Goa State Urban Development Agency Tender

View complete overview of Goa GSUDA Tender

Goa State Urban Development Agency - GSUDA Tender

Works
Civil And Construction
Building Construction
Eprocure
Opening Date18 Jan 2025
Closing Date20 Feb 2025
Tender Amount₹ 7,59,73,441 
Notes
Download

Costs

  • EMD

    ₹ 15,19,470
  • Document Cost

    ₹ 20,000
  • Tender Fee

    ₹ 6,000

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
Earthwork in excavation over areas by mechanical/mannual means in all type of strata comprising any of the materials such as soil, silt, sand, clay, gravels, moorum of all varieties, shingles, pebbles, all types of conglomerates, all type of laterite rock, soft rock, disintergrated rock, fissured/ shattered/ decomposed rock or weathered rock and all such other materials as described under appendix to these specifications whether in full or in parts as the case may be adopting any approved method or methods as may be convenient or permitted inclusive of chiselling, wedging etc. in all conditions such as dry, moist, saturated, submerged, foul, saturated, submerged etc. as directed by engineer in charge etc. including dressing of sides, ramming of bottom including all leads and lifts including getting out the excavated material as directed including pumping or bailing out water, barricading, danger lighting, guarding as directed by Engineer in charge: All kinds of soil

2340

-

-

... More
Earthwork in excavation by mechanical means (hydraulic excavator)/manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sq.m on plan) including disposal of excavated earth lead upto 50 m and lift upto 1.5m disposed earth to be leveled and neatly dressed including providing barricading, danger lighting guarding as directed in :All kinds of soil

50

-

-

... More
Earthwork in excavation by mechanical means (hydraulic excavator)/manual means in foundation pipeline trenches drain (not exceeding 1.5 m in width or 10 sq.m. on plan) including dressing of sides and ramming of bottoms, lift upto 1.5 m including getting out the excavated soil and disposal of surplus excavated soil as directed within a lead of 50 m: All kinds of soil

36.86

-

-

... More
Refilling the pipeline/foundation trenches plinth sides, foundation etc. with available excavated earth in layers not exceeding 20 cm depth consolidating each layer ramming and watering lead upto 50 M and all lifts and disposal of surplus earth as directed by Engineer in Charge.

970.74

-

-

... More
Supplying and filling in plinth under floors, trenches including watering ramming consolidating, dressing, complete.b)Moorum

1457

-

-

... More
Rubble packing with hard laterite stone under floors including watering ramming and consolidating etc. in pipeline trenches and other foundations complete.

166

-

-

... More
Providing anti – termite treatment to buildings conforming to I.S.S. 6113 part II 1971 (revised) including adopting precautions for health hazards and safety measures as required therein with the cost of all materials, chemicals, plants, equipments required for the treatment and furnishing a guarantee for a minimum period of 10 years from the date of completion including eradicating any infestation of termite free of cost during the guaranty period complete. (The payment will be made on plinth of the building. a) Pre-construction

1082

-

-

... More
Disposal of surplus earth & debris by mechanical transport including loading, unloading and stacking upto 20 KM leads, The site should be identified by the contractor and obtain all statuatory approval.

1369.26

-

-

... More
Providing and laying in position cement concrete 1:2:4 (1 cement : 2 coarse sand: 4 graded granitic or basaltic stone aggregate 40 m nominal size) excluding cost of centering, shuttering and finishing :a)All works upto plinth level

47

-

-

... More
Providing and laying in position ready mixed concrete (RMC) manufactured in fully automatic batching plant and transported to site of work in transit mixer for a lead upto 10kms having continious agitated mixer, manufactured as per mix design of specified grade for reinforced cement concrete work including pumping of R.M.C., from the transit mixer to the site of laying, excluding the cost of centering, shuttering, finishing and reinforcement including the cost of admixtures in recommended porportions as per IS : 9103 to accelerate/retard setting of concrete, improve workability without imparing strength and durability as per the directions of the engineer-in-charge. All works upto floor V level: M-30 grade of concrete

785

-

-

... More
Providing and laying upto floor five level cement concrete 1:2:4 (1 cement: 2 coarse sand: 4 graded granitic or basaltic stone aggregate 20 mm nominal size) including smooth finishing to exposed surfaces, with cement mortar 1:3 (1 cement: 3 fine sand) including centering and shuttering etc: String courses, copings, bedplates, anchor blocks, plain window sills and the like.

2

-

-

... More
Providing and laying upto floor five level cement concrete 1:2:4 (1 cement: 2 coarse sand: 4 graded granitic or basaltic stone aggregate 20 mm nominal size) including smooth finishing to exposed surfaces, with cement mortar 1:3 (1 cement: 3 fine sand) including centering and shuttering etc: Small lintels not exceeding 1.5 m clear span, including coping and the like requiring form work to the suspended portions.

1

-

-

... More
Providing and laying in position (1:2:4) reinforced cement concrete excluding the cost of centering, shuttering, finishing and reinforcement. (1 cement:2 coarse sand:4 graded stone agg 20mm nominal size):In beams, suspended floors, roofs having slope upto 15° landings, balconies, shelves, chajjas, intels, bands, plain window sills, staircases upto floor five level

4

-

-

... More
Providing corrosion resistant steel CRS-50 bars of (SAIL, TATA, VIZAG, JSW Steel Ltd.)(Confirming to IS 1786 if 1985) for RCC work including bending, binding & placing in position in all the floors along with factory made precaste concrete cover blocks of specified s izes whose compressive strengthis not less than that of surrounding concrete in the structural member .

170448.53

-

-

... More
Centering & shuttering including Strutting, Propping & removal of forms for :Foundations, Footings, Bases for columns

258

-

-

... More
Centering & shuttering including Strutting, Propping & removal of forms for :Vertical surfaces such as retaing walls, return walls, Partitions, walls (any thickness) including attached Pilasters, Buttresses, Plinth and string courses, Fillets and the like

868

-

-

... More
Centering & shuttering including Strutting, Propping & removal of forms for :Columns, Piers, Pillars, Aburments, Posts and struts (square rectangle polygon in plan)

499

-

-

... More
Centering & shuttering including Strutting, Propping & removal of forms for :Sides and Soffits of beams, Beam Haunchings, Cantilever, Girders, Bressumers and Lintels plinth beams not exceeding 1m in depth

1333

-

-

... More
Centering & shuttering including Strutting, Propping & removal of forms for :Staircases (except spiral staircases) excluding landing

95

-

-

... More
Centering & shuttering including Strutting, Propping & removal of forms for :Suspended floors, roofs landings, shelves & their supports

1323

-

-

... More
Centering & shuttering including Strutting, Propping & removal of forms for :Extra to be added for additional height in centering, shuttering where ever required with adequate bracing, propping etc. including cost of de- shuttering and de-centering at all levels, over a height of 3.5m, for every additional height of 1m or part thereof. (Plan area to be measured) Suspended floors, roofs, landings, beams and balconies (plan area to be measured)

243.38

-

-

... More
Pre-cast cement concrete solid block masonry of compressive strength 70 kg / cm2 in cement mortar 1:4 (1 cement : 4 corase sand ) in superstructure size of blocks (30 x 23 x 15) floor V level

269

-

-

... More
Pre-cast cement concrete solid blocks masonry of compressive strength 70 kg / cm2 in cement mortar 1:4 (1 cement : 4 corase sand ) in partition walls size of blocks (30 x 20 x 10)

38

-

-

... More
Providing and fixing chicken mesh of 22 gauge, with about 30 cm. width at the junction of R.C.C members and brick work, of approved quality including fixing mesh in position by necessary drilling in concrete / B.B.masonry and or tying by binding wire etc. complete.

301

-

-

... More
Providing and fixing 150 mm. bright finished brass floor door stopper with rubber cushion screws etc. to suit shutter thickness complete.

22

-

-

... More
Providing and fixing brass hydraulic door closer of make Everest universal 68 or equivalent with necessary screws and fittings complete.

22

-

-

... More
Providing and fixing anodised aluminium mortice lock knob type handle (without lock)

15

-

-

... More
Providing and fixing aluminium handle anodised or dyed to required colour or shade with screws etc. complete:125 mm

13

-

-

... More
UPVC ONLY DOOR FRAME:- Providing & fixing Upvc Door Frame Yashashri make or equivalent made out of Upvc extruded multi cavity frame of 60 mm x 60mm x 2mm wall thickness. Frame is reinforced with G.I. Channel & welded in corners with Average weight 0.80 kg per running mtr. These frames are tested by using BS 2782 & DIN 53459 test methods.

77

-

-

... More
32 MM DOOR SHUTTER:- Providing & fixing 32mm door shutter Yashashri make or equivalent, made by using 31mm x 150 mm x 1.5mm upvc multi-cavity section havingn Toung & Groove jointing method and boarder having 35mm x 30mm x multi- cavity section. The corners are joined by inserting polymetric corners & hardware used for fixing the door shutter is stainless steel hinges & S. S. handle & S.S. tower bolt. The average weight of 32mm door shutter is 6.30 kg per sq mtr. These Upvc sections are tested by using BS 2782 & DIN 53459 test methods.

28

-

-

... More
TWO TRACK SLIDING WINDOW (Heavy):- Providing & fixing Two Track sliding window Yashashri make or equivalent, in heavy sections made out of 104mm x 51 mm x 2.5 mm Upvc multi cavity track section & shutter made out of 45mm x54mm x 2.5mm Upvc multi cavity section welded in corners with Glass beading & EPDM Gasket & 4mm clear glass with lock & rollers. The average weight of Two Track Sliding window (Heavy) is 16.75 kg per sq mtr. These Upvc sections are tested by using BS 2782 & DIN 53459 test methods.

86

-

-

... More
Providing and fixing in position S.S. hand rail in main stair case, and landing as per approved design shown in the drawing including bending handrail pipe to proper shape in curves with specials, etc. complete.

105

-

-

... More
Providing and fixing 12 mm thick frameless toughened glass door shutter of approved brand and manufacture, including providing and fixing top & bottom pivot & spring type fixing arrangement and making necessary holes etc. for fixing required door fittings, all complete as per direction of Engineer (Door handle, lock and stopper etc.to be paid separately)

85

-

-

... More
Providing and fixing stainless steel (Grade 304) railing made of Hollow tubes, channels, plates etc.with hairline finish, including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners, stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer, ( for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.).

695

-

-

... More
Design, supply & installation of suspended Spider Glazing system (Frameless glass structural glazing) designed to withstand the wind pressure as pr IS 875 (Part-III). The Suspended System held with Spider Fittings of SS-316 Grade Steel of approved manufacturer with glass panel having 12 mm thick clear toughened glass held together with SS- 316 Grade Stainless steel Spider & bolt assembly with laminated glass fins 21mm thick. The Glass fins and glass panel assembly shall be connected to Slab/beams by means of SS- 316 Grade stainless steel brackets & Anchor bolts and at the bottom using SS channel of 50x25x2mm using fastener & anchor bolts, non staining weather sealants of approved make, Teflon/ nylon bushes and separators to prevent bi-metallic contacts, all complete to perform as per specification and approved drawings. The complete system to be designed to accommodate thermal expansion & seismic movements etc. The joints between glass panels (6 to 8 mm) and gaps at the perimeter & in U channel of the assembly to be filled with non staining weather sealant, so as to make the entire system fully water proof & dust proof. The rate shall include all design, Engineering and shop drawing including approval from structural designer, labour, T&P, scaffolding , other incidental charges including wastage, enabling temporary services all fitting fixers nut bolts, washer, Buffer plates, fastener, anchors, SS channel laminated glass etc. all complete. For the purpose of payment, actual elevation area of Glazing including thickness of joints and the portion of Glass panel inside the SS channel shall be measured.

