Goa Tourism Development Corporation Limited Tender

View complete overview of Goa GTDC Tender

Goa Tourism Development Corporation Limited - GTDC Tender

Works
Civil And Construction
Road Construction
Eprocure
Opening Date15 Dec 2022
Closing Date28 Dec 2022
Tender Amount₹ 8,61,92,856 
Notes
Download

Costs

  • EMD

    ₹ 17,23,900
  • Document Cost

    ₹ 20,000
  • Tender Fee

    ₹ 6,000

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
Refilling the pipeline/foundation trenches plinth sides, foundation etc. with available excavated earth in layers not exceeding 20 cm depth consolidating each layer ramming and watering lead upto 50 M and all lifts and disposal of surplus earth as directed by Engineer .

333

-

-

... More
Rubble packing with hard laterite stone under floors including watering ramming and consolidating etc. in pipeline trenches and other foundations complete.

1712

-

-

... More
Pre-cast cement concrete solid block masonry of compressive strength 70 kg / cm2 in cement mortar 1:4 (1 cement : 4 corase sand ) in foundation and plinth size of blocks (30 x 20 x 15)

563

-

-

... More
Providing & laying cement concrete 1:2:4 (1 cement: 2 coarse sand: 4 graded granitic or basaltic stone aggregate 20 mm. nominal size) excluding cost of centering, shuttering and finishing in: All work up to Plinth level

1103

-

-

... More
Providing and laying up to floor 5 level cement concrete 1 : 2 : 4 ( 1 Cement : 2 coarse sand : 4 graded granitic or basaltic stone aggregate 20 mm nominal size) including smooth finishing to exposed surfaces ,cement mortar 1:3 ( 1 cement : 3 fine sand ) including centering and shuttering etc. in string courses ,coping ,bed plate,anchor block,plain window sills and the like.

38

-

-

... More
Providing and laying in position ready mixed concrete (RMC) manufactured in fully automatic batching plant and transported to site of work in transit mixer for a lead upto 10kms having continious agitated mixer, manufactured as per mix design of specified grade for reinforced cement concrete work including pumping of R.M.C., from the transit mixer to the site of laying, excluding the cost of centering, shuttering, finishing and reinforcement including the cost of admixtures in recommended porportions as per IS : 9103 to accelerate/retard setting of concrete, improve workability without imparing strength and durability as per the directions of the engineer-in-charge. All works upto floor V level. M-25grade of concrete

926

-

-

... More
Centering and shuttering including strutting, propping, & removal of form for Foundation, footings, bases of columns

5943

-

-

... More
Providing TMT steel reinforcement bars of SAIL, TATA, VIZAG made only (Confirming to IS 1786 of 1986) for RCC work (conforming to I.S. 1786 of 1986) including bending, binding & placing in position in all the floors along with the factory made precast concrete cover blocks of specified sizes whose compressive strength is not less than that of surrounding concrete in the structural member. Minimum Grade of Steel - Fe 450

69450

-

-

... More
Providing and laying factory made Shot blasted cement concrete interlocking paver block of minimum M35 grade made by heavy duty block making machine with strong vibratory compaction and of aprpoved size and design / shape laid in 50 mm thick compacted bed of coarse sand, filling the joints with coarse sand, etc. all complete as per the direction of Engineer.- in I, Wave, Rectangular, Square etc. shapes. The products should comply to IS 15658:2006 and manfucatured by ISO9001: 2008 certified plant. The shot blasting should be done using 0.4-0.5mm dia steel shots with a speed of 3200 rpm. a 60 mm thick in all colours except grey (M35 grade)

1365

-

-

... More
Providing and laying factory made Shot blasted cement concrete interlocking paver block of minimum M35 grade made by heavy duty block making machine with strong vibratory compaction and of aprpoved size and design / shape laid in 50 mm thick compacted bed of coarse sand, filling the joints with coarse sand, etc. all complete as per the direction of Engineer.- in I, Wave, Rectangular, Square etc. shapes. The products should comply to IS 15658:2006 and manfucatured by ISO9001: 2008 certified plant. The shot blasting should be done using 0.4-0.5mm dia steel shots with a speed of 3200 rpm. b 60 mm thick in Grey colour (M35 grade)

