Electricity Department Tender

View past bidders for Goa Electricity Department Tender

Electricity Department Tender

Works
Electrical Generators And Transformers
Electrical and Electronics
Eprocure
Opening Date21 Apr 2025
Closing Soon2 May 2025
Tender Amount₹ 13,35,588 
Notes
Download

Costs

  • EMD

    ₹ 26,712
  • Document Cost

    ₹ 1,500
  • Tender Fee

    ₹ 2,671

Summary

Work Of Erection Of 100kva Transformer Centre To Cater Additional Load Of St.philip And James Church, Cortalim In The Jurisdiction Of S/d-ii(r), Div Xi, Vasco.

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
Supply of HDGI 2 pin 'X' arm of 75 x 40 Channel as per the drawing No.CEE/E/704 as per annexure confirming to IS- 2633/72 or the latest version thereof

5

569

2845

... More
Supply of HDGI 4 pin 'X' arm of 75 x 40 Channel as per the drawing No.CEE/E/705 as per annexure confirming to IS- 2633/72 or the latest version thereof.

5

1109

5545

... More
Supply of HDGI Cut point of 75 x 40 x 7.3 mm Channel 1.3 Mtr long as per the drawing No EE/IV/11 KV/X-Arms as per annexure confirming to IS - 2633/72or the latest version thereof

3

1959

5877

... More
Supply of HDGI 11 KV V-shape 'X' arm of 75 x 40 x 7.3 mm channel as per the drawing No.CEE/E-408 as per annexure confirming to IS-2633/72 or the latest version thereof

4

1469

5876

... More
Supply of HDGI Guard of 75 x 40 x 7.3 mm Channel of 1.5 Mts long as per annexure confirming to IS -2633/72or the latest version thereof

5

2196

10980

... More
Supply of HDGI X arm clamps for RCC Pole 11.00 mtr L.A as per the drawing No.CEE/E-711 as per annexure confirming to IS- 2633/72 or the latest version thereof

12

414

4968

... More
Supply of HDGI st. light clamps for 40 mm pipe (top/bottom) for 11 Mtrs RCC Pole

10

502

5020

... More
Supply HDGI stay clamps for RCC Pole 11.00 Mts L.A.as per the drawing No.CEE/E-711 as per annexure confirming to IS- 2633/72 or the latest version thereof

6

621

3726

... More
Supply of HDG.I. stay wire 7/10 SWG conforming to IS-2141/1979 grade- I, IS:4826-1979 & IS:6594-1974 or latest version thereof with tensile grade 4 & having minimum tensile strenght of 700N/mm2 conforming to IS:2141 or the latest version thereof

28.5

141

4018.5

... More
Supply of H.D.G.I. stay rod of 1200mm long and 16mm dia with an eye band of internal dia 40mm at one end and threaded up to length of 200mm at the other end galvanised. H.D.G.I.stay plate of 450x450x8mm size with a hole drilled at the centre to suit 16mm dia GI rod galvanised.as per the drawing No. CEE/E-465

6

2404

14424

... More
Supply of G.I. Turn Buckle with eye bolt 11 KV as per the drawing No. CEE/E-466

6

677

4062

... More
Supply of Break insulators 8 KV (44KN) as per the drawing No. CEE/E-425 as per annexure confirming to the IS:5300-1969 or the latest version thereof

6

176

1056

... More
Supply of G.I. Nuts & Bolts as per annexure confirming to the IS- 2633/72 or the latest version thereof

18

228

4104

... More
Supply of 11 KV brown glazed ball and socket type disc insulators as per the drawing No. CEE/E-128 conforming to IS:2486 Pt No.1 to 4 and type 46 of IS-3188/80 as ammended upto date for a minimum failing load of 45KN with minimum creepage distance of 320 mm with16mm ball and socket alternative `B'

9

1152

10368

... More
Supply of Metal parts for 11 KV disc 45 KN, 3 bolted type as per IS-2486 part - II& III /1974 as ammended upto date& 3 `U' bolted type tension/ suspension clamp.

9

1213

10917

... More
Supply of 11 KV Brown glazed pin insulator having minimum failing load of 10KN in tranverse direction & 45KN applied axially. The minimum creepage distance shall be of 320 mm conforming to type B of IS:731/71 & IS:3188 as ammended from time to time. The dimensions of the 11KV pin insulator will be as per drawing no. EE VI 01

9

454

4086

... More
Supply G.I. Pin for 11 KV Pin Insulators shall be H.D.G.I. small steel head type S 165 P as per IS:2486(Part-I & II) having stalk lenght of 165 mm and shank lenght of 150mm with a minimum failing load of 10KN. The dimensions of the 11KV pin insulator will be as per drawing no. EE VI 01

9

239

2151

... More
Supply of HDGI top fitting for LT/11 KV RCC pole as per the drawing No. EE/X/TRN/DR6 2/4 as per annexure confirming to IS- 2633/72 or the latest version thereof

9

268

2412

... More
Supply of LT brown glazed shackle Insulator of size 100 mm x 115 mm conforming to fig No. 4 and type 2 fo IS: 1445/77 as amended upto date. Minimum failing load shall be 16 KN with GI hardware suitable for LT shackle insulator of size 100 x 115 mm conforming to type 2 fig 4 of IS: 1445/77 as amended upto date as per the drawing No.EE/X/TRN/DRG1/2.