89.14

-

-

... More
Kotah stone slab flooring over 30 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid over & jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing & polishing complete a)25 mm thick.

381

-

-

... More
Providing 20mm thick marble slab to urinal partitions wlyh cement etc. complete

2

-

-

... More
Providing and fixing 1st quality ceramic glazed wall tiles (Johnson, Somany, Kajaria )conforming to IS:15622 (thickness to be specified by the manufacture of approved make in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in-charge in skirting, risers of steps and dados over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand ) and jointing with grey cement slurry @3.3kg per sq.m including pointing in white cement mixed with pigment of matching shade complete: Wall Ceramic Glazed Tiles : 300 x 600 (Basic rate 400/sqm).

217

-

-

... More
Providing and and laying antiskid floor tiles 12 x 12 upto 16 x 16 in of Johnson, Somany, Kajaria (thickness to be specified by the manufacturer) of 1st quality conforming to IS:15622 of approved make in shades as specified laid on 20 mm thick cement mortar 1:4 (1 Cement : 4 Coarse sand) including pointing the joints with white cement and matching pigment etc., complete a)Dark Shades, Basic rate 410/sqm.

38.68

-

-

... More
Providing and and laying vitrified floor tiles in different sizes of Johnson, Somany, Kajaria (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS:15622 of approved make in colours and shades as specified laid on 20 mm thick cement mortar 1:4 (1 Cement : 4 Coarse sand) including grouting the joints with white cement and matching pigment etc., complete 900 x900 mm Light shades, Basic rate 636/sqm.

903

-

-

... More
Providing and and laying vitrified unglazed porcelain tactile floor tiles in different sizes of Johnson, Somany, Kajaria (thickness to be specified by the manufacturer) and conforming to IS:15622 of approved make in colours and shades as specified laid on 20 mm thick cement mortar 1:4 (1 Cement : 4 Coarse sand) including grouting the joints with white cement and matching pigment etc., complete: 300 x 300 mm designe-liner, Basic rate 440/sqm.

6.89

-

-

... More
Providing and laying factory made Shot blasted cement concrete interlocking paver block of minimum M35 grade made by heavy duty block making machine with strong vibratory compaction and of aprpoved size and design / shape laid in 50 mm thick compacted bed of coarse sand, filling the joints with coarse sand, etc. all complete as per the direction of Engineer.- in I, Wave, Rectangular, Square etc. shapes. The products should comply to IS 15658:2006 and manfucatured by ISO9001: 2008 certified plant. The shot blasting should be done using 0.4-0.5mm dia steel shots with a speed of 3200 rpm. a)60 mm thick in all colours except grey

58.4

-

-

... More
Providing and laying factory made Shot blasted cement concrete interlocking paver block of minimum M35 grade made by heavy duty block making machine with strong vibratory compaction and of aprpoved size and design / shape laid in 50 mm thick compacted bed of coarse sand, filling the joints with coarse sand, etc. all complete as per the direction of Engineer.- in I, Wave, Rectangular, Square etc. shapes. The products should comply to IS 15658:2006 and manfucatured by ISO9001: 2008 certified plant. The shot blasting should be done using 0.4-0.5mm dia steel shots with a speed of 3200 rpm: 60mm thick with Grey colour

233.6

-

-

... More
Vaccum dewatering of laid concrete for roads/ areas using Tremix machinery including formwork with MS channel/ angle sections on sides of concrete with proper supporting system, surface/screed & needle vibrating & levelling of concrete. Vaccum dewatering should be done using suction mats (spread on surface) & suction pump, power floating/ troweling using screen floater, manual spreading of hardening compound (if any), smooth/rough/broom finish to the required slope, camber & level, groove cutting (upto 10mm wide x50mm deep) for contraction/expansion, construction & longitudinal hoints, Providing dowel bars with sleeve/tie bars, filling two component polysuphide sealant/joint filler (Bitumen hot sealing compound: Grade A), taping with masking tape etc complete. (Concrete, reinforcement, Dowel Bar with sleeve/tie bar Reinforcement, tarpaulin sheet to be paid separately)

13.83

-

-

... More
Providing and laying flamed finish Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing, curing and polishing etc. all complete as specified and as directed by the Engineer : Flamed finish granite stone slab. a)Jet Black.

182

-

-

... More
Providing and fixing 18 mm thick Granite of any colour and Shade gang saw cut, mirror polished, premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills, facias and similar locations of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 (1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing, moulding and polishing to edges to give high gloss finish etc. complete at all levels. Granite of any colour and shade, area of slab over 0.50 sqm a)Jet Black

49

-

-

... More
Extra for providing opening of required size & shape for wash basin/ kitchen sink in kitchen platform, vanity counter and similar location in marble/ Granite/ Cuddapah stone work, including necessary holes for pillar taps etc. including moulding, rubbing and polishing of cut edges etc. complete.

8

-

-

... More
Providing and laying integral cement based treatment (Box type) for water proofing on horizontal surface at all depth below ground level for under ground structures as directed by Engineer and consisting of : i) Ist layer of 20 mm to 25 mm thick approved and specified rough stone slab over a 25 mm thick base of cement mortar 1:3 (1 cement : 3 coarse sand) mixed with water proofing compound conforming to IS:2645 in the recommended proportion over the leveling course (leveling course to be paid separately). Joints sealed and grouted with cement slurry mixed with water proofing compound. ii) 2nd layer of 25 mm thick cement mortar 1:3 (1 cement: 3 coarse sand) mixed with water proofing compound in recommended proportions. iii) Finishing top with stone aggregate of 10 mm to 12 mm nominal size spreading @ 8 cudm/sqm thoroughly embedded in the 2nd layer using rough Shahbad/Kotah stone

121.32

-

-

... More
Providing and laying integral cement based treatment (Box type) for water proofing on the vertical surface by fixing specified stone slab 20 mm to 25 mm thick with cement slurry mixed with water proofing compound conforming to IS:2645 in recommended proportions with a gap of 20 mm (minimum) between stone slabs and the receiving surfaces and filling the gaps with neat cement slurry mixed with water proofing compound and finishing the exterior of stone slab with cement mortar 1:3 (1 cement : 3 coarse sand) 20 mm thick with neat cement punning mixed with water proofing compound in recommended proportion complete at all levels and as directed by Engineer using rough

281.38

-

-

... More
Waterproofing of sunken slabs, toilet blocks, terraces on slabs under brickbats, roofs, watertanks. Cleaning the surface and filling cracks (if any), applying EPCO ACR wherever necessary, Providing and Moistening the surface with water to render it saturated. Mix Cement and Monobond WF in the ratio of 1.25 kg to 1 by weight and stir continuously. Apply minimum 2 coats with an interval of 12 hours minimum between the coats. Fix fiber mesh while the first coat is still tacky. Cure with sprinkling of water 3-4 times a day. incl. cost of scaffolding transport etc. as per dir of EIC. All the chemicals will be of Krishna Conchem Products Pvt. Ltd. or Equivalent

660

-

-

... More
Providing and fixing GI Clip in Metal Ceiling System of 600x600 mm module which includes providing and fixing 'C' wall angle of size 20x30x20 mm made of 0.5 mm thick pre painted steel along the perimeter of the room with help of nylon sleeves and wooden screws at 300 mm center to centre, suspending the main C carrier of size 10x38x10 mm made of G.I steel 0.7 mm thick from the soffit with help of soffit cleat 37x27x25x1.6 mm, rawl plugs of size 38x12 mm and C carrier suspension clip and main carrier bracket at 1000 mm c/c. Inverted triangle shaped Spring Tee having height of 24 mm and width of 34 mm made of GI steel 0.45 mm thick is then fixed to the main C carrier and in direction perpendicular to it at 600 mm centers with help of suspension brackets. Wherever the main C carrier and spring T have to join, C carrier and spring T connectors have to be used. All sections to be galvanized @ 120 gms/sqm (both side inclusive), fixing with clip in tiles into spring 'T' with : b) GI Metal Ceiling Clip in plain Beveled edge global white colour tiles of size 600x600 and 0.4- 0.5 mm thick with 25 mm height, made of G I sheet having galvanizing of 100 gms/ sqm (both sides inclusive) and 20% perforation area with 1.8 mm dia holes and having NRC of 0.5, electro statically polyester powder coated of thickness 60 microns (minimum), including factory painted after bending and perforation.

40.61

-

-

... More
Providing & fixing False Ceiling Yashashri make or equivalent, made out of 2” x 1” M.S sq tube frame support structure & 20mm x 155mm x 1.2mm multi-cavity upvc section, 30mm x 40mm x 2mm Upvc multi-cavity section with hidden screwing system. The average weight of False Ceiling is 8.50 kg per sq mtr. These Upvc sections are tested by using BS 2782 & DIN 53459 test methods.

525.2

-

-

... More
12mm cement plaster 1:4 (1 cement : 4 coarse sand)

1686.72

-

-

... More
6mm cement plaster to ceiling 1: 3 (1 cement : 3 fine sand)

946.78

-

-

... More
18mm cement plaster in two coats under layer 12mm thick cement plaster 1:5 ( 1 cement : 5 coarse sand) and top layer 6mm thick with cement plaster 1: 3 (1 cement : 3 coarse sand) finished with sponge

2164.01

-

-

... More
Extra for plastering exterior walls of height more than 10m from ground level for every additional height of 3m or part thereof: a)10 M TO 13 M hight( Third Floor)

59.16

-

-

... More
Extra for plastering exterior walls of height more than 10m from ground level for every additional height of 3m or part thereof: b)13 M TO 16 M hight (Fourth Floor)

283.61

-

-

... More
Extra for plastering exterior walls of height more than 10m from ground level for every additional height of 3m or part thereof: c)16 M TO 19 M hight (Terrace 01)

259.87

-

-

... More
Extra for plastering exterior walls of height more than 10m from ground level for every additional height of 3m or part thereof: d)19 M TO 22 M hight (Terrace 02)

134.6

-

-

... More
Extra for plastering exterior walls of height more than 10m from ground level for every additional height of 3m or part thereof: e)22 M TO 25 M hight (Terrace 02)

104.27

-

-

... More
Extra for providing and mixing water proofing material proportion recommended by the manufacturers. e)20mm cement plaster 1: 3 (1 cement : 3 sand)

2164.01

-

-

... More
Providing and applying white cement based putty of average thickness 1.00mm of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete.

1686.72

-

-

... More
Wall painting (two or more coats) with plastic emulsion paint of approved brand and manufacture on new work to give an even shade.

2633.51

-

-

... More
Painting three or more coats with acryllic exterior paint of approved brand and manufacture (such as weather shield,APEX) including applying one coat of cement primer and one coat of surface treatment etc. complete.

2272.21

-

-

... More
Supplying and fixing Pre-cast cement concrete kerb-stones(factory made,the factory should be ISO certified and registered under Dirctorate of Industries, Govt. of India) of M-20 with 20 mm nominal size granitic/basaltic aggregate properly consolidated by mechanical plat-form and vibrators with smooth finish including fixing at site complete as per specification. d)Size 60 cm L x30 cm H x 10cm T

20.68

-

-

... More
Providing & fixing site barricading all around the site including G.I. Sheet & Steel work in built up tubular (round, square or rectangular hollow tubes etc.) (Square Hollow Section (SHS) IS4923 /Rectangular Hollow Section (RHS) IS4923/ Circular Hollow Section (CHS) IS1161 closed Structural Steel of approved make (Min Yeild Stress 310 Mpa)) trusses etc., including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete.

226

-

-

... More
Supplying and fixing high pressure decorative laminates (HPL)of 6mm thickness according to the European Standard EN 438 and to ISO 4586. These systems require 50x25mm rectangular aluminum channel, 10x30 size SS screw, PU sealant, VHB structural glazing tape, PU primer black etc.

337.36

-

-

... More
Supply of fully insulated wooden fire door of 120min. fire rating, of maximum 52mm thickness, comprising of 75mm x 44mm hardwood internal timber frame work, with infill insulation of 20mm thick of of 48 kg/m3, wool insulation, coated with viper intumuscent coating on both sides for insulation. The coated insulation shall be sandwiched between min 12mm thick Non Combustible (Calcium Silicate) Boards on both sides (edge to edge on internal Hardwood frame) and cladded with 3mm Thick Commercial Ply & 1mm Thick Laminate (Any Regular Plain Shade In Suede Finish) on both faces, with 52mm x 10mm exposed hard wood lipping all round the shutter the main door frame will be made out of Hard Wood (Red Mirandi) of section 120 x 70mm and coated with viper Fire retardent Primer and paint. The rebate shall be of 20mm x 55 mm in Door Frame to accommodate the shutter in frame.The frame shall be fitted with fire & smoke intumescent seal of size 20 x 4mm on frame & shutter . The pasting of the ply / laminate should be done using automatic machine and should be free from any nails or perforations. The manufacturer should be compliant to ISO 9001: 2008 and CE certified, manufacturer should be covered under IGBC scheme. Approved manufacturer Navair International Ltd or quivalent subject to architect’s approval. And should be ISO Certified company. All Including : Single rebated Hard Wood (Red Mirandi) frame of section 120x70mm finished with prime and paint. 52mm thick wooden shutter faced with 3mm thick Commercial ply & 1mm thick Laminate (Any Regular Plain Shade In Suede Finish) on both face. SS Ball Bearing Hinges Of Size 100x75x3mm Of GEZE Make-04 Nos. Per Leaf.Triple point locking panic bar with external trim GEZE make-01 No. Per Door. Overhead Door Closer TS-1000C Of GEZE Make-01 No. Per Leaf. Vision Panel Of Size 300x300mm (Fitted With 5 mm Thick 120 Min. Fire Rated Clear Glass Of SAINTGOBAIN Make)-01 No. Per Leaf. HRD The board shall be Resistant to vermin, mould growth, minor impact, abrasion and short term water attack and shall be Off –white in colour with a smooth surface suitable to receive most forms of decoration having following technical characters i.e.; The Construction design similar to NWD12050 and similar to the design tested as per BS 476 part 22 and IS 3614 Part II, at CBRI, India. The shutter can be provided with appropriate openings for view panel glass. Prototype Test certificate for fire rating of doors from CBRI, Roorkee for earlier tested design shall be attached along with manufacturers test certificate

8

-

-

... More
Providing supply and installation SS 304 grade Buff finish with clear toughened glass of height 1200mm. grouted in floor with U channel and top rail of SS 304 grade 50mm diameter mounted on glass and secured on both ends in concrete complete without baluster gap between each glass panel of 10mm minimum. Ledge wall required to your scope, maximum width without support 3mts.

112.71

-

-

... More
Providing and fixing signage made of base material made of 6mm thick transparent/coloured acrylic sheet. The Graphic is of computer cut self adhesive vinyl covered with clear vinyl to protect from peeling. The signage shall be fixed with 12mm dia SS studs or ss mirror screw

6

-

-

... More
Supplying and Installation Z -Sheet pile 650 X420X10 MM max length 9 mtr, min weight 85.5 kg/m section modules not less than 1880 cm3/m ,Moment of inertia shall not be less than 37580 cm4/m , Profile length and height tolerance should be between +30,-10mm, web thickness tolerance +0.08 &-0.10mm, Material grade comprising to IS2062 E-250. complete with welding bolting and neseccery struts including digging by rotatry method and fixing in postition complete as requirted and as asked by the engineer incharge.

102

-

-

... More
Proving and fixing white vitreous china Wall Hung type (European Type) water closet with seat and lid with C.I. brass hinges and rubber fittings with flush valve nelson/ similar fully chromium plated with stop cock, wall flanges, flush pipe or elbow and vaccum breaker coupling etc. including chair bracket/rag bolts, cutting & making good the walls and floors where required and concealed seat support - W.C. Pan with white plastic seat and lid

8

-

-

... More
Providing and fixing vitreous china wash basin with RS or C.I. brackets painted white, 15 mm C.P. brass pillar taps C.P. brass chain with rubber plug 32 mm C.P. brass waste of pattern, 32 mm diameter M.I. or C.P. brass trap and union complete, including cutting and making good the walls where required:'Flat back wash basin size 630 x 450mm with a pair of 15 mm C.P. brass pillar taps.

12

-

-

... More
Providing and fixing white vitreous china flat back or wall corner type lipped front urinal basin of 430 x 260 x 350 mm and 340 x 430 x 265 mm sizes respectively with pvc automatic flushing cistern with fittings, R.S. or C.I. brackets, standard size galvanised steel flush pipe and spreaders with brass unions & G.I. clamps complete, including painting of cister and fittings, cutting and making good the walls and floors where required:One urinal basin with 5 litres p .v .c. automatic flushing cistern.

8

-

-

... More
Providing and fixing NICKEL chrome plated copper alloy Fancy Two Way Bib Cock with single knob and wall flange conforming to IS 8931:1993 15mm nominal bore.

8

-

-

... More
Providing and fixing Hand Shower (Health Faucet) with 8mm dia, ABS/brass body with double lock 1.00m long Flexible tube (Brass plated stainles steel flexible hose) and wall hook of approved quality confirming to IS standards

8

-

-

... More
Providing and fixing NICKEL chrome plated copper alloy Fancy concealed stop cock with slinding flance 15 mm Jaquar make or equivalent. Confirming to IS 8931;1993 a)15mm nominal bore

28

-

-

... More
Providing and fixing NICKEL chrome plated copper alloy Fancy long body bib cock with wall flance Jaquar make or equivalent. Confirming to IS 8931;1993 a)15mm nominal bore

4

-

-

... More
Providing & fixing bevelled edge mirror of superior glass (5mm thk) of approved Quality, shape & size complete with CP brass screws and washers, Cleats, CP studs etc Complete.

11.76

-

-

... More
Providing & fixing soap dish chromium plated with brackets fixed to wooden cleats with CP brass screw

8

-

-

... More
Providing and fixing toilet paper holder :C.P. brass

8

-

-

... More
Providing & fixing c.p. brass towel rail complete with C.P. brass brackets fixed to wooden cleats with C. P. brass screws:600 x 20 mm size

8

-

-

... More
Providing & fixing (4’) 100 mm sand cast iron grating for gully floor or nahni trap.

12

-

-

... More
Providing and fixing chlorinated ployvinyl chloride (CPVC) pipes confirming to IS:15778, having thermal stability for hot and cold water supply including all CPVC plain and brass threaded fittings including fixing the pipes with clamps at 1 mt. spacing. This includes jointing of pipes and fittings with one step CPVC solvent cement and testing of joints complete as per direction of the Engineer-in-charge. Concealed work (medium duty SDR 13.5 pipe) including cutting chases and making good the walls etc:20 mm dia nominal outer dia pipes.

40

-

-

... More
Providing and fixing chlorinated ployvinyl chloride (CPVC) pipes confirming to IS:15778, having thermal stability for hot and cold water supply including all CPVC plain and brass threaded fittings including fixing the pipes with clamps at 1 mt. spacing. This includes jointing of pipes and fittings with one step CPVC solvent cement and testing of joints complete as per direction of the Engineer-in-charge. Concealed work (medium duty SDR 13.5 pipe) including cutting chases and making good the walls etc:25 mm dia nominal outer dia pipes.

71.32

-

-

... More
Providing and fixing chlorinated ployvinyl chloride (CPVC) pipes confirming to IS:15778, having thermal stability for hot and cold water supply including all CPVC plain and brass threaded fittings including fixing the pipes with clamps at 1 mt. spacing. This includes jointing of pipes and fittings with one step CPVC solvent cement and testing of joints complete as per direction of the Engineer-in-charge. Concealed work (medium duty SDR 13.5 pipe) including cutting chases and making good the walls etc:32 mm dia nominal outer dia pipes.

39.76

-

-

... More
Providing and fixing chlorinated polyvinyl chloride (CPVC) pipes confirming to IS: 15778 having thermal stability for hot and cold water supply includng all CPVC plain and brass threaded fittings CPVC solvent cement, trenching, refilling and testing of joints complete as per firectionof the Engineer in charge.(External work (heavy duty SDR 11 pipe)40 mm dia nomianl outer dia pipes.

25

-

-

... More
Providing and fixing chlorinated polyvinyl chloride (CPVC) pipes confirming to IS: 15778 having thermal stability for hot and cold water supply includng all CPVC plain and brass threaded fittings CPVC solvent cement, trenching, refilling and testing of joints complete as per firectionof the Engineer in charge.(External work (heavy duty SDR 11 pipe)50 mm dia nominal outer dia pipes.

15

-

-

... More
Providing and fixing 3 layer PP-R (Polypropylene Random copolymer) pipes SDR 7.4 UV stabilized & anti-microbialfusion welded, having thermal stability for hot & cold water supply including all PP-R plain & brass threaded polypropylene random fittings i/c trenching, refilling & testing of joints complete as per direction of Engineer in charge. (External work): 63 mm dia nominal outer dia pipes.

55.82

-

-

... More
Providing & fixing G.I. pipes complete with G.I. fittings including trenching & re-filling etc. (external work).50 mm nominal bore

20

-

-

... More
Providing and fixing non-return valve of approved quality :32 mm nominal bore

6

-

-

... More
Providing and fixing ball valve (brass) of approved quality. High pressure with P.V.C. floats :25 mm nominal bore

8

-

-

... More
Providing and fixing brass full way valve (heavy) duty with wheel of approved quality :32 mm nominal outer dia Pipes

3

-

-

... More
Providing and fixing brass full way valve (heavy) duty with wheel of approved quality :40 mm nominal outer dia Pipes

4

-

-

... More
Providing and fixing brass full way valve (heavy) duty with wheel of approved quality :50 mm nominal outer dia Pipes

5

-

-

... More
Providing and fixing brass full way valve (heavy) duty with wheel of approved quality :65 mm nominal outer dia Pipes

5

-

-

... More
Providing and placing on terrace roof of floor two (1st floor roof single piece rotational moulded polythene water storage tank having I S I mark and conforming to I S 12701; 1996: 1000 lit. capacity

5

-

-

... More
Extra for placing polythene tank on roof of floor three.For third floor (2nd floor roof)1000 lit. capacity

15

-

-

... More
Fixing water meter & stop cock in G. I. Pipe line including cutting & treading the pipe and making long screw etc. complete (cost of water meter and stop cock to be paid separately)

1

-

-

... More
Providing and fixing rigid PVC bend of required degree (of approved make) for S.W.R. drainage pipes of approved including lubricating.110 mm dia

18

-

-

... More
Providing and fixing single tee of rigid PVC (approved make) for S.W.R. pipes including lubricating etc. complete, without door:110 mm dia.

17

-

-

... More
Providing and fixing single Tee of rigid PVC (approved make ) for S.W.R. pipes including lubricating etc complete, with door :110 mm dia

4

-

-

... More
Providing and fixing rigid PVC S.W.R. (soil, waste & rain water drainage pipes of approved including lubricant etc. complete (single/double) socketed:Single socketed pipe 110 mm dia

116.96

-

-

... More
Providing and fixing nahani trap of rigid PVC (approved make ) for S.W.R. pipes including lubricating etc complete, without door : a)110 mm dia

12

-

-

... More
Providing and fixing NICKEL chrome plated copper alloy Fancy BOTTLE TRAP ECONOMY TYPE 32MM Jaquar make or equivalent. Confirming to IS 8931;1993

12

-

-

... More
Providing and fixing square-mouth S.W. gully trap grade ‘A’ complete with c.i. grating brick masonry chamber and water tight C.I. cover with frame of 300 x 300 mm size (inside the weight of cover to be not less than 4.53 kg). And frame to be not less than 2.72 kg as per standard design : b)100 x 150 mm size P or S type

1

-

-

... More
Making khurras 45 x 45cm with average minimum thickness of 5cm of cement concrete 1:2:4 (1 cement: 2 coarse sand : 4 stone aggregate of 20mm nominal gauge) finished with 12mm cement plaster 1: 3 (1 cement: 3 coarse sand) & a coat of neat cement rounding the edges and making and finishing the outlet complete.

8

-

-

... More
Providing and fixing U.P.V.C. pipe clips (approved make ) for S.W.R. pipes :110 mm dia

50

-

-

... More
Providing and fixing R.P.V.C. vent cowl:110 mm dia

2

-

-

... More
Making connection of drain or sewer line with existing manholes including braking into and making good the walls, floors with cement concrete 1:2:4 mix (1 cement : 2 coarse sand: 4 graded stone aggregate 20 mm nominal size) cement plastered on both sides with cement mortar 1:3 (1 cement : 3 coarse sand) finished with a floating coat of neat cement and making necessary channels for the drain etc. complete: a) For pipe 100 to 150 mm dia

2

-

-

... More
Constructing brick masonry manhole or inspection chamber with second class bricks in cement mortar 1:5 (1 cement :5 fine sand) R.C.C. top slab with 1:2:4 mix (1 cement: 2 coarse sand ;4 graded stone aggregate 20mm nominal size foundation concrete 1:2:4 mix (1 cement ;2 coarse sand :4 graded stone agrregate 40mm nominal size) inside plastering 12 mm thick with cement mortar 1:3 (1 cement :3 coarse sand) finished with a floating coat of neat cemetn and making channels in cement concrete 1:2:4 mix (1 cement :2 coarse sand :4 graded stone aggregate 20 mm nominal size) neatly finished complete as per standard design: Inside size 90 x80 cm and 60 cm deep including C.I. cover with frame (light duty) 455 x 610 mm internal dimensions total weight of cover and frame to be not less than 38 kg. (weight of cover 23 kg.)

3

-

-

... More
Constructing brick masonry manhole or inspection chamber with second class bricks in cement mortar 1:5 (1 cement :5 fine sand) R.C.C. top slab with 1:2:4 mix (1 cement: 2 coarse sand ;4 graded stone aggregate 20mm nominal size foundation concrete 1:2:4 mix (1 cement ;2 coarse sand :4 graded stone agrregate 40mm nominal size) inside plastering 12 mm thick with cement mortar 1:3 (1 cement :3 coarse sand) finished with a floating coat of neat cemetn and making channels in cement concrete 1:2:4 mix (1 cement :2 coarse sand :4 graded stone aggregate 20 mm nominal size) neatly finished complete as per standard design :Inside size 60 x 60cm and 60cm deep including C.I. cover with frame (light duty) 455x610mm internal diameter total weight of cover and frame to be not less than 38 kg. (weight of cover 23 kg).

4

-

-

... More
Providing M.S. footrests including fixing in manholes with 20 x 20 x 10 cm cement concrete block 1:3:6 (1 cement :3 coarse sand :6 graded stone aggregate 20 mm nominal size) as per standard design :

42

-

-

... More
Providing, fixing and jointing UPVC (SWR) pipe in vertical and horizontal position Type-B for soil waste, rain water and vent or anti syphon age pipe of approved make including all fittings (plain or door) e.g. bends, junctions, cowls, offsets, access pieces jointing including fixing the pipe on the wall/ceiling with suitable clamps ,holder bat clamps and anchor fastener of approved design to Upvc (spun) pipe embedded, cement concrete block 10x10x 10 cm of 1:2:4 ( 1 cement: 4 coarse sand: 4 graded stone aggregate 20 mm nominal size), cutting holes in wall and floors, excavation, refilling and disposal of surplus earth where required and marked good complete etc. and as per direction of Engineer in Charge. Make - (Jain Plumbing or its equivelent price in prince/finolex): 160 mm diameter.

100

-

-

... More
Supplying, installation, testing and commissioning of main fire pump (MFP / EP) suitable for water discharge of 1600 to 1800 LPM at 70 to 55 m head driven by electric motor 415 volts, 3 phase 50 Hz, AC supply of 30kW or of suitable kW capacity for manual/automatic operation and consisting of following :Horizontal type, single stage, centrifugal/split casing pump of cast iron body & bronze impeller with stainless steel shaft (SS410 grade), mechanical seal conforming to IS 1520. Squirrel cage induction motor, TEFC, synchronous speed 3000 RPM, suitable for operation with IP 55 protection for enclosure, horizontal foot mounted type with Class-'F' insulation, conforming to IS-325 M.S. fabricated common base plate, coupling, coupling guard, foundation bolts etc. as required. Erected on provided suitable size cement concrete foundation duly plastered with anti vibration pads with perfect aligning, proper levelling complete pump set with accessories duly painted with two coats of synthetic enamel paint of fire red colour over a coat of primer (ISC code 536 as per IS 2932 of 2003) complete, as per specification no. FF-MFP/SSC/EP

1

-

-

... More
Supplying, installation, testing and commissioning of main fire pump (MFP/DP) suitable for water discharge of 1600 to 1800 LPM at 70 to 50 m head driven by 45 HP or suitable HP capacity diesel engine at required working speed suitable for manual/automatic operation and consisting of following : Horizontal type, single stage, centrifugal casing pump of cast iron body & bronze impeller with stainless steel shaft (SS410 grade), mechanical seal conforming to IS 1520. Water cooled with radiator, diesel engine conforming to relevant IS standard complete with auto starting mechanism, 12/24 volts DC electric starting equipment with battery of required AH capacity with necessary charger suitable to work on 230v, 50Hz AC supply, diesel tank of minimum 150ltr capacity with first filling of diesel up to 100% level with necessary piping with valves up to engine, exhaust pipe extended up to 10 m outside pump house duly insulated with 50 mm thick glass wool with 1.0 mm thick aluminium sheet cladding, residential silencer, instruments and protection as per standard specification, stop solenoid for auto stop in the event of fault with audio indications etc. as required. M.S. fabricated common base plate, coupling, coupling guard, foundation bolts etc. as required. Erected on provided suitable size cement concrete foundation duly plastered with anti vibration pads with perfect aligning, proper levelling complete pump set with engine assembly and accessories duly painted with two coats of synthetic enamel paint of fire red colour over a coat of primer (ISC code 536 as per IS 2932 of 2003) complete, as per specification no. FF-MFP/SSC/DP

1

-

-

... More
Supplying, installation, testing and commissioning of jockey fire pump (JP) suitable for water discharge of 180 to 240 LPM at 70 to 50 m head driven by electric motor 415 volts, 3 phase 50 Hz, AC supply of 5.5 kW or of suitable kW capacity for manual/automatic operation and consisting of following :Horizontal/vertical type, multi stage, centrifugal casing pump of cast iron body & bronze impeller with stainless steel shaft (SS410 grade), mechanical seal conforming to IS 1520. Squirrel cage induction motor, TEFC, synchronous speed 3000 RPM, suitable for operation with IP 55 protection for enclosure, horizontal foot mounted type with Class-'F' insulation, conforming to IS-325. M.S. fabricated common base plate, coupling, coupling guard, foundation bolts etc. as required. Erected on provided suitable size cement concrete foundation duly plastered with anti vibration pads with perfect aligning, proper levelling complete pump set with accessories duly painted with two coats of synthetic enamel paint of fire red colour over a coat of primer (ISC code 536 as per IS 2932 of 2003)complete, as per specification no. FF-MFP/JP

2

-

-

... More
Supplying, installation, testing and commissioning of booster fire pump [BP] suitable for water discharge of 450 LPM at 35 m head driven by electric motor 415 volts, 3 phase 50 Hz, AC supply of 5.5 kW or of suitable kW capacity for manual/automatic operation and consisting of following : Horizontal/vertical type, single/multi stage, centrifugal casing pump of cast iron body & bronze/CI impeller with stainless steel shaft (SS410 grade), mechanical seal conforming to IS 1520. Squirrel cage induction motor, TEFC, synchronous speed 3000 RPM, suitable for operation with IP 55 protection for enclosure, horizontal foot mounted type with Class-'F' insulation, conforming to IS-325. M.S. fabricated common base plate, coupling, coupling guard, foundation bolts etc. as required. Erected on provided suitable size cement concrete foundation duly plastered with anti vibration pads with perfect aligning, proper levelling complete pump set with accessories duly painted with two coats of synthetic enamel paint of fire red colour over a coat of primer (ISC code 536 as per IS 2932 of 2003) complete, as per specification no. FF-MFP/BP

1

-

-

... More
Supplying and erecting G.I. pipe ‘C’ class ERW 150 mm dia with necessary fittings complete as per specification no. FF-PP

52.63

-

-

... More
Providing coating of bitumen paint & 4mm thick wrapping for underground 150 mm ring main of fire fighting system.

52.63

-

-

... More
Supplying and erecting G.I. pipe ‘C’ class ERW 25 mm dia with necessary fittings complete as per specification no. FF-PP

56

-

-

... More
Supplying and erecting G.I. pipe ‘C’ class ERW 50 mm dia with necessary fittings complete as per specification no. FF-PP

31

-

-

... More
Supplying and erecting G.I. pipe ‘C’ class ERW 65 mm dia with necessary fittings complete as per specification no. FF-PP

9.8

-

-

... More
Supplying and erecting G.I. pipe ‘C’ class ERW 75/80 mm dia with necessary fittings complete as per specification no. FF-PP

4.69

-

-

... More
Supplying and erecting G.I. pipe ‘C’ class ERW 150 mm dia with necessary fittings complete as per specification no. FF-PP

18.05

-

-

... More
Supplying and erecting gun metal single outlet hydrant valve fitted with necessary accessories complete as per specification no. FF-VL/HV

10

-

-

... More
Supplying and erecting 75/80 mm dia. cast iron double flange butterfly valve of size complete with PN16 pressure rating, as per specification no. FF-VL/BFV

1

-

-

... More
Supplying and erecting 50 mm dia. cast iron double flange butterfly valve of size complete with PN16 pressure rating, as per specification no. FF-VL/BFV

2

-

-

... More
Supplying and erecting 150 mm dia. cast iron double flange butterfly valve of size complete with PN16 pressure rating, as per specification no. FF-VL/BFV

2

-

-

... More
Supplying and erecting 150 mm dia. cast iron double flange sluice valve complete with PN16 pressure rating, as per specification no. FF-VL/SV

3

-

-

... More
Supplying and erecting 150 mm dia cast iron double flange NRV complete with PN16 pressure rating, as per specification no. FF-VL/NRV

2

-

-

... More
Supplying and erecting 150 mm dia Cast Iron end line strainer of Y-type flanged end pattern, PN16 pressure rating, SS screen, end connection with Flanged / Screwed / Socket Weld / Butt Weld End etc with standard OAR (open area Ratio) for positive suction complete as per specification no. FF-VL/ELS

7

-

-

... More
Supplying and erecting 63mm dia, reinforced rubber lined (R.R.L.) hose pipe, 15m in length, fitted with necessary accessories complete as per specification no. FF-FFA/RRL

7

-

-

... More
Supplying and installing wall mounting swinging hose reel drum fitted with 19 mm dia. 30m long high pressure polypropylene (Polyhose) along with necessary accessories complete as per specification no. FF-FFA/HV

7

-

-

... More
Supplying and erecting stainless steel branch pipe 63 mm dia fitted with 20 mm dia detachable hexagonal nozzle complete as per specifications no. FFFFA/NZ

7

-

-

... More
Supplying and erecting 150 mm dia fire brigade header suitable for supplying water in fire tank complete as per specification no. FF-FA/FBC

1

-

-

... More
Supplying and erecting 300 mm dia 1.5m in height air vessel / tank fabricated from min 5mm thick M.S. sheet complete as per specification no. FF-FFA/ACT

2

-

-

... More
Supplying, erecting, testing and commissioning of quartzoid bulb sprinkler, 15 mm (½") dia. NBCM Body chrome finished, 68º C fixed temperature rating with deflector disc of conventional construction complete as per specification no. FFSPR.

