Electricity Department Tender

View complete overview of Goa Electricity Department Tender

Electricity Department Tender

Works
Civil And Construction
Electrical and Electronics
Water Storage And Supply
Eprocure
Opening Date6 Nov 2024
Closing Soon18 Nov 2024
Tender Amount₹ 55,25,841 
Notes
Download

Costs

  • EMD

    ₹ 1,10,517
  • Document Cost

    ₹ 1,000
  • Tender Fee

    ₹ 6,000

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
Single core XLPE Insulated PVC Sheathed cable 185sqmm 1.1kV grade

80

245

19600

... More
Single core XLPE Insulated PVC Sheathed cable 95sqmm 1.1kV grade

100

128

12800

... More
Three and half core armoured XLPE cable of size 95 Sq.mm cross linked polyethelene insulated, PVC shealthed 3.5 core 95 sqmm cable with galvanized steel strip armoured aluminium cable of 1100 volts grade suitable for 3 phase earthed system and conforming to IS: 7098 (Part-I)/1988 as amended upto date.

72

734

52848

... More
HDG earthing pipe 8ft long 40mm. Dia. Class B fabricated & perforated including alternate layers of 30cms thick of charcoal,salt & earth( charcoal & salt 10kgs each per pit inclusive of excavation,bacfilling& spreading the earth evenly)

12

2730

32760

... More
9 KV, 5 KA nominal discharge current metal oxide gapless distribution class Lightning arrestor conforming to IEC-600994-4 and IS: 3070 part 3 1993 as amended upto date suitable for 11 KV 50 HZ effectively earthed neutral system with necessary mounting arragements and connector suitable to connect ASCR conductor upto overall diameter 12.30 mm

6

3033

18198

... More
FRP Fencing complete with Gate as per specification for Distribution Transformer (3Mx3Mx2M) with concreting for FRP fencing supports with plinth (0.3x0.3x0.5) Cu.mx12 nos. Each ratio 1;3;6

2

76667

153334

... More
ACSR 'Weasel' conductor confirming ISI specification IS: 398 (part-1/96) as amended upto date of following sizes 6/1/2.59 mm for guarding

0.1

33409

3340.9

... More
HDGI structure material for 12 DPS. Each trasformer centre DP consist of HDGI structure material as follows: a) GI channel ISMC 75x40x7.3mm 2.75 mtrs long 2 pieces for incoming line & installation of disc insulators b) GI channel ISMC75x40x7.3mm 2.75mtrs long 2 pieces for GOAB switch c) GI channel ISMC 75x40x7.3mm 2.75 mtrs long 2 pieces for HG fuses d) GI channel ISMC 75x40x7.3mm 2.75 mtrs long 2 pieces for installation of lightening arrestor e) GI channel ISMC 100x50x7.3mm 2.75 mtrs long 2 pieces for installation of Trasformer f) GI channel ISMC 75x40x7.3mm 2.75 mtrs long 2 pieces for side support of trasformer g) GI channel ISMC 75x40x7.3mm 2.75 mtrs long 4 pieces for installation of any other items h) GI channel ISMC 100x40x7.3mm 0.52 mtrs long 2 pieces for installation of Transformer base channel

548

169

92612

... More
11 KV , 200 A Horn gap fuse unit (Set of three) shall be as per enclosed drg No. CEE/E-786. Revision 3 and detailed specifications enclosed herewith.

2

10450

20900

... More
11 KV rated voltange GOAB switches tilting type, outdoor, manually operated, triple pole, single break, conforming to IS: 9921-Part 1 to V as amended up to date and detailed specification eclosed herewith. Each set shall comprise of six pedestal and three tilting post insulators. Insulator should be factory cemented by the manufacturer of the insulators and have minimum 320 mm creepage distance and AB switchs contacts shall be of copper/ copper alloy. The AB switch shall be of following current rating: 200 A

2

23535

47070

... More
Erection of RCC pole 9.0 mtr as per the drawing No.CEE/E-698, REV-1 as per annexure confirming to IS 785-1998 as amended upto date. The component used for pole shall conform to following IS amended up to date. 1) Ordinary Port land cement 53 grade IS 12269 2) Aggregate IS 383-1970 3) Torsteel IS 1786-7985 4) MS bar IS 432 p 1 & 2-1982

20

8386

167720

... More
Erection of RCC pole 7.5 mtr as per the drawing No.CEE/E-698, REV-1 as per annexure confirming to IS 785-1998 as amended upto date. The component used for pole shall conform to following IS amended up to date. 1) Ordinary Port land cement 53 grade IS 12269 2) Aggregate IS 383-1970 3) Torsteel IS 1786-7985 4) MS bar IS 432 p 1 & 2-1982

