Electricity Department Tender

View complete overview of Goa Electricity Department Tender

Electricity Department Tender

Works
Electrical and Electronics
Electrical Works
Eprocure
Opening Date16 Aug 2023
Closing Date11 Sep 2023
Tender Amount₹ 41,31,342 
Notes
Download

Costs

  • EMD

    ₹ 82,627
  • Document Cost

    ₹ 500
  • Tender Fee

    ₹ 6,000

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
Supply of RCC pole 9 mtr as per the drawing No.CEE/E-724 REV-3 as per annexure confirming to IS 785-1998 as amended upto date. The component used for pole shall conform to following IS amended up to date. 1) Ordinary Port land cement 53 grade IS 12269 2) Aggregate IS 383-1970 3) Torsteel IS 1786-7985 4) MS bar IS 432 p 1 & 2-1982

19

159334

8386

... More
Supply of RCC pole 7.5 mtr as per the drawing No.CEE/E-724 REV-3 as per annexure confirming to IS 785-1998 as amended upto date. The component used for pole shall conform to following IS amended up to date. 1) Ordinary Port land cement 53 grade IS 12269 2) Aggregate IS 383-1970 3) Torsteel IS 1786-7985 4) MS bar IS 432 p 1 & 2-1982

4

24368

6092

... More
Supply of 11 KV rated voltange GOAB switches tilting type, outdoor, manually operated, triple pole, single break, conforming to IS: 9921-Part 1 to V as amended up to date and detailed specification eclosed herewith. Each set shall comprise of six pedestal and three tilting post insulators. Insulator should be factory cemented by the manufacturer of the insulators and have minimum 320 mm creepage distance and AB switchs contacts shall be of copper/ copper alloy. The AB switch shall be of following current rating: 200 A

1

23535

23535

... More
Supply of 11 KV , 200 A Horn gap fuse unit (Set of three) shall be as per enclosed drg No. CEE/E-786. Revision 3 and detailed specifications enclosed herewith.

1

10450

10450

... More
Supply of 9 KV, 5 KA nominal discharge current metal oxide gapless distribution class Lightning arrestor conforming to IEC-600994-4 and IS: 3070 part 3 1993 as amended upto date suitable for 11 KV 50 HZ effectively earthed neutral system with necessary mounting arragements and connector suitable to connect ASCR conductor upto overall diameter 12.30 mm

3

9099

3033

... More
Supply of HDGI structure material \\. Each trasformer centre DP consist of HDGI structure material as follows: a) GI channel ISMC 75x40x7.3mm 2.75 mtrs long 2 pieces for incoming line & installation of disc insulators b) GI channel ISMC75x40x7.3mm 2.75mtrs long 2 pieces for GOAB switch c) GI channel ISMC 75x40x7.3mm 2.75 mtrs long 2 pieces for HG fuses d) GI channel ISMC 75x40x7.3mm 2.75 mtrs long 2 pieces for installation of lightening arrestor e) GI channel ISMC 100x50x7.3mm 2.75 mtrs long 2 pieces for installation of Trasformer f) GI channel ISMC 75x40x7.3mm 2.75 mtrs long 2 pieces for side support of trasformer g) GI channel ISMC 75x40x7.3mm 2.75 mtrs long 4 pieces for installation of any other items h) GI channel ISMC 100x40x7.3mm 0.52 mtrs long 2 pieces for installation of Transformer base channel

260

43940

169

... More
Supply of 100KVA 11/0.433KV 3 phase outdoor type ,oil immeresed Aluminium wound level II distribution trasnfromers

1

247700

247700

... More
Supply of LT/11KV Stay set complete 11Mts long RCC pole

2

9227

4613.57

... More
Supply of LT/11KV Stay set complete 9 Mts long RCC pole

16

69864

4366.54

... More
Supply of LT/11KV Stay set complete 7.5 Mts long RCC pole

7

28476

4068.1

... More
Supply of HDGI Top Insulator fitting Cross arm ISMC channel 75 x 40 mm, 0.7 mtr with nut bolts long for 11 mts long RCC pole

7

9269

1324.2

... More
Supply of HDG 11 KV 'V' Shape cross arm of channel ISMC 75 x 40 x 7.3 mm. with HDG Clamp & HDG nut bolts etc. for 11 Mtr. long RCC Pole as pet drg no. CEE/E - 408-R1

5

9871

1974.2

... More
Supply of HDG cut point crosss arm channel ISMC 75 X40 X 6mm of 1.3 mts long with clamps and nuts & bolts for 11 mts RCC pole

1

2464

2464.2

... More
Supply of 1KV Guard Cross arm 1.5Mts long with clamps & nut bolt for 11mtr RCC pole

4

10804

2701.2

... More
Supply of HDG L.T. 4 pin cross arm Channel type as above with HDG clamps & HDG nut bolts etc for 11mts long RCC pole as per drg No.CEE/E-491 and drg no. CEE/E-524

21

33898

1614.2

... More
Supply of HDG L.T. 2 pin cross arm Channel type as above with HDG clamps & HDG nut bolts etc for 11 mts long RCC pole as per drg No.CEE/E-491 and drg no. CEE/E-524