24

-

-

... More
Supplying and erecting 12/15 mm dia pressure switch with provided isolation valve, G.I. nipple, elbow, etc complete as per specification no. FF-FFA/PS

1

-

-

... More
Supplying, erecting, testing & commissioning of fire pump control panel (FCP) of cubical construction, floor mounted type, fabricated from minimum 2 mm thick CRCA sheet, compartmentalised with hinged lockable doors, with enclosure protection class IP54, duly powder coated or painted with accessories duly painted with two coats of synthetic enamel paint of fire red colour over a coat of primer (ISC code 536 as per IS 2932 of 2003), cable alley, interconnection with suitable size solid copper busbar strip of adequate size for all power connections having switchgears and accessories, mountings and internal wiring with adequate size copper conductor cable, earth terminals, numbering etc. complete in all respect, suitable for satisfactory operation of main fire pump and jockey (pressurisation) pumps (1working+1standby) with necessary accessories, wiring cabling along with allied accessories with following incoming and outgoings, suitable for automatic & manual operation on 415V, 3 phase, 50Hz ac supply as per specifications the capacity of electric motor driven pump are as follows a. Main fire pump(MFP) having capacity of 22kW 1no (1 working) b. Jockey pump(JP) capacity of suitable capacity 2 nos(1 working +1 standby, alternate run per start in auto mode) comprises of the following features & switchgears: 1. Main incomer FP SFU having rotary handle with HRC fuses of suitable rating. 2. Electrolytic grade copper strips for busbar of suitable sizes for main incomer and branches to motor SFU's, starters & outgoing terminals with necessary accessories like stainless steel nut bolts with spring washers for connections, mounted on required no of epoxy or porcelain support insulators of suitable ratings etc. 3. Individual pump TPN SFU having rotary handle with HRC fuses of suitable rating 4. Digital voltmeter & ammeter & RYB indicating lamps & push buttons & SPP, O/L & phase reversal protection with emergency stop switch. 5. TPN SPD 100kA Type 1 +2 tested. 6. Required pressure transducer with pressure indication on panel with cabling required for monitoring & automatic operation of fire pumps. 7. System controller to control operation of main electric fire pump, jockey (pressurization) pumps in sequence with interlocking for operation of pumps as per specification with automatic/manual operation with selector switch & alternate run of standby Pumps consisting of relays, timers. sensors, annunciation window for fault indication, complete as per specification. 8.Suitable capacity electric motor starters for all individual pumps with necessary push buttons & indications. 9. Siren of required capacity to be activated when main pump starts & allied accessories as per requirements of local CFO or as directed by engineer in charge. 10. Danger board as per IS. 11. Spare HRC fuses minimum 2nos of each individual rating with required bakelite fuse holder for main & jockey fire pumps MFP=(1working), JP = (1working+1standby, alternate run per start in auto mode) complete panel, as per specification no. FF-MFP/ECP

1

-

-

... More
For addition of fire sprinkler system to basic fire hydrant system control panel(FCP) which includes one main electric motor driven fire pump MFP (1working) having __kW capacity & relevant capacity jockey pumps, add as follows in the basic cost of Item no 13-5-1 towards increased capacity switchgears busbar and additional motor starters for main & jockey pumps along with necessary accessories with software & hardware for main & jockey fire pumps additional Sprinkler system MFP=(1working)@22kW, JP = (1working+1standby, alternate run per start in auto mode) @relevant capacity. For main electric motor driven fire sprinkler system pump of 30kW capacity (1Working) & relevant capacity jockey pumps (1working+1standby, alternate run per start in auto mode, add Rs….

1

-

-

... More
For addition of standby main diesel engine driven fire pump (1 standby), add as follows in the basic cost of Item no 13-5-1 towards required 12/24 v battery charger and diesel engine starter along with necessary accessories, indicators etc. with necessary interlocking and updation of control logic with interlocking for operation of pumps MFP for main (1working+1standby mode) & jockey fire pumps (1working+1standby, alternate run per start in auto mode) , add Rs....... The control for diesel engine comprises of automatic/manual selector switch & 3 attempts starting device, timers and relays as required, push buttons, start/stop in manual mode indicating lamp for high/ low Lub. oil pressure, high water temp and engine on indication battery charger suitable for 12V/24 V DC with boost and trickle selector switch, 0-30 V DC voltmeter, and 0-20 A DC ammeter with all standard relays and accessories required for automatic operation of diesel engine with interlocking for operation of main fire pumps.

1

-

-

... More
For addition of booster pump for fire hydrant/sprinkler, add as follows in the basic cost of item no 13-5-1 towards necessary accessories, indicators etc. with necessary interlocking and updation of control logic, add Rs.......for 5.5/ 7.5 kW centrifugal type booster pump 1no(1working) , add Rs…....

1

-

-

... More
Supplying and Installing following size perforated type 16 SWG, M.S.cable tray of GI pregalvanised/hot dip galvanised/ powder coated finish, in convenient sections, joined with connectors, suspended from the ceiling with suitable MS suspenders including bolts and nuts, painting suspenders etc, complete as required.150 mm width X 50 mm depth X 1.6 mm thickness

22

-

-

... More
Supplying and Installing following size perforated type 16 SWG, M.S.cable tray of GI pregalvanised/hot dip galvanised/ powder coated finish, in convenient sections, joined with connectors, suspended from the ceiling with suitable MS suspenders including bolts and nuts, painting suspenders etc, complete as required.300 mm width X 50 mm depth X 1.6 mm thickness

20

-

-

... More
Supplying and laying 25 mm x 5 mm GI strip at 0.5 m below ground as strip earth electrode including soldering etc. as required

23

-

-

... More
Supply of 3 1/2 core armoured PVC/XLPE insulated, PVC sheathed aluminium conductor cable of 1.1 KV grade with ISI mark conforming to IS:1554(Part I) ,IS:7098(Part I) with latest amendments of following size.31/2x 240 sq.mm.(aluminium conductor)

23

-

-

... More
Supply of 3 core armoured PVC/XLPE insulated, PVC sheathed aluminium conductor cable of 1.1 KV grade with ISI mark conforming to IS:1554(Part I) ,IS:7098(Part I) with latest amendments of following size.3 x 70 Sqmm(aluminium conductor)

19

-

-

... More
Supply of 3 core armoured PVC/XLPE insulated, PVC sheathed copper conductor cable of 1.1 KV grade with ISI mark conforming to IS:1554(Part I) ,IS:7098(Part I) with latest amendments of following size.3 x 10 Sq mm (Copper conductor)

19

-

-

... More
Supply of 2 core armoured PVC/XLPE insulated, PVC sheathed copper conductor cable of 1.1 KV grade with ISI mark conforming to IS:1554(Part I) ,IS:7098(Part I) with latest amendments of following size.2 x 2.5 Sq mm (Copper conductor)

14

-

-

... More
Laying of one number PVC insulated and PVC sheathed/XLPE power cable of 1.1 KV grade of size not exceeding 25 sq.mm on surface, etc. complete as required

33

-

-

... More
Laying of one number PVC insulated and PVC sheathed/XLPE power cable of 1.1 KV grade of size exceeding 120 sq.mm but not exceeding 400 sq.mm on surface, etc. complete as required

23

-

-

... More
Supplying and making cable end terminations with brass compression gland and aluminium lugs for folowing sizes of 3 1/2 Core PVC insulated PVC sheathed/XLPE aluminium conductor cable of 1.1 KV grade, complete as required.'(10) 3 1/2 x 240 Sq. mm.

2

-

-

... More
Supplying and making end termination with brass compression gland and aluminum lugs for following size of PVC insulated and PVC sheathed / XLPE aluminum conductor cable of 1.1 KV grade as required.3 x 70 Sqmm

4

-

-

... More
Supplying and making end termination with brass compression gland and aluminum lugs for following size of PVC insulated and PVC sheathed / XLPE aluminum conductor cable of 1.1 KV grade as required.3 x 10 Sq mm (For Copper conductor)

4

-

-

... More
Supplying and erecting M.S./CRCA cabinet for housing Floor Hydrant valve, hose pipe, hose reel and branch pipe (size 1000 x 736 x 736 mm.) made from 16 SWG sheet and angle iron 25 x 25 x 4 mm. having front doors with viewing glass (8"x6") and locking arrangement with necessary fixing material such as rubber bidding etc. duly painted in post box red colour( Code 538 of IS 5)

7

-

-

... More
Supplying & erecting Carbon Dioxide (CO2) fire extinguisher of 4.5 kg. capacity cartridge type conform to IS 2878 /15683 complete erected with necessary clamp made from 50 x 6 mm. M. S. flat with nut & bolts routed in wall complete.

7

-

-

... More
Supplying, Installation, Testing and Commissioning of standard Fire Man's axe with heavy insulated rubber conforming to IS : 926

7

-

-

... More
Providing and fixing water based CO2 type extinguishers consisting of welded M.S. cylindrical body, squeeze lever discharge valve 30 cms long high pressure discharge hose, discharge nozzle, suspension bracket, ISI marked as per IS:15683 finished externally with red enamel paint and fixed to wall with brackets complete with internal charges. Capacity 9 lit.

7

-

-

... More
Providing and fixing mechanical foam type (ISI marked) fire extinguishers consisting of welded M.S. cylindrical body squeeze lever discharge valve 30 cm long high pressure discharge hose, discharge nozzle suspension bracket as per IS:15683 marked finished externally with red enamel paint and fixed to wall with brackets complete with internal charger. Capacity 9 lit.

7

-

-

... More
Providing & fixing flow switch in following sizes M.S. pipe including connection etc as required.150mm dia

6

-

-

... More
Providing, fixing, testing & commissioning of installation control valve of cast iron body, brass/bronze working parts comprising of water motor alarm, bronze seat clapper, clapper arm and hydraulically driven mechanical gong bell to sound continuous alarm when the wet riser/sprinkler system activates, pressure gauges, emergency releases, strainer, pressure switch, cock valve complete with drain valve and bypass, test control box, ball valves, MS pipe of required size, flanges, orifice plate, gasket etc of follwing sizes as required :80mm dia

1

-

-

... More
Providing, fixing, testing & commissioning of installation control valve of cast iron body, brass/bronze working parts comprising of water motor alarm, bronze seat clapper, clapper arm and hydraulically driven mechanical gong bell to sound continuous alarm when the wet riser/sprinkler system activates, pressure gauges, emergency releases, strainer, pressure switch, cock valve complete with drain valve and bypass, test control box, ball valves, MS pipe of required size, flanges, orifice plate, gasket etc of follwing sizes as required :150mm dia

1

-

-

... More
Supplying and drawing of Cat - 6 UTP, 4 pair annealed tinned copper conductor PVC insulated, PVC sheathed, unarmoured data cable in existing surface/recessed steel/PVC conduit of appropriate size including connection, etc. complete as required.

1300

-

-

... More
Supplying and fixing of following sizes of rigid PVC conduit alongwith accessories in surface(medium)/recess(heavy) including cutting the wall and making good the same in case of recessed conduit as required.

1300

-

-

... More
Supplying, installation and testing of suitable size modular GI box , modular plate and cover complete with RJ-45 connector(modular LAN socket TX1000/ CAT6) including concealed metal box/surface GI/PVC Box, modular plate, punching, identifying, complete as required.

13

-

-

... More
Supplying and fixing 9U wall mount rack (Dimension-DxWxH – 500x600x500 mm) as per specification No. WG-NAS/RAK

1

-

-

... More
Supplying and fixing 24 port patch panel with tool-less keystone jacks in provided U Rack complete as per specification no. WG-NAS/PP

1

-

-

... More
Supplying, fixing, and configuring 8-ports 1 G unmanaged gigabit POE switch erected in provided rack complete.

4

-

-

... More
Supplying, fixing, and configuring 24 ports, POE switch in provided rack as per specification No. WG-NWC/ENS

1

-

-

... More
Supplying and installing armoured single mode optical fibre cable with 6 fiber, core dia 50/125μm (OS1/OS2) 10/40 GBPS speed in provided underground HDPE pipe complete.

50

-

-

... More
Supplying, erecting, testing and commissioning of 3kVA capacity online pure sine wave with backup time of 30 minutes. PWM & IGBT based UPS with 0.8 to unity output pf, single phase input & 1 phase output complete with all protections as per specification no. AP-UPS

1

-

-

... More
Supplying and erecting 12V/150Ah tubular battery with battery terminal wire, duly charged with 36 months warranty complete.

1

-

-

... More
Supply, of 4MP IP Dome Camera 1/3" 4 MP progressive scan imager 2688 x 1520 resolution, 3.6 mm Fixed lens, True day/night (IR-cut filter) Wide Dynamic Range up to 120 dB, Low-light performance down to 0.08 lux (color) or 0 lux with IR LEDs on, Up to 98 ft (30 m) IR illumination, depending on scene reflectance, H.265 Smart Codec, Dual stream support PoE (802.3af) or 12 VDC support, Plug-and-play compatible with Honeywell Performance Series Embedded NVRs, IP66 and IK10-rated rugged housing.

5

-

-

... More
SITC of 4MP IP Bullet Camera 1/3" 4 MP progressive scan imager 2688 x 1520 resolution, 3.6 mm Fixed lens, True day/night (IR-cut filter) Wide Dynamic Range up to 120 dB, Low-light performance down to 0.08 lux (color) or 0 lux with IR LEDs on, Up to 98 ft (30 m) IR illumination, depending on scene reflectance, H.265 Smart Codec, Dual stream support PoE (802.3af) or 12 VDC support, Plug-and-play compatible with Honeywell Performance Series Embedded NVRs, IP66 and IK10-rated rugged housing

20

-

-

... More
SITC of Network Video Rrecorder 40 Channel IH+265/H.265/H.264 video formats Up to 40 channel inputSupports live view, storage, and playback of the connected camera at up to 8MP resolution1×RJ45 self-adaptive 10/100 Mbps network interface, HDMI and VGA simultaneous output, HDMI Video output at up to 4K (3840 × 2160) resolution IH+265, compression effectively reduces the storage space and costs by up to 75 Motion Detection, Video Loss, Alarm recording, Buzzer, Each Channel Backup, Password Control, Firmware Update and Mobile applications all complete etc all complete

1

-

-

... More
Supply, installation, testing & commissioning of 6TB Surveillance Hard Disk

1

-

-

... More
Supply, of 43" HD LED TV including decodes and all accessories complete as required in accordance with laid specification or upto the satisfaction of engineer in charge.

1

-

-

... More
Supplying and erecting LED square / circular Max. 14 W down lighter/Panel Light having pressure die-cast aluminium housing, polystyrene diffuser having system lumens output of Min. 1500 Lumens, min. efficacy of 110 lumen/W, CRI80, CCT upto 6500K, Beam Angle of 120 deg., max. ripple of 5%, THD10%, p.f. 0.95, operating range of 120-270V, surge protection of 2.5 kV, Life class of 50,000 Hrs. at L70B50, including driver, having mounting arrangement with board for surface type or spring loaded mounting clips

16

-

-

... More
Supply and erecting of 9 inch (225 mm sweep) exhaust fan with double ball bearings, 1400 rpm, complete with all accessories.

8

-

-

... More
Supplying and erecting anodized aluminium corridor / passage light LED fitting (4 feet) Max. 22W with high transitivity diffuser with system lumens output of Min.2200 lumens , min. efficacy of 100 lumen/W, CRI80, CCT upto 6000K, Beam Angle of 110 deg., Ripple5%, THD10%, p.f. 0.95, operating range of 200-270V, surge protection of 2 kV, Life class of 50,000 Hrs. at L70B50, including driver, with end caps on provided PVC Block / wooden board with 3 years warranty

49

-

-

... More
Supply and erecting of 48 inch ( 1200mm sweep) ceiling fan, double ball bearing type, , complete with all accessories. CAT A

45

-

-

... More
Supplying and erecting LED square / circular Max. 11 W down lighter/Panel Light having pressure die-cast aluminium housing, polystyrene diffuser having system lumens output of Min. 1200 Lumens, min. efficacy of 110 lumen/W, CRI80, CCT upto 6500K, Beam Angle of 120 deg., max. ripple of 5%, THD10%, p.f. 0.95, operating range of 120-270V, surge protection of 2.5 kV, Life class of 50,000 Hrs. at L70B50, including driver, having mounting arrangement with board for surface type or spring loaded mounting clips complete with 3 years warranty.

12

-

-

... More
Supplying and erecting LED Panel Light(600mm X 600mm) Max. 35 W having CRCA powder coated housing, polystyrene diffuser having system lumens output of Min 4200 Lumens, min. efficacy of 120 lumen/W, CRI80, CCT upto 6500K, Beam Angle of 120 deg., max. ripple of 5%, THD10%, p.f. 0.95, operating range of 120-270V, surge protection of 2.5 kV, Life class of 50,000 Hrs. at L70B50 including driver, having mounting arrangement with board for surface type or spring loaded mounting clips complete with 3 years warranty.

112

-

-

... More
Supply of 3 1/2 core armoured PVC/XLPE insulated, PVC sheathed aluminium conductor cable of 1.1 KV grade with ISI mark conforming to IS:1554(Part I) ,IS:7098(Part I) with latest amendments of following size.' 3 1/2 Core 70 sq.mm

280

-

-

... More
'Supply of 3 1/2 core armoured PVC/XLPE insulated, PVC sheathed aluminium conductor cable of 1.1 KV grade with ISI mark conforming to IS:1554(Part I) ,IS:7098(Part I) with latest amendments of following size.31/2 Core 95sq.mm

100

-

-

... More
'Supply of 3 1/2 core armoured PVC/XLPE insulated, PVC sheathed aluminium conductor cable of 1.1 KV grade with ISI mark conforming to IS:1554(Part I) ,IS:7098(Part I) with latest amendments of following size. 3 1/2 Core 300 sq.mm

40

-

-

... More
'Supply of following size of 3 core, HV, 11 KV grade, ISI mark, XLPE cable with stranded compact circular aluminium conductor, conductor screened with extruded semiconducting compound, XLPE insulated, insulation screned with extruded semiconducting compound in combination with copper tape(0.3 KA for 1Sec.) cores laid off,inner sheath of PVC tape,galvanised steel flat strip armoured and overall PVC sheathed cable conforming to IS:7098(Part II) with latest amendments. 3 Core 300sq.mm

200

-

-

... More
Laying of one number PVC insulated and PVC sheathed/XLPE power cable of grade exceeding 11 KV but not exceeding 33 KV grade of size exceeding 120 sq.mm but not exceeding 400 sq.mm direct in ground including excavation in the form of a trench as per Cable Trench Drawing provided by the Engineer-Incharge,sand cushioning with screened sand bed of 20mm thick , protective covering with bricks placed lenghtwise on top of cable all over the run and backfilling the excavated earth without stones or hard material and making the surface proper with 15 cm crown on the top complete as required.Rocky strata

200

-

-

... More
Laying of one number PVC insulated and PVC sheathed/XLPE power cable of 1.1 KV grade of size exceeding 120 sq.mm but not exceeding 400 sq.mm direct in ground including excavation in the form of a trench as per Cable Trench Drawing provided by the Engineer-Incharge,sand cushioning with screened sand bed of 20mm thick , protective covering with bricks placed breadth-wise on top of cable all over the run( the brick protection shall cover the cable and project atleast 5 cms over the sides of the cable)and backfilling the excavated earth without stones or hard material and making the surface proper with 15 cm crown on the top complete as required.'(a) In soily strata

40

-

-

... More
Laying of one number PVC insulated and PVC sheathed/XLPE power cable 1.1 KV grade of size exceeding 120 sq. mm but not exceeding 400 sq. mm on surface, etc complete as rewquired

105

-

-

... More
Laying of one number PVC insulated and PVC sheathed/XLPE power cable of 1.1 KV grade of size exceeding 25 sq.mm but not exceeding 400 sq.mm in the existing masonry open duct, etc. complete as required.

275

-

-

... More
Supplying and making cable end terminations with brass compression gland and copper lugs for folowing sizes of 3 1/2 Core PVC insulated PVC sheathed/XLPE aluminium conductor cable of 1.1 KV grade, complete as required.'(4) 3 1/2 x 70 Sq. mm.

10

-

-

... More
Supplying and making cable end terminations with brass compression gland and copper lugs for folowing sizes of 3 1/2 Core PVC insulated PVC sheathed/XLPE aluminium conductor cable of 1.1 KV grade, complete as required.'(6) 3 1/2 x95 Sq. mm.

4

-

-

... More
Supplying and making cable end terminations with brass compression gland and copper lugs for folowing sizes of 3 1/2 Core PVC insulated PVC sheathed/XLPE aluminium conductor cable of 1.1 KV grade, complete as required(10) 3 1/2 x 300 Sq. mm.

4

-

-

... More
Supplying and Installing following size perforated type 16 SWG, M.S.cable tray of GI pregalvanised/hot dip galvanised/ powder coated finish, in convenient sections, joined with connectors, suspended from the ceiling with suitable MS suspenders including bolts and nuts, painting suspenders etc, complete as required.300mm width x 50mm depth

155

-

-

... More
Supply of 3 core armoured PVC/XLPE insulated, PVC sheathed copper conductor cable of 1.1 KV grade with ISI mark conforming to IS:1554(Part I) ,IS:7098(Part I) with latest amendments of following size.3 Core 4 sq.mm

90

-

-

... More
Supply of 4 core armoured PVC/XLPE insulated, PVC sheathed copper conductor cable of 1.1 KV grade with ISI mark conforming to IS:1554(Part I) ,IS:7098(Part I) with latest amendments of following size. 4 Core 4 sq.mm

50

-

-

... More
Laying of one number PVC insulated and PVC sheathed/XLPE power cable of 1.1 KV grade of size not exceeding 25 sq.mm on surface, etc. complete as required

90

-

-

... More
Earthing with copper earth plate 600 mm x 600 mm x 3 mm thick including accessories and providing masonry enclosure with CI/RCC cover having locking/lifting arrangement and watering pipe etc. (but without charcoal or coke and salt) as required as per the Earthing Drawing provided by the Engineer-Incharge.The scope of work includes the following: a) Excavation of pit of size 1.0x1.0x 3.0 mtrs(min) and disposal of excavated soil. c)Watering GI pipe, 20 mm Class B, with funnel as per specs. d) Charcoal/salt as per specs ( paid seperately). e) Refilling the pit of size 1.0x1.0x 3.0 mtrs(min) with soft black agriculture soil of minimum resistivity i/c transportation. e)Masonary chamber with proper foundation, cover plate and locking arrangement. f) Testing of earth value with earth megger and certifications of its value. g)watering arrangement(plumbing will be paid seperately).

6

-

-

... More
Earthing with GI earth plate 600 mm x 600 mm x 6 mm thick including accessories and providing masonry enclosure with CI/RCC cover having locking/Lifting arrangement and watering pipe etc. (but without charcoal or coke and salt) as required as per the Earthing Drawing provided by the Engineer-Incharge.The scope of work includes the following: a) Excavation of pit of size 1.0x1.0x 3.0 mtrs(min) and disposal of excavated soil. c)Watering GI pipe, 20mm, Class B, with funnel as per specs. d) Charcoal/salt as per specs ( paid seperately). e) Refilling the pit of size 1.0x1.0x 3.0 mtrs(min) with soft black agriculture soil of minimum resistivity i/c transportation. e)Masonary chamber with proper foundation, cover plate and locking arrangement. f) Testing of earth value with earth megger and certifications of its value. Aluminium tag with embossed earthing value to be attached to the pipe.g)watering arrangement(plumbing will be paid seperately).

14

-

-

... More
Providing and fixing 25 mm x 5 mm copper strip on surface r in recess for coneections etc. as required

100

-

-

... More
Providing and fixing 25 mm x 5 mm GI strip on surface or in recess for coneections etc. as required

250

-

-

... More
Providing and fixing 4 mm dia copper wire on surface or in recess for loop Earthing . as required

50

-

-

... More
Extra for using salt and charcoal for GI or copper plate earth electrode as required( 96 Kgs of Charcoal and 5 Kgs of Salt)

20

-

-

... More
Supplying, erecting, testing & commissioning 11 kV, 630A, 21kA/3sec, 3 way outdoor, extensible motorised SCADA compatible RMU, internal arc tested consisting of 2 nos. feeder with 2 LBS and 1 no. feeder with 1 VCB. compliant to IEC 62271 -100, 200 and 102, as per specification no. SW-HTS/RMU SCADA

1

-

-

... More
Supplying and making Indoor cable end termination with heat shrinkable kit for following sizes of PVC insulated PVC sheathed/XLPE aluminium conductor cable upto 11 KV grade, complete as required.'(d) 11 KV, 3 Core x 240 - 300sq.mm

4

-

-

... More
Supplying and making Outdoor cable end termination with heat shrinkable kit for following sizes of PVC insulated PVC sheathed/XLPE aluminium conductor cable upto 11 KV grade, complete as required.(d) 11 KV, 3 Core x 240 - 300sq.mm

1

-

-

... More
Supplying, installing, testing & commissioning 3 phase, 11/0.433 kV, 50 Hz., 200 kVA, Mineral oil immersed and naturally cooled outdoor type, copper wound Non-sealed transformer delta/star connected with additional neutral brought out on load side, temperature rise should not exceed 45℃ by thermometer in oil and 50 ℃ by the resistance method in winding at full load rating, using type A winding insulation (kraft paper) with HV tapping (with off load tap changer)off load +2.5 to -5 in steps of 2.5%, having 4 number of tap positions, with standard accessories complete with test certificate with losses below 780 Watts at 50% load, 2300 Watts at 100% load as per IS:1180 (part 1) : 2014 , with necessary p

1

-

-

... More
Supplying and erecting fencing of section having size 2450 mm in height from ground level and 1200 mm width with angle iron frame work erected in C C foundationand painted as per specification No SS-AS/FSG

12

-

-

... More
Supplying and erecting double leaf hinged dooreach1500mm in width x 1850 mm in height using B class ,GI pipe with angle iron supports, chain link wiremesh (jali) complete supported on channel iron, erected in foundation, and painted as per specification no SS-AS/DLD

1

-

-

... More
Supplying & erecting Carbon Dioxide (CO2) fire extinguisher of 4.5 kg. capacity cartridge type conform to IS 2878 /15683 complete erected with necessary clamp made from 50 x 6 mm. M. S. flat with nut & bolts routed in wall complete.

6

-

-

... More
Supplying and fixing following way SPN sheet steel MCB distribution board 240 V on surface/ recess complete with tinned copper busbar neutral busbar earth bar dinnbar detachable gland plate interconnections phosphotized and powder painted including earthing etc. as required ( but without MCB/RCCB/Isolator)'(o) 12way double door Cat B

4

-

-

... More
Supplying and fixing following way TPN sheet steel, single door, Horizontal type MCB distribution board 415 V on surface/ recess complete with tinned copper busbar neutral busbar earth bar dinnbar detachable gland plate interconnections phosphotized and powder painted including earthing etc. as required ( but without MCB/RCCB/Isolator) 6way (8+18), double door, Horizontal type Cat B

14

-

-

... More
Supplying and fixing 6 A to 32 A, C series MCB suitable for lighting and other loads of following poles in the existing MCB DB complete with connections testing and commissioning etc as required.(a) SP, Cat A

107

-

-

... More
Supplying and fixing 6 A to 32 A, C series MCB suitable for lighting and other loads of following poles in the existing MCB DB complete with connections testing and commissioning etc as required. DP, Cat A

5

-

-

... More
Supplying and fixing 32 A, C series MCB suitable for lighting and other loads of following poles in the existing MCB DB complete with connections testing and commissioning etc as required. (e) TPN, Cat B

14

-

-

... More
'Supplying and fixing following rating double pole (single pole and neutral) 240 V RCCB having a sensitivity current upto 300mA in the existing MCB DB complete with connections testing and commissioning etc as required(b) 40 A, Cat A

5

-

-

... More
Supplying and fixing following rating four pole (triple pole and neutral) 415 V RCCB having a sensitivity current upto 300mA in the existing MCB DB complete with connections testing and commissioning etc as required'(b) 40 A, Cat A

14

-

-

... More
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor single core cable in the independent surface / recess PVC conduit ( medium)of appropriate size as required.'(b) 2 x 2.5 sq.mm + 1 x 2.5 sq.mm earthwire (20mm Conduit)

1435

-

-

... More
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor single core cable in the independent surface / recess PVC conduit ( medium)of appropriate size as required.2 x 4 sq.mm + 1 x 4 sq.mm earthwire (20mm Conduit)

1150

-

-

... More
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor single core cable in the independent surface / recess PVC conduit ( medium)of appropriate size as required.'4 x 4 sq.mm + 2 x 4 sq.mm earthwire (25mm Conduit)

1400

-

-

... More
Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in recessed PVC conduit(heavy) with modular switch, modular plates, suitable size modular GI box of specified Category and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required. Group B -- with Cat A Modular Accessories

143

-

-

... More
Supplying and fixing 3 pin 5/6 A modular socket outlet and 5/ 6 A modular switch on board the modular surface/recessed PVC/GI modular box by suitably increasing its modular capacity, modular plate and cover including connection painting etc. as required.

26

-

-

... More
Wiring for twin control light point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in recessed PVC conduit(heavy) with 2 way modular switch, modular plates, suitable size modular GI box of specified Category and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required.

1

-

-

... More
Wiring for group controlled light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in recessed PVC conduit(heavy) and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required.

104

-

-

... More
Supplying and fixing suitable size modular PVC box with modular plate and cover in front on surface or in recess including providing and fixing 1 no 6 pin 15/16 A modular socket outlet and 1 nos 15/ 16 A modular switch connection painting etc. as required. ( For workstations)(a) Cat A

23

-

-

... More
Supplying and fixing 3 pin 5/6 A modular socket outlet and 5/ 6 A modular switch on board the modular surface/recessed PVC/GI modular box by suitably increasing its modular capacity, modular plate and cover including connection painting etc. as required.

27

-

-

... More
Supplying and fixing PVC synthetic elastomer electrically insulating mat with class B insulation conforming to IS: 15652 – 2006 & CPRI tested having 2.5 mm thickness upto 11 Kv

10

-

-

... More
Supplying and fixing 10 A 240 V SPN industrial type socket outlet with 2 pole and earth metal enclosed plug top alon with 20 A, C series SP MCB in sheet steel enclosure in surface or in recess with chained metal cover for the socket outlet and complete with connections testing and commissioning etc. as required.

34

-

-

... More
Supplying and fixing stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required (b) Cat B

45

-

-

... More
Supply and erecting fan hook box ( 100 mm diameter or equivalent square size, 75mm deep) fabricated out of 16 SWG sheet steel with 10 m round bar hook bounded to RCC steel upto 50 mm length protruding on each side of the box, including painting with 2 coats of red oxide, complete as required.

45

-

-

... More
L.V PANEL DESIGN 'Fabrication , Supply , Installation , Testing and Commissioning Of Outdoor Main L.V. Panel made out of 14 Swg CRCA sheet , Degreased , derusted and painted with two coats of red oxide primer and two coats of Siemens grey epoxy paint and conforming to IP 54 class of protection . The panel shall be suitable for three phase 415V , 50 Hz. , four wire AC system and shall comprise of the following :Along with necessary stand and earthting brought forward for necesaary connection on both side of panel 'INCOMER'400 amps 4pole,36 KA MCCB, with neutral ,'Sets1'0-500 Volts digital electronic volt meter with selector switch shall be protected by 2 amps TP MCB's.'Sets1'0- 500 Amps digital electronic ammeter with selector switch and 15/5 amps 15 VA, CL 3CTs .'Sets1'Breaker ON / OFF / TRIP indicating lights with control MCB’s.'Set1'RYB Lamp Set1 '3Nos. 600/ 5 amps , 15 VA Class I CT’s.suitable for breaker 'Set1'BUSBAR '600 amps ,415 V TPN 50 Hz Aluminium bus bars with heat shrinkable insulation sleeve.'Set1 ' OUTGOING '100 A 4 Pole MCCB ,36KA 'Se t5 'SPARE FEEDER'200 amps 4 pole MCCB ,36 KA'Set 1 ,'100 amps 4 pole MCCB , 36 KA 'Set1 ,with modem and 3 phase meter as per ged requirement (POWDER COATED )