23

6092

140116

... More
H.D.G.I. stay rod of 1200mm long & 16mm dia with an eye band of internal dia 40mm at one end & threaded up to length of 200mm at the other end, H.D.G.I. stay plate 450x450x8mm size with a hole for at the centre to suit above stay rod, H.D.G.I. stay wire of size 7/5.15mm (7/8SWG) conforming to IS-2141/1979 grade- I, IS:4826-1979 & IS:6594-1974 or latest version thereof with tensile grade 4 & having minimum tensile strenght of 700N/mm2, H.D.G.I. turn buckle made out of 16mm dia H.D.G.I. rod & H.D.G.I. angle of size ISA 50x50x6mm, eye bolt made out of 20mmdia H.D.G.I. rod with 40mm dia inner dia eye at one end & threaded up to 300mm lenght from other side, along with H.D.G.I. hexagonal nuts suitable for above rod , break insulator of 16KV & minimum failing load of 44KN, & along with suitable H.D.G.I. stay clamps suitable for 7.5 mts RCC pole, H.D.G.I. nut bolts & of specifications as specified in drg nos. CEE/E-797, CEE/E-466, CEE/E-524, CEE/E-523 & CEE/E-711

24

3976

95445.6

... More
H.D.G.I. stay rod of 1200mm long & 16mm dia with an eye band of internal dia 40mm at one end & threaded up to length of 200mm at the other end, H.D.G.I. stay plate 450x450x8mm size with a hole for at the centre to suit above stay rod, H.D.G.I. stay wire of size 7/5.15mm (7/8SWG) conforming to IS-2141/1979 grade- I, IS:4826-1979 & IS:6594-1974 or latest version thereof with tensile grade 4 & having minimum tensile strenght of 700N/mm2, H.D.G.I. turn buckle made out of 16mm dia H.D.G.I. rod & H.D.G.I. angle of size ISA 50x50x6mm, eye bolt made out of 20mmdia H.D.G.I. rod with 40mm dia inner dia eye at one end & threaded up to 300mm lenght from other side, along with H.D.G.I. hexagonal nuts suitable for above rod , break insulator of 16KV & minimum failing load of 44KN, & along with suitable H.D.G.I. stay clamps suitable for 9 mts RCC pole, H.D.G.I. nut bolts & of specifications as specified in drg nos. CEE/E-797, CEE/E-466, CEE/E-524, CEE/E-523 & CEE/E-711

9

4275

38478.06

... More
HDG L.T. 4 pin cross arm Channel type made of ISMC 75x40x7.3mm as per drg No.CEE/E-492 with clamp and nut bolt for 7.5 mtr Rcc pole

91

1109

100919

... More
HDG L.T. 2 pin cross arm Channel type made of ISMC 75x40x7.3mm as per drg No.CEE/E-491 with clamp and nut bolt for 7.5 mtr Rcc pole

71

569

40399

... More
HDGI 'X' arm clamps for RCC Pole 7.5 mtr L.A. (Dimensions/specifications as per drawing no. CEE/E-523)

89

184

16376

... More
HDGI 'X' arm clamps for RCC Pole 9.00 mtr L.A., (Dimensions/specifications as per drawing no. CEE/E-524)

71

266

18886

... More
G.I nut & Bolt100x16mm (Galvanising should be hot dipped Galvanised as per IS:2629/66, minimum Zinc coating of 1000 gms/sq.mtr, 140 Microns DFT), suitable for high salinity coastal areas)

68

228

15504

... More
L.T. brown glazed porcelain pin insulators of size 100mmx70mm conforming to type 1 fig 1 of IS: 1445/1977 with amendment 2 of Feb 1981 (second revision) as amended upto date. Minimum failing load shall be 3.5 KN with Forged GI pin conforming to IS 7935/1975 as amended upto date suitable for LT porcelain pin insulator type 1 conforming to fig 1 of IS: 1445/77 with amendment no 2 feb 1981, of size 100 x 70 mm. GI pin shall comprise of GI nut and spring washer and conform to fig No 2 of IS: 7935/1975. Minimum failing load of pin shall be 3.5 KN

156

263

41028

... More
LT brown glazed shackle Insulator of size 100 mm x 115 mm conforming to fig No. 4 and type 2 fo IS: 1445/77 as amended upto date. Minimum failing load shall be 16 KN with GI hardware suitable for LT shackle insulator of size 100 x 115 mm conforming to type 2 fig 4 of IS: 1445/77 as amended upto date. Hardware or fitting shall conform to fig 4 of IS: 7935-1975 as amended upto date comprise fo 2 GI strips, 2 GI bolts and 2 nuts with spring washers.

