Electricity Department Tender

View complete overview of Goa Electricity Department Tender

Electricity Department Tender

Works
Civil And Construction
Eprocure
Opening Date23 Dec 2023
Closing Date9 Jan 2024
Tender Amount₹ 59,15,510 
Notes
Download

Costs

  • EMD

    ₹ 1,18,310
  • Document Cost

    ₹ 1,000
  • Tender Fee

    ₹ 6,000

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
Supply, Erection, Testing and Comissioning of Outdoor type, heat shrinkable, three phase, end termination kit complete, for 11KV XLPE cable of size 3 x 95sq.mm .

2

20304

10152

... More
Supply, Erection, Testing and Comissioning of Indoor type, heat shrinkable, three phase, end termination kit complete, for 11KV XLPE cable of size 3 x 95sq.mm.

2

13462

6731

... More
Supply, Erection, Testing and Comissioning of Indoor type, heat shrinkable, three phase, end termination kit complete, for 11KV XLPE cable of size 3 x 300sq.mm.

7

61880

8840

... More
Supply, Erection, Testing and Comissioning of Outdoor type, heat shrinkable, three phase, end termination kit complete, for 11KV XLPE cable of size 3 x 300sq.mm .

2

23334

11667

... More
3 WAY RMU, 11KV, 630A, 21 kA 3Sec, SF6 Outdoor RMU – 2LBS + 1CB Extensible/Non-Extensible Two (2) Motor operated load break switches (LBSs) with Manual operated earthing switches in SF6 and One (1) vacuum circuit breaker with Electrical closing and tripping along with disconnector and earthing switches SCADA Compatible and base channel. Battery charger along with batteries required for Electrical operations of RMU is in the scope of the Bidder. Each module shall consist of VPIS, FPI in LBS Module (N-1) but not less than 1 no’s per RMU. Suitable arrangement for mounting FRTU, modem or Ethernet Switch/LIU along with battery, battery charger shall be provided in RMU.

2

1250000

625000

... More
3 WAY RMU, 11KV, 630A, 21 kA 3Sec, SF6 Outdoor RMU – 3LBS Extensible/Non Extensible Three (3) Motor operated load break switches (LBSs) with Manual operated earthing switches in SF6 SCADA Compatible and base channel. Battery charger along with batteries required for Electrical operations of RMU is in the scope of the Bidder. Each module shall consist of VPIS, FPI in LBS Module (N-1) but not less than 1 no’s per RMU. Suitable arrangement for mounting FRTU , modem or Ethernet Switch/LIU along with battery, battery charger shall be provided in RMU.

1

615000

615000

... More
RCC Cable route marker

5

2640

528

... More
Supply, Laying of Warning Tapes (for entire route length) as per technical specification and drawing.

0.41

6150

15000

... More
Design, Supply & Erection of RCC Hume pipes for road crossings, nullah crossings, small river crossings, culverts of 100 mm inner diameter, alongwith required no. of collars, PCC and Masonary work as per technical specifications.

40

19520

488

... More
Design, Supply & Erection of Medium duty, HDGI Class B pipe of nominal diameter 100 mm (alongwith HDGI bends wherever required) for bridge crossing, riser pipe for 95Sq.mm & 300Sq.mm XLPE Cable etc., as per technical specifications including supporting arrangement for the pipe and 11 KV Bay.

60

48660

811

... More
Supply and laying of fine river sand of approved quality (except sandy soil) for cushioning of 11KV/LT underground cables.

23.46

50908

2170

... More
Supply of protective covers as per specification below: The Concrete slab shall be machine made using Semi dry concrete that is batched in a fully automatic PLC controlled concrete batching plant and cast in a fully automatic "Vibro -Press" machine with high vibration frequency and hydraulic pressure of 40MT the size of slab shall be 480mmX 250mm x50mm(+/- 2mm) and the concrete grade shall be M30 adhering to IS 456:2000 and shall have a minimum crushing strength of 30N/mm2 (28 days strength) when tested.