12

12890

1074.2

... More
Supply of HDG L.T. 4 pin cross arm Channel type as above with HDG clamps & HDG nut bolts etc for 9 mts long RCC pole as per drg No.CEE/E-491 and drg no. CEE/E-524

31

45452

1466.2

... More
Supply of HDG L.T. 2 pin cross arm Channel type as above with HDG clamps & HDG nut bolts etc for 9 mts long RCC pole as per drg No.CEE/E-491 and drg no. CEE/E-524

21

19450

926.2

... More
Supply of HDG L.T. 4 pin cross arm Channel type as above with HDG clamps & HDG nut bolts etc for 7.5 mts long RCC pole as per drg No.CEE/E-491 and drg no. CEE/E-524

6

8305

1384.2

... More
Supply of HDG L.T. 2 pin cross arm Channel type as above with HDG clamps & HDG nut bolts etc for 7.5 mts long RCC pole as per drg No.CEE/E-491 and drg no. CEE/E-524

5

4221

844.2

... More
Supply of 11KV Disc Insulators ball and socket type, A porcelain brown glazed duly cemented at factory with MCI socket cap, forged steel ball pin and supplied with Phosphor bronze "W" split pin as per IS 731-1971 as amended upto date. Minimum failing load 70 KN Pin ball diameter 16 mm. Minimum Creepage distance 320 mm with 2 bolted type hardware fitting 70KN suitable for 11 KV ball and socket type disc insulators of 16 mm pin, failing load of 70 KN and suitable for ACSR conductor of size upto 18 mm diameter. The metal parts shall be as per drg No CC/E-482-Rev-2 Benclosed and conform to IS-2486 part 1-1993, 2486 Part-2-1989 as amended upto date.

6

17316

2886

... More
Supply of 11 KV brown glazed porcelain Pin Insulator with minimum failing load of 5 KN and the minimum creepage distance of 320mm conforming to IS 731-1971 as amended upto date. And forged GI pin conforming to IS 2486 part 1 & 2 as amended upto date suitable for 11 KV glazed porcelain pin insulators conforming to IS 731/71 as amended upto date. GI pin shall conform to reference S-165 N fig 5 of IS 2486/(part-II)/74 as amended upto date. Dimension X in said fig shall be 150mm (screwed 100mm). Pin shall be supplied along with one suitable GI hexagonal nut and GI spring washer. Minimum failing load of pin shall be 10 KN.

12

8316

693

... More
Supply of LT brown glazed shackle Insulator of size 100 mm x 115 mm conforming to fig No. 4 and type 2 fo IS: 1445/77 as amended upto date. Minimum failing load shall be 16 KN with GI hardware suitable for LT shackle insulator of size 100 x 115 mm conforming to type 2 fig 4 of IS: 1445/77 as amended upto date. Hardware or fitting shall conform to fig 4 of IS: 7935-1975 as amended upto date comprise fo 2 GI strips, 2 GI bolts and 2 nuts with spring washers.

230

85560

372

... More
Supply of L.T. brown glazed porcelain pin insulators of size 100mmx70mm conforming to type 1 fig 1 of IS: 1445/1977 with amendment 2 of Feb 1981 (second revision) as amended upto date. Minimum failing load shall be 3.5 KN with Forged GI pin conforming to IS 7935/1975 as amended upto date suitable for LT porcelain pin insulator type 1 conforming to fig 1 of IS: 1445/77 with amendment no 2 feb 1981, of size 100 x 70 mm. GI pin shall comprise of GI nut and spring washer and conform to fig No 2 of IS: 7935/1975. Minimum failing load of pin shall be 3.5 KN

150

39450

263

... More
Supply of ACSR Conductor Hard drawn stranded aluminium conductor with galvanized steel wire reinforced conforming to IS: 398(PartII-96) amended upto date of the following sizes. WEASEL 6/1/2.59 (nominal aluminium area 30 Sq.mm.) (139 amp max at 45 °C) for line

0.42

14031

33409

... More
Supply of Earthing complete with chamber as per drg/ No. CEE/E-830. Each earthing should consist as follows a) 40 mm. Dia 2.5 mtr long, class B GI pipe 1 No. b)HDGI nut bolts, clamps 1 set, c)Brick masonary-0.108 Cu.mts d) PVC pipe 50mm dia- 0.2mtr e) Salt-20 Kgs f) Charcoal-20 Kgs g) Excavation-0.864 Cu. Mtr h) refilling-0.74 Cu.mtr as per drg. No.CEE/E-830.

6

16380

2730

... More
Supply of XPLE insulated single core unarmoured cable 50 mm2 for DP earthing.

