Goa Tourism Development Corporation Limited Tender
View complete overview of Goa GTDC Tender
Costs
EMD
₹ 1,87,112Document Cost
₹ 6,500Tender Fee
₹ 6,000
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2023_GTDCL_8933_1Bid Award Id
ViewTender No
No 1-1/712/2022-GT/ENGG/957Tender Authority
Goa Tourism Development Corporation Limited ViewPurchaser Address
-Website
http://eprocure.goa.gov.in
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
BOQ Items
Supply and providing Chemical earthing system (Pipe in pipe type) with Outer pipe of the electrode having minimum 80mm diameter as per the enclosed specifiations and drawing.The outer and the inner hot dip galvanised MS pipes shall conform to the specifications and the space inbetween shall be filled with highly crystalline conductive and anti- corrosive mixture conforming to IS-3043. The earth electrode shall be CPRI tested.The scope of work includes boring( 300mm dia mimnimum)/exvavation of soil/hard rock, refilling with required quantity of back fill compound/Ground resistance enhancement powder of requisite quantity, compaction, constuction of masonary chamber etc complete as required to obtain the desired value.Aluminium tag with embossed earthing value shall be permanently attached to the pipe electrode 2 metres length electrode
8
-
-
Supply of Back fill Compound/ Groung resistance enhancement powder conforming to the standard specifications.
4
-
-
Providing and laying GI tape 32 mm x 6 mm from earth electrode directly in ground as required
15
-
-
Supply of 3 1/2 core armoured PVC/XLPE insulated, PVC sheathed aluminium conductor cable of 1.1 KV grade with ISI mark conforming to IS:1554(Part I)
,IS:7098(Part I) with latest amendments of following size. 3 1/2 Core 50 sq.mm
94
-
-
Supply of 3 1/2 core armoured PVC/XLPE insulated, PVC sheathed aluminium conductor cable of 1.1 KV grade with ISI mark conforming to IS:1554(Part I)
,IS:7098(Part I) with latest amendments of following size. 3 1/2 Core 120 sq.mm
47
-
-
Supply of 3 1/2 core armoured PVC/XLPE insulated, PVC sheathed aluminium conductor cable of 1.1 KV grade with ISI mark conforming to IS:1554(Part I)
,IS:7098(Part I) with latest amendments of following size. 3 1/2 Core 300 sq.mm
61
-
-
Supply of 4 core armoured PVC/XLPE insulated, PVC sheathed aluminium conductor cable of 1.1 KV grade with ISI mark conforming to IS:1554(Part I)
,IS:7098(Part I) with latest amendments of following size. 4 Core 16 sq.mm
52
-
-
Supply of 4 core armoured PVC/XLPE insulated, PVC sheathed aluminium conductor cable of 1.1 KV grade with ISI mark conforming to IS:1554(Part I)
,IS:7098(Part I) with latest amendments of following size. 4 Core 25 sq.mm
10
-
-
Supply of following size of 3 core, HV, 11 KV grade, ISI mark, XLPE cable with stranded compact circular aluminium conductor, conductor screened with extruded semiconducting compound, XLPE insulated, insulation screned with extruded semiconducting compound in combination with copper tape(0.3 KA for 1Sec.) cores laid off,inner sheath of PVC tape,galvanised steel flat strip armoured and overall PVC sheathed cable conforming to IS:7098(Part II) with latest amendments. 3 Core 120 sq.mm
42
-
-
Supply of following size of 3 core, HV, 11 KV grade, ISI mark, XLPE cable with stranded compact circular aluminium conductor, conductor screened with extruded semiconducting compound, XLPE insulated, insulation screned with extruded semiconducting compound in combination with copper tape(0.3 KA for 1Sec.) cores laid off,inner sheath of PVC tape,galvanised steel flat strip armoured and overall PVC sheathed cable conforming to IS:7098(Part II) with latest amendments. 3 Core 300 sq.mm
62
-
-
Laying of one number PVC insulated and PVC sheathed/XLPE power cable of 1.1 KV grade of size not exceeding 25 sq.mm direct in ground including excavation in the form of a trench as per Cable Trench Drawing provided by the Engineer-Incharge,sand cushioning with screened sand bed of 20mm thick , protective covering with bricks placed breadth-wise on top of cable all over the run( the brick protection shall cover the cable and project atleast 5 cms over the sides of the cable) and backfilling the excavated earth without stones or hard material and making the surface proper with 15 cm crown on the top complete as required. In soily strata
37
-
-
Laying of one number PVC insulated and PVC sheathed/XLPE power cable of 1.1 KV grade of size exceeding 25 sq.mm but not exceeding 120 sq.mm direct in ground including excavation in the form of a trench as per Cable Trench Drawing provided by the Engineer-Incharge,sand cushioning with screened sand bed of 20mm thick , protective covering with bricks placed breadth-wise on top of cable all over the run( the brick protection shall cover the cable and project atleast 5 cms over the sides of the cable) and backfilling the excavated earth without stones or hard material and making the surface proper with 15 cm crown on the top complete as required. In soily strata
