright LED display to view more than 25 parameters. VLL, VLN, A (Avg. & Phase Wise), F ,Power: W, PF, VA (Avg. & Phase Wise) Energy: Wh,Positive energy accumulation even with CT polarity reversal with reverse lock programmable , High Accuracy with class 1 with BMS commpatable with RS485 modbus communication port

2

-

-

... More
Supply, installation, testing and commissioning of METERING PANEL-1 , factory assembled, 415V, 15MVA, fully insulated metal enclosed cubicle type switchgear with 3phase and neutral, fully insulated, continuously rated shrouded Aluminium bus bars of required current carrying capacity with provision for extension at both ends. Bus bars shall withstand without damage a short circuit of 65kA for one second. The switchgear units shall be suitable for a supply system of 3phase, 4wire, 415V +/- 10%, 50Hz +/- 3%, Horizontal draw out type with stationary and moving sections designed for interlocked safe operation incase of air circuit breakers. The bus bar shall be suitably drilled for easy extension. There shall be a continuous aluminium earth bus throughout the perimeter of the bottom of the panel. All CT earthing shall be connected to this bus. All panel doors shall be connected to the body by at least two copper flexible. Bus duct / cable entry shall be from top/bottom. The cost of all consumables, accessories, loading & unloading, lead & lift, tools & tackles, machineries & equipments, wastages, scaffolding, transportation, packing & forwarding, shifting of debris outside the site premises shall be included in the quoted rates.All Meters will be BMS Comaptible & intigrited with energeny monitoring system on Web Page on OEM server , required hardware etc will be part of per panles & main Meter / data procoesor , Web page etc cost to be considered in main panel . (Refer SLD) Note:All MCCB will have Extended rotary handle & Spereader terminals on both side;All MCCB should have Ics=Icu 100%; All MCB will be rated for 10KA breaking capacity & C'curve characteristics;MCB in capacitor panel should be with D'curve characteristics; All Digital multifunction meter with Bright LED display to view more than 25 parameters. VLL, VLN, A (Avg. & Phase Wise), F ,Power: W, PF, VA (Avg. & Phase Wise) Energy: Wh,Positive energy accumulation even with CT polarity reversal with reverse lock programmable , High Accuracy with class 1 with BMS commpatable with RS485 modbus communication port

1

-

-

... More
Supply, installation, testing and commissioning of METERING PANEL-2 , factory assembled, 415V, 15MVA, fully insulated metal enclosed cubicle type switchgear with 3phase and neutral, fully insulated, continuously rated shrouded Aluminium bus bars of required current carrying capacity with provision for extension at both ends. Bus bars shall withstand without damage a short circuit of 65kA for one second. The switchgear units shall be suitable for a supply system of 3phase, 4wire, 415V +/- 10%, 50Hz +/- 3%, Horizontal draw out type with stationary and moving sections designed for interlocked safe operation incase of air circuit breakers. The bus bar shall be suitably drilled for easy extension. There shall be a continuous aluminium earth bus throughout the perimeter of the bottom of the panel. All CT earthing shall be connected to this bus. All panel doors shall be connected to the body by at least two copper flexible. Bus duct / cable entry shall be from top/bottom. The cost of all consumables, accessories, loading & unloading, lead & lift, tools & tackles, machineries & equipments, wastages, scaffolding, transportation, packing & forwarding, shifting of debris outside the site premises shall be included in the quoted rates.All Meters will be BMS Comaptible & intigrited with energeny monitoring system on Web Page on OEM server , required hardware etc will be part of per panles & main Meter / data procoesor , Web page etc cost to be considered in main panel . (Refer SLD) Note:All MCCB will have Extended rotary handle & Spereader terminals on both side;All MCCB should have Ics=Icu 100%; All MCB will be rated for 10KA breaking capacity & C'curve characteristics;MCB in capacitor panel should be with D'curve characteristics; All Digital multifunction meter with Bright LED display to view more than 25 parameters. VLL, VLN, A (Avg. & Phase Wise), F ,Power: W, PF, VA (Avg. & Phase Wise) Energy: Wh,Positive energy accumulation even with CT polarity reversal with reverse lock programmable , High Accuracy with class 1 with BMS commpatable with RS485 modbus communication port

1

-

-

... More
Supply, installation, testing and commissioning of METERING PANEL-3 , factory assembled, 415V, 15MVA, fully insulated metal enclosed cubicle type switchgear with 3phase and neutral, fully insulated, continuously rated shrouded Aluminium bus bars of required current carrying capacity with provision for extension at both ends. Bus bars shall withstand without damage a short circuit of 65kA for one second. The switchgear units shall be suitable for a supply system of 3phase, 4wire, 415V +/- 10%, 50Hz +/- 3%, Horizontal draw out type with stationary and moving sections designed for interlocked safe operation incase of air circuit breakers. The bus bar shall be suitably drilled for easy extension. There shall be a continuous aluminium earth bus throughout the perimeter of the bottom of the panel. All CT earthing shall be connected to this bus. All panel doors shall be connected to the body by at least two copper flexible. Bus duct / cable entry shall be from top/bottom. The cost of all consumables, accessories, loading & unloading, lead & lift, tools & tackles, machineries & equipments, wastages, scaffolding, transportation, packing & forwarding, shifting of debris outside the site premises shall be included in the quoted rates.All Meters will be BMS Comaptible & intigrited with energeny monitoring system on Web Page on OEM server , required hardware etc will be part of per panles & main Meter / data procoesor , Web page etc cost to be considered in main panel . (Refer SLD) Note:All MCCB will have Extended rotary handle & Spereader terminals on both side;All MCCB should have Ics=Icu 100%; All MCB will be rated for 10KA breaking capacity & C'curve characteristics;MCB in capacitor panel should be with D'curve characteristics; All Digital multifunction meter with Bright LED display to view more than 25 parameters. VLL, VLN, A (Avg. & Phase Wise), F ,Power: W, PF, VA (Avg. & Phase Wise) Energy: Wh,Positive energy accumulation even with CT polarity reversal with reverse lock programmable , High Accuracy with class 1 with BMS commpatable with RS485 modbus communication port

1

-

-

... More
Supply, installation, testing and commissioning of APFC PANEL 200KVAR , factory assembled, 415V, 15MVA, fully insulated metal enclosed cubicle type switchgear with 3phase and neutral, fully insulated, continuously rated shrouded Aluminium bus bars of required current carrying capacity with provision for extension at both ends. Bus bars shall withstand without damage a short circuit of 65kA for one second. The switchgear units shall be suitable for a supply system of 3phase, 4wire, 415V +/- 10%, 50Hz +/- 3%, Horizontal draw out type with stationary and moving sections designed for interlocked safe operation incase of air circuit breakers. The bus bar shall be suitably drilled for easy extension. There shall be a continuous aluminium earth bus throughout the perimeter of the bottom of the panel. All CT earthing shall be connected to this bus. All panel doors shall be connected to the body by at least two copper flexible. Bus duct / cable entry shall be from top/bottom. The cost of all consumables, accessories, loading & unloading, lead & lift, tools & tackles, machineries & equipments, wastages, scaffolding, transportation, packing & forwarding, shifting of debris outside the site premises shall be included in the quoted rates.All Meters will be BMS Comaptible & intigrited with energeny monitoring system on Web Page on OEM server , required hardware etc will be part of per panles & main Meter / data procoesor , Web page etc cost to be considered in main panel . (Refer SLD) Note:All MCCB will have Extended rotary handle & Spereader terminals on both side;All MCCB should have Ics=Icu 100%; All MCB will be rated for 10KA breaking capacity & C'curve characteristics;MCB in capacitor panel should be with D'curve characteristics; All Digital multifunction meter with Bright LED display to view more than 25 parameters. VLL, VLN, A (Avg. & Phase Wise), F ,Power: W, PF, VA (Avg. & Phase Wise) Energy: Wh,Positive energy accumulation even with CT polarity reversal with reverse lock programmable , High Accuracy with class 1 with BMS commpatable with RS485 modbus communication port

2

-

-

... More
Supply, installation, testing and commissioning of DG Outgoing Panel , factory assembled, 415V, 15MVA, fully insulated metal enclosed cubicle type switchgear with 3phase and neutral, fully insulated, continuously rated shrouded Aluminium bus bars of required current carrying capacity with provision for extension at both ends. Bus bars shall withstand without damage a short circuit of 65kA for one second. The switchgear units shall be suitable for a supply system of 3phase, 4wire, 415V +/- 10%, 50Hz +/- 3%, Horizontal draw out type with stationary and moving sections designed for interlocked safe operation incase of air circuit breakers. The bus bar shall be suitably drilled for easy extension. There shall be a continuous aluminium earth bus throughout the perimeter of the bottom of the panel. All CT earthing shall be connected to this bus. All panel doors shall be connected to the body by at least two copper flexible. Bus duct / cable entry shall be from top/bottom. The cost of all consumables, accessories, loading & unloading, lead & lift, tools & tackles, machineries & equipments, wastages, scaffolding, transportation, packing & forwarding, shifting of debris outside the site premises shall be included in the quoted rates.All Meters will be BMS Comaptible & intigrited with energeny monitoring system on Web Page on OEM server , required hardware etc will be part of per panles & main Meter / data procoesor , Web page etc cost to be considered in main panel . (Refer SLD) Note:All MCCB will have Extended rotary handle & Spereader terminals on both side;All MCCB should have Ics=Icu 100%; All MCB will be rated for 10KA breaking capacity & C'curve characteristics;MCB in capacitor panel should be with D'curve characteristics; All Digital multifunction meter with Bright LED display to view more than 25 parameters. VLL, VLN, A (Avg. & Phase Wise), F ,Power: W, PF, VA (Avg. & Phase Wise) Energy: Wh,Positive energy accumulation even with CT polarity reversal with reverse lock programmable , High Accuracy with class 1 with BMS commpatable with RS485 modbus communication port

1

-

-

... More
Supply, installation, testing and commissioning of Common Panel , factory assembled, 415V, 15MVA, fully insulated metal enclosed cubicle type switchgear with 3phase and neutral, fully insulated, continuously rated shrouded Aluminium bus bars of required current carrying capacity with provision for extension at both ends. Bus bars shall withstand without damage a short circuit of 65kA for one second. The switchgear units shall be suitable for a supply system of 3phase, 4wire, 415V +/- 10%, 50Hz +/- 3%, Horizontal draw out type with stationary and moving sections designed for interlocked safe operation incase of air circuit breakers. The bus bar shall be suitably drilled for easy extension. There shall be a continuous aluminium earth bus throughout the perimeter of the bottom of the panel. All CT earthing shall be connected to this bus. All panel doors shall be connected to the body by at least two copper flexible. Bus duct / cable entry shall be from top/bottom. The cost of all consumables, accessories, loading & unloading, lead & lift, tools & tackles, machineries & equipments, wastages, scaffolding, transportation, packing & forwarding, shifting of debris outside the site premises shall be included in the quoted rates.All Meters will be BMS Comaptible & intigrited with energeny monitoring system on Web Page on OEM server , required hardware etc will be part of per panles & main Meter / data procoesor , Web page etc cost to be considered in main panel . (Refer SLD) Note:All MCCB will have Extended rotary handle & Spereader terminals on both side;All MCCB should have Ics=Icu 100%; All MCB will be rated for 10KA breaking capacity & C'curve characteristics;MCB in capacitor panel should be with D'curve characteristics; All Digital multifunction meter with Bright LED display to view more than 25 parameters. VLL, VLN, A (Avg. & Phase Wise), F ,Power: W, PF, VA (Avg. & Phase Wise) Energy: Wh,Positive energy accumulation even with CT polarity reversal with reverse lock programmable , High Accuracy with class 1 with BMS commpatable with RS485 modbus communication port

1

-

-

... More
Supply, installation, testing and commissioning of Fire Emergency Panel , factory assembled, 415V, 15MVA, fully insulated metal enclosed cubicle type switchgear with 3phase and neutral, fully insulated, continuously rated shrouded Aluminium bus bars of required current carrying capacity with provision for extension at both ends. Bus bars shall withstand without damage a short circuit of 65kA for one second. The switchgear units shall be suitable for a supply system of 3phase, 4wire, 415V +/- 10%, 50Hz +/- 3%, Horizontal draw out type with stationary and moving sections designed for interlocked safe operation incase of air circuit breakers. The bus bar shall be suitably drilled for easy extension. There shall be a continuous aluminium earth bus throughout the perimeter of the bottom of the panel. All CT earthing shall be connected to this bus. All panel doors shall be connected to the body by at least two copper flexible. Bus duct / cable entry shall be from top/bottom. The cost of all consumables, accessories, loading & unloading, lead & lift, tools & tackles, machineries & equipments, wastages, scaffolding, transportation, packing & forwarding, shifting of debris outside the site premises shall be included in the quoted rates.All Meters will be BMS Comaptible & intigrited with energeny monitoring system on Web Page on OEM server , required hardware etc will be part of per panles & main Meter / data procoesor , Web page etc cost to be considered in main panel . (Refer SLD) Note:All MCCB will have Extended rotary handle & Spereader terminals on both side;All MCCB should have Ics=Icu 100%; All MCB will be rated for 10KA breaking capacity & C'curve characteristics;MCB in capacitor panel should be with D'curve characteristics; All Digital multifunction meter with Bright LED display to view more than 25 parameters. VLL, VLN, A (Avg. & Phase Wise), F ,Power: W, PF, VA (Avg. & Phase Wise) Energy: Wh,Positive energy accumulation even with CT polarity reversal with reverse lock programmable , High Accuracy with class 1 with BMS commpatable with RS485 modbus communication port

1

-

-

... More
SP MCB, 6 A to 32 A, 10 KA, C Series, Cat A

895

-

-

... More
TP MCB, 6 A to 32 A, 10 KA, C Series, Cat A

40

-

-

... More
TPN MCB, 6 A to 32 A, 10 KA, C Series, Cat A

58

-

-

... More
TPN MCB, 40 A, 10 KA, C Series, Cat A

13

-

-

... More
TPN MCB, 63 A, 10 KA, C Series, Cat A

3

-

-

... More
Isolator 4 Pole 40A, Cat A

64

-

-

... More
TPN MCB DB, double door, Horizontal type, 4 way ( 4 + 12), Cat A

63

-

-

... More
TPN MCB DB, double door, Horizontal type, 6 way ( 4 + 18), Cat A

5

-

-

... More
Supplying & erecting triple pole and neutral distribution board (TPNDB), SP/TP MCBs total 8 ways/24 poles, with door, 1.2mm thickness surface/flush mounted, IP43 Protection on provided iron/GI frame (vertical busbar type) as per specification no. SW-MCBDB.

6

-

-

... More
Supplying & erecting CRCA sheet metal one way enclosures of 1.2mm thickness suitable for DP MCB/TP MCB/FP MCB/RCCB/RCBO complete erected on provided angle iron/GI frame.

149

-

-

... More
Supplying & erecting triple pole and neutral distribution board (TPNDB), 3 pole MCCB as incomer & outgoing SP MCB (24 poles) or TP MCB of 8 ways (24poles), with door, 1.2mm thickness, surface/flush mounted, on provided iron/GI frame (vertical busbar type) as per specification no. SW-SWR/MCBDB1

5

-

-

... More
Supplying, erecting & commissioning 2 pole RCCB 16/25A, electromagnetic type with 30/100/300 mA sensitivity with earth leakage trip indication complete as per specification no. SW-RCCB.

14

-

-

... More
Supplying, erecting & commissioning 2 pole RCCB 40A, electromagnetic type with 30/100/300 mA sensitivity with earth leakage trip indication complete as per specification no. SW-RCCB.

7

-

-

... More
Supplying, fixing and commissioning 4 pole RCBO up to 25A, with overcurrent, rated short-circuit breaking capacity (10 kA) and earth leakage protection, with 30/100/300 mA sensitivity and short circuit and earth leakage trip indications per specification no SW-RCBO.

55

-

-

... More
Supplying, fixing and commissioning 4 pole RCBO 32/40A, with overcurrent, rated short-circuit breaking capacity (10 kA) and earth leakage protection, with 30/100/300 mA sensitivity and short circuit and earth leakage trip indication as per pecification no SW-RCBO.

21

-

-

... More
Supplying, fixing and commissioning 4 pole RCBO 63A, with overcurrent, rated short-circuit breaking capacity (10 kA) and earth leakage protection, with 30/100/300 mA sensitivity and short circuit and earth leakage trip indication as per specification no SW-RCBO.

6

-

-

... More
Armoured PVC/XLPE 1100 V cable 3 1/2 core 35sq.mm aluminium

1145

-

-

... More
Armoured PVC/XLPE 1100 V cable 3 1/2 core 50sq.mm aluminium

496

-

-

... More
Armoured PVC/XLPE 1100 V cable 3 1/2 core 70sq.mm aluminium

105

-

-

... More
Armoured PVC/XLPE 1100 V cable 3 1/2 core 95sq.mm aluminium

30

-

-

... More
Armoured PVC/XLPE 1100 V cable 3 1/2 core 120sq.mm aluminium

435

-

-

... More
Armoured PVC/XLPE 1100 V cable 3 1/2 core 150sq.mm aluminium

175

-

-

... More
Armoured PVC/XLPE 1100 V cable 3 1/2 core 240sq.mm aluminium

115

-

-

... More
Armoured PVC/XLPE 1100 V cable 3 1/2 core 300sq.mm aluminium

3000

-

-

... More
Armoured PVC/XLPE 1100 V cable 4 core 25sq.mm aluminium

4457

-

-

... More
Armoured PVC/XLPE 1100 V cable 3 core 2.5sq.mm copper

1250

-

-

... More
Armoured PVC/XLPE 1100 V cable 4 core 4 sq.mm copper

5130

-

-

... More
Armoured PVC/XLPE 1100 V cable 4 core 6 sq.mm copper

2260

-

-

... More
Armoured PVC/XLPE 1100 V cable 4 core 10 sq.mm copper

156

-

-

... More
Armoured PVC/XLPE 1100 V cable 4 core 16 sq.mm copper

598

-

-

... More
XPLE HT armoured cable 33 KV size 3 core 300 sq.mm(Earthed)

2000

-

-

... More
XLPE HT armoured cable 33 KV size 3 core 120 sq.mm(Earthed)

50

-

-

... More
Providing and erecting Heat shrinkable indoor termination kit for 33 kV ( E )/33 kV (UE) XLPE HT cable 3x300 sq. mm. to 400 sq. mm. with necessary material as per specification no. CB-JT/HT

6

-

-

... More
Providing and erecting Heat shrinkable indoor termination kit for 33 kV ( E )/33 kV (UE) XLPE HT cable 3x95 to 150 sq. mm. with necessary material as per specification no. CB-JT/HT

4

-

-

... More
Cable Gland Nickel plated single compresion type 1"

382

-

-

... More
Cable Gland Nickel plated single compresion type 1-1/8"

6

-

-

... More
Cable Gland Nickel plated single compresion type 1-1/4"

2

-

-

... More
Cable Gland Nickel plated single compresion type 1-3/8"

2

-

-

... More
Cable Gland Nickel plated single compresion type 1-1/2"

10

-

-

... More
Cable Gland Nickel plated single compresion type 1-3/4"

12

-

-

... More
Cable Gland Nickel plated single compresion type 2-1/4"

8

-

-

... More
Cable Gland Nickel plated single compresion type 2-1/2"

44

-

-

... More
Copper Terminal lug, single, medium duty, 2.5-5

48

-

-

... More
Copper Terminal lug, single, medium duty, 4-6

1640

-

-

... More
Copper Terminal lug, single, medium duty, 10-6

264

-

-

... More
Copper Terminal lug, single, medium duty, 16-6

112

-

-

... More
Copper Terminal lug, single, medium duty, 35-6

10

-

-

... More
Copper Terminal lug, single, medium duty, 50-6

14

-

-

... More
Copper Terminal lug, single, medium duty, 70-8

6

-

-

... More
Copper Terminal lug, single, medium duty, 95-10

22

-

-

... More
Copper Terminal lug, single, medium duty, 185-12

12

-

-

... More
Aluminium Terminal lug, single, medium duty, 25-8/10/12

336

-

-

... More
Aluminium Terminal lug, single, medium duty, 35-8/10

56

-

-

... More
Aluminium Terminal lug, single, medium duty, 50-8/10/12

24

-

-

... More
Aluminium Terminal lug, single, medium duty, 70-8/10/12

8

-

-

... More
Aluminium Terminal lug, single, medium duty, 95-10/12/16

8

-

-

... More
Aluminium Terminal lug, single, medium duty, 120-10/12/16

40

-

-

... More
Aluminium Terminal lug, single, medium duty, 150-10/12/16

48

-

-

... More
Aluminium Terminal lug, single, medium duty, 240-12/16

32

-

-

... More
Aluminium Terminal lug, single, medium duty, 300-16

136

-

-

... More
Ladder Type Trays150 mm width X 50 mm depth with runner size 15x50x15mm, rung size 20x40x20mm with rungs at 250mm c/c.(14SWG)

350

-

-

... More
Ladder Type Trays 300 mm width X 50 mm depth with runner size 15x50x15mm, rung size 20x40x20mm with rungs at 250mm c/c.(14SWG)

480

-

-

... More
Ladder Type Trays 600 mm width X 50 mm depth with runner size 15x50x15mm, rung size 20x40x20mm with rungs at 250mm c/c.(12SWG)

100

-

-

... More
Ladder Type Trays 1000 mm width X 50 mm depth with runner size 15x50x15mm, rung size 20x40x20mm with rungs at 250mm c/c.(12SWG)

350

-

-

... More
Supplying & laying (including excavation) reinforced cement concrete pipe of IS 458:2003 NP-2 class of 150 mm internal diameter in proper line, level and slope including providing and fixing collars in cement mortar 1:2 and curing etc. complete.

130

-

-

... More
Supplying & laying (including excavation) reinforced cement concrete pipe of IS 458:2003 NP-2 class of 250 mm internal diameter in proper line, level and slope including providing and fixing collars in cement mortar 1:2 and curing etc. complete.

200

-

-

... More
Supplying & laying (including excavation) half round reinforced cement concrete pipe of IS 458:2003 NP-2 class of 250 mm internal diameter in proper line, level and slope including providing and fixing collars in cement mortar 1:2 and curing etc. complete.

2000

-

-

... More
Supplying and laying (including excavation of suitable width & depth up to 90cm) 50 mm outside dia. double wall corrugated pipes (DWC) of HDPE for enclosing cable below ground/road surface, to required depth complete.