55

4565

83

... More
Supply of AA"ANT" conductor

9.33

448642

48086

... More
Supply of AA"GNAT" conductor

7.74

195767

25293

... More
Supply of MS Distribution box as per drg No. CEE/E-689 Revision No. 3 along with MCCB 400 A, Bus bar made out of Aluminium strips 40 x 10 mm, kit kat fuses for 4 feeder arrangement

1

63140

63140

... More
Supply of XLPE 1.1KV Armored single core unarmoured cable 185 mm²

48

11760

245

... More
Supply of XLPE 1.1KV 3 & 1/2 XLPE Armoured cable 120 mm²

36

32868

913

... More
Supply of Enamelled danger boards 11000 Volts ,250mm x 200mmm as per drg no. CEE/E-490

2

496

248

... More
Supply of Aluminium crimping Lugs shall conform to IS: 8309-1976 as amended upto date. Lugs shall be made of aluminium of grade IE of IS: 5082/1969 suitable for aluminium cable fo sizes 185 Sq.mm.

8

624

78

... More
Supply of Aluminium crimping Lugs shall conform to IS: 8309-1976 as amended upto date. Lugs shall be made of aluminium of grade IE of IS: 5082/1969 suitable for aluminium cable fo sizes 120 Sq.mm.

9

486

54

... More
Supply of Aluminium crimping Lugs shall conform to IS: 8309-1976 as amended upto date. Lugs shall be made of aluminium of grade IE of IS: 5082/1969 suitable for aluminium cable fo sizes 95 Sq.mm.

3

120

40

... More
Supply of Aluminium crimping Lugs shall conform to IS: 8309-1976 as amended upto date. Lugs shall be made of aluminium of grade IE of IS: 5082/1969 suitable for aluminium cable fo sizes50 Sq.mm.

45

990

22

... More
Supply of FRP Fencing complete with Gate as epr specification for distribution transformer (size 4Mx3Mx2M) with Concreting for FRP Fencing supports with plinth (0.3x0.3x0.5)Cu.m.x12nos Each ratio 1;3;6

1

76667

76667

... More
Supply of Painting of Pole Numbers

29

3025

104.33

... More
B) Estimate for Shifting of Pole in Ward No.IV Poirem i.e. 1.Shifting of pole with LT line from Prakash Majik house to Pandurang Majik house at Arunewada . 2.Shifting of pole with LT line from Shankar Majik house at Arunewada ,Poirem in the jurdisction of Section office Parye .

-

-

-

... More
Supply of RCC pole 9 mtr as per the drawing No.CEE/E-724 REV-3 as per annexure confirming to IS 785-1998 as amended upto date. The component used for pole shall conform to following IS amended up to date. 1) Ordinary Port land cement 53 grade IS 12269 2) Aggregate IS 383-1970 3) Torsteel IS 1786-7985 4) MS bar IS 432 p 1 & 2-1982

10

83860

8386

... More
Supply of LT/11KV Stay set complete 9 Mts long RCC pole

7

30565

4366.54

... More
Supply of HDG L.T. 4 pin cross arm Channel type as above with HDG clamps & HDG nut bolts etc for 9 mts long RCC pole as per drg No.CEE/E-491 and drg no. CEE/E-524

6

8797

1466.2

... More
Supply of HDG L.T. 2 pin cross arm Channel type as above with HDG clamps & HDG nut bolts etc for 9 mts long RCC pole as per drg No.CEE/E-491 and drg no. CEE/E-524

1

926

926.2

... More
Supply of HDG L.T. 4 pin cross arm Channel side bracket type as above with HDG clamps & HDG nut bolts etc for 9 mts long RCC pole as per drg No.CEE/E-491 and drg no. CEE/E-524

6

21898

3649.79

... More
Supply of HDG L.T. 2 pin cross arm Channel side bracket type as above with HDG clamps & HDG nut bolts etc for 9 mts long RCC pole as per drg No.CEE/E-491 and drg no. CEE/E-524

5

9842

1968.53

... More
Supply of LT brown glazed shackle Insulator of size 100 mm x 115 mm conforming to fig No. 4 and type 2 fo IS: 1445/77 as amended upto date. Minimum failing load shall be 16 KN with GI hardware suitable for LT shackle insulator of size 100 x 115 mm conforming to type 2 fig 4 of IS: 1445/77 as amended upto date. Hardware or fitting shall conform to fig 4 of IS: 7935-1975 as amended upto date comprise fo 2 GI strips, 2 GI bolts and 2 nuts with spring washers.

42

15624

372

... More
Supply of L.T. brown glazed porcelain pin insulators of size 100mmx70mm conforming to type 1 fig 1 of IS: 1445/1977 with amendment 2 of Feb 1981 (second revision) as amended upto date. Minimum failing load shall be 3.5 KN with Forged GI pin conforming to IS 7935/1975 as amended upto date suitable for LT porcelain pin insulator type 1 conforming to fig 1 of IS: 1445/77 with amendment no 2 feb 1981, of size 100 x 70 mm. GI pin shall comprise of GI nut and spring washer and conform to fig No 2 of IS: 7935/1975. Minimum failing load of pin shall be 3.5 KN

21

5523

263

... More
Supply of AA"ANT" conductor

0.14

6732

48086

... More
Supply of AA"GNAT" conductor

0.13

3288

25293

... More
Painting of Pole Numbers

10

1043

104.33

... More
C) Estimate for Shifting of Pole in Ward No.V i.e. Poirem 1.Shifting of pole near the house of Keshav Sawant & Suresh Arjun Rane at Sawantwada,Poirem 2.Shifting of pole near the house of Umesh Rama Rane At Sawantwada,Poirem 3. Shifting of pole near the house of Zipaji Shablo Mhalshekar at Mhalshekarwada,Poirem in the jurdisction of Section office Parye .