37
-
-
Laying of one number PVC insulated and PVC sheathed/XLPE power cable of 1.1 KV grade of size exceeding 120 sq.mm but not exceeding 400 sq.mm direct in ground including excavation in the form of a trench as per Cable Trench Drawing provided by the Engineer-Incharge,sand cushioning with screened sand bed of 20mm thick , protective covering with bricks placed breadth-wise on top of cable all over the run( the brick protection shall cover the cable and project atleast 5 cms over the sides of the cable)and backfilling the excavated earth without stones or hard material and making the surface proper with 15 cm crown on the top complete as required. In soily strata
35
-
-
Laying of one number additional PVC insulated and PVC sheathed/XLPE power cable of 1.1 KV grade of size not exceeding 25 sq.mm direct in ground in the same trench in one tier horizontal formation including excavation in the form of a trench as per Cable Trench Drawing provided by the Engineer-Incharge,sand cushioning with screened sand bed of 20mm thick , protective covering with bricks placed breadth-wise on top of cable all over the run( the brick protection shall cover the cable and project atleast 5 cms over the sides of the cable) and backfilling the excavated earth without stones or hard material and making the surface proper with 15 cm crown on the top complete as required. In soily strata
5
-
-
Laying of one number additional PVC insulated and PVC sheathed/XLPE power cable of 1.1 KV grade of size exceeding 25 sq.mm but not exceeding 120 sq.mm direct in ground in the same trench in one tier horizontal formaion including excavation in the form of a trench as per Cable Trench Drawing provided by the Engineer-Incharge,sand cushioning with screened sand bed of 20mm thick , protective covering with bricks placed breadth-wise on top of cable all over the run( the brick protection shall cover the cable and project atleast 5 cms over the sides of the cable) and backfilling the excavated earth without stones or hard material and making the surface proper with 15 cm crown on the top complete as required. In soily strata
43
-
-
Laying of one number PVC insulated and PVC sheathed/XLPE power cable of 1.1 KV grade of size not exceeding 25 sq.mm in the existing RCC/HUME/STONEWARE Metal pipe, etc. complete as required
5
-
-
Laying of one number PVC insulated and PVC sheathed/XLPE power cable of 1.1 KV grade of size exceeding 25 sq.mm but not exceeding 400 sq.mm in the existing RCC/HUME/STONEWARE Metal pipe, etc. complete as required
11
-
-
Laying of one number PVC insulated and PVC sheathed/XLPE power cable of 1.1 KV grade of size not exceeding 25 sq.mm on surface, etc. complete as required
14
-
-
Laying of one number PVC insulated and PVC sheathed/XLPE power cable of 1.1 KV grade of size exceeding 25 sq.mm but not exceeding 120 sq.mm on surface, etc. complete as required
49
-
-
Laying of one number PVC insulated and PVC sheathed/XLPE power cable of 1.1 KV grade of size exceeding 120 sq.mm but not exceeding 400 sq.mm on surface, etc. complete as required
26
-
-
Laying of one number PVC insulated and PVC sheathed/XLPE power cable of grade exceeding 1.1 KV but not exceeding 11 KV grade of size not exceeding 120 sq.mm direct in ground including excavation in the form of a trench as per Cable Trench Drawing provided by the Engineer-Incharge,sand cushioning with screened sand bed of 20mm thick , protective covering with bricks placed lenghtwise on top of cable all over the run and backfilling the excavated earth without stones or hard material and making the surface proper with 15 cm crown on the top complete as required. Soily strata
25
-
-
Laying of one number PVC insulated and PVC sheathed/XLPE power cable of grade exceeding 1.1 KV but not exceeding 11 KV grade of size exceeding 120 sq.mm but not exceeding 400 sq.mm direct in ground including excavation in the form of a trench as per Cable Trench Drawing provided by the Engineer-Incharge,sand cushioning with screened sand bed of 20mm thick , protective covering with bricks placed lenghtwise on top of cable all over the run and backfilling the excavated earth without stones or hard material and making the surface proper with 15 cm crown on the top complete as required. Soily strata
34
-
-
Supplying and making cable end terminations with brass compression gland and aluminium lugs for folowing sizes of 3 1/2 Core PVC insulated PVC sheathed/XLPE aluminium conductor cable of 1.1 KV grade, complete as required. 3 1/2 x 50 Sq. mm.