1708

230580

135

... More
Earthwork in excavation by mechanical means (hydraulic excavator)/manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sq.m on plan) including disposal of excavated earth lead upto 50 m and lift upto 1.5m disposed earth to be leveled and neatly dressed including providing barricading, danger lighting guarding as directed in :All types of Ordinary rock including all types of laterite rock, blasting prohibited ( RMU foundation plinth)

3

104921

34973.67

... More
Rubble packing with hard laterite stone under floors including watering ramming and consolidating etc. in pipeline trenches and other foundations complete. ( RMU foundation plinth)

0.78

-

-

... More
Providing & laying cement concrete 1:3:6 (1 cement: 3 coarse sand: 6 graded granitic or basaltic stone aggrt. 20 mm. nominal size) excluding cost of centering, shuttering and finishing in:All works upto plinth level ( RMU foundation plinth)

0.78

-

-

... More
Centering & shuttering including Strutting, Propping & removal of forms for :Foundations, Footings, Bases for columns ( RMU foundation plinth)

3.18

-

-

... More
Centering & shuttering including Strutting, Propping & removal of forms for :Foundations, Footings, Bases for columns

30.57

-

-

... More
Providing and laying in position (1:11/2:3) Reinforced cement conrete excluding the cost of centering, shuttering, finishing and reinfrocement (1 cement: 1½ coarse sand:3 graded stone agg 20mm nominal size) : ( RMU foundation plinth)

-

-

-

... More
All works upto plinth level

0.99

-

-

... More
In walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and structs etc. upto floor five level

3.99

-

-

... More
Providing TMT steel reinforcement bars of (SAIL, TATA. VIZAG, JSW Steel Ltd.) ) (Confirming to IS 1786 of 1986) for RCC work (conforming to I.S. 1786 of 1986) including bending, binding & placing in position in all the floors along with the factory made precast concrete cover blocks of specified sizes whose compressive strength is not less than that of surrounding concrete in the structural member. ( RMU foundation plinth)

253.32

-

-

... More
18mm cement plaster in two coats under layer 12mm thick cement plaster 1:5 ( 1 cement : 5 coarse sand) and top layer 6mm thick with cement plaster 1: 3 (1 cement : 3 coarse sand) finished with sponge. ( RMU foundation plinth)

22.77

-

-

... More
Refilling the pipeline/foundation trenches plinth sides, foundation etc. with available excavated earth in layers not exceeding 20 cm depth consolidating each layer ramming and watering lead upto 50 M and all lifts and disposal of surplus earth as directed by Engineer in Charge. ( RMU foundation plinth)

6.99

-

-

... More
Bricks required between double circuit (0.2*0.1*0.1)

4100

38950

9.5

... More
Supply and Erection of Cut point X-arm channel of ISMC 75(75 x 40mm) 1.3 mtr Long for 11KV, Cross arm not to be welded/joined at any place.

3

5877

1959

... More
Supply and Erection of Guard 'X' arm of channel ISMC 75 (75 x 40 mm) 1.5 Mtr Long for 11KV, Cross arm not to be welded/joined at any place.

2

4392

2196

... More
HDGI Top fitting cross arm ISMC channel, ISMC 75 (75 x 40mm), 0.7mts long for 11KV, Cross arm not to be welded/joined at any place.

2

1638

819

... More
Supply and Erection of HDGI 'X' arm clamps for RCC Pole 9 mtr L.A. (Dimensions/specifications as per drawing no. CEE/E-524)

4

1064

266

... More
Supply and Erection of G.I. Pin for 11KV Pin Insulators, Forged G. I pin conforming to IS 2486 part 1 & 2 amended upto date suitable for 11KV glazed porcelain pin pinsulators conforming to IS 731/71 as amended upto date.

3

717

239

... More
Supply and Erection Disc Insulators ball and Socket Type, type A porcelain brown glazed duly cemented at factory with MCI socket cap, forged steel ball pin and supplied with phospor bronze W split pin as per IS 731-1971 as amended upto date.

9

12024

1336

... More
Supply and Erection of Disc insulators 70KN 3 bolted type hardware fitting 70KN suitable for 11KV ball and socket type Disc insulators of 18mm pin , failing load of 70KN. Conform to IS-2486 Part 1-1993, 2486 Part 2-1989 as amended upto date

9

13950

1550

... More
Supply and Erection of HDG.I. stay wire 7/10 SWG, The Stay wire shall comply with the specific requirements of IS: 2141-1979, IS: 4826-1979 & IS: 6594-1974 or the latest versions thereof.

25.19

3551

141

... More
Supply and Erection of HDGI stay clamps for RCC Pole 11.00Mts L.A., (Dimensions/specifications as per drawing no. CEE/E-711)

2

1242

621

... More
Supply and Erection of Earthing complete with 40mm GI Pipe, 2.5 mts long alongwith 20 kgs each salt, charcoal complete.

6

16380

2730

... More
HDGI flat of size 25mm X 5mm for eathing.