30

167

5010

... More
Supply Metal parts for L.T. Shackle insulators or the Strap type fittings shall consists of a pair of H.D.G.I. straps, 2nos. H.D.G.I. bolts with hexagonal head & nuts, 2 nos. H.D.G.I. spring washers, & helically formed conductor dead-end fittings made of aluminium alloy or aluminium-clad steel conforming to the relevant IS specifications as per the drawing No.EE/X/TRN/DRG1/2.

30

205

6150

... More
Supply L.T. brown glazed porcelain pin insulators of size 100mmx70mm conforming to type 1 fig 1 of IS: 1445/1977 with amendment 2 of Feb 1981 (second revision) as amended upto date as per the drawing No.CEE/E-814 with Minimum failing load shall be 3.5 KN.

10

136

1360

... More
Supply G.I. Pin for L.T.Pin Insulators conforming to IS 7935/1975 as amended upto date suitable for LT porcelain pin insulator type 1 conforming to fig 1 of IS: 1445/77 with amendment no 2 feb 1981, of size 100 x 70 mm. GI pin shall comprise of GI nut and spring washer and conform to fig No 2 of IS: 7935/1975. Minimum failing load of pin shall be 3.5 KN L.T. Pin Insulators

10

127

1270

... More
Supply of AAC 'ANT' Conductor, hard drawn stranded aluminium conductor & conforming to IS:398(Pt-I/76) with ammendment no. 1,2 & 3 & of size 7/3.10mm aluminium, (nominal aluminium area 50mm)

0.55

60500

33275

... More
Supply of AAC 'GNAT' Conductor, hard drawn stranded aluminium conductor & conforming to IS:398(Pt-I/76) with ammendment no. 1,2 & 3 & of size 7/2.21mm aluminium, (nominal aluminium area 25mm2)

0.55

31000

17050

... More
Supply of Hard drawn stranded aluminium conductor galvanized steel reinforced & conforming to IS:398(Pt-II/96) with amendment no. 1 & 3 & of size 6/2.59 mm aluminium, 1/2.59 mm steel wire "WEASEL"

0.45

40100

18045

... More
Supply of PVC insulated single core cable 50 mm2 for D.P. earthing

50

135

6750

... More
Supply of 11 KV rated voltange GOAB switches tilting type, outdoor, manually operated, triple pole, single break, conforming toIS-9921 (Part-I to IV) [ 1981 - 85] as amended up to date and detailed specification eclosed herewith. Each set shall comprise of six pedestal and three tilting post insulators. Insulator should be factory cemented by the manufacturer of the insulators and have minimum 320 mm creepage distance and AB switchs contacts shall be of copper/ copper alloy. The AB switch shall be of following current rating: 200 A

1

23535

23535

... More
Supply of 9 KV, 5 KA nominal discharge current metal oxide gapless distribution class Lightning arrestor conforming to IEC-600994-4 and IS: 3070 part 3 1993 as amended upto date suitable for 11 KV 50 HZ effectively earthed neutral system with necessary mounting arragements and connector suitable to connect ASCR conductor upto overall diameter 12.30 mm

3

3033

9099

... More
Supply of 11 KV , 200 A Horn gap fuse unit (Set of three) shall be as per drg No. CEE/E-786 as per annexure confirming toI.S. 2062,IS: 1367,IS: 4218,IS: 1363,IS-209 1979 or the latest version thereof

1

10450

10450

... More
Supply of MS Distribution box as per drg No. CEE/E-689 Revision No. 2 along with MCCB 400 A, Bus bar made out of Aluminium strips 40 x 10 mm, Other accessories & 200 Amps, Porcelain KitKat Fuse Carrier & Base with extended terminals shall be as per drawing No.CEE/E/543-Rev 4 (Set of 3) for 4 feeder arrangement with 1 no of moulded case circuit breaker (MCCB) of 400A, 415V, AC 50 Hz for 100 KVA Distribution Transformer centre

1

63140

63140

... More
Supply Enamelled Danger board 400V of size 250mm x 200 mm as per the drawing No. CEE/E-490.

5

248

1240

... More
Supply of Anticlimbing deviceas per the drawing No. CEE/E-478.

5

962

4810

... More
Supply of HDGI DP Structural material shall include :-a) GI channel ISMC 75x40x7.3mm 2.75 mtrs long 2 pieces for incoming line & installation of disc insulators b) GI channel ISMC75x40x7.3mm 2.75mtrs long 2 pieces for GOAB switch c) GI channel ISMC 75x40x7.3mm 2.75 mtrs long 2 pieces for HG fuses d) GI channel ISMC 75x40x7.3mm 2.75 mtrs long 2 pieces for installation of lightening arrestor e) GI channel ISMC 100x50x7.3mm 2.75 mtrs long 2 pieces for installation of Trasformer f) GI channel ISMC 75x40x7.3mm 2.75 mtrs long 2 pieces for side support of trasformer g) GI channel ISMC 75x40x7.3mm 2.75 mtrs long 4 pieces for installation of any other items h) GI channel ISMC 100x40x7.3mm 0.52 mtrs long 2 pieces for installation of Transformer base channel

380

169

64220

... More
Earthing complete comprises of H.D.G.I. Pipe of class B length 2.5 mts , 40mm nominal bore(outside diameter 48.8mm maximum and 47.9mm minimum ,thickness4.0mm and mass of tube plain end 4.37kg/m) conforming to IS1239 Part 1 1990 asamended upto date and hot dip zinc coating shall conform to IS 4736 as ACSR'Weasel' Conductor( quantity as required) , pit filled with homogeneous layer of20 kgs of charcoal, sand and salt as per the drawing No. CEE/E-829

8

2730

21840

... More
FRP Fencing Complete with Gate as per specifcation for Distribution Transformer (Size 6MX3MX2M) with Concreting for FRP Fencing supports with plinth (03x0.3x0.5) Cu.m. x 18 nos. Each ratio 1:3:6

1

108770

108770

... More
Supply of XLPE Single Core unarmoured 300 sq mm,cross linked polyethelene insulated, PVC shealthed 1 core 300 sqmm cable 1.1.KV gradesuitable for 3 phase earthed system and conforming to IS: 7098 (Part-I)/1988 as amended upto date.

40

555

22200

... More
Supply of Three and half core armoured XLPE cable of size 120 Sq.mm cross linked polyethelene insulated, PVC shealthed 3.5 core 120 sqmm cable with galvanized steel strip armoured aluminium cable of 1100 volts grade suitable for 3 phase earthed system and conforming to IS: 7098 (Part-I)/1988 as amended upto date.

50

945

47250

... More
Supply of Aluminium crimping Lugs shall conform to IS: 8309-1976 as amended upto date. Lugs shall be made of aluminium of grade IE of IS: 5082/1969 suitable for aluminium cable of 300 sq.mm

8

124

992

... More
Supply of Aluminium crimping Lugs shall conform to IS: 8309-1976 as amended upto date. Lugs shall be made of aluminium of grade IE of IS: 5082/1969 suitable for aluminium cable of 120 sq.mm

12

54

648

... More
Supply of DTC Metering Unit

1

25688

25688

... More
Supply and Installation of Modem for Automatic Meter Reading

1

6000

6000

... More
Feeder issolation and replacement of damaged HT pole on the existing sancoale cortalim feeder in the vicinity of new DTC

-

-

-

... More
Supply of RCC pole 11 mtr as per the drawing No.CEE/E-698 REV-3 as per annexure confirming to IS 785-1998 as amended upto date. The component used for pole shall conform to following IS amended up to date. 1) Ordinary Port land cement 53 grade IS 12269 2) Aggregate IS 383-1970 3) Torsteel IS 1786-7985 4) MS bar IS 432 p 1 & 2-1982

4

16371

65484

... More
Supply of HDGI 2 pin 'X' arm of 75 x 40 Channel as per the drawing No.CEE/E/704 as per annexure confirming to IS- 2633/72 or the latest version thereof

4

569

2276

... More
Supply HDGI 4 pin 'X' arm of 75 x 40 Channel as per the drawing No.CEE/E/705 as per annexure confirming to IS- 2633/72 or the latest version thereof.

4

1109

4436

... More
Supply HDGI Cut point of 75 x 40 x 7.3 mm Channel 1.3 Mtr long as per the drawing No EE/IV/11 KV/X-Arms as per annexure confirming to IS - 2633/72or the latest version thereof

2

1959

3918

... More
Supply HDGI 11 KV V-shape 'X' arm of 75 x 40 x 7.3 mm channel as per the drawing No.CEE/E-408 as per annexure confirming to IS-2633/72 or the latest version thereof

4

1469

5876

... More
SupplyHDGI Guard of 75 x 40 x 7.3 mm Channel of 1.5 Mts long as per annexure confirming to IS -2633/72or the latest version thereof

5

2196

10980

... More
Supply HDGI X arm clamps for RCC Pole 11.00 mtr L.A as per the drawing No.CEE/E-711 as per annexure confirming to IS- 2633/72 or the latest version thereof

12

414

4968

... More
Supply HDGI stay clamps for RCC Pole 11.00 Mts L.A.as per the drawing No.CEE/E-711 as per annexure confirming to IS- 2633/72 or the latest version thereof

6

621

3726

... More
Supply of HDG.I. stay wire 7/10 SWG conforming to IS-2141/1979 grade- I, IS:4826-1979 & IS:6594-1974 or latest version thereof with tensile grade 4 & having minimum tensile strenght of 700N/mm2 conforming to IS:2141 or the latest version thereof

9.5

141

1339.5

... More
Supply of H.D.G.I. stay rod of 1200mm long and 16mm dia with an eye band of internal dia 40mm at one end and threaded up to length of 200mm at the other end galvanised. H.D.G.I.stay plate of 450x450x8mm size with a hole drilled at the centre to suit 16mm dia GI rod galvanised.as per the drawing No. CEE/E-465

2

2404

4808

... More
Supply of G.I. Turn Buckle with eye bolt 11 KV as per the drawing No. CEE/E-466

2

677

1354

... More
Supply of Break insulators 8 KV (44KN) as per the drawing No. CEE/E-425 as per annexure confirming to the IS:5300-1969 or the latest version thereof

2

176

352

... More
Supply of G.I. Nuts & Bolts as per annexure confirming to the IS- 2633/72 or the latest version thereof

6

228

1368

... More
Supply of 11 KV brown glazed ball and socket type disc insulators as per the drawing No. CEE/E-128 conforming to IS:2486 Pt No.1 to 4 and type 46 of IS-3188/80 as ammended upto date for a minimum failing load of 45KN with minimum creepage distance of 320 mm with16mm ball and socket alternative `B'

12

1152

13824

... More
Supply of Metal parts for 11 KV disc 45 KN, 3 bolted type as per IS-2486 part - II& III /1974 as ammended upto date& 3 `U' bolted type tension/ suspension clamp.

