Electricity Department Tender

View complete overview of Goa Electricity Department Tender

Electricity Department Tender

Works
Electrical and Electronics
Electrical Works
Eprocure
Opening Date15 Jan 2024
Closing Date6 Feb 2024
Tender Amount₹ 48,32,954 
Notes
Download

Costs

  • EMD

    ₹ 96,659
  • Document Cost

    ₹ 1,500
  • Tender Fee

    ₹ 6,000

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
Supply of Stay set complete for 9.0 mts RCC Pole.HDGI Stay Sets Complete Comprising of stay rod with plate, HDGI stay wire of size 7/10swg, Break insulator of 15KV/8KV,HDGI turn buckle with eye bolt, suitable HDGI stay clamps, HDGI nut bolts, . The Stay wire shall comply with the specific requirements of IS: 2141-1979, IS: 4826-1979 & IS: 6594-1974 or the latest versions thereof and also as per the specifications enclosed.

8

34936

4367

... More
Supply of Stay set complete for 7.5 mts RCC Pole.HDGI Stay Sets Complete Comprising of stay rod with plate, HDGI stay wire of size 7/10swg, Break insulator of 15KV/8KV,HDGI turn buckle with eye bolt, suitable HDGI stay clamps, HDGI nut bolts, . The Stay wire shall comply with the specific requirements of IS: 2141-1979, IS: 4826-1979 & IS: 6594-1974 or the latest versions thereof and also as per the specifications enclosed.

3

12204

4068

... More
Supply of HDGI nuts & bolts.G.I. Hexagonal head bolts and hexagonal nuts conforming to IS 1363 part 1 to 3 1992 as amended upto date.The bolts and nuts shall be hot dip galvanized as per IS: 2629-1985 as amended upto date, Size-100x16 mm

26

5928

228

... More
Supply & Providing of Cement concrete in the ratio 1:2:4(1 cement: 2 Sand, 4 graded granite/basaltic, aggregate 20mm nominal size) including cost of centering, shuttering & muffing 0.4mts above the ground & properly curved

8.2

45551

5555

... More
Supply of Enamelled danger board of size 250mm x 200mm, 440Volts/11000 Volts/3300 Volts: The plate should be made from mild steel at least 1.6mm thick and vitreous enamelled white with letters, figures and convectional skull & bones in signal red colour on the front side. The rear side of the plate shall be enamelled. All letters should be centrally spaced. The corners of the plate should be rounded .

2

496

248

... More
Supply of Anticlimbing device(barbed wire).Hot dip galvanized steel barbed wire type 4 conforming to IS:278/1962 as amended upto date and galvanization conforming to IS:4826/1979as amended upto date. (Galvanising should be hot dippped Galvanised as per IS:2629/66, minimum Zinc coating of 1000gms/sq.mtr, 140 Microns DFT), suitable for high salinity coastal areas. Nominal diameter of line wire and point wire shall be 2.24mm each. Nominal distance between two barbs shall be 150mm. Tests as per IS shall be carried out at manufacturars work & test reports shall be furnished before supply of materials.

2

290

145

... More
Supply of HDGI Structure Materials. shall be hot dipped galvanized

274

46306

169

... More
Supply of GI stay clamp LA for 9.0mts pole.shall be hot dipped galvanized generally conforming to IS - 2633/73

10

4910

491

... More
Supply of GI Xarm clamp SA for 9.0mts pole.shall be hot dipped galvanized generally conforming to IS - 2633/73

12

3192

266

... More
Supply of GI Xarm clamp LA for 9.0mts pole.shall be hot dipped galvanized generally conforming to IS - 2633/72

18

4788

266

... More
Supply of 11KV Disc insulator with metal parts.11 KV disc insulators ball and socket type, type ‘A’ porcelain brown glazed duly cemented at factory with MCI socket cap, forged steel ball pin and supplied with Phosphor bronze “W” split pin as per IS 731-1971 as amended upto date. Minimum failing load. 45 KN.Pin ball diameter 16 mm.3-bolted type hardware fitting suitable for 11KV ball and socket type disc insulators of 16mm pin, failing load of 45KN and suitable for ACSR WEASEL conductor