48

5568

116

... More
Supply and Erection of GNAT' conductor 7/2.21 mm nominal aluminium area 25mm² (80 amps max. at 40° C)

1.5

37939

25293

... More
GI Street light clamps for 25mm Pipe

36

14508

403

... More
Erection Cost

-

-

-

... More
Erection, Testing and Comissioning of 3 core, 300 sq.mm. aluminium, XLPE insulated, armoured, 11KV Cable.

900

307800

342

... More
Erection, Testing and Comissioning of 3 core, 95sq.mm. aluminium, XLPE armoured, 11KV Cable.

44

8756

199

... More
Erection, Testing and Comissioning of Outdoor type, heat shrinkable, three phase, end termination kit complete, for 11KV XLPE cable of size 3 x 95sq.mm .

2

5296

2648

... More
Erection, Testing and Comissioning of Indoor type, heat shrinkable, three phase, end termination kit complete, for 11KV XLPE cable of size 3 x 95sq.mm.

2

5076

2538

... More
Erection, Testing and Comissioning of Indoor type, heat shrinkable, three phase, end termination kit complete, for 11KV XLPE cable of size 3 x 300sq.mm.

7

17836

2548

... More
Erection, Testing and Comissioning of Outdoor type, heat shrinkable, three phase, end termination kit complete, for 11KV XLPE cable of size 3 x 300sq.mm .

2

5436

2718

... More
3 WAY RMU, 11KV, 630A, 21 kA 3Sec, SF6 Outdoor RMU – 2LBS + 1CB Extensible/Non-Extensible Two (2) Motor operated load break switches (LBSs) with Manual operated earthing switches in SF6 and One (1) vacuum circuit breaker with Electrical closing and tripping along with disconnector and earthing switches SCADA Compatible and base channel. Battery charger along with batteries required for Electrical operations of RMU is in the scope of the Bidder. Each module shall consist of VPIS, FPI in LBS Module (N-1) but not less than 1 no’s per RMU. Suitable arrangement for mounting FRTU, modem or Ethernet Switch/LIU along with battery, battery charger shall be provided in RMU.

2

19440

9720

... More
3 WAY RMU, 11KV, 630A, 21 kA 3Sec, SF6 Outdoor RMU – 3LBS Extensible/Non Extensible Three (3) Motor operated load break switches (LBSs) with Manual operated earthing switches in SF6 SCADA Compatible and base channel. Battery charger along with batteries required for Electrical operations of RMU is in the scope of the Bidder. Each module shall consist of VPIS, FPI in LBS Module (N-1) but not less than 1 no’s per RMU. Suitable arrangement for mounting FRTU , modem or Ethernet Switch/LIU along with battery, battery charger shall be provided in RMU.

1

9720

9720

... More
RCC Cable route marker

5

1280

256

... More
Design, Supply & Erection of RCC Hume pipes for road crossings, nullah crossings, small river crossings, culverts of 100 mm inner diameter, alongwith required no. of collars, PCC and Masonary work as per technical specifications.

40

3080

77

... More
Design, Supply & Erection of Medium duty, HDGI Class B pipe of nominal diameter 100 mm (alongwith HDGI bends wherever required) for bridge crossing, riser pipe for 95Sq.mm & 300Sq.mm XLPE Cable etc., as per technical specifications including supporting arrangement for the pipe and 11 KV Bay.

60

5520

92

... More
Earthwork in excavation by mechanical means (hydraulic excavator)/ manual means in foundation pipeline trenches drain (not exceeding 1.5 mt in width or 10 sq.m on plan) including dressing of sides and ramming of bottoms, lift upto 1.5 m including getting out the excavated soil and disposal of surplus excavated soil as directed within a lead of 50 m(a) for laying of HT/LT cables of various sizes in all kinds of soil, hard rock , providing barricading, danger lighting guarding etc. The trench lengths are as follows:

-

-

-

... More
a. All kinds of soil/rocks/laterite stone

73.8

34538

468

... More
b. All type of ordinary rock including all types of laterite rock, blasting prohibited.

196.8

150158

763

... More
Filling of available excavated earth (excluding rock/stones) in trench in layer not exceeding 0.2mts. Depth, consolidating each deposited layer by ramming and watering lead up to 40mts.

211.25

25350

120

... More
laying of protective covers as per specification below: The Concrete slab shall be machine made using Semi dry concrete that is batched in a fully automatic PLC controlled concrete batching plant and cast in a fully automatic "Vibro -Press" machine with high vibration frequency and hydraulic pressure of 40MT the size of slab shall be 480mmX 250mm x50mm(+/- 2mm) and the concrete grade shall be M30 adhering to IS 456:2000 and shall have a minimum crushing strength of 30N/mm2 (28 days strength) when tested.