900

-

-

... More
Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface PVC conduit(medium) with modular switch, modular plates, suitable size modular GI box of specified Category and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required. (c) Group C -- with Cat A Modular Accessories

776

-

-

... More
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor single core cable in the independent surface PVC conduit ( medium)of appropriate size as required. (a) 2 x 1.5 sq.mm + 1 x 1.5 sq.mm earthwire (20mm Conduit)

200

-

-

... More
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor single core cable in the independent surface PVC conduit ( medium)of appropriate size as required. (b) 2 x 2.5 sq.mm + 1 x 2.5 sq.mm earthwire (20mm Conduit)

5315

-

-

... More
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor single core cable in the independent surface PVC conduit ( medium)of appropriate size as required. (c) 2 x 4 sq.mm + 1 x 4 sq.mm earthwire (20mm Conduit)

200

-

-

... More
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor single core cable in the independent surface PVC conduit ( medium)of appropriate size as required. (h) 4 x 2.5 sq.mm + 2 x 2.5 sq.mm earthwire (25mm Conduit)

300

-

-

... More
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor single core cable in the independent surface PVC conduit ( medium)of appropriate size as required. (i) 4 x 4 sq.mm + 2 x 4 sq.mm earthwire (25mm Conduit)

188

-

-

... More
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor single core cable in the independent surface PVC conduit ( medium)of appropriate size as required. (j) 4 x 6 sq.mm + 2 x 6 sq.mm earthwire (32mm Conduit)

32

-

-

... More
PVC insulated unsheathed single core Industrial fexible cable conforming to IS 694:1990 with flexible bright annealed electrolytic copper conductor for voltage upto 1100V. Size 35 sq mm

10

-

-

... More
Pvc insulated unsheathed single core Industrial fexible cable conforming to IS 694:1990 with flexible bright annealed electrolytic copper conductor for voltage upto 1100V. Size 50 sq mm

14

-

-

... More
Pvc insulated unsheathed single core Industrial fexible cable conforming to IS 694:1990 with flexible bright annealed electrolytic copper conductor for voltage upto 1100V. Size 70 sq mm

6

-

-

... More
Pvc insulated unsheathed single core Industrial fexible cable conforming to IS 694:1990 withflexible bright annealed electrolytic copper conductor for voltage upto 1100V. Size 95 sq mm

22

-

-

... More
Pvc insulated unsheathed single core Industrial fexible cable conforming to IS 694:1990 with flexible bright annealed electrolytic copper conductor for voltage upto 1100V. Size 185 sq mm

12

-

-

... More
Wiring for group controlled light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface PVC conduit( medium) and earthing the point with 1.5sq.mm FRLS PVC insulated copper conductor single core cable etc. as required.

1300

-

-

... More
Industrial socket outlet, 20 A, SPN with plug top and chained, Cat A

10

-

-

... More
Industrial socket outlet, 30 A, TPN with plug top and chained, Cat A

4

-

-

... More
Modular GI Box for 1/2 module, Cat B

50

-

-

... More
Modular GI Box for 3 module, Cat B

162

-

-

... More
Modular GI Box for 6 module, Cat B

36

-

-

... More
SP 5/6 A one way modular switch ISI marked, Cat B

140

-

-

... More
SP 15/16 A one way modular switch ISI marked,Cat B

50

-

-

... More
3 pin 5/6 A modular socket outlet ISI marked, Cat B

140

-

-

... More
6 pin 15/16 A modular socket outlet ISI marked, Cat B

50

-

-

... More
Stepped type Modular 2 module Fan Regulator, Cat B

400

-

-

... More
Telephone socket outlet modular type, Cat B

72

-

-

... More
Modular base & cover plate for 1 module, Cat B

72

-

-

... More
Modular base & cover plate for 3 module, Cat B

162

-

-

... More
Modular base & cover plate for 6 module, Cat B

36

-

-

... More
Supply, installation, testing & commissioning of fixtures & fittings, ceiling fans, exhaust fans, etc. complete with accessories, tube/lamp etc in on surface of slab/beam by 2 nos (minimum) of 6 mm anchor fasteners or on wall with 2 nos of wood screws, nylon plug etc., suitable supporting frame fixed with rag bolts grouted on the wall/anchor fastener on the beam/on the column & other fixing accessories etc provision & connection with 1.5 sq.mm multistranded copper conductor FRLS PVC wires etc., all as per drawing, specifications & as per the instruction of E.I.C. 30W LED RECESSED DOWN LIGHT CCT 4000K, IP-20, 100-LPW Note: 1) Sample fixture/fittings/lamps shall be got approved from Department and Architects with complete technical data.2) Cost of lamps to be included in installation rate.3) All fixtures shall be with low loss electronic ballast 4) LM79 and LM80 reports must be submitted from a NABL accredited laboratory. 5) BIS certificate for driver as well as the luminaire must be submitted for records. Driver and luminaire shall be of same make.

176

-

-

... More
Supplying and erecting LED square / circular Max. 25 W down lighter / Panel Light having pressure die-cast aluminium housing, polystyrene diffuser having system lumens output of Min. 2750 Lumens, min. efficacy of 110 lumen/W, CRI80, CCT upto 6500K, Beam Angle of 120 deg., max. ripple of 5%, THD10%, p.f. 0.95, operating range of 120-270V, surge protection of 2.5 kV, Life class of 50,000 Hrs at L70B50 including driver, having mounting arrangement with board for surface type or spring loaded mounting clips complete with minimum 2 years warranty as per specification No. FG-IDF/LED.

966

-

-

... More
Supplying and erecting LED square / circular Max. 18 W down lighter / Panel Light having pressure die-cast aluminium housing, polystyrene diffuser having system lumens output of Min. 2000 Lumens, min. efficacy of 110 lumen/W, CRI80, CCT upto 6500K, Beam Angle of 120 deg., max. ripple of 5%, THD10%, p.f. 0.95, operating range of 120-270V, surge protection of 2.5 kV, Life class of 50,000 Hrs at L70B0 including driver, having mounting arrangement with board for surface type or spring loaded mounting clips complete with minimum 2 years warranty as per specification No. FG-IDF/LED.

145

-

-

... More
Supplying and erecting integrated LED Post Top 45W IP65 & IK10 class having die cast aluminium housing with UV protected polycarbonate diffuser, having system lumens output of Min.4500 Lumens, min. efficacy of 105 lumen/W, CRI80, CCT upto 6500K, THD10%, p.f. 0.90, operating range of 140-240V, inbuilt surge protection of 2 kV, Life class of 30,000 Hrs at L50B50 , including driver complete with minimum 2 Year warranty as per specification No FG-ODF/PT.

50

-

-

... More
Supplying and erecting 45W LED DECORATIVE STREET LIGHT IP-65 WITH 7MTR POLE

52

-

-

... More
Supplying and erecting LED STRIP LIGHT 5W/MTR CCT 3000K

900

-

-

... More
Supplying and erecting 1MTR AL MATERIAL TRACK WITH 3NOS 10W TRACK LIGHTS

20

-

-

... More
Supplying and erecting 2WAY WALL LIGHT IP65 10W

50

-

-

... More
Supplying and erecting 30W 2FTX2FT RECESSED LED LIGHT CCT 5700K, IP-20, 100-LPW

208

-

-

... More
Supplying and erecting 30W LED LINEAR SUSPENDED LIGHT, 50MM WIDE, 1200MM LONG, CCT 4000K, IP-20, 115-LPW

125

-

-

... More
Supplying and erecting Energy Saving BLDC Ceiling fan 230 V A.C. 50 cycles 1200 mm, max. energy consumption of 28W having service ratio (CMM/W) of Min. 8 , PF0.9, THD10% with IR remote control/compatible speed regulator, Temperature Rise of Max. 40 deg. C, having external mounted control PCB completely erected in position as per specification no. FG-FN/CF

400

-

-

... More
Supplying and erecting Bulkhead luminaire suitable for CFL lamp Cat A

36

-

-

... More
Supply and providing Chemical earthing system (Pipe in pipe type) with Outer pipe of the electrode having minimum 80mm diameter as per the enclosed specifiations and drawing.The outer and the inner hot dip galvanised MS pipes shall conform to the specifications and the space inbetween shall be filled with highly crystalline conductive and anti- corrosive mixture conforming to IS-3043. The earth electrode shall be CPRI tested.The scope of work includes boring( 300mm dia mimnimum)/exvavation of soil/hard rock, refilling with required quantity of back fill compound/Ground resistance enhancement powder of requisite quantity, compaction, constuction of masonary chamber etc complete as required to obtain the desired value.Aluminium tag with embossed earthing value shall be permanently attached to the pipe electrode (a) 3 metres length electrode

28

-

-

... More
Supplying and laying 8 SWG copper wire at 0.5 m belowground level for conductor earth electrode includingsoldering etc. as required

1152

-

-

... More
Supplying and laying 25 mm x 5 mm copper strip in 40 mm dia GI pipe from earth electrode as required

100

-

-

... More
Supplying and erecting GI strip of high purity required size used for earthing on wall and/or any other purpose with necessary GI clamps fixed on wall painted with bituminous paint with joints required. As per specification no EA-EP.

230

-

-

... More
Supplying and erecting GI wire of high purity of required sizes used for earthing or any other purposes on wall with necessary G. I. Clamps fixed on wall/cable/ conduit with screws complete.

7168

-

-

... More
Supplying and drawing/fixing indoor type 0.5sq.mm FR PVC insulated copper conductor unarmoured telephone cable ITD/DOT approved, with GI saddles on wal or in the existing surface/recesed steel/PVC conduit having folowing pair(s), complete as required. (a) 2 Pair

2900

-

-

... More
Supplying, installing, testing and commissioning of Junction Box, ITD/DOT approved, indoor type with wall mounting/concealed facility having front door with lock along with aluminium frame for mounting disconnection type Krone modules, complete cabinet fabricated from 18 SWG CRCA sheet with powder coating in appropriate manner and suitable for following capacity of pairs, including Krone makemodules, crimping and terminations, etc. complete as required. (a) 10 Pair

1

-

-

... More
Supplying, installing, testing and commissioning of Junction Box, ITD/DOT approved, indoor type with wall mounting/concealed facility having front door with lock along with aluminium frame for mounting disconnection type Krone modules, complete cabinet fabricated from 18 SWG CRCA sheet with powder coating in appropriate manner and suitable for following capacity of pairs, including Krone makemodules, crimping and terminations, etc. complete as required. (a) 20 Pair

12

-

-

... More
Supplying, installing, testing and commissioning of Junction Box, ITD/DOT approved, indoor type with wall mounting/concealed facility having front door with lock along with aluminium frame for mounting disconnection type Krone modules, complete cabinet fabricated from 18 SWG CRCA sheet with powder coating in appropriate manner and suitable for following capacity of pairs, including Krone makemodules, crimping and terminations, etc. complete as required. (a) 100 Pair

2

-

-

... More
Supplying, erecting and commissioning of 10006 Discoonection type Krone Module, ITD.DOT approved, having capacity of 10 pairs with silver plated terminal contacts, complete as required.

44

-

-

... More
Supplying and drawing of Cat - 6 UTP, 4 pair annealed tinned copper conductor PVC insulated, PVC sheathed, unarmoured data cable in existing surface/recessed steel/PVC conduit of appropriate size including connection, etc. complete as required (a) Cat 6

6400

-

-

... More
Supplying, installation and testing of suitable size modular GI box , modular plate and cover complete with RJ-45 connector(modular LAN socket TX1000/ CAT6) including concealed metal box/surface GI/PVC Box, modular plate, punching, identifying, complete as required. CAT B

68

-

-

... More
Supplying, installation and testing of suitable size modular GI box , modular plate and cover complete with RJ-11 connector(modular telephone socket) including concealed metal box/surface GI/PVC Box, modular plate, punching, identifying, complete as required. . CAT B

68

-

-

... More
Supplying and erecting 12 fibers LSZH armoured multimode optical fiber cable with , core dia 50/125 µm (OM3), suitable upto 10 GBPS, compliant to IEC 60793/IEC 60794 standards, on wall/ceiling or laid in provided pipe/trench as per specification no. WG-ELVC/OFC

200

-

-

... More
Supplying, fixing, and configuring 48 ports managed gigabit switch 10/100/1000 Mbps + 4SFP+ ports & 2X10G RJ-45 ports compliant with IEEE 802.3 af/at standards & supports OSPF/policy based routing/stacking erected in provided rack complete.

1

-

-

... More
Supplying, fixing, and configuring 24 ports managed gigabit switch 10/100/1000 Mbps + 4SFP+ ports & 2X10G RJ-45 ports compliant with IEEE 802.3 af/at standards & supports OSPF/policy based routing/Stacking erected in provided rack complete.

8

-

-

... More
Supplying and fixing Cat 6, keystone jack RJ-45 information outlet compliant with ANSI/TIA/EIA 568.C.2 & ISO/IEC 11810 (ethernet) as per specification no. WG-NAS/KJ

100

-

-

... More
upplying and fixing SC/SC type multimode pigtails (OM3) for LIU to erminate OFC in LIU as per specification no. WG-NAS/LIU2

8

-

-

... More
Supplying and fixing Cat 6, 24 port patch panel with keystone jacks compliant with ANSI/TIA/EIA 568.C.2 & ISO/IEC 11810 complete as per specification no. WG-NAS/PP

8

-

-

... More
Supplying and fixing 6U wall mount rack (Dimension-DxWxH – 500x600x367mm) as per specification No. WG-NAS/RAK

8

-

-

... More
Supply,installation ,testing & Commissioning of IP based Vandal proof 5MP IR Indoor Dome Varifocal Camera -HD, Pixel 2688 × 1520, 1/3" CMOS, 42 pcs LEDs, 40m IR, Indoor Vari-focal turret, ICR, 0.01 Lux/F1.2, 12 VDC, Smart IR, DNR, IP66, 2.8-12mm Lens, Support TVI/AHD/CVI/CVBS video signal output

74

-

-

... More
Supply , Installation , Testing and Commissioning of NVR 32 IP Channel Inputs; HDMI, 1/1 Audio I/O and 2/1 Alarm I/O; 12MP, 8MP, 5MP, 4MP, 3MP, 2MP, 720p, D1 and CIF Recording Resolution; 4x 4K/ 10x 3MP/16x 1080p Local Decoding; 4 SATA HDD Support; Save Storage Space with Adaptive Recording and Camera-wise Recording Retention; SMS & Email Notification, Video Pop-up, Alarms and Calling from Mobile Application; 512Mbps Throughput - 256 Uplink, 256 Downlink; Cascading: Create Multiple NVR Clusters to Monitor and Control Multiple Matrix NVRs Centrally

3

-

-

... More
Supply Installation Testing and Comissioning of 32'' Commercial Television with wall mount accessories. The CCTV monitors shall be the perfect professional security monitor with Full HD a native 1920x1080 panel resolution optimized for CCTV applications and designed for 24/7 use. Benefiting from the latest onboard LED panel technology that offers excellent picture quality along with a fast 8ms response time. Shall offer 600TV lines high resolution and various video output via HDMI, VGA. Built-in Speaker, Accessories : Wall Mount stand.

1

-

-

... More
Supply , Installation , Testing and commissioning  of HDD, 6TB, 7200 RPM, SATA 6 Gb/s, including fixing accessories and cable termination with required, complete in all respect as per instruction of engineer in-charge. Make:WD

14

-

-

... More
Supplying, fixing, and configuring 24 ports with 4 combo SFP Port ethernet managed switch compliant with IEEE 802.3 standards, min. 370W PoE capacity, with web view ethernet port for management in provided rack as per specification no. WG-NWC/GBS

9

-

-

... More
upplying and fixing SC/SC type multimode pigtails (OM3) for LIU to erminate OFC in LIU as per specification no. WG-NAS/LIU2

9

-

-

... More
Supplying and fixing 6U wall mount rack (Dimension-DxWxH – 500x600x367mm) as per specification No. WG-NAS/RAK

9

-

-

... More
Supplying and fixing 42U floor mount server rack (Dimension-DxWxH –800x600x1866 mm) as per specification No. WG-NAS/RAK

1

-

-

... More
Supplying, erecting, testing & commissioning of 10 kVA capacity on line pure sine wave,PWM,IGBT based UPS with 0.9 to unity output pf ,3 phase input & 3 phase output complete with all protections as per specification no. APUPS(Without batteries)

1

-

-

... More
Supplying and erecting 12 V/65Ah SMF battery with battery terminal wire, duly charged complete with 24 months warranty completeSupplying and erecting 12V/65Ah SMF battery with battery terminal wire, duly charged complete with 24 months warranty complete

10

-

-

... More
Supplying, installing, testing and commissioning of 20 kWp ON-GRID Solar PV System / Plant consisting Solar PV Poly Crystalline Panel (335 Wp X 60Nos.) and Solar ON-GRID Inverter of similar capacity (THD3%) with interconnecting wires / cables up to solar ON GRID inverter, proper base plate, canopy box to house Inverter and necessary accessories i.e. ACDB/ DCDB , MCB etc. wiring up to solar Inverter in casing and capping, display board, sign board, two distinct earthing, lightning arrester, liaisoning charges, remote monitoring system with maintaining card/chip for 5 years including net charges for RMS System, complete up to net meter installation and export to the grid with 5 year ON-SITE warranty and fully comprehensive maintenance contract as per Specification no. ESD-RT-ONG.

2

-

-

... More
Supplying, erecting, testing and commissioning of 10kW, 3 x 3.3 KW AC Electric Vehicle charger (suitable for 2/3/4 wheeler) having minimum IK08/IP 54 Protection suitable for three phase, 415V AC, 50Hz incoming and 3 nos. output as per IEC 60309 industrial sockets having capacity of output current of 16A 240V AC at each socket with 3.5"TFT touch screen for human interface & LED Light for status indication and metering for measurement of consumed energy having metering accuracy +/-1%, one hour battery backup for communication, emergency push stop button and having short circuit, over & under voltage, overload, over temperature, earth leakage protection and enclosure made of minimum 1.5mm duly RAL7035 Coated M.S, Erected on iron/GI frame on provided cement concrete foundation complete with one year on site warranty, confirming to IS 17017 Series as per specification.

1

-

-

... More
Supply, Installation, Testing and Commissioning 7.2 kW AC Electric Vehicle charger (suitable for 4 wheeler) having minimum IK08 & IP54 protection suitable for single phase, 230V AC, 50Hz, incoming and 1 nos. output having capacity of output current of 32A at 230V with Type two connector as per IEC 62196-2 , Interlocking arrangement & minimum 5 meter charging cable length, 3.5" TFT screen for human interface & LED light for status indication and metering for measurement of consumed energy having metering accuracy +/1%, one hour battery backup for server communication, emergency push stop button, with user interface by mobile application/QR Code/RIFD Card/Password Login and having short circuit, over & under voltage, overload,earth leakage ,Over temperature, surge protection and enclosure made of minimum 1.5mm duly RAL7035 coated M.S, erected on iron/GI frame on provided cement concrete foundation complete with one year on site warranty, confirming to IS 17017 Series as per specification

1

-

-

... More
Supply installation Testing & commissioning of Microprocessor based, 600 character LCD display, alpha numeric touch keypad, Fire Alarm Panel having following features, - Networkable with Repeater panels and for Peer to Peer Networking.- 24V Battery back up of 24 hour in normal condition and 30 minute in alarm condition. - Each loop to be provided with 20% spare capacity. 125 detectors and 125 module per loop- To be integrated with Public address system for voice evacuation, lifts, Ventilation system etc. - To be integrated with Fire Fighter Communication system. Each floor Telephone jack to be provided with address. - Total Panel capacity shall be as per below quantities. - Provision for printing the event history 4000 logs. - The 24V Battery shall be capable of providing 24V supply to Hooters/Control Module. - The Panel shall be networkable on fiber optics network. The media convertor rate shall be inlcude if required. -Panel to have integrated DVC with Amplifier cabapble of handling speakers load as per boq with 8 zones requirement. . Approval: UL Listed & FM Approved

1

-

-

... More
Supply installation Testing & commissioning of Active Repeater Panel with 600 LCD display. UL Listed & FM Approved

1

-

-

... More
Supply installation Testing & commissioning of Analogue Addressable Photoelectric type Smoke Detector with all mounting accessories , complete with MS Powder coated Junction Box for mounting on Surface, Cable lugs at Ends, cable compression glands, cable tags and Ferruling. UL Listed & FM Approved

355

-

-

... More
Supply installation Testing & commissioning of Analogue Addressable Multisensor detector ( Photo + Thermal) with all mounting accessories , complete with MS Powder coated Junction Box for mounting on Surface, Cable lugs at Ends, cable compression glands, cable tags and Ferruling. UL Listed & FM Approved

13

-

-

... More
Supply installation Testing & commissioning of Analogue Addressable Heat detector with ROR feature with all mounting accessories , complete with MS Powder coated Junction Box for mounting on Surface, Cable lugs at Ends, cable compression glands, cable tags and Ferruling. UL Listed & FM Approved

2

-

-

... More
Supply installation Testing & commissioning of Addressable Monitor Module with all mounting accessories , complete with MS Powder coated Junction Box for moounting on Surface, Cable lugs at Ends, cable compression glands, cable tags and Ferruling. UL Listed & FM Approved

26

-

-

... More
Supply installation Testing & commissioning of Addressable Relay Module in suitable ABS Plastic glossy Box If required Shall be complete with Pilot Relay for Tripping of Third Party Equipment, suitable for switching 5A/15A current through the Relay contacts ,with MS Powder coated Junction Box for mounting on Surface, Cable lugs at Ends, cable compression glands, cable tags and Ferruling. UL Listed & FM Approved

2

-

-

... More
Supply installation Testing & commissioning of Ceiling / Wall mounted Hooter cum Strobes. The Hooter cum Strobes shall be made of ABS plastic and have the Db level of 75dbs at 10ft and a multi tone facility, Strobes intensity should be 15 to 115 Candela. With all mounting accessories , complete with MS Powder coated Junction Box for mounting on Surface, Cable lugs at Ends, cable compression glands, cable tags and Ferruling. UL Listed

26

-

-

... More
Supply installation Testing & commissioning of Addressable Control Module in suitable ABS Plastic glossy Box. The module shall have supervised NAC output to connect notification devices like hooter cum strobe with MS Powder coated Junction Box for mounting on Surface, Cable lugs at Ends, cable compression glands, cable tags and Ferruling. UL Listed & FM Approved

11

-

-

... More
Supply, Installation, Testing & Commissioning of Addressable Manual Pull Station/Call Point break glass type with Address Switch and all mounting accessories , complete with MS Powder coated Junction Box for mounting on Surface, Cable lugs at Ends, cable compression glands, cable tags and Ferruling. UL Listed FM Approved

26

-

-

... More
Supply installation Testing & commissioning of Response Indicator with all mounting accessories , complete with MS Powder coated Junction Box for mounting on Surface, Cable lugs at Ends, cable compression glands, cable tags and Ferruling.