585

-

-

... More
Providing and laying factory made Shot blasted cement concrete interlocking paver block of minimum M35 grade made by heavy duty block making machine with strong vibratory compaction and of aprpoved size and design / shape laid in 50 mm thick compacted bed of coarse sand, filling the joints with coarse sand, etc. all complete as per the direction of Engineer.- in I, Wave, Rectangular, Square etc. shapes. The products should comply to IS 15658:2006 and manfucatured by ISO9001: 2008 certified plant. The shot blasting should be done using 0.4-0.5mm dia steel shots with a speed of 3200 rpm. c 80 mm thick in all colours except grey (M40 grade)

3798

-

-

... More
Providing and laying factory made Shot blasted cement concrete interlocking paver block of minimum M35 grade made by heavy duty block making machine with strong vibratory compaction and of aprpoved size and design / shape laid in 50 mm thick compacted bed of coarse sand, filling the joints with coarse sand, etc. all complete as per the direction of Engineer.- in I, Wave, Rectangular, Square etc. shapes. The products should comply to IS 15658:2006 and manfucatured by ISO9001: 2008 certified plant. The shot blasting should be done using 0.4-0.5mm dia steel shots with a speed of 3200 rpm. d 80 mm thick in grey colour (M40 grade)

1628

-

-

... More
Precast plain cement chequered tiles 22 mm thick of required shades laid in floors, treads of steps and landing on 20 mm thick bed of Cement mortar 1:4 (1cement : 4 coarse sand) jointed with neat cement slurry mixed with pigment to match the shade of tiles including rubbing and cleaning etc. complete. c Dark shades using ordinary cement

2431

-

-

... More
Supplying and fixing Pre-cast cement concrete kerb-stones(factory made,the factory should be ISO certified and registered under Dirctorate of Industries, Govt. of India) of M-20 with 20 mm nominal size granitic/basaltic aggregate properly consolidated by mechanical plat-form and vibrators with smooth finish including fixing at site complete as per specification. c Size 60 cm L x45 cm H x 15 cm T

1400

-

-

... More
Providing and fixing coloured ceramic tiles (Bell or equivalent) of 8" x 12" size and 6 mm thick in skirting and dados on 12 mm thick cement plaster 1:3 (1 cement : 3 coarse sand) and jointed with cement slurry complete.

405

-

-

... More
18mm cement plaster in two coats under layer 12mm thick cement plaster 1:5 ( 1 cement : 5 coarse sand) and top layer 6mm thick with cement plaster 1: 3 (1 cement : 3 coarse sand) finished with sponge.

4830

-

-

... More
Extra for providing and mixing water proofing material proportion recommended by the manufacturers. (a)12mm cement plaster 1: 3 (1 cement : 3 sand)

4148

-

-

... More
Painting three or more coats with acryllic exterior paint of approved brand and manufacture (such as weather shield,APEX) including applying one coat of cement primer and one coat of surface treatment etc. complete.

1803

-

-

... More
Neat Cement punning

458

-

-

... More
Carting away unwanted excavated material such as soil, lime, moorum, building rubbish (RCC debris, masonary debris, woodwork, door & windows, tiles etc), laterite stone, ordinary rock etc. from site lead of 5km including all loading & unloading charges ( A ) ( by mechnaical Automative Transport ) Contractor should arrange land for dispose up these material at his own cost Lead upto 5 km. Contractor should quote the rate considering salvage value of mentioned material. All statutory approval will be taken by Contractor

4714

-

-

... More
Demolishing cement concrete 1:4:8 or leaner mix including disposal of material within 50 m lead

446

-

-

... More
Demolishing laterite stone masonry in cement mortar including stacking of serviceable material & disposal of unserviceable material within 50 mts. lead.

270

-

-

... More
Dismantling the tile work in floors and roofs laid in cement including stacking of materials within 50 meters lead for thickness of tiles 10mm to 25mm.

1500

-

-

... More
Taking out existing CC interlocking paver blocks from footpath/ central verge, including removal of rubbish etc., disposal of unserviceable material and stacking of serviceable material within 50 metre lead as per direction of Engineer-in-Charge.

2600

-

-

... More
Supplying and fixing of Precast RCC slabs(factory made,the factory should be ISO certified and registered under Dirctorate of Industries, Govt. of India) at site in concrete Grade of M-25 with 20 mm nominal size Granitic or basaltic aggregate, consolidated by means of mechanical platform, vibration etc. with lifting hooks of M.s. 10mm bars and PVC cups including cost of reincforcement, Certificate from manufacturer shall be produced indicating grade of concret and minimum content of steel in the product along with 5 year free replacement warranty in case of breakage complete and as directed by Engineer -in -charge. b Size 900 x 400 x 100 mm with steel reinforcement not less than 5 kg per unit -12 T capacity.

