Goa State Urban Development Agency Tender

View complete overview of Goa GSUDA Tender

Goa State Urban Development Agency - GSUDA Tender

Works
Civil And Construction
Building Construction
Eprocure
Opening Date4 Mar 2024
Closing Date11 Mar 2024
Tender Amount₹ 1,14,95,449 
Notes
Download

Costs

  • EMD

    ₹ 2,29,910
  • Document Cost

    ₹ 4,000
  • Tender Fee

    ₹ 6,000

Summary

Construction Of Futsal Ground At Madicotto In Land Belonging To Cuncolim Municipal Council

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
Disposal of surplus earth & debris upto all leads and lifts including loading, unloading and stacking, The site should be identified by the contractor and obtain all statuatory approval.

4

-

800

... More
Providing & laying rubble packing with hard laterite stone under floors including watering ramming and consolidating etc.in pipeline trenches and other foundations complete.

102

-

2211

... More
Providing & constructing laterite masonary in neatly dressed stones of size as specified in Cement mortar 1:5 (1cement : 5coarse sand) in foundation and basement.

30

-

5079

... More
Providing & constructing laterite masonary in neatly dressed stones for 23 cms masonary walls in cm. 1:5 (1 cement : 5 coarse sand) in foundation upto plinth level

7

-

5968

... More
Providing & laying cement concrete 1:2:4 (1 cement: 2 coarse sand: 4 graded granitic or basaltic stone aggrt. 20 mm. nominal size) excluding cost of centering, shuttering and finishing in - all works upto plinth level

74

-

6810

... More
Providing and laying upto floor V level cement concrete 1:2:4 (1 cement: 2 coarse sand: 4 graded granitic or basaltic stone aggregate 20 mm nominal size) including smooth finishing to exposed surfaces, with cement mortar 1:3 (1 cement: 3 fine sand) including centering and shuttering etc. - String Courses, copings, bed plates, anchor blocks, plain window sills and the like

4

-

15373

... More
Providing and laying in position (1:1½:3) reinforced cement concrete excluding the cost of centering, shuttering, finishing and reinforcement. (1 cement:1½ coarse sand:3 graded stone agg 20mm nominal size) a) All works upto plinth level

14

-

7178

... More
Providing and laying in position (1:1½:3) reinforced cement concrete excluding the cost of centering, shuttering, finishing and reinforcement. (1 cement:1½ coarse sand:3 graded stone agg 20mm nominal size) b) In walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and structs etc. upto floor five level

9

-

8034

... More
Providing and laying in position (1:1½:3) reinforced cement concrete excluding the cost of centering, shuttering, finishing and reinforcement. (1 cement:1½ coarse sand:3 graded stone agg 20mm nominal size) c) In beams, suspended floors, roofs having slope upto 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases upto floor five level

24

-

8109

... More
Centering and shuttering including strutting, propping etc. and removal of forms for a) foundation, footings, bases of columns etc.

144

-

407

... More
Centering and shuttering including strutting, propping etc. and removal of forms for b) Vertical surfaces such as retaining walls, return walls, Partitions, walls (any thickness) including attached Pilasters, Buttresses, Plinth and string courses, Fillets and the like

352

-

479

... More
Centering and shuttering including strutting, propping etc. and removal of forms for c) Columns, Piers, Pillars, Abutments, Posts and struts (square, rectangle polygon in plan) at all levels

116

-

598

... More
Centering and shuttering including strutting, propping etc. and removal of forms for d) Sides and Soffits of beams, Beam Haunchings, Cantilever, Girders, Bressumers and Lintels plinth beams not exceeding 1m in depth at all levels

138

-

412

... More
Centering and shuttering including strutting, propping etc. and removal of forms for e) suspended floors, roofs, landings, shelves and their supports, balconies and chajjas at all levels

31

-

644

... More
Providing TMT steel reinforcement bars of SAIL, TATA. VIZAG, JSW make only (Confirming to IS 1786 of 1986) for RCC work (conforming to I.S. 1786 of 1986) including bending, binding & placing in position in all the floors along with the factory made precast concrete cover blocks of specified sizes whose compressive strength is not less than that of surrounding concrete in the structural member.