139

-

-

... More
Supply and laying of 2C 1.5 sqmm, Multistranded Copper, FRLS, Sheilded , Armoured cable, RED in Colour.

3000

-

-

... More
Supply, installation, testing and commissioning of of 6W (6W tap) Ceiling Mounted Speaker with all mounting accessories as required.

158

-

-

... More
Supply,installation ,testing & Commissioning of Voice Alarm Controller with Expander (Equivalent of Bosch PVA-4CR12 Controller) having features like announcement to 12 zones expandable up to 492 zones. The rate shall include 2x500W Power Amplifire 1set (Equivalent of Bosch PVA-2P500 Power amplifier)

1

-

-

... More
Supply,installation ,testing & Commissioning of voice Alarm Call Station having gooseneck condenser Microphone with 8 zone Selection Keys along with expansion keypad to cater 45 zones and an All-Call-Key, PTT Switch, selectable gain, speech filter and limiter for improved intelligibility,built in speaker for audio channel monitoring,LED indication for zone selection complete as required

1

-

-

... More
Supply and laying of 2C 1.5 sqmm, Multistranded Copper, FRLS, Sheilded, Twisted Pair , Armoured cable.

2200

-

-

... More
LIFT AND ESCALATOR WORKS

-

-

-

... More
SITC of Electric Traction Service/Passenger Lift(1) with ·       Rated capacity :- 20 Passenger/1360Kg ·       Floors :- LG+UG+5 floors (7 Stops/7 Landings) ·       Travel :- 17.1 Mtrs ·       Location of Lift Machine:- MRL ·       Rated speed :- 1.0mps VS ·       Car/Landing door clear opening of 1100/1200 mm wide x 2000 mm high ·       Clear Car size of ......mm wide x ......mm deep x 2250mm high ·       Lift shaft available having clear size of 2300mm wide x 3000mm deep, 1800mm Pit depth, 4800mm Overhead. ·       Doors type :- COPO/TOPO Doors with frame made from SS 304 grade solid(non-cladded) sheet of 1.25mm thick in hairline finish for car and all landing doors with SS door architraves/frames The lift doors shall have minimum 1 hour fire rating (with submission of necessary valid test certificate issued by NABL accredited or Independent test laboratory). ·       Lift car enclosure made from SS 304 grade solid (non-cladded) sheet of 1.25mm, thick with hairline finish with frame made from MS girders, bracing of adequate size with minimum safety factor of 5, with Toe Guard Apron, with necessary false ceiling with adequate LED lights(Automatic), blower/fan(impulse and Automatic) for ventilation & Granite flooring/PVC flooring/SS chequered plate flooring, Rear Side-handrails, Rear Side-mirror, emergency light etc. Full Height Infrared Curtain of light in the car.Car Door Lock.Nudging Service.Single Phase Failure Sensing Device.Attendant Service.Accurate Relevelling.The lift car interior design shall be done as per the directions of engineer in charge. ·       COP with SS face plate having metallic push buttons with Braille code & luminous indicator around button with FPI, scrolling UP/DN LED indicator & with / without attendant key switch, OWD with audio-visual alarm, VAS in Marathi, Hindi & English with intercom system with telephone instrument in Lift car, LMR & FCC/ground floor. ·       LOP with SS face plate having recess/surface push button box for all landings with scrolling UP/DN LED indicator having metallic push buttons with Braille code & luminous indicator around button with CPI, Lift car arrival & next travel direction audio-visual indication at all landings.· Lift controller of Simplex full collective based on microprocessor/ PLC with VVVF Drive having closed loop control system, with IBMS compatible having necessary port. The controller shall have necessary protections such as overcurrent, overvoltage, over speed, overheat for all devices including lift motor and travel direction protection, protection for phase loss at input or output etc. ,various operation modes such as maintenance, change direction by attendant, full load bypass, VIP call operation, self levelling operation, call cancel facility, auto return to home landing, fireman evacuation operation, earthquake operation, door open/close operation from COP etc. The system can record information for minimum 30 latest faults, with real-time clock management and handheld keypad with LCD screen for view and setting of parameters. The control panel duly wired with proper size & strength, copper wire for power & control circuit, with provision for addition of floor/control card & allied accessories control panel having enclosure of 1.6mm CRCA sheet with powder coating with IP54 Protection class.·       ARD complete with necessary SMF VRLA batteries. ·       Fireman controller having fireman switch at fire Landing/at Upper Ground floor.CCTV surveillance system comprises of 2nos minimum 2.0MP FHD IP based vandal proof Dome camera in lift car & in LMR/inside lift shaft top aimed on Lift machinery & controller with NVR kept in LMR/FCC .Lift Machine of Gearless PMSM of suitable kW with duty cycle of minimum 120 starts/hr (with submission of necessary valid test certificate issued by NABL accredited or Independent test laboratory), with Traction pulley, OSG, electromagnetic brakes, entire assembly mounted on adequate size girders duly fixed on LMR floor/ shaft walls complete with main/diverter traction sheaves, suspension wire ropes/belts of adequate size & strength.     .   Other mechanical parts such as 'T' section adequate size guide rails for car & counter weight with brackets fasteners, counter weight frame with necessary blocks, buffers with necessary support arrangement, MS pit ladder etc. erected with necessary steel work.+C18 ·       Minor civil work such as alteration work if any necessary for erection of landing door frames and it's accessories e.g. sill, header, hole pass etc complete with plaster finish, civil work for erection buffers, erection of lift machinery, adequate size core cuts if required & scaffolding for erecting guide rails, providing and fixing steel girders/RCC work having adequate strength for mounting and hoisting lift machine etc. complete as per specification no. LFT. · General: - Job includes entire procedure of obtaining all necessary erection permissions & "License to Work the Lift" from Electrical Inspector(Lifts) with submission to the Engineer In Charge. · The above rate includes Fully Comprehensive AMC for one year from the date of commissioning.

6

-

-

... More
SITC of Electric Traction Service Lift with ·       Rated capacity :- 15 Passenger/1020Kg ·       Floors :- LG+UG+5 floors (7 Stops/7 Landings) ·       Travel :- 17.1 Mtrs ·       Location of Lift Machine:- MRL ·       Rated speed :- 1.0mps VS · Car/Landing door clear opening of 800/900/1000 mm wide x 2000mm high ·       Clear Car size of ......mm wide x ......mm deep x 2250mm high ·       Lift shaft available having clear size of 2100mm wide x 3000mm deep, 1600mm Pit depth, 4800mm Overhead.·       Doors type :- COPO/TOPO Doors with frame made from SS 304 grade solid(non-cladded) sheet of 1.25mm thick in hairline finish for car and all landing doors with SS door architraves/frames The lift doors shall have minimum 1 hour fire rating (with submission of necessary valid test certificate issued by NABL accredited or Independent test laboratory). ·       Lift car enclosure made from SS 304 grade solid (non-cladded) sheet of 1.25mm, thick with hairline finish with frame made from MS girders, bracing of adequate size with minimum safety factor of 5, with Toe Guard Apron, with necessary false ceiling with adequate LED lights(Automatic), blower/fan(impulse and Automatic) for ventilation & Granite flooring/PVC flooring/SS chequered plate flooring, Rear Side-handrails, Rear Side-mirror, emergency light etc. Full Height Infrared Curtain of light in the car.Car Door Lock.Nudging Service.Single Phase Failure Sensing Device.Attendant Service.Accurate Relevelling.The lift car interior design shall be done as per the directions of engineer in charge.·       COP with SS face plate having metallic push buttons with Braille code & luminous indicator around button with FPI, scrolling UP/DN LED indicator & with / without attendant key switch, OWD with audio-visual alarm, VAS in Marathi, Hindi & English with intercom system with telephone instrument in Lift car, LMR & FCC/ground floor. ·       LOP with SS face plate having recess/surface push button box for all landings with scrolling UP/DN LED indicator having metallic push buttons with Braille code & luminous indicator around button with CPI, Lift car arrival & next travel direction audio-visual indication at all landings.· Lift controller of Duplex full collective based on microprocessor/ PLC with VVVF Drive having closed loop control system, with IBMS compatible having necessary port. The controller shall have necessary protections such as overcurrent, overvoltage, over speed, overheat for all devices including lift motor and travel direction protection, protection for phase loss at input or output etc. ,various operation modes such as maintenance, change direction by attendant, full load bypass, VIP call operation, self levelling operation, call cancel facility, auto return to home landing, fireman evacuation operation, earthquake operation, door open/close operation from COP etc. The system can record information for minimum 30 latest faults, with real-time clock management and handheld keypad with LCD screen for view and setting of parameters. The control panel duly wired with proper size & strength, copper wire for power & control circuit, with provision for addition of floor/control card & allied accessories control panel having enclosure of 1.6mm CRCA sheet with powder coating with IP54 Protection class.        ARD complete with necessary SMF VRLA batteries. ·       Fireman controller having fireman switch at fire Landing/at Upper Ground floor.CCTV surveillance system comprises of 2nos minimum 2.0MP FHD IP based vandal proof Dome camera in lift car & in LMR/inside lift shaft top aimed on Lift machinery & controller with NVR kept in LMR/FCC .Lift Machine of Gearless PMSM of suitable kW with duty cycle of minimum 120 starts/hr (with submission of necessary valid test certificate issued by NABL accredited or Independent test laboratory), with Traction pulley, OSG, electromagnetic brakes, entire assembly mounted on adequate size girders duly fixed on LMR floor/ shaft walls complete with main/diverter traction sheaves, suspension wire ropes/belts of adequate size & strength.      .   Other mechanical parts such as 'T' section adequate size guide rails for car & counter weight with brackets fasteners, counter weight frame with necessary blocks, buffers with necessary support arrangement, MS pit ladder etc. erected with necessary steel work.+C18 ·       Minor civil work such as alteration work if any necessary for erection of landing door frames and it's accessories e.g. sill, header, hole pass etc complete with plaster finish, civil work for erection buffers, erection of lift machinery, adequate size core cuts if required & scaffolding for erecting guide rails, providing and fixing steel girders/RCC work having adequate strength for mounting and hoisting lift machine etc. complete as per specification no. LFT. · General: - Job includes entire procedure of obtaining all necessary erection permissions & "License to Work the Lift" from Electrical Inspector(Lifts) with submission to the Engineer In Charge. · The above rate includes Fully Comprehensive AMC for one year from the date of commissioning.

2

-

-

... More
SITC of Indoor Escalator for Passenger (From Ground to First floor) in Upward direction (Mention escalator is adjacent to another escalator) *Vertical Rise – 3600 mm *Max. Load(Person Per Hour) -6000 to 8000 .*Drive System- VVVF Drive .*Degree of inclination  -35 degrees .*Step width =1000mm. *Pit at lower end of escalator =1150 to 1200 mm from FFL. *Speed =0.5 m/s. *Horizontal Step- 2 flat steps * 415V, 50Hz,Three Phase Supply,5.5 or higher kW Motor  and 220/240V, 50Hz,Single Phase Supply,2.2kVA Illumination Power(For Skirting & Handrail Illumination -Includes Comb lighting). *Handrail in stainless steel finish(with Colour options).* Balustrade Profile/Cladding-S.S. Hairline Finish *Balustrade Panel - Tempered Safety Glass 10 mm *Balustrade height -1000 mm

2

-

-

... More
SITC of Indoor Escalator for Passenger (From Ground to First floor) in Downward direction (Mention escalator is adjacent to another escalator) *Vertical Rise – 3600 mm *Max. Load(Person Per Hour) -6000 to 8000 .*Drive System- VVVF Drive .*Degree of inclination  -35 degrees .*Step width =1000mm. *Pit at lower end of escalator =1150 to 1200 mm from FFL. *Speed =0.5 m/s. *Horizontal Step- 2 flat steps * 415V, 50Hz,Three Phase Supply,5.5 or higher kW Motor  and 220/240V, 50Hz,Single Phase Supply,2.2kVA Illumination Power(For Skirting & Handrail Illumination -Includes Comb lighting). *Handrail in stainless steel finish(with Colour options). * Balustrade Profile/Cladding-S.S. Hairline Finish *Balustrade Panel -Tempered Safety Glass 10 mm *Balustrade height -1000 mm

2

-

-

... More
FIRE FIGHTING WORKS

-

-

-

... More
Supplying, installation, testing and commissioning of Main Fire Pump (MFP / EP) suitable for water discharge of 2280 LPM/ 137 CuM/Hr at 100 m head driven by electric motor 415 volts, 3 phase 50 Hz, AC supply of 45 kW capacity for manual/ automatic operation and consisting of following: (a) Horizontal type, single stage, centrifugal/ split casing pump of cast iron body & bronze impeller with stainless steel shaft (SS410 grade), mechanical seal conforming to IS 1520. (b) Squirrel cage induction motor, TEFC, synchronous speed 2900 RPM, suitable for operation with IP 55 protection for enclosure, horizontal foot mounted type with Class-'F' insulation, conforming to IS-325. (c) M.S. fabricated common base plate, coupling, coupling guard, foundation bolts, matching hardware, matching suction & delivery flanges/ gaskets, etc. as required. (d) Erected on provided suitable size cement concrete foundation duly plastered with anti vibration pads with perfect aligning, proper levelling complete pump set with accessories duly painted with two coats of synthetic enamel paint of fire red colour over a coat of primer (ISC code 536 as per IS 2932 of 2003) complete, Refer Technical Specifications

2

-

-

... More
Supplying, installation, testing and commissioning of main fire pump suitable for water discharge of 2280 LPM at 100 m head driven by 75 HP or suitable HP capacity diesel engine at 2000 RPM working speed suitable for manual/automatic operation and consisting of following : (a) Horizontal type, single stage, centrifugal casing pump of cast iron body & bronze impeller with stainless steel shaft (SS410 grade), mechanical seal conforming to IS 1520. (b) Water cooled with radiator, diesel engine conforming to relevant IS standard complete with auto starting mechanism, 12 volts DC electric starting equipment with battery of required AH capacity with necessary charger suitable to work on 230v, 50Hz AC supply, diesel tank of minimum 150 ltr capacity with first filling of diesel up to 100% level with necessary piping with valves up to engine , exhaust pipe extended up to 10 m outside pump house duly insulated with 50 mm thick glass wool with 1.0 mm thick aluminium sheet cladding, residential silencer, instruments and protection as per standard specification, stop solenoid for auto stop in the event of fault with audio indications etc. as required. (c) M.S. fabricated common base plate, coupling, coupling guard, foundation bolts etc. as required. (d) Erected on provided suitable size cement concrete foundation duly plastered with anti vibration pads with perfect aligning, proper levelling complete pump set with engine assembly and accessories duly painted with two coats of synthetic enamel paint of fire red colour over a coat of primer (ISC code 536 as per IS 2932 of 2003) complete.

1

-

-

... More
Supplying, installing, testing & commissioning of fabricated Diesel Engine Pump Fuel Oil Day Tank from 3 mm MS sheet and 24G secondary containment as per IS:2552 of 300 liters gross capacity & 250 liters fill capacity, externally painted with two coats of synthetic enamel paint over a coat of primer & internally with oil resistant paint. The tank shall be fitted with clear glass oil level indicator, inspection hole with cover, drain valve, air vent including structural supports (painted with approved shade) for tank and fill/ return/ drain connection valves, etc. Refer Technical Specifications

1

-

-

... More
Providing & fixing, joining & testing, of heavy class-C M.S pipe IS:1239 marked in exhaust line of 100 mm dia. Diesel pump set, including cutting, welding etc. with MS butt welded fittings, providing clamp sand proper positioning of silencer and expansion bellows with nut-bolts as required, painting the finished pipeline with heat resistant Aluminum paint and providing lagging with 50 mm thick glass wool duly secured with chicken mesh and wire. Refer Technical Specifications

20

-

-

... More
Supplying, installation, testing and commissioning of jockey fire pump suitable for water discharge of 180 LPM at 70 m head driven by electric motor 415 volts, 3 phase 50 Hz, AC supply of 7.5 kW capacity for manual/ automatic operation and consisting of following : (a) Horizontal type, multi stage, end suction, back pull out, centrifugal casing pump of cast iron body & bronze impeller with stainless steel shaft (SS410 grade), mechanical seal conforming to IS 1520. (b) Squirrel cage induction motor, TEFC, synchronous speed 2900 RPM, suitable for operation with IP 55 protection for enclosure, horizontal foot mounted type with Class-'F' insulation, conforming to IS-325. (c) M.S. fabricated common base plate, coupling, coupling guard, foundation bolts etc. as required. (d) Erected on provided suitable size cement concrete foundation duly plastered with anti vibration pads with perfect aligning, proper levelling complete pump set with accessories duly painted with two coats of synthetic enamel paint of fire red colour over a coat of primer (ISC code 536 as per IS 2932 of 2003) complete.

2

-

-

... More
Supplying, installing, testing & commissioning of GI ERW of 200 mm dia. pipe as per IS:3589, Grade FE410, including all fittings. including fabrication of pipe in lengths to suit site condition & welding including providing rectifier welding machines with approved make electrodes, all fittings & above ground erection in shaft/ along the wall/ column, duly clamped with M12 U bolts on vertical or horizontal runs & hydrotesting at 1.5 x working pressure and commissioning after painting with flow directions marking on pipes. Refer Technical Specifications Refer Technical Specifications

22

-

-

... More
Supplying, installing, testing & commissioning of GI ERW following pipes, IS 1239 Part-1, Heavy duty, Class `C', including all fittings. including fabrication of pipe in lengths to suit site condition & welding including providing rectifier welding machines with approved make electrodes, all fittings & above ground erection in shaft/ along the wall/ column, duly clamped with M12 U bolts on vertical or horizontal runs & hydrotesting at 1.5 x working pressure and commissioning after painting with flow directions marking on pipes. Refer Technical Specifications 150 mm dia

365

-

-

... More
Supplying, installing, testing & commissioning of GI ERW following pipes, IS 1239 Part-1, Heavy duty, Class `C', including all fittings. including fabrication of pipe in lengths to suit site condition & welding including providing rectifier welding machines with approved make electrodes, all fittings & above ground erection in shaft/ along the wall/ column, duly clamped with M12 U bolts on vertical or horizontal runs & hydrotesting at 1.5 x working pressure and commissioning after painting with flow directions marking on pipes. Refer Technical Specifications 80 mm dia

35

-

-

... More
Supplying, installing, testing & commissioning of GI ERW following pipes, IS 1239 Part-1, Heavy duty, Class `C', including all fittings. including fabrication of pipe in lengths to suit site condition & welding including providing rectifier welding machines with approved make electrodes, all fittings & above ground erection in shaft/ along the wall/ column, duly clamped with M12 U bolts on vertical or horizontal runs & hydrotesting at 1.5 x working pressure and commissioning after painting with flow directions marking on pipes. Refer Technical Specifications 50 mm dia

15

-

-

... More
Supplying, installing, testing & commissioning of Red Oxide primer (10 SqM per Ltr 25 micron DFT). For above ground piping, Application of including provision of hand tool for surface cleaning & brush for application of primer in 2 coats each of 25 micron DFT, satisfaction of Engineer-in-Charge.

42.6

-

-

... More
Supplying, installing, testing & commissioning of Synthetic enamel finish paint shade 536 in IS 5 (13.5 sqM per Ltr-25 micron). For Above ground piping. Brush for application of final paint compatible with primer in 2 coats each of 25 micron DFT, satisfaction of Engineer-in-Charge.

34.22

-

-

... More
Supplying, installing, testing and commissioning of Rubber Expansion Bellows of following sizes for water media, EPDM/ Nitrile material, flange connection, dual arch, suitable for up to 70 deg C temp., Axial/ Lateral/ Torsional- flexibility, pressure range-16 Mpa including nuts, bolts and washers complete as required. complete as directed & specified as per the direction of engineer in charge. Refer Technical Specifications 200 mm dia.

3

-

-

... More
Supplying, installing, testing and commissioning of Rubber Expansion Bellows of following sizes for water media, EPDM/ Nitrile material, flange connection, dual arch, suitable for up to 70 deg C temp., Axial/ Lateral/ Torsional- flexibility, pressure range-16 Mpa including nuts, bolts and washers complete as required. complete as directed & specified as per the direction of engineer in charge. Refer Technical Specifications 150 mm dia.

3

-

-

... More
Supplying, installing, testing and commissioning of Rubber Expansion Bellows of following sizes for water media, EPDM/ Nitrile material, flange connection, dual arch, suitable for up to 70 deg C temp., Axial/ Lateral/ Torsional- flexibility, pressure range-16 Mpa including nuts, bolts and washers complete as required. complete as directed & specified as per the direction of engineer in charge. Refer Technical Specifications 80 mm dia

2

-

-

... More
Supplying, installing, testing and commissioning of Rubber Expansion Bellows of following sizes for water media, EPDM/ Nitrile material, flange connection, dual arch, suitable for up to 70 deg C temp., Axial/ Lateral/ Torsional- flexibility, pressure range-16 Mpa including nuts, bolts and washers complete as required. complete as directed & specified as per the direction of engineer in charge. Refer Technical Specifications 50 mm dia.

2

-

-

... More
Supplying, installing, testing & commissioning of Lever operated Leak Proof Wafer type C.I. Butterfly Valve PN 16 class, with CI260/SGI IS 1865-400/15 Body & seat, EPDM Body lining, SS IS 6603 Gr12 Cr 12 shaft, conforming to IS 13095 / BS 593 of following sizes. including provision & welding of matching flange to BS 10 Table D, providing fasteners to IS nut bolts to IS 1363 PT1 Class 4.62, gaskets to IS 638 Type 2, with tag nos as per P & ID. Refer Technical Specifications 200 mm dia

3

-

-

... More
Supplying, installing, testing & commissioning of Lever operated Leak Proof Wafer type C.I. Butterfly Valve PN 16 class, with CI260/SGI IS 1865-400/15 Body & seat, EPDM Body lining, SS IS 6603 Gr12 Cr 12 shaft, conforming to IS 13095 / BS 593 of following sizes. including provision & welding of matching flange to BS 10 Table D, providing fasteners to IS nut bolts to IS 1363 PT1 Class 4.62, gaskets to IS 638 Type 2, with tag nos as per P & ID. Refer Technical Specifications 150 mm dia.

5

-

-

... More
Supplying, installing, testing & commissioning of Lever operated Leak Proof Wafer type C.I. Butterfly Valve PN 16 class, with CI260/SGI IS 1865-400/15 Body & seat, EPDM Body lining, SS IS 6603 Gr12 Cr 12 shaft, conforming to IS 13095 / BS 593 of following sizes. including provision & welding of matching flange to BS 10 Table D, providing fasteners to IS nut bolts to IS 1363 PT1 Class 4.62, gaskets to IS 638 Type 2, with tag nos as per P & ID. Refer Technical Specifications 100 mm dia.

