Electricity Department Tender

View complete overview of Goa Electricity Department Tender

Electricity Department Tender

Works
Electrical and Electronics
Eprocure
Opening Date28 Mar 2025
Closing Soon9 Apr 2025
Tender Amount₹ 15,56,068 
Notes
Download

Costs

  • EMD

    ₹ 31,121
  • Document Cost

    ₹ 500
  • Tender Fee

    ₹ 3,112

Summary

1)work Of Erection Of New 100kva Dtc At Saliswaddo Parra In Order To Solve Low Voltage Problem Faced By The Locals Of Saliswaddo And Gamawaddo, Parra Work Of Erection Of New 200kva Dtc At Sanqwadi Arpora In Order To Solve Low Voltage Problem Faced

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
XLPE Outdoor heat shrinkable Termination Kit suitable for 3 core x 95 Sq.mm,Cable

1

10152

10152

... More
XLPE indoor heat shrinkable Termination Kit suitable for 3 core x 95 Sq.mm,Cable

1

6731

6731

... More
Providing and laying in position cement concrete 1:2:4 ( 1 cement :2 coarse sand :4 graded granitic or basaltic stone aggregate 40mm nominal size) excluding cost of centering,shuttering and finishing (for plinths of 200KVA transformer-2.24cumt, RMU-2 cumt)

4.24

6635

28132.4

... More
Centering & shuttering including struttings, propping etc & remonal of formwork

14.25

407

5799.75

... More
12mm cement plaster 1:4 (1 - cement: 4 - fine sand) for foundations.

11.82

223

2635.86

... More
M.S.Distribution box with MCCB 400 amps and Kitkat fuses for 200KVA Distribution T/C

1

63140

63140

... More
Distribution Transformer Metering Unit.

1

25688

25688

... More
CAMR Modem for metering

1

6000

6000

... More
Earthing complete with 2.5mts long ,40mm Gl earthing pipe, classB, 20kgs each of salt and charcoal,excvation, re-filling etc.

8

2730

21840

... More
GI flats 25x5mm for earthing

80

116

9280

... More
Earthwork excavation for HT Cable in foundations trenches ( not exceeding 1.5mts in width or 10mm² on plan) including opening of roads, chamber/pavements & soiling, ramming, levelling of bottoms, making free from stones including removing out the excavated soil/material as directed within a lead os 40mts in laterite rock soil (1.1X 0.6 X200)

132

-

-

... More
Back filling up for HT Cable of available excavated earth (excluding rock/stones) in trenches, plinth, sides, foundations etc. in layer not exceeding 0.2 mtrs, depth consolidation each deposited layer by ramming & watering (0.9 x 0.6 x 200 mtr)

108

-

-

... More
Disposal of surplus excavated soil/material at a distance of 3000 mtrs (0.2 x 0.6 x 200mtr) for HT Cable

24

-

-

... More
Supply & Laying of sand.(0.2 x 0.6 x 200 mtr)for HT Cable

24

2170

52080

... More
Bricks 1st class wire cut for HT Cable (10 bricks per meter)

2000

9

19000

... More
Cement protective covers of size 600mm length x 250mm width x 37mm thick as a protective cover for underground HT Cable

333

127

42291

... More
Cable route Markers.for HT Cable

5

528

2640

... More
FRP Fencing complete with Gate as per specification for Distribution Transformer (Size 4Mx3Mx2M) with Concreting for FRP Fencing supports with plinth(0.3x0.3x0.5) Cu.m x 12 nos. Each ratio 1:3:6

1

76667

76667

... More
11 KV Enamelled danger boards CEE/E-490

4

248

992

... More
XLPE cable armoured 3.5 core 185 sq.mm 1.1 KV grade.