-

-

-

... More
Supply of RCC pole 9 mtr as per the drawing No.CEE/E-724 REV-3 as per annexure confirming to IS 785-1998 as amended upto date. The component used for pole shall conform to following IS amended up to date. 1) Ordinary Port land cement 53 grade IS 12269 2) Aggregate IS 383-1970 3) Torsteel IS 1786-7985 4) MS bar IS 432 p 1 & 2-1982

15

125790

8386

... More
Supply of LT/11KV Stay set complete 9 Mts long RCC pole

10

43665

4366.54

... More
Supply of HDG L.T. 4 pin cross arm Channel type as above with HDG clamps & HDG nut bolts etc for 9 mts long RCC pole as per drg No.CEE/E-491 and drg no. CEE/E-524

14

20526

1466.2

... More
Supply of HDG L.T. 2 pin cross arm Channel type as above with HDG clamps & HDG nut bolts etc for 9 mts long RCC pole as per drg No.CEE/E-491 and drg no. CEE/E-524

12

11114

926.2

... More
Supply of HDG L.T. 4 pin cross arm Channel side bracket type as above with HDG clamps & HDG nut bolts etc for 9 mts long RCC pole as per drg No.CEE/E-491 and drg no. CEE/E-524

5

18248

3649.79

... More
Supply of HDG L.T. 2 pin cross arm Channel side bracket type as above with HDG clamps & HDG nut bolts etc for 9 mts long RCC pole as per drg No.CEE/E-491 and drg no. CEE/E-524

5

9842

1968.53

... More
Supply of LT brown glazed shackle Insulator of size 100 mm x 115 mm conforming to fig No. 4 and type 2 fo IS: 1445/77 as amended upto date. Minimum failing load shall be 16 KN with GI hardware suitable for LT shackle insulator of size 100 x 115 mm conforming to type 2 fig 4 of IS: 1445/77 as amended upto date. Hardware or fitting shall conform to fig 4 of IS: 7935-1975 as amended upto date comprise fo 2 GI strips, 2 GI bolts and 2 nuts with spring washers.

78

29016

372

... More
Supply of L.T. brown glazed porcelain pin insulators of size 100mmx70mm conforming to type 1 fig 1 of IS: 1445/1977 with amendment 2 of Feb 1981 (second revision) as amended upto date. Minimum failing load shall be 3.5 KN with Forged GI pin conforming to IS 7935/1975 as amended upto date suitable for LT porcelain pin insulator type 1 conforming to fig 1 of IS: 1445/77 with amendment no 2 feb 1981, of size 100 x 70 mm. GI pin shall comprise of GI nut and spring washer and conform to fig No 2 of IS: 7935/1975. Minimum failing load of pin shall be 3.5 KN

38

9994

263

... More
Supply of AA"ANT" conductor

0.28

13464

48086

... More
Supply of AA"GNAT" conductor

0.41

10370

25293

... More
Painting of Pole Numbers

15

1564

104.33

... More
D) Estimate for Shifting of poles along with 3 phase 6 wire LT line in ward No.IV at Kolamwada-Karapur under Village Panchayat Sarvan -Karapur as per request from Village Panchayat Karapur -Sarvan Vide Ref No: VP/KS/2022-2023/4792 Dated 13/01/2023 & the NOTE received from Hon'ble MLA, Mayem Constituency, Goa Legislative Assembly vide ref No.26/Shift-LT line & Poles /VP KS/MLA-MC/23-24 Dated 13/02/2023 , under S.O. Karapur , Sub Division II( R), Sankhalim-Goa

-

-

-

... More
Supply of 9 mtr RCC pole

10

83860

8386

... More
Supply of 7.5 mtr RCC pole for Stud pole

1

6092

6092

... More
Supply of L.A Stay clamps for 7.5 mtr for Stud pole

2

622

311

... More
Supply of Nut & bolt 100X16mm for Stud pole

0.8

182

228

... More
Supply of LT 4 pin cross arm of 75x40 channel with clamps & nut bolt for 9 mtr RCC pole

9

13195

1466.2

... More
Supply of LT 2-pin cross arm of 75x40 channel with clamps & nut bolts for 9 mtr RCC pole

9

8335

926.2

... More
Supply of 4 pin X arm channel side bracket with clamps & nut bolt for 9 mtr RCC pole

5

18248

3649.79

... More
Supply of 2pin X arm channel side bracket with clamps & nut bolt for 9 mtr RCC pole