3

-

-

... More
Supplying, installing, testing & commissioning of Lever operated Leak Proof Wafer type C.I. Butterfly Valve PN 16 class, with CI260/SGI IS 1865-400/15 Body & seat, EPDM Body lining, SS IS 6603 Gr12 Cr 12 shaft, conforming to IS 13095 / BS 593 of following sizes. including provision & welding of matching flange to BS 10 Table D, providing fasteners to IS nut bolts to IS 1363 PT1 Class 4.62, gaskets to IS 638 Type 2, with tag nos as per P & ID. Refer Technical Specifications 80 mm dia.

2

-

-

... More
Supplying, installing, testing & commissioning of Lever operated Leak Proof Wafer type C.I. Butterfly Valve PN 16 class, with CI260/SGI IS 1865-400/15 Body & seat, EPDM Body lining, SS IS 6603 Gr12 Cr 12 shaft, conforming to IS 13095 / BS 593 of following sizes. including provision & welding of matching flange to BS 10 Table D, providing fasteners to IS nut bolts to IS 1363 PT1 Class 4.62, gaskets to IS 638 Type 2, with tag nos as per P & ID. Refer Technical Specifications50 mm dia.

2

-

-

... More
Supplying, installing, testing & commissioning of double flange Non Return Valve PN 16 class of following sizes Conforming to IS: 5312 (Part-I), Universal mounting (Hroz/ Vert) having CI to IS 210Gr260 Body and Bronze IS318 Gr LTB Disc with nut bolts to IS 1363 PT1 Class 4.6, Matching flanges to BS 10 Table D, Gaskets & Body ring Nitrile to IS:638 Type B, fasteners, etc. and tested to 1.5 times of working pressure in an approved manner, with tag nos as per P & ID. Refer Technical Specifications 150 mm dia.

3

-

-

... More
Supplying, installing, testing & commissioning of double flange Non Return Valve PN 16 class of following sizes Conforming to IS: 5312 (Part-I), Universal mounting (Hroz/ Vert) having CI to IS 210Gr260 Body and Bronze IS318 Gr LTB Disc with nut bolts to IS 1363 PT1 Class 4.6, Matching flanges to BS 10 Table D, Gaskets & Body ring Nitrile to IS:638 Type B, fasteners, etc. and tested to 1.5 times of working pressure in an approved manner, with tag nos as per P & ID. Refer Technical Specifications 100 mm dia.

2

-

-

... More
Supplying, installing, testing & commissioning of double flange Non Return Valve PN 16 class of following sizes Conforming to IS: 5312 (Part-I), Universal mounting (Hroz/ Vert) having CI to IS 210Gr260 Body and Bronze IS318 Gr LTB Disc with nut bolts to IS 1363 PT1 Class 4.6, Matching flanges to BS 10 Table D, Gaskets & Body ring Nitrile to IS:638 Type B, fasteners, etc. and tested to 1.5 times of working pressure in an approved manner, with tag nos as per P & ID. Refer Technical Specifications50 mm dia.

3

-

-

... More
Supplying & installing gun metal Gate Valve of 50 mm dia. having threaded ends, conforming to IS: 778, ISI mark, along with G.I. threaded nipple. Refer Technical Specifications

2

-

-

... More
Supplying, installing, testing & commissioning of PN 16 Cast Iron, factory made, flanged Y type strainer of 200 mm NB with SS 304 strainer having 3 mm holes with companion flange set of 2 flanges to IS 1538 and including welding of matching flange BS 10 Table D & providing fasteners to IS 1363 grade 5.6/8.8 & rubber gaskets to IS 2172 grade W/3 with standard OAR (open area ratio) for positive suction complete. Refer Technical Specifications

2

-

-

... More
Supplying and installing Air Vessel of 300 mm dia and 1.5 mtr. in height M.S. Tank fabricated from M.S. black ERW pipe, conforming to I.S.: 3589, having 6 mm thickness, dish end at both ends, duly welded with 300 mm dia pipe, having inlet of 100 mm dia, duly fitted with 100 mm dia sluice valve and 20/25 mm dia draw in with G.M. gate valve, to be installed inside pump house along with provided M.S. angle (75 x 75 x 5 mm) tripod.

2

-

-

... More
Supplying, installing, testing & commissioning of GM body and inlet in CI, 2 way Fire Brigade connection with NRV of 7 kG/cm2 working pressure and test pressure 10.5 kG/cm2, Header of 100 mm dia, M.S. ‘C’ class pipe having 2 Nos. of 100 mm manifold for outlets with built in spring loaded NRV & 100 nb butterfly Isolation valve with 100 mm dia flange, fitted with 2 nos. of 63 mm diameter instantaneous male inlet connection is provided at street level and connected to Fire UG tank for draw out connection, complete with Matching flanges to BS 10 Table D, Gaskets & Body ring Nitrile to IS:638 Type B, fasteners, etc Refer Technical Specifications

1

-

-

... More
Supplying, installing, testing & commissioning of GM body and inlet in CI, 4 way Fire Brigade Inlet connection with NRV of 7 kG/cm2 working pressure and test pressure 10.5 kG/cm2, Header of 150 mm dia, M.S. ‘C’ class pipe having 4 Nos. of 150 mm manifold for outlets with built in spring loaded NRV & 150 NB butterfly Isolation valve with 150 mm dia flange, fitted with 4 nos. of 63 mm diameter instantaneous male inlet connection is provided at street level and connected to Fire UG tank for fill the tank, complete with Matching flanges to BS 10 Table D, Gaskets & Body ring Nitrile to IS:638 Type B, fasteners, etc Refer Technical Specifications

1

-

-

... More
Supplying, installing, testing & commissioning of UL/ FM approved Pressure Gauge of 100 mm dia., liquid filled 0-10 bar. Fitted with 15 mm dia. root cock valve, and G.I. pipe, elbow, snubber, process piping etc. as per requirement in an approved manner. Refer Technical Specifications

7

-

-

... More
Supplying, installing, testing & commissioning of UL/ FM approved Pressure Switch for pump control with 2 NO + 2 NC contacts, 12/15 mm dia. process connection for 3Cx1.5 sqmm cable, operation range 0-10 bar, with 12/15 mm dia. root valve, G.I. nipple, elbow, snubber, process piping etc. in an approved manner. Refer Technical Specifications

5

-

-

... More
Supplying & installing of ABC Powder Cartridge Portable Fire extinguisher 6 kg capacity (21B), 35 bar Test / 15 Bar working, 4.5 M throw, 20 second discharge time, Propellant CO2 in gas cartridge, charge as per IS 4308, MS sheet deep drawn steel cylinder, sqeeze grip brass control valve, AL syphon tube, Non metallic discharge nozzle, 450 mm long PVC braided hose, pressure gauge, hose holder, conforming to IS 15683 / IS 2190:2010, portable at appointed location on wall/ column mounted brackets, clamps & other accessories. Refer Technical Specifications

1

-

-

... More
Supplying & erecting of CO2 type extinguisher, 4.5 kg capacity (21B), 250 Bar Test / 60 Bar storage, 2M min throw, 12 second discharge time, Propellant CO2 in gas cartridge, charge as per IS 15222, Seamless steel tube cylinder to IS 7285, sqeeze grip brass control valve to IS 3224, AL internal discharge tube, Poly Ethylene discharge nozzle, 450 mm long PVC braided hose, safety release, seal temper indicator, pressure gauge, hose holder & conforming to IS 15683 /IS 2190:2010. portable at appointed location on wall/ column mounted brackets, clamps & other accessories. Refer Technical Specifications

1

-

-

... More
ELECTRICAL FIRE PANEL Supply, Installation, Testing & Commissioning of Fire LT Panels front operated dust and vermin proof power cum control panel comprising below points. 1)-Panels shall be fabricated out of 16/14 swg CRCA sheet steel, with necessory structural supports in form of structural steel sections. 2)-Floor mounted, IP-54 degree protection, Top cable entry/exit as per the case steel, 2mm frame, 1.6 mm compartments & one coat of primer & painted in RED colour. 3)-The panel shall be compartmental, Form 3B type, with suitable size of bus bar and separate cable and busbar chambers. 4)-Providing suitable number of switchgears, busbars, auxilliary switches, audio alarm hooters, visual indications, relays, contactors, timers of suitable capacity for automatic operation of pumps i/c. connections and all connected accessories. Indicating lamps should be of LED type as per the Single line diagram. 5)-Proper gland size holes to be provided by the manufacturer with proper sticker and danger sign on all sides of panel. 6)-The cable chambers shall be free from any live open connections and minimum cleareance to be provided for termination. 7) Electrolytic Aluminum busbars grade E91E to IS 5082, 1 A/Sqmm,1100 V grade insulation, 25 kA for 1 sec, (IS-8623 for factory built assembly). 7)- Earthing terminal at both end. 9) Powder coating of approved color shade on both sides of provided iron work / MS / CRCA sheet steel work complete including anti-rust treatment - (7 Tank process) in an approved manner. 10) Includes coordination & setting of all swtchgear with upstream & downstream switchgear. 11) Panel stand as per site conditions is in contractor scope of work. All pumps automatic control on pressure, as per local Fire norms, IS standards should be in contrcator scope of work. (Including following items of 32 & 32.1 to 32.7)) Incoming 250A TPN 36kA MCCB TM Released with adjustable thermal & magnetic settings. Manual operated front rotary operated handle with R-Y-B-R-G-A lamps, with 3x metering CTs, digital MFM (with A,V, kWh Reading facility) Bus-bar 250 A TPN , AI. Busbar, Suitable for 35kA/1sec Outgoing 7.5 kW Y/Δ starter for Jockey pump with 20 A TPN MCB+25A Line Contactor+ 25A Delta contactor+12 A star contactor + 7A-10 A Relay,  Thermal O/L, A/M selector, presure switch based On and Off control, R/G/A indication lamps 45 kW Y/Δ starters eletrical hydrant with 100 A MCCB TM Released with adjustable thermal & magnetic settings + Line contactor-185A, Delta contactor-185A, Star contactor-32 A, 45A-63 Relay Thermal O/L, A/M selector,Pressure switch operated On & Manual Off with R/G/A indication lamps.55 kW Y/Δ starters sprinkler pump with 100 A MCCB TM Released with adjustable thermal & magnetic settings + Line contactor-185A, Delta contactor-185A, Star contactor-32 A, 45A-63 Relay Thermal O/L, A/M selector,Pressure switch operated On & Manual Off with R/G/A indication lamps. 20A 10kA SPN MCB-Spare 40A 16kA TPN MCCB-Spare Engine control module comprising - step down transformer & solid state  electronic automatic trickle / boost battery charger for engine starting battery 160 AH12 V or 24V battery as per engine requirement & microprocessor based electronic controller for HWT/OSR/LOP protection & cranking signal timer of adjustable 15 sec ON+15 Sec OFF with supervisory timer for 5 start attempt cranking fail with ACV/DCV/DCA meters, Normal/Abnormal indications,Audio Visual annunciation of faults, A/M selector, pressure switch operated On & Manual Off. Supply Cables Supply of 3 core armoured PVC/XLPE insulated, PVC sheathed aluminium conductor cable of 1.1 KV grade with ISI mark conforming to IS:1554(Part I) ,IS:7098(Part I) with latest amendments of following size.

1

-

-

... More
Supply of 3 core armoured PVC/XLPE insulated, PVC sheathed aluminium conductor cable of 1.1 KV grade with ISI mark conforming to IS:1554(Part I) ,IS:7098(Part I) with latest amendments of following size. 3 Core 150 sq.mm

60

-

-

... More
Supply of 3 core armoured PVC/XLPE insulated, PVC sheathed aluminium conductor cable of 1.1 KV grade with ISI mark conforming to IS:1554(Part I) ,IS:7098(Part I) with latest amendments of following size. 3 Core 2.5 Sq.mm

50

-

-

... More
Supply of 3 core armoured PVC/XLPE insulated, PVC sheathed aluminium conductor cable of 1.1 KV grade with ISI mark conforming to IS:1554(Part I) ,IS:7098(Part I) with latest amendments of following size. 3 Core 4 Sq.mm

25

-

-

... More
Supply of 4 core unarmoured PVC/XLPE insulated, PVC sheathed aluminium conductor cable of 1.1 KV grade with ISI mark conforming to IS:1554(Part I) ,IS:7098(Part I) with latest amendments of following size. 4 Core 4 Sq.mm

50

-

-

... More
Supply of 4 core unarmoured PVC/XLPE insulated, PVC sheathed aluminium conductor cable of 1.1 KV grade with ISI mark conforming to IS:1554(Part I) ,IS:7098(Part I) with latest amendments of following size. 4 Core 6 Sq.mm

100

-

-

... More
Cable Gland Nickel plated single compresion type 1-1/2"

6

-

-

... More
Cable Gland Nickel plated single compresion type 1-1/4"

12

-

-

... More
Supplying and Installing following size perforated type 16 SWG, M.S.cable tray of GI pregalvanised/hot dip galvanised/ powder coated finish, in convenient sections, joined with connectors, suspended from the ceiling with suitable MS suspenders including bolts and nuts, painting suspenders etc, complete as required. 300 mm width 50 mm depth

12

-

-

... More
Supplying and Installing following size perforated type 16 SWG, M.S.cable tray of GI pregalvanised/hot dip galvanised/ powder coated finish, in convenient sections, joined with connectors, suspended from the ceiling with suitable MS suspenders including bolts and nuts, painting suspenders etc, complete as required. 150 mm width 50 mm depth

12

-

-

... More
Supplying and Installing following size perforated type , M.S.cable tray bends of GI pregalvanised/hot dip galvanised/ powder coated finish, in convenient sections, joined with connectors, suspended from the ceiling with suitable MS suspenders including bolts and nuts, painting suspenders etc, complete as required. 300 mm width 50 mm depth

2

-

-

... More
Supplying and Installing following size perforated type , M.S.cable tray bends of GI pregalvanised/hot dip galvanised/ powder coated finish, in convenient sections, joined with connectors, suspended from the ceiling with suitable MS suspenders including bolts and nuts, painting suspenders etc, complete as required. 150 mm width 50 mm depth

2

-

-

... More
Supplying, fabricating & installing of M.S. Support, for MS piping supported on Brick wall/ RCC wall/ slab consisting with suitable size of mild steel angles, flat plate, channels, nut bolts etc..along with anchor, rod, etc. complete as per drawing.

50

-

-

... More
Supplying, Installing, Testing and Commissioning of Dial type water level indicator with potantial free contacts for underground RCC water tank up to 3.0 M depth comprising float in side a SS stilling well attached to SS rope & other end attached to drum with tensioned spring operating Red pointer thriugh a gear mechanism on powder coated Al dial with black graduations & numerals having 10mm accuracy complete with 2 nos 5A/230V AC adustable contacts & 4-20 mA transmitter with 2% accuracy.

1

-

-

... More
Supplying, installing, testing & commissioning of GI ERW following pipes, IS 1239 Part-1, Heavy duty, Class `C',For Above ground - fabrication of pipe in lengths to suit site condition & welding including providing rectifier welding machines with approved make electrodes, all fittings & above ground erection in shaft/ along the wall/ column, duly clamped with M12 U bolts on vertical or horizontal runs & hydrotesting at 1.5 x working pressure and commissioning after painting with flow directions marking on pipes. Refer Technical Specifications 150 mm dia

25

-

-

... More
Supplying, installing, testing & commissioning of GI ERW following pipes, IS 1239 Part-1, Heavy duty, Class `C',For Above ground - fabrication of pipe in lengths to suit site condition & welding including providing rectifier welding machines with approved make electrodes, all fittings & above ground erection in shaft/ along the wall/ column, duly clamped with M12 U bolts on vertical or horizontal runs & hydrotesting at 1.5 x working pressure and commissioning after painting with flow directions marking on pipes. Refer Technical Specifications 100 mm dia

85

-

-

... More
Supplying, installing, testing & commissioning of GI ERW following pipes, IS 1239 Part-1, Heavy duty, Class `C',For Above ground - fabrication of pipe in lengths to suit site condition & welding including providing rectifier welding machines with approved make electrodes, all fittings & above ground erection in shaft/ along the wall/ column, duly clamped with M12 U bolts on vertical or horizontal runs & hydrotesting at 1.5 x working pressure and commissioning after painting with flow directions marking on pipes. Refer Technical Specifications 80 mm dia

12

-

-

... More
Supplying, installing, testing & commissioning of GI ERW following pipes, IS 1239 Part-1, Heavy duty, Class `C',For Above ground - fabrication of pipe in lengths to suit site condition & welding including providing rectifier welding machines with approved make electrodes, all fittings & above ground erection in shaft/ along the wall/ column, duly clamped with M12 U bolts on vertical or horizontal runs & hydrotesting at 1.5 x working pressure and commissioning after painting with flow directions marking on pipes. Refer Technical Specifications 25 mm dia

18

-

-

... More
For underground, Fabrication of pipe in lengths to suit site condition & welding after bevelling pipes & using 3.15 mm electrode for root run & 2.5 mm for subsequent runs including taking & grinding including all fittings & providing rectifier welding machines with approved make electrodes, underground erection in excavated pipe trenches at 1M hydrotesting at 1.5 x working pressure before wrap coat & commissioning after 100% length holiday testing & radiography of 10% insitu joints subject to minimum 1. Refer Technical Specifications 150 mm dia

650

-

-

... More
For underground, Fabrication of pipe in lengths to suit site condition & welding after bevelling pipes & using 3.15 mm electrode for root run & 2.5 mm for subsequent runs including taking & grinding including all fittings & providing rectifier welding machines with approved make electrodes, underground erection in excavated pipe trenches at 1M hydrotesting at 1.5 x working pressure before wrap coat & commissioning after 100% length holiday testing & radiography of 10% insitu joints subject to minimum 1. Refer Technical Specifications 100 mm dia

70

-

-

... More
Supplying, installing, testing & commissioning of Bituminous Primer (200 gms/SqM). For under ground piping. Application of including provision of hand tool for surface cleaning & brush for application of primer.

66.63

-

-

... More
Supplying, installing, testing & commissioning of 2 mm thick tape to IS 10221 App B, tar based polymeric mix based on high tensile strength HMHDPE thermofusible material in 500 mm width. For Under ground piping. Application of including provision of LPG gas in cylinders & nozzle with piping, wrapping in 2 layers in oppostite direction with 15% overlap & thermal fusing in situ.

766.25

-

-

... More
Supplying, installing, testing & commissioning of Red Oxide primer (10 sqM per Ltr 25 micron DFT). For above ground piping, Application of including provision of hand tool for surface cleaning & brush for application of primer in 2 coats each of 25 micron DFT, satisfaction of Engineer-in-Charge.

9

-

-

... More
Supplying, installing, testing & commissioning of Synthetic enamel finish paint shade 536 in IS 5 (13.5 sqM per Ltr-25 micron). For Above ground piping. Brush for application of final paint compatible with primer in 2 coats each of 25 micron DFT, satisfaction of Engineer-in-Charge.

7

-

-

... More
Supplying, installing, testing & commissioning of Lever operated Leak Proof Wafer type C.I. Butterfly Valve PN10 class, with CI260/SGI IS 1865-400/15 Body & seat, EPDM Body lining, SS IS 6603 Gr12 Cr 12 shaft, conforming to IS 13095 / BS 5155 of following sizes, including provision & welding of matching flange to BS 10 Table D, providing fasteners to IS nut bolts to IS 1363 PT1 Class 4.62, gaskets to IS 638 Type 2, with tag nos as per P & ID. Refer Technical Specifications 150 mm dia

3

-

-

... More
Supplying, installing, testing & commissioning of Lever operated Leak Proof Wafer type C.I. Butterfly Valve PN10 class, with CI260/SGI IS 1865-400/15 Body & seat, EPDM Body lining, SS IS 6603 Gr12 Cr 12 shaft, conforming to IS 13095 / BS 5155 of following sizes, including provision & welding of matching flange to BS 10 Table D, providing fasteners to IS nut bolts to IS 1363 PT1 Class 4.62, gaskets to IS 638 Type 2, with tag nos as per P & ID. Refer Technical Specifications 100 mm dia

2

-

-

... More
Supplying, installing, testing & commissioning of forged brass 20 mm dia. Air Release Valve, 8.8 bar System pressure, full bore, forged brass body/ Chamber/ Cover- IS 6912 Gr. FLB, Float/ Lock/ Hinge/ Pin- Polypropylene, Spring SS304, Ring-Nitrile, Strainer-Plastic and with tag nos as per P & ID. Refer Technical Specifications

2

-

-

... More
Supplying & erecting of bronze Ball Valves of 25 mm dia., full bore, two pieces, Quarter turn, Mild Steel lever operated with tag nos as per P & ID. Refer Technical Specifications

12

-

-

... More
Supplying, installing, testing & commissioning of wall/ column/ ground mounted Outdoor/ Indoor Hose Cabinet of 16 gauge, CRCA sheet of 450mm x 450mm ht x 250mm suitable to house 1 no, 15 M hoses, branch pipe and nozzle with 4 mm thick glass visor, industrial key lock, chrome plated double leaf door handles, internal 2 coats of synthetic enamel white paint in 25 micron DFT each & 2 coats external synthetic enamel paint of 25 micron DFT in shade 536 of IS 5. The work includes Fabration & erection of ground mounted back frame steel structure or wall mounted with painting as also support grouting as per the site condition @ installing so that bottom of box is 900 mm above ground. Refer Technical Specifications

32

-

-

... More
Supplying, installing, testing & commissioning of SS Single Headed Hydrant Valve, oblique type single outlet, with a flow of 900 LPM @ 7 bar flow having 63 mm instantaneous female coupling outlet & fitted with accessories of cap, chain etc. to IS 5290. Single outlet hydrants on 80 nb @ height of 1.2 M above ground including providing & welding of matching flange to BS 10 Table F,providing fasteners to IS 1363 grade 5.6/8.8 & rubber gaskets to IS 2172 grade W/3. Refer Technical Specifications

32

-

-

... More
Supplying & installing wall mounting Swinging type Hose Reel Drum complete with hub, sides-powder coated finish in red, wall bracket made out of 16 guage CRCA sheet fitted with 19 mm dia, 30 m long rubber tubing confirming to IS 444 with 24 LPM flow & 6 M throw SS 304 jet nozzle to IS 8090 fitted with SS shut off valve to IS 778, fitted in wall/ structure as the case may be with fabration & erection of ground/ floor/ wall/ column mounted steel structure with painting. Refer Technical Specifications

12

-

-

... More
Supplying, installing, testing & commissioning of RRL hose pipes 63 mm dia, 15 m in length, Type-A, reinforced rubber lined, to IS 636 complete with male female instantaneous copper wire bound coupling of 63 nb size in SS 304 conforming to IS 903. hoses in external/ internal hose cabinet.