1250

-

-

... More
Providing and fixing weepholes with rigid PVC make laid in position with a required slope and level while layingpipes of approved the concrete of retaining wall,wing wall and earth retainig structure complete as directed by the Engineer in charge. A 110 mm dia

96

-

-

... More
Providing of Road circle and fixing fiber Sculpture (FRP/GRP/ ANY OTHER MATERIAL SPECIFIED BY VENDOR) alongwith fabricating a rigid skeletal frame work by welding steel bars/weld mesh as per the desired size, shape and profile of the finished structure .Finish should be simillar to the photofeatures approved by the Architect. Rate should be inclusive of Scaffolding , reinforcement welding, framework as per structural design. Work should be as per detail design & drawing and as directed by Engineer -in -charge.

2

-

-

... More
Providing at store or site work non-pressure RCC pipes of with collar joints conforming to IS:458-2003 revised as per amendment No.11 , including freight, carting, loading, unloading, stacking etc. complete. I NP2 Class. F 250 mm dia.

1500

-

-

... More
Conveying carefully from stack at site, 250m from both sides rolling and lowering into trenches, laying and jointing true to line and level, RCC spun pressure and non pressure pipes of various classes, specials including collar and perfect linking of joint with jack to correct position including cost of jointing material in cement mortar 1:2, necessary hydraulic testing, curing of cement mortar etc. complete. c 250 mm nominal dia.

1500

-

-

... More
Providing and fixing stainless steel (Grade 304) railing made of Hollow tubes, channels, plates etc.with hairline finish, including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners, stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer, ( for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.).

10120

-

-

... More
ELECTRICAL WORKS

-

-

-

... More
SITC of 60 watt Decorative streetlight Light Fitting to be mounted at 4.2 mt height (Equivalent or Kesslec Beluga). Electrical Class I high pressure die cast aluminium body with pc protector(for optimal luminous flux, IK 09 impact resistance( Confirmed with Third party NABL approved lab report)  IP 66 optical & control gear compartments with direct access to control gear, suitable for a horizontal / vertical mounting (Ø60mm).The luminaire is equipped with universal post of /horizontal adapter with inclination from -20 to 15 degree in steps of 2.5 degree.  Each LED with a specific lens for uniform photometric distribution. The luminaire must be equipped with balance device ,Automatic power off switch ,respiratory system and tool free buckle for ease in operation. The luminaire shall be fitted with a vent for pressure equalization and a spirit level indicator with respect to the horizontal plane. The luminaire shall have a CCT of 3000K(As per GTDC) with Luminaire efficacy of 130 lm /watt at 3000 k and 7800 system level ( Comply with LM79 report from Third party NABL approved lab as per ANSI  and Colour Rendering Index 70, a driver (efficiency 85%) with internal surge protection of 4 kV and external surge protection of 20 KV . Power Factor 0.95, a residual flux of 70% (L70) @ 50,000 hours at Ta 50 degree.

65

-

-

... More
SITC of 120 watt Decorative streetlight Light Fitting to be mounted at 8.1 mt height (Equivalent or Kesslec Beluga). Electrical Class I high pressure die cast aluminium body with pc protector(for optimal luminous flux, IK 09 impact resistance( Confirmed with Third party NABL approved lab report)  IP 66 optical & control gear compartments with direct access to control gear, suitable for a horizontal / vertical mounting (Ø60mm).The luminaire is equipped with universal post of /horizontal adapter with inclination from -20 to 15 degree in steps of 2.5 degree.  Each LED with a specific lens for uniform photometric distribution. The luminaire must be equipped with balance device ,Automatic power off switch ,respiratory system and tool free buckle for ease in operation. The luminaire shall be fitted with a vent for pressure equalization and a spirit level indicator with respect to the horizontal plane. The luminaire shall have a CCT of 3000K(As per GTDC ) with Luminaire efficacy of 130 lm /watt at 3000 k and 15600 system level ( Comply with LM79 report from Third party NABL approved lab as per ANSI  and Colour Rendering Index 70, a driver (efficiency 85%) with internal surge protection of 4 kV and external surge protection of 20 KV . Power Factor 0.95, a residual flux of 70% (L70) @ 50,000 hours at Ta 50 degree.

65

-

-

... More
SITC of 8.1 mt/4.2 mt differential height double arm Pole ( Kesslec style pole or Equivalent). The streetlight pole shall be of ‘composite’ construction designed to withstand specified ‘dead load’ pertaining to the luminaire and its mounting accessories and ‘wind load’ corresponding to a basic wind speed of 169kmph without any deformation or damage to the structure. The pole should be designed as per the stipulations of standard EN40 to establish its structural suitability under ‘serviceability’ and ‘ultimate limit state’ conditions. The Pole Shaft should be fabricated out of Steel tube of grade YSt 240 and batch test reports for chemical and mechanical properties of material should be submitted along with the bid. Structurally designed base plate of Steel A36/A572-50 or equivalent should be welded with the pole shaft. The welding shall be of high quality, carried out by qualified welders using approved welding procedures and tested for its quality through NDT method, such as DP Test. The pole shall be provided with an opening at the bottom with removable cover for providing connectors, MCB, etc. Appropriate reinforcement shall be provided to compensate for the loss of section at this point to ensure overall structural stability of the pole under specified operating conditions. The pole shaft structure shall be hot dip galvanized through single dip process as per ASTM A123 and minimum average coating shall not be less than 65 microns. No mechanical operation, such as welding, drilling, etc. should be carried out on the pole structure post hot dip galvanizing. Poles using pre galvanized steel tubes or hot dip galvanized through double dip process are not acceptable. Complete pole shall be treated with high quality primer and thereafter coated with Marine grade Polyurethane paint to minimum average DFT of 70 microns. The painting shall be carried out by experienced and trained technicians using proven and established painting procedure. Only ‘controlled’ paint drying process shall be used to ensure proper adhesion and finish of the paint. The pole should be of large section at the base at a height of 2.8 mt made up of tapered fabictaed sheet of 3mm the. Welded with pipe dia. through which one double ended branch coming out of dia 60 mm Complete with all required accessories like Junction box with 15A Input output connectors , 0.5 - 6 A C curve SP MCB for suitable for each light fittings 3 Core 1.5 Sq. mm Cu Flex. cable for light fitting from Junction box to Light fittings and its termination of cables should be made using with proper lugs ,Pole will Be Painted with P U Paint as per GTDC color choice .etc.

65

-

-

... More
SITC of 75 watt Decorative streetlight Light Fitting to be mounted on 7 mt pole on single side. LED Street light luminaire 75-80 watt ( BIS certified luminaire with R number and BIS certificate) with highly efficient temperature resistant integrated lenses PC/Glass protector IK08 ( Comply with IS 10322 report fromThird party NABL approved lab) report for asymmetric light distribution. The luminaire with a body of high pressure die cast aluminium painted grey, separate IP66 optical and control gear compartments ( Comply with IS 10322 report from Third party NABL approved lab) suitable for horizontal mounting of 60mm diameter pipe, luminaire efficacy of Minimum 120lm/W, light colour Neutral white(As per GTDC)( Comply with LM 79 report from Third party NABL approved lab , at correlated colour temperature (CCT) of 4000K(As per GTDC) ( Comply with LM79 report from Third party NABL approved lab) As per ANSI general colour rendering index (CRI) 70, mean rated service life of 50,000 hours at L70, electrical Class I, rated voltage 240V, Power Factor ≥ 0.95, with drivers’ internal surge protection of 4/4 kV, a surge protection device (SPD) of 10/10 kV .

60

-

-

... More
SITC of 7 mt octagonal pole with 1 mt single arm bracket Poles shall be continuously tapered OCTAGONAL cross section, presenting a good and pleasing appearance and based on proven design conforming to international standards, to give an assured performance, and reliable service. The pole shall be suitable for wind loadings as per IS 875 part Poles shaft shall be fabricated from special steel plates, 3 mm thick, conforming to ASTM A 572 Minimum dimensions of the pole shall be bottom 135 and top 70 dia with base plate 225*225*16 mm . Poles shall be provided with base plate, section The base of the pole shall be complete in all respects with base plate before hot dip galvanising internally and externally as per ASTM A 123 and 153. Pole shall be hot dip galvanised in single dipping method. An adequate door opening shall be provided at the base of the pole at a convenient location. Provision shall be given inside this door for fixing the electrical terminals. The opening shall be such that it permits clear access to the inside of the pole. The door opening shall be complete with a close fitting, vandal resistant, door; provided with a screw type locking facility Foundation bolts for the pole shall be supplied by the pole manufacturer. Foundation bolts shall be designed and manufactured using HT steel Exposed threaded portion of the foundation bolts shall be galvanised. Bolts shall be supplied with 2 nuts and 2 washers. Complete with all required accessories like Junction box with 15A Input output connectors , 0.5 - 6 A C curve SP MCB for suitable for each light fittings 3 Core 1.5 Sq. mm Cu Flex. cable for light fitting from Junction box to Light fittings and its termination of cables should be made using with proper lugs ,Pole will Be Painted with P U Paint as per GTDC color choice .etc.

60

-

-

... More
Supply of 4 core armoured PVC/XLPE insulated, PVC sheathed aluminium conductor cable of 1.1 KV grade with ISI mark conforming to IS:1554(Part I) ,IS:7098(Part I) with latest amendments of following size. a) 4 Core 16 sq.mm

3100

-

-

... More
Supply of 3 1/2 core armoured PVC/XLPE insulated, PVC sheathed aluminium conductor cable of 1.1 KV grade with ISI mark conforming to IS:1554(Part I) ,IS:7098(Part I) with latest amendments of following size. a)3 1/2 Core 35 sq.mm

150

-

-

... More
Laying of one number PVC insulated and PVC sheathed/XLPE power cable of 1.1 KV grade of size not exceeding 25 sq.mm direct in ground including excavation in the form of a trench as per Cable Trench Drawing provided by the Engineer-Incharge,sand cushioning with screened sand bed of 20mm thick , protective covering with bricks placed breadth-wise on top of cable all over the run( the brick protection shall cover the cable and project atleast 5 cms over the sides of the cable) and backfilling the excavated earth without stones or hard material and making the surface proper with 15 cm crown on the top complete as required. a) In soily strata

2890

-

-

... More
Laying of one number PVC insulated and PVC sheathed/XLPE power cable of 1.1 KV grade of size exceeding 25 sq.mm but not exceeding 120 sq.mm direct in ground including excavation in the form of a trench as per Cable Trench Drawing provided by the Engineer-Incharge,sand cushioning with screened sand bed of 20mm thick , protective covering with bricks placed breadth-wise on top of cable all over the run( the brick protection shall cover the cable and project atleast 5 cms over the sides of the cable) and backfilling the excavated earth without stones or hard material and making the surface proper with 15 cm crown on the top complete as required. (a) In soily strata

150

-

-

... More
Laying of one number PVC insulated and PVC sheathed/XLPE power cable of 1.1 KV grade of size not exceeding 25 sq.mm in the existing RCC/HUME/STONEWARE Metal pipe, etc. complete as required

210

-

-

... More
Construction of manhole rectangular in shape including cement concrete 1:3:6 (1 cement:3 coarse sand:6 graded stone aggregate 20mm nominal size) foundation thickness of concrete 20cms and offset 10cms on both sides and first class brick work with bricks class designation 100kg/sq.cm (wire cut bricks) cement mortar 1:3 (1 cement : 3 coarse sand) 23cms thick including providing & fixing CI footrests confirming to IS 5445/69 or revised and whose weight shall not be less than 5.30kgs including fixing in man-hole at 30cm c / c in 20x 20x10cm cement concrete block 1:3:6 (1 cement :3 coarse sand : 6 graded stone aggregate 20mm nominal size) and 12mm thick plaster inside and outside with cement mortar 1:3 (1 cement : 3 coarse sand) including adding waterproofing compound of approved brand in cement mortar with a floating coat of neat cement and making channel in cement concrete 1:2:4 (1 cement :2 coarse sand : 4 graded stone aggregate 20m nominal size) neatly finished complete as per standard design. III) Inside size 0.60x0.60m and 0.60m deep (with medium duty DI manhole cover & frame of size 0.60x 0.60m weighing 90kgs ) including fixing with cement concrete 1:2:4 ( 1 cement :2 coarse sand : 4 graded stone aggregate 20mm nominal size and applying the frame & cover with coal tar.

36

-

-

... More
Providing at store or site work non-pressure RCC pipes of with collar joints conforming to IS:458-2003 revised as per amendment No.11 , including freight, carting, loading, unloading, stacking etc. complete. b) 100 mm Dia.NP2 Class

210

-

-

... More
Supplying and making cable end terminations with brass compression gland and aluminium lugs for folowing sizes of 4 Core PVC insulated PVC sheathed/XLPE aluminium conductor cable of 1.1 KV grade, complete as required. (a) 4 x 16 Sq. mm.

250

-

-

... More
Supplying and making cable end terminations with brass compression gland and aluminium lugs for folowing sizes of 3 1/2 Core PVC insulated PVC sheathed/XLPE aluminium conductor cable of 1.1 KV grade, complete as required. (a) 3 1/2 x 35 Sq. mm.

8

-

-

... More
Supply Installation, testing and commissioning of Following all Outdoor Feeder Pillar/Panels comprising below points. 1)-Panels shall be fabricated out of 16/14 swg CRCA sheet steel, with necessory structural supports in form of structural steel sections. 2)-Floor mounted, IP-55 degree protection, Bottom or Top bus duct or cable entry as per the case & Bottom cable exit steel, 2mm frame, 1.6 mm compartments & tank process treated & 2- times Epoxy painted. 3)-Proper gland size holes to be provided by the manufacturer with proper sticker and danger sign on all sides of panel. 4)-Current Density- 1.2 Ampere/1 Sq.mm (IS-8623 for factory built assembly). 5)- Earthing terminal at both end. 6)-Paint-- Exterior Enclosure Tank process treated & 1 coat of Epoxy painted and 2 coat of Siemens grey as per shade RAL7032 for exterior and Black for base frame ,everywhere maintaining micron upto 75. 7)All Starters are according to Type-II Cordination,if any . 8)Any other related details as per Engineer Incharge. Refer Single Line Diagram. 1 no. of 2 to 6 KVA 3 Phase Unbalanced fan air cooled Static voltage stabilizer with technology of DSP Based IGBT PWM Switching,Input voltage range (V L-L) =320-480 ,Output voltage (V L-L) =400 V (or 415 V),Output Voltage Regulation = 1% of nominal output voltage,Automatics High & low Voltage cut off input and out put voltage Circuit protections, single phasing preventer/Phase reversal protection,over load & Short circuit protection(Use MCB),Independent Phase Control,LCD /LED Display for regulations mode ,Bypass mode & fault conditions,Automatic bypass: A Fault conditions,Protection Class : IP 20 ,Ambient Temperature : 0 to 45 Degree Celsius ,Wave form Distortion:pure sine wave. Electronic type three phase energy meter (KWh) . (a) 5 to 20 A -1 No. Main Incomer 100 A TPN MCCB,25KA -2 Nos.,TMR 4 pole power contactor 16A to 25 A ,415V -1 No. Programmable Digital Almanac Astro Timer switch with 10 Hrs Battery Backup -1 No. Outgoing 6 A to 32 A, C series SP MCB , 10 KA-4 Nos. 6 A to 32 A, C series TP MCB , 10 KA -4 Nos. And Miscellaneous items, wire,selector switch , Cable Terminal blocks & related accessories .etc.

2

-

-

... More
Supply Installation, testing and commissioning of Following all Outdoor Feeder Pillar/Panels comprising below points. 1)-Panels shall be fabricated out of 16/14 swg CRCA sheet steel, with necessory structural supports in form of structural steel sections. 1 no. of 7 to 10 KVA 3 Phase Unbalanced fan air cooled Static voltage stabilizer with technology of DSP Based IGBT PWM Switching,Input voltage range (V L-L) =320-480 ,Output voltage (V L-L) =400 V (or 415 V),Output Voltage Regulation = 1% of nominal output voltage,Automatics High & low Voltage cut off input and out put voltage Circuit protections, single phasing preventer/Phase reversal protection,over load & Short circuit protection(Use MCB),Independent Phase Control,LCD /LED Display for regulations mode ,Bypass mode & fault conditions,Automatic bypass: A Fault conditions,Protection Class : IP 20 ,Ambient Temperature : 0 to 45 Degree Celsius ,Wave form Distortion:pure sine wave. 2)-Floor mounted, IP-55 degree protection, Bottom or Top bus duct or cable entry as per the case & Bottom cable exit steel, 2mm frame, 1.6 mm compartments & tank process treated & 2- times Epoxy painted. 3)-Proper gland size holes to be provided by the manufacturer with proper sticker and danger sign on all sides of panel. 4)-Current Density- 1.2 Ampere/1 Sq.mm (IS-8623 for factory built assembly). 5)- Earthing terminal at both end. 6)-Paint-- Exterior Enclosure Tank process treated & 1 coat of Epoxy painted and 2 coat of Siemens grey as per shade RAL7032 for exterior and Black for base frame ,everywhere maintaining micron upto 75. 7)All Starters are according to Type-II Cordination, if any . 8)Any other related details as per Engineer Incharge. Refer Single Line Diagram. 1 no. of 7 to 10 KVA 3 Phase Unbalanced fan air cooled Static voltage stabilizer with technology of DSP Based IGBT PWM Switching,Input voltage range (V L-L) =320-480 ,Output voltage (V L-L) =400 V (or 415 V),Output Voltage Regulation = 1% of nominal output voltage,Automatics High & low Voltage cut off input and out put voltage Circuit protections, single phasing preventer/Phase reversal protection,over load & Short circuit protection(Use MCB),Independent Phase Control,LCD /LED Display for regulations mode ,Bypass mode & fault conditions,Automatic bypass: A Fault conditions,Protection Class : IP 20 ,Ambient Temperature : 0 to 45 Degree Celsius ,Wave form Distortion:pure sine wave. Electronic type three phase energy meter (KWh) . (a) 5 to 20 A -1 No. Main Incomer 100 A TPN MCCB,25KA -2 Nos.,TMR 4 pole power contactor 16A to 25 A ,415V -1 No. Programmable Digital Almanac Astro Timer switch with 10 Hrs Battery Backup -1 No. Outgoing 6 A to 32 A, C series SP MCB , 10 KA-4 Nos.6 A to 32 A, C series TP MCB , 10 KA -4 Nos.And Miscellaneous items, wire,selector switch , Cable Terminal blocks & related accessories .etc.

2

-

-

... More
Earthing with GI earth pipe 2 mts long 40 mm dia medium class with ISI mark, of approved brands including accessories and providing masonry enclosure with CI/RCC cover having locking /Lifting arrangement and watering pipe etc. (but without charcoal or coke and salt) as required as per the Earthing Drawing provided by the Engineer-Incharge.The scope of work includes the following: a) Excavation of pit of size not less than 1.0x1.0x 2.0 mtrs(min) and disposal of excavated soil. b) Class B GI pipe, 40mm diameter as per specifications. c) Charcoal/salt as per specs ( paid seperately). d) Refilling the pit of size not less than 1.0x1.0x 2.0 mtrs(min) with soft black soil of minimum resistivity i/c transportation. e)Masonary chamber with proper foundation, cover plate and locking arrangement. f) Testing of earth value with earth megger and certifications of its value. Aluminium tag with embossed earthing value to be attached to the pipe . g)watering arrangement(plumbing will be paid seperately).(b) In rocky strata

25

-

-

... More
Earthing with GI earth plate 600 mm x 600 mm x 6 mm thick including accessories and providing masonry enclosure with CI/RCC cover having locking/Lifting arrangement and watering pipe etc. (but without charcoal or coke and salt) as required as per the Earthing Drawing provided by the Engineer-Incharge.The scope of work includes the following: a) Excavation of pit of size 1.0x1.0x 3.0 mtrs(min) and disposal of excavated soil. c)Watering GI pipe, 20mm, Class B, with funnel as per specs. d) Charcoal/salt as per specs ( paid seperately). e) Refilling the pit of size 1.0x1.0x 3.0 mtrs(min) with soft black agriculture soil of minimum resistivity i/c transportation. e)Masonary chamber with proper foundation, cover plate and locking arrangement. f) Testing of earth value with earth megger and certifications of its value. Aluminium tag with embossed earthing value to be attached to the pipe.g)watering arrangement(plumbing will be paid seperately). b)In rocky strata

8

-

-

... More
Extra for using salt and charcoal for pipe earth electrode as required( 65 Kgs of Charcoal and 5 Kgs of Salt).

33

-

-

... More
Supplying and laying 25 mm x 6 mm GI strip at 0.5 m below ground as strip earth electrode including soldering etc. as required

80

-

-

... More
Supplying and laying 6 SWG GI wire at 0.5 m below ground level for conductor earth electrode including soldering etc. as required

3250

-

-



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.