392

372

145824

... More
AAC conductor hard drawn stranded all aluminium conductor conforming IS 398(Part-1/96) as amended upto date of following sizes 7/3.10 mm ANT conductor for phases

8.23

48086

395747.78

... More
AAC conductor hard drawn stranded all aluminium conductor conforming IS 398(Part-1/96) as amended upto date of following sizes 7/2.21 mm GNAT conductor for double neutral & guadings.

6.75

25293

170727.75

... More
Supply, laying, Testing & commissioning of 11KV, 3 core 95sq.mm A2XFY Aluminium Armoured XLPE Cable through conventional open trenching method in any type of soil including hard laterite.

25

1127

28175

... More
Supply, Erection, Testing & Commissioning of of 11 KV Termination kit Outdoor 3 core 95 sqmm XLPE

2

10152

20304

... More
Supply, Erection, Testing & Commissioning of of 11 KV Termination kit indoor 3 core 95 sqmm XLPE

2

6731

13462

... More
Supply, Erection, Testing & Commissioning of of 11 KV Termination kit indoor 3 core 300 sqmm XLPE

55

8840

486200

... More
3 WAY RMU, 11KV, 630A, 21 kA 3Sec, SF6 Outdoor RMU – 2LBS + 1CB Extensible/Non-Extensible Two (2) Motor operated load break switches (LBSs) with Manual operated earthing switches in SF6 and One (1) vacuum circuit breaker with Electrical closing and tripping along with disconnector and earthing switches SCADA Compatible and base channel. Battery charger along with batteries required for Electrical operations of RMU is in the scope of the Bidder. Each module shall consist of VPIS, FPI in LBS Module (N-1) but not less than 1 no’s per RMU. Suitable arrangement for mounting FRTU, modem or Ethernet Switch/LIU along with battery, battery charger shall be provided in RMU.

2

565000

1130000

... More
Cost of Erection

-

-

-

... More
Distribution Transformer 200 KVA 11/0.44 KVA Aluminium wound Star rated

2

15638

31276

... More
MS Distribution box as per drg No. CEE/E-689 Revision No. 3 along with MCCB 400 A, Bus bar made out of Aluminium strips 40 x 10 mm,aluminium 'J' type fuse links (Set of 3) for 4 feeder arrangement with 1 no of moulded case circuit breaker (MCCB) of 400A, 415V, AC 50 Hz for 200 KVA Distribution Transformer centre

2

8795

17590

... More
Single core XLPE Insulated PVC Sheathed cable 185sqmm 1.1kV grade

80

170

13600

... More
Single core XLPE Insulated PVC Sheathed cable 95sqmm 1.1kV grade

100

91

9100

... More
Three and half core armoured XLPE cable of size 95 Sq.mm cross linked polyethelene insulated, PVC shealthed 3.5 core 95 sqmm cable with galvanized steel strip armoured aluminium cable of 1100 volts grade suitable for 3 phase earthed system and conforming to IS: 7098 (Part-I)/1988 as amended upto date.

72

149

10728

... More
HDG earthing pipe 8ft long 40mm. Dia. Class B fabricated & perforated including alternate layers of 30cms thick of charcoal,salt & earth( charcoal & salt 10kgs each per pit inclusive of excavation,bacfilling& spreading the earth evenly)

12

2444

29328

... More
9 KV, 5 KA nominal discharge current metal oxide gapless distribution class Lightning arrestor conforming to IEC-600994-4 and IS: 3070 part 3 1993 as amended upto date suitable for 11 KV 50 HZ effectively earthed neutral system with necessary mounting arragements and connector suitable to connect ASCR conductor upto overall diameter 12.30 mm

6

174

1044

... More
FRP Fencing complete with Gate as per specification for Distribution Transformer (3Mx3Mx2M) with concreting for FRP fencing supports with plinth (0.3x0.3x0.5) Cu.mx12 nos. Each ratio 1;3;6

2

35000

70000

... More
ACSR 'Weasel' conductor confirming ISI specification IS: 398 (part-1/96) as amended upto date of following sizes 6/1/2.59 mm for guarding