44

-

-

... More
Supplying, installing, testing & commissioning of SS 304 branch pipe of 63 mm x 42.5 fitted & to IS 903 with SS 304 Jet nozzle with 42.4 mm x 20 mm size having 6 M throw & to IS 903. branch pipe in external/ internal hose cabinet.

32

-

-

... More
Supplying, installing, testing & commissioning of GM body and inlet in CI, 4 way Fire Brigade connection with NRV of 7 kG/cm2 working pressure and test pressure 10.5 kG/cm2, Header of 150 mm dia, M.S. ‘C’ class pipe having 4 Nos. of 150 mm manifold for outlets with built in spring loaded NRV & 150 nb butterfly Isolation valve with 150 mm dia flange, fitted with 4 nos. of 63 mm diameter instantaneous male inlet connection is provided at street level and connected to Hydrant water header.

1

-

-

... More
Supplying, installing, testing & commissioning of GI ERW following pipes, IS 1239 Part-1, Heavy duty, Class `C', For Above ground - fabrication of pipe in lengths to suit site condition & welding including providing rectifier welding machines with approved make electrodes, all fittings & above ground erection in shaft/ along the wall/ column, duly clamped with M12 U bolts on vertical or horizontal runs & hydrotesting at 1.5 x working pressure and commissioning after painting with flow directions marking on pipes. Refer Technical Specifications 150 mm NB

190

-

-

... More
Supplying, installing, testing & commissioning of GI ERW following pipes, IS 1239 Part-1, Heavy duty, Class `C', For Above ground - fabrication of pipe in lengths to suit site condition & welding including providing rectifier welding machines with approved make electrodes, all fittings & above ground erection in shaft/ along the wall/ column, duly clamped with M12 U bolts on vertical or horizontal runs & hydrotesting at 1.5 x working pressure and commissioning after painting with flow directions marking on pipes. Refer Technical Specifications 100 mm NB

160

-

-

... More
Supplying, installing, testing & commissioning of GI ERW following pipes, IS 1239 Part-1, Heavy duty, Class `C', For Above ground - fabrication of pipe in lengths to suit site condition & welding including providing rectifier welding machines with approved make electrodes, all fittings & above ground erection in shaft/ along the wall/ column, duly clamped with M12 U bolts on vertical or horizontal runs & hydrotesting at 1.5 x working pressure and commissioning after painting with flow directions marking on pipes. Refer Technical Specifications 80 mm NB

280

-

-

... More
Supplying, installing, testing & commissioning of GI ERW following pipes, IS 1239 Part-1, Heavy duty, Class `C', For Above ground - fabrication of pipe in lengths to suit site condition & welding including providing rectifier welding machines with approved make electrodes, all fittings & above ground erection in shaft/ along the wall/ column, duly clamped with M12 U bolts on vertical or horizontal runs & hydrotesting at 1.5 x working pressure and commissioning after painting with flow directions marking on pipes. Refer Technical Specifications 65 mm NB

440

-

-

... More
Supplying, installing, testing & commissioning of GI ERW following pipes, IS 1239 Part-1, Heavy duty, Class `C', For Above ground - fabrication of pipe in lengths to suit site condition & welding including providing rectifier welding machines with approved make electrodes, all fittings & above ground erection in shaft/ along the wall/ column, duly clamped with M12 U bolts on vertical or horizontal runs & hydrotesting at 1.5 x working pressure and commissioning after painting with flow directions marking on pipes. Refer Technical Specifications 50 mm NB (threaded fittings)

450

-

-

... More
Supplying, installing, testing & commissioning of GI ERW following pipes, IS 1239 Part-1, Heavy duty, Class `C', For Above ground - fabrication of pipe in lengths to suit site condition & welding including providing rectifier welding machines with approved make electrodes, all fittings & above ground erection in shaft/ along the wall/ column, duly clamped with M12 U bolts on vertical or horizontal runs & hydrotesting at 1.5 x working pressure and commissioning after painting with flow directions marking on pipes. Refer Technical Specifications 40 mm NB (threaded fittings)

640

-

-

... More
Supplying, installing, testing & commissioning of GI ERW following pipes, IS 1239 Part-1, Heavy duty, Class `C', For Above ground - fabrication of pipe in lengths to suit site condition & welding including providing rectifier welding machines with approved make electrodes, all fittings & above ground erection in shaft/ along the wall/ column, duly clamped with M12 U bolts on vertical or horizontal runs & hydrotesting at 1.5 x working pressure and commissioning after painting with flow directions marking on pipes. Refer Technical Specifications 32 mm NB (threaded fittings)

510

-

-

... More
Supplying, installing, testing & commissioning of GI ERW following pipes, IS 1239 Part-1, Heavy duty, Class `C', For Above ground - fabrication of pipe in lengths to suit site condition & welding including providing rectifier welding machines with approved make electrodes, all fittings & above ground erection in shaft/ along the wall/ column, duly clamped with M12 U bolts on vertical or horizontal runs & hydrotesting at 1.5 x working pressure and commissioning after painting with flow directions marking on pipes. Refer Technical Specifications 25 mm NB (threaded fittings)

2710

-

-

... More
Supplying, installing, testing & commissioning of Red Oxide primer (10 SqM per Ltr 25 micron DFT). For above ground piping, Application of including provision of hand tool for surface cleaning & brush for application of primer in 2 coats each of 25 micron DFT, satisfaction of Engineer-in-Charge.

143

-

-

... More
Supplying, installing, testing & commissioning of Synthetic enamel finish paint shade 536 in IS 5 (13.5 sqM per Ltr-25 micron). For Above ground piping. Brush for application of final coat compatible with primer in 2 coats each of 25 micron DFT.

106

-

-

... More
Supplying, installing, testing & commissioning of Pendant/ Upright / Recessed, UL/FM certified, SRSC sprinklers, chrome finish, K-factor 80 @ 0.5 bar (2.25 LPM @ 84 SqM), Temperature 58 Deg C, 4.5M x 4.5M, 1/2" NPT, including olet fittings & rosette plates. Refer Technical Specifications

3151

-

-

... More
Supplying, installing, testing & commissioning of 150 mm dia. constant pressure Alarm Valve UL listed, flange x flange, suitable for vertical installation on Sprinkler riser, Housing/ Cover/ Clapper Ductile Iron, Seat SS, Gaskets/ Seat EPDM, body flanges drilled to ANSI 16.5 # 150 complete with hydraulic & alarm trim with matching flanged drilled to complete with Test & Alarm trim & providing & welding of matching flanges to BS10 Table D, providing fasteners to IS 1363 grade, 5.6/8.8 & rubber gaskets to IS 2172 grade W/3.

6

-

-

... More
Supplying, installing, testing & commissioning of Lever operated Leak Proof Wafer type C.I. Butterfly Valve PN10 class of 150 mm dia, with CI260/SGI IS 1865-400/15 Body & seat, EPDM Body lining, SS IS 6603 Gr12 Cr 12 shaft, conforming to IS 13095 / BS 5155, including provision & welding of matching flange to BS10 Table F, providing fasteners to IS nut bolts to IS 1363 PT1 Class 4.62, gaskets to IS 638 Type 2, with tag nos as per P & ID.

12

-

-

... More
Supplying, installing, testing & commisssioning of insertion type vane Flow Switch UL listed pipe insertion type suitable for 30 bar pressure for velocity up to 6 M/Sec, trigger flow of 15 LPM with IP 55 switch box having 2 SPDT contacts rated at 1.5 A, 24 V DC. complete with all accessories.

12

-

-

... More
Supplying, installing, testing and commissioning of Test and Drain valve of 50 mm dia threaded brass body, ball type, suitable to k-factor 80, sight glass, between sprinkler header & 50 mm dia. drainage line including piping connections, cutting, threading etc, complete as required.

12

-

-

... More
Supplying, installing, testing & commissioning of forged brass 20 mm dia. Air Release Valve, 8.8 bar System pressure, full bore, forged brass body/ Chamber/ Cover- IS 6912 Gr. FLB, Float/ Lock/ Hinge/ Pin- Polypropylene, Spring SS304, Ring-Nitrile, Strainer-Plastic.

2

-

-

... More
Supplying & erecting of bronze Ball Valves of 25 mm dia., full bore, two pieces, Quarter turn, Mild Steel lever operated.

2

-

-

... More
Supplying & installing of ABC Type Fire Extinguisher Cap. 6 kg Filled with Mono Ammonium Phosphate Powder 50% confirms to IS 4308, Stored Pressure Type, UGTS Pressure Gauge, Discharge Time 24 Sec, Controllable discharge mechanism, Jet Range 5 Meters, Average Discharge is 92%, applicable on Class A,B & C and electrically started Fire, Fire Rating 4A:144B, Can Construction : Deep drawn & CO2 Mig welded, EPDM Rubber Hose with both end Aluminum clamped, Internal Coating - Epoxy Powder coating, External Coating - Pure Polyester Powder coating (UV Resistant), Brass forged valves with safety Pin is of SS material, Made up from 2mm thick sheet, ISI Approved IS 15683:2018.

119

-

-

... More
Supplying & installing of CO2 High Pressure Portable 4.5 kg Fire Extinguisher, filled with Co2 Gas as per IS 15222, Control discharge mechanism fitted with 1 Meter Wire Braided Hose & Flat Horn with Diffuser Nozzle for dispersed discharge of CO2, Discharge Time 12 Sec, Average Discharge is 95%, Applicable on Class B, C and electrically started Fire, Fire Rating 55B, Internal coating is not applicable & External coating is of enamel spray painting, Powder Coated Handle, Valve Confirm to IS 3224 ISI Marked, CO2 Cylinder construction: hot spinning by seamless pipes & bearing ISI mark, Body confirms to IS 7285 and PESO APPROVED, Extinguishers confirmed to IS 15683:2018 and ISI marked.

6

-

-

... More
Supplying & installing of Mechanical Foam type 45 ltr. Fire Extinguisher filled with AFFF Foam (6%), Applicable fire class A&B, Controllable Discharge mechanism, Discharge Time min. 30-160 Sec, Jet Range 9 Meters, Average Discharge is 95%, Fitted with EPDM Hose with SS spring of 300mm to avoid kink (4 meter long) & Air aspirated Nozzle, CO2 gas Cartridge of 300 grams. Confirms to IS 4947, External Pure polyester (UV Resistant) and Internal Epoxy polyester powder coated, Brass forged cap, and Welding Procedure approved by TPI with 6G certification. Confroms to IS 16018:2012,Fire rating 20A:233B

1

-

-

... More
Supplying & installing of Mechanical Foam stored pressure type 9 ltr. Fire Extinguisher filled with AFFF Foam confirms to IS 4989 (Part-II). Applicable fire class A & B, UTGS Pressure Gauge, Discharge Time 35 Sec, Controllable discharge mechanism, Jet Range 7 Meters, Average Discharge is 95%, Fire Rating- 4A:144B, Can Construction : Deep drawn & CO2 Mig welded, Controllable discharge mechanism with EPDM Hose & Air aspirated Nozzle, External Pure polyester powder coated (UV resistant) and Internal Plastic lining, Brass forged valves with safety Pin is of SS material, Made up from 2 mm thick sheet, As pe IS 15683:2018 and ISI Marked.

1

-

-

... More
Supplying & installing of Automatic type 10 kg Fire Extinguishers UL listed FE-36 (HFC-236 fa) gas which is Electrically nonconductive, non corrosive, colorless and non-residual clean agent Suitable for Class A, B, C, and electrical fires approved with US EPA (Environmental Protection Agency), listing under USA Signification New Alternative Policy ( SNAP ) & also approved by UL, compliant with ASTM -D6541-11. FE-36 Fire Extinguishers having Zero Ozone Depletion Potential (ODP), low toxicity, also its replacement for Halon 1211, Halon 1201, UGTS Pressure Gauge, Made up from 2 mm thick sheet, Body Construction Deep Drawn with MIG Welding technology, External Pure polyester and Internal Epoxy polyester powder coated, Brass forged sprinkler valves, Heat Sensitive Glass bulb of 68 ° C. Area covered will be 8 m2 and volume of coverage is 10 m3. (For Server Room)

3

-

-

... More
Earthwork in excavation in foundation pipeline trenches, drain in saturated soil upto a depth of 0.6m lift upto 1.5 m including shoring strutting, pumping/ bailing out water ,stacking the excavated soil not more than 5m clear from the edge of the excavation and returning the stacked soil in 0.15 m layers when required into plinth sides of foundation, etc. consolidating each deposited layer by ramming and watering and disposing of all surplus excavated soil within a lead upto 20 m.

583.2

-

-

... More
Refilling the pipeline/foundation trenches plinth sides, foundation etc. with available excavated earth in layers not exceeding 20 cm depth consolidating each layer ramming and watering lead upto 50 M and all lifts and disposal of surplus earth as directed by Engineer in Charge.

466.56

-

-

... More
Constructing RCC pedestal for above ground piping (top above 0.45m from GL), including excavation, PCC, Concrete, shuttering, plastering above ground, steel, ISMC 150 on top of concrete pedestal, backfilling and complete as per drawing & engineer.

70

-

-

... More
Supplying, fabricating & installing of M.S. Support, for MS piping supported on Brick/ Concrete compound wall consisting with suitable size of mild steel angles, channels, flat plate, nut bolts etc..along with anchor, rod, etc. complete as per drawing & engineers instructions. The design shall consider span, weight of water filled pipe, cantilever arm etc. The structure shall be painted with 1 coat primer & 2 coats MIO & Final coat as explained elsewhere under painting.

60

-

-

... More
Providing at store or site work non-pressure RCC pipes of with collar joints conforming to IS:458-2003 revised as per amendment No.11 , including freight, carting, loading, unloading, stacking etc. complete. NP2 Class 250 mm dia

40

-

-

... More
HVAC WORKS

-

-

-

... More
Supply , Installation , testing & Commissaioning of Screw Air Cooled Chiller at ARI Condition as per specification complete with requisite accessories, independent circuits, semi-hermetic screw compressors, control panel, Flooded Sheel/Tube Evaporator, Electronic expansion valve,stepless capacity control, air cooled condenser comprising of copper tubes & aluminum fins, refrigerant piping, factory charged R 134A gas, factory wired power and control cabling, low noise fans, performance for acceptable DB level. The chiller shall be factory insulated with accoustic insulation for acceptable noise level. The Noise level shall be demonstrated during time of commissioning Shall be provided with soft starter, factory fitted/external Chiller control panel. Panel shall be microprocessor based, controls, indication, diagnostics, alarm, data recording & provision for connecting to BMS over industry recognized common platform. It is responsibility of HVAC Vendor to inculde the compatibility cards over Bacnet at Each Chiller End. Scope is inclusive of co-ordination with BMS vendor during execution for Integration of Chiller with BMS System.The chiller control cum starter panel shall be weather proof with IP66 protection, with Incoming & Outgoing Switchgear of OEM recommended sizes, inbuilt - protection against O/L, S/C, Indicating lamps, NO-NC contacts. Electrical contractor shall provide supply at the incomer of this panel. Rest Distribution is in HVAC Vendor scope. The incoming switchgear and panel casing shall be suitable to accept aluminium conductors cable which shall be provided by electrical vendor. Outgoing to chiller shall be adequate sized Copper conductor cable as per OEM Standards which shall be provided by HVAC Vendor. The chiller & chiller control panel shall be capable of load sharing, sequencing & Integration with all other Chillers Hydrophilic & Anti corrosive coating at Factory is included. Coating shall be not limited to exterior body but interior parts & piping. Chillers shall be suitable for External Environment & shall be near to sea. Accordingly necessary precautions, if required shall be taken by contractor for performance. Coating shall be Blygold Coating. Additional Coil Treatment & Coating shall be done for protection against saline & corrossive environment Installation of above Chiller on anti vibration pads on Terrace at site on civil foundation / blocks etc. Cost is incl. of Loading, Unloading, Installing on Desire location on ground floor. Associated Equipments Like Crane / Equivalent Equipment Charges.Datasheet shall be provided by Vendor. Chiller shall be energy efficient, updated to latest technology, higher efficiency, high COP Value, & optimised power consumption at full & partial loads. Certification - Eurovent/AHRI Net Chiller capacity - 300 TR Design Data - Location - Goa Ambient Condition as per ISHRAE weather data Inlet/Outlet Temperature - 12 deg.C / 6.5 deg.C Chilled Water Flowrate - 720 GPM Chiller Fouling Factor - 0.0001 hr-sq ft-deg F/BTU IKW/TR not to exceed 1.25 including condenser fans Min. COP at AHRI conditions- 3.1 Min. IPLV- 5.4 to match above efficiency criteria at least one or more compressors to have VFD/inverter. Variable Speed - With VFD Drive set , Feedback Sensor, Associated Cabling & Accessories to be incl. No. of Circuits - Atleast 3 Nos. Compressors - Atleast 1 Inverter Speed Compressor + 2 Fixed Speed Compressor

3

-

-

... More
Supply installation testing and commissioning of Chiller plant manager for the air cooled chillers operations. (To be supplied by OEM Chiller)

1

-

-

... More
Supply, Installation, testing & Commissaioning of Primary Fixed Speed Chilled Water Centrifugal Pumps sets. The pumps shall be long coupled end suction pumps. The Centrifugal pump sets will be with suitable TEFC IP 55 electric motor for circulation of Chilled water for central air-conditioning system. The pumps shall be Vertical split casing, back pull out flexible coupled End Suction Pump or Vertical split case double suction (side suction top discharge) as per the requirement. The pumps shall be provided with CI casing, SS Shaft, bronze impeller, Mechanical seals and EFF1 (IE3) Motor. All pumps shall be fixed on M.S. frame structure with base plate of pumps. The pump motor shall be suitable for 415 ± 10% volts, 50 cycles, 3 phase power supply. The pump shall be inclusive of all necessory accessories,flexible coupled, anti-vibration pads, channel base, control cabling, coupling guard, foundation bolts etc. and excluding PCC / RCC foundation. Pump, base, coupling and motor shall be factory assembled. Pumps with performance characteristics as given below, suitable for following ratings as per specifications and drawings. Pump performance characteristics shall be suitable for parallel operation in (2W + 1S) configuration.Installation of above Pumps on anti vibration pads at site on civil foundation / blocks etc. Item of Civil Foundation is incl. in HVAC vendor scope. Pump head calculation to be submitted/ crosschecked by vendor based on final pipe route as per shop drawing. Weatherproof Pump control with starter panel, Associated Cabling & Accessories to be incl.720 USGPM with 20 meter Head, Speed shall be selected as per OEM Standard for desired performance.

3

-

-

... More
Supply , Installation , testing & Commissaioning of Secondary Variable Speed Chilled Water Centrifugal Pumps sets. The pumps shall be long coupled end suction pumps. The Centrifugal pump sets will be with suitable TEFC IP 55 electric motor for circulation of Chilled water for central air-conditioning system. The pumps shall be Vertical split casing , back pull out flexible coupled End Suction Pump or Vertical split case double suction (side suction top discharge) as per the requirement.The pumps shall be provided with CI casing, SS Shaft, bronze impeller, Mechanical seals and EFF1 (IE2) Motor. All pumps shall be fixed on M.S. frame structure with base plate of pumps. The pump motor shall be suitable for 415 ± 10% volts, 50 cycles, 3 phase power supply. The pump shall be inclusive of all necessory accessories,anti-vibration pads, channel base, control cabling, coupling guard, foundation bolts etc. and excluding PCC / RCC foundation. Pump, base, coupling and motor shall be factory assembled. Pumps with performance characteristics as given below, suitable for following ratings as per specifications and drawings. Pump performance characteristics shall be suitable for parallel operation in (4W +1 S) configuration.Installation of above Pumps on anti vibration pads at site on civil foundation / blocks etc. Item of Civil Foundation is incl. in HVAC vendor scope. Pump head calculation to be submitted/ crosschecked by vendor based on final pipe route as per shop drawing. Weatherproof Pump control with starter panel & VFD Drive set, Feedback Sensor, Associated Cabling & Accessories to be incl.660 USGPM with with 35 meter Head, Speed shall be selected as per OEM Standard for desired performance.

3

-

-

... More
Supply, Installation , Testing & Commissaioning of PVC make up tank complete with high & low indicator, BMS Compatible sensor, control wiring, piping connections float valves,drain valves,over flow connection and Digital Water Meter required for munciple supply. The Make up water tank should be provided with two outlet connection for chilled water circuit. Capacity 3000 Liters. Tank to be mounted above the Pressurisation pump on a common framework. Framework in HVAC Vendor scope & incl. in this line item. Make Tank shall be complete with Solenoid Valves etc.

1

-

-

... More
Supply, Installation, testing & Commissaioning of Automatic Pressurization unit consisting of Microprocessor based control panel with dry run protection, duty cycling, Double pumps in (1W + 1S) configuration suitable for above mentioned system. The unit shall be capable of pumping water & shall include atleast W+S Pump.The unit shall be designed to operate automatically & maintain pressure in the chilled water line. The pressure can be set on the pressure switch & accordingly pump should start & stop on the basis of the line pressure. The control panel should be capable of running the pumps alternatively ensuring both pumps are in use at equal time intervals. The unit shall be complete with relief valve, pressure guage control panel, pressure switch drain,pipes fittings valves etc. Pump should be sized to create required pressure in the system and complete with check valve, Y strainer, butterfly valves, flexible connections rubber pads, flow meter etc. Control Panel shall be in weatherproof enclosure & compatible with BMS System.

1

-

-

... More
Supply, installation , Testing and Commissioning of Closed Type Expansion tanks of 2000 Ltrs capacity with complete skid and pressurisation module.

1

-

-

... More
Supply, Installation, Testing & Commissioning of Air separator of following flow rate and connection size: including 32 mm nitrile rubber insulation.490.5 m3/hr and connection size: 300mm

1

-

-

... More
Supply Installation & Errection of Flow Meter Electromagnetic type of approved Make & suitable for 163.5m^3/hr. flow rate Including fabrication of reducers or flanges as applicable on both sides of flow Meter.

3

-

-

... More
Providing and fixing of Cushy foot / spring mounts for Chiller's and Pump's as per requirement.

1

-

-

... More
Supply, Installation , Testing & Commissaioning of following nominal sizes of Chilled water piping inside the building (with necessary clamps, vibration isolators and fittings but excluding valves, strainers, gauges etc). duly insulated with following closed cell elastometric Nitrile Rubber of minimum 45 kg/cu.m Density, tharmal conductivity 0.037 W/MK or better at 20 deg mean temprature class 'O' insulation applied by suitable adhesive complete including repairing of damage to building etc. as per specification and as required complete in all respect. Note:- The Pipe of size 150 mm & below shall be M.S 'C' class as per IS ; 1239 and Pipe size above 150 mm shall be welded black steel pipe heavy class as per IS ; 3589 from minimum 6.35mm thick MS sheet for Pipes upto 350 mm dia. and from minimum 7mm thick MS sheet for pipes of 400 mm dia and above. 200 mm Ø Piping with 50mm thick insulation

210

-

-

... More
Supply, Installation , Testing & Commissaioning of following nominal sizes of Chilled water piping inside the building (with necessary clamps, vibration isolators and fittings but excluding valves, strainers, gauges etc). duly insulated with following closed cell elastometric Nitrile Rubber of minimum 45 kg/cu.m Density, tharmal conductivity 0.037 W/MK or better at 20 deg mean temprature class 'O' insulation applied by suitable adhesive complete including repairing of damage to building etc. as per specification and as required complete in all respect. Note:- The Pipe of size 150 mm & below shall be M.S 'C' class as per IS ; 1239 and Pipe size above 150 mm shall be welded black steel pipe heavy class as per IS ; 3589 from minimum 6.35mm thick MS sheet for Pipes upto 350 mm dia. and from minimum 7mm thick MS sheet for pipes of 400 mm dia and above. 150 mm Ø Piping with 50mm thick insulation

280

-

-

... More
Supply, Installation , Testing & Commissaioning of following nominal sizes of Chilled water piping inside the building (with necessary clamps, vibration isolators and fittings but excluding valves, strainers, gauges etc). duly insulated with following closed cell elastometric Nitrile Rubber of minimum 45 kg/cu.m Density, tharmal conductivity 0.037 W/MK or better at 20 deg mean temprature class 'O' insulation applied by suitable adhesive complete including repairing of damage to building etc. as per specification and as required complete in all respect. Note:- The Pipe of size 150 mm & below shall be M.S 'C' class as per IS ; 1239 and Pipe size above 150 mm shall be welded black steel pipe heavy class as per IS ; 3589 from minimum 6.35mm thick MS sheet for Pipes upto 350 mm dia. and from minimum 7mm thick MS sheet for pipes of 400 mm dia and above. 100 mm Ø Piping with 32mm thick insulation

680

-

-

... More
Supply, Installation , Testing & Commissaioning of following nominal sizes of Chilled water piping inside the building (with necessary clamps, vibration isolators and fittings but excluding valves, strainers, gauges etc). duly insulated with following closed cell elastometric Nitrile Rubber of minimum 45 kg/cu.m Density, tharmal conductivity 0.037 W/MK or better at 20 deg mean temprature class 'O' insulation applied by suitable adhesive complete including repairing of damage to building etc. as per specification and as required complete in all respect. Note:- The Pipe of size 150 mm & below shall be M.S 'C' class as per IS ; 1239 and Pipe size above 150 mm shall be welded black steel pipe heavy class as per IS ; 3589 from minimum 6.35mm thick MS sheet for Pipes upto 350 mm dia. and from minimum 7mm thick MS sheet for pipes of 400 mm dia and above. 80 mm Ø Piping with 32mm thick insulation

210

-

-

... More
Supply, Installation , Testing & Commissaioning of following nominal sizes of Chilled water piping inside the building (with necessary clamps, vibration isolators and fittings but excluding valves, strainers, gauges etc). duly insulated with following closed cell elastometric Nitrile Rubber of minimum 45 kg/cu.m Density, tharmal conductivity 0.037 W/MK or better at 20 deg mean temprature class 'O' insulation applied by suitable adhesive complete including repairing of damage to building etc. as per specification and as required complete in all respect. Note:- The Pipe of size 150 mm & below shall be M.S 'C' class as per IS ; 1239 and Pipe size above 150 mm shall be welded black steel pipe heavy class as per IS ; 3589 from minimum 6.35mm thick MS sheet for Pipes upto 350 mm dia. and from minimum 7mm thick MS sheet for pipes of 400 mm dia and above. 65 mm Ø Piping with 19mm thick insulation

600

-

-

... More
Supply, Installation , Testing & Commissaioning of following nominal sizes of Chilled water piping inside the building (with necessary clamps, vibration isolators and fittings but excluding valves, strainers, gauges etc). duly insulated with following closed cell elastometric Nitrile Rubber of minimum 45 kg/cu.m Density, tharmal conductivity 0.037 W/MK or better at 20 deg mean temprature class 'O' insulation applied by suitable adhesive complete including repairing of damage to building etc. as per specification and as required complete in all respect. Note:- The Pipe of size 150 mm & below shall be M.S 'C' class as per IS ; 1239 and Pipe size above 150 mm shall be welded black steel pipe heavy class as per IS ; 3589 from minimum 6.35mm thick MS sheet for Pipes upto 350 mm dia. and from minimum 7mm thick MS sheet for pipes of 400 mm dia and above.50 mm Ø Piping with 19mm thick insulation

470

-

-

... More
Supply, Installation , Testing & Commissaioning of following nominal sizes of Chilled water piping inside the building (with necessary clamps, vibration isolators and fittings but excluding valves, strainers, gauges etc). duly insulated with following closed cell elastometric Nitrile Rubber of minimum 45 kg/cu.m Density, tharmal conductivity 0.037 W/MK or better at 20 deg mean temprature class 'O' insulation applied by suitable adhesive complete including repairing of damage to building etc. as per specification and as required complete in all respect. Note:- The Pipe of size 150 mm & below shall be M.S 'C' class as per IS ; 1239 and Pipe size above 150 mm shall be welded black steel pipe heavy class as per IS ; 3589 from minimum 6.35mm thick MS sheet for Pipes upto 350 mm dia. and from minimum 7mm thick MS sheet for pipes of 400 mm dia and above. 40 mm Ø Piping with 19mm thick insulation

80

-

-

... More
Supply, Installation , Testing & Commissaioning of following nominal sizes of Chilled water piping inside the building (with necessary clamps, vibration isolators and fittings but excluding valves, strainers, gauges etc). duly insulated with following closed cell elastometric Nitrile Rubber of minimum 45 kg/cu.m Density, tharmal conductivity 0.037 W/MK or better at 20 deg mean temprature class 'O' insulation applied by suitable adhesive complete including repairing of damage to building etc. as per specification and as required complete in all respect. Note:- The Pipe of size 150 mm & below shall be M.S 'C' class as per IS ; 1239 and Pipe size above 150 mm shall be welded black steel pipe heavy class as per IS ; 3589 from minimum 6.35mm thick MS sheet for Pipes upto 350 mm dia. and from minimum 7mm thick MS sheet for pipes of 400 mm dia and above. 32 mm Ø Piping with 19mm thick insulation

420

-

-

... More
Supply, Installation , Testing & Commissaioning of following nominal sizes of Chilled water piping inside the building (with necessary clamps, vibration isolators and fittings but excluding valves, strainers, gauges etc). duly insulated with following closed cell elastometric Nitrile Rubber of minimum 45 kg/cu.m Density, tharmal conductivity 0.037 W/MK or better at 20 deg mean temprature class 'O' insulation applied by suitable adhesive complete including repairing of damage to building etc. as per specification and as required complete in all respect. Note:- The Pipe of size 150 mm & below shall be M.S 'C' class as per IS ; 1239 and Pipe size above 150 mm shall be welded black steel pipe heavy class as per IS ; 3589 from minimum 6.35mm thick MS sheet for Pipes upto 350 mm dia. and from minimum 7mm thick MS sheet for pipes of 400 mm dia and above. 25 mm Ø Piping with 19mm thick insulation

480

-

-

... More
Supply, Installation, testing & Commissioning of Butterfly Valve with C I body SS disc, nitril rubber seal & O ring PN-16 rating with Extended spindle to take care the Insulation Thickness as per Following Sizes.All Valves will be Insulated using Nitrile Rubber insulation Material and Thickness will be appx. 32mm for Chilled water service. 150 mm Ø

21

-

-

... More
Supply, Installation, testing & Commissioning of Butterfly Valve with C I body SS disc, nitril rubber seal & O ring PN-16 rating with Extended spindle to take care the Insulation Thickness as per Following Sizes.All Valves will be Insulated using Nitrile Rubber insulation Material and Thickness will be appx. 32mm for Chilled water service. 100 mm Ø

2

-

-

... More
Supply, Installation, testing & Commissioning of Butterfly Valve with C I body SS disc, nitril rubber seal & O ring PN-16 rating with Extended spindle to take care the Insulation Thickness as per Following Sizes.All Valves will be Insulated using Nitrile Rubber insulation Material and Thickness will be appx. 32mm for Chilled water service. 80 mm Ø

2

-

-

... More
Supply, Installation, testing & Commissioning of Butterfly Valve with C I body SS disc, nitril rubber seal & O ring PN-16 rating with Extended spindle to take care the Insulation Thickness as per Following Sizes.All Valves will be Insulated using Nitrile Rubber insulation Material and Thickness will be appx. 32mm for Chilled water service. 65 mm Ø

2

-

-

... More
Supply, Installation, testing & Commissioning of Butterfly Valve with C I body SS disc, nitril rubber seal & O ring PN-16 rating with Extended spindle to take care the Insulation Thickness as per Following Sizes.All Valves will be Insulated using Nitrile Rubber insulation Material and Thickness will be appx. 32mm for Chilled water service. 50 mm Ø

2

-

-

... More
0Supply, Installation, testing & Commissioning of 150 mm Ø C.S. Balancing Valve of Advance make or equivalent with Extended spindle to take care the Insulation Thickness as per Following Sizes, .All Valves will be Insulated using Nitrile Rubber insulation Material with fiber cloth and Thickness will be appx. 32mm for 7 Deg C & 50 deg C Service with all joining tape and accessories. Supply should include the required tubing and isolation valves so that the differential pressure may be measured across the Valve.

3

-

-

... More
0Supply, Installation, testing & Commissioning of 100 mm Ø C.S. Balancing Valve of Advance make or equivalent with Extended spindle to take care the Insulation Thickness as per Following Sizes, .All Valves will be Insulated using Nitrile Rubber insulation Material with fiber cloth and Thickness will be appx. 32mm for 7 Deg C & 50 deg C Service with all joining tape and accessories. Supply should include the required tubing and isolation valves so that the differential pressure may be measured across the Valve.

2

-

-

... More
0Supply, Installation, testing & Commissioning of 80 mm Ø C.S. Balancing Valve of Advance make or equivalent with Extended spindle to take care the Insulation Thickness as per Following Sizes, .All Valves will be Insulated using Nitrile Rubber insulation Material with fiber cloth and Thickness will be appx. 32mm for 7 Deg C & 50 deg C Service with all joining tape and accessories. Supply should include the required tubing and isolation valves so that the differential pressure may be measured across the Valve.

2

-

-

... More
0Supply, Installation, testing & Commissioning of 65 mm Ø C.S. Balancing Valve of Advance make or equivalent with Extended spindle to take care the Insulation Thickness as per Following Sizes, .All Valves will be Insulated using Nitrile Rubber insulation Material with fiber cloth and Thickness will be appx. 32mm for 7 Deg C & 50 deg C Service with all joining tape and accessories. Supply should include the required tubing and isolation valves so that the differential pressure may be measured across the Valve.

2

-

-

... More
0Supply, Installation, testing & Commissioning of 50 mm Ø C.S. Balancing Valve of Advance make or equivalent with Extended spindle to take care the Insulation Thickness as per Following Sizes, .All Valves will be Insulated using Nitrile Rubber insulation Material with fiber cloth and Thickness will be appx. 32mm for 7 Deg C & 50 deg C Service with all joining tape and accessories. Supply should include the required tubing and isolation valves so that the differential pressure may be measured across the Valve.

2

-

-

... More
Supply, Installation, testing & Commissioning of 150 mm Ø C.S. NRV as per Following Sizes,All will be Insulated Nitrile Rubber insulation Material with fiber and Thickness will be appx. 32mm for 5 Deg C & 50 deg C Service with all joining tape and accessories .

6

-

-

... More
0Supply, Installation, testing & Commissioning of PRESSURE INDEPENDENT CONTROL VALVE (PICV) as per Following Sizes,All will be Insulated Nitrile Rubber insulation Material with fiber and Thickness will be appx. 32mm for 5 Deg C & 50 deg C Service with all joining tape and accessories. (including provisions for BMS/IoT Compatibility) 200 mm Ø

2

-

-

... More
0Supply, Installation, testing & Commissioning of PRESSURE INDEPENDENT CONTROL VALVE (PICV) as per Following Sizes,All will be Insulated Nitrile Rubber insulation Material with fiber and Thickness will be appx. 32mm for 5 Deg C & 50 deg C Service with all joining tape and accessories. (including provisions for BMS/IoT Compatibility) 150 mm Ø

6

-

-

... More
Y - STRAINERS of Ductile CI body flanged ends with stainless steel strainer for chilled water circulation, All will be Insulated Nitrile Rubber insulation Material with fiber and Thickness will be appx. 32mm for 5 Deg C & 50 deg C Service with all joining tape and accessories .150 mm Ø

9

-

-

... More
Supply, Installation, testing & Commissioning of Differential Pressure transmitter of water to control the flow. Integrated with pump controller.

3

-

-

... More
Supply, Installation, testing & Commissioning of Modulating type Motorized butterfly valve with actuator. (including provisions for BMS/IoT Compatibility) 150 mm Ø

9

-

-

... More
Supply, Installation of industrial Dial Type Pressure Gauge with Aluminum Die cast body and all internal working parts are of SS 304 construction and along with SS syphon of approved Make & Range 0-10 Kg/cm2 Connection Size 25NB Dial Size 150/100mm with SS investment casting ball valve.

18

-

-

... More
Supply, Installation of industrial Dial Type Temperature Gauge with Aluminum Die cast body and all internal working parts are of SS 304 construction and along with thermowell of approved Make. Connection Size 15NB Dial Size 150/100mm with SS investment casting ball valve.

9

-

-

... More
Providing and fixing of ball/drain valve of approved quality.25mm nominal outer dia

10

-

-

... More
Supply, Installation of Rubber Bellow of Size along with Flanges Suitable for 150# Rating of the following sizes along with external guide frame etc For Pump Suction and Discharge Lines size-150NB

18

-

-

... More
Supply, Installation, Testing & Commissioning of Chilled Water Line Flow Switch at Chiller side. (including provisions for BMS/IoT Compatibility)

3

-

-

... More
Supply, Installation, testing & Commissioning of Auto Air Vent Size- 25MM NB.

3

-

-

... More
Supply, Installation , testing & Commissioning of AHU - 6400 CFM, 16.0 TR, 20 mm Static, Ceiling Suspended, Side Discharge, Chilled Water Horizontal/Vertical, Top/Side Discharge, Floor mounted/Ceiling Suspended Air Handling Unit of mentioned capacity. Double skin with blower fan,cooling coil, SS condensate pan and air filters. Housing / Casing to be of Double Skin 43 mm thick, CFC Free PUF injected (Density: 40 kg / Cu. m.) using aluminium extrusion, Thermal break Al profile with thermal barrier The panels shall be made of 1.2 mm galvanized pre coated sheet on out side and 0.8 mm galvanized sheet inside CFC Free Poly Utherane Foam between two metal panels for addittional rigidityCooling coil section with aluminium finned copper tubes (tubes thickness not less than 0.5mm) cooling coil of min 6 row deep. Di-electric union to be used in case of dissimilar metal connection.Multiple Fans as per Air flow requirementFan static calculation to be provided by the Vender before ordering AHU.IEE2 Motor For energy efficiencyMotors to be standard 3 phase 415 V 50 Hz, IP 55Multi row cooling coils having anti-corrossive hydrophilic coating Aluminium finsCoil Face velocity to be 500 fpm. Coil frame shall be SS 304Efficient Air Filters (50 MM thick) equivalent to EU-4 of EN-779 & MERV 8 prefilter specifications. Filter efficiency shall be 90% down to 3.0-10 micron Performance as per ASHRAE 52.1 Easily Cleanable & washableInspection Door with Safety Feature & Limit Switch Weather proof lights inside fan section Fan motor based shall be properly earthed For floor mounted units the base shall be of heavy duty G.I duly powder coated. Flexible Connections between fan outlet & supply air duct as per site requirement Installation of Floor Mounted AHU on anti vibration pads in AHU room at site on civil foundation / blocks, AHU Panel, Cabling, accessories, etc. Item of Civil Foundation is covered under separate item .Installation of Ceiling Suspended AHU on ceiling suspension at site, AHU Panel, Cabling, accessories, etc. For Installation of ceiling suspended units HVAC Contractor to submit for approval GA of typical mounting of ceiling suspended units. Contractor/OEM to ensure the total load is distributed from point load to distributed load suitable for ceiling load available. Job includes providing ceiling suspended AHU supports / hangers installation. Fully threaded GI bolts will be installed on anchor Fasteners. MS angle plates of requisite size as applicable will be mounted to these hangers by check nuts and spring washers, on which AHU will be provided. Flexible fire retardant double canvass connections, volume control damper Connections designed so as to prevent fan vibration being transmitted to ductwork with noise in conditioned spacePrice should be included of Supply and Installation of Valve Assembly for AHU with microprocessor based control, built in PICV, valve controllers, Thermostats, Butterfly Valves, strainers, drain pumps.Including Return Air sensor with corded remote and its control wiring.Noise Level as per statutory requirements within limits prescribed (upto 55 dB at 3 m distance)AHU Complete with AHU Electric Panel AHU Electric Panel to have electric power provision with incomer & outgoing section Electrical Contractor will provide power to AHU Panel at Incomer Sid e Rest electrical distribution is in HVAC Vendor Scope Provision of spare to be kept in AHU Panel Earthing till AHU Room will be provided by Electrical Contractor Rest earthing distribution is in HVAC Vendor Scope AHU Panel to have Emergency Auxillary Contacts for operation mentioned below AHU Panel to have Emergency Auxillary Contacts for operation mentioned below In case of fire, fire alarm panel will give "1 No." of DC signal to AHU Panel through "Control Module" On receipt of signal from Fire Alarm Panel the AHU Panel trip the AHU The Power Cabling & design between AHU Panel Contacts to Trip AHU is incl. in HVAC Vendor scope Power cabling shall be 4C, copper conductor, armoured cable from Starter Panel to AHU motor with single compression gland. Control cabling, as applicable shall be copper conductor, armoured cable for 2 way valve operation between sensor, actuator etc. Cabling to run within suitable sized cable tray / trunking Necessary temperature sensor to be incl. in cost with associated wiring. AHU Panel to have potential free contacts for taking AHU Incomer Trip Status and on/Off Command on BMS AHU Panel to have potential free contacts for taking AHU Incomer Trip Status and on/Off Command on BMS Including DP Sensor's for filter status and Blower Status.Supply, drain connections, with Drain Pump only for Ceiling suspended. stainless steel (18G) drain pan insulated sandwitch with PUF insulation, auto purge/Ball valve wherever requiredNote:- Civil Foundations for Installation of AHU and AHU Panel (In case AHU Panel is floor mounted) AHU and AHU Panel to be installed on separate civil foundation Item to be quoted as lot. for all AHU Rooms (if required)

14

-

-

... More
Supply, Installation , testing & Commissioning of AHU - 3600 CFM, 9.0 TR, 20 mm Static, Ceiling Suspended, Side Discharge,Chilled Water Horizontal/Vertical, Top/Side Discharge, Floor mounted/Ceiling Suspended Air Handling Unit of mentioned capacity. Double skin with blower fan,cooling coil, SS condensate pan and air filters. Housing / Casing to be of Double Skin 43 mm thick, CFC Free PUF injected (Density: 40 kg / Cu. m.) using aluminium extrusion, Thermal break Al profile with thermal barrier The panels shall be made of 1.2 mm galvanized pre coated sheet on out side and 0.8 mm galvanized sheet inside CFC Free Poly Utherane Foam between two metal panels for addittional rigidityCooling coil section with aluminium finned copper tubes (tubes thickness not less than 0.5mm) cooling coil of min 6 row deep. Di-electric union to be used in case of dissimilar metal connection.Multiple Fans as per Air flow requirementFan static calculation to be provided by the Vender before ordering AHU.IEE2 Motor For energy efficiencyMotors to be standard 3 phase 415 V 50 Hz, IP 55Multi row cooling coils having anti-corrossive hydrophilic coating Aluminium finsCoil Face velocity to be 500 fpm. Coil frame shall be SS 304Efficient Air Filters (50 MM thick) equivalent to EU-4 of EN-779 & MERV 8 prefilter specifications. Filter efficiency shall be 90% down to 3.0-10 micron Performance as per ASHRAE 52.1 Easily Cleanable & washableInspection Door with Safety Feature & Limit Switch Weather proof lights inside fan section Fan motor based shall be properly earthed For floor mounted units the base shall be of heavy duty G.I duly powder coated. Flexible Connections between fan outlet & supply air duct as per site requirement Installation of Floor Mounted AHU on anti vibration pads in AHU room at site on civil foundation / blocks, AHU Panel, Cabling, accessories, etc. Item of Civil Foundation is covered under separate item .Installation of Ceiling Suspended AHU on ceiling suspension at site, AHU Panel, Cabling, accessories, etc. For Installation of ceiling suspended units HVAC Contractor to submit for approval GA of typical mounting of ceiling suspended units. Contractor/OEM to ensure the total load is distributed from point load to distributed load suitable for ceiling load available. Job includes providing ceiling suspended AHU supports / hangers installation. Fully threaded GI bolts will be installed on anchor Fasteners. MS angle plates of requisite size as applicable will be mounted to these hangers by check nuts and spring washers, on which AHU will be provided. Flexible fire retardant double canvass connections, volume control damper Connections designed so as to prevent fan vibration being transmitted to ductwork with noise in conditioned spacePrice should be included of Supply and Installation of Valve Assembly for AHU with microprocessor based control, built in PICV, valve controllers, Thermostats, Butterfly Valves, strainers, drain pumps.Including Return Air sensor with corded remote and its control wiring.Noise Level as per statutory requirements within limits prescribed (upto 55 dB at 3 m distance)AHU Complete with AHU Electric Panel AHU Electric Panel to have electric power provision with incomer & outgoing section Electrical Contractor will provide power to AHU Panel at Incomer Sid e Rest electrical distribution is in HVAC Vendor Scope Provision of spare to be kept in AHU Panel Earthing till AHU Room will be provided by Electrical Contractor Rest earthing distribution is in HVAC Vendor Scope AHU Panel to have Emergency Auxillary Contacts for operation mentioned below AHU Panel to have Emergency Auxillary Contacts for operation mentioned below In case of fire, fire alarm panel will give "1 No." of DC signal to AHU Panel through "Control Module" On receipt of signal from Fire Alarm Panel the AHU Panel trip the AHU The Power Cabling & design between AHU Panel Contacts to Trip AHU is incl. in HVAC Vendor scope Power cabling shall be 4C, copper conductor, armoured cable from Starter Panel to AHU motor with single compression gland. Control cabling, as applicable shall be copper conductor, armoured cable for 2 way valve operation between sensor, actuator etc. Cabling to run within suitable sized cable tray / trunking Necessary temperature sensor to be incl. in cost with associated wiring. AHU Panel to have potential free contacts for taking AHU Incomer Trip Status and on/Off Command on BMS AHU Panel to have potential free contacts for taking AHU Incomer Trip Status and on/Off Command on BMS Including DP Sensor's for filter status and Blower Status.Supply, drain connections, with Drain Pump only for Ceiling suspended. stainless steel (18G) drain pan insulated sandwitch with PUF insulation, auto purge/Ball valve wherever requiredNote:- Civil Foundations for Installation of AHU and AHU Panel (In case AHU Panel is floor mounted) AHU and AHU Panel to be installed on separate civil foundation Item to be quoted as lot. for all AHU Rooms (if required)