45

1355

60975

... More
Stay wire 7/10SWG

3.74

141

527.34

... More
AAC conductor 'ANT'

0.1

60500

6050

... More
AAC conductor 'GNAT'

0.1

31000

3100

... More
Removing and Restringing AAC conductor 'ANT'

0.96

-

-

... More
Removing & Restringing AAC 'GNAT' Conductor 7/2.21

0.96

-

-

... More
COST OF ERECTION

-

-

-

... More
XLPE 11KV straight through joint 3 core 185 Sq.mm suitable for 185 sq.mm, 11KV XPLE cable.

1

3450

3450

... More
Supply & laying of XLPE 11KV 3core 185 Sq.mm Armoured Cable ( 120x 2 )

240

263

63120

... More
Supply,erection of 11 KV, 630 Amps, Outdoor SF6 Ring main unit with two load break Switches and one Circuit breaker suitable for usage on 11 KV 50Hz.,350 MVA effectively earthed system.

1

9720

9720

... More
Supply & laying of XLPE 11KV 3core x 95 Sq.mm Armoured Cable ( New RMU to HT side of the Transformer)

15

199

2985

... More
XLPE indoor heat shrinkable Termination Kit suitable for 185 Sq.mm, 1 KV XLPE

3

2548

7644

... More
XLPE Outdoor heat shrinkable Termination Kit suitable for 3 core x 95 Sq.mm,Cable

1

2648

2648

... More
XLPE indoor heat shrinkable Termination Kit suitable for 3 core x 95 Sq.mm,Cable

1

2538

2538

... More
200 KVA 11KV /0.4KV Distribution Transformer (Level II losses)

1

15638

15638

... More
Supply and laying of unarmoured 1core 300 sqmm XLPE power cable to be laid from transformer to Distribution box ( 1run per phase ) (8 mtrs x 4 run)

32

218

6976

... More
M.S.Distribution box with MCCB 400 amps and Kitkat fuses for 200KVA Distribution T/C

1

8795

8795

... More
Distribution Transformer Metering Unit.

1

1072

1072

... More
Earthing complete with 2.5mts long ,40mm Gl earthing pipe, classB, 20kgs each of salt and charcoal,excvation, re-filling etc.

8

2444

19552

... More
GI flats 25x5mm for earthing

80

48

3840

... More
Earthwork excavation for HT Cable in foundations trenches ( not exceeding 1.5mts in width or 10mm² on plan) including opening of roads, chamber/pavements & soiling, ramming, levelling of bottoms, making free from stones including removing out the excavated soil/material as directed within a lead os 40mts in laterite rock soil (1.1X 0.6 X200)

132

468

61776

... More
Back filling up for HT Cable of available excavated earth (excluding rock/stones) in trenches, plinth, sides, foundations etc. in layer not exceeding 0.2 mtrs, depth consolidation each deposited layer by ramming & watering (0.9 x 0.6 x 200 mtr)

108

120

12960

... More
Disposal of surplus excavated soil/material at a distance of 3000 mtrs (0.2 x 0.6 x 200mtr) for HT Cable

24

125

3019.68

... More
Cement protective covers of size 600mm length x 250mm width x 37mm thick as a protective cover for underground HT Cable

333

84

27972

... More
Cable route Markers.for HT Cable

5

256

1280

... More
FRP Fencing complete with Gate as per specification for Distribution Transformer (Size 4Mx3Mx2M) with Concreting for FRP Fencing supports with plinth(0.3x0.3x0.5) Cu.m x 12 nos. Each ratio 1:3:6

1

35000

35000

... More
11 KV Enamelled danger boards CEE/E-490

4

57

228

... More
XLPE cable armoured 3.5 core 185 sq.mm 1.1 KV grade.

45

228

10260

... More
RCC poles 9.00 mtr

1

5900

5900

... More
HDGI 4 pin 'X' arm of 75 x 40 Channel

1

261

261

... More
HDGI 2 pin 'X' arm of 75 x 40 Channel

1

232

232

... More
HDGI 'X' arm clamps for RCC Pole 9.00 mtr L.A.