0.1

11000

1100

... More
HDGI structure material for 12 DPS. Each trasformer centre DP consist of HDGI structure material as follows: a) GI channel ISMC 75x40x7.3mm 2.75 mtrs long 2 pieces for incoming line & installation of disc insulators b) GI channel ISMC75x40x7.3mm 2.75mtrs long 2 pieces for GOAB switch c) GI channel ISMC 75x40x7.3mm 2.75 mtrs long 2 pieces for HG fuses d) GI channel ISMC 75x40x7.3mm 2.75 mtrs long 2 pieces for installation of lightening arrestor e) GI channel ISMC 100x50x7.3mm 2.75 mtrs long 2 pieces for installation of Trasformer f) GI channel ISMC 75x40x7.3mm 2.75 mtrs long 2 pieces for side support of trasformer g) GI channel ISMC 75x40x7.3mm 2.75 mtrs long 4 pieces for installation of any other items h) GI channel ISMC 100x40x7.3mm 0.52 mtrs long 2 pieces for installation of Transformer base channel

548

47

25756

... More
11 KV , 200 A Horn gap fuse unit (Set of three) shall be as per enclosed drg No. CEE/E-786. Revision 3 and detailed specifications enclosed herewith.

2

3368

6736

... More
11 KV rated voltange GOAB switches tilting type, outdoor, manually operated, triple pole, single break, conforming to IS: 9921-Part 1 to V as amended up to date and detailed specification eclosed herewith. Each set shall comprise of six pedestal and three tilting post insulators. Insulator should be factory cemented by the manufacturer of the insulators and have minimum 320 mm creepage distance and AB switchs contacts shall be of copper/ copper alloy. The AB switch shall be of following current rating: 200 A

2

3971

7942

... More
Erection of RCC pole 9.0 mtr as per the drawing No.CEE/E-698, REV-1 as per annexure confirming to IS 785-1998 as amended upto date. The component used for pole shall conform to following IS amended up to date. 1) Ordinary Port land cement 53 grade IS 12269 2) Aggregate IS 383-1970 3) Torsteel IS 1786-7985 4) MS bar IS 432 p 1 & 2-1982

20

5900

118000

... More
Erection of RCC pole 7.5 mtr as per the drawing No.CEE/E-698, REV-1 as per annexure confirming to IS 785-1998 as amended upto date. The component used for pole shall conform to following IS amended up to date. 1) Ordinary Port land cement 53 grade IS 12269 2) Aggregate IS 383-1970 3) Torsteel IS 1786-7985 4) MS bar IS 432 p 1 & 2-1982

23

5200

119600

... More
H.D.G.I. stay rod of 1200mm long & 16mm dia with an eye band of internal dia 40mm at one end & threaded up to length of 200mm at the other end, H.D.G.I. stay plate 450x450x8mm size with a hole for at the centre to suit above stay rod, H.D.G.I. stay wire of size 7/5.15mm (7/8SWG) conforming to IS-2141/1979 grade- I, IS:4826-1979 & IS:6594-1974 or latest version thereof with tensile grade 4 & having minimum tensile strenght of 700N/mm2, H.D.G.I. turn buckle made out of 16mm dia H.D.G.I. rod & H.D.G.I. angle of size ISA 50x50x6mm, eye bolt made out of 20mmdia H.D.G.I. rod with 40mm dia inner dia eye at one end & threaded up to 300mm lenght from other side, along with H.D.G.I. hexagonal nuts suitable for above rod , break insulator of 16KV & minimum failing load of 44KN, & along with suitable H.D.G.I. stay clamps suitable for 7.5 mts RCC pole, H.D.G.I. nut bolts & of specifications as specified in drg nos. CEE/E-797, CEE/E-466, CEE/E-524, CEE/E-523 & CEE/E-711

24

2391

57403.2

... More
H.D.G.I. stay rod of 1200mm long & 16mm dia with an eye band of internal dia 40mm at one end & threaded up to length of 200mm at the other end, H.D.G.I. stay plate 450x450x8mm size with a hole for at the centre to suit above stay rod, H.D.G.I. stay wire of size 7/5.15mm (7/8SWG) conforming to IS-2141/1979 grade- I, IS:4826-1979 & IS:6594-1974 or latest version thereof with tensile grade 4 & having minimum tensile strenght of 700N/mm2, H.D.G.I. turn buckle made out of 16mm dia H.D.G.I. rod & H.D.G.I. angle of size ISA 50x50x6mm, eye bolt made out of 20mmdia H.D.G.I. rod with 40mm dia inner dia eye at one end & threaded up to 300mm lenght from other side, along with H.D.G.I. hexagonal nuts suitable for above rod , break insulator of 16KV & minimum failing load of 44KN, & along with suitable H.D.G.I. stay clamps suitable for 9 mts RCC pole, H.D.G.I. nut bolts & of specifications as specified in drg nos. CEE/E-797, CEE/E-466, CEE/E-524, CEE/E-523 & CEE/E-711

