Electricity Department Tender

View complete overview of Goa Electricity Department Tender

Electricity Department Tender

Works
Civil And Construction
Eprocure
Opening Date1 Aug 2023
Closing Date11 Aug 2023
Tender Amount₹ 7,99,143 
Notes
Download

Costs

  • EMD

    ₹ 15,983
  • Document Cost

    ₹ 1,000
  • Tender Fee

    ₹ 1,598

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
Supply and ErectionHDGI Guard of 75 x 40 x 7.3 mm Channel of 1.5 Mts long as per annexure confirming to IS -2633/72or the latest version thereof

12

26352

2196

... More
Supply and Erection HDGI X arm clamps for RCC Pole 11.00 mtr L.A as per the drawing No.CEE/E-711 as per annexure confirming to IS- 2633/72 or the latest version thereof

53

21942

414

... More
HDGI st. light clamps for 40 mm pipe (top/bottom) for 11 Mtrs RCC Pole

20

10040

502

... More
Supply and Erection of HDG.I. stay wire 7/10 SWG conforming to IS-2141/1979 grade- I, IS:4826-1979 & IS:6594-1974 or latest version thereof with tensile grade 4 & having minimum tensile strenght of 700N/mm2 conforming to IS:2141 or the latest version thereof

31.99

4510

141

... More
Supply and Erection of Break insulators 8 KV (44KN) as per the drawing No. CEE/E-425 as per annexure confirming to the IS:5300-1969 or the latest version thereof

7

1232

176

... More
G.I. Nuts & Bolts as per annexure confirming to the IS- 2633/72 or the latest version thereof

40.77

9296

228

... More
Supply and Erection Metal parts for L.T. Shackle insulators or the Strap type fittings shall consists of a pair of H.D.G.I. straps, 2nos. H.D.G.I. bolts with hexagonal head & nuts, 2 nos. H.D.G.I. spring washers, & helically formed conductor dead-end fittings made of aluminium alloy or aluminium-clad steel conforming to the relevant IS specifications as per the drawing No.EE/X/TRN/DRG1/2.

72

14760

205

... More
Supply and Erection G.I. Pin for L.T.Pin Insulators conforming to IS 7935/1975 as amended upto date suitable for LT porcelain pin insulator type 1 conforming to fig 1 of IS: 1445/77 with amendment no 2 feb 1981, of size 100 x 70 mm. GI pin shall comprise of GI nut and spring washer and conform to fig No 2 of IS: 7935/1975. Minimum failing load of pin shall be 3.5 KN L.T. Pin Insulators

35

4445

127

... More
Supply and Stringing of AAC 'ANT' Conductor, hard drawn stranded aluminium conductor & conforming to IS:398(Pt-I/76) with ammendment no. 1,2 & 3 & of size 7/3.10mm aluminium, (nominal aluminium area 50mm)

0.14

6732

48086

... More
Supply and Stringing of AAC 'GNAT' Conductor, hard drawn stranded aluminium conductor & conforming to IS:398(Pt-I/76) with ammendment no. 1,2 & 3 & of size 7/2.21mm aluminium, (nominal aluminium area 25mm2)

0.15

3667

25293

... More
Supply and Stringing of Hard drawn stranded aluminium conductor galvanized steel reinforced & conforming to IS:398(Pt-II/96) with amendment no. 1 & 3 & of size 6/2.59 mm aluminium, 1/2.59 mm steel wire "WEASEL"

2.19

73165

33409

... More
Supply and Erection PVC insulated single core cable 50 mm2 for D.P. earthing

50

4150

83

... More
Supply and Erection Enamelled Danger board 400V of size 250mm x 200 mm as per the drawing No. CEE/E-490.

11

2728

248

... More
Supply and Erection Anticlimbing deviceas per the drawing No. CEE/E-478.