6404

-

105

... More
Supplying and fixing Pre-cast cement concrete kerb-stones(factory made,the factory should be ISO certified and registered under Dirctorate of Industries, Govt. of India) of M-20 with 20 mm nominal size granitic/basaltic aggregate properly consolidated by mechanical plat-form and vibrators with smooth finish including fixing at site complete as per specification. - Size 60 cm L x45 cm H x 15 cm T

2

-

909

... More
Supplying and fixing of Precast RCC slabs(factory made,the factory should be ISO certified and registered under Dirctorate of Industries, Govt. of India) at site in concrete Grade of M-25 with 20 mm nominal size Granitic or basaltic aggregate, consolidated by means of mechanical platform, vibration etc. with lifting hooks of M.s. 10mm bars and PVC cups including cost of reincforcement, Certificate from manufacturer shall be produced indicating grade of concret and minimum content of steel in the product along with 5 year free replacement warranty in case of breakage complete and as directed by Engineer -in -charge. - a) Size 900 x 400 x150 mm with steel reinforcement not less than 7.0 kg per unit - 30T Capacity

188

-

1460

... More
b) Size 750 x 400 x100 mm with steel reinforcement not less than 4.2 kg per unit

350

-

852

... More
Steel work in built up tubular (round, square or rectangular hollow tubes etc.) (Square Hollow Section (SHS) IS4923 /Rectangular Hollow Section (RHS) IS4923/ Circular Hollow Section (CHS) IS1161 closed Structural Steel of approved make (Min Yeild Stress 310 Mpa)) trusses etc., including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete.

12811

-

184

... More
Steel work welded (SAIL, TATA. VIZAG & using electrodes of Ador or ES4B or Deh Secheron make only) in built up sections trusses and framed work including cutting, hoisting, fixing in position and applying priming coat of red lead paint. - In Tees, angles, flats and channels

222

-

130.23

... More
Kotah stone slab flooring over 20 mm (average) thick base laid over & jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing & complete with base of cement mortar 1:4 (1 cement : 4 coarse sand) a) 20mm Thick

27

-

1581

... More
Proving & laying Kotah stone slab over 25 mm thick in risers of steps, skirtings, dado & pillars laid on12mm (average) thick cement mortor 1:3 (1 cement : 3 coarse sand) & jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing & polishing complete.

2

-

1668

... More
Rounding of edges of marble/ Granite / Kotah slab to semi circular slope

60

-

468

... More
Providing and laying factory made Shot blasted cement concrete interlocking paver block of minimum M35 grade made by heavy duty block making machine with strong vibratory compaction and of aprpoved size and design / shape laid in 50 mm thick compacted bed of coarse sand, filling the joints with coarse sand, etc. all complete as per the direction of Engineer.- in I, Wave, Rectangular, Square etc. shapes. The products should comply to IS 15658:2006 and manfucatured by ISO9001: 2008 certified plant. The shot blasting should be done using 0.4-0.5mm dia steel shots with a speed of 3200 rpm.60 mm thick in all colours except grey

248

-

1200

... More
12mm cement plaster 1:4 (1cement: 4 fine sand)

368

-

223

... More
Extra for providing and mixing water proofing material proportion recommended by the manufacturers. b) 12mm cement plaster 1:4 (1 cement : 4 sand)

368

-

8

... More
Applying priming coat with ready mixed primer of approved brand and manufacture on steel work.

832

-

51

... More
Painting two or more coats (excluding priming coat ) with superior quality ready mixed paint for steel work of approved brand and manufacture in all shades on new work to give a even shade

1163

-

107

... More
Painting(two or more coats) with synthetic enamel paint of approved brand and manufacture in all shades on new work over and under coat of suitable shade with ordinary paint of approved brand and manufacture

2

-

161

... More
Painting three or more coats with acryllic exterior paint of approved brand and manufacture (such as Dulex/ Asian Paints/ Sherwin Willians) including applying one coat of cement primer and one coat of surface treatment etc. complete, At all heights from ground level

576

-

208

... More
Painting one or more coats of acryllic exterior paint of approved brand and manufacture(Such as Dulex/ Asian Paints/ Sherwin Willians) on old work including cleaning the surface with water etc. complete.

754

-

114

... More
Repairs to plaster in patches of 2.5 sq.m. and under including cutting the patch in proper shape and preparing and plastering the surface of the walls complete including disposal of rubbish to the dumping ground within 50m lead.