2

45

90

... More
Stay wire 7/10SWG

3.74

62

231.88

... More
G.I. Stay rod & plate LT/11KV line

1

1779

1779

... More
G.I. Turn Buckle with eye bolt 11 KV

1

267

267

... More
Break insulators 8 KV (44KN)

1

97

97

... More
HDGI stay clamps for RCC Pole 9 Mts

1

79

79

... More
LT shackle Insulator

60

104

6240

... More
Metal parts for L.T. Shackle insulators

60

104

6240

... More
G.I. Nuts & Bolts

2

30

60

... More
AAC conductor 'ANT'

0.1

10300

1030

... More
AAC conductor 'GNAT'

0.1

9100

910

... More
Removing and Restringing AAC conductor 'ANT'

0.96

15450

14832

... More
Removing & Restringing AAC 'GNAT' Conductor 7/2.21

0.96

13650

13104

... More
COST OF MATERIAL (Sub Estimate 1)

-

-

-

... More
Pole Numbering

6

104

625.98

... More
Supply and Erection of HDG.I. stay wire 7/10 SWG conforming to IS-2141/1979 grade- I, IS:4826-1979 & IS:6594-1974 or latest version thereof with tensile grade 4 & having minimum tensile strenght of 700N/mm2 conforming to IS:2141 or the latest version thereof

20.36

141

2870.76

... More
Supply and Erection PVC insulated single core cable 90 mm2

180

128

23040

... More
Supply and Erection PVC insulated single core cable 50 mm2 for D.P. earthing

50

135

6750

... More
Supply and Erection of DTC Metering Unit

1

25688

25688

... More
Modem for Automatic Meter Reading

1

6000

6000

... More
Earthing complete comprises of H.D.G.I. Pipe of class B length 2.5 mts , 40mm nominal bore(outside diameter 48.8mm maximum and 47.9mm minimum ,thickness4.0mm and mass of tube plain end 4.37kg/m) conforming to IS1239 Part 1 1990 asamended upto date and hot dip zinc coating shall conform to IS 4736 as ACSR'Weasel' Conductor( quantity as required) , pit filled with homogeneous layer of20 kgs of charcoal, sand and salt as per the drawing No. CEE/E-829

8

2730

21840

... More
Supply and Erection of MS Distribution box as per drg No. CEE/E-689 Revision No. 2 along with MCCB 400 A, Bus bar made out of Aluminium strips 40 x 10 mm, Other accessories & 200 Amps, Porcelain KitKat Fuse Carrier & Base with extended terminals shall be as per drawing No.CEE/E/543-Rev 4 (Set of 3) for 4 feeder arrangement with 1 no of moulded case circuit breaker (MCCB) of 400A, 415V, AC 50 Hz for 100 KVA Distribution Transformer centre

1

63140

63140

... More
Supply and Erection Enamelled Danger board 400V of size 250mm x 200 mm as per the drawing No. CEE/E-490.

2

248

496

... More
Supply and Erection Anticlimbing deviceas per the drawing No. CEE/E-478.

2

962

1924

... More
Supply, transportation to site and laying of 1.1 KV 3.5 core XLPE armoured 185 sq.mm cable

36

1355

48780

... More
FRP Fencing Complete with Gate as per specifcation for Distribution Transformer (Size 4MX3MX2M) with Concreting for FRP Fencing supports with plinth (03x0.3x0.5) Cu.m. x 12 nos. Each ratio 1:3:6

1

76667

76667

... More
Supply and Stringing of AAC 'ANT' Conductor, hard drawn stranded aluminium conductor & conforming to IS:398(Pt-I/76) with ammendment no. 1,2 & 3 & of size 7/3.10mm aluminium, (nominal aluminium area 50mm)

0.2

60500

12100

... More
Supply and Stringing of AAC 'GNAT' Conductor, hard drawn stranded aluminium conductor & conforming to IS:398(Pt-I/76) with ammendment no. 1,2 & 3 & of size 7/2.21mm aluminium, (nominal aluminium area 25mm2)