1708

102480

60

... More
Laterite Masonary works, Rubber packing with hard laterite stone under floors including ramming and consolidating etc. in pipeline trenches and other foundation complete for double circuit 11KV cable trench(0.2 X 0.9 X 410)

73.8

163171

2211

... More
Erection of 7.5mtr long RCC Pole as per Drawing CEE/C-837

16

59024

3689

... More
Erection of 9mtr long RCC Pole as per Drawing CEE/C-837

2

8816

4408

... More
Erection of 11mtr long RCC Pole as per Drawing CEE/C-698

2

17200

8600

... More
Erection of HDGI 4 pin 'X' arm of ISMC 75 (75 x 40mm) M.S. Channel 1.1 mtr length, Cross arm not to be welded/joined at any place, Galvanising should be hot dipped (Dimensions/specifications as per drawing no: CEE/E/705).

25

6525

261

... More
Erection of HDGI 2 pin 'X' arm of ISMC 75 (75 x 40 mm) M.S. Channel 0.75 mtr length, Cross arm not to be welded/joined at any place, (Dimensions/specifications as per drawing no: CEE/E/704).

23

5336

232

... More
Erection of HDGI V Shape 'X' arm of ISMC 75 (75 x 40mm)

1

338

338

... More
Erection of Cut point X-arm channel of ISMC 75(75 x 40mm) 1.3 mtr Long for 11KV, Cross arm not to be welded/joined at any place.

3

1476

492

... More
Erection of Guard 'X' arm of channel ISMC 75 (75 x 40 mm) 1.5 Mtr Long for 11KV, Cross arm not to be welded/joined at any place.

2

1092

546

... More
HDGI Top fitting cross arm ISMC channel, ISMC 75 (75 x 40mm), 0.7mts long for 11KV, Cross arm not to be welded/joined at any place.

2

456

228

... More
Erection of HDGI 'X' arm clamps for RCC Pole 7.5 mtr S.A., (Dimensions/specifications as per drawing no. CEE/E-523)

6

192

32

... More
Erection of HDGI 'X' arm clamps for RCC Pole 7.5 mtr L.A (Dimensions/specifications as per drawing no. CEE/E-523)

28

896

32

... More
Erection of HDGI 'X' arm clamps for RCC Pole 9 mtr S.A., (Dimensions/specifications as per drawing no. CEE/E-524)

2

90

45

... More
Erection of HDGI 'X' arm clamps for RCC Pole 9 mtr L.A. (Dimensions/specifications as per drawing no. CEE/E-524)

4

180

45

... More
Erection of HDGI X arm clamps for RCC Pole 11.00 mtr S.A, (Dimensions/specifications as per drawing no. CEE/E-711)

5

325

65

... More
Erection of HDGI X arm clamps for RCC Pole 11.00 mtr L.A, (Dimensions/specifications as per drawing no. CEE/E-711)

6

390

65

... More
G.I. NUTS & BOLTS (Full thread and half thread, Hexagon nuts, Hexagon head bolt, hot-dip galvanised steel, as per IS 1363, the amount of zinc deposit over threaded portion of bolts, nuts, screws and washers shall be as per IS:1367, Galvanizing of steel components and accessories shall conform to IS:2629 and IS:2633. )G.I. Nuts & Bolts 100x16mm, 125x16mm, 150x16mm

40

1200

30

... More
Erection of L.T. Shackle insulators: brown glazed shackle insulators of size 100mm x 115mm conforming to fig.No.4 and type 2 of IS: 1445/77 as amended upto date

57

5928

104

... More
Erection of Metal parts for L.T. Shackle insulators: G. I hardware suitable for L. T. shackle insulators of size 100 x 115 mm. conforming to type 2, fig. 4 of IS: 1445/77 as amended upto date

57

5928

104

... More
Erection of L.T. Pin Insulators, L. T. brown glazed porcelain pin insulators of size 100mm x 70mm conforming to type 1 fig 1 of IS:1445/1977 with amendment 2 of Feb.1981 (second revision) as amended upto date

83

8217

99

... More
Erection of G.I. Pin for L.T.Pin Insulators ,Forged G. I. Pin conforming to IS 7935/1975 as amended upto date suitable for L.T. porcelain pin insulator type 1 conforming to fig.1 of IS: 1445/77 with amendment

83

6142

74

... More
Erection of 11KV Pin insulators, 11KV brown glazed porcelain pin insulator with minimum failing load of 5 KN and the minimum creepage distance of 320mm conforming to IS 731-1971 as amended upto date.

3

228

76

... More
Erection of G.I. Pin for 11KV Pin Insulators, Forged G. I pin conforming to IS 2486 part 1 & 2 amended upto date suitable for 11KV glazed porcelain pin pinsulators conforming to IS 731/71 as amended upto date.

3

228

76

... More
Erection Disc Insulators ball and Socket Type, type A porcelain brown glazed duly cemented at factory with MCI socket cap, forged steel ball pin and supplied with phospor bronze W split pin as per IS 731-1971 as amended upto date.

9

1656

184

... More
Erection of Disc insulators 70KN 3 bolted type hardware fitting 70KN suitable for 11KV ball and socket type Disc insulators of 18mm pin , failing load of 70KN. Conform to IS-2486 Part 1-1993, 2486 Part 2-1989 as amended upto date

9

1719

191

... More
Erection of Break insulators 8 KV (44KN) Guy strain insulators of size 90 x 65mm. with minimum failing load of 44 KN and minimum creepage distance of 41 mm. confirming to fig 1 and designation ‘A’ of IS:5300/1969 as amended upto date.

5

485

97

... More
Erection of Break insulators 15 KV (88KN) Guy strain insulators of size 140 x 85mm. with minimum failing load of 88 KN and minimum creepage distance of 57 mm. confirming to fig 1 and designation ‘A’ of IS:5300/1969 as amended upto date.

2

216

108

... More
Erection of G.I. Stay rod & plate LT/11KV line (as per drawing no. CEE/E-465 R)

7

12453

1779

... More
Erection of G.I. Turn Buckle with eye bolt 11 KV (as per drawing no. CEE/E-500)

7

1869

267

... More
Erection of HDG.I. stay wire 7/10 SWG, The Stay wire shall comply with the specific requirements of IS: 2141-1979, IS: 4826-1979 & IS: 6594-1974 or the latest versions thereof.

25.19

1561

62

... More
Erection of HDGI stay clamps for RCC Pole 7.5 mtr S.A., (Dimensions/specifications as per drawing no. CEE/E-523)

2

138

69

... More
Erection of HDGI stay clamps for RCC Pole 7.5 mtr L.A., (Dimensions/specifications as per drawing no. CEE/E-523)

1

69

69

... More
Erection of HDGI stay clamps for RCC Pole 9 mtr L.A., (Dimensions/specifications as per drawing no. CEE/E-524)

2

158

79

... More
Erection of HDGI stay clamps for RCC Pole 11.00Mts L.A., (Dimensions/specifications as per drawing no. CEE/E-711)

2

196

98

... More
Erection of Earthing complete with 40mm GI Pipe, 2.5 mts long alongwith 20 kgs each salt, charcoal complete.

6

14664

2444

... More
HDGI flat of size 25mm X 5mm for eathing.

48

2304

48

... More
Erection of ACSR conductor 'WEASEL' 6 +1 / 2.59 mm nominal aluminium area 30mm² (139 amps max. at 45° C)

0.18

1279

7110

... More
Erection of ACSR conductor 'RACCON' 6 +1 / 4.09 mm nominal aluminium area 80mm² (250 amps max. at 45° C)

0.18

1860

10334

... More
Erection of ANT' conductor 7/3.10 mm nominal aluminium area 50mm² (190 amps max. at 40° C)

1.35

8955

6634

... More
Erection of GNAT' conductor 7/2.21 mm nominal aluminium area 25mm² (80 amps max. at 40° C)

1.5

9274

6183

... More
GI Street light clamps for 25mm Pipe

36

1512

42

... More
G.I. Nuts & Bolts 65x16mm

15

450

30

... More
Removing & refixing of 50W LED street light

18

10800

600

... More
Removing & Refixing of GI bent pipe for Street light

18

2214

123

... More
Removal of 11KV V Shape X Arm Channel

7

1183

169

... More
Removal of Cut point Channel

6

1476

246

... More
Removal of HDGI 4 pin X Arm

15

1957

130.5

... More
Removal of HDGI 2 pin X Arm

15

1740

116

... More
Removal of RCC pole 7.5 mtr

12

22134

1844.5

... More
Removal of RCC pole 11 mtr

10

43000

4300

... More
Removal of RACCON Conductor

1.35

6975

5167

... More
Removal of GNAT Conductor

1.5

4637

3091.5

... More
Removal of ANT Conductor

1.35

4477

3317



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.