9

2453

22084.92

... More
HDG L.T. 4 pin cross arm Channel type made of ISMC 75x40x7.3mm as per drg No.CEE/E-492 with clamp and nut bolt for 7.5 mtr Rcc pole

91

261

23751

... More
HDG L.T. 2 pin cross arm Channel type made of ISMC 75x40x7.3mm as per drg No.CEE/E-491 with clamp and nut bolt for 7.5 mtr Rcc pole

71

232

16472

... More
HDGI 'X' arm clamps for RCC Pole 7.5 mtr L.A. (Dimensions/specifications as per drawing no. CEE/E-523)

89

32

2848

... More
HDGI 'X' arm clamps for RCC Pole 9.00 mtr L.A., (Dimensions/specifications as per drawing no. CEE/E-524)

71

45

3195

... More
G.I nut & Bolt100x16mm (Galvanising should be hot dipped Galvanised as per IS:2629/66, minimum Zinc coating of 1000 gms/sq.mtr, 140 Microns DFT), suitable for high salinity coastal areas)

68

30

2040

... More
L.T. brown glazed porcelain pin insulators of size 100mmx70mm conforming to type 1 fig 1 of IS: 1445/1977 with amendment 2 of Feb 1981 (second revision) as amended upto date. Minimum failing load shall be 3.5 KN with Forged GI pin conforming to IS 7935/1975 as amended upto date suitable for LT porcelain pin insulator type 1 conforming to fig 1 of IS: 1445/77 with amendment no 2 feb 1981, of size 100 x 70 mm. GI pin shall comprise of GI nut and spring washer and conform to fig No 2 of IS: 7935/1975. Minimum failing load of pin shall be 3.5 KN

156

173

26988

... More
LT brown glazed shackle Insulator of size 100 mm x 115 mm conforming to fig No. 4 and type 2 fo IS: 1445/77 as amended upto date. Minimum failing load shall be 16 KN with GI hardware suitable for LT shackle insulator of size 100 x 115 mm conforming to type 2 fig 4 of IS: 1445/77 as amended upto date. Hardware or fitting shall conform to fig 4 of IS: 7935-1975 as amended upto date comprise fo 2 GI strips, 2 GI bolts and 2 nuts with spring washers.

392

208

81536

... More
AAC conductor hard drawn stranded all aluminium conductor conforming IS 398(Part-1/96) as amended upto date of following sizes 7/3.10 mm ANT conductor for phases

8.23

10300

84769

... More
AAC conductor hard drawn stranded all aluminium conductor conforming IS 398(Part-1/96) as amended upto date of following sizes 7/2.21 mm GNAT conductor for double neutral & guadings.

6.75

9100

61425

... More
Supply, laying, Testing & commissioning of 11KV, 3 core 95sq.mm A2XFY Aluminium Armoured XLPE Cable through conventional open trenching method in any type of soil including hard laterite.

25

199

4975

... More
Supply, Erection, Testing & Commissioning of of 11 KV Termination kit Outdoor 3 core 95 sqmm XLPE

2

2648

5296

... More
Supply, Erection, Testing & Commissioning of of 11 KV Termination kit indoor 3 core 95 sqmm XLPE

2

2538

5076

... More
Supply, Erection, Testing & Commissioning of of 11 KV Termination kit indoor 3 core 300 sqmm XLPE

55

2548

140140

... More
3 WAY RMU, 11KV, 630A, 21 kA 3Sec, SF6 Outdoor RMU – 2LBS + 1CB Extensible/Non-Extensible Two (2) Motor operated load break switches (LBSs) with Manual operated earthing switches in SF6 and One (1) vacuum circuit breaker with Electrical closing and tripping along with disconnector and earthing switches SCADA Compatible and base channel. Battery charger along with batteries required for Electrical operations of RMU is in the scope of the Bidder. Each module shall consist of VPIS, FPI in LBS Module (N-1) but not less than 1 no’s per RMU. Suitable arrangement for mounting FRTU, modem or Ethernet Switch/LIU along with battery, battery charger shall be provided in RMU.

2

9720

19440

... More
Removing 7.5 mtr Rcc pole

12

2600

31200

... More
Removing 9 mtr Rcc pole

1

2950

2950

... More
Removing 4 pin Xarm

49

113

5561.5

... More
Removing 2 pin Xarm

29

97

2827.5

... More
Removing LT pin Insulator

76

86

6574

... More
Removing LT Shackle Insulator

193

104

20072

... More
Removing ANT conductor

3.36

5150

17304

... More
Removing GNAT conductor

4.45

4550

20247.5



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements

Past Bidders
This list is curated from the bidders of the similar tenders in the past

Unlock the Tender details for free
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.