5

11157

2231.53

... More
Supply of L.T. pin insulators

50

6800

136

... More
Supply of G.I. pin for LT pin insulator

50

6350

127

... More
Supply of L.T. Shackle insulators

40

6680

167

... More
Supply of Metal Parts for LT Shackel Insulator

40

8200

205

... More
Supply of A.A. ' ANT conductor

1.58

75975

48086

... More
Supply of A.A. ' GNAT' conductor

1.71

43251

25293

... More
Supply of stay set 9mtr

7

30565

4366.54

... More
Numbering /Painting of LT poles

10

1043

104.3

... More
E) Estimate for Shifting of poles with 3 phase 5 wire LT line at Survey no.47/0 at Margadhat Sarvan under Village Panchayat Sarvan -Karapur as per request from Village Panchayat Karapur -Sarvan Vide Ref No: VP/KS/BICH/2022-2023/4484 Dated 09/12/2022 & the NOTE received from Hon'ble MLA, MayemConstituency, Goa Legislative Assembly vide ref No.40/Shift-Elect.pole/VP KS/MLA-MC/23-24 Dated 02/1/2023 , under S.O. Karapur , Sub Division II( R), Sankhalim-Goa

-

-

-

... More
Supply of 7.5 mtr RCC pole

14

85288

6092

... More
Supply of 4 pin X arm channel side bracket with clamps & nut bolt for 7.5 mtr RCC pole

4

13551

3387.79

... More
Supply of 2pin X arm channel side bracket with clamps & nut bolt for 7.5 mtr RCC pole

4

7363

1840.93

... More
Supply of A.A. ' ANT conductor

0.09

4327

48086

... More
Supply of A.A. ' GNAT' conductor

0.09

2276

25293

... More
Numbering /Painting of LT poles

14

1460

104.3

... More
Cost of Erection

-

-

-

... More
A) Estimate for Erection of new 100KVA Transformer Centre along with change of conductor to Cater the low voltage problem to Villagers & Agriculture Pumps at Mathwada ,Parye in ,Ward No.1 of Village Panchayat Poirem in the jusrdsciton of Section office Parye under S/D-II( R),Sankhalim-Goa

-

-

-

... More
Erection of RCC pole 11 mtr as per the drawing No.CEE/E-698 REV-3 as per annexure confirming to IS 785-1998 as amended upto date. The component used for pole shall conform to following IS amended up to date. 1) Ordinary Port land cement 53 grade IS 12269 2) Aggregate IS 383-1970 3) Torsteel IS 1786-7985 4) MS bar IS 432 p 1 & 2-1982

6

51600

8600

... More
Erection of RCC pole 9 mtr as per the drawing No.CEE/E-724 REV-3 as per annexure confirming to IS 785-1998 as amended upto date. The component used for pole shall conform to following IS amended up to date. 1) Ordinary Port land cement 53 grade IS 12269 2) Aggregate IS 383-1970 3) Torsteel IS 1786-7985 4) MS bar IS 432 p 1 & 2-1982

19

83752

4408

... More
Erection of RCC pole 7.5 mtr as per the drawing No.CEE/E-724 REV-3 as per annexure confirming to IS 785-1998 as amended upto date. The component used for pole shall conform to following IS amended up to date. 1) Ordinary Port land cement 53 grade IS 12269 2) Aggregate IS 383-1970 3) Torsteel IS 1786-7985 4) MS bar IS 432 p 1 & 2-1982

4

14756

3689

... More
Erection of 11 KV rated voltange GOAB switches tilting type, outdoor, manually operated, triple pole, single break, conforming to IS: 9921-Part 1 to V as amended up to date and detailed specification eclosed herewith. Each set shall comprise of six pedestal and three tilting post insulators. Insulator should be factory cemented by the manufacturer of the insulators and have minimum 320 mm creepage distance and AB switchs contacts shall be of copper/ copper alloy. The AB switch shall be of following current rating: 200 A

1

3971

3971

... More
Erection of 11 KV , 200 A Horn gap fuse unit (Set of three) shall be as per enclosed drg No. CEE/E-786. Revision 3 and detailed specifications enclosed herewith.

1

3368

3368

... More
Erection of9 KV, 5 KA nominal discharge current metal oxide gapless distribution class Lightning arrestor conforming to IEC-600994-4 and IS: 3070 part 3 1993 as amended upto date suitable for 11 KV 50 HZ effectively earthed neutral system with necessary mounting arragements and connector suitable to connect ASCR conductor upto overall diameter 12.30 mm

3

522

174

... More
Erection of HDGI structure material \\. Each trasformer centre DP consist of HDGI structure material as follows: a) GI channel ISMC 75x40x7.3mm 2.75 mtrs long 2 pieces for incoming line & installation of disc insulators b) GI channel ISMC75x40x7.3mm 2.75mtrs long 2 pieces for GOAB switch c) GI channel ISMC 75x40x7.3mm 2.75 mtrs long 2 pieces for HG fuses d) GI channel ISMC 75x40x7.3mm 2.75 mtrs long 2 pieces for installation of lightening arrestor e) GI channel ISMC 100x50x7.3mm 2.75 mtrs long 2 pieces for installation of Trasformer f) GI channel ISMC 75x40x7.3mm 2.75 mtrs long 2 pieces for side support of trasformer g) GI channel ISMC 75x40x7.3mm 2.75 mtrs long 4 pieces for installation of any other items h) GI channel ISMC 100x40x7.3mm 0.52 mtrs long 2 pieces for installation of Transformer base channel