0.06

31000

1860

... More
Supply and Stringing of Hard drawn stranded aluminium conductor galvanized steel reinforced & conforming to IS:398(Pt-II/96) with amendment no. 1 & 3 & of size 6/2.59 mm aluminium, 1/2.59 mm steel wire "WEASEL"

0.1

40100

4010

... More
Removing and Restringing AAC conductor 'ANT'

1.8

-

-

... More
Removing and Restringing AAC conductor 'GNAT'

1.89

-

-

... More
Removing RCC poles 7.5 mtr

2

-

-

... More
Removing HDGI 2 pin 'X' arm of 75 x 40 Channel

2

-

-

... More
Removing HDGI 4 pin 'X' arm of 75 x 40 Channel

2

-

-

... More
Removing L.T. Pin Insulators

37

-

-

... More
Removing G.I. Pin for L.T.Pin Insulators

37

-

-

... More
Earthwork in excavation by mechanical means (hydraulic excavator)/manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sq.m on plan) including disposal of excavated earth lead upto 50 m and lift upto 1.5m disposed earth to be leveled and neatly dressed including providing barricading, danger lighting guarding as directed in :Dimensions for excavation are 0.6X1.1X+15

7.2

-

-

... More
Refilling the pipeline/foundation trenches plinth side,foundation etc. with available excavated earth in layers not exceeding 20 cm depth consolidating each layer ramming and watering lead upto 50 M and all lifts and disposal of surplus earth as directed by Engineer in Charge(0.9X0.6X450)

5.66

-

-

... More
Disposal of surplus earth

1.54

-

-

... More
Supplying and filling in plinth under floors, trenches including watering ramming consolidating, dressing, complete. (Sand for cushioning of HT underground cables).(0.6X0.2X15)

1.2

2170

2604

... More
Bricks class design 75 kg/cm2 (1st class wire cut)

75

9

712.5

... More
Providing and laying in position cement concrete 1:2:4 (1 cement : 2 coarse sand: 4 graded granitic or basaltic stone aggregate 40 m nominal size) for foundations of RMU(0.5 cu mt/ Per RMU)

0.5

6635

3317.5

... More
Centering and shuttering including struttings, propping etc and removal of formwork for : Foundations, footings, bases for columns and mass concrete for RMU (3.50sq.mt/RMU).

3.5

407

1424.5

... More
GI Pipe 100 mm , class B

5

811

4055

... More
RCC Protective covers of size 600mm length x 250mm width and 50 mm thick capable of bearing load of 135 Kg and covered with earth/sand upto depth of 0.15mts.Confirming to IS 1255-1967 at non-road crossing.

25

127

3175

... More
RCC Cable route Markers.

1

528

528

... More
Warning tape.

0.02

15000

225

... More
H.S.11 KV Termination kit indoor 240/300 XLPE 3 Core

2

8840

17680

... More
H.S.11 KV Termination kit indoor 50 to 95 XLPE 3 Core

1

6731

6731

... More
H.S.11KV Termination kit outdoor 50 to 95 XLPE 3 Core

1

10152

10152

... More
H.S. 11KV straight through joint 3 Core 240 to 400 Sq.mm

1

29559

29559

... More
G.I. Flat 25 x 5 mm

25

116

2900

... More
COST OF ERECTION

-

-

-

... More
RCC poles 11.00 mtr

2

9800

19600

... More
Erection of RCC pole 9 mtr

3

5900

17700

... More
Erection of RCC pole 7.5 mtr

1

5200

5200

... More
Supply and Erection HDGI 2 pin 'X' arm of 75 x 40 Channel as per the drawing No.CEE/E/704 as per annexure confirming to IS- 2633/72 or the latest version thereof

7

232

1624

... More
Supply and Erection HDGI 4 pin 'X' arm of 75 x 40 Channel as per the drawing No.CEE/E/705 as per annexure confirming to IS- 2633/72 or the latest version thereof.