11

10582

962

... More
Supply and Erection HDGI DP Structural material shall include :-a) GI channel ISMC 75x40x7.3mm 2.75 mtrs long 2 pieces for incoming line & installation of disc insulators b) GI channel ISMC75x40x7.3mm 2.75mtrs long 2 pieces for GOAB switch c) GI channel ISMC 75x40x7.3mm 2.75 mtrs long 2 pieces for HG fuses d) GI channel ISMC 75x40x7.3mm 2.75 mtrs long 2 pieces for installation of lightening arrestor e) GI channel ISMC 100x50x7.3mm 2.75 mtrs long 2 pieces for installation of Trasformer f) GI channel ISMC 75x40x7.3mm 2.75 mtrs long 2 pieces for side support of trasformer g) GI channel ISMC 75x40x7.3mm 2.75 mtrs long 4 pieces for installation of any other items h) GI channel ISMC 100x40x7.3mm 0.52 mtrs long 2 pieces for installation of Transformer base channel

260

43940

169

... More
Earthing complete comprises of H.D.G.I. Pipe of class B length 2.5 mts , 40mm nominal bore(outside diameter 48.8mm maximum and 47.9mm minimum ,thickness4.0mm and mass of tube plain end 4.37kg/m) conforming to IS1239 Part 1 1990 asamended upto date and hot dip zinc coating shall conform to IS 4736 as ACSR'Weasel' Conductor( quantity as required) , pit filled with homogeneous layer of20 kgs of charcoal, sand and salt as per the drawing No. CEE/E-829

6

16380

2730

... More
FRP Fencing Complete with Gate as per specifcation for Distribution Transformer (Size 4MX3MX2M) with Concreting for FRP Fencing supports with plinth (03x0.3x0.5) Cu.m. x 12 nos. Each ratio 1:3:6

1

76667

76667

... More
Supply and Erection XLPE Single Core unarmoured 300 sq mm,cross linked polyethelene insulated, PVC shealthed 1 core 300 sqmm cable 1.1.KV gradesuitable for 3 phase earthed system and conforming to IS: 7098 (Part-I)/1988 as amended upto date.

40

19080

477

... More
Supply and Erection of Three and half core armoured XLPE cable of size 185 Sq.mm cross linked polyethelene insulated, PVC shealthed 3.5 core 185 sqmm cable with galvanized steel strip armoured aluminium cable of 1100 volts grade suitable for 3 phase earthed system and conforming to IS: 7098 (Part-I)/1988 as amended upto date.

36

48024

1334

... More
Supply and Erection of DTC Metering Unit

1

25688

25688

... More
COST OF ERECTION

-

-

-

... More
Supply and Erection of RCC pole 11 mtr as per the drawing No.CEE/E-698 REV-3 as per annexure confirming to IS 785-1998 as amended upto date. The component used for pole shall conform to following IS amended up to date. 1) Ordinary Port land cement 53 grade IS 12269 2) Aggregate IS 383-1970 3) Torsteel IS 1786-7985 4) MS bar IS 432 p 1 & 2-1982

11

94600

8600

... More
Supply and Erection HDGI 2 pin 'X' arm of 75 x 40 Channel as per the drawing No.CEE/E/704 as per annexure confirming to IS- 2633/72 or the latest version thereof

14

3248

232

... More
Supply and Erection HDGI 4 pin 'X' arm of 75 x 40 Channel as per the drawing No.CEE/E/705 as per annexure confirming to IS- 2633/72 or the latest version thereof.

14

3654

261

... More
Supply and Erection HDGI Cut point of 75 x 40 x 7.3 mm Channel 1.3 Mtr long as per the drawing No EE/IV/11 KV/X-Arms as per annexure confirming to IS - 2633/72or the latest version thereof

5

2460

492

... More
Supply and Erection HDGI 11 KV V-shape 'X' arm of 75 x 40 x 7.3 mm channel as per the drawing No.CEE/E-408 as per annexure confirming to IS-2633/72 or the latest version thereof

8

2704

338

... More
Supply and ErectionHDGI Guard of 75 x 40 x 7.3 mm Channel of 1.5 Mts long as per annexure confirming to IS -2633/72or the latest version thereof

12

6552

546

... More
Supply and Erection HDGI X arm clamps for RCC Pole 11.00 mtr L.A as per the drawing No.CEE/E-711 as per annexure confirming to IS- 2633/72 or the latest version thereof

53

3445

65

... More
HDGI st. light clamps for 40 mm pipe (top/bottom) for 11 Mtrs RCC Pole

20

940

47

... More
Supply and Erection HDGI stay clamps for RCC Pole 11.00 Mts L.A.as per the drawing No.CEE/E-711 as per annexure confirming to IS- 2633/72 or the latest version thereof

7

686

98

... More
Supply and Erection of HDG.I. stay wire 7/10 SWG conforming to IS-2141/1979 grade- I, IS:4826-1979 & IS:6594-1974 or latest version thereof with tensile grade 4 & having minimum tensile strenght of 700N/mm2 conforming to IS:2141 or the latest version thereof

31.99

1983

62

... More
Supply and Erection of H.D.G.I. stay rod of 1200mm long and 16mm dia with an eye band of internal dia 40mm at one end and threaded up to length of 200mm at the other end galvanised. H.D.G.I.stay plate of 450x450x8mm size with a hole drilled at the centre to suit 16mm dia GI rod galvanised.as per the drawing No. CEE/E-465

7

12453

1779

... More
Supply and Erection G.I. Turn Buckle with eye bolt 11 KV as per the drawing No. CEE/E-466

7

1869

267

... More
Supply and Erection of Break insulators 8 KV (44KN) as per the drawing No. CEE/E-425 as per annexure confirming to the IS:5300-1969 or the latest version thereof

7

679

97

... More
G.I. Nuts & Bolts as per annexure confirming to the IS- 2633/72 or the latest version thereof

40.77

1223

30

... More
Supply and Erection 11 KV brown glazed ball and socket type disc insulators as per the drawing No. CEE/E-128 conforming to IS:2486 Pt No.1 to 4 and type 46 of IS-3188/80 as ammended upto date for a minimum failing load of 45KN with minimum creepage distance of 320 mm with16mm ball and socket alternative `B'

24

3696

154

... More
Supply and Erection of Metal parts for 11 KV disc 45 KN, 3 bolted type as per IS-2486 part - II& III /1974 as ammended upto date& 3 `U' bolted type tension/ suspension clamp.

24

4272

178

... More
Supply and Erection of 11 KV Brown glazed pin insulator having minimum failing load of 10KN in tranverse direction & 45KN applied axially. The minimum creepage distance shall be of 320 mm conforming to type B of IS:731/71 & IS:3188 as ammended from time to time. The dimensions of the 11KV pin insulator will be as per drawing no. EE VI 01

24

1824

76

... More
Supply and Erection G.I. Pin for 11 KV Pin Insulators shall be H.D.G.I. small steel head type S 165 P as per IS:2486(Part-I & II) having stalk lenght of 165 mm and shank lenght of 150mm with a minimum failing load of 10KN. The dimensions of the 11KV pin insulator will be as per drawing no. EE VI 01

24

1824

76

... More
Supply and Erection of HDGI top fitting for LT/11 KV RCC pole as per the drawing No. EE/X/TRN/DR6 2/4 as per annexure confirming to IS- 2633/72 or the latest version thereof

8

728

91

... More
Supply and Erection of LT brown glazed shackle Insulator of size 100 mm x 115 mm conforming to fig No. 4 and type 2 fo IS: 1445/77 as amended upto date. Minimum failing load shall be 16 KN with GI hardware suitable for LT shackle insulator of size 100 x 115 mm conforming to type 2 fig 4 of IS: 1445/77 as amended upto date as per the drawing No.EE/X/TRN/DRG1/2.

72

7488

104

... More
Supply and Erection Metal parts for L.T. Shackle insulators or the Strap type fittings shall consists of a pair of H.D.G.I. straps, 2nos. H.D.G.I. bolts with hexagonal head & nuts, 2 nos. H.D.G.I. spring washers, & helically formed conductor dead-end fittings made of aluminium alloy or aluminium-clad steel conforming to the relevant IS specifications as per the drawing No.EE/X/TRN/DRG1/2.

72

7488

104

... More
Supply and Erection L.T. brown glazed porcelain pin insulators of size 100mmx70mm conforming to type 1 fig 1 of IS: 1445/1977 with amendment 2 of Feb 1981 (second revision) as amended upto date as per the drawing No.CEE/E-814 with Minimum failing load shall be 3.5 KN.

35

3465

99

... More
Supply and Erection G.I. Pin for L.T.Pin Insulators conforming to IS 7935/1975 as amended upto date suitable for LT porcelain pin insulator type 1 conforming to fig 1 of IS: 1445/77 with amendment no 2 feb 1981, of size 100 x 70 mm. GI pin shall comprise of GI nut and spring washer and conform to fig No 2 of IS: 7935/1975. Minimum failing load of pin shall be 3.5 KN L.T. Pin Insulators

35

2590

74

... More
Supply and Stringing of AAC 'ANT' Conductor, hard drawn stranded aluminium conductor & conforming to IS:398(Pt-I/76) with ammendment no. 1,2 & 3 & of size 7/3.10mm aluminium, (nominal aluminium area 50mm)

0.14

928

6634

... More
Supply and Stringing of AAC 'GNAT' Conductor, hard drawn stranded aluminium conductor & conforming to IS:398(Pt-I/76) with ammendment no. 1,2 & 3 & of size 7/2.21mm aluminium, (nominal aluminium area 25mm2)

0.15

896

6183

... More
Supply and Stringing of Hard drawn stranded aluminium conductor galvanized steel reinforced & conforming to IS:398(Pt-II/96) with amendment no. 1 & 3 & of size 6/2.59 mm aluminium, 1/2.59 mm steel wire "WEASEL"

2.19

15570

7110

... More
Supply and Erection PVC insulated single core cable 50 mm2 for D.P. earthing

50

2800

56

... More
Supply and Erection 11 KV rated voltange GOAB switches tilting type, outdoor, manually operated, triple pole, single break, conforming toIS-9921 (Part-I to IV) [ 1981 - 85] as amended up to date and detailed specification eclosed herewith. Each set shall comprise of six pedestal and three tilting post insulators. Insulator should be factory cemented by the manufacturer of the insulators and have minimum 320 mm creepage distance and AB switchs contacts shall be of copper/ copper alloy. The AB switch shall be of following current rating: 200 A

1

3971

3971

... More
Supply and Erection of 9 KV, 5 KA nominal discharge current metal oxide gapless distribution class Lightning arrestor conforming to IEC-600994-4 and IS: 3070 part 3 1993 as amended upto date suitable for 11 KV 50 HZ effectively earthed neutral system with necessary mounting arragements and connector suitable to connect ASCR conductor upto overall diameter 12.30 mm

3

522

174

... More
11 KV , 200 A Horn gap fuse unit (Set of three) shall be as per drg No. CEE/E-786 as per annexure confirming toI.S. 2062,IS: 1367,IS: 4218,IS: 1363,IS-209 1979 or the latest version thereof

1

3368

3368

... More
Supply and Erection of MS Distribution box as per drg No. CEE/E-689 Revision No. 2 along with MCCB 400 A, Bus bar made out of Aluminium strips 40 x 10 mm, Other accessories & 200 Amps, Porcelain KitKat Fuse Carrier & Base with extended terminals shall be as per drawing No.CEE/E/543-Rev 4 (Set of 3) for 4 feeder arrangement with 1 no of moulded case circuit breaker (MCCB) of 400A, 415V, AC 50 Hz for 100 KVA Distribution Transformer centre

1

8795

8795

... More
Supply and Erection Enamelled Danger board 400V of size 250mm x 200 mm as per the drawing No. CEE/E-490.

11

627

57

... More
Supply and Erection Anticlimbing deviceas per the drawing No. CEE/E-478.

