Goa State Urban Development Agency Tender
View complete overview of Goa GSUDA Tender
Costs
EMD
₹ 5,21,551Document Cost
₹ 15,000Tender Fee
₹ 6,000
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2024_GSUDA_16230_1Bid Award Id
ViewTender No
f.40/3/GSUDA/E-tender/28/591Tender Authority
Goa State Urban Development Agency ViewPurchaser Address
-Website
http://eprocure.goa.gov.in
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
BOQ Items
Supplying and erecting LED square / circular Max. 14 W down
lighter/Panel Light having pressure die-cast aluminium housing, polystyrene
diffuser having system lumens output of Min. 1500 Lumens, min. efficacy of
110 lumen/W, CRI80, CCT upto 6500K, Beam Angle of 120 deg., max. ripple
of 5%, THD10%, p.f. 0.95, operating range of 120-270V, surge protection of
2.5 kV, Life class of 50,000 Hrs. at L70B50, including driver, having mounting
arrangement with board for surface type or spring loaded mounting clips
164
-
-
Supply and erecting of 9 inch (225 mm sweep) exhaust fan with double ball bearings, 1400 rpm, complete with all accessories.
56
-
-
Supplying and erecting CRCA powder coated corridor/passage light LED
fitting (4 feet) Max. 17W with high transitivity diffuser with system lumens
output of Min. 2000 lumens , min. efficacy of 120 lumen/W, CRI80, CCT
upto 6500K, Beam Angle of 120 deg., Ripple5%, THD10%, p.f. 0.95,
operating range of 120-270V, surge protection of 4 kV, Life class of 50,000 Hrs.
at L70B50, including driver, with end caps on provided PVC Block / wooden
board with 3 years warranty.
546
-
-
Supply and erecting of 48 inch ( 1200mm sweep) ceiling fan, double ball bearing type, , complete with all accessories. CAT A
148
-
-
Supplying and erecting air circulator 600 mm. sweep oscillating type, wall
mounting 1440 RPM without speed regulator, overheat protection unit, totally
enclosed, flame proof motor suitable for 230/250 volts single phase, 50 cycles
A.C. supply, core lead wire and with moisture proof treatment to winding and
with ‘E’ class insulation.
26
-
-
Supply of 4 core armoured PVC/XLPE insulated, PVC sheathed aluminium conductor cable of 1.1 KV grade with ISI mark conforming to IS:1554(Part I) ,IS:7098(Part I) with latest amendments of following size.' 4 Core 16 sq.mm
530
-
-
Supply of 3 1/2 core armoured PVC/XLPE insulated, PVC sheathed aluminium conductor cable of 1.1 KV grade with ISI mark conforming to IS:1554(Part I) ,IS:7098(Part I) with latest amendments of following size.' 3 1/2 Core 70 sq.mm
415
-
-
'Supply of 3 1/2 core armoured PVC/XLPE insulated, PVC sheathed aluminium conductor cable of 1.1 KV grade with ISI mark conforming to IS:1554(Part I) ,IS:7098(Part I) with latest amendments of following size.31/2 Core 120sq.mm
50
-
-
'Supply of 3 1/2 core armoured PVC/XLPE insulated, PVC sheathed aluminium conductor cable of 1.1 KV grade with ISI mark conforming to IS:1554(Part I) ,IS:7098(Part I) with latest amendments of following size. 31/2 Core 150sq.mm
140
-
-
'Supply of 3 1/2 core armoured PVC/XLPE insulated, PVC sheathed aluminium conductor cable of 1.1 KV grade with ISI mark conforming to IS:1554(Part I) ,IS:7098(Part I) with latest amendments of following size. 3 1/2 Core 300 sq.mm
140
-
-
Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of size not exceeding 25 sq.mm in the existing RCC/HUME/STONEWARE Metal pipe, etc. complete as required.
15
-
-
Laying of one number PVC insulated and PVC sheathed/XLPE power cable of 1.1 KV grade of size not exceeding 25 sq.mm in the existing masonry open duct, etc. complete as required
450
-
-
Laying of one number PVC insulated and PVC sheathed/XLPE power cable of 1.1 KV grade of size not exceeding 25 sq.mm on surface, etc. complete as required
65
-
-
'Supply of following size of 3 core, HV, 11 KV grade, ISI mark, XLPE cable with stranded compact circular aluminium conductor, conductor screened with extruded semiconducting compound, XLPE insulated, insulation screned with extruded semiconducting compound in combination with copper tape(0.3 KA for 1Sec.) cores laid off,inner sheath of PVC tape,galvanised steel flat strip armoured and overall PVC sheathed cable conforming to IS:7098(Part II) with latest amendments. 3 Core 150 sq.mm
250
-
-
'Supply of following size of 3 core, HV, 11 KV grade, ISI mark, XLPE cable with stranded compact circular aluminium conductor, conductor screened with extruded semiconducting compound, XLPE insulated, insulation screned with extruded semiconducting compound in combination with copper tape(0.3 KA for 1Sec.) cores laid off,inner sheath of PVC tape,galvanised steel flat strip armoured and overall PVC sheathed cable conforming to IS:7098(Part II) with latest amendments. 3 Core 300sq.mm
350
-
-
Laying of one number PVC insulated and PVC sheathed/XLPE power cable of grade exceeding 11 KV but not exceeding 33 KV grade of size exceeding 120 sq.mm but not exceeding 400 sq.mm direct in ground including excavation in the form of a trench as per Cable Trench Drawing provided by the Engineer-Incharge,sand cushioning with screened sand bed of 20mm thick , protective covering with bricks placed lenghtwise on top of cable all over the run and backfilling the excavated earth without stones or hard material and making the surface proper with 15 cm crown on the top complete as required. Soily strata
150
-
-
Laying of one number PVC insulated and PVC sheathed/XLPE power cable of grade exceeding 11 KV but not exceeding 33 KV grade of size exceeding 120 sq.mm but not exceeding 400 sq.mm direct in ground including excavation in the form of a trench as per Cable Trench Drawing provided by the Engineer-Incharge,sand cushioning with screened sand bed of 20mm thick , protective covering with bricks placed lenghtwise on top of cable all over the run and backfilling the excavated earth without stones or hard material and making the surface proper with 15 cm crown on the top complete as required.Rocky strata
490
-
-
Laying of one number PVC insulated and PVC sheathed/XLPE power cable of 1.1 KV grade of size exceeding 120 sq.mm but not exceeding 400 sq.mm direct in ground including excavation in the form of a trench as per Cable Trench Drawing provided by the Engineer-Incharge,sand cushioning with screened sand bed of 20mm thick , protective covering with bricks placed breadth-wise on top of cable all over the run( the brick protection shall cover the cable and project atleast 5 cms over the sides of the cable)and backfilling the excavated earth without stones or hard material and making the surface proper with 15 cm crown on the top complete as required.'(a) In soily strata
140
-
-
Laying of one number PVC insulated and PVC sheathed/XLPE power cable 1.1 KV grade of size exceeding 120 sq. mm but not exceeding 400 sq. mm on surface, etc complete as rewquired
15
-
-
Laying of one number PVC insulated and PVC sheathed/XLPE power cable of 1.1 KV grade of size exceeding 25 sq.mm but not exceeding 400 sq.mm in the existing masonry open duct, etc. complete as required.