9

261

2349

... More
100 KVA 11kv/.4kv Distribution Transformers level II losses, Alluminium Winding, with Bimetallic Terminal Connectors, Energy Efficiency Level-II as per IS: 1180 (Part-I): 2014

1

11017

11017

... More
HDGI X arm clamps for RCC Pole 11.00 mtr L.A

5

65

325

... More
Supply and Erection HDGI 'X' arm clamps for RCC Pole 9.00 mtr L.A. as per the drawing No.CEE/E-524 as per annexure confirming to IS- 2633/72 or the latest version thereof

8

45

360

... More
Supply and Erection HDGI 'X' arm clamps for RCC Pole 7.5 mtr L.A. as per the drawing No.CEE/E-524 as per annexure confirming to IS- 2633/72 or the latest version thereof

3

32

96

... More
HDGI stay clamps for RCC Pole 11.00Mts L.A.

2

98

196

... More
Supply and Erection HDGI stay clamps for RCC Pole 9 mtr L.A. as per the drawing No.CEE/E-524 as per annexure confirming to IS- 2633/72 or the latest version thereof

3

79

237

... More
Supply and Erection of HDG.I. stay wire 7/10 SWG conforming to IS-2141/1979 grade- I, IS:4826-1979 & IS:6594-1974 or latest version thereof with tensile grade 4 & having minimum tensile strenght of 700N/mm2 conforming to IS:2141 or the latest version thereof

20.36

62

1262.32

... More
Supply and Erection of H.D.G.I. stay rod of 1200mm long and 16mm dia with an eye band of internal dia 40mm at one end and threaded up to length of 200mm at the other end galvanised. H.D.G.I.stay plate of 450x450x8mm size with a hole drilled at the centre to suit 16mm dia GI rod galvanised.as per the drawing No. CEE/E-465

5

1779

8895

... More
Supply and Erection G.I. Turn Buckle with eye bolt 11 KV as per the drawing No. CEE/E-466

5

267

1335

... More
Supply and Erection of Break insulators 8 KV (44KN) as per the drawing No. CEE/E-425 as per annexure confirming to the IS:5300-1969 or the latest version thereof

5

97

485

... More
G.I. Nuts & Bolts as per annexure confirming to the IS- 2633/72 or the latest version thereof

14.84

30

445.2

... More
Supply and Erection PVC insulated single core cable 90 mm2

180

91

16380

... More
Supply and Erection PVC insulated single core cable 50 mm2 for D.P. earthing

50

56

2800

... More
Supply and Erection 11 KV rated voltange GOAB switches tilting type, outdoor, manually operated, triple pole, single break, conforming toIS-9921 (Part-I to IV) [ 1981 - 85] as amended up to date and detailed specification eclosed herewith. Each set shall comprise of six pedestal and three tilting post insulators. Insulator should be factory cemented by the manufacturer of the insulators and have minimum 320 mm creepage distance and AB switchs contacts shall be of copper/ copper alloy. The AB switch shall be of following current rating: 200 A

1

3971

3971

... More
Supply and Erection of 9 KV, 5 KA nominal discharge current metal oxide gapless distribution class Lightning arrestor conforming to IEC-600994-4 and IS: 3070 part 3 1993 as amended upto date suitable for 11 KV 50 HZ effectively earthed neutral system with necessary mounting arragements and connector suitable to connect ASCR conductor upto overall diameter 12.30 mm

3

174

522

... More
11 KV , 200 A Horn gap fuse unit (Set of three) shall be as per drg No. CEE/E-786 as per annexure confirming toI.S. 2062,IS: 1367,IS: 4218,IS: 1363,IS-209 1979 or the latest version thereof

1

3368

3368

... More
Supply and Erection of DTC Metering Unit

1

1072

1072

... More
Earthing complete comprises of H.D.G.I. Pipe of class B length 2.5 mts , 40mm nominal bore(outside diameter 48.8mm maximum and 47.9mm minimum ,thickness4.0mm and mass of tube plain end 4.37kg/m) conforming to IS1239 Part 1 1990 asamended upto date and hot dip zinc coating shall conform to IS 4736 as ACSR'Weasel' Conductor( quantity as required) , pit filled with homogeneous layer of20 kgs of charcoal, sand and salt as per the drawing No. CEE/E-829

8

2444

19552

... More
Supply and Erection of MS Distribution box as per drg No. CEE/E-689 Revision No. 2 along with MCCB 400 A, Bus bar made out of Aluminium strips 40 x 10 mm, Other accessories & 200 Amps, Porcelain KitKat Fuse Carrier & Base with extended terminals shall be as per drawing No.CEE/E/543-Rev 4 (Set of 3) for 4 feeder arrangement with 1 no of moulded case circuit breaker (MCCB) of 400A, 415V, AC 50 Hz for 100 KVA Distribution Transformer centre

1

8795

8795

... More
Supply and Erection Enamelled Danger board 400V of size 250mm x 200 mm as per the drawing No. CEE/E-490.

2

57

114

... More
Supply and Erection Anticlimbing deviceas per the drawing No. CEE/E-478.

2

175

350

... More
Supply and Erection XLPE Single Core unarmoured 300 sq mm,cross linked polyethelene insulated, PVC shealthed 1 core 300 sqmm cable 1.1.KV gradesuitable for 3 phase earthed system and conforming to IS: 7098 (Part-I)/1988 as amended upto date.

48

218

10464

... More
Supply, transportation to site and laying of 1.1 KV 3.5 core XLPE armoured 185 sq.mm cable

36

228

8208

... More
FRP Fencing Complete with Gate as per specifcation for Distribution Transformer (Size 4MX3MX2M) with Concreting for FRP Fencing supports with plinth (03x0.3x0.5) Cu.m. x 12 nos. Each ratio 1:3:6

1

35000

35000

... More
Supply and Erection of Aluminium crimping Lugs shall conform to IS: 8309-1976 as amended upto date. Lugs shall be made of aluminium of grade IE of IS: 5082/1969 suitable for aluminium cable of 300 sq.mm

8

101

808

... More
Supply and Erection of Aluminium crimping Lugs shall conform to IS: 8309-1976 as amended upto date. Lugs shall be made of aluminium of grade IE of IS: 5082/1969 suitable for aluminium cable of 185 sq.mm

12

95

1140

... More
Supply and Erection of LT brown glazed shackle Insulator of size 100 mm x 115 mm conforming to fig No. 4 and type 2 fo IS: 1445/77 as amended upto date. Minimum failing load shall be 16 KN with GI hardware suitable for LT shackle insulator of size 100 x 115 mm conforming to type 2 fig 4 of IS: 1445/77 as amended upto date as per the drawing No.EE/X/TRN/DRG1/2.

130

104

13520

... More
Supply and Erection Metal parts for L.T. Shackle insulators or the Strap type fittings shall consists of a pair of H.D.G.I. straps, 2nos. H.D.G.I. bolts with hexagonal head & nuts, 2 nos. H.D.G.I. spring washers, & helically formed conductor dead-end fittings made of aluminium alloy or aluminium-clad steel conforming to the relevant IS specifications as per the drawing No.EE/X/TRN/DRG1/2.

130

104

13520

... More
Supply and Stringing of AAC 'ANT' Conductor, hard drawn stranded aluminium conductor & conforming to IS:398(Pt-I/76) with ammendment no. 1,2 & 3 & of size 7/3.10mm aluminium, (nominal aluminium area 50mm)

0.2

10300

2060

... More
Supply and Stringing of AAC 'GNAT' Conductor, hard drawn stranded aluminium conductor & conforming to IS:398(Pt-I/76) with ammendment no. 1,2 & 3 & of size 7/2.21mm aluminium, (nominal aluminium area 25mm2)

0.06

9100

546

... More
Supply and Stringing of Hard drawn stranded aluminium conductor galvanized steel reinforced & conforming to IS:398(Pt-II/96) with amendment no. 1 & 3 & of size 6/2.59 mm aluminium, 1/2.59 mm steel wire "WEASEL"

0.1

11000

1100

... More
Removing and Restringing AAC conductor 'ANT'

1.8

15450

27810

... More
Removing and Restringing AAC conductor 'GNAT'

1.89

13650

25798.5

... More
Removing RCC poles 7.5 mtr

2

2600

5200

... More
Removing HDGI 2 pin 'X' arm of 75 x 40 Channel

2

116

232

... More
Removing HDGI 4 pin 'X' arm of 75 x 40 Channel

2

130

261

... More
Removing L.T. Pin Insulators

37

49

1831.5

... More
Removing G.I. Pin for L.T.Pin Insulators

37

37

1369

... More
Earthwork in excavation by mechanical means (hydraulic excavator)/manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sq.m on plan) including disposal of excavated earth lead upto 50 m and lift upto 1.5m disposed earth to be leveled and neatly dressed including providing barricading, danger lighting guarding as directed in :Dimensions for excavation are 0.6X1.1X+15

7.2

468

3369.6

... More
Refilling the pipeline/foundation trenches plinth side,foundation etc. with available excavated earth in layers not exceeding 20 cm depth consolidating each layer ramming and watering lead upto 50 M and all lifts and disposal of surplus earth as directed by Engineer in Charge(0.9X0.6X450)

5.66

120

679.2

... More
Disposal of surplus earth

1.54

125

193.76

... More
Bricks class design 75 kg/cm2 (1st class wire cut)

75

-

-

... More
GI Pipe 100 mm , class B

5

92

460

... More
RCC Protective covers of size 600mm length x 250mm width and 50 mm thick capable of bearing load of 135 Kg and covered with earth/sand upto depth of 0.15mts.Confirming to IS 1255-1967 at non-road crossing.

25

84

2100

... More
RCC Cable route Markers.

1

256

256

... More
3 WAY RMU,11 KV,630 A,21 k A 3Sec, SF6 Oudoor RMU-2LBS+1CB Extensible/Non-Extensible Two (2) Motor operated load break switches (LBSs) with Electrical closing and tripping along with disconnector and earthing switchs in SF6 and One (1 ) vacuum circuit breaker with Electrical closing and tripping along with disconnector and earthing switches SCADA Compatible and base channel. Battery Charger along with batteries required for Electrical operations of RMU is in the scope of the Bidder. Each module shall consists of VPIS,FPI in LBS Module (N-1) but not less than 1 no's per RMU. Suitable arrangement for mounting FRTU, modem or Ethernet Switch/LIU along with battery,battery charger shall be provided in RMU.

1

9720

9720

... More
Supply, storage transportation to work site, laying termination, testing and commissioning of XLPE cable of voltage 11 KV 3 core 300 Sq.mm excluding cable end termination.

50

342

17100

... More
Supply, storage transportation to work site, laying termination, testing and commissioning of XLPE cable of voltage 11 KV 3 core 95 Sq.mm excluding cable end termination.

25

199

4975

... More
H.S.11 KV Termination kit indoor 240/300 XLPE 3 Core

2

2548

5096

... More
H.S.11 KV Termination kit indoor 50 to 95 XLPE 3 Core

1

2538

2538

... More
H.S.11KV Termination kit outdoor 50 to 95 XLPE 3 Core

1

2648

2648

... More
H.S. 11KV straight through joint 3 Core 240 to 400 Sq.mm

1

3713

3713

... More
G.I. Flat 25 x 5 mm

25

48

1200



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements

Past Bidders
This list is curated from the bidders of the similar tenders in the past

Unlock the Tender details for free
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.