Electricity Department Tender

View complete overview of Goa Electricity Department Tender

Electricity Department Tender

Works
Electrical Generators And Transformers
Electrical and Electronics
Eprocure
Opening Date2 Feb 2024
Closing Date12 Feb 2024
Tender Amount₹ 50,31,080 
Notes
Download

Costs

  • EMD

    ₹ 1,00,622
  • Document Cost

    ₹ 1,000
  • Tender Fee

    ₹ 6,000

Summary

Tender For The Work Of Erection Of New 200kva Transformer Center At Ambeshiwada, Amona In The Jurisdiction Of Section Office Kudne Under Sub Division-ii(r ), Sankhali, Division V, Bicholim.

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
Supply of 11 KV Termination kit Outdoor 3 core 120 sqmm XLPE

4

43724

10931

... More
Supply of Cable Route marker (400x900x100mm)

10

5280

528

... More
Supply of Warning tape.

0.85

12750

15000

... More
Earthwork in excavation by mechanical means (hydraulic excavator)/manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sq.m on plan) including disposal of excavated earth lead upto 50 m and lift upto 1.5m disposed earth to be leveled and neatly dressed including providing barricading, danger lighting guarding as directed in : a) All kinds of soil and b)All types of Ordinary rock including all types off laterite rock, blasting prohibited Refilling the pipeline/foundation trenches plinth sides, foundation etc. with available excavated earth in layers not exceeding 20 cm depth consolidating each layer ramming and watering lead upto 50 M and all lifts and disposal of surplus earth as directed by Engineer in Charge. ( Deduct for RCC slab) Sand : supplying and filling in plinth under floors, trenches including watering ramming consolidating, dressing, complete. (Deduct for 11kV cable & Deduct for brick) Bricks class design 75 kg/cm2 (1st class wire cut)

850

660450

777

... More
Supply of RCC Hume Pipe 150mm dia with required no. of collars, for road crossing.

30

9510

317

... More
Supply of GI Pipe 150mm, class B

40

67240

1681

... More
Supply of RCC protective covers of size 600mm long x 250mm width and 50mm thick capable of bearing load of 135Kg. And covered with earth/ sand upto depth of 0.15mts. Confirming to IS 1255-1967 at non-road crossing.

2834

359918

127

... More
Supply of RCC pole 9.0 mtr as per the drawing No.CEE/E-698, REV-1 as per annexure confirming to IS 785-1998 as amended upto date. The component used for pole shall conform to following IS amended up to date. 1) Ordinary Port land cement 53 grade IS 12269 2) Aggregate IS 383-1970 3) Torsteel IS 1786-7985 4) MS bar IS 432 p 1 & 2-1982

5

41930

8386

... More
Supply of H.D.G.I. stay rod of 1200mm long & 16mm dia with an eye band of internal dia 40mm at one end & threaded up to length of 200mm at the other end, H.D.G.I. stay plate 450x450x8mm size with a hole for at the centre to suit above stay rod, H.D.G.I. stay wire of size 7/5.15mm (7/8SWG) conforming to IS-2141/1979 grade- I, IS:4826-1979 & IS:6594-1974 or latest version thereof with tensile grade 4 & having minimum tensile strenght of 700N/mm2, H.D.G.I. turn buckle made out of 16mm dia H.D.G.I. rod & H.D.G.I. angle of size ISA 50x50x6mm, eye bolt made out of 20mmdia H.D.G.I. rod with 40mm dia inner dia eye at one end & threaded up to 300mm lenght from other side, along with H.D.G.I. hexagonal nuts suitable for above rod , break insulator of 16KV & minimum failing load of 44KN, & along with suitable H.D.G.I. stay clamps suitable for 9 mts RCC pole, H.D.G.I. nut bolts & of specifications as specified in drg nos. CEE/E-797, CEE/E-466, CEE/E-524, CEE/E-523 & CEE/E-711