3

7095

2365

... More
Supply of 11KV pin insulator with Gi pin.11 KV brown glazed porcelain pin insulator with minimum failing load of 5 KN and the Minimum creepage distance of 320 mm .Forged G. I. Pin conforming to IS 2486 part 1 & 2 as amended upto date

3

2079

693

... More
Supply of 11 KV GOAB switch with 200 A.12 KV rated voltage GOAB switches tilting type, outdoor, manually operated, triple pole, single break, conforming to IS: 9921-Part1 to V as amended upto date and detailed specifications enclosed herewith. Each set shall comprise of six pedestal and three tilting post insulators. Insulator should be factory cemented by the manufactures of the insulators and have minimum 320mm creepage distance and AB switches contacts shall be of copper/copper alloy

1

23535

23535

... More
Supply of Earthing complete with 2.5mts long, 40mm GI earthing pipe, class B, 20kgs each of salt and charcoal, excvation, re-filling etc.Earthing pipe made of Hot Dip galvanized steel tube of heavy class, 40mm nominal bore conforming to IS 1239 Part 1 1990 as amended upto date and Hot Dip zinc coating shall conform to IS 4736-1968 as amended upto date

6

16380

2730

... More
Supply of ACSR 'WEASEL' of size ( 6/1/2.59mm) for earthing and jumpering .Packing and marking of drum will be as per IS:Conductor length shall be 1500 mtr. with tolerance of +/- 5%

0.13

4176

33409

... More
Supply of 11 KV HG fuse,200A, Horn gap type fuse I.TECHNICAL PARTICULARS: 1. Highest System voltage : 12 KV (R.M.S) 2. Impulse voltage withstand voltage : 75 KV (Peak) 3. One minute power frequency withstand voltage : 35 KV (R.M.S.) 4. Continuous current rating of the unit : 200 Amps

1

10450

10450

... More
Supply of 9 KV, 5A Lightning Arrestor, pole mounted.9 KV, 5 KA nominal discharge current Metal Oxide gapless distribution class lightning arrestor conforming to IEC-60099-4 and IS 3070 Part 3 1993 as amended upto date suitable for 11 KV 50 HZ effectively earthed neutral system with necessary mounting arrangements and connector suitable to connect ACSR conductor upto overall diameter 12.30 mm.The marking of the Lightning Arrestors shall be as per IS

3

9099

3033

... More
Supply of MS Distribution box complete.M. S. distribution box MCCB of 400 Amps capacity Kit Kat Porcelain fuse carrier and base with extended terminals.

1

63140

63140

... More
Supply & Fixing of DTC metering unit

1

25688

25688

... More
Supply CCMS Panel for street light 3 phase

1

34483

34483

... More
Supply of XLPE unarmoured cable 3 & half core 120 sq.mm.The unarmoured cable shall be of 1 core and of sizes as required i.e.120Sq.mm that shall be suitably terminated at both the ends with appropriate sizes of Aluminum lugs duly crimped using a crimping tool. Appropriate sizes of G.I / Brass nut / bolts / washers shall be used for firmly connecting the same to the MCCB’s/Transformer L.T. Bushings/Outgoing LT feeder

10

9130

913

... More
Supply of XLPE unarmoured cable 3 & half core 95 sq.mm.The unarmoured cable shall be of 1core and of sizes as required i.e.95 Sq.mm that shall be suitably terminated at both the ends with appropriate sizes of Aluminum lugs duly crimped using a crimping tool. Appropriate sizes of G.I / Brass nut / bolts / washers shall be used for firmly connecting the same to the MCCB’s/Transformer L.T. Bushings/Outgoing LT feeder

24

17616

734

... More
Supply of 100 KVA, Distribution transformer, 11KV/0.4KV with level-II losses, Alluminium Winding with Bimetallic Terminal connectors, Energy Efficiency Level-II as per IS:1180(Part-I):2014

1

247700

247700

... More
Supply of Aluminum crimping lugs shall conform to IS: 8309-1976 as amended upto date. Lugs shall be made of aluminium of grade 1E of IS 5082-1969 suitable for aluminium cables of following sizes: 1)120Sq.mm

6

324

54

... More
Supply of Aluminum crimping lugs shall conform to IS: 8309-1976 as amended upto date. Lugs shall be made of aluminium of grade 1E of IS 5082-1969 suitable for aluminium cables of following sizes: 1. 95 Sq.mm.

24

960

40

... More
Supply of Aluminum crimping lugs shall conform to IS: 8309-1976 as amended upto date. Lugs shall be made of aluminium of grade 1E of IS 5082-1969 suitable for aluminium cables of following sizes: 1. 70Sq.mm.

20

680

34

... More
Supply of conductor-AA ANT, 2. 7/3.10 mm .nominal aluminum area 50mm^2 (190 amps max. at 40 deg.C)

1.41

67801

48086

... More
Supply of conductor -AA GNAT,1. 7/2.21 mm,nominal aluminum area 25mm^2 (80 amps max. at 40 deg.C)

1.26

31869

25293

... More
Supply of Cross Arm Channel 4Pin .The cross arms shall be made of M.S. channel of ISMC-75 vide table 2 of IS: 8081 1964 . The cross arms shall be without any joints. The cross arms shall be hot dipped galvanized generally conforming to IS - 2633/72. The length of the 4pin cross arm shall be 1110mm with 4 holes of 22 dia each on each flange section. In addition 2 holes of size 18mm x 40mm slotted holes shall be provided on the cross arm for clamping arrangement to the pole. The length of the 4pin side cross arm shall be 1410mm with 4 holes of 22 dia each on each flange section. In addition 2 holes of size 18mm x 40mm slotted holes shall be provided on the cross arm 40 mm from the left edge of the X-arm for clamping arrangement to the pole & two holes of size 17mm dia at 355mm & 660mm from the slotted hole for arrangement to fix angle support. The angle support shall be of ISA 50x50x6mm G.I. with 17 mm dia holes at the two ends. The other end of the angle shall be clamps utilizing suitable G. I. stay clamps of length 312mm end to end

17

18853

1109

... More
Supply of Cross Arm Channel 2Pin .The cross arms shall be made of M.S. channel of ISMC-75 vide table 2 of IS: 8081 1964 . The cross arms shall be without any joints. The cross arms shall be hot dipped galvanized generally conforming to IS - 2633/72. The length of the 4pin cross arm shall be 1110mm with 4 holes of 22 dia each on each flange section. In addition 2 holes of size 18mm x 40mm slotted holes shall be provided on the cross arm for clamping arrangement to the pole. The length of the 4pin side cross arm shall be 1410mm with 4 holes of 22 dia each on each flange section. In addition 2 holes of size 18mm x 40mm slotted holes shall be provided on the cross arm 40 mm from the left edge of the X-arm for clamping arrangement to the pole & two holes of size 17mm dia at 355mm & 660mm from the slotted hole for arrangement to fix angle support. The angle support shall be of ISA 50x50x6mm G.I. with 17 mm dia holes at the two ends. The other end of the angle shall be clamps utilizing suitable G. I. stay clamps of length 312mm end to end

20

11380

569

... More
Supply of GI Xarm clamp SA for 7.5mts pole.shall be hot dipped galvanized generally conforming to IS - 2633/73

14

2576

184

... More
Supply of GI Xarm clamp LA for 7.5mts pole.shall be hot dipped galvanized generally conforming to IS - 2633/72

17

3128

184

... More
Supply of Insulator -(LT) Shackle .L.T. brown glazed shackle insulators of size 100mm x 115mm conforming to fig.No.4 and type 2 of IS: 1445/77 as amended upto date. Minimum failing load shall be 16kN. Insulators shall have marking and packing as prescribed in IS

48

12624

263

... More
Supply of LT pin insulator with GI pin

80

29760

372

... More
Supply of FRP Fencing complete with Gate around every distribution sub-station containing RMU, one distribution transformer and one LV switchboard including danger plate (Size  4Mx3Mx2M) with Concreting for FRP Fencing supports with plinth (0.3x0.3x0.5) Cu.m. x 12 nos. Each ratio 1:3:6

1

76667

76667

... More
Supply of 11KV, 3 core, 300 sq.mm. aluminium, XLPE insulated, flat wire armoured, 11 KV (Earthed) Cable

745

1741810

2338

... More
Supply of 11KV, 3 core 185sq.mm aluminium, XLPE insulated, flat wire armoured, 11 KV (Earthed) Cable

32

51040

1595

... More
Supply of 3 WAY RMU ,11KV, 630 Amps,21 kA, 3 sec, SF6 Outdoor RMU- 2 LBS+ 1 CB Extension/Non-Extendable Two(2) Motor operated load break switches (LBS) with Manual operated earthing switches in SF6 and One (1) vaccum circuir breaker with electrical closing and tripping along with disonnector and earthing switches SCADA Compatible and basic channel. Battery charger along woth batetried required for electrical opearations of RMU is in the scope of bidder .Each module shall consisit of VPIS,FPIin LBS Module(N-1) but not less than 1 nos per RMU. Suitable arranegment for mounting FRTU, modem or Ethernet Switch/LIU along with baterry, battery charger shall be provided in RMU

1

565000

565000

... More
Supply of 3 way RMU, 11KV ,630A, 21kA 3 Sec,SF6 Outdoor RMU-2 LBS.Extensible/Non-Extensible Two(2) Motor operated load break switches (LBS) with Manual operated earthing switches in SF6 SCADA Compatible and basic channel. Battery charger along woth batetried required for electrical opearations of RMU is in the scope of bidder .Each module shall consisit of VPIS,FPIin LBS Module(N-1) but not less than 1 nos per RMU. Suitable arranegment for mounting FRTU, modem or Ethernet Switch/LIU along with baterry, battery charger shall be provided in RMU

1

357000

357000

... More
Supply of 11KV, 3 phase, Indoor type, heat shrinkable end termination kit complete, for 11 KV XLPE cable of size 3 x 300 sq.mm including sockets/lugs/connectors etc. for connecting RMU for main section side of make Raychem.

4

35360

8840

... More
Supply of 11KV 3 phase outdoor terminating kit complete, for 11 KV XLPE cable of size 3 x 185 sq.mm including sockets/lugs/connectors etc. for connecting 11KV end of Distribution transformer of make Raychem.

1

10931

10931

... More
Supply of 11KV 3 phase indoor terminating kit complete, for 11 KV XLPE cable of size 3 x 185 sq.mm including sockets/lugs/connectors etc. for connecting RMU for main section side of make Raychem.

1

7873

7873

... More
Supply of RCC Cable route Markers (400 x 900 x 100 mm)

4

2112

528

... More
Supply of Warning tape for entire 11 KV route length.

0.35

5250

15000

... More
Supplying and filling in plinth under floors, trenches including watering ramming consolidating, dressing , complete a) Sand

34.56

74995

2170

... More
Supply of RCC protective covers of size 600mm long x 250mm width and 50 mm thick capable of bearing load of 135 Kg. And covered with earth/sand upto depth of 0.15 mts. Conforming to IS 1255-1967 at non-road crossing

1328

168656

127

... More
Supply of G.I. earthing pipe, 2500mm long, 40mm nominal dia, class B, perforated for RMU's The pit shall be filled with homogenous mixture of 20Kgs of Charcoal, 20Kgs of salt and sand /soil with Brick masonary Chambers The work includes excavation, backfilling & spreading of excavated surplace earth evenly at RMU's.

4

17712

4428

... More
Supply n of HDGI flat of size 25mm x 5mm for earthing of RMU's

20

2320

116

... More
Supply & providing of Centering and shuttering including struttings, propping etc. and removal of formwork for a) Foundations, footings, bases of columns and mass concrete for RMU's

7

3941

563

... More
Supply & providing of 12 mm cement plaster 1:4 ( 1 cement: 4 fine sand) for foundations of RMU's

1.4

205

147

... More
Supply and laying of RCC Hume Pipe 150mm dia with required no. of collars, for road crossing.

18

5706

317

... More
Supply and laying of GI pipe,150mm dia, Class B for bridge crossing.

5

8405

1681

... More
Supply & erection of Modem for Automatic meter reading

1

6000

6000

... More
Erection Cost

-

-

-

... More
Erection of 9 mts. long RCC poles .The poles should be as per drawing approved by CEE and conforming to IS standards as amended upto date. The Component used for pole shall conform to following IS amended upto date.

6

26448

4408

... More
Erection of 7.5 mts. long RCC poles .The poles should be as per drawing approved by CEE and conforming to IS standards as amended upto date. The Component used for pole shall conform to following IS amended upto date.

7

25823

3689

... More
Erection of Stay set complete for 9.0 mts RCC Pole.HDGI Stay Sets Complete Comprising of stay rod with plate, HDGI stay wire of size 7/10swg, Break insulator of 15KV/8KV,HDGI turn buckle with eye bolt, suitable HDGI stay clamps, HDGI nut bolts, . The Stay wire shall comply with the specific requirements of IS: 2141-1979, IS: 4826-1979 & IS: 6594-1974 or the latest versions thereof and also as per the specifications enclosed.

8

19728

2466

... More
Erection of Stay set complete for 7.5 mts RCC Pole.HDGI Stay Sets Complete Comprising of stay rod with plate, HDGI stay wire of size 7/10swg, Break insulator of 15KV/8KV,HDGI turn buckle with eye bolt, suitable HDGI stay clamps, HDGI nut bolts, . The Stay wire shall comply with the specific requirements of IS: 2141-1979, IS: 4826-1979 & IS: 6594-1974 or the latest versions thereof and also as per the specifications enclosed.

3

7212

2404

... More
Erection of HDGI nuts & bolts.G.I. Hexagonal head bolts and hexagonal nuts conforming to IS 1363 part 1 to 3 1992 as amended upto date.The bolts and nuts shall be hot dip galvanized as per IS: 2629-1985 as amended upto date, size-100 x 16

26

780

30

... More
Supply of Enamelled danger board of size 250mm x 200mm, 440Volts/11000 Volts/3300 Volts: The plate should be made from mild steel at least 1.6mm thick and vitreous enamelled white with letters, figures and convectional skull & bones in signal red colour on the front side. The rear side of the plate shall be enamelled. All letters should be centrally spaced. The corners of the plate should be rounded .

2

114

57

... More
Supply of Anticlimbing device(barbed wire).Hot dip galvanized steel barbed wire type 4 conforming to IS:278/1962 as amended upto date and galvanization conforming to IS:4826/1979as amended upto date. (Galvanising should be hot dippped Galvanised as per IS:2629/66, minimum Zinc coating of 1000gms/sq.mtr, 140 Microns DFT), suitable for high salinity coastal areas. Nominal diameter of line wire and point wire shall be 2.24mm each. Nominal distance between two barbs shall be 150mm. Tests as per IS shall be carried out at manufacturars work & test reports shall be furnished before supply of materials.

2

92

46

... More
Erection of HDGI Structure Materials. shall be hot dipped galvanized

274

12878

47

... More
Fixing of GI stay clamp LA for 9.0mts pole.shall be hot dipped galvanized generally conforming to IS - 2633/73

10

790

79

... More
Fixing of GI Xarm clamp SA for 9.0mts pole.shall be hot dipped galvanized generally conforming to IS - 2633/73

12

540

45

... More
Fixing of GI Xarm clamp LA for 9.0mts pole.shall be hot dipped galvanized generally conforming to IS - 2633/72

18

810

45

... More
Fixing of 11KV Disc insulator with metal parts.11 KV disc insulators ball and socket type, type ‘A’ porcelain brown glazed duly cemented at factory with MCI socket cap, forged steel ball pin and supplied with Phosphor bronze “W” split pin as per IS 731-1971 as amended upto date. Minimum failing load. 45 KN.Pin ball diameter 16 mm.3-bolted type hardware fitting suitable for 11KV ball and socket type disc insulators of 16mm pin, failing load of 45KN and suitable for ACSR WEASEL conductor

3

996

332

... More
Fixing of 11KV pin insulator with Gi pin.11 KV brown glazed porcelain pin insulator with minimum failing load of 5 KN and the Minimum creepage distance of 320 mm .Forged G. I. Pin conforming to IS 2486 part 1 & 2 as amended upto date

