Goa Tourism Development Corporation Limited Tender

View complete overview of Goa GTDC Tender

Goa Tourism Development Corporation Limited - GTDC Tender

Works
Electrical Generators And Transformers
Electrical and Electronics
Eprocure
Opening Date24 May 2023
Closing Date8 Jun 2023
Tender AmountRefer Documents 
Notes
Download

Costs

  • EMD

    ₹ 1,87,112
  • Document Cost

    ₹ 6,500
  • Tender Fee

    ₹ 6,000

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
Supply and providing Chemical earthing system (Pipe in pipe type) with Outer pipe of the electrode having minimum 80mm diameter as per the enclosed specifiations and drawing.The outer and the inner hot dip galvanised MS pipes shall conform to the specifications and the space inbetween shall be filled with highly crystalline conductive and anti- corrosive mixture conforming to IS-3043. The earth electrode shall be CPRI tested.The scope of work includes boring( 300mm dia mimnimum)/exvavation of soil/hard rock, refilling with required quantity of back fill compound/Ground resistance enhancement powder of requisite quantity, compaction, constuction of masonary chamber etc complete as required to obtain the desired value.Aluminium tag with embossed earthing value shall be permanently attached to the pipe electrode 2 metres length electrode

8

-

-

... More
Supply of Back fill Compound/ Groung resistance enhancement powder conforming to the standard specifications.

4

-

-

... More
Providing and laying GI tape 32 mm x 6 mm from earth electrode directly in ground as required

15

-

-

... More
Supply of 3 1/2 core armoured PVC/XLPE insulated, PVC sheathed aluminium conductor cable of 1.1 KV grade with ISI mark conforming to IS:1554(Part I) ,IS:7098(Part I) with latest amendments of following size. 3 1/2 Core 50 sq.mm

94

-

-

... More
Supply of 3 1/2 core armoured PVC/XLPE insulated, PVC sheathed aluminium conductor cable of 1.1 KV grade with ISI mark conforming to IS:1554(Part I) ,IS:7098(Part I) with latest amendments of following size. 3 1/2 Core 120 sq.mm

47

-

-

... More
Supply of 3 1/2 core armoured PVC/XLPE insulated, PVC sheathed aluminium conductor cable of 1.1 KV grade with ISI mark conforming to IS:1554(Part I) ,IS:7098(Part I) with latest amendments of following size. 3 1/2 Core 300 sq.mm

61

-

-

... More
Supply of 4 core armoured PVC/XLPE insulated, PVC sheathed aluminium conductor cable of 1.1 KV grade with ISI mark conforming to IS:1554(Part I) ,IS:7098(Part I) with latest amendments of following size. 4 Core 16 sq.mm

52

-

-

... More
Supply of 4 core armoured PVC/XLPE insulated, PVC sheathed aluminium conductor cable of 1.1 KV grade with ISI mark conforming to IS:1554(Part I) ,IS:7098(Part I) with latest amendments of following size. 4 Core 25 sq.mm

10

-

-

... More
Supply of following size of 3 core, HV, 11 KV grade, ISI mark, XLPE cable with stranded compact circular aluminium conductor, conductor screened with extruded semiconducting compound, XLPE insulated, insulation screned with extruded semiconducting compound in combination with copper tape(0.3 KA for 1Sec.) cores laid off,inner sheath of PVC tape,galvanised steel flat strip armoured and overall PVC sheathed cable conforming to IS:7098(Part II) with latest amendments. 3 Core 120 sq.mm

42

-

-

... More
Supply of following size of 3 core, HV, 11 KV grade, ISI mark, XLPE cable with stranded compact circular aluminium conductor, conductor screened with extruded semiconducting compound, XLPE insulated, insulation screned with extruded semiconducting compound in combination with copper tape(0.3 KA for 1Sec.) cores laid off,inner sheath of PVC tape,galvanised steel flat strip armoured and overall PVC sheathed cable conforming to IS:7098(Part II) with latest amendments. 3 Core 300 sq.mm

62

-

-

... More
Laying of one number PVC insulated and PVC sheathed/XLPE power cable of 1.1 KV grade of size not exceeding 25 sq.mm direct in ground including excavation in the form of a trench as per Cable Trench Drawing provided by the Engineer-Incharge,sand cushioning with screened sand bed of 20mm thick , protective covering with bricks placed breadth-wise on top of cable all over the run( the brick protection shall cover the cable and project atleast 5 cms over the sides of the cable) and backfilling the excavated earth without stones or hard material and making the surface proper with 15 cm crown on the top complete as required. In soily strata

37

-

-

... More
Laying of one number PVC insulated and PVC sheathed/XLPE power cable of 1.1 KV grade of size exceeding 25 sq.mm but not exceeding 120 sq.mm direct in ground including excavation in the form of a trench as per Cable Trench Drawing provided by the Engineer-Incharge,sand cushioning with screened sand bed of 20mm thick , protective covering with bricks placed breadth-wise on top of cable all over the run( the brick protection shall cover the cable and project atleast 5 cms over the sides of the cable) and backfilling the excavated earth without stones or hard material and making the surface proper with 15 cm crown on the top complete as required. In soily strata

37

-

-

... More
Laying of one number PVC insulated and PVC sheathed/XLPE power cable of 1.1 KV grade of size exceeding 120 sq.mm but not exceeding 400 sq.mm direct in ground including excavation in the form of a trench as per Cable Trench Drawing provided by the Engineer-Incharge,sand cushioning with screened sand bed of 20mm thick , protective covering with bricks placed breadth-wise on top of cable all over the run( the brick protection shall cover the cable and project atleast 5 cms over the sides of the cable)and backfilling the excavated earth without stones or hard material and making the surface proper with 15 cm crown on the top complete as required. In soily strata

35

-

-

... More
Laying of one number additional PVC insulated and PVC sheathed/XLPE power cable of 1.1 KV grade of size not exceeding 25 sq.mm direct in ground in the same trench in one tier horizontal formation including excavation in the form of a trench as per Cable Trench Drawing provided by the Engineer-Incharge,sand cushioning with screened sand bed of 20mm thick , protective covering with bricks placed breadth-wise on top of cable all over the run( the brick protection shall cover the cable and project atleast 5 cms over the sides of the cable) and backfilling the excavated earth without stones or hard material and making the surface proper with 15 cm crown on the top complete as required. In soily strata

5

-

-

... More
Laying of one number additional PVC insulated and PVC sheathed/XLPE power cable of 1.1 KV grade of size exceeding 25 sq.mm but not exceeding 120 sq.mm direct in ground in the same trench in one tier horizontal formaion including excavation in the form of a trench as per Cable Trench Drawing provided by the Engineer-Incharge,sand cushioning with screened sand bed of 20mm thick , protective covering with bricks placed breadth-wise on top of cable all over the run( the brick protection shall cover the cable and project atleast 5 cms over the sides of the cable) and backfilling the excavated earth without stones or hard material and making the surface proper with 15 cm crown on the top complete as required. In soily strata

43

-

-

... More
Laying of one number PVC insulated and PVC sheathed/XLPE power cable of 1.1 KV grade of size not exceeding 25 sq.mm in the existing RCC/HUME/STONEWARE Metal pipe, etc. complete as required

5

-

-

... More
Laying of one number PVC insulated and PVC sheathed/XLPE power cable of 1.1 KV grade of size exceeding 25 sq.mm but not exceeding 400 sq.mm in the existing RCC/HUME/STONEWARE Metal pipe, etc. complete as required

11

-

-

... More
Laying of one number PVC insulated and PVC sheathed/XLPE power cable of 1.1 KV grade of size not exceeding 25 sq.mm on surface, etc. complete as required

14

-

-

... More
Laying of one number PVC insulated and PVC sheathed/XLPE power cable of 1.1 KV grade of size exceeding 25 sq.mm but not exceeding 120 sq.mm on surface, etc. complete as required

49

-

-

... More
Laying of one number PVC insulated and PVC sheathed/XLPE power cable of 1.1 KV grade of size exceeding 120 sq.mm but not exceeding 400 sq.mm on surface, etc. complete as required

26

-

-

... More
Laying of one number PVC insulated and PVC sheathed/XLPE power cable of grade exceeding 1.1 KV but not exceeding 11 KV grade of size not exceeding 120 sq.mm direct in ground including excavation in the form of a trench as per Cable Trench Drawing provided by the Engineer-Incharge,sand cushioning with screened sand bed of 20mm thick , protective covering with bricks placed lenghtwise on top of cable all over the run and backfilling the excavated earth without stones or hard material and making the surface proper with 15 cm crown on the top complete as required. Soily strata

25

-

-

... More
Laying of one number PVC insulated and PVC sheathed/XLPE power cable of grade exceeding 1.1 KV but not exceeding 11 KV grade of size exceeding 120 sq.mm but not exceeding 400 sq.mm direct in ground including excavation in the form of a trench as per Cable Trench Drawing provided by the Engineer-Incharge,sand cushioning with screened sand bed of 20mm thick , protective covering with bricks placed lenghtwise on top of cable all over the run and backfilling the excavated earth without stones or hard material and making the surface proper with 15 cm crown on the top complete as required. Soily strata

34

-

-

... More
Supplying and making cable end terminations with brass compression gland and aluminium lugs for folowing sizes of 3 1/2 Core PVC insulated PVC sheathed/XLPE aluminium conductor cable of 1.1 KV grade, complete as required. 3 1/2 x 50 Sq. mm.