11

1925

175

... More
Supply and Erection HDGI DP Structural material shall include :-a) GI channel ISMC 75x40x7.3mm 2.75 mtrs long 2 pieces for incoming line & installation of disc insulators b) GI channel ISMC75x40x7.3mm 2.75mtrs long 2 pieces for GOAB switch c) GI channel ISMC 75x40x7.3mm 2.75 mtrs long 2 pieces for HG fuses d) GI channel ISMC 75x40x7.3mm 2.75 mtrs long 2 pieces for installation of lightening arrestor e) GI channel ISMC 100x50x7.3mm 2.75 mtrs long 2 pieces for installation of Trasformer f) GI channel ISMC 75x40x7.3mm 2.75 mtrs long 2 pieces for side support of trasformer g) GI channel ISMC 75x40x7.3mm 2.75 mtrs long 4 pieces for installation of any other items h) GI channel ISMC 100x40x7.3mm 0.52 mtrs long 2 pieces for installation of Transformer base channel

260

12220

47

... More
Earthing complete comprises of H.D.G.I. Pipe of class B length 2.5 mts , 40mm nominal bore(outside diameter 48.8mm maximum and 47.9mm minimum ,thickness4.0mm and mass of tube plain end 4.37kg/m) conforming to IS1239 Part 1 1990 asamended upto date and hot dip zinc coating shall conform to IS 4736 as ACSR'Weasel' Conductor( quantity as required) , pit filled with homogeneous layer of20 kgs of charcoal, sand and salt as per the drawing No. CEE/E-829

6

14664

2444

... More
FRP Fencing Complete with Gate as per specifcation for Distribution Transformer (Size 4MX3MX2M) with Concreting for FRP Fencing supports with plinth (03x0.3x0.5) Cu.m. x 12 nos. Each ratio 1:3:6

1

35000

35000

... More
Supply and Erection XLPE Single Core unarmoured 300 sq mm,cross linked polyethelene insulated, PVC shealthed 1 core 300 sqmm cable 1.1.KV gradesuitable for 3 phase earthed system and conforming to IS: 7098 (Part-I)/1988 as amended upto date.

40

8720

218

... More
Supply and Erection of Three and half core armoured XLPE cable of size 185 Sq.mm cross linked polyethelene insulated, PVC shealthed 3.5 core 185 sqmm cable with galvanized steel strip armoured aluminium cable of 1100 volts grade suitable for 3 phase earthed system and conforming to IS: 7098 (Part-I)/1988 as amended upto date.

36

8208

228

... More
Supply and Erection of Aluminium crimping Lugs shall conform to IS: 8309-1976 as amended upto date. Lugs shall be made of aluminium of grade IE of IS: 5082/1969 suitable for aluminium cable of 300 sq.mm

8

808

101

... More
Supply and Erection of Aluminium crimping Lugs shall conform to IS: 8309-1976 as amended upto date. Lugs shall be made of aluminium of grade IE of IS: 5082/1969 suitable for aluminium cable of 185 sq.mm

12

1140

95

... More
100 KVA 11kv/.4kv Distribution Transformers level II losses, Alluminium Winding, with Bimetallic Terminal Connectors, Energy Efficiency Level-II as per IS: 1180 (Part-I): 2014

1

11017

11017

... More
Supply and Erection of DTC Metering Unit

1

1072

1072

... More
Removing and Restringing of AAC 'ANT' Conductor,

1.8

17911

9951

... More
Removing and Restringing of AAC 'GNAT' Conductor,

1.8

16694

9274.5

... More
Removing of RCC poles 9.00 mtr

9

19836

2204

... More
Removing HDGI 2 pin 'X' arm of 75 x 40 Channel

11

1276

116

... More
Removing HDGI 4 pin 'X' arm of 75 x 40 Channel

11

1435

130.5

... More
Removing L.T. Shackle insulators

20

1040

52

... More
Removing Metal parts for L.T. Shackle insulators

20

1040

52

... More
Removing L.T. Pin Insulators

40

1980

49.5

... More
Removing G.I. Pin for L.T.Pin Insulators

40

1480

37



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.