3

456

152

... More
Erection of 11 KV GOAB switch with 200 A.12 KV rated voltage GOAB switches tilting type, outdoor, manually operated, triple pole, single break, conforming to IS: 9921-Part1 to V as amended upto date and detailed specifications enclosed herewith. Each set shall comprise of six pedestal and three tilting post insulators. Insulator should be factory cemented by the manufactures of the insulators and have minimum 320mm creepage distance and AB switches contacts shall be of copper/copper alloy

1

3971

3971

... More
Erection of Earthing complete with 2.5mts long, 40mm GI earthing pipe, class B, 20kgs each of salt and charcoal, excvation, re-filling etc.Earthing pipe made of Hot Dip galvanized steel tube of heavy class, 40mm nominal bore conforming to IS 1239 Part 1 1990 as amended upto date and Hot Dip zinc coating shall conform to IS 4736-1968 as amended upto date

6

14664

2444

... More
Stringing of ACSR 'WEASEL' of size ( 6/1/2.59mm) for earthing and jumpering .Packing and marking of drum will be as per IS:Conductor length shall be 1500 mtr. with tolerance of +/- 5%

0.13

888

7110

... More
Erection, testing & comissioning of 11 KV HG fuse,200A, Horn gap type fuse I.TECHNICAL PARTICULARS: 1. Highest System voltage : 12 KV (R.M.S) 2. Impulse voltage withstand voltage : 75 KV (Peak) 3. One minute power frequency withstand voltage : 35 KV (R.M.S.) 4. Continuous current rating of the unit : 200 Amps

1

3368

3368

... More
Fixing of 9 KV, 5A Lightning Arrestor, pole mounted.9 KV, 5 KA nominal discharge current Metal Oxide gapless distribution class lightning arrestor conforming to IEC-60099-4 and IS 3070 Part 3 1993 as amended upto date suitable for 11 KV 50 HZ effectively earthed neutral system with necessary mounting arrangements and connector suitable to connect ACSR conductor upto overall diameter 12.30 mm.The marking of the Lightning Arrestors shall be as per IS

3

522

174

... More
Erection of MS Distribution box complete.M. S. distribution box MCCB of 400 Amps capacity Kit Kat Porcelain fuse carrier and base with extended terminals.

1

8795

8795

... More
Fixing of DTC metering unit

1

1072

1072

... More
Fixing CCMS Panel for street light 3 phase

1

1100

1100

... More
Providing of XLPE unarmoured cable 3 & half core 240 sq.mm.The unarmoured cable shall be of 1 core and of sizes as required i.e.120Sq.mm that shall be suitably terminated at both the ends with appropriate sizes of Aluminum lugs duly crimped using a crimping tool. Appropriate sizes of G.I / Brass nut / bolts / washers shall be used for firmly connecting the same to the MCCB’s/Transformer L.T. Bushings/Outgoing LT feeder

10

1760

176

... More
Providing of XLPE unarmoured cable 3 & half core 95 sq.mm.The unarmoured cable shall be of 1core and of sizes as required i.e.95 Sq.mm that shall be suitably terminated at both the ends with appropriate sizes of Aluminum lugs duly crimped using a crimping tool. Appropriate sizes of G.I / Brass nut / bolts / washers shall be used for firmly connecting the same to the MCCB’s/Transformer L.T. Bushings/Outgoing LT feeder

24

3576

149

... More
Erection, testing & comissioning of 100 KVA, Distribution transformer, 11KV/0.4KV with level-II losses, Alluminium Winding with Bimetallic Terminal connectors, Energy Efficiency Level-II as per IS:1180(Part-I):2014

1

11017

11017

... More
Providing of Aluminum crimping lugs shall conform to IS: 8309-1976 as amended upto date. Lugs shall be made of aluminium of grade 1E of IS 5082-1969 suitable for aluminium cables of following sizes: 1)240Sq.mm

6

528

88

... More
Providing of Aluminum crimping lugs shall conform to IS: 8309-1976 as amended upto date. Lugs shall be made of aluminium of grade 1E of IS 5082-1969 suitable for aluminium cables of following sizes: 1. 120 Sq.mm.

24

1560

65

... More
Providing of Aluminum crimping lugs shall conform to IS: 8309-1976 as amended upto date. Lugs shall be made of aluminium of grade 1E of IS 5082-1969 suitable for aluminium cables of following sizes: 1. 70Sq.mm.