6

-

-

... More
Supplying and making cable end terminations with brass compression gland and aluminium lugs for folowing sizes of 3 1/2 Core PVC insulated PVC sheathed/XLPE aluminium conductor cable of 1.1 KV grade, complete as required. 3 1/2 x 120 Sq. mm.

4

-

-

... More
Supplying and making cable end terminations with brass compression gland and aluminium lugs for folowing sizes of 3 1/2 Core PVC insulated PVC sheathed/XLPE aluminium conductor cable of 1.1 KV grade, complete as required. 3 1/2 x 300 Sq. mm.

4

-

-

... More
Supplying and making cable end terminations with brass compression gland and aluminium lugs for folowing sizes of 4 Core PVC insulated PVC sheathed/XLPE aluminium conductor cable of 1.1 KV grade, complete as required. 4 x 16 Sq. mm.

4

-

-

... More
Supplying and making cable end terminations with brass compression gland and aluminium lugs for folowing sizes of 4 Core PVC insulated PVC sheathed/XLPE aluminium conductor cable of 1.1 KV grade, complete as required. 4 x 25 Sq. mm.

4

-

-

... More
Supplying and making Indoor cable end termination with heat shrinkable kit for following sizes of PVC insulated PVC sheathed/XLPE aluminium conductor cable upto 11 KV grade, complete as required. 11 KV, 3 Core x 120 - 185 sq.mm

8

-

-

... More
Supplying and making Indoor cable end termination with heat shrinkable kit for following sizes of PVC insulated PVC sheathed/XLPE aluminium conductor cable upto 11 KV grade, complete as required. 11 KV, 3 Core x 240 - 300sq.mm

2

-

-

... More
Supplying and making Outdoor cable end termination with heat shrinkable kit for following sizes of PVC insulated PVC sheathed/XLPE aluminium conductor cable upto 11 KV grade, complete as required. 11 KV, 3 Core x 120 - 185 sq.mm

4

-

-

... More
Supplying and making Outdoor cable end termination with heat shrinkable kit for following sizes of PVC insulated PVC sheathed/XLPE aluminium conductor cable upto 11 KV grade, complete as required. 11 KV, 3 Core x 240 - 300sq.mm

2

-

-

... More
Supply , Erection ,Testing & commissioning of 11 KV Metering cubicle having 3 Nos of P.T's and 3 Nos of C.T's having ratio ,class of accuracy and burden as required for the load.The C.T 's , P.T's , metering cubicle should be MRT tested and as per the Design and approval of MRT Div - VII, Margao. Metering cubicle should be provided with a DLMS protocol adhering Trivector meter which is tested by MRT.The CTPT metering cubicle should be provided with the necessary concrete foundation mountable structure.One metering cubicle will be for the GED metering and the other metering cubicle will be client side checkmetering cubicle.The necessary SCADA compatible accessories are also to be provided. The Cubicle should have 7 sealing arrangements as per MRT guidelines. Job includes civil works of making foundation.

2

-

-

... More
Supply, Erection, testing & commissioning of 11KV, 3 phase, Straight through joint kit , heat shrinkable kit complete, for 11 KV XLPE cable of size 3 x 150 - 300sq.mm including sockets/lugs/connectors etc. Make : 3 M/ Raychem.

2

-

-

... More
supply, laying and fixing with collar heavy duty non-pressure class RCC pipe with cement mortar in proportion 1:2m jointing materials etc. complete with 250 mm2 dia

38

-

-

... More
Supply and erection of HDG earthing strip with proper welding wherever required and painting with red oxide paint at the portion of welding, drilling cutting etc.for connecting earthing pipe and other equipments of size 50 x 6 mm

145

-

-

... More
Supply, Erection, testing & commissioning of 11KV, 630 Amps, Outdoor, motorised /non motorised SF6 Ring Main Unit with two Load Break Switches and one Circuit Breaker or with two Load Break Switches and two Circuit Breaker conforming to International Standards and complete with Fault Passage Indicator other accessories as required for Scada requirements of Goa electricity department & of approved make of Goa electricity department. Make: CG-Lucy /Siemens.

1

-

-

... More
Supply, Erection, testing & commissioning of 11KV, 630 Amps, Outdoor, motorised ,non motorised ,extensible SF6 Ring Main Unit with One Siwtch and one Circuit Breaker conforming to International Standards and complete with Fault Passage Indicator other accessories as required for Scada requirements of Goa electricity department & of approved make of Goa electricity department. Make: CG-Lucy /Siemens.

1

-

-

... More
Supply, Erection, testing & commissioning of 11KV, 400 Amps, Outdoor, oil switch fuse unit /Breaker conforming to International Standards and complete with Fault Passage Indicator other accessories as required for Scada requirements of Goa electricity department & of approved make of Goa electricity department.First fill of oil to be included. Make: Lucy .

2

-

-

... More
Supplying and Laying of Sand (river) etc as required

15

-

-

... More
Kaddapa of size 600mm length x 250mm width x 37mm thick as a protective cover for underground cables

300

-

-

... More
Supply & erection of 11 Kv /433 v 250 KVA distribution transformers loss level II(Copper /Al wound) With On Load Tap Changer/Off load tap changer complete with all necessary standard fittings, outdoor type with HV - Cable Box & LV Cable Box with First Filling of Oil, as per IS 1180 (Part-I_2014).Make: Voltamp /Crompton / Bharat Bijlee /equivalent . Transformer specification as follows: Rating: 250KVA No load Voltage Ratio: 11/0.433 KV Quantity: 1 No. Application: Distribution Transformer Vector Group: Dyn11(HV - Delta; LV - Star) Temperature rise (Oil / Wdg): 40/45ºC (Amb. 50ºC) Cooling: ONAN [ Oil Natural Air Natural] Type of Tap changer: On Load Tap Changer Off Circuit Tap Changer "Tapping range: +5% to -15% @ 1.25% on HV" Impedance at 75° C: 4.5 % (Sub. To IS Tol.) Total Losses at 50% Loading: As per 1180 level 2 Total Losses at 100% Loading: As per 1180 level 2 Termination- HV / LV: HV : Cable Box / LV : Cable Box Orientation between HV & LV: 180° Installation: Outdoor Reference Standards: IS : 1180 [Energy Efficiency Level II] Make: Voltamp /Crompton / Bharat Bijlee /equivalent

1

-

-

... More
Supply & Installation of LT 250 KVA On-Load, Linear roller type Automatic Voltage Regulator. GLobe / GLOBAL / Servokon make or equivalent, Rolling Contact type AUTOMATIC VOLTAGE REGULATOR with following data : INPUT VOLTAGE : 340 Volts to 460 Volts, 3-Ph, 50 Hz A.C. OUTPUT VOLTAGE : 415 Volts ± 1 %, 3-Ph, 50 Hz A.C. CAPACITY : 250 KVA DUTY CYCLE : 100 % Continuous COOLING : ONAN (With first filling of Trf. Oil)

1

-

-

... More
Supply design and installation of LT panel comprising of Main Incomer MCCB 400Amps with 400Amps bypass switch .Panel shouldbe designedforoutdoor standalone application.The panel should comprise all accessories so as to allow the bypass of the AVR in case failure.Necessary electrical interlock is to be provided.Makeof swictgear: Socomec /Schneider /equivalent.

1

-

-

... More
Supply design and installation of LT panel as suitable for load 150 KVA to 400 KVA having Incomer isolation /protection ACB /MCCB , Automatic changer over arrangement with ATS ,outgoing feeder MCCBs / MCB's , indication Lamps LT panel, CT's ,PTs',Capacitor bank of 60 KVAr - 200 KVAr APFCR panel , thyristor and haronics resistant in between the transformer and AVR along with byepass switch.Switchgear Make: Schneider /L&T/Siemens /equivalent .BMS to be incorporated ,microprocessor system

1

-

-

... More
Supply, Erection, testing & commissioning of 11KV, 3 phase, Straight through joint kit , heat shrinkable kit complete, for 11 KV XLPE cable of size 3 x 25 sq.mm - 150sq.mm including sockets/lugs/connectors etc. Make : 3 M/ Raychem.

15

-

-

... More
Supply, Erection, testing & commissioning of 11KV, 3 phase, Straight through joint kit , heat shrinkable kit complete, for 11 KV XLPE cable of size 3 x 150 sq.mm - 300sq.mm including sockets/lugs/connectors etc. Make : 3 M/ Raychem.

14

-

-

... More
Reinstatment of roads ,concrete, pavers ,tiles after laying the cables etc as required.

10

-

-

... More
Supply and installation of fire safety buckte with sand etc as required

4

-

-

... More
supply and instalaltion of fire extinguisher CO2 type with base 4 Kg or more cylinder along with holder on wall surface etc as required.

2

-

-

... More
supply and fixing first aid kits etc as required.

2

-

-

... More
supply and laying shock proof rubber mat of size 2 mtrs x 1 mtr x 2mm etc as required

2

-

-

... More
supply and fixing fire bucket stands suitable for installaltion of two or more fire safety buckets etc as required

1

-

-

... More
Job of disconnecting existing main panel in the panel room , the meter panel, outgoing distribution panels, DG supply , changeover supply , disconnecting its Cables ,disconnecting of glandings , removing and refitting of cable trays.Job also includes the critical job of providing temporary supply and restoring the Hotel supply at the time of erecting new panels in the same panel room with all safety measures etc as required.

1

-

-

... More
Preparation of all drawings /slds/ Files for Govt Department for obtaining necessary approvel from RIO Electricity department, MRT margao etc. for of the scheme and releasing connection including submission of all documents by obtaining signature from from concerned authoriries in drawings and files and submission of necessary test report and other documents to RIO and Electricity Department

1

-

-

... More
Supply ,erection ,testing & Commissioning of Cable route Marker

20

-

-

... More
Supply ,erection ,testing & Commissioning of Modem compatible to the latest scada protocol of Goa electricity department.

2

-

-

... More
Supply ,erection ,testing & Commissioning of DLMS protocol meter

2

-

-

... More
Supply ,Erection ,Testing Commissioning of HDGI rung bolted ladder type /perforated trays of size 100 x 50 x 2 mm upto 600 x 50 x 2 mm with all its necessary hardwares and bends and couplers.Make: Profab / Equivalent.

10

-

-

... More
Supply and installing of structural GI material such as angles, channels ,nut ,bolts ,etc

45

-

-

... More
Supply design and installation of LT panel as suitable for load 50 KVA to 100 KVA having Incomer isolation /protection ACB /MCCB , Automatic changer over arrangement with ATS ,outgoing feeder MCCBs / MCB's , indication Lamps LT panel, CT's ,PTs', thyristor and haronics resistant in between the Main panel and the entrance of restaurant ..Switchgear Make: Schneider /L&T/Siemens /equivalent .BMS to be incorporated ,microprocessor system

1

-

-

... More
Providing of fencing for the sub station yard ,fencing will be provided with MS angles duly painted of 50 x 50 x 5 mm at , angles , falts and chain link mesh. The fencing will be provided with 2 mts wide entrance door.Fencing height will be 2 mts .

30

-

-

... More
Supply and laying of 40mm Khadi (trap metal) etc as required.

6

-

-

... More
Supply and erection of enamelled danger board of 11 KV.

8

-

-

... More
Earthwork in excavation by mechanical means (hydraulic excavator)/manual means in foundation pipeline trenches drain (not exceeding 1.5 m in width or 10 sq.m. on plan) including dressing of sides and ramming of bottoms, lift upto 1.5 m including getting out the excavated soil and disposal of surplus excavated soil as directed within a lead of 50 m. All kinds of soil

20

-

-

... More
Refilling the pipeline/foundation trenches plinth sides, foundation etc. with available excavated earth in layers not exceeding 20 cm depth consolidating each layer ramming and watering lead upto 50 M and all lifts and disposal of surplus earth as directed by Engineer in Charge.

18

-

-

... More
Rubble packing with hard laterite stone under floors including watering ramming and consolidating etc. in pipeline trenches and other foundations complete.

15

-

-

... More
Laterite masonry in neatly dressed stones of size as specified in cement mortar 1: 4 (1 cement : 4 coarse sand) in foundation and basement.

3

-

-

... More
Providing and laying in position cement concrete 1:2:4 (1 cement : 2 coarse sand: 4 graded granitic or basaltic stone aggregate 40 m nominal size) excluding cost of centering, shuttering and finishing : All works upto plinth level

5

-

-

... More
Centering & shuttering including Strutting, Propping & removal of forms for : Foundations, Footings, Bases for columns

10

-

-

... More
12mm cement plaster 1:3 (1 cement : 3 fine sand)

11

-

-

... More
Demolishing cement concrete 1:3:6 or richer mix including disposal of material within 50 m lead.

7

-

-



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.