35
-
-
Laying of one number PVC insulated and PVC sheathed/XLPE power cable of 1.1 KV grade of size exceeding 25 sq.mm but not exceeding 400 sq.mm in the existing masonry open duct, etc. complete as required
585
-
-
Laying of one number PVC insulated and PVC sheathed/XLPE power cable of 1.1 KV grade of size exceeding 25 sq.mm but not exceeding 120 sq.mm in the existing masonry open duct, etc. complete as required
50
-
-
Laying of one number PVC insulated and PVC sheathed/XLPE power cable of 1.1 KV grade of size exceeding 120 sq.mm but not exceeding 400 sq.mm on surface, etc. complete as required
10
-
-
Supplying and making cable end terminations with brass compression gland and copper lugs for folowing sizes of 4 Core PVC insulated PVC sheathed/XLPE aluminium conductor cable of 1.1 KV grade, complete as required.'(5) 4 x 16 Sq. mm.
14
-
-
Supplying and making cable end terminations with brass compression gland and copper lugs for folowing sizes of 3 1/2 Core PVC insulated PVC sheathed/XLPE aluminium conductor cable of 1.1 KV grade, complete as required.'(4) 3 1/2 x 70 Sq. mm.
18
-
-
Supplying and making cable end terminations with brass compression gland and copper lugs for folowing sizes of 3 1/2 Core PVC insulated PVC sheathed/XLPE aluminium conductor cable of 1.1 KV grade, complete as required.'(6) 3 1/2 x120 Sq. mm.
2
-
-
Supplying and making cable end terminations with brass compression gland and copper lugs for folowing sizes of 3 1/2 Core PVC insulated PVC sheathed/XLPE aluminium conductor cable of 1.1 KV grade, complete as required.'(6) 3 1/2 x150 Sq. mm.
4
-
-
Supplying and making cable end terminations with brass compression gland and copper lugs for folowing sizes of 3 1/2 Core PVC insulated PVC sheathed/XLPE aluminium conductor cable of 1.1 KV grade, complete as required(10) 3 1/2 x 300 Sq. mm.
6
-
-
Supplying and Installing following size perforated type 14 SWG, M.S.cable tray of GI pregalvanised/hot dip galvanised/ powder coated finish, in convenient sections, joined with connectors, suspended from 450mm width x 50mm depth the ceiling with suitable MS suspenders including bolts and nuts, painting suspenders etc, complete as required.450mm width x 50mm depth
480
-
-
Supplying and Installing following size perforated type 16 SWG, M.S.cable tray of GI pregalvanised/hot dip galvanised/ powder coated finish, in convenient sections, joined with connectors, suspended from the ceiling with suitable MS suspenders including bolts and nuts, painting suspenders etc, complete as required.300mm width x 50mm depth
480
-
-
Earthing with copper earth plate 600 mm x 600 mm x 3 mm thick including accessories and providing masonry enclosure with CI/RCC cover having locking/lifting arrangement and watering pipe etc. (but without charcoal or coke and salt) as required as per the Earthing Drawing provided by the Engineer-Incharge.The scope of work includes the following: a) Excavation of pit of size 1.0x1.0x 3.0 mtrs(min) and disposal of excavated soil. c)Watering GI pipe, 20 mm Class B, with funnel as per specs. d) Charcoal/salt as per specs ( paid seperately). e) Refilling the pit of size 1.0x1.0x 3.0 mtrs(min) with soft black agriculture soil of minimum resistivity i/c transportation. e)Masonary chamber with proper foundation, cover plate and locking arrangement. f) Testing of earth value with earth megger and certifications of its value. g)watering arrangement(plumbing will be paid seperately).
6
-
-
Earthing with GI earth plate 600 mm x 600 mm x 6 mm thick including accessories and providing masonry enclosure with CI/RCC cover having locking/Lifting arrangement and watering pipe etc. (but without charcoal or coke and salt) as required as per the Earthing Drawing provided by the Engineer-Incharge.The scope of work includes the following: a) Excavation of pit of size 1.0x1.0x 3.0 mtrs(min) and disposal of excavated soil. c)Watering GI pipe, 20mm, Class B, with funnel as per specs. d) Charcoal/salt as per specs ( paid seperately). e) Refilling the pit of size 1.0x1.0x 3.0 mtrs(min) with soft black agriculture soil of minimum resistivity i/c transportation. e)Masonary chamber with proper foundation, cover plate and locking arrangement. f) Testing of earth value with earth megger and certifications of its value. Aluminium tag with embossed earthing value to be attached to the pipe.g)watering arrangement(plumbing will be paid seperately).
14
-
-
Providing and fixing 25 mm x 5 mm copper strip on surface r in recess for coneections etc. as required
80
-
-
Providing and fixing 25 mm x 5 mm GI strip on surface or in recess for coneections etc. as required
350
-
-
Providing and fixing 4 mm dia copper wire on surface or in recess for loop Earthing . as required
50
-
-
Providing and fixing 6 SWG dia GI wire on surface or in recess for loop Earthing . as required
1000
-
-
Extra for using salt and charcoal for GI or copper plate earth electrode as required( 96 Kgs of Charcoal and 5 Kgs of Salt)
22
-
-
Supplying, erecting, testing & commissioning 11 kV, 630A, 21kA/3sec, 3 way
outdoor, extensible motorised SCADA compatible RMU, internal arc tested
consisting of 2 nos. feeder with 2 LBS and 1 no. feeder with 1 VCB. compliant to
IEC 62271 -100, 200 and 102, as per specification no. SW-HTS/RMU SCADA
1
-
-
Supplying, erecting, testing & commissioning 11kV, 630A, 21kA/3sec, 4 way
outdoor, extensible motorised SCADA compatible RMU, internal arc tested
consisting of 2 nos. feeder with 2 LBS and 2 nos. feeder with 2 VCB compliant to
IEC 62271 -100, 200 and 102, as per specification no. SW-HTS/RMU SCADA
2
-
-
Supplying and making Indoor cable end termination with heat shrinkable kit for following sizes of PVC insulated PVC sheathed/XLPE aluminium conductor cable upto 11 KV grade, complete as required.'(c) 11 KV, 3 Core x 120 - 185 sq.mm
2
-
-
Supplying and making Indoor cable end termination with heat shrinkable kit for following sizes of PVC insulated PVC sheathed/XLPE aluminium conductor cable upto 11 KV grade, complete as required.'(d) 11 KV, 3 Core x 240 - 300sq.mm
4
-
-
Supplying and making Outdoor cable end termination with heat shrinkable kit for following sizes of PVC insulated PVC sheathed/XLPE aluminium conductor cable upto 11 KV grade, complete as required.(d) 11 KV, 3 Core x 240 - 300sq.mm
1
-
-
Supplying, installing, testing & commissioning 3 phase, 11/0.433 kV, 50 Hz., 400
kVA, Mineral oil immersed and naturally cooled outdoor type, Copper wound
Non-sealed transformer delta/star connected with additional neutral brought out
on load side, temperature rise should not exceed 45℃ by thermometer in oil and
50℃ by the resistance method in winding at full load rating, using type A
winding insulation (kraft paper) with HV tapping (with off load tap changer)
off load +5 to -10 in steps of 2.5%, having 7 number of tap positions with
standard accessories complete with test certificate with losses below 1225 Watts
at 50% load, 3450 Watts at 100% load as per IS:1180 (part 1) : 2014 with
necessary permissions of Electrical Inspector, as per specification no SS- TRNSL.
1
-
-
Supplying and erecting fencing of section having size 2450 mm in height from ground level and 1200 mm width with angle iron frame work erected in C C foundationand painted
as per specification No SS-AS/FSG
12
-
-
Supplying and erecting double leaf hinged dooreach1500mm in width x 1850 mm in height using B class ,GI pipe with angle iron supports, chain link wiremesh (jali) complete supported on channel iron, erected in foundation, and painted as per specification no SS-AS/DLD
1
-
-
Supplying & erecting Carbon Dioxide (CO2) fire extinguisher of 4.5 kg.
capacity cartridge type conform to IS 2878 /15683 complete erected with
necessary clamp made from 50 x 6 mm. M. S. flat with nut & bolts routed in wall
complete.
10
-
-
Supplying and fixing following way SPN sheet steel MCB distribution board 240 V on surface/ recess complete with tinned copper busbar neutral busbar earth bar dinnbar detachable gland plate interconnections phosphotized and powder painted including earthing etc. as required ( but without MCB/RCCB/Isolator)'(n) 8 way double door Cat B
10
-
-
Supplying and fixing following way SPN sheet steel MCB distribution board 240 V on surface/ recess complete with tinned copper busbar neutral busbar earth bar dinnbar detachable gland plate interconnections phosphotized and powder painted including earthing etc. as required ( but without MCB/RCCB/Isolator)'(o) 12way double door Cat B
80
-
-
Supplying and fixing following way TPN sheet steel, double door, Horizontal type MCB distribution board 415 V on surface/ recess complete with tinned copper busbar neutral busbar earth bar dinnbar detachable gland plate interconnections phosphotized and powder painted including earthing etc. as required ( but without MCB/RCCB/Isolator)(f) 4 way (4+12), double door, Horizontal type Cat B
5
-
-
Supplying and fixing following way TPN sheet steel, single door, Horizontal type MCB distribution board 415 V on surface/ recess complete with tinned copper busbar neutral busbar earth bar dinnbar detachable gland plate interconnections phosphotized and powder painted including earthing etc. as required ( but without MCB/RCCB/Isolator) 6way (8+18), double door, Horizontal type Cat B
7
-
-
Supplying and fixing 6 A to 32 A, C series MCB suitable for lighting and other loads of following poles in the existing MCB DB complete with connections testing and commissioning etc as required.(a) SP, Cat A
352
-
-
Supplying and fixing 6 A to 32 A, C series MCB suitable for lighting and other loads of following poles in the existing MCB DB complete with connections testing and commissioning etc as required. DP, Cat A
101
-
-
Supplying and fixing 40 A, C series MCB suitable for lighting and other loads of following poles in the existing MCB DB complete with connections testing and commissioning etc as required.(d) TP, Cat A
30
-
-
Supplying and fixing 63 A, C series MCB suitable for lighting and other loads of following poles in the existing MCB DB complete with connections testing and commissioning etc as required. (e) TPN, Cat A
1
-
-
'Supplying and fixing following rating double pole (single pole and neutral) 240 V RCCB having a sensitivity current upto 300mA in the existing MCB DB complete with connections testing and commissioning etc as required(b) 40 A, Cat A
30
-
-
Supplying and fixing following rating four pole (triple pole and neutral) 415 V RCCB having a sensitivity current upto 300mA in the existing MCB DB complete with connections testing and commissioning etc as required'(b) 40 A, Cat A
28
-
-
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor single core cable in the independent surface / recess PVC conduit ( medium)of appropriate size as required.'(b) 2 x 2.5 sq.mm + 1 x 2.5 sq.mm earthwire (20mm Conduit)
2395
-
-
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor single core cable in the independent surface / recess PVC conduit ( medium)of appropriate size as required.2 x 4 sq.mm + 1 x 4 sq.mm earthwire (20mm Conduit)
2610
-
-
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor single core cable in the independent surface / recess PVC conduit ( medium)of appropriate size as required.'4 x 4 sq.mm + 2 x 4 sq.mm earthwire (25mm Conduit)
500
-
-
Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in recessed PVC conduit(heavy) with modular switch, modular plates, suitable size modular GI box of specified Category and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required. Group B -- with Cat A Modular Accessories
998
-
-
Wiring for plug on board with Switch socket surface/concealed type, copper wiring and earthing and with modular accessories as per specification No: WGPW/CW
139
-
-
Wiring for twin control light point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in recessed PVC conduit(heavy) with 2 way modular switch, modular plates, suitable size modular GI box of specified Category and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required.
4
-
-
Wiring for group controlled light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in recessed PVC conduit(heavy) and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required.
91
-
-
Supplying and fixing suitable size modular PVC box with modular plate and cover in front on surface or in recess including providing and fixing 1 no 6 pin 15/16 A modular socket outlet and 1 nos 15/ 16 A modular switch connection painting etc. as required. ( For workstations)(a) Cat A
118
-
-
Supplying and fixing suitable size modular PVC box with modular plate and cover in front on surface or in recess including providing and fixing 3 pin 5/6 A modular socket outlet and 5/ 6 A modular switch connection painting etc. as required. (a) Cat A
214
-
-
Supplying and fixing PVC synthetic elastomer electrically insulating mat with class B insulation conforming to IS: 15652 – 2006 & CPRI tested having 2.5 mm thickness upto 11 Kv
10
-
-
L.V PANEL DESIGN 'Fabrication , Supply , Installation , Testing and Commissioning Of Outdoor Main L.V. Panel made out of 14 Swg CRCA sheet , Degreased , derusted and painted with two coats of red oxide primer and two coats of Siemens grey epoxy paint and conforming to IP 54 class of protection . The panel shall be suitable for three phase 415V , 50 Hz. , four wire AC system and shall comprise of the following :Along with necessary stand and earthting brought forward for necesaary connection on both side of panel 'INCOMER'500 amps 4pole,36 KA MCCB, with neutral contactor,'Sets1'0-500 Volts digital electronic volt meter with selector switch shall be protected by 2 amps TP MCB's.'Sets1'0- 500 Amps digital electronic ammeter with selector switch and 15/5 amps 15 VA, CL 3CTs .'Sets1'Breaker ON / OFF / TRIP indicating lights with control MCB’s.'Set1'RYB Lamp Mcb 'Set1'Under voltage release'Set1 '230 V AC Shunt trip coil'Set1'Under voltage relay with timer (27)'Set1'Over voltage relay with timer (59)'Set1 '3Nos. 600/ 5 amps , 15 VA Class I CT’s.suitable for breaker 'Set1'BUSBAR '800 amps ,415 V TPN 50 Hz Aluminium bus bars with heat shrinkable insulation sleeve.'Set1 ' OUTGOING '500 A 4 Pole MCCB ,36KA 'Set1 'SPARE FEEDER'200 amps 4 pole MCCB ,36 KA'Set 1 ,'100 amps 4 pole MCCB , 36 KA 'Set1 ,with modem and 3 phase meter as per ged requirement
1
-
-
MAIN LT PANEL DESIGN 'Fabrication , Supply , Installation , Testing and Commissioning Of Indoor Main L.t. Panel made out of 14 Swg CRCA sheet , Degreased , derusted and painted with two coats of red oxide primer and two coats of Siemens grey epoxy paint and conforming to IP 54 class of protection . The panel shall be suitable for three phase 415V , 50 Hz. , four wire AC system and shall comprise of the following :Along with necessary stand and earthting brought forward for necesaary connection on both side of panel 'INCOMER '500 amps 4pole,36 KA MCCB, with neutral SET 1 '0-500 Volts digital electronic volt meter with selector switch shall be protected by 2 amps TP MCB's.SET 1'0- 500 Amps digital electronic ammeter with selector switch and 15/5 amps 15 VA, CL 3CTs .SET 1'Breaker ON / OFF / TRIP indicating lights with control MCB’s.SET 1'RYB Lamp Mcb required SET 1'Under voltage releaseSET 1'230 V AC Shunt trip coil SET 1'Under voltage relay with timer (27)SET 1 'Over voltage relay with timer (59)SET 1'3Nos. 600/ 5 amps , 15 VA Class I CT’s.suitable for breaker SET 1. Sufficient cooling louvers 'BUSBAR '800 amps 415 V TPN aluminium bus bars with heat shrinkable insulation sleeve. SET 1' OUTGOING '160 amps 4 pole MCCB ,36 KA common area , SET 2 '100 amps 4 pole MCCB , 36 KA ground floor feeder LHS & RHS , SET 2 '63 amps 4 pole MCCB ,36 KA FIRST FLOOR FEEDER LHS & RHS, SET 4 '100 amps 4 pole MCCB , 36 KA 2ND FLOOR AND 3RD FLOOR LHS RHS FEEDER ,SET 2'SPARE FEEDER '100 amps 4 pole MCCB , 36 KA ,
1
-
-
'Common Area Power Panel 'Fabrication , Supply , Installation , Testing and Commissioning Of COMMON PANEL made out of 14 Swg CRCA sheet , Degreased , derusted and painted with two coats of red oxide primer and two coats of Siemens grey epoxy paint and conforming to IP 54 class of protection . The panel shall be suitable for three phase 415V , 50 Hz. , four wire AC system and shall comprise of the following :Along with necessary stand and earthting brought forward for necesaary connection on both side of panel 'Mains incomer 'INCOMER'16 0Amps 4 pole MCCB, 25KA SET 1 'Breaker ON / OFF / TRIP indicating lights with control MCB’s.SET 1 'Under voltage releaseSET 1 '230 V AC Shunt trip coilSET 1 ''Under voltage relay with timer (27)SET 1 Over voltage relay with timer (59)SET 1 '3 Nos. 200/ 15amps, 15 VA Class I CT’s.digital analog meterSET 1 'DG incomer '160 Amps 4 pole MCCB, 25KA SET 1 'Breaker ON / OFF / TRIP indicating lights with control MCB’s.SET 1 'Under voltage releaseSET 1 '230 V AC Shunt trip coilSET 1 'Under voltage relay with timer (27)SET 1 'Over voltage relay with timer (59)SET 1 'AUTO CHANGEOVER SWITCHSET 1 '200 amps TPN Auto Changeover switch with standard protectionsSET 1 Phase Indicating lights for both sources with control MCB’s.SET 2 BUSBAR'300 amps 415 V,TPN aluminium bus bars with heat shrinkable insulation sleeve.SET 1 'OUTGOING'Main outgoing '160 Amps 4 pole MCCB, 25KA SET 1 '0-500 Volts digital electronic volt meter with selector switch shall be protected by 2 amps TP MCB's.SET 1 '0- 400 Amps digital electronic ammeter with selector switch and 15/5 amps 15 VA, CL 3CTs .SET 1 'Breaker ON / OFF / TRIP indicating lights with control MCB’s.SET 1 'Under voltage release SET 1 '230 V AC Shunt trip coilSET 1 'Under voltage relay with timer (27)SET 1 'Over voltage relay with timer (59)SET 1 '3 Nos. 250/ 15amps, 15 VA Class I CT’s.SET 1 'Outgoing feeder'160 Amps 4 pole MCCB, 25KA SET 1 ,63A FP MCB 25 KA SET 5 ,'40A FP MCB 25 KA SET 3 ',100 Amps 4 pole MCCB 25KA SET 1 'Spare Feeder '63A FP MCB 25 KA SET 3 ,'25 A DP MCB 25 KA SET 1 ,'40 A FP MCB 25 KA SET 1, '16 A SP MCB 25 KA SET 4
1
-
-
Floor panel 'Fabrication , Supply , Installation , Testing and Commissioning made out of 14 Swg CRCA sheet , Degreased , derusted and painted with two coats of red oxide primer and two coats of Siemens grey epoxy paint and conforming to IP 54 class of protection . The panel shall be suitable for three phase 415V , 50 Hz. , four wire AC system and shall comprise of the following :Along with necessary stand and earthting brought forward for necesaary connection on both side of panel 'INCOMER '100 Amps 4 pole MCCB, 25KA SET 1 '0-500 Volts digital electronic volt meter with selector switch shall be protected by 2 amps TP MCB's.SET 1'0- 100 Amps digital electronic ammeter with selector switch and 100/5 amps 10 VA, CL 1 CTs .SET 1'Breaker ON / OFF / TRIP indicating lights with control MCB’s.SET 1'Under voltage release SET 1'230 V AC Shunt trip coil SET 1'Under voltage relay (27) SET 1'Over voltage SET 1'3 Nos. 160/ 15amps, 15 VA Class I CT’s.SET 1'BUSBAR'250 amps 415 V,TPN aluminium bus bars with heat shrinkable insulation sleeve.SET 1'OUTGOING ' PROVISION Single phase digital Meter SET 18 '25 Amps SP MCB 10K A ,Along With PROVISION Three phase digital Meter SET 5 '25Amps TP MCB 10K A ,
7
-
-
Floor panel 'Fabrication , Supply , Installation , Testing and Commissioning made out of 14 Swg CRCA sheet , Degreased , derusted and painted with two coats of red oxide primer and two coats of Siemens grey epoxy paint and conforming to IP 54 class of protection . The panel shall be suitable for three phase 415V , 50 Hz. , four wire AC system and shall comprise of the following :Along with necessary stand and earthting brought forward for necesaary connection on both side of panel 'INCOMER '100 Amps 4 pole MCCB, 25KA SET 1 '0-500 Volts digital electronic volt meter with selector switch shall be protected by 2 amps TP MCB's.SET 1'0- 100 Amps digital electronic ammeter with selector switch and 100/5 amps 10 VA, CL 1 CTs .SET 1'Breaker ON / OFF / TRIP indicating lights with control MCB’s.SET 1'Under voltage release SET 1'230 V AC Shunt trip coil SET 1'Under voltage relay (27) SET 1'Over voltage SET 1'3 Nos. 160/ 15amps, 15 VA Class I CT’s.SET 1'BUSBAR'250 amps 415 V,TPN aluminium bus bars with heat shrinkable insulation sleeve.SET 1'OUTGOING ' PROVISION for Single phase digital Meter SET 20 '25 Amps SP MCB 10K A ,Along With PROVISION for Three phase digital Meter SET 3 '25Amps TP MCB 10K A ,
1
-
-
Supplying, erecting, testing and commissioning of diesel generating set with
alternator of 100 kVA output continuous rating, 3 Phase, 415 V, 50c/s 0.8 p. f.
A.C supply, a totally enclosed air cooled / liquid cooled multi-cylinder diesel
engine developing suitable BHP at 1500 rpm with 10% overload for 1 hour in 12
hours, along with standard accessories, self-excited, self-regulated, screen
protected alternator with static excitation system running at 1500 RPM as per IS
4722-2001 with voltage regulation +/- 5 %, with performance class G2 and
maximum fuel consumption 17.4 Ltr/hr @75% loading. Both the engine and
alternator direct coupled on a common fabricated steel base frame and mounted
on anti-vibrating pads with standard control panel comprising meters, switchgears,
indicators connected with suitable wires/cables, the complete set enclosed in
composite Acoustic enclosure as fully assembled integral unit made of 16 SWG
CRCA Sheet, sound absorbing material to restrict sound level up to 75 dB at 1.0
m, provided with first filling of oil, diesel not less than 230 Ltr etc. on
provided M20 Grade CC Foundation as per specification no. GEN-DG
1
-
-
Supplying and erecting integrated LED street light fitting 70-75W IP65 & IK08 class having single piece pressure die-cast aluminium housing, having system lumens output of Min. 7700 Lumens, min. efficacy of 110 lumen/W, CRI70, CCT upto 6500K,THD0.95, operating range of 140-270V, inbuilt surge protection of 10 kV, Life class of 50,000 Hrs. at L70B50, including driver complete with 3 Years warranty as per specification No FG-ODF/FLS2.
10
-
-
Providing & erecting 7 m high (clear height) galvanised octagonal pole with
foundation bolts having bottom of 130 mm A/F, top 70 mm A/F on provided
foundation as per specification no. OH-PL/OPL
10
-
-
Supplying and erecting Street light bracket for erection of Single fitting made
from 40 mm. dia ‘B’ class G.I. pipe 1.0 m. in length along with pole cap of 300
mm length 100 mm dia duly welded as per specification no. FG-BKT/BPC
10
-
-
SITC of Electric Traction Passenger Lift with• Rated capacity :- 8Passenger/540Kg• Floors :- G+1 floor (2Stops/2 Landings)• Travel :- 3 to 4.2 mtrs• Location of Lift Machine:- MR/MRL• Rated speed :- 1.0mps VS• Doors type :- COPO/TOPO Doors with frame having clear opening of 800 mm wide x 2000 mm high made from SS 304 grade sheet of 1.5mm, thick in hairline finish for car and all
landing doors with SS door rchitraves/frames• Lift car enclosure made from SS 304 grade sheet of 1.5mm, thick with hairline finish with frame made from MS girders, bracing of
adequate size with minimum safety factor of 5, with Toe Guard Apron, with necessary false ceiling with adequate LED lights, blower/fan for ventilation & SS chequered plate flooring,
handrails, mirror, emergency light etc.• COP with SS face plate having metallic push buttons with Braille Code & luminous indicator around button with FPI, scrolling
UP/DN LED indicator & with/without attendant key switch, OWD with audio-visual alarm, VAS in Marathi, Hindi & English with intercom system with telephone instrument in Lift car, LMR & FCC/ground floor• Clear Car size of ......mm wide x ......mm deep x ......mm high • LOP with SS face plate having recess/surface push button box for all landings with scrolling UP/DN LED indicator having metallic push buttons with Braille Code & luminous indicator around button with CPI, Lift car arrival & next travel direction audio-visual indication at all landings • Lift controller based on microprocessor/ PLC with VVVF Drive having closed loop control system, with IBMS compatible having necessary port, control panel duly wired with proper size & strength copper wire for power & control circuit, with provision for addition of floor/control card & allied accessories control panel having enclosure of 1.5mm CRCA sheet with powder coating with IP54 Protection class
• ARD complete with necessary SMF VRLA batteries• Fireman controller having fireman switch at fire Landing,• CCTV surveillance system comprises of 2nos minimum 2.0MP FHD IP based vandal proof Dome camera in lift car & in LMR/inside lift shaft top aimed on Lift machinery & controller
with NVR kept in LMR/FCC with HDR data backup for 60 Days with 18" FHD TV monitor, to be kept in FCC/LMR as directed by Engineer In Charge. • Lift Machine of Gearless PMSM of suitable kW with Traction pulley, OSG, electromagnetic brakes, entire assembly mounted
on adequate size girders duly fixed on LMR floor/ shaft walls
complete with main/diverter traction sheaves, suspension wire
ropes/belts of adequate size & strength• Other mechanical parts such as 'T' section adequate size guide rails for car & counter weight with brackets fasteners, counter
weight frame with necessary blocks, buffers with necessary support arrangement, MS pit ladder etc. erected with necessary steel work • Minor civil work for alteration if any and erection of door frames and accessories, erection buffers, erection of lift machinery, adequate size core cuts if required & scaffolding for erecting
guide rails fixing of girders for mounting lift machine etc. complete as per specification no. LFT.MAHARASHTRA PWD CSR 2018-19, I No: - 17-1-3 Notes
1) General: - Job includes entire procedure of obtaining all
necessary erection permissions & "License to Work the Lift"
from Electrical Inspector(Lifts) with submission to the Engineer
In Charge.
2) Warrantee: - Job covers three years onsite warrantee for all the
Lift parts with FCAMC as per the maintenance schedule.
2
-
-
ADD ON for LIFT For Lift having 800mm wide x 2000mm high clear entrance in 1.5mm thick SS 304 grade landing door [Two panel], this includes all necessary accessories like LOP's with UP/DN buttons-arrowsindicators, extension of guide rails, shaft wiring with trunking, traveling cables, main hoisting ropes/belts, & OSG rope landing doors with all accessories etc. necessary for the normal safe functioning of lift installation complete
4
-
-
For Lift car having 800mm wide x 2000mm high clear entrance
having 1.5mm thick SS 304 grade sheet car door [Two panel] complete with required accessories like door operator mechanism with drive, required Aluminium sill, infrared curtain & necessary wiring with interlocking arrangement etc. complete
4
-
-
For Full Collective control system, add as below. 1 For Lift travelling above First floor & up to Sixth floor
2
-
-
Supplying, installation, testing and commissioning of main fire pump (MFP /
EP) suitable for water discharge of 1600 to 1800 LPM at 70 to 55 m head
driven by electric motor 415 volts, 3 phase 50 Hz, AC supply of 30kW or of
suitable kW capacity for manual/automatic operation and consisting of following
:
(a) Horizontal type, single stage, centrifugal/split casing pump of cast iron body &
bronze impeller with stainless steel shaft (SS410 grade), mechanical seal
conforming to IS 1520.
(b) Squirrel cage induction motor, TEFC, synchronous speed 3000 RPM, suitable
for operation with IP 55 protection for enclosure, horizontal foot mounted type
with Class-'F' insulation, conforming to IS-325.
(c) M.S. fabricated common base plate, coupling, coupling guard, foundation bolts
etc. as required.