20

1180

59

... More
Stringing of conductor-AA ANT, 2. 7/3.10 mm .nominal aluminum area 50mm^2 (190 amps max. at 40 deg.C)

1.41

9353

6634

... More
Stringing of conductor -AA GNAT,1. 7/2.21 mm,nominal aluminum area 25mm^2 (80 amps max. at 40 deg.C)

1.26

7790

6183

... More
Fixing of Cross Arm Channel 4Pin .The cross arms shall be made of M.S. channel of ISMC-75 vide table 2 of IS: 8081 1964 . The cross arms shall be without any joints. The cross arms shall be hot dipped galvanized generally conforming to IS - 2633/72. The length of the 4pin cross arm shall be 1110mm with 4 holes of 22 dia each on each flange section. In addition 2 holes of size 18mm x 40mm slotted holes shall be provided on the cross arm for clamping arrangement to the pole. The length of the 4pin side cross arm shall be 1410mm with 4 holes of 22 dia each on each flange section. In addition 2 holes of size 18mm x 40mm slotted holes shall be provided on the cross arm 40 mm from the left edge of the X-arm for clamping arrangement to the pole & two holes of size 17mm dia at 355mm & 660mm from the slotted hole for arrangement to fix angle support. The angle support shall be of ISA 50x50x6mm G.I. with 17 mm dia holes at the two ends. The other end of the angle shall be clamps utilizing suitable G. I. stay clamps of length 312mm end to end

17

4437

261

... More
Fixing of Cross Arm Channel 2Pin .The cross arms shall be made of M.S. channel of ISMC-75 vide table 2 of IS: 8081 1964 . The cross arms shall be without any joints. The cross arms shall be hot dipped galvanized generally conforming to IS - 2633/72. The length of the 4pin cross arm shall be 1110mm with 4 holes of 22 dia each on each flange section. In addition 2 holes of size 18mm x 40mm slotted holes shall be provided on the cross arm for clamping arrangement to the pole. The length of the 4pin side cross arm shall be 1410mm with 4 holes of 22 dia each on each flange section. In addition 2 holes of size 18mm x 40mm slotted holes shall be provided on the cross arm 40 mm from the left edge of the X-arm for clamping arrangement to the pole & two holes of size 17mm dia at 355mm & 660mm from the slotted hole for arrangement to fix angle support. The angle support shall be of ISA 50x50x6mm G.I. with 17 mm dia holes at the two ends. The other end of the angle shall be clamps utilizing suitable G. I. stay clamps of length 312mm end to end

20

4640

232

... More
Erection of GI Xarm clamp SA for 7.5mts pole.shall be hot dipped galvanized generally conforming to IS - 2633/73

14

448

32

... More
Erection of GI Xarm clamp LA for 7.5mts pole.shall be hot dipped galvanized generally conforming to IS - 2633/72

17

544

32

... More
Fixing of LT pin insulator with GI pin

48

8304

173

... More
Fixing of Insulator -(LT) Shackle .L.T. brown glazed shackle insulators of size 100mm x 115mm conforming to fig.No.4 and type 2 of IS: 1445/77 as amended upto date. Minimum failing load shall be 16kN. Insulators shall have marking and packing as prescribed in IS

80

16640

208

... More
Fixing of FRP Fencing complete with Gate around every distribution sub-station containing RMU, one distribution transformer and one LV switchboard including danger plate (Size  4Mx3Mx2M) with Concreting for FRP Fencing supports with plinth (0.3x0.3x0.5) Cu.m. x 12 nos. Each ratio 1:3:6

1

25000

25000

... More
Removing of RCC pole 7.5 mts long

1

1844

1844.5

... More
Removing of 4 PIN 'X' arm of 75x40 Channel

2

261

130.5

... More
Removing of 2 PIN 'X' arm of 75x40 Channel

1

116

116

... More
Removing of LT shackle insulator with metal parts

6

624

104

... More
Removing of LT pin insulator with G.I Pin

3

259

86.5

... More
laying of 11KV, 3 core, 300 sq.mm. aluminium, XLPE insulated, flat wire armoured, 11 KV (Earthed) Cable