8

-

-

... More
Supply, Installation , testing & Commissioning of AHU - AHU - 3200 CFM, 8.0 TR, 20 mm Static, Ceiling Suspended, Side Discharge,,Chilled Water Horizontal/Vertical, Top/Side Discharge, Floor mounted/Ceiling Suspended Air Handling Unit of mentioned capacity. Double skin with blower fan,cooling coil, SS condensate pan and air filters. Housing / Casing to be of Double Skin 43 mm thick, CFC Free PUF injected (Density: 40 kg / Cu. m.) using aluminium extrusion, Thermal break Al profile with thermal barrier The panels shall be made of 1.2 mm galvanized pre coated sheet on out side and 0.8 mm galvanized sheet inside CFC Free Poly Utherane Foam between two metal panels for addittional rigidityCooling coil section with aluminium finned copper tubes (tubes thickness not less than 0.5mm) cooling coil of min 6 row deep. Di-electric union to be used in case of dissimilar metal connection.Multiple Fans as per Air flow requirementFan static calculation to be provided by the Vender before ordering AHU.IEE2 Motor For energy efficiencyMotors to be standard 3 phase 415 V 50 Hz, IP 55Multi row cooling coils having anti-corrossive hydrophilic coating Aluminium finsCoil Face velocity to be 500 fpm. Coil frame shall be SS 304Efficient Air Filters (50 MM thick) equivalent to EU-4 of EN-779 & MERV 8 prefilter specifications. Filter efficiency shall be 90% down to 3.0-10 micron Performance as per ASHRAE 52.1 Easily Cleanable & washableInspection Door with Safety Feature & Limit Switch Weather proof lights inside fan section Fan motor based shall be properly earthed For floor mounted units the base shall be of heavy duty G.I duly powder coated. Flexible Connections between fan outlet & supply air duct as per site requirement Installation of Floor Mounted AHU on anti vibration pads in AHU room at site on civil foundation / blocks, AHU Panel, Cabling, accessories, etc. Item of Civil Foundation is covered under separate item .Installation of Ceiling Suspended AHU on ceiling suspension at site, AHU Panel, Cabling, accessories, etc. For Installation of ceiling suspended units HVAC Contractor to submit for approval GA of typical mounting of ceiling suspended units. Contractor/OEM to ensure the total load is distributed from point load to distributed load suitable for ceiling load available. Job includes providing ceiling suspended AHU supports / hangers installation. Fully threaded GI bolts will be installed on anchor Fasteners. MS angle plates of requisite size as applicable will be mounted to these hangers by check nuts and spring washers, on which AHU will be provided. Flexible fire retardant double canvass connections, volume control damper Connections designed so as to prevent fan vibration being transmitted to ductwork with noise in conditioned spacePrice should be included of Supply and Installation of Valve Assembly for AHU with microprocessor based control, built in PICV, valve controllers, Thermostats, Butterfly Valves, strainers, drain pumps.Including Return Air sensor with corded remote and its control wiring.Noise Level as per statutory requirements within limits prescribed (upto 55 dB at 3 m distance)AHU Complete with AHU Electric Panel AHU Electric Panel to have electric power provision with incomer & outgoing section Electrical Contractor will provide power to AHU Panel at Incomer Sid e Rest electrical distribution is in HVAC Vendor Scope Provision of spare to be kept in AHU Panel Earthing till AHU Room will be provided by Electrical Contractor Rest earthing distribution is in HVAC Vendor Scope AHU Panel to have Emergency Auxillary Contacts for operation mentioned below AHU Panel to have Emergency Auxillary Contacts for operation mentioned below In case of fire, fire alarm panel will give "1 No." of DC signal to AHU Panel through "Control Module" On receipt of signal from Fire Alarm Panel the AHU Panel trip the AHU The Power Cabling & design between AHU Panel Contacts to Trip AHU is incl. in HVAC Vendor scope Power cabling shall be 4C, copper conductor, armoured cable from Starter Panel to AHU motor with single compression gland. Control cabling, as applicable shall be copper conductor, armoured cable for 2 way valve operation between sensor, actuator etc. Cabling to run within suitable sized cable tray / trunking Necessary temperature sensor to be incl. in cost with associated wiring. AHU Panel to have potential free contacts for taking AHU Incomer Trip Status and on/Off Command on BMS AHU Panel to have potential free contacts for taking AHU Incomer Trip Status and on/Off Command on BMS Including DP Sensor's for filter status and Blower Status.Supply, drain connections, with Drain Pump only for Ceiling suspended. stainless steel (18G) drain pan insulated sandwitch with PUF insulation, auto purge/Ball valve wherever requiredNote:- Civil Foundations for Installation of AHU and AHU Panel (In case AHU Panel is floor mounted) AHU and AHU Panel to be installed on separate civil foundation Item to be quoted as lot. for all AHU Rooms (if required)

7

-

-

... More
Supply, Installation , testing & Commissioning of AAHU - 2400 CFM, 6.0 TR, 15 mm Static, Ceiling Suspended, Side Discharge,,,Chilled Water Horizontal/Vertical, Top/Side Discharge, Floor mounted/Ceiling Suspended Air Handling Unit of mentioned capacity. Double skin with blower fan,cooling coil, SS condensate pan and air filters. Housing / Casing to be of Double Skin 43 mm thick, CFC Free PUF injected (Density: 40 kg / Cu. m.) using aluminium extrusion, Thermal break Al profile with thermal barrier The panels shall be made of 1.2 mm galvanized pre coated sheet on out side and 0.8 mm galvanized sheet inside CFC Free Poly Utherane Foam between two metal panels for addittional rigidityCooling coil section with aluminium finned copper tubes (tubes thickness not less than 0.5mm) cooling coil of min 6 row deep. Di-electric union to be used in case of dissimilar metal connection.Multiple Fans as per Air flow requirementFan static calculation to be provided by the Vender before ordering AHU.IEE2 Motor For energy efficiencyMotors to be standard 3 phase 415 V 50 Hz, IP 55Multi row cooling coils having anti-corrossive hydrophilic coating Aluminium finsCoil Face velocity to be 500 fpm. Coil frame shall be SS 304Efficient Air Filters (50 MM thick) equivalent to EU-4 of EN-779 & MERV 8 prefilter specifications. Filter efficiency shall be 90% down to 3.0-10 micron Performance as per ASHRAE 52.1 Easily Cleanable & washableInspection Door with Safety Feature & Limit Switch Weather proof lights inside fan section Fan motor based shall be properly earthed For floor mounted units the base shall be of heavy duty G.I duly powder coated. Flexible Connections between fan outlet & supply air duct as per site requirement Installation of Floor Mounted AHU on anti vibration pads in AHU room at site on civil foundation / blocks, AHU Panel, Cabling, accessories, etc. Item of Civil Foundation is covered under separate item .Installation of Ceiling Suspended AHU on ceiling suspension at site, AHU Panel, Cabling, accessories, etc. For Installation of ceiling suspended units HVAC Contractor to submit for approval GA of typical mounting of ceiling suspended units. Contractor/OEM to ensure the total load is distributed from point load to distributed load suitable for ceiling load available. Job includes providing ceiling suspended AHU supports / hangers installation. Fully threaded GI bolts will be installed on anchor Fasteners. MS angle plates of requisite size as applicable will be mounted to these hangers by check nuts and spring washers, on which AHU will be provided. Flexible fire retardant double canvass connections, volume control damper Connections designed so as to prevent fan vibration being transmitted to ductwork with noise in conditioned spacePrice should be included of Supply and Installation of Valve Assembly for AHU with microprocessor based control, built in PICV, valve controllers, Thermostats, Butterfly Valves, strainers, drain pumps.Including Return Air sensor with corded remote and its control wiring.Noise Level as per statutory requirements within limits prescribed (upto 55 dB at 3 m distance)AHU Complete with AHU Electric Panel AHU Electric Panel to have electric power provision with incomer & outgoing section Electrical Contractor will provide power to AHU Panel at Incomer Sid e Rest electrical distribution is in HVAC Vendor Scope Provision of spare to be kept in AHU Panel Earthing till AHU Room will be provided by Electrical Contractor Rest earthing distribution is in HVAC Vendor Scope AHU Panel to have Emergency Auxillary Contacts for operation mentioned below AHU Panel to have Emergency Auxillary Contacts for operation mentioned below In case of fire, fire alarm panel will give "1 No." of DC signal to AHU Panel through "Control Module" On receipt of signal from Fire Alarm Panel the AHU Panel trip the AHU The Power Cabling & design between AHU Panel Contacts to Trip AHU is incl. in HVAC Vendor scope Power cabling shall be 4C, copper conductor, armoured cable from Starter Panel to AHU motor with single compression gland. Control cabling, as applicable shall be copper conductor, armoured cable for 2 way valve operation between sensor, actuator etc. Cabling to run within suitable sized cable tray / trunking Necessary temperature sensor to be incl. in cost with associated wiring. AHU Panel to have potential free contacts for taking AHU Incomer Trip Status and on/Off Command on BMS AHU Panel to have potential free contacts for taking AHU Incomer Trip Status and on/Off Command on BMS Including DP Sensor's for filter status and Blower Status.Supply, drain connections, with Drain Pump only for Ceiling suspended. stainless steel (18G) drain pan insulated sandwitch with PUF insulation, auto purge/Ball valve wherever requiredNote:- Civil Foundations for Installation of AHU and AHU Panel (In case AHU Panel is floor mounted) AHU and AHU Panel to be installed on separate civil foundation Item to be quoted as lot. for all AHU Rooms (if required)

14

-

-

... More
Supply, Installation , testing & Commissioning of AHU - 2000 CFM, 5.0 TR, 15 mm Static, Ceiling Suspended, Side Discharge,,Chilled Water Horizontal/Vertical, Top/Side Discharge, Floor mounted/Ceiling Suspended Air Handling Unit of mentioned capacity. Double skin with blower fan,cooling coil, SS condensate pan and air filters. Housing / Casing to be of Double Skin 43 mm thick, CFC Free PUF injected (Density: 40 kg / Cu. m.) using aluminium extrusion, Thermal break Al profile with thermal barrier The panels shall be made of 1.2 mm galvanized pre coated sheet on out side and 0.8 mm galvanized sheet inside CFC Free Poly Utherane Foam between two metal panels for addittional rigidityCooling coil section with aluminium finned copper tubes (tubes thickness not less than 0.5mm) cooling coil of min 6 row deep. Di-electric union to be used in case of dissimilar metal connection.Multiple Fans as per Air flow requirementFan static calculation to be provided by the Vender before ordering AHU.IEE2 Motor For energy efficiencyMotors to be standard 3 phase 415 V 50 Hz, IP 55Multi row cooling coils having anti-corrossive hydrophilic coating Aluminium finsCoil Face velocity to be 500 fpm. Coil frame shall be SS 304Efficient Air Filters (50 MM thick) equivalent to EU-4 of EN-779 & MERV 8 prefilter specifications. Filter efficiency shall be 90% down to 3.0-10 micron Performance as per ASHRAE 52.1 Easily Cleanable & washableInspection Door with Safety Feature & Limit Switch Weather proof lights inside fan section Fan motor based shall be properly earthed For floor mounted units the base shall be of heavy duty G.I duly powder coated. Flexible Connections between fan outlet & supply air duct as per site requirement Installation of Floor Mounted AHU on anti vibration pads in AHU room at site on civil foundation / blocks, AHU Panel, Cabling, accessories, etc. Item of Civil Foundation is covered under separate item .Installation of Ceiling Suspended AHU on ceiling suspension at site, AHU Panel, Cabling, accessories, etc. For Installation of ceiling suspended units HVAC Contractor to submit for approval GA of typical mounting of ceiling suspended units. Contractor/OEM to ensure the total load is distributed from point load to distributed load suitable for ceiling load available. Job includes providing ceiling suspended AHU supports / hangers installation. Fully threaded GI bolts will be installed on anchor Fasteners. MS angle plates of requisite size as applicable will be mounted to these hangers by check nuts and spring washers, on which AHU will be provided. Flexible fire retardant double canvass connections, volume control damper Connections designed so as to prevent fan vibration being transmitted to ductwork with noise in conditioned spacePrice should be included of Supply and Installation of Valve Assembly for AHU with microprocessor based control, built in PICV, valve controllers, Thermostats, Butterfly Valves, strainers, drain pumps.Including Return Air sensor with corded remote and its control wiring.Noise Level as per statutory requirements within limits prescribed (upto 55 dB at 3 m distance)AHU Complete with AHU Electric Panel AHU Electric Panel to have electric power provision with incomer & outgoing section Electrical Contractor will provide power to AHU Panel at Incomer Sid e Rest electrical distribution is in HVAC Vendor Scope Provision of spare to be kept in AHU Panel Earthing till AHU Room will be provided by Electrical Contractor Rest earthing distribution is in HVAC Vendor Scope AHU Panel to have Emergency Auxillary Contacts for operation mentioned below AHU Panel to have Emergency Auxillary Contacts for operation mentioned below In case of fire, fire alarm panel will give "1 No." of DC signal to AHU Panel through "Control Module" On receipt of signal from Fire Alarm Panel the AHU Panel trip the AHU The Power Cabling & design between AHU Panel Contacts to Trip AHU is incl. in HVAC Vendor scope Power cabling shall be 4C, copper conductor, armoured cable from Starter Panel to AHU motor with single compression gland. Control cabling, as applicable shall be copper conductor, armoured cable for 2 way valve operation between sensor, actuator etc. Cabling to run within suitable sized cable tray / trunking Necessary temperature sensor to be incl. in cost with associated wiring. AHU Panel to have potential free contacts for taking AHU Incomer Trip Status and on/Off Command on BMS AHU Panel to have potential free contacts for taking AHU Incomer Trip Status and on/Off Command on BMS Including DP Sensor's for filter status and Blower Status.Supply, drain connections, with Drain Pump only for Ceiling suspended. stainless steel (18G) drain pan insulated sandwitch with PUF insulation, auto purge/Ball valve wherever requiredNote:- Civil Foundations for Installation of AHU and AHU Panel (In case AHU Panel is floor mounted) AHU and AHU Panel to be installed on separate civil foundation Item to be quoted as lot. for all AHU Rooms (if required)

4

-

-

... More
Supply, Installation , testing & Commissioning of TFA - 988 CFM, 6.3 TR, 15 mm Static, Ceiling Suspended, Side Discharge, Chilled Water Horizontal/Vertical, Top/Side Discharge, Floor mounted/Ceiling Suspended Air Handling Unit of mentioned capacity. Double skin with blower fan,cooling coil, SS condensate pan and air filters. Housing / Casing to be of Double Skin 43 mm thick, CFC Free PUF injected (Density: 40 kg / Cu. m.) using aluminium extrusion, Thermal break Al profile with thermal barrier The panels shall be made of 1.2 mm galvanized pre coated sheet on out side and 0.8 mm galvanized sheet inside CFC Free Poly Utherane Foam between two metal panels for addittional rigidityCooling coil section with aluminium finned copper tubes (tubes thickness not less than 0.5mm) cooling coil of min 6 row deep. Di-electric union to be used in case of dissimilar metal connection.Multiple Fans as per Air flow requirementFan static calculation to be provided by the Vender before ordering AHU.IEE2 Motor For energy efficiencyMotors to be standard 3 phase 415 V 50 Hz, IP 55Multi row cooling coils having anti-corrossive hydrophilic coating Aluminium finsCoil Face velocity to be 500 fpm. Coil frame shall be SS 304Efficient Air Filters (50 MM thick) equivalent to EU-4 of EN-779 & MERV 8 prefilter specifications. Filter efficiency shall be 90% down to 3.0-10 micron Performance as per ASHRAE 52.1 Easily Cleanable & washableInspection Door with Safety Feature & Limit Switch Weather proof lights inside fan section Fan motor based shall be properly earthed For floor mounted units the base shall be of heavy duty G.I duly powder coated. Flexible Connections between fan outlet & supply air duct as per site requirement Installation of Floor Mounted AHU on anti vibration pads in AHU room at site on civil foundation / blocks, AHU Panel, Cabling, accessories, etc. Item of Civil Foundation is covered under separate item .Installation of Ceiling Suspended AHU on ceiling suspension at site, AHU Panel, Cabling, accessories, etc. For Installation of ceiling suspended units HVAC Contractor to submit for approval GA of typical mounting of ceiling suspended units. Contractor/OEM to ensure the total load is distributed from point load to distributed load suitable for ceiling load available. Job includes providing ceiling suspended AHU supports / hangers installation. Fully threaded GI bolts will be installed on anchor Fasteners. MS angle plates of requisite size as applicable will be mounted to these hangers by check nuts and spring washers, on which AHU will be provided. Flexible fire retardant double canvass connections, volume control damper Connections designed so as to prevent fan vibration being transmitted to ductwork with noise in conditioned spacePrice should be included of Supply and Installation of Valve Assembly for AHU with microprocessor based control, built in PICV, valve controllers, Thermostats, Butterfly Valves, strainers, drain pumps.Including Return Air sensor with corded remote and its control wiring.Noise Level as per statutory requirements within limits prescribed (upto 55 dB at 3 m distance)AHU Complete with AHU Electric Panel AHU Electric Panel to have electric power provision with incomer & outgoing section Electrical Contractor will provide power to AHU Panel at Incomer Sid e Rest electrical distribution is in HVAC Vendor Scope Provision of spare to be kept in AHU Panel Earthing till AHU Room will be provided by Electrical Contractor Rest earthing distribution is in HVAC Vendor Scope AHU Panel to have Emergency Auxillary Contacts for operation mentioned below AHU Panel to have Emergency Auxillary Contacts for operation mentioned below In case of fire, fire alarm panel will give "1 No." of DC signal to AHU Panel through "Control Module" On receipt of signal from Fire Alarm Panel the AHU Panel trip the AHU The Power Cabling & design between AHU Panel Contacts to Trip AHU is incl. in HVAC Vendor scope Power cabling shall be 4C, copper conductor, armoured cable from Starter Panel to AHU motor with single compression gland. Control cabling, as applicable shall be copper conductor, armoured cable for 2 way valve operation between sensor, actuator etc. Cabling to run within suitable sized cable tray / trunking Necessary temperature sensor to be incl. in cost with associated wiring. AHU Panel to have potential free contacts for taking AHU Incomer Trip Status and on/Off Command on BMS AHU Panel to have potential free contacts for taking AHU Incomer Trip Status and on/Off Command on BMS Including DP Sensor's for filter status and Blower Status.Supply, drain connections, with Drain Pump only for Ceiling suspended. stainless steel (18G) drain pan insulated sandwitch with PUF insulation, auto purge/Ball valve wherever requiredNote:- Civil Foundations for Installation of AHU and AHU Panel (In case AHU Panel is floor mounted) AHU and AHU Panel to be installed on separate civil foundation Item to be quoted as lot. for all AHU Rooms (if required)