260

12220

47

... More
Erection of100KVA 11/0.433KV 3 phase outdoor type ,oil immeresed Aluminium wound level II distribution trasnfromers

1

11017

11017

... More
Erection of LT/11KV Stay set complete 11Mts long RCC pole

2

5072

2536.34

... More
Erection of LT/11KV Stay set complete 9 Mts long RCC pole

16

39454

2465.88

... More
Erection of LT/11KV Stay set complete 7.5 Mts long RCC pole

7

16826

2403.8

... More
Erection of HDGI Top Insulator fitting Cross arm ISMC channel 75 x 40 mm, 0.7 mtr with nut bolts long for 11 mts long RCC pole

7

2135

305

... More
Erection of HDG 11 KV 'V' Shape cross arm of channel ISMC 75 x 40 x 7.3 mm. with HDG Clamp & HDG nut bolts etc. for 11 Mtr. long RCC Pole as pet drg no. CEE/E - 408-R1

5

2075

415

... More
HDG cut point crosss arm channel ISMC 75 X40 X 6mm of 1.3 mts long with clamps and nuts & bolts for 11 mts RCC pole

1

569

569

... More
Supply & erection of 11KV Guard Cross arm 1.5Mts long with clamps & nut bolt for 11mtr RCC pole

4

2492

623

... More
HDG L.T. 4 pin cross arm Channel type as above with HDG clamps & HDG nut bolts etc for 11mts long RCC pole as per drg No.CEE/E-491 and drg no. CEE/E-524

21

7098

338

... More
HDG L.T. 2 pin cross arm Channel type as above with HDG clamps & HDG nut bolts etc for 11 mts long RCC pole as per drg No.CEE/E-491 and drg no. CEE/E-524

12

3708

309

... More
HDG L.T. 4 pin cross arm Channel type as above with HDG clamps & HDG nut bolts etc for 9 mts long RCC pole as per drg No.CEE/E-491 and drg no. CEE/E-524

31

9858

318

... More
HDG L.T. 2 pin cross arm Channel type as above with HDG clamps & HDG nut bolts etc for 9 mts long RCC pole as per drg No.CEE/E-491 and drg no. CEE/E-524

21

6069

289

... More
HDG L.T. 4 pin cross arm Channel type as above with HDG clamps & HDG nut bolts etc for 7.5 mts long RCC pole as per drg No.CEE/E-491 and drg no. CEE/E-524

6

1830

305

... More
HDG L.T. 2 pin cross arm Channel type as above with HDG clamps & HDG nut bolts etc for 7.5 mts long RCC pole as per drg No.CEE/E-491 and drg no. CEE/E-524

5

1380

276

... More
11 Disc Insulators ball and socket type, A porcelain brown glazed duly cemented at factory with MCI socket cap, forged steel ball pin and supplied with Phosphor bronze "W" split pin as per IS 731-1971 as amended upto date. Minimum failing load 70 KN Pin ball diameter 16 mm. Minimum Creepage distance 320 mm with 2 bolted type hardware fitting 70KN suitable for 11 KV ball and socket type disc insulators of 16 mm pin, failing load of 70 KN and suitable for ACSR conductor of size upto 18 mm diameter. The metal parts shall be as per drg No CC/E-482-Rev-2 Benclosed and conform to IS-2486 part 1-1993, 2486 Part-2-1989 as amended upto date.

6

2250

375

... More
11 KV brown glazed porcelain Pin Insulator with minimum failing load of 5 KN and the minimum creepage distance of 320mm conforming to IS 731-1971 as amended upto date. And forged GI pin conforming to IS 2486 part 1 & 2 as amended upto date suitable for 11 KV glazed porcelain pin insulators conforming to IS 731/71 as amended upto date. GI pin shall conform to reference S-165 N fig 5 of IS 2486/(part-II)/74 as amended upto date. Dimension X in said fig shall be 150mm (screwed 100mm). Pin shall be supplied along with one suitable GI hexagonal nut and GI spring washer. Minimum failing load of pin shall be 10 KN.

12

1824

152

... More
LT brown glazed shackle Insulator of size 100 mm x 115 mm conforming to fig No. 4 and type 2 fo IS: 1445/77 as amended upto date. Minimum failing load shall be 16 KN with GI hardware suitable for LT shackle insulator of size 100 x 115 mm conforming to type 2 fig 4 of IS: 1445/77 as amended upto date. Hardware or fitting shall conform to fig 4 of IS: 7935-1975 as amended upto date comprise fo 2 GI strips, 2 GI bolts and 2 nuts with spring washers.