6
-
-
Supplying and making cable end terminations with brass compression gland and aluminium lugs for folowing sizes of 3 1/2 Core PVC insulated PVC sheathed/XLPE aluminium conductor cable of 1.1 KV grade, complete as required. 3 1/2 x 120 Sq. mm.
4
-
-
Supplying and making cable end terminations with brass compression gland and aluminium lugs for folowing sizes of 3 1/2 Core PVC insulated PVC sheathed/XLPE aluminium conductor cable of 1.1 KV grade, complete as required. 3 1/2 x 300 Sq. mm.
4
-
-
Supplying and making cable end terminations with brass compression gland and aluminium lugs for folowing sizes of 4 Core PVC insulated PVC sheathed/XLPE aluminium conductor cable of 1.1 KV grade, complete as required. 4 x 16 Sq. mm.
4
-
-
Supplying and making cable end terminations with brass compression gland and aluminium lugs for folowing sizes of 4 Core PVC insulated PVC sheathed/XLPE aluminium conductor cable of 1.1 KV grade, complete as required. 4 x 25 Sq. mm.
4
-
-
Supplying and making Indoor cable end termination with heat shrinkable kit for following sizes of PVC insulated PVC sheathed/XLPE aluminium conductor cable upto 11 KV grade, complete as required. 11 KV, 3 Core x 120 - 185 sq.mm
8
-
-
Supplying and making Indoor cable end termination with heat shrinkable kit for following sizes of PVC insulated PVC sheathed/XLPE aluminium conductor cable upto 11 KV grade, complete as required. 11 KV, 3 Core x 240 - 300sq.mm
2
-
-
Supplying and making Outdoor cable end termination with heat shrinkable kit for following sizes of PVC insulated PVC sheathed/XLPE aluminium conductor cable upto 11 KV grade, complete as required. 11 KV, 3 Core x 120 - 185 sq.mm
4
-
-
Supplying and making Outdoor cable end termination with heat shrinkable kit for following sizes of PVC insulated PVC sheathed/XLPE aluminium conductor cable upto 11 KV grade, complete as required. 11 KV, 3 Core x 240 - 300sq.mm
2
-
-
Supply , Erection ,Testing & commissioning of 11 KV Metering cubicle having 3 Nos of P.T's and 3 Nos of C.T's having ratio ,class of accuracy and burden as required for the load.The C.T 's , P.T's , metering cubicle should be MRT tested and as per the Design and approval of MRT Div - VII, Margao. Metering cubicle should be provided with a DLMS protocol adhering Trivector meter which is tested by MRT.The CTPT metering cubicle should be provided with the necessary concrete foundation mountable structure.One metering cubicle will be for the GED metering and the other metering cubicle will be client side checkmetering cubicle.The necessary SCADA compatible accessories are also to be provided. The Cubicle should have 7 sealing arrangements as per MRT guidelines. Job includes civil works of making foundation.
2
-
-
Supply, Erection, testing & commissioning of 11KV, 3 phase, Straight through joint kit , heat shrinkable kit complete, for 11 KV XLPE cable of size 3 x 150 - 300sq.mm including sockets/lugs/connectors etc. Make : 3 M/ Raychem.
2
-
-
supply, laying and fixing with collar heavy duty non-pressure class RCC pipe with cement mortar in proportion 1:2m jointing materials etc. complete with 250 mm2 dia
38
-
-
Supply and erection of HDG earthing strip with proper welding wherever required and painting with red oxide paint at the portion of welding, drilling cutting etc.for connecting earthing pipe and other equipments of size 50 x 6 mm
145
-
-
Supply, Erection, testing & commissioning of 11KV, 630 Amps, Outdoor, motorised /non motorised SF6 Ring Main Unit with two Load Break Switches and one Circuit Breaker or with two Load Break Switches and two Circuit Breaker conforming to International Standards and complete with Fault Passage Indicator other accessories as required for Scada requirements of Goa electricity department & of approved make of Goa electricity department. Make: CG-Lucy /Siemens.
1
-
-
Supply, Erection, testing & commissioning of 11KV, 630 Amps, Outdoor, motorised ,non motorised ,extensible SF6 Ring Main Unit with One Siwtch and one Circuit Breaker conforming to International Standards and complete with Fault Passage Indicator other accessories as required for Scada requirements of Goa electricity department & of approved make of Goa electricity department. Make: CG-Lucy /Siemens.
1
-
-
Supply, Erection, testing & commissioning of 11KV, 400 Amps, Outdoor, oil switch fuse unit /Breaker conforming to International Standards and complete with Fault Passage Indicator other accessories as required for Scada requirements of Goa electricity department & of approved make of Goa electricity department.First fill of oil to be included. Make: Lucy .
2
-
-
Supplying and Laying of Sand (river) etc as required
15
-
-
Kaddapa of size 600mm length x 250mm width x 37mm thick as a protective cover for underground cables
300
-
-
Supply & erection of 11 Kv /433 v 250 KVA distribution transformers loss level II(Copper /Al wound) With On Load Tap Changer/Off load tap changer complete with all necessary standard fittings, outdoor type with HV - Cable Box & LV Cable Box with First Filling of Oil, as per IS 1180 (Part-I_2014).Make: Voltamp /Crompton / Bharat Bijlee /equivalent . Transformer specification as follows:
Rating: 250KVA
No load Voltage Ratio: 11/0.433 KV Quantity: 1 No. Application: Distribution Transformer
Vector Group: Dyn11(HV - Delta; LV - Star)
Temperature rise (Oil / Wdg): 40/45ºC (Amb. 50ºC)
Cooling: ONAN [ Oil Natural Air Natural]
Type of Tap changer: On Load Tap Changer Off Circuit Tap Changer
"Tapping range: +5% to -15% @ 1.25% on HV"
Impedance at 75° C: 4.5 % (Sub. To IS Tol.)
Total Losses at 50% Loading: As per 1180 level 2
Total Losses at 100% Loading: As per 1180 level 2
Termination- HV / LV: HV : Cable Box / LV : Cable Box
Orientation between HV & LV: 180°
Installation: Outdoor
Reference Standards: IS : 1180 [Energy Efficiency Level II] Make: Voltamp /Crompton / Bharat Bijlee /equivalent
1
-
-
Supply & Installation of LT 250 KVA On-Load, Linear roller type Automatic Voltage Regulator. GLobe / GLOBAL / Servokon make or equivalent, Rolling Contact type AUTOMATIC VOLTAGE REGULATOR with following data : INPUT VOLTAGE : 340 Volts to 460 Volts, 3-Ph, 50 Hz A.C.
OUTPUT VOLTAGE : 415 Volts ± 1 %, 3-Ph, 50 Hz A.C.
CAPACITY : 250 KVA
DUTY CYCLE : 100 % Continuous
COOLING : ONAN (With first filling of Trf. Oil)
1
-
-
Supply design and installation of LT panel comprising of Main Incomer MCCB 400Amps with 400Amps bypass switch .Panel shouldbe designedforoutdoor standalone application.The panel should comprise all accessories so as to allow the bypass of the AVR in case failure.Necessary electrical interlock is to be provided.Makeof swictgear: Socomec /Schneider /equivalent.
1
-
-
Supply design and installation of LT panel as suitable for load 150 KVA to 400 KVA having Incomer isolation /protection ACB /MCCB , Automatic changer over arrangement with ATS ,outgoing feeder MCCBs / MCB's , indication Lamps LT panel, CT's ,PTs',Capacitor bank of 60 KVAr - 200 KVAr APFCR panel , thyristor and haronics resistant in between the transformer and AVR along with byepass switch.Switchgear Make: Schneider /L&T/Siemens /equivalent .BMS to be incorporated ,microprocessor system
1
-
-
Supply, Erection, testing & commissioning of 11KV, 3 phase, Straight through joint kit , heat shrinkable kit complete, for 11 KV XLPE cable of size 3 x 25 sq.mm - 150sq.mm including sockets/lugs/connectors etc. Make : 3 M/ Raychem.
15
-
-
Supply, Erection, testing & commissioning of 11KV, 3 phase, Straight through joint kit , heat shrinkable kit complete, for 11 KV XLPE cable of size 3 x 150 sq.mm - 300sq.mm including sockets/lugs/connectors etc. Make : 3 M/ Raychem.