120

-

314

... More
Dismantling old plaster or skirting raking out joints and cleaning the surface for plaster including disposal of rubbish to the dumping ground within 50 mts. lead.

122.5

-

27

... More
Demolishing laterite stone masonry in cement mortar including stacking of serviceable material & disposal of unserviceable material within 50 mts. lead.

2

-

1136

... More
Supply and Laying of 40mm nominal or down granitic/ basaltic aggregates under floors including watering ramming and consolidating etc. complete.

99

-

2555

... More
Supply and Laying of 20mm nominal or down granitic/ basaltic aggregates under floors including watering ramming and consolidating etc. complete.

131

-

2346

... More
Supply and Laying of 10mm nominal or down granitic/ basaltic aggregates under floors including watering ramming and consolidating etc. complete.

50

-

2346

... More
Supply and Laying of Sand (River/ Manufactured) Course/ Fine under floors including watering ramming and consolidating etc. complete. 80% rounded Washed silica sand (particle size 0.2 to 1.0mm)

25

-

2580

... More
Providing and laying non-pressure NP2 class (light duty) RCC pipes with collars jointed with stiff mixture of cement mortar in the proportion of 1:2 (1 cement : 2 fine sand ) including testing of joints, etc. complete.- A) 100 mm dia RCC pipe

25

-

1200

... More
Providing and laying non-pressure NP2 class (light duty) RCC pipes with collars jointed with stiff mixture of cement mortar in the proportion of 1:2 (1 cement : 2 fine sand ) including testing of joints, etc. complete.- B) 250 mm dia RCC pipe

25

-

2034

... More
Providing and fixing Rigid PVC (SELFIT) pipes for public water supply including Railway freight, carting, loading and unloading, stacking, transit insurance etc, conforming to ASTM 2467 with ISO 14001, including all PVC plain & threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step PVC solvent cement and testing of joints complete as per direction of Engineer.conforming to IS 4985-2000 and bearing ISI mark, CLASS 10 KG/ SQ. CM - Outer dia 110 mm

253

-

1012

... More
Extra for perforations for 110mm PVC pipe of class 10 kg/Sq. Cm. Staggered perforations of 25mm diameter at every 150mm interval and 50mm spacing across a curvature of 160degree.

253

-

75

... More
Providing and fixing G.I. chain link mesh 6.35cm x 6.35 cm x 10 gauge (2.5” x 2.5” x 10 gauge) fixed with angle iron posts and struts by G.I. or M.S. staples at 20cms apart with welding with the iron posts (placed at 3 meters centre to centre) complete as per the direction of the Engineer – in – charge (angle iron posts struts, earthwork and concrete for fencing posts and struts to be paid separately)

832

-

265

... More
Providing & laying of FIFA QUALITY approved synthetic football turf surface pile height 50mm thick with 100% Polyethylene fibres (monofilament straight fibres, 350-370 micron thickness, 13000-13500 dtex, tufted) over existing sub base including marking on the surface complete as per FIFA Specifications. Including joined/sewn seams, turf saturation with minimum 16-17 kg per m2 of Washed silica sand (paid separately) and minimum 17-19 kg per m2 SBR granular infil according to manufacturers' specifications, infill levels no less than 75% yarn height including combing the field, inlaying of all lines with white yarn complete. Roll width to be minimum 3.95m and length as per layout. The Tuft cloth to be UV-Stabilized Polypropelene with backing of Latex 1000 gr/m² Complete. (supplier should be FIFA preferred Producer)

986

-

1991

... More
Suppying and placing in position mechanically bonded nonwoven geotextile 200 gsm made of virgin high tenacity polypropylene staple fibers which are UV stabilized. It should be characterized by a high resistance to installation damage, high water permeability, resistance to ultraviolet degradation and to biological & chemical environments normally found in soils. This separation barrier should cover entire field including the edges & perimeter drains. There should be overlap between panels (laid area will be measured, laps will not be paid separately)

1239

-

120

... More
Providing & Fixing in position Metal Goal Post (Dimensions Width/Depth/Ø80 mm) for Futsal as per FIFA QUALITY Standards. Each set of Goal Post will consist on 2 verticals with horizontal distance between inside of the posts 3.00m and 1 Horizontal with vertical distance from the lower edge of the crossbar to the ground 2.00m. Goal nets fixed without metal hooks. The depth of the goal from the inside part of the goalposts and facing the court must be at least 80cm at the top part and 100cm at the bottom including powder coating. Sprung loaded foot operated 32mm dia folding frame for easy storage & steel bottom bar including civil works complete. (1 set is complete goal post set on one side of playing field)

2

-

30000

... More
Supply of 3 1/2 core armoured PVC/XLPE insulated, PVC sheathed aluminium conductor cable of 1.1 KV grade with ISI mark conforming to IS:1554 (Part I) ,IS:7098(Part I) with latest amendments of following size. - 3 1/2 Core 25 sq.mm

100

-

348

... More
Supply of 4 core armoured PVC/XLPE insulated, PVC sheathed copper conductor cable of 1.1 KV grade with ISI mark conforming to IS:1554(Part I) ,IS:7098(Part I) with latest amendments of following size. - 4 Core 4 sq.mm

250

-

413

... More
Supply of 4 core armoured PVC/XLPE insulated, PVC sheathed copper conductor cable of 1.1 KV grade with ISI mark conforming to IS:1554(Part I) ,IS:7098(Part I) with latest amendments of following size. - 4 Core 2.5 sq.mm

25

-

285

... More
Supply of 2 core unarmoured PVC/XLPE insulated, PVC sheathed copper conductor cable of 1.1 KV grade with ISI mark conforming to IS:1554(Part I) ,IS:7098(Part I) with latest amendments of following size :- 2 Core 1.5 sq.mm

180

-

99

... More
Supplying and making cable end terminations with brass compression gland and aluminium lugs for folowing sizes of 3 1/2 Core PVC insulated PVC sheathed/XLPE aluminium conductor cable of 1.1 KV grade, complete as required. (1) 3 1/2 x 25 Sq. mm.

2

-

383

... More
Supplying and making cable end terminations with brass compression gland and copper lugs for folowing sizes of 4 Core PVC insulated PVC sheathed/XLPE aluminium conductor cable of 1.1 KV grade, complete as required. - 4 x 4 Sq. mm.

40

-

284

... More
Supplying and making cable end terminations with brass compression gland and copper lugs for folowing sizes of 4 Core PVC insulated PVC sheathed/XLPE aluminium conductor cable of 1.1 KV grade, complete as required. - 4 x 1.5/2.5 Sq. mm.

2

-

236

... More
Supply and making cable end terminations with compression gland and copper lugs for following sizes of PVC insulated PVC sheathed/XLPE aluminium conductor cable of 1.1 KV grade, complete as required. 2 x 1.5/2.5 Sq. mm.

20

-

206

... More
Laying of one number PVC insulated and PVC sheathed/XLPE power cable of 1.1 KV grade of size not exceeding 25 sq.mm direct in ground including excavation in the form of a trench as per Cable Trench Drawing provided by the Engineer-Incharge,sand cushioning with screened sand bed of 20mm thick , protective covering with bricks placed breadth-wise on top of cable all over the run( the brick protection shall cover the cable and project atleast 5 cms over the sides of the cable) and backfilling the excavated earth without stones or hard material and making the surface proper with 15 cm crown on the top complete as required.- Rocky Strata

80

-

505

... More
Laying of one number additional PVC insulated and PVC sheathed/XLPE power cable of 1.1 KV grade of size not exceeding 25 sq.mm direct in ground in the same trench in one tier horizontal formation including excavation in the form of a trench as per Cable Trench Drawing provided by the Engineer-Incharge,sand cushioning with screened sand bed of 20mm thick , protective covering with bricks placed breadth-wise on top of cable all over the run( the brick protection shall cover the cable and project atleast 5 cms over the sides of the cable) and backfilling the excavated earth without stones or hard material and making the surface proper with 15 cm crown on the top complete as required - Rocky Strata

240

-

332

... More
Laying of one number PVC insulated and PVC sheathed/XLPE power cable of 1.1 KV grade of size not exceeding 25 sq.mm in the existing masonry open duct, etc. complete as required

235

-

40

... More
Earthing with GI earth plate 600 mm x 600 mm x 6 mm thick including accessories and providing masonry enclosure with CI/RCC cover having locking/Lifting arrangement and watering pipe etc. (but without charcoal or coke and salt) as required as per the Earthing Drawing provided by the Engineer-Incharge.The scope of work includes the following: a) Excavation of pit of size 1.0x1.0x 3.0 mtrs(min) and disposal of excavated soil. c)Watering GI pipe, 20mm, Class B, with funnel as per specs. d) Charcoal/salt as per specs ( paid seperately). e) Refilling the pit of size 1.0x1.0x 3.0 mtrs(min) with soft black agriculture soil of minimum resistivity i/c transportation. e) Masonary chamber with proper foundation, cover plate and locking arrangement. f) Testing of earth value with earth megger and certifications of its value. Aluminium tag with embossed earthing value to be attached to the pipe.g)watering arrangement(plumbing will be paid seperately). (a) In rocky strata

2

-

10403

... More
Earthing with GI earth pipe 2 mts long 40 mm dia medium class with ISI mark, of approved brands including accessories and providing masonry enclosure with CI/RCC cover having locking /Lifting arrangement and watering pipe etc. (but without charcoal or coke and salt) as required as per the Earthing Drawing provided by the Engineer-Incharge.The scope of work includes the following: a) Excavation of pit of size not less than 1.0x1.0x 2.0 mtrs(min) and disposal of excavated soil. b) Class B GI pipe, 40mm diameter as per specifications. c) Charcoal/salt as per specs ( paid seperately). d) Refilling the pit of size not less than 1.0x1.0x 2.0 mtrs(min) with soft black soil of minimum resistivity i/c transportation. e)Masonary chamber with proper foundation, cover plate and locking arrangement. f) Testing of earth value with earth megger and certifications of its value. Aluminium tag with embossed earthing value to be attached to the pipe . g)watering arrangement(plumbing will be paid seperately). (a) In rocky strata

4

-

6760

... More
Extra for using salt and charcoal for GI or copper plate earth electrode as required (96 Kgs of Charcoal and 5 Kgs of Salt)

6

-

1861

... More
Supplying and laying 25 mm x 5 mm GI strip at 0.5 m below ground as strip earth electrode including soldering etc. as required

15

-

216

... More
Supplying and laying 25 mm x 5 mm GI strip in 40 mm dia GI pipe from earth electrode as required

18

-

464

... More
Providing and fixing 25 mm x 5 mm GI strip on surface or in recess for connections etc. as required

15

-

281

... More
Supplying and laying 6 SWG GI wire at 0.5 m below ground level for conductor earth electrode including soldering etc. as required

300

-

58

... More
Making M- 20 grade reinforced cement concrete foundation by considering the safe soil bearing capacity at site as 10 T/sq.m at 1.5 m depth including supply of steel, concrete, excavation and fixing provided nut bolts with the help of template, duly plastered as per design complete (for 9m & 10m high octagonal /conical GI pole).

10

-

4904

... More
Providing & erecting 10 m high (clear height) galvanised octagonal pole with foundation bolts having bottom of 175 mm A/F, top 70 mm A/F on provided foundation as per specification no. OH-PL/OPL

10

-

24662

... More
Supplying and erecting integrated LED flood light fitting Max. 195W IP65 & IK07 class having pressure die-cast aluminium housing, having system lumens output of Min. 23400 Lumens, min. efficacy of 120 lumen/W, CRI70, CCT upto 6500K, THD10%, p.f. 0.90, operating range of 140-270V, inbuilt surge protection of 4 kV, Life class of 50,000 Hrs. at L70B50, including driver with U shaped bracket with 3 Years warranty as per specification No FG-ODF/FLS2.

20

-

15846

... More
Supplying and erecting water tight terminal box of 1.6mm thick ( 16 gauge ) CRCA sheet of size 200 x 150 x 150 mm complete on pole as per speciffication no CB-SB

20

-

482

... More
Supply, Fabrication, Erection, Testing and Commissioning of Main Panel floor mounted with frame of suitable M.S channel dully painted, fabricated of 14/16 swg CRCA sheets completely derusted, chemically treated and powder coated with shade suggested by client and having following items as per single line diagram:- 40A, 10KA, TP MCB - 1 no. wired for KWH meter ( 3 ph) with 100A, 4P aluminium bus bar with outgoing feeders of 6-32A, 10KA, TP, MCB 4 nos complete as per single line drawing of MLTP

1

-

46648



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.