745

254790

342

... More
laying of 11KV, 3 core 185sq.mm aluminium, XLPE insulated, flat wire armoured, 11 KV (Earthed) Cable

32

8416

263

... More
Erection , testing & comisioning of 3 WAY RMU ,11KV, 630 Amps,21 kA, 3 sec, SF6 Outdoor RMU- 2 LBS+ 1 CB Extension/Non-Extendable Two(2) Motor operated load break switches (LBS) with Manual operated earthing switches in SF6 and One (1) vaccum circuir breaker with electrical closing and tripping along with disonnector and earthing switches SCADA Compatible and basic channel. Battery charger along woth batetried required for electrical opearations of RMU is in the scope of bidder .Each module shall consisit of VPIS,FPIin LBS Module(N-1) but not less than 1 nos per RMU. Suitable arranegment for mounting FRTU, modem or Ethernet Switch/LIU along with baterry, battery charger shall be provided in RMU

1

9720

9720

... More
Erection, testing & comissioning of 3 way RMU, 11KV ,630A, 21kA 3 Sec,SF6 Outdoor RMU-2 LBS.Extensible/Non-Extensible Two(2) Motor operated load break switches (LBS) with Manual operated earthing switches in SF6 SCADA Compatible and basic channel. Battery charger along woth batetried required for electrical opearations of RMU is in the scope of bidder .Each module shall consisit of VPIS,FPIin LBS Module(N-1) but not less than 1 nos per RMU. Suitable arranegment for mounting FRTU, modem or Ethernet Switch/LIU along with baterry, battery charger shall be provided in RMU

1

9720

9720

... More
Erection of 11KV, 3 phase, Indoor type, heat shrinkable end termination kit complete, for 11 KV XLPE cable of size 3 x 300 sq.mm including sockets/lugs/connectors etc. for connecting RMU for main section side of make Raychem.

4

10192

2548

... More
Erection of 11KV 3 phase outdoor terminating kit complete, for 11 KV XLPE cable of size 3 x 185 sq.mm including sockets/lugs/connectors etc. for connecting 11KV end of Distribution transformer of make Raychem.

1

2648

2648

... More
Erection of 11KV 3 phase indoor terminating kit complete, for 11 KV XLPE cable of size 3 x 185 sq.mm including sockets/lugs/connectors etc. for connecting RMU for main section side of make Raychem.

1

2548

2548

... More
Erection of RCC Cable route Markers (400 x 900 x 100 mm)

4

1024

256

... More
Excavation in any type of soil including hard laterite soil by mechanical means( hydraulic excavator)/manual means for laying of HT/ LT cables of various sizes including excavation for equipment foundations i.e for RMU's including getting out the excavated soil and disposal of surplus excavated soil.

236.6

110728

468

... More
Refilling of excavated soil in the foundations, trenches etc. with available excavated earth in layers not exceeding 20 cm depth, cosolidating each layer by ramming and watering lead upto 50 M and all lifts and disposal of surplus earth in cable trenches and foundations of equipments.

130.12

15614

120

... More
Laying of RCC protective covers of size 600mm long x 250mm width and 50 mm thick capable of bearing load of 135 Kg. And covered with earth/sand upto depth of 0.15 mts. Conforming to IS 1255-1967 at non-road crossing

1328

111552

84

... More
S.E.T.C of G.I. earthing pipe, 2500mm long, 40mm nominal dia, class B, perforated for RMU's The pit shall be filled with homogenous mixture of 20Kgs of Charcoal, 20Kgs of salt and sand /soil with Brick masonary Chambers The work includes excavation, backfilling & spreading of excavated surplace earth evenly at RMU's.

4

10660

2665

... More
Erection of HDGI flat of size 25mm x 5mm for earthing of RMU's

20

960

48

... More
Laying of RCC Hume Pipe 150mm dia with required no. of collars, for road crossing.

18

2718

151

... More
Laying of GI pipe,150mm dia, Class B for bridge crossing.

5

910

182

... More
Carrying out detailed physical survey of the area including detailed GPS survey which includes indicating and marking location of other utilities if any

0.45

6750

15000



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.