12

1213

14556

... More
Supply of 11 KV Brown glazed pin insulator having minimum failing load of 10KN in tranverse direction & 45KN applied axially. The minimum creepage distance shall be of 320 mm conforming to type B of IS:731/71 & IS:3188 as ammended from time to time. The dimensions of the 11KV pin insulator will be as per drawing no. EE VI 01

9

454

4086

... More
Supply G.I. Pin for 11 KV Pin Insulators shall be H.D.G.I. small steel head type S 165 P as per IS:2486(Part-I & II) having stalk lenght of 165 mm and shank lenght of 150mm with a minimum failing load of 10KN. The dimensions of the 11KV pin insulator will be as per drawing no. EE VI 01

9

239

2151

... More
Supply of HDGI top fitting for LT/11 KV RCC pole as per the drawing No. EE/X/TRN/DR6 2/4 as per annexure confirming to IS- 2633/72 or the latest version thereof

9

268

2412

... More
Supply of LT brown glazed shackle Insulator of size 100 mm x 115 mm conforming to fig No. 4 and type 2 fo IS: 1445/77 as amended upto date. Minimum failing load shall be 16 KN with GI hardware suitable for LT shackle insulator of size 100 x 115 mm conforming to type 2 fig 4 of IS: 1445/77 as amended upto date as per the drawing No.EE/X/TRN/DRG1/2.

18

167

3006

... More
Supply of Metal parts for L.T. Shackle insulators or the Strap type fittings shall consists of a pair of H.D.G.I. straps, 2nos. H.D.G.I. bolts with hexagonal head & nuts, 2 nos. H.D.G.I. spring washers, & helically formed conductor dead-end fittings made of aluminium alloy or aluminium-clad steel conforming to the relevant IS specifications as per the drawing No.EE/X/TRN/DRG1/2.

18

205

3690

... More
Supply of L.T. brown glazed porcelain pin insulators of size 100mmx70mm conforming to type 1 fig 1 of IS: 1445/1977 with amendment 2 of Feb 1981 (second revision) as amended upto date as per the drawing No.CEE/E-814 with Minimum failing load shall be 3.5 KN.

10

136

1360

... More
Supply of G.I. Pin for L.T.Pin Insulators conforming to IS 7935/1975 as amended upto date suitable for LT porcelain pin insulator type 1 conforming to fig 1 of IS: 1445/77 with amendment no 2 feb 1981, of size 100 x 70 mm. GI pin shall comprise of GI nut and spring washer and conform to fig No 2 of IS: 7935/1975. Minimum failing load of pin shall be 3.5 KN L.T. Pin Insulators

10

127

1270

... More
Supply and Stringing of AAC 'ANT' Conductor, hard drawn stranded aluminium conductor & conforming to IS:398(Pt-I/76) with ammendment no. 1,2 & 3 & of size 7/3.10mm aluminium, (nominal aluminium area 50mm)

0.4

60500

24200

... More
Supply of AAC 'GNAT' Conductor, hard drawn stranded aluminium conductor & conforming to IS:398(Pt-I/76) with ammendment no. 1,2 & 3 & of size 7/2.21mm aluminium, (nominal aluminium area 25mm2)

0.4

31000

12400

... More
Supply of Hard drawn stranded aluminium conductor galvanized steel reinforced & conforming to IS:398(Pt-II/96) with amendment no. 1 & 3 & of size 6/2.59 mm aluminium, 1/2.59 mm steel wire "WEASEL"

0.4

40100

16040

... More
Supply of 11 KV rated voltange GOAB switches tilting type, outdoor, manually operated, triple pole, single break, conforming toIS-9921 (Part-I to IV) [ 1981 - 85] as amended up to date and detailed specification eclosed herewith. Each set shall comprise of six pedestal and three tilting post insulators. Insulator should be factory cemented by the manufacturer of the insulators and have minimum 320 mm creepage distance and AB switchs contacts shall be of copper/ copper alloy. The AB switch shall be of following current rating: 200 A

2

23535

47070

... More
Supply of 9 KV, 5 KA nominal discharge current metal oxide gapless distribution class Lightning arrestor conforming to IEC-600994-4 and IS: 3070 part 3 1993 as amended upto date suitable for 11 KV 50 HZ effectively earthed neutral system with necessary mounting arragements and connector suitable to connect ASCR conductor upto overall diameter 12.30 mm

3

3033

9099

... More
Supply of Enamelled Danger board 400V of size 250mm x 200 mm as per the drawing No. CEE/E-490.

4

248

992

... More
Supply of Anticlimbing deviceas per the drawing No. CEE/E-478.

4

962

3848

... More
COST OF ERECTION AND REMOVING

-

-

-

... More
Erection of RCC pole 11 mtr as per the drawing No.CEE/E-698 REV-3 as per annexure confirming to IS 785-1998 as amended upto date. The component used for pole shall conform to following IS amended up to date. 1) Ordinary Port land cement 53 grade IS 12269 2) Aggregate IS 383-1970 3) Torsteel IS 1786-7985 4) MS bar IS 432 p 1 & 2-1982

5

9800

49000

... More
Erection of RCC pole 9 mtr as per the drawing No.CEE/E-698 REV-3 as per annexure confirming to IS 785-1998 as amended upto date.