14
-
-
Reinstatment of roads ,concrete, pavers ,tiles after laying the cables etc as required.
10
-
-
Supply and installation of fire safety buckte with sand etc as required
4
-
-
supply and instalaltion of fire extinguisher CO2 type with base 4 Kg or more cylinder along with holder on wall surface etc as required.
2
-
-
supply and fixing first aid kits etc as required.
2
-
-
supply and laying shock proof rubber mat of size 2 mtrs x 1 mtr x 2mm etc as required
2
-
-
supply and fixing fire bucket stands suitable for installaltion of two or more fire safety buckets etc as required
1
-
-
Job of disconnecting existing main panel in the panel room , the meter panel, outgoing distribution panels, DG supply , changeover supply , disconnecting its Cables ,disconnecting of glandings , removing and refitting of cable trays.Job also includes the critical job of providing temporary supply and restoring the Hotel supply at the time of erecting new panels in the same panel room with all safety measures etc as required.
1
-
-
Preparation of all drawings /slds/ Files for Govt Department for obtaining necessary approvel from RIO Electricity department, MRT margao etc. for of the scheme and releasing connection including submission of all documents by obtaining signature from from concerned authoriries in drawings and files and submission of necessary test report and other documents to RIO and Electricity Department
1
-
-
Supply ,erection ,testing & Commissioning of Cable route Marker
20
-
-
Supply ,erection ,testing & Commissioning of Modem compatible to the latest scada protocol of Goa electricity department.
2
-
-
Supply ,erection ,testing & Commissioning of DLMS protocol meter
2
-
-
Supply ,Erection ,Testing Commissioning of HDGI rung bolted ladder type /perforated trays of size 100 x 50 x 2 mm upto 600 x 50 x 2 mm with all its necessary hardwares and bends and couplers.Make: Profab / Equivalent.
10
-
-
Supply and installing of structural GI material such as angles, channels ,nut ,bolts ,etc
45
-
-
Supply design and installation of LT panel as suitable for load 50 KVA to 100 KVA having Incomer isolation /protection ACB /MCCB , Automatic changer over arrangement with ATS ,outgoing feeder MCCBs / MCB's , indication Lamps LT panel, CT's ,PTs', thyristor and haronics resistant in between the Main panel and the entrance of restaurant ..Switchgear Make: Schneider /L&T/Siemens /equivalent .BMS to be incorporated ,microprocessor system
1
-
-
Providing of fencing for the sub station yard ,fencing will be provided with MS angles duly painted of 50 x 50 x 5 mm at , angles , falts and chain link mesh. The fencing will be provided with 2 mts wide entrance door.Fencing height will be 2 mts .
30
-
-
Supply and laying of 40mm Khadi (trap metal) etc as required.
6
-
-
Supply and erection of enamelled danger board of 11 KV.
8
-
-
Earthwork in excavation by mechanical means (hydraulic excavator)/manual means in foundation pipeline trenches drain (not exceeding 1.5 m in width or 10 sq.m. on plan) including dressing of sides and ramming of bottoms, lift upto 1.5 m including getting out the excavated soil and disposal of surplus excavated soil as directed within a lead of 50 m. All kinds of soil
20
-
-
Refilling the pipeline/foundation trenches plinth sides, foundation etc. with available excavated earth in layers not exceeding 20 cm depth consolidating each layer ramming and watering lead upto 50 M and all lifts and disposal of surplus earth as directed by Engineer in Charge.
18
-
-
Rubble packing with hard laterite stone under floors including watering ramming and consolidating etc. in pipeline trenches and other foundations complete.
15
-
-
Laterite masonry in neatly dressed stones of size as specified in cement mortar 1: 4 (1 cement : 4 coarse sand) in foundation and basement.
3
-
-
Providing and laying in position cement concrete 1:2:4 (1 cement : 2 coarse sand: 4 graded granitic or basaltic stone aggregate 40 m nominal size) excluding cost of centering,
shuttering and finishing : All works upto plinth level
5
-
-
Centering & shuttering including Strutting, Propping & removal of forms for : Foundations, Footings, Bases for columns
10
-
-
12mm cement plaster 1:3 (1 cement : 3 fine sand)
11
-
-
Demolishing cement concrete 1:3:6 or richer mix including disposal of material within 50 m lead.
7
-
-
Evaluation Notes How It Works ?