(d) Erected on provided suitable size cement concrete foundation duly plastered
with anti vibration pads with perfect aligning, proper levelling complete pump set
with accessories duly painted with two coats of synthetic enamel paint of fire red
colour over a coat of primer (ISC code 536 as per IS 2932 of 2003) complete, as
per specification no. FF-MFP/SSC/EP
1
-
-
Supplying, installation, testing and commissioning of main fire pump
(MFP/DP) suitable for water discharge of 1600 to 1800 LPM at 70 to 50 m
head driven by 45 HP or suitable HP capacity diesel engine at required
working speed suitable for manual/automatic operation and consisting of
following :
(a) Horizontal type, single stage, centrifugal casing pump of cast iron body &
bronze impeller with stainless steel shaft (SS410 grade), mechanical seal
conforming to IS 1520.
(b) Water cooled with radiator, diesel engine conforming to relevant IS standard
complete with auto starting mechanism, 12/24 volts DC electric starting
equipment with battery of required AH capacity with necessary charger suitable to
work on 230v, 50Hz AC supply, diesel tank of minimum 150ltr capacity with first
filling of diesel up to 100% level with necessary piping with valves up to engine,
exhaust pipe extended up to 10 m outside pump house duly insulated with 50 mm
thick glass wool with 1.0 mm thick aluminium sheet cladding, residential silencer,
instruments and protection as per standard specification, stop solenoid for auto
stop in the event of fault with audio indications etc. as required.
(c) M.S. fabricated common base plate, coupling, coupling guard, foundation bolts
etc. as required.
(d) Erected on provided suitable size cement concrete foundation duly plastered
with anti vibration pads with perfect aligning, proper levelling complete pump set
with engine assembly and accessories duly painted with two coats of synthetic
enamel paint of fire red colour over a coat of primer (ISC code 536 as per IS 2932
of 2003) complete, as per specification no. FF-MFP/SSC/DP
1
-
-
Supplying, installation, testing and commissioning of jockey fire pump (JP)
suitable for water discharge of 180 to 240 LPM at 70 to 50 m head driven by
electric motor 415 volts, 3 phase 50 Hz, AC supply of 5.5 kW or of suitable
kW capacity for manual/automatic operation and consisting of following :
(a) Horizontal/vertical type, multi stage, centrifugal casing pump of cast iron body
& bronze impeller with stainless steel shaft (SS410 grade), mechanical seal
conforming to IS 1520.
(b) Squirrel cage induction motor, TEFC, synchronous speed 3000 RPM, suitable
for operation with IP 55 protection for enclosure, horizontal foot mounted type
with Class-'F' insulation, conforming to IS-325.
(c) M.S. fabricated common base plate, coupling, coupling guard, foundation bolts
etc. as required.
(d) Erected on provided suitable size cement concrete foundation duly plastered
with anti vibration pads with perfect aligning, proper levelling complete pump set
with accessories duly painted with two coats of synthetic enamel paint of fire red
colour over a coat of primer (ISC code 536 as per IS 2932 of 2003)complete, as
per specification no. FF-MFP/JP
1
-
-
Supplying and installing air vessel of 300 mm dia 1.5m in height M.S. tank installed inside pump house / on terrace complete as per specification no. FF-FFA/ACT
3
-
-
Supplying and erecting G.I. pipe above ground of ‘C’ class ERW of size 200 mm dia with necessary fittings complete as per specification no. FF-PP
10
-
-
Supplying and erecting G.I. pipe above ground of ‘C’ class ERW of size 150 mm dia with necessary fittings complete as per specification no. FF-PP
180
-
-
Supplying and erecting G.I. pipe above ground of ‘C’ class ERW of size 100 mm dia with necessary fittings complete as per specification no. FF-PP
40
-
-
Supplying and erecting G.I. pipe above ground of ‘C’ class ERW of size 75/80 mm dia with necessary fittings complete as per specification no. FF-PP
220
-
-
Supplying and erecting G.I. pipe above ground of ‘C’ class ERW of size 65 mm dia with necessary fittings complete as per specification no. FF-PP
140
-
-
Supplying and erecting G.I. pipe above ground of ‘C’ class ERW of size 50 mm dia with necessary fittings complete as per specification no. FF-PP
140
-
-
Supplying and erecting G.I. pipe above ground of ‘C’ class ERW of size 25 mm dia with necessary fittings complete as per specification no. FF-PP
350
-
-
Supplying & erecting cast iron double flange butterfly valve of size 200 mm dia. complete as per specification no. FF-VL/BFV
4
-
-
Supplying & erecting cast iron double flange butterfly valve of size 150 mm dia. complete as per specification no. FF-VL/BFV
4
-
-
Supplying & erecting cast iron double flange butterfly valve of size 100 mm dia. complete as per specification no. FF-VL/BFV
4
-
-
Supplying & erecting cast iron double flange butterfly valve of size 75/80 mm dia. complete as per specification no. FF-VL/BFV
5
-
-
Supplying & erecting cast iron double flange butterfly valve of size 50 mm dia. complete as per specification no. FF-VL/BFV
2
-
-
Supplying and erecting cast iron double flange ball type NRV of size 200 mm dia complete as per specification no. FF-VL/NRV
2
-
-
Supplying and erecting cast iron double flange ball type NRV of size 150 mm dia complete as per specification no. FF-VL/NRV
2
-
-
Supplying and erecting cast iron double flange ball type NRV of size 100 mm dia complete as per specification no. FF-VL/NRV
2
-
-
Supplying and erecting cast iron double flange ball type NRV of size 75/80 mm dia complete as per specification no. FF-VL/NRV
1
-
-
Supplying and erecting 200 mm dia Cast Iron end line strainer of Y-type
flanged end pattern, PN16 pressure rating, screen of SS end connection with
Flanged / Screwed / Socket Weld / Butt Weld End etc with standard OAR (open
area Ratio) for positive suction complete as per specification no. FF-VL/ELS
2
-
-
Supplying and installing pressure switch with 12/15 mm dia isolation valve, G.I. nipple, elbow, etc complete as per
specification no. FF-FFA/PS
1
-
-
INCOMING
160A, 50kA 4 Pole MCCB, Ics=100% Icu rating Digital Voltmeter 0-500V with selector switch Digital Ammeter (0-250 A) with selector swtich & CTs etc. LED type RYB phase indicating lamps, ON, OFF, trip indicating lamps Set of Copper Bus Bar 300A. OUTGOING