3

5900

17700

... More
Erection of HDGI 2 pin 'X' arm of 75 x 40 Channel as per the drawing No.CEE/E/704 as per annexure confirming to IS- 2633/72 or the latest version thereof

5

232

1160

... More
Erection of HDGI 4 pin 'X' arm of 75 x 40 Channel as per the drawing No.CEE/E/705 as per annexure confirming to IS- 2633/72 or the latest version thereof.

5

261

1305

... More
Erection of HDGI Cut point of 75 x 40 x 7.3 mm Channel 1.3 Mtr long as per the drawing No EE/IV/11 KV/X-Arms as per annexure confirming to IS - 2633/72or the latest version thereof

3

492

1476

... More
Erection of HDGI 11 KV V-shape 'X' arm of 75 x 40 x 7.3 mm channel as per the drawing No.CEE/E-408 as per annexure confirming to IS-2633/72 or the latest version thereof

4

338

1352

... More
Erection of HDGI Guard of 75 x 40 x 7.3 mm Channel of 1.5 Mts long as per annexure confirming to IS -2633/72or the latest version thereof

5

546

2730

... More
Erection of HDGI X arm clamps for RCC Pole 11.00 mtr L.A as per the drawing No.CEE/E-711 as per annexure confirming to IS- 2633/72 or the latest version thereof

12

65

780

... More
Erection of HDGI st. light clamps for 40 mm pipe (top/bottom) for 11 Mtrs RCC Pole

10

47

470

... More
Erection HDGI stay clamps for RCC Pole 11.00 Mts L.A.as per the drawing No.CEE/E-711 as per annexure confirming to IS- 2633/72 or the latest version thereof

6

98

588

... More
Erection of HDG.I. stay wire 7/10 SWG conforming to IS-2141/1979 grade- I, IS:4826-1979 & IS:6594-1974 or latest version thereof with tensile grade 4 & having minimum tensile strenght of 700N/mm2 conforming to IS:2141 or the latest version thereof

28.5

62

1767

... More
Erection of H.D.G.I. stay rod of 1200mm long and 16mm dia with an eye band of internal dia 40mm at one end and threaded up to length of 200mm at the other end galvanised. H.D.G.I.stay plate of 450x450x8mm size with a hole drilled at the centre to suit 16mm dia GI rod galvanised.as per the drawing No. CEE/E-465

6

1779

10674

... More
Erection G.I. Turn Buckle with eye bolt 11 KV as per the drawing No. CEE/E-466

6

267

1602

... More
Erection of Break insulators 8 KV (44KN) as per the drawing No. CEE/E-425 as per annexure confirming to the IS:5300-1969 or the latest version thereof

6

97

582

... More
Erection of G.I. Nuts & Bolts as per annexure confirming to the IS- 2633/72 or the latest version thereof

18

30

540

... More
Erection 11 KV brown glazed ball and socket type disc insulators as per the drawing No. CEE/E-128 conforming to IS:2486 Pt No.1 to 4 and type 46 of IS-3188/80 as ammended upto date for a minimum failing load of 45KN with minimum creepage distance of 320 mm with16mm ball and socket alternative `B'

9

154

1386

... More
Erection of Metal parts for 11 KV disc 45 KN, 3 bolted type as per IS-2486 part - II& III /1974 as ammended upto date& 3 `U' bolted type tension/ suspension clamp.

9

178

1602

... More
Erection of 11 KV Brown glazed pin insulator having minimum failing load of 10KN in tranverse direction & 45KN applied axially. The minimum creepage distance shall be of 320 mm conforming to type B of IS:731/71 & IS:3188 as ammended from time to time. The dimensions of the 11KV pin insulator will be as per drawing no. EE VI 01

9

76

684

... More
Erection G.I. Pin for 11 KV Pin Insulators shall be H.D.G.I. small steel head type S 165 P as per IS:2486(Part-I & II) having stalk lenght of 165 mm and shank lenght of 150mm with a minimum failing load of 10KN. The dimensions of the 11KV pin insulator will be as per drawing no. EE VI 01

9

76

684

... More
Erection of HDGI top fitting for LT/11 KV RCC pole as per the drawing No. EE/X/TRN/DR6 2/4 as per annexure confirming to IS- 2633/72 or the latest version thereof

9

91

819

... More
Erection of LT brown glazed shackle Insulator of size 100 mm x 115 mm conforming to fig No. 4 and type 2 fo IS: 1445/77 as amended upto date. Minimum failing load shall be 16 KN with GI hardware suitable for LT shackle insulator of size 100 x 115 mm conforming to type 2 fig 4 of IS: 1445/77 as amended upto date as per the drawing No.EE/X/TRN/DRG1/2.

30

104

3120

... More
Erection Metal parts for L.T. Shackle insulators or the Strap type fittings shall consists of a pair of H.D.G.I. straps, 2nos. H.D.G.I. bolts with hexagonal head & nuts, 2 nos. H.D.G.I. spring washers, & helically formed conductor dead-end fittings made of aluminium alloy or aluminium-clad steel conforming to the relevant IS specifications as per the drawing No.EE/X/TRN/DRG1/2.

30

104

3120

... More
Erection L.T. brown glazed porcelain pin insulators of size 100mmx70mm conforming to type 1 fig 1 of IS: 1445/1977 with amendment 2 of Feb 1981 (second revision) as amended upto date as per the drawing No.CEE/E-814 with Minimum failing load shall be 3.5 KN.

10

99

990

... More
Erection G.I. Pin for L.T.Pin Insulators conforming to IS 7935/1975 as amended upto date suitable for LT porcelain pin insulator type 1 conforming to fig 1 of IS: 1445/77 with amendment no 2 feb 1981, of size 100 x 70 mm. GI pin shall comprise of GI nut and spring washer and conform to fig No 2 of IS: 7935/1975. Minimum failing load of pin shall be 3.5 KN L.T. Pin Insulators

10

74

740

... More
Stringing of AAC 'ANT' Conductor, hard drawn stranded aluminium conductor & conforming to IS:398(Pt-I/76) with ammendment no. 1,2 & 3 & of size 7/3.10mm aluminium, (nominal aluminium area 50mm)

0.55

10300

5665

... More
Stringing of AAC 'GNAT' Conductor, hard drawn stranded aluminium conductor & conforming to IS:398(Pt-I/76) with ammendment no. 1,2 & 3 & of size 7/2.21mm aluminium, (nominal aluminium area 25mm2)

0.55

9100

5005

... More
Stringing of Hard drawn stranded aluminium conductor galvanized steel reinforced & conforming to IS:398(Pt-II/96) with amendment no. 1 & 3 & of size 6/2.59 mm aluminium, 1/2.59 mm steel wire "WEASEL"

0.45

11000

4950

... More
Erection PVC insulated single core cable 50 mm2 for D.P. earthing

50

56

2800

... More
Erection 11 KV rated voltange GOAB switches tilting type, outdoor, manually operated, triple pole, single break, conforming toIS-9921 (Part-I to IV) [ 1981 - 85] as amended up to date and detailed specification eclosed herewith. Each set shall comprise of six pedestal and three tilting post insulators. Insulator should be factory cemented by the manufacturer of the insulators and have minimum 320 mm creepage distance and AB switchs contacts shall be of copper/ copper alloy. The AB switch shall be of following current rating: 200 A

1

3971

3971

... More
Erection of 9 KV, 5 KA nominal discharge current metal oxide gapless distribution class Lightning arrestor conforming to IEC-600994-4 and IS: 3070 part 3 1993 as amended upto date suitable for 11 KV 50 HZ effectively earthed neutral system with necessary mounting arragements and connector suitable to connect ASCR conductor upto overall diameter 12.30 mm

3

174

522

... More
Erection of 11 KV , 200 A Horn gap fuse unit (Set of three) shall be as per drg No. CEE/E-786 as per annexure confirming toI.S. 2062,IS: 1367,IS: 4218,IS: 1363,IS-209 1979 or the latest version thereof

1

3368

3368

... More
Erection of MS Distribution box as per drg No. CEE/E-689 Revision No. 2 along with MCCB 400 A, Bus bar made out of Aluminium strips 40 x 10 mm, Other accessories & 200 Amps, Porcelain KitKat Fuse Carrier & Base with extended terminals shall be as per drawing No.CEE/E/543-Rev 4 (Set of 3) for 4 feeder arrangement with 1 no of moulded case circuit breaker (MCCB) of 400A, 415V, AC 50 Hz for 100 KVA Distribution Transformer centre

1

8795

8795

... More
Erection Enamelled Danger board 400V of size 250mm x 200 mm as per the drawing No. CEE/E-490.

5

57

285

... More
Erection Anticlimbing deviceas per the drawing No. CEE/E-478.

5

175

875

... More
Erection HDGI DP Structural material shall include :-a) GI channel ISMC 75x40x7.3mm 2.75 mtrs long 2 pieces for incoming line & installation of disc insulators b) GI channel ISMC75x40x7.3mm 2.75mtrs long 2 pieces for GOAB switch c) GI channel ISMC 75x40x7.3mm 2.75 mtrs long 2 pieces for HG fuses d) GI channel ISMC 75x40x7.3mm 2.75 mtrs long 2 pieces for installation of lightening arrestor e) GI channel ISMC 100x50x7.3mm 2.75 mtrs long 2 pieces for installation of Trasformer f) GI channel ISMC 75x40x7.3mm 2.75 mtrs long 2 pieces for side support of trasformer g) GI channel ISMC 75x40x7.3mm 2.75 mtrs long 4 pieces for installation of any other items h) GI channel ISMC 100x40x7.3mm 0.52 mtrs long 2 pieces for installation of Transformer base channel

380

47

17860

... More
Earthing complete comprises of H.D.G.I. Pipe of class B length 2.5 mts , 40mm nominal bore(outside diameter 48.8mm maximum and 47.9mm minimum ,thickness4.0mm and mass of tube plain end 4.37kg/m) conforming to IS1239 Part 1 1990 asamended upto date and hot dip zinc coating shall conform to IS 4736 as ACSR'Weasel' Conductor( quantity as required) , pit filled with homogeneous layer of20 kgs of charcoal, sand and salt as per the drawing No. CEE/E-829

8

2444

19552

... More
Erection of FRP Fencing Complete with Gate as per specifcation for Distribution Transformer (Size 6MX3MX2M) with Concreting for FRP Fencing supports with plinth (03x0.3x0.5) Cu.m. x 18 nos. Each ratio 1:3:6

1

33667

33667

... More
Erection XLPE Single Core unarmoured 300 sq mm,cross linked polyethelene insulated, PVC shealthed 1 core 300 sqmm cable 1.1.KV gradesuitable for 3 phase earthed system and conforming to IS: 7098 (Part-I)/1988 as amended upto date.

40

218

8720

... More
Erection of Three and half core armoured XLPE cable of size 120 Sq.mm cross linked polyethelene insulated, PVC shealthed 3.5 core 120 sqmm cable with galvanized steel strip armoured aluminium cable of 1100 volts grade suitable for 3 phase earthed system and conforming to IS: 7098 (Part-I)/1988 as amended upto date.

50

176

8800

... More
Erection of Aluminium crimping Lugs shall conform to IS: 8309-1976 as amended upto date. Lugs shall be made of aluminium of grade IE of IS: 5082/1969 suitable for aluminium cable of 300 sq.mm

8

101

808

... More
Erection of Aluminium crimping Lugs shall conform to IS: 8309-1976 as amended upto date. Lugs shall be made of aluminium of grade IE of IS: 5082/1969 suitable for aluminium cable of 120 sq.mm

12

88

1056

... More
Erection of 100 KVA 11kv/.4kv Distribution Transformers level II losses, Alluminium Winding, with Bimetallic Terminal Connectors, Energy Efficiency Level-II as per IS: 1180 (Part-I): 2014

1

11017

11017

... More
Erection of DTC Metering Unit

1

1072

1072

... More
Removing and Restringing of AAC 'ANT' Conductor,

0.1

15450

1545

... More
Removing and Restringing of AAC 'GNAT' Conductor,

0.1

13650

1365

... More
Removing of RCC poles 9.00 mtr

1

2950

2950

... More
Removing HDGI 2 pin 'X' arm of 75 x 40 Channel

2

116

232

... More
Removing HDGI 4 pin 'X' arm of 75 x 40 Channel

2

130

261

... More
Removing L.T. Shackle insulators

12

52

624

... More
Removing Metal parts for L.T. Shackle insulators

12

52

624

... More
Removing L.T. Pin Insulators

5

49

247.5

... More
Removing G.I. Pin for L.T.Pin Insulators

5

37

185

... More
Feeder issolation and replacement of damaged HT pole on the existing sancoale cortalim feeder in the vicinity of new DTC

-

-

-

... More
Erection of RCC pole 11 mtr as per the drawing No.CEE/E-698 REV-3 as per annexure confirming to IS 785-1998 as amended upto date. The component used for pole shall conform to following IS amended up to date. 1) Ordinary Port land cement 53 grade IS 12269 2) Aggregate IS 383-1970 3) Torsteel IS 1786-7985 4) MS bar IS 432 p 1 & 2-1982

4

9800

39200

... More
Erection of HDGI 2 pin 'X' arm of 75 x 40 Channel as per the drawing No.CEE/E/704 as per annexure confirming to IS- 2633/72 or the latest version thereof

4

232

928

... More
Erection of HDGI 4 pin 'X' arm of 75 x 40 Channel as per the drawing No.CEE/E/705 as per annexure confirming to IS- 2633/72 or the latest version thereof.

4

261

1044

... More
Erection of HDGI Cut point of 75 x 40 x 7.3 mm Channel 1.3 Mtr long as per the drawing No EE/IV/11 KV/X-Arms as per annexure confirming to IS - 2633/72or the latest version thereof

2

492

984

... More
Erection of HDGI 11 KV V-shape 'X' arm of 75 x 40 x 7.3 mm channel as per the drawing No.CEE/E-408 as per annexure confirming to IS-2633/72 or the latest version thereof

4

338

1352

... More
Erection of HDGI Guard of 75 x 40 x 7.3 mm Channel of 1.5 Mts long as per annexure confirming to IS -2633/72or the latest version thereof

5

546

2730

... More
Erection of HDGI X arm clamps for RCC Pole 11.00 mtr L.A as per the drawing No.CEE/E-711 as per annexure confirming to IS- 2633/72 or the latest version thereof

12

65

780

... More
Erection of HDGI stay clamps for RCC Pole 11.00 Mts L.A.as per the drawing No.CEE/E-711 as per annexure confirming to IS- 2633/72 or the latest version thereof

6

98

588

... More
Erection of HDG.I. stay wire 7/10 SWG conforming to IS-2141/1979 grade- I, IS:4826-1979 & IS:6594-1974 or latest version thereof with tensile grade 4 & having minimum tensile strenght of 700N/mm2 conforming to IS:2141 or the latest version thereof

9.5

62

589

... More
Erection of H.D.G.I. stay rod of 1200mm long and 16mm dia with an eye band of internal dia 40mm at one end and threaded up to length of 200mm at the other end galvanised. H.D.G.I.stay plate of 450x450x8mm size with a hole drilled at the centre to suit 16mm dia GI rod galvanised.as per the drawing No. CEE/E-465

2

1779

3558

... More
Erection G.I. Turn Buckle with eye bolt 11 KV as per the drawing No. CEE/E-466

2

267

534

... More
Erection of Break insulators 8 KV (44KN) as per the drawing No. CEE/E-425 as per annexure confirming to the IS:5300-1969 or the latest version thereof

2

97

194

... More
Erection of G.I. Nuts & Bolts as per annexure confirming to the IS- 2633/72 or the latest version thereof

6

30

180

... More
Erection 11 KV brown glazed ball and socket type disc insulators as per the drawing No. CEE/E-128 conforming to IS:2486 Pt No.1 to 4 and type 46 of IS-3188/80 as ammended upto date for a minimum failing load of 45KN with minimum creepage distance of 320 mm with16mm ball and socket alternative `B'

12

154

1848

... More
Erection of Metal parts for 11 KV disc 45 KN, 3 bolted type as per IS-2486 part - II& III /1974 as ammended upto date& 3 `U' bolted type tension/ suspension clamp.

12

178

2136

... More
Erection of 11 KV Brown glazed pin insulator having minimum failing load of 10KN in tranverse direction & 45KN applied axially. The minimum creepage distance shall be of 320 mm conforming to type B of IS:731/71 & IS:3188 as ammended from time to time. The dimensions of the 11KV pin insulator will be as per drawing no. EE VI 01

9

76

684

... More
Erection G.I. Pin for 11 KV Pin Insulators shall be H.D.G.I. small steel head type S 165 P as per IS:2486(Part-I & II) having stalk lenght of 165 mm and shank lenght of 150mm with a minimum failing load of 10KN. The dimensions of the 11KV pin insulator will be as per drawing no. EE VI 01

9

76

684

... More
Erection of HDGI top fitting for LT/11 KV RCC pole as per the drawing No. EE/X/TRN/DR6 2/4 as per annexure confirming to IS- 2633/72 or the latest version thereof

9

91

819

... More
Erection of LT brown glazed shackle Insulator of size 100 mm x 115 mm conforming to fig No. 4 and type 2 fo IS: 1445/77 as amended upto date. Minimum failing load shall be 16 KN with GI hardware suitable for LT shackle insulator of size 100 x 115 mm conforming to type 2 fig 4 of IS: 1445/77 as amended upto date as per the drawing No.EE/X/TRN/DRG1/2.

18

104

1872

... More
Erection of Metal parts for L.T. Shackle insulators or the Strap type fittings shall consists of a pair of H.D.G.I. straps, 2nos. H.D.G.I. bolts with hexagonal head & nuts, 2 nos. H.D.G.I. spring washers, & helically formed conductor dead-end fittings made of aluminium alloy or aluminium-clad steel conforming to the relevant IS specifications as per the drawing No.EE/X/TRN/DRG1/2.

18

104

1872

... More
Erection of L.T. brown glazed porcelain pin insulators of size 100mmx70mm conforming to type 1 fig 1 of IS: 1445/1977 with amendment 2 of Feb 1981 (second revision) as amended upto date as per the drawing No.CEE/E-814 with Minimum failing load shall be 3.5 KN.

10

99

990

... More
Erection of G.I. Pin for L.T.Pin Insulators conforming to IS 7935/1975 as amended upto date suitable for LT porcelain pin insulator type 1 conforming to fig 1 of IS: 1445/77 with amendment no 2 feb 1981, of size 100 x 70 mm. GI pin shall comprise of GI nut and spring washer and conform to fig No 2 of IS: 7935/1975. Minimum failing load of pin shall be 3.5 KN L.T. Pin Insulators

10

74

740

... More
Stringing of AAC 'ANT' Conductor, hard drawn stranded aluminium conductor & conforming to IS:398(Pt-I/76) with ammendment no. 1,2 & 3 & of size 7/3.10mm aluminium, (nominal aluminium area 50mm)

0.4

10300

4120

... More
Stringing of AAC 'GNAT' Conductor, hard drawn stranded aluminium conductor & conforming to IS:398(Pt-I/76) with ammendment no. 1,2 & 3 & of size 7/2.21mm aluminium, (nominal aluminium area 25mm2)

0.4

9100

3640

... More
Stringing of Hard drawn stranded aluminium conductor galvanized steel reinforced & conforming to IS:398(Pt-II/96) with amendment no. 1 & 3 & of size 6/2.59 mm aluminium, 1/2.59 mm steel wire "WEASEL"

0.4

11000

4400

... More
Erection 11 KV rated voltange GOAB switches tilting type, outdoor, manually operated, triple pole, single break, conforming toIS-9921 (Part-I to IV) [ 1981 - 85] as amended up to date and detailed specification eclosed herewith. Each set shall comprise of six pedestal and three tilting post insulators. Insulator should be factory cemented by the manufacturer of the insulators and have minimum 320 mm creepage distance and AB switchs contacts shall be of copper/ copper alloy. The AB switch shall be of following current rating: 200 A

2

3971

7942

... More
Erection of 9 KV, 5 KA nominal discharge current metal oxide gapless distribution class Lightning arrestor conforming to IEC-600994-4 and IS: 3070 part 3 1993 as amended upto date suitable for 11 KV 50 HZ effectively earthed neutral system with necessary mounting arragements and connector suitable to connect ASCR conductor upto overall diameter 12.30 mm

3

174

522

... More
Erection of Enamelled Danger board 400V of size 250mm x 200 mm as per the drawing No. CEE/E-490.

4

57

228

... More
Anticlimbing deviceas per the drawing No. CEE/E-478. for erection

4

148

592

... More
Removing of AAC 'ANT' Conductor,

0.36

5150

1854

... More
Removing of AAC 'GNAT' Conductor,

0.36

4550

1638

... More
Removing of RCC poles 9.00 mtr

4

2950

11800

... More
Removing HDGI 2 pin 'X' arm of 75 x 40 Channel

4

116

464

... More
Removing HDGI 4 pin 'X' arm of 75 x 40 Channel

4

130

522

... More
Removing L.T. Shackle insulators

18

52

936

... More
Removing Metal parts for L.T. Shackle insulators

18

52

936

... More
Removing L.T. Pin Insulators

10

49

495

... More
Removing G.I. Pin for L.T.Pin Insulators

10

37

370



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements

Past Bidders
This list is curated from the bidders of the similar tenders in the past

Unlock the Tender details for free
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.