5

21376

4275.34

... More
Supply of HDGI structure material for DPS. Each trasformer centre DP consist of HDGI structure material as follows: a) GI channel ISMC 75x40x7.3mm 2.75 mtrs long 2 pieces for incoming line & installation of disc insulators b) GI channel ISMC75x40x7.3mm 2.75mtrs long 2 pieces for GOAB switch c) GI channel ISMC 75x40x7.3mm 2.75 mtrs long 2 pieces for HG fuses d) GI channel ISMC 75x40x7.3mm 2.75 mtrs long 2 pieces for installation of lightening arrestor e) GI channel ISMC 100x50x7.3mm 2.75 mtrs long 2 pieces for installation of Trasformer f) GI channel ISMC 75x40x7.3mm 2.75 mtrs long 2 pieces for side support of trasformer g) GI channel ISMC 75x40x7.3mm 2.75 mtrs long 4 pieces for installation of any other items h) GI channel ISMC 100x40x7.3mm 0.52 mtrs long 2 pieces for installation of Transformer base channel

274

46306

169

... More
Supply of 11 KV , 200 A Horn gap fuse unit (Set of three) shall be as per enclosed drg No. CEE/E-786. Revision 3 and detailed specifications enclosed herewith.

1

10450

10450

... More
Supply of 11 KV rated voltange GOAB switches tilting type, outdoor, manually operated, triple pole, single break, conforming to IS: 9921-Part 1 to V as amended up to date and detailed specification eclosed herewith. Each set shall comprise of six pedestal and three tilting post insulators. Insulator should be factory cemented by the manufacturer of the insulators and have minimum 320 mm creepage distance and AB switchs contacts shall be of copper/ copper alloy. The AB switch shall be of following current rating: 200 A

1

23535

23535

... More
Supply of 9 KV, 5 KA nominal discharge current metal oxide gapless distribution class Lightning arrestor conforming to IEC-600994-4 and IS: 3070 part 3 1993 as amended upto date suitable for 11 KV 50 HZ effectively earthed neutral system with necessary mounting arragements and connector suitable to connect ASCR conductor upto overall diameter 12.30 mm

3

9099

3033

... More
Supply of Distribution Transformer 200 KVA 11/0.44 KVA Aluminium wound Star rated

1

377405

377405

... More
Supply of MS Distribution box as per drg No. CEE/E-689 Revision No. 3 along with MCCB 400 A, Bus bar made out of Aluminium strips 40 x 10 mm,aluminium 'J' type fuse links (Set of 3) for 4 feeder arrangement with 1 no of moulded case circuit breaker (MCCB) of 400A, 415V, AC 50 Hz for 200 KVA Distribution Transformer centre

1

63140

63140

... More
Supply of Distribution Transformer Metering unit with DLMS/COSEM protocol energy meter with modem

1

31688

31688

... More
Supply of ACSR 'Weasel' conductor confirming ISI specification IS: 398 (part-1/96) as amended upto date of following sizes 6/1/2.59 mm for guarding

0.3

10022

33409

... More
Supply of Single core XLPE Insulated PVC Sheathed cable 185sqmm 1.1kV grade

40

9800

245

... More
Supply of Single core XLPE Insulated PVC Sheathed cable 95sqmm 1.1kV grade

120

15360

128

... More
Supply of Three and half core armoured XLPE cable of size 95 Sq.mm cross linked polyethelene insulated, PVC shealthed 3.5 core 95 sqmm cable with galvanized steel strip armoured aluminium cable of 1100 volts grade suitable for 3 phase earthed system and conforming to IS: 7098 (Part-I)/1988 as amended upto date.

24

17616

734

... More
Supply of Enamelled danger boards 11000 Volts as per drg no. CEE/E-490

2

496

248

... More
Supply of HDGI earthing pipe 8ft long 40mm. Dia. Class B fabricated & perforated including alternate layers of 30cms thick of charcoal,salt & earth( charcoal & salt 10kgs each per pit inclusive of excavation,bacfilling& spreading the earth evenly)with brick masonary.

6

26568

4428

... More
Supply of Anti climbing device alongwith suitable two stay clamps & two pairs of H.D.G.I nuts bolts as per drg No. CEE/E-478

2

1924

962

... More
Supply of FRP Fencing complete with Gate as per specification for Distribution Transformer (3Mx3Mx2M) with concreting for FRP fencing supports with plinth (0.3x0.3x0.5) Cu.mx12 nos. Each ratio 1;3;6

1

71167

71167

... More
Supply of HDG L.T. 4 pin cross arm Channel type made of ISMC 75x40x7.3mm as per drg No.CEE/E-491

11

12199

1109

... More
Supply of HDGI L.T. 2 pin cross arm Channel type made of ISMC 75x40x7.3mm as per drg No.CEE/E-491

6

3414

569

... More
Supply of HDGI X arm clamp for Rcc pole 9mtr S.A

8

2128

266

... More
Supply of HDGI X arm clamp for Rcc pole 9mtr L.A

9

2394

266

... More
Supply of G.I. Nuts & Bolts 100 X 16 mm

10

2280

228

... More
Supply of LT brown glazed shackle Insulator of size 100 mm x 115 mm conforming to fig No. 4 and type 2 fo IS: 1445/77 as amended upto date. Minimum failing load shall be 16 KN with GI hardware suitable for LT shackle insulator of size 100 x 115 mm conforming to type 2 fig 4 of IS: 1445/77 as amended upto date. Hardware or fitting shall conform to fig 4 of IS: 7935-1975 as amended upto date comprise fo 2 GI strips, 2 GI bolts and 2 nuts with spring washers.

64

23808

372

... More
Supply of L.T. brown glazed porcelain pin insulators of size 100mmx70mm conforming to type 1 fig 1 of IS: 1445/1977 with amendment 2 of Feb 1981 (second revision) as amended upto date. Minimum failing load shall be 3.5 KN with Forged GI pin conforming to IS 7935/1975 as amended upto date suitable for LT porcelain pin insulator type 1 conforming to fig 1 of IS: 1445/77 with amendment no 2 feb 1981, of size 100 x 70 mm. GI pin shall comprise of GI nut and spring washer and conform to fig No 2 of IS: 7935/1975. Minimum failing load of pin shall be 3.5 KN

10

2630

263

... More
Supply of AAC conductor hard drawn stranded all aluminium conductor conforming IS 398(Part-1/96) as amended upto date of following sizes 7/3.10 mm ANT conductor for phases

0.73

35102

48086

... More
Supply of AAC conductor hard drawn stranded all aluminium conductor conforming IS 398(Part-1/96) as amended upto date of following sizes 7/2.21 mm GNAT conductor for double neutral & guadings.

0.39

9864

25293

... More
Cost of Erection

-

-

-

... More
Laying, Testing & commissioning of 11KV, 3 core 120 sq.mm A2XFY Aluminium Armoured XLPE Cable through conventional open trenching method in any type of soil including hard laterite.

1700

367200

216

... More
Erection, Testing & Commissioning of 11 KV Straight Through joint 3 core 120 sqmm XLPE

2

6900

3450

... More
Erection, Testing & Commissioning of of 11 KV Termination kit Outdoor 3 core 120 sqmm XLPE

4

10592

2648

... More
Erection of Cable Route marker (400x900x100mm)

10

2560

256

... More
Laying of RCC Hume Pipe 150mm dia with required no. of collars, for road crossing.

30

4530

151

... More
Laying of GI Pipe 150mm, class B

40

7280

182

... More
Laying of RCC protective covers of size 600mm long x 250mm width and 50mm thick capable of bearing load of 135Kg. And covered with earth/ sand upto depth of 0.15mts. Confirming to IS 1255-1967 at non-road crossing.

2834

238056

84

... More
Erection of RCC pole 9.0 mtr as per the drawing No.CEE/E-698, REV-1 as per annexure confirming to IS 785-1998 as amended upto date. The component used for pole shall conform to following IS amended up to date. 1) Ordinary Port land cement 53 grade IS 12269 2) Aggregate IS 383-1970 3) Torsteel IS 1786-7985 4) MS bar IS 432 p 1 & 2-1982

5

22040

4408

... More
Erection of H.D.G.I. stay rod of 1200mm long & 16mm dia with an eye band of internal dia 40mm at one end & threaded up to length of 200mm at the other end, H.D.G.I. stay plate 450x450x8mm size with a hole for at the centre to suit above stay rod, H.D.G.I. stay wire of size 7/5.15mm (7/8SWG) conforming to IS-2141/1979 grade- I, IS:4826-1979 & IS:6594-1974 or latest version thereof with tensile grade 4 & having minimum tensile strenght of 700N/mm2, H.D.G.I. turn buckle made out of 16mm dia H.D.G.I. rod & H.D.G.I. angle of size ISA 50x50x6mm, eye bolt made out of 20mmdia H.D.G.I. rod with 40mm dia inner dia eye at one end & threaded up to 300mm lenght from other side, along with H.D.G.I. hexagonal nuts suitable for above rod , break insulator of 16KV & minimum failing load of 44KN, & along with suitable H.D.G.I. stay clamps suitable for 9 mts RCC pole, H.D.G.I. nut bolts & of specifications as specified in drg nos. CEE/E-797, CEE/E-466, CEE/E-524, CEE/E-523 & CEE/E-711

5

12269

2453.88

... More
Erection of HDGI structure material for DPS. Each trasformer centre DP consist of HDGI structure material as follows: a) GI channel ISMC 75x40x7.3mm 2.75 mtrs long 2 pieces for incoming line & installation of disc insulators b) GI channel ISMC75x40x7.3mm 2.75mtrs long 2 pieces for GOAB switch c) GI channel ISMC 75x40x7.3mm 2.75 mtrs long 2 pieces for HG fuses d) GI channel ISMC 75x40x7.3mm 2.75 mtrs long 2 pieces for installation of lightening arrestor e) GI channel ISMC 100x50x7.3mm 2.75 mtrs long 2 pieces for installation of Trasformer f) GI channel ISMC 75x40x7.3mm 2.75 mtrs long 2 pieces for side support of trasformer g) GI channel ISMC 75x40x7.3mm 2.75 mtrs long 4 pieces for installation of any other items h) GI channel ISMC 100x40x7.3mm 0.52 mtrs long 2 pieces for installation of Transformer base channel

274

12878

47

... More
Erection of 11 KV , 200 A Horn gap fuse unit (Set of three) shall be as per enclosed drg No. CEE/E-786. Revision 3 and detailed specifications enclosed herewith.

1

3368

3368

... More
Erection of 11 KV rated voltange GOAB switches tilting type, outdoor, manually operated, triple pole, single break, conforming to IS: 9921-Part 1 to V as amended up to date and detailed specification eclosed herewith. Each set shall comprise of six pedestal and three tilting post insulators. Insulator should be factory cemented by the manufacturer of the insulators and have minimum 320 mm creepage distance and AB switchs contacts shall be of copper/ copper alloy. The AB switch shall be of following current rating: 200 A

1

3971

3971

... More
Erection of 9 KV, 5 KA nominal discharge current metal oxide gapless distribution class Lightning arrestor conforming to IEC-600994-4 and IS: 3070 part 3 1993 as amended upto date suitable for 11 KV 50 HZ effectively earthed neutral system with necessary mounting arragements and connector suitable to connect ASCR conductor upto overall diameter 12.30 mm

3

522

174

... More
Erection of Distribution Transformer 200 KVA 11/0.44 KVA Aluminium wound Star rated

1

15638

15638

... More
Erection of MS Distribution box as per drg No. CEE/E-689 Revision No. 3 along with MCCB 400 A, Bus bar made out of Aluminium strips 40 x 10 mm,aluminium 'J' type fuse links (Set of 3) for 4 feeder arrangement with 1 no of moulded case circuit breaker (MCCB) of 400A, 415V, AC 50 Hz for 200 KVA Distribution Transformer centre

1

8795

8795

... More
Erection of Distribution Transformer Metering unit with DLMS/COSEM protocol energy meter with modem

1

1072

1072

... More
Erection of ACSR 'Weasel' conductor confirming ISI specification IS: 398 (part-1/96) as amended upto date of following sizes 6/1/2.59 mm for guarding

0.3

2133

7110

... More
Erection of Single core XLPE Insulated PVC Sheathed cable 185sqmm 1.1kV grade

40

7360

184

... More
Erection of Single core XLPE Insulated PVC Sheathed cable 95sqmm 1.1kV grade

120

13920

116

... More
Erection of Three and half core armoured XLPE cable of size 95 Sq.mm cross linked polyethelene insulated, PVC shealthed 3.5 core 95 sqmm cable with galvanized steel strip armoured aluminium cable of 1100 volts grade suitable for 3 phase earthed system and conforming to IS: 7098 (Part-I)/1988 as amended upto date.

24

3576

149

... More
Erection of Enamelled danger boards 11000 Volts as per drg no. CEE/E-490

2

114

57

... More
Erection of HDGI earthing pipe 8ft long 40mm. Dia. Class B fabricated & perforated including alternate layers of 30cms thick of charcoal,salt & earth( charcoal & salt 10kgs each per pit inclusive of excavation,bacfilling& spreading the earth evenly)with brick masonary.

6

15990

2665

... More
Erection of Anti climbing device alongwith suitable two stay clamps & two pairs of H.D.G.I nuts bolts as per drg No. CEE/E-478

2

296

148

... More
Erection of FRP Fencing complete with Gate as per specification for Distribution Transformer (3Mx3Mx2M) with concreting for FRP fencing supports with plinth (0.3x0.3x0.5) Cu.mx12 nos. Each ratio 1;3;6

1

33667

33667

... More
Erection of HDGI L.T. 4 pin cross arm Channel type made of ISMC 75x40x7.3mm as per drg No.CEE/E-491

11

2871

261

... More
Erection of HDGI L.T. 2 pin cross arm Channel type made of ISMC 75x40x7.3mm as per drg No.CEE/E-491

6

1392

232

... More
Erection of HDGI X arm clamp for Rcc pole 9mtr S.A

8

360

45

... More
Erection of HDGI X arm clamp for Rcc pole 9mtr L.A

9

405

45

... More
Erection of G.I. Nuts & Bolts 100 X 16 mm

10

300

30

... More
Erection of LT brown glazed shackle Insulator of size 100 mm x 115 mm conforming to fig No. 4 and type 2 fo IS: 1445/77 as amended upto date. Minimum failing load shall be 16 KN with GI hardware suitable for LT shackle insulator of size 100 x 115 mm conforming to type 2 fig 4 of IS: 1445/77 as amended upto date. Hardware or fitting shall conform to fig 4 of IS: 7935-1975 as amended upto date comprise fo 2 GI strips, 2 GI bolts and 2 nuts with spring washers.

64

13312

208

... More
Erection of L.T. brown glazed porcelain pin insulators of size 100mmx70mm conforming to type 1 fig 1 of IS: 1445/1977 with amendment 2 of Feb 1981 (second revision) as amended upto date. Minimum failing load shall be 3.5 KN with Forged GI pin conforming to IS 7935/1975 as amended upto date suitable for LT porcelain pin insulator type 1 conforming to fig 1 of IS: 1445/77 with amendment no 2 feb 1981, of size 100 x 70 mm. GI pin shall comprise of GI nut and spring washer and conform to fig No 2 of IS: 7935/1975. Minimum failing load of pin shall be 3.5 KN

10

1730

173

... More
Erection of AAC conductor hard drawn stranded all aluminium conductor conforming IS 398(Part-1/96) as amended upto date of following sizes 7/3.10 mm ANT conductor for phases

0.73

4842

6634

... More
Erection of AAC conductor hard drawn stranded all aluminium conductor conforming IS 398(Part-1/96) as amended upto date of following sizes 7/2.21 mm GNAT conductor for double neutral & guadings.

0.39

2411

6183

... More
Removing of RCC pole 7.5 mtr as per the drawing No.CEE/E-565 REV-3 as per annexure confirming to IS 785-1998 as amended upto date. The component used for pole shall conform to following IS amended up to date. 1) Ordinary Port land cement 53 grade IS 12269 2) Aggregate IS 383-1970 3) Torsteel IS 1786-7985 4) MS bar IS 432 p 1 & 2-1982

1

1844

1844.5

... More
Removing HDG L.T. 4 pin cross arm Channel type made of ISMC 75x40x7.3mm as per drg No.CEE/E-491

1

130

130.5

... More
Removing of HDG L.T. 2 pin cross arm Channel type made of ISMC 75x40x7.3mm as per drg No.CEE/E-491

1

116

116

... More
Removing of LT brown glazed shackle Insulator of size 100 mm x 115 mm conforming to fig No. 4 and type 2 fo IS: 1445/77 as amended upto date. Minimum failing load shall be 16 KN with GI hardware suitable for LT shackle insulator of size 100 x 115 mm conforming to type 2 fig 4 of IS: 1445/77 as amended upto date. Hardware or fitting shall conform to fig 4 of IS: 7935-1975 as amended upto date comprise fo 2 GI strips, 2 GI bolts and 2 nuts with spring washers.

10

1040

104

... More
Removing & Restringing of AAC conductor hard drawn stranded all aluminium conductor conforming IS 398(Part-1/96) as amended upto date of following sizes 7/3.10 mm ANT conductor for phases

0.6

5970

9951

... More
Removing & Restringing of AAC conductor hard drawn stranded all aluminium conductor conforming IS 398(Part-1/96) as amended upto date of following sizes 7/2.21 mm GNAT conductor for double neutral & guadings.

0.65

6028

9274.5

... More
Removing LT pin insulator

10

865

86.5



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.