3

-

-

... More
Supply, Installation , testing & Commissioning of TFA -635 CFM, 4.0 TR, 15 mm Static, Ceiling Suspended, Side Discharge, Chilled Water Horizontal/Vertical, Top/Side Discharge, Floor mounted/Ceiling Suspended Air Handling Unit of mentioned capacity. Double skin with blower fan,cooling coil, SS condensate pan and air filters. Housing / Casing to be of Double Skin 43 mm thick, CFC Free PUF injected (Density: 40 kg / Cu. m.) using aluminium extrusion, Thermal break Al profile with thermal barrier The panels shall be made of 1.2 mm galvanized pre coated sheet on out side and 0.8 mm galvanized sheet inside CFC Free Poly Utherane Foam between two metal panels for addittional rigidityCooling coil section with aluminium finned copper tubes (tubes thickness not less than 0.5mm) cooling coil of min 6 row deep. Di-electric union to be used in case of dissimilar metal connection.Multiple Fans as per Air flow requirementFan static calculation to be provided by the Vender before ordering AHU.IEE2 Motor For energy efficiencyMotors to be standard 3 phase 415 V 50 Hz, IP 55Multi row cooling coils having anti-corrossive hydrophilic coating Aluminium finsCoil Face velocity to be 500 fpm. Coil frame shall be SS 304Efficient Air Filters (50 MM thick) equivalent to EU-4 of EN-779 & MERV 8 prefilter specifications. Filter efficiency shall be 90% down to 3.0-10 micron Performance as per ASHRAE 52.1 Easily Cleanable & washableInspection Door with Safety Feature & Limit Switch Weather proof lights inside fan section Fan motor based shall be properly earthed For floor mounted units the base shall be of heavy duty G.I duly powder coated. Flexible Connections between fan outlet & supply air duct as per site requirement Installation of Floor Mounted AHU on anti vibration pads in AHU room at site on civil foundation / blocks, AHU Panel, Cabling, accessories, etc. Item of Civil Foundation is covered under separate item .Installation of Ceiling Suspended AHU on ceiling suspension at site, AHU Panel, Cabling, accessories, etc. For Installation of ceiling suspended units HVAC Contractor to submit for approval GA of typical mounting of ceiling suspended units. Contractor/OEM to ensure the total load is distributed from point load to distributed load suitable for ceiling load available. Job includes providing ceiling suspended AHU supports / hangers installation. Fully threaded GI bolts will be installed on anchor Fasteners. MS angle plates of requisite size as applicable will be mounted to these hangers by check nuts and spring washers, on which AHU will be provided. Flexible fire retardant double canvass connections, volume control damper Connections designed so as to prevent fan vibration being transmitted to ductwork with noise in conditioned spacePrice should be included of Supply and Installation of Valve Assembly for AHU with microprocessor based control, built in PICV, valve controllers, Thermostats, Butterfly Valves, strainers, drain pumps.Including Return Air sensor with corded remote and its control wiring.Noise Level as per statutory requirements within limits prescribed (upto 55 dB at 3 m distance)AHU Complete with AHU Electric Panel AHU Electric Panel to have electric power provision with incomer & outgoing section Electrical Contractor will provide power to AHU Panel at Incomer Sid e Rest electrical distribution is in HVAC Vendor Scope Provision of spare to be kept in AHU Panel Earthing till AHU Room will be provided by Electrical Contractor Rest earthing distribution is in HVAC Vendor Scope AHU Panel to have Emergency Auxillary Contacts for operation mentioned below AHU Panel to have Emergency Auxillary Contacts for operation mentioned below In case of fire, fire alarm panel will give "1 No." of DC signal to AHU Panel through "Control Module" On receipt of signal from Fire Alarm Panel the AHU Panel trip the AHU The Power Cabling & design between AHU Panel Contacts to Trip AHU is incl. in HVAC Vendor scope Power cabling shall be 4C, copper conductor, armoured cable from Starter Panel to AHU motor with single compression gland. Control cabling, as applicable shall be copper conductor, armoured cable for 2 way valve operation between sensor, actuator etc. Cabling to run within suitable sized cable tray / trunking Necessary temperature sensor to be incl. in cost with associated wiring. AHU Panel to have potential free contacts for taking AHU Incomer Trip Status and on/Off Command on BMS AHU Panel to have potential free contacts for taking AHU Incomer Trip Status and on/Off Command on BMS Including DP Sensor's for filter status and Blower Status.Supply, drain connections, with Drain Pump only for Ceiling suspended. stainless steel (18G) drain pan insulated sandwitch with PUF insulation, auto purge/Ball valve wherever requiredNote:- Civil Foundations for Installation of AHU and AHU Panel (In case AHU Panel is floor mounted) AHU and AHU Panel to be installed on separate civil foundation Item to be quoted as lot. for all AHU Rooms (if required)

6

-

-

... More
Supply, Installation, testing & Commissaioning of 4 way Chilled water Cassette Units with Valve Assembly Cassette Units with microprocessor based control, built in PICV, valve controllers, Thermostats, Butterfly Valves, strainers, drain pumps, drain pan. Cassette shall be driven on single phase 230V, AC, 50 Hz. Supply. Shall have direct driven fan driven assembly with 3 speed motor, filter, mounting accessories, vibration isolators etc. Motor shall be protected with thermal overload protection with proper heat dissipation assembly. Cost is incl. of cordless remote control. Shall have provision for hard wired contacts monitoring through BMS Electrical Contractor shall provide the MCB/ switch socket near to indoor unit. Power Copper conducting cabling from MCB/ switch socket to indoor unit including supply & fixing of plug top if required to match the receptacle provided. (Avg. Length 5 Rmt.) 4 WAY CASSETTE UNIT 2.6 TR / 1000 CFM

2

-

-

... More
Supply, Installation, testing & Commissaioning of 4 way Chilled water Cassette Units with Valve Assembly Cassette Units with microprocessor based control, built in PICV, valve controllers, Thermostats, Butterfly Valves, strainers, drain pumps, drain pan. Cassette shall be driven on single phase 230V, AC, 50 Hz. Supply. Shall have direct driven fan driven assembly with 3 speed motor, filter, mounting accessories, vibration isolators etc. Motor shall be protected with thermal overload protection with proper heat dissipation assembly. Cost is incl. of cordless remote control. Shall have provision for hard wired contacts monitoring through BMS Electrical Contractor shall provide the MCB/ switch socket near to indoor unit. Power Copper conducting cabling from MCB/ switch socket to indoor unit including supply & fixing of plug top if required to match the receptacle provided. (Avg. Length 5 Rmt.) 4 WAY CASSETTE UNIT3.2 TR / 1200 CFM

40

-

-

... More
Supply, Installation, testing & Commissaioning of Control Cabling between PICV & actuators Control cabling, as applicable shall be copper conductor, armoured cable for PICV operation between sensor, actuator etc. Vendor to evaluate distance between components (Average length 15 meters) and in no case separate cost shall be paid for same

1

-

-

... More
Providing Rigid PVC Piping 6 kg/cm2 with accessories, fittings, traps, reducer etc & Civil Supports, clamps etc. as required.Drain Piping to be duly insulated with 9 mm 60 kg/m3 densityThick Nitrile Rubber Pipe Sections & cost of same is incl. in this line item.For laying the pipes drilling, chipping & minor civil work is incl. in scope for concealing the drain pipe 25MM Dia

420

-

-

... More
Providing Rigid PVC Piping 6 kg/cm2 with accessories, fittings, traps, reducer etc & Civil Supports, clamps etc. as required.Drain Piping to be duly insulated with 9 mm 60 kg/m3 densityThick Nitrile Rubber Pipe Sections & cost of same is incl. in this line item.For laying the pipes drilling, chipping & minor civil work is incl. in scope for concealing the drain pipe 32 mm Dia

280

-

-

... More
Providing Rigid PVC Piping 6 kg/cm2 with accessories, fittings, traps, reducer etc & Civil Supports, clamps etc. as required.Drain Piping to be duly insulated with 9 mm 60 kg/m3 densityThick Nitrile Rubber Pipe Sections & cost of same is incl. in this line item.For laying the pipes drilling, chipping & minor civil work is incl. in scope for concealing the drain pipe 40 mm Dia

70

-

-

... More
Providing starter panel cum control panel, Incoming & Outgoing Switchgear of OEM recommended sizes, inbuilt -protection against O/L, S/C, Indicating lamps, NO-NC contacts.SITC of DIDW class I CENTRIFUGAL FANS with cabinet for ventilation system. Each fan shall be complete with totally enclosed fan cooled motor, belt drive, pulley mounted on motor & fan shaft, belt guard, motor mount, casing and vibration isolators. Motor shall be suitable for 415 +_ 10% volts, 50 cycles, 3 phase AC supply and high efficiency. Efficiency of all fans shall be greater than 65%.Cowl piece, Bird Mesh Screen, Rain Cowl, Gravity Louvers to be considered Copper conductor power cabling from starter panel to fan including supply & fixing of plug top if required. Cost is inclusive of both end termination using copper lugs & single compression Brass gland. (Avg. Cable Length 20 Rmt.)1850 CFM, 15 mm static

2

-

-

... More
Providing starter panel cum control panel, Incoming & Outgoing Switchgear of OEM recommended sizes, inbuilt -protection against O/L, S/C, Indicating lamps, NO-NC contacts.SITC of DIDW class I CENTRIFUGAL FANS with cabinet for ventilation system. Each fan shall be complete with totally enclosed fan cooled motor, belt drive, pulley mounted on motor & fan shaft, belt guard, motor mount, casing and vibration isolators. Motor shall be suitable for 415 +_ 10% volts, 50 cycles, 3 phase AC supply and high efficiency. Efficiency of all fans shall be greater than 65%.Cowl piece, Bird Mesh Screen, Rain Cowl, Gravity Louvers to be considered Copper conductor power cabling from starter panel to fan including supply & fixing of plug top if required. Cost is inclusive of both end termination using copper lugs & single compression Brass gland. (Avg. Cable Length 20 Rmt.) 840 CFM, 10 mm static

1

-

-

... More
Providing starter panel cum control panel, Incoming & Outgoing Switchgear of OEM recommended sizes, inbuilt -protection against O/L, S/C, Indicating lamps, NO-NC contacts.SITC of DIDW class I CENTRIFUGAL FANS with cabinet for ventilation system. Each fan shall be complete with totally enclosed fan cooled motor, belt drive, pulley mounted on motor & fan shaft, belt guard, motor mount, casing and vibration isolators. Motor shall be suitable for 415 +_ 10% volts, 50 cycles, 3 phase AC supply and high efficiency. Efficiency of all fans shall be greater than 65%.Cowl piece, Bird Mesh Screen, Rain Cowl, Gravity Louvers to be considered Copper conductor power cabling from starter panel to fan including supply & fixing of plug top if required. Cost is inclusive of both end termination using copper lugs & single compression Brass gland. (Avg. Cable Length 20 Rmt.) 720 CFM, 10 mm static

1

-

-

... More
Providing starter panel cum control panel, Incoming & Outgoing Switchgear of OEM recommended sizes, inbuilt -protection against O/L, S/C, Indicating lamps, NO-NC contacts.SITC of DIDW class I CENTRIFUGAL FANS with cabinet for ventilation system. Each fan shall be complete with totally enclosed fan cooled motor, belt drive, pulley mounted on motor & fan shaft, belt guard, motor mount, casing and vibration isolators. Motor shall be suitable for 415 +_ 10% volts, 50 cycles, 3 phase AC supply and high efficiency. Efficiency of all fans shall be greater than 65%.Cowl piece, Bird Mesh Screen, Rain Cowl, Gravity Louvers to be considered Copper conductor power cabling from starter panel to fan including supply & fixing of plug top if required. Cost is inclusive of both end termination using copper lugs & single compression Brass gland. (Avg. Cable Length 20 Rmt.) 660 CFM, 15 mm static

4

-

-

... More
Providing starter panel cum control panel, Incoming & Outgoing Switchgear of OEM recommended sizes, inbuilt -protection against O/L, S/C, Indicating lamps, NO-NC contacts.SITC of DIDW class I CENTRIFUGAL FANS with cabinet for ventilation system. Each fan shall be complete with totally enclosed fan cooled motor, belt drive, pulley mounted on motor & fan shaft, belt guard, motor mount, casing and vibration isolators. Motor shall be suitable for 415 +_ 10% volts, 50 cycles, 3 phase AC supply and high efficiency. Efficiency of all fans shall be greater than 65%.Cowl piece, Bird Mesh Screen, Rain Cowl, Gravity Louvers to be considered Copper conductor power cabling from starter panel to fan including supply & fixing of plug top if required. Cost is inclusive of both end termination using copper lugs & single compression Brass gland. (Avg. Cable Length 20 Rmt.) 600 CFM, 10 mm static

3

-

-

... More
Providing starter panel cum control panel, Incoming & Outgoing Switchgear of OEM recommended sizes, inbuilt -protection against O/L, S/C, Indicating lamps, NO-NC contacts.SITC of DIDW class I CENTRIFUGAL FANS with cabinet for ventilation system. Each fan shall be complete with totally enclosed fan cooled motor, belt drive, pulley mounted on motor & fan shaft, belt guard, motor mount, casing and vibration isolators. Motor shall be suitable for 415 +_ 10% volts, 50 cycles, 3 phase AC supply and high efficiency. Efficiency of all fans shall be greater than 65%.Cowl piece, Bird Mesh Screen, Rain Cowl, Gravity Louvers to be considered Copper conductor power cabling from starter panel to fan including supply & fixing of plug top if required. Cost is inclusive of both end termination using copper lugs & single compression Brass gland. (Avg. Cable Length 20 Rmt.) 480 CFM, 10 mm static

5

-

-

... More
Providing starter panel cum control panel, Incoming & Outgoing Switchgear of OEM recommended sizes, inbuilt -protection against O/L, S/C, Indicating lamps, NO-NC contacts.SITC of DIDW class I CENTRIFUGAL FANS with cabinet for ventilation system. Each fan shall be complete with totally enclosed fan cooled motor, belt drive, pulley mounted on motor & fan shaft, belt guard, motor mount, casing and vibration isolators. Motor shall be suitable for 415 +_ 10% volts, 50 cycles, 3 phase AC supply and high efficiency. Efficiency of all fans shall be greater than 65%.Cowl piece, Bird Mesh Screen, Rain Cowl, Gravity Louvers to be considered Copper conductor power cabling from starter panel to fan including supply & fixing of plug top if required. Cost is inclusive of both end termination using copper lugs & single compression Brass gland. (Avg. Cable Length 20 Rmt.) 360 CFM, 10 mm static

5

-

-

... More
Supply Installation testing and commissioning of EXHAUST/ FRESH AIR FAN OF TUBE AXIAL TYPE (Single Speed Fan) as per technical specification and drawing, min. IE-3 Motor with class F isulation. The total Fan efficiency shall be min. 70%. The noise level shall not be more than 70 DBa @ 3m. The minimum external fan static shall as specified below. The price shall include the Fire rated Canvas connection, Isolator for exhaust air fans required for maintenance purpose.All unit shall be provided with supports, Mild Steel Mounting Frame / platform for support and maintenance space (wherever necessary) with required cable from starter panel till ventilation fan including end termination, max. cable length to be considered upto 10 Rmt extra length of cable will be paid as per BOQ rate. Following parameter need to consider in fan selection. 1.Selection by Performance Criteria ( Sound,Efficiencyy of Fans), 2.Fans Shall be AMCA Certified for Sound and Air Performance 3.Fans Casing shall be made out of Minimum 220 GSM GI SheetsCapacity - 5100 CFM, 20 mm ESP, 2.0 kW ( For Exhaust Air)

1

-

-

... More
Supply Installation testing and commissioning of EXHAUST/ FRESH AIR FAN OF TUBE AXIAL TYPE (Single Speed Fan) as per technical specification and drawing, min. IE-3 Motor with class F isulation. The total Fan efficiency shall be min. 70%. The noise level shall not be more than 70 DBa @ 3m. The minimum external fan static shall as specified below. The price shall include the Fire rated Canvas connection, Isolator for exhaust air fans required for maintenance purpose.All unit shall be provided with supports, Mild Steel Mounting Frame / platform for support and maintenance space (wherever necessary) with required cable from starter panel till ventilation fan including end termination, max. cable length to be considered upto 10 Rmt extra length of cable will be paid as per BOQ rate. Following parameter need to consider in fan selection. 1.Selection by Performance Criteria ( Sound,Efficiencyy of Fans), 2.Fans Shall be AMCA Certified for Sound and Air Performance 3.Fans Casing shall be made out of Minimum 220 GSM GI Sheets Capacity - 4350 CFM, 20 mm ESP, 2.0 kW ( For Fresh Air)

1

-

-

... More
Supply of wall mounted AXIAL TYPE PROPELLER EXHAUST AIR FAN in accordance with and meeting the intents & specifications & drawings complete with high efficiency, 50Hz, single phase 220 V +/- 5% external rotor Motor, high grade GSS blade, statically & dynamically balanced Fan, Low noise, with Plug top. The dB level shall be not more than 45 dB at 3 meter. (Avg. Length 5 Rmt.) 900 CFM

4

-

-

... More
Supply of wall mounted AXIAL TYPE PROPELLER EXHAUST AIR FAN in accordance with and meeting the intents & specifications & drawings complete with high efficiency, 50Hz, single phase 220 V +/- 5% external rotor Motor, high grade GSS blade, statically & dynamically balanced Fan, Low noise, with Plug top. The dB level shall be not more than 45 dB at 3 meter. (Avg. Length 5 Rmt.) 1100 CFM

1

-

-

... More
Providing and applying of acoustic insulation for air ducts with 25mm thick, 48 kg/cu.m fiber glass faced with RP tissue and covered with 26 SWG perforated aluminium sheets complete.

460

-

-

... More
Providing adhesive thermal insulation for supply return air duct with 19mm nitrile rubber insulation having R-value as per the prevailing provisions in ECBC-2017.

1850

-

-

... More
Supply, installation, balancing and commissioning of factory fabricated GSS sheet metal Rectangular/Round ducting complete with neoprene rubber gaskets, elbows, splitter dampers, vanes, hangers, supports etc. as per approved drawings and specifications of following sheet thickness complete as required. All Exposed Ventilation Ducts , Dampers & Supports shall be with Anti Corrossive painting and price should be extra.GI- 24 gauge(Thickness 0.63mm sheet)

1760

-

-

... More
Supply, installation, balancing and commissioning of factory fabricated GSS sheet metal Rectangular/Round ducting complete with neoprene rubber gaskets, elbows, splitter dampers, vanes, hangers, supports etc. as per approved drawings and specifications of following sheet thickness complete as required. All Exposed Ventilation Ducts , Dampers & Supports shall be with Anti Corrossive painting and price should be extra.GI- 22 gauge(Thickness 0.8mm sheet)

440

-

-

... More
Supply, installation, testing and commissioning of manually operated, opposed blade, duct mounted, flanged volume control dampers of required sizes in GI construction with operating mechanism, mounting arrangement, rubber refrigerant kits etc. complete.

8

-

-

... More
Supplying and installing of collar damper of galvanised iron material of upto 120 microns for anti corrosive resistance for supply air grill of suitable size.

35

-

-

... More
Fire Dampers in supply air duct / main branch and return air path as and where required size including control wiring, the damper shall be motorized and spring return so as to close the damper in the event of Power failure automatically and open the same in case of power being restored. The Spring return action shall be inbuilt mechanism and not externally mounted. The damper shall also be closed in the event of fire signal complete as required as per specification.

12

-

-

... More
Fire Actuator Supplying, fixing testing commissioning of Fire Actuator in supply air duct / main branch and return air path as and where required size including control wiring, the damper shall be motorized and spring return so as to close the damper in the event of Power failure automatically and open the same in case of power being restored. The Spring return action shall be inbuilt mechanism and not externally mounted. The damper shall also be closed in the event of fire signal complete as required as per specification.

27

-

-

... More
SITC of 'BACK DRAFT DAMPER / GRAVITY DAMPERS - NON-FIRE RATED , NRD for fan discharge / outlet back draft dampers of 18G Casing and 22G Blade (with rest supports) GSS Construction complete with frame & necessary civil work for fixing.

4

-

-

... More
Supply, Installation, Testing & Commissioning of Jet Nozzel suitable for Supply Air comprising of an adjustable centre cone and coupling sleeve made of aluminium sheet duly epoxy painted with approved color. The Jet Diffuser shall be fitted with a galvanised steel installation frame and the sleeve shall incoporate a foam-rubber gasket for Airtight sealing. The centre cone should be adjustable for balancing and with a locking arrangement to maintain the desired flow rate.Jet Nozzel Size- 400 mm Dia

72

-

-

... More
Supplying and erecting aluminium powder coated linear grill of suitable size for width length without collar dampers having matching colour with the existing false ceiling and suitable for deflection of 15/30/45°.

120

-

-

... More
SITC of Non Vision transfer grilles in extruded aluminium comprising of a non vision door grille on one side and complete with sliding frame on the opposing side. The color shall match the interior requirements. Colour as per architect choice. Thickness assembly as per door requirement

10

-

-

... More
SITC of Disc Valves made out of Sheet Steel powder coated with fully adjustable inner core for regulating volume for Exhaust 150mm dia

145

-

-

... More
Extruded aluminum exhaust air/fresh air rain protection louvers with GI Bird Screen as per specifications. The louvers shall be anodized aluminum as per apporval of the Architect and offering free area not less than 60% of gross face area.

5

-

-

... More
Supplying, erecting & terminating FR XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V,with folloowing size. copper/Aluminium conductor complete erected with glands & lugs, on wall/ trusses/ pole or laid in provided trench/ pipe as per specification no. CB-LT/CU _ 4C x 4 CU

300

-

-

... More
Supplying, erecting & terminating FR XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V,with folloowing size. copper/Aluminium conductor complete erected with glands & lugs, on wall/ trusses/ pole or laid in provided trench/ pipe as per specification no. CB-LT/CU _4C x 6 CU

5

-

-

... More
Supplying, erecting & terminating FR XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V,with folloowing size. copper/Aluminium conductor complete erected with glands & lugs, on wall/ trusses/ pole or laid in provided trench/ pipe as per specification no. CB-LT/CU _4C x 10 CU

5

-

-

... More
Supplying, erecting & terminating FR XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V,with folloowing size. copper/Aluminium conductor complete erected with glands & lugs, on wall/ trusses/ pole or laid in provided trench/ pipe as per specification no. CB-LT/CU _4C x 16 CU

40

-

-

... More
Supplying, erecting & terminating FR XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V,with folloowing size. copper/Aluminium conductor complete erected with glands & lugs, on wall/ trusses/ pole or laid in provided trench/ pipe as per specification no. CB-LT/CU _3.5C x 25 AL

5

-

-

... More
Supplying, erecting & terminating FR XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V,with folloowing size. copper/Aluminium conductor complete erected with glands & lugs, on wall/ trusses/ pole or laid in provided trench/ pipe as per specification no. CB-LT/CU _4C x 300 CU FLEXIBLE (2 RUN'S FOR CHILLER)

75

-

-

... More
Supply and installation of following sizes of pre-fabricated Hot dipped GI perforated type cable tray along with coupler plates, 90 bends, Tees, necessary nut-bolts / washers and other hardware etc. including providing / fixing of necessary supports. 50mm (W) x 25mm (H) x 2mm (THK) cable trays

50

-

-

... More
Supply and installation of following sizes of pre-fabricated Hot dipped GI perforated type cable tray along with coupler plates, 90 bends, Tees, necessary nut-bolts / washers and other hardware etc. including providing / fixing of necessary supports. 100mm (W) x 25mm (H) x 2mm (THK) cable trays

30

-

-

... More
Supply and installation of following sizes of pre-fabricated Hot dipped GI perforated type cable tray along with coupler plates, 90 bends, Tees, necessary nut-bo lts / washers and other hardware etc. including providing / fixing of necessary supports. 150mm (W) x 50mm (H) x 2mm (THK) cable trays

30

-

-

... More
Supply and installation of following sizes of pre-fabricated Hot dipped GI perforated type cable tray along with coupler plates, 90 bends, Tees, necessary nut-bolts / washers and other hardware etc. including providing / fixing of necessary supports. 300mm (W) x 50mm (H) x 2mm (THK) cable trays

60

-

-

... More
Supply and installation of following sizes of pre-fabricated Hot dipped GI perforated type cable tray along with coupler plates, 90 bends, Tees, necessary nut-bolts / washers and other hardware etc. including providing / fixing of necessary supports. 450mm (W) x 50mm (H) x 2mm (THK) cable trays

50

-

-

... More
Supply, Installation, Testing & Commissioning of GI Earth strip including necessary accessories, clamping to walls, cable tray etc. as required 25 x 6 GI strip

100

-

-

... More
Supply, Installation, Testing & Commissioning of GI Earth strip including necessary accessories, clamping to walls, cable tray etc. as required 25 x 6 GI strip

100

-

-



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.