230

47840

208

... More
L.T. brown glazed porcelain pin insulators of size 100mmx70mm conforming to type 1 fig 1 of IS: 1445/1977 with amendment 2 of Feb 1981 (second revision) as amended upto date. Minimum failing load shall be 3.5 KN with Forged GI pin conforming to IS 7935/1975 as amended upto date suitable for LT porcelain pin insulator type 1 conforming to fig 1 of IS: 1445/77 with amendment no 2 feb 1981, of size 100 x 70 mm. GI pin shall comprise of GI nut and spring washer and conform to fig No 2 of IS: 7935/1975. Minimum failing load of pin shall be 3.5 KN

150

25950

173

... More
ACSR Conductor Hard drawn stranded aluminium conductor with galvanized steel wire reinforced conforming to IS: 398(PartII-96) amended upto date of the following sizes. WEASEL 6/1/2.59 (nominal aluminium area 30 Sq.mm.) (139 amp max at 45 °C) for line

0.42

2986

7110

... More
Earthing complete with chamber as per drg/ No. CEE/E-830. Each earthing should consist as follows a) 40 mm. Dia 2.5 mtr long, class B GI pipe 1 No. b)HDGI nut bolts, clamps 1 set, c)Brick masonary-0.108 Cu.mts d) PVC pipe 50mm dia- 0.2mtr e) Salt-20 Kgs f) Charcoal-20 Kgs g) Excavation-0.864 Cu. Mtr h) refilling-0.74 Cu.mtr as per drg. No.CEE/E-830.

6

14664

2444

... More
XPLE insulated single core unarmoured cable 50 mm2 for DP earthing.

55

3080

56

... More
AA"ANT" conductor

9.33

61895

6634

... More
AA"GNAT" conductor

7.74

47856

6183

... More
MS Distribution box as per drg No. CEE/E-689 Revision No. 3 along with MCCB 400 A, Bus bar made out of Aluminium strips 40 x 10 mm, kit kat fuses for 4 feeder arrangement

1

8795

8795

... More
XLPE 1.1KV Armored single core unarmoured cable 185 mm²

48

8832

184

... More
XLPE 1.1KV 3 & 1/2 XLPE Armoured cable 120 mm²

36

6336

176

... More
Enamelled danger boards 11000 Volts ,250mm x 200mmm as per drg no. CEE/E-490

2

114

57

... More
Aluminium crimping Lugs shall conform to IS: 8309-1976 as amended upto date. Lugs shall be made of aluminium of grade IE of IS: 5082/1969 suitable for aluminium cable fo sizes 185 Sq.mm.

8

760

95

... More
Aluminium crimping Lugs shall conform to IS: 8309-1976 as amended upto date. Lugs shall be made of aluminium of grade IE of IS: 5082/1969 suitable for aluminium cable fo sizes 120 Sq.mm.

9

792

88

... More
Aluminium crimping Lugs shall conform to IS: 8309-1976 as amended upto date. Lugs shall be made of aluminium of grade IE of IS: 5082/1969 suitable for aluminium cable fo sizes 95 Sq.mm.

3

195

65

... More
Aluminium crimping Lugs shall conform to IS: 8309-1976 as amended upto date. Lugs shall be made of aluminium of grade IE of IS: 5082/1969 suitable for aluminium cable fo sizes50 Sq.mm.

45

2295

51

... More
FRP Fencing complete with Gate as epr specification for distribution transformer (size 4Mx3Mx2M) with Concreting for FRP Fencing supports with plinth (0.3x0.3x0.5)Cu.m.x12nos Each ratio 1;3;6

1

35000

35000

... More
Cement concreting 1 : 2:4

2.5

13887

5555

... More
Removing of 9 Mts long RCC pole

2

4408

2204

... More
Removing of 7.5 Mts long RCC pole

22

40579

1844.5

... More
Removing of LT 4 pin cross arm of 75x40 channel with clamps & nut bolt for 11 mtr RCC pole

5

845

169

... More
Removing of LT 2-pin cross arm of 75x40 channel with clamps & nut bolts for 11 mtr RCC pole

5

772

154.5

... More
Removing of LT 4 pin cross arm of 75x40 channel with clamps & nut bolt for 9 mtr RCC pole

4

636

159

... More
Removing of LT 2-pin cross arm of 75x40 channel with clamps & nut bolts for 9 mtr RCC pole

4

578

144.5

... More
Removing of LT 4 pin cross arm of 75x40 channel with clamps & nut bolt for 7.5 mtr RCC pole

24

3660

152.5

... More
Removing of LT 2-pin cross arm of 75x40 channel with clamps & nut bolts for 7.5 mtr RCC pole

24

3312

138

... More
Removing of Pin insulator with GI pin

81

7006

86.5

... More
Removing of Shackle insulator with metal parts

76

7904

104

... More
Removing & Re-stringing of AA WEASEL Conductor

1.68

17917

10665

... More
Removing of AA ANT Conductor

6.14

20366

3317

... More
Removing of AA GNAT Conductor

4.62

14282

3091.5

... More
B) Estimate for Shifting of Pole in Ward No.IV Poirem i.e. 1.Shifting of pole with LT line from Prakash Majik house to Pandurang Majik house at Arunewada . 2.Shifting of pole with LT line from Shankar Majik house at Arunewada ,Poirem in the jurdisction of Section office Parye .