1

-

-

... More
'Common Area Power Panel 'Fabrication , Supply , Installation , Testing and Commissioning Of COMMON PANEL made out of 14 Swg CRCA sheet , Degreased , derusted and painted with two coats of red oxide primer and two coats of Siemens grey epoxy paint and conforming to IP 54 class of protection . The panel shall be suitable for three phase 415V , 50 Hz. , four wire AC system and shall comprise of the following :Along with necessary stand and earthting brought forward for necesaary connection on both side of panel 'Mains incomer 'INCOMER'160Amps 4 pole MCCB, 25KA SET 1 'Breaker ON / OFF / TRIP indicating lights with control MCB’s.'3 Nos. 200/ 15amps, 15 VA Class I CT’s.digital analog meter SET 1 .'DG incomer '160 Amps 4 pole MCCB, 25KA SET 1 'Breaker ON / OFF / TRIP indicating lights with control MCB’s.SET 1 . 'AUTO CHANGEOVER SWITCHSET 1 '200 amps TPN Auto Changeover switch with standard protectionsSET 1 Phase Indicating lights for both sources with control MCB’s.SET 2 BUSBAR'300 amps 415V,TPN aluminium bus bars with heat shrinkable insulation sleeve.SET 1. 'Outgoing feeder'100 Amps 4 pole MCCB, 25KA SET 1 ,63A FP MCB 25 KA SET 5 ,'40A FP MCB 25 KA SET 3 ',100 Amps 4 pole MCCB 25KA SET 1 'Spare Feeder '63A FP MCB 25 KA SET 3 ,'25 A DP MCB 25 KA SET 1 ,'40 A FP MCB 25 KA SET 1, '16 A SP MCB 25 KA SET 4

1

-

-

... More
Floor panel 'Fabrication , Supply , Installation , Testing and Commissioning made out of 14 Swg CRCA sheet , Degreased , derusted and painted with two coats of red oxide primer and two coats of Siemens grey epoxy paint and conforming to IP 54 class of protection . The panel shall be suitable for three phase 415V , 50 Hz. , four wire AC system and shall comprise of the following :Along with necessary stand and earthting brought forward for necesaary connection on both side of panel 'INCOMER '100 Amps 4 pole MCCB, 25KA SET 1 '0-500 Volts digital electronic volt meter with selector switch shall be protected by 2 amps TP MCB's.SET 1'0- 100 Amps digital electronic ammeter with selector switch and 100/5 amps 10 VA, CL 1 CTs .SET 1'Breaker ON / OFF / TRIP indicating lights with control MCB’s .SET 1'BUSBAR'160 amps 415 V,TPN aluminium bus bars with heat shrinkable insulation sleeve.SET 1'OUTGOING ' PROVISION for Three phase digital Meter SET 5 '25 Amps SP MCB 10K A ,Along With PROVISION for single phase digital Meter SET 1 '25Amps TP MCB 10K A ,

4

-

-

... More
Supplying, erecting, testing and commissioning of diesel generating set with alternator of 60kVA output continuous rating, 3 Phase, 415 V, 50c/s 0.8 p. f. A.C supply, a totally enclosed air cooled / liquid cooled multi-cylinder diesel engine developing suitable BHP at 1500 rpm with 10% overload for 1 hour in 12 hours, along with standard accessories, self-excited, self-regulated, screen protected alternator with static excitation system running at 1500 RPM as per IS 4722-2001 with voltage regulation +/- 5 %, with performance class G2 and maximum fuel consumption 17.4 Ltr/hr @75% loading. Both the engine and alternator direct coupled on a common fabricated steel base frame and mounted on anti-vibrating pads with standard control panel comprising meters, switchgears, indicators connected with suitable wires/cables, the complete set enclosed in composite Acoustic enclosure as fully assembled integral unit made of 16 SWG CRCA Sheet, sound absorbing material to restrict sound level up to 75 dB at 1.0 m, provided with first filling of oil, diesel not less than 100 Ltr etc. on provided M20 Grade CC Foundation as per specification no. GEN-DG

1

-

-

... More
Supplying and erecting integrated LED street light fitting 70-75W IP65 & IK08 class having single piece pressure die-cast aluminium housing, having system lumens output of Min. 7700 Lumens, min. efficacy of 110 lumen/W, CRI70, CCT upto 6500K,THD0.95, operating range of 140-270V, inbuilt surge protection of 10 kV, Life class of 50,000 Hrs. at L70B50, including driver complete with 3 Years warranty as per specification No FG-ODF/FLS2.

7

-

-

... More
Providing & erecting 7 m high (clear height) galvanised octagonal pole with foundation bolts having bottom of 130 mm A/F, top 70 mm A/F on provided foundation as per specification no. OH-PL/OPL

7

-

-

... More
Supplying and erecting Street light bracket for erection of Single fitting made from 40 mm. dia ‘B’ class G.I. pipe 1.0 m. in length along with pole cap of 300 mm length 100 mm dia duly welded as per specification no. FG-BKT/BPC

7

-

-

... More
SITC of Electric Traction Passenger Lift with• Rated capacity :- 8Passenger/540Kg• Floors :- G+1 floor (2Stops/2 Landings)• Travel :- 3 to 4.2 mtrs• Location of Lift Machine:- MR/MRL• Rated speed :- 1.0mps VS• Doors type :- COPO/TOPO Doors with frame having clear opening of 800 mm wide x 2000 mm high made from SS 304 grade sheet of 1.5mm, thick in hairline finish for car and all landing doors with SS door rchitraves/frames• Lift car enclosure made from SS 304 grade sheet of 1.5mm, thick with hairline finish with frame made from MS girders, bracing of adequate size with minimum safety factor of 5, with Toe Guard Apron, with necessary false ceiling with adequate LED lights, blower/fan for ventilation & SS chequered plate flooring, handrails, mirror, emergency light etc.• COP with SS face plate having metallic push buttons with Braille Code & luminous indicator around button with FPI, scrolling UP/DN LED indicator & with/without attendant key switch, OWD with audio-visual alarm, VAS in Marathi, Hindi & English with intercom system with telephone instrument in Lift car, LMR & FCC/ground floor• Clear Car size of ......mm wide x ......mm deep x ......mm high • LOP with SS face plate having recess/surface push button box for all landings with scrolling UP/DN LED indicator having metallic push buttons with Braille Code & luminous indicator around button with CPI, Lift car arrival & next travel direction audio-visual indication at all landings • Lift controller based on microprocessor/ PLC with VVVF Drive having closed loop control system, with IBMS compatible having necessary port, control panel duly wired with proper size & strength copper wire for power & control circuit, with provision for addition of floor/control card & allied accessories control panel having enclosure of 1.5mm CRCA sheet with powder coating with IP54 Protection class • ARD complete with necessary SMF VRLA batteries• Fireman controller having fireman switch at fire Landing,• CCTV surveillance system comprises of 2nos minimum 2.0MP FHD IP based vandal proof Dome camera in lift car & in LMR/inside lift shaft top aimed on Lift machinery & controller with NVR kept in LMR/FCC with HDR data backup for 60 Days with 18" FHD TV monitor, to be kept in FCC/LMR as directed by Engineer In Charge. • Lift Machine of Gearless PMSM of suitable kW with Traction pulley, OSG, electromagnetic brakes, entire assembly mounted on adequate size girders duly fixed on LMR floor/ shaft walls complete with main/diverter traction sheaves, suspension wire ropes/belts of adequate size & strength• Other mechanical parts such as 'T' section adequate size guide rails for car & counter weight with brackets fasteners, counter weight frame with necessary blocks, buffers with necessary support arrangement, MS pit ladder etc. erected with necessary steel work • Minor civil work for alteration if any and erection of door frames and accessories, erection buffers, erection of lift machinery, adequate size core cuts if required & scaffolding for erecting guide rails fixing of girders for mounting lift machine etc. complete as per specification no. LFT.MAHARASHTRA PWD CSR 2018-19, I No: - 17-1-3 Notes 1) General: - Job includes entire procedure of obtaining all necessary erection permissions & "License to Work the Lift" from Electrical Inspector(Lifts) with submission to the Engineer In Charge. 2) Warrantee: - Job covers three years onsite warrantee for all the Lift parts with FCAMC as per the maintenance schedule.

1

-

-

... More
ADD ON for LIFT For Lift having 800mm wide x 2000mm high clear entrance in 1.5mm thick SS 304 grade landing door [Two panel], this includes all necessary accessories like LOP's with UP/DN buttons-arrowsindicators, extension of guide rails, shaft wiring with trunking, traveling cables, main hoisting ropes/belts, & OSG rope landing doors with all accessories etc. necessary for the normal safe functioning of lift installation complete

3

-

-

... More
For Lift car having 800mm wide x 2000mm high clear entrance having 1.5mm thick SS 304 grade sheet car door [Two panel] complete with required accessories like door operator mechanism with drive, required Aluminium sill, infrared curtain & necessary wiring with interlocking arrangement etc. complete

3

-

-

... More
For Full Collective control system, add as below. 1 For Lift travelling above First floor & up to Sixth floor

1

-

-

... More
Supplying, installing, testing and commissioning optical type smoke detector complete on box as per specification no. FFFAS/SD

25

-

-

... More
Supplying, installing, testing and commissioning heat detector complete on box as per specification no. FF-FAS/HD

15

-

-

... More
Supplying, installing, testing and commissioning manual call point (Pill box) with break glass push button in metal enclosure complete as per specification no. FF-FAAS/MCP

5

-

-

... More
Supplying, erecting, testing and commissioning hooters having high (100dB @ 1m) and low (94dB @ 1m) volume setting, group addressing facility allowing multiple sounders to be activated with CRCA enclosure complete as per specification no. FF-FAAS/HTR

10

-

-

... More
Supplying, installation, testing and commissioning of micro processor based intelligent addressable main fire alarm panel, central processing unit with the 4 loop capacity and capable of supporting upto 250 devices and detectors per loop, with on-board LCD display with min 16 lines of text, operating at 230 V 50 HZ - AC with inbuilt Battery Backup of a minimum 24 hours in normal condition and 30 min in alarm condition, suitable provision for network connectivity, interfacing with third party equipment via a MODBUS/ OPC/ L-ON interface etc. conforming to IS 15908:2021, ,IS 2189: 2008, EN 54 & VDS / FM/ UL 864 (10th edition) with 3 years replacement warranty FF-AFAS/CP.

1

-

-

... More
Supplying, erecting, testing and commissioning of 2 core shielded cable complete as per specification no. FF-PA/MCC 1.5 sqmm

500

-

-

... More
Providing coating of bitumen paint & 4mm thick wrapping for underground 150 mm ring main of fire fighting system.

100

-

-

... More
Supplying & erecting automatic control panel for 3 Ph, 415 volt, A.c. Submersible/centrifugal pump set upto 7.5 HP consisting of DOL starter having relay range 9-14 AMP,S.P.P., Combined ammeter/voltmeter, phase indicating lamp enclosed in CRCA powder coated Vibration proof enclosure with IP 54 protection. Control Panel should offer single phasing, phase reversal, phase imbalance etc

2

-

-

... More
Supplying & erecting Water lavel controller 230/ 415V AC., Four way for under ground & Over head tank operation.

1

-

-

... More
Supplying & erecting PVC coated 5 mm dia Brass Sensor/ electrode duly wired with nut & bolts complete

4

-

-

... More
Supplying & erecting Minimum three & above star rated Centrifugal water pump (Monoblock), 415V, three phase 50 cycles A.C. supply of 2.25 KW/3 HP with discharge 600/110 Litres per Minute (LPM) for head of 13/43 m and 65 mm suction/ 50 mm delivery pipe on provided C.C. foundation as per specification No. WP-CGP

2

-

-

... More
Making cement concrete foundation in 1:2:4 cement concrete with foundation bolts and nuts complete. (cost of wooden box is included)(for pumps).

20

-

-

... More
Supplying and installing pressure gauge of 100 mm dia., 0-300 PSI or 0-14 kg per cm square fitted with 12/15 mm dia. pad cock valve, and G.I. pipe, elbow etc. complete as per specification no. FFFFA/PG

2

-

-



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.