( Note : All outgoing feeders for pumps should have
digital Ammeter with selector switches, and LED type
ON, OFF, trip indicating lamps Main Fire Pump
125 A, 50kA TPN MCCB, Ics=100% Icu, with fully automatic Star/Delta starter for suitable HP of pump with overload protection, current sensing type single phase preventor complete with all acceessories and internal wiring required for automatic operation, selector switch for local/remote, auto/manual/OFF operation. Jockey Pump
63 A, 50kA TPN MCCB, Ics=100% Icu, with suitable
HP fully automatic Star/Delta starter with overload
protection, current sensing type single phase preventor
complete with all acceessories and internal wiring
required for automatic operation, selector switch for
local/remote, auto/manual/OFF operation. DIESEL ENGINE CONTROL
Control for diesel engine comprising Automatic/Manual
selctor switch & 3 attempts starting device, timers and relays as required, push buttons, start/stop in manual mode Indicating lamp for high/ Low Lub. Oil pressure, High Water Temp and Engine on indication Battery charger suitbale for 12V/24 V DC with boost and trickle selector switch, 0-30 V DC volt meter, and 020 A DC Ammeter, All standard relays and accessories for automatic operation of diesel engine System Controller
Designing, Supply, Installation, Testing and commissioning of system controller to control operation
of main electric fire pump, diesel pump, Pressurization
pump, Terrace pump in sequence as per specification
consisting of relays, timers. Sensors, annunciation
window for fault indication, complete as per
specification
1
-
-
Supplying and erecting one no. Brass orifice plate having 6 mm. thickness, 140 mm outer dia of 140 mm at every single outlet hydrant valve
7
-
-
Supplying and erecting gun metal double outlet hydrant valve fitted with necessary accessories complete as per specification no. FF-VL/HV
5
-
-
Supplying fire fighting reinforced rubber lined (R.R.L.) hose pipe, 63mm dia, 15m in length, fitted with necessary accessories complete as per specification no. FF-FFA/RRL
5
-
-
Supplying & erecting gun metal branch pipe of 63 mm dia fitted with 20 mm dia detachable hexagonal nozzle complete as per specification no. FF-FFA/NZ
5
-
-
Supplying and installing wall mounting swinging Hose reel drum fitted with 19 mm dia. 30m long high pressure polypropylene (Polyhose) fitted with necessary accessories complete as per specification no. FF-FFA/HV
5
-
-
Supplying and erecting M.S./CRCA cabinet for housing Floor Hydrant valve, hose pipe, hose reel and branch pipe (size 1000 x 736 x 736 mm.) made from 16 SWG sheet and angle iron 25 x 25 x 4 mm. having front doors with viewing glass (8"x6") and locking arrangement with necessary fixing material such as rubber bidding etc. duly painted in post box red colour.
5
-
-
Supplying and erecting 20/25mm dia gun metal air release cock, with necessary G.I. coupling to be fitted on top of air vessel or on wet riser complete as per specification no. FF-FFA/ARV
1
-
-
Supplying and erecting gun metal single outlet hydrant valve fitted with necessary accessories complete as per specification no. FF-VL/HV
5
-
-
Supplying and erecting M.S./CRCA cabinet for housing single hydrant valve (size 400 x 400 x 400mm.) made from 16 SWG sheet and angle iron 25 mm. x 25 mm. x 4 mm. having front doors with viewing glass (8"x6") and locking arrangement with necessary fixing material such as rubber bidding etc. duly painted in post box red colour
5
-
-
Supplying and erecting fire brigade header of 150 mm dia, for supplying water in fire tank complete as per specification no. FFFA/FBC
2
-
-
Supplying and erecting fire brigade header (Siamese connection) of 150 mm dia for supplying water to wet riser system complete as per specification no. FF-FFA/SMC
1
-
-
Supplying, erecting, testing and commissioning vane type water flow detector suitable for detecting flow of water in wet sprinkler pipe of main line or branch lines of 75/80 mm dia having following features 1) Visual switch activation 2) Rugged switch assembly 3) Heavy duty aluminium pipe saddles 4) Durable metal enclosure 5) Steel U bolts for secure mounting 6) Two SPDT ( Single pole double track ) synchronised switches 7) serviceable without draining pipes
1
-
-
Supplying, erecting, testing and commissioning of 15 mm (½") dia. NBCM Body chrome finished quartzoid bulb sprinkler having 68º C fixed temperature rating with deflector disc of conventional construction complete as per specification no. FF-SPR
164
-
-
Supplying, installing, testing and commissioning optical type smoke detector complete on box as per specification no. FFFAS/SD
65
-
-
Supplying, installing, testing and commissioning heat detector complete on box as per specification no. FF-FAS/HD
15
-
-
Supplying, installing, testing and commissioning manual call point (Pill box) with break glass push button in metal enclosure complete as per specification no. FF-FAAS/MCP
5
-
-
Supplying, erecting, testing and commissioning hooters having high (100dB @
1m) and low (94dB @ 1m) volume setting, group addressing facility allowing
multiple sounders to be activated with CRCA enclosure complete as per
specification no. FF-FAAS/HTR
5
-
-
Supplying, installation, testing and commissioning of micro processor based
intelligent addressable main fire alarm panel, central processing unit with the
4 loop capacity and capable of supporting upto 250 devices and detectors per
loop, with on-board LCD display with min 16 lines of text, operating at 230 V 50 HZ - AC with inbuilt Battery Backup of a minimum 24 hours in normal condition
and 30 min in alarm condition, suitable provision for network connectivity,
interfacing with third party equipment via a MODBUS/ OPC/ L-ON interface
etc. conforming to IS 15908:2021, ,IS 2189: 2008, EN 54 & VDS / FM/ UL 864
(10th edition) with 3 years replacement warranty FF-AFAS/CP.
1
-
-
Supplying, erecting, testing and commissioning of 2 core shielded cable
complete as per specification no. FF-PA/MCC 1.5 sqmm
500
-
-
Providing coating of bitumen paint & 4mm thick wrapping for underground 150 mm ring main of fire fighting system.
100
-
-
Evaluation Notes How It Works ?