-

-

-

... More
Supply & Erection of RCC pole 9 mtr as per the drawing No.CEE/E-724 REV-3 as per annexure confirming to IS 785-1998 as amended upto date. The component used for pole shall conform to following IS amended up to date. 1) Ordinary Port land cement 53 grade IS 12269 2) Aggregate IS 383-1970 3) Torsteel IS 1786-7985 4) MS bar IS 432 p 1 & 2-1982

10

44080

4408

... More
Supply & erection of LT/11KV Stay set complete 9 Mts long RCC pole

7

17261

2465.88

... More
HDG L.T. 4 pin cross arm Channel type as above with HDG clamps & HDG nut bolts etc for 9 mts long RCC pole as per drg No.CEE/E-491 and drg no. CEE/E-524

6

1908

318

... More
HDG L.T. 2 pin cross arm Channel type as above with HDG clamps & HDG nut bolts etc for 9 mts long RCC pole as per drg No.CEE/E-491 and drg no. CEE/E-524

1

289

289

... More
HDG L.T. 4 pin cross arm Channel side bracket type as above with HDG clamps & HDG nut bolts etc for 9 mts long RCC pole as per drg No.CEE/E-491 and drg no. CEE/E-524

6

5310

885.1

... More
HDG L.T. 2 pin cross arm Channel side bracket type as above with HDG clamps & HDG nut bolts etc for 9 mts long RCC pole as per drg No.CEE/E-491 and drg no. CEE/E-524

5

2345

469.08

... More
LT brown glazed shackle Insulator of size 100 mm x 115 mm conforming to fig No. 4 and type 2 fo IS: 1445/77 as amended upto date. Minimum failing load shall be 16 KN with GI hardware suitable for LT shackle insulator of size 100 x 115 mm conforming to type 2 fig 4 of IS: 1445/77 as amended upto date. Hardware or fitting shall conform to fig 4 of IS: 7935-1975 as amended upto date comprise fo 2 GI strips, 2 GI bolts and 2 nuts with spring washers.

42

8736

208

... More
L.T. brown glazed porcelain pin insulators of size 100mmx70mm conforming to type 1 fig 1 of IS: 1445/1977 with amendment 2 of Feb 1981 (second revision) as amended upto date. Minimum failing load shall be 3.5 KN with Forged GI pin conforming to IS 7935/1975 as amended upto date suitable for LT porcelain pin insulator type 1 conforming to fig 1 of IS: 1445/77 with amendment no 2 feb 1981, of size 100 x 70 mm. GI pin shall comprise of GI nut and spring washer and conform to fig No 2 of IS: 7935/1975. Minimum failing load of pin shall be 3.5 KN

21

3633

173

... More
AA"ANT" conductor

0.14

928

6634

... More
AA"GNAT" conductor

0.13

803

6183

... More
Removing of 7.5 Mts long RCC pole

6

11067

1844.5

... More
Removing of 9 Mts long RCC pole

1

2204

2204

... More
Removing of LT 4 pin cross arm of 75x40 channel with clamps & nut bolt for 7.5 mtr RCC pole

10

1525

152.5

... More
Removing of LT 2-pin cross arm of 75x40 channel with clamps & nut bolts for 7.5 mtr RCC pole

3

414

138

... More
Removing of LT 4 pin cross arm of 75x40 channel with clamps & nut bolt for 9 mtr RCC pole

1

159

159

... More
Removing of LT 2-pin cross arm of 75x40 channel with clamps & nut bolts for 9 mtr RCC pole

1

144

144.5

... More
Removing of AA ANT Conductor

0.91

3018

3317

... More
Removing of AA GNAT Conductor

1.33

4111

3091.5

... More
Re-Stringing of AA ANT Conductor

0.91

6036

6634

... More
Re-stringing of AA GNAT Conductor

1.42

8779

6183

... More
Removing & Re-Stringing of AA ANT Conductor

0.04

398

9951

... More
Removing & Re-stringing of AA GNAT Conductor

0.13

1205

9274.5

... More
Removing of LT shackle insulator with metal parts

27

2808

104

... More
Remvoing of LT Pin insulator with GI pin

21

1816

86.5

... More
C) Estimate for Shifting of Pole in Ward No.V i.e. Poirem 1.Shifting of pole near the house of Keshav Sawant & Suresh Arjun Rane at Sawantwada,Poirem 2.Shifting of pole near the house of Umesh Rama Rane At Sawantwada,Poirem 3. Shifting of pole near the house of Zipaji Shablo Mhalshekar at Mhalshekarwada,Poirem in the jurdisction of Section office Parye .

-

-

-

... More
Supply & Erection of RCC pole 9 mtr as per the drawing No.CEE/E-724 REV-3 as per annexure confirming to IS 785-1998 as amended upto date. The component used for pole shall conform to following IS amended up to date. 1) Ordinary Port land cement 53 grade IS 12269 2) Aggregate IS 383-1970 3) Torsteel IS 1786-7985 4) MS bar IS 432 p 1 & 2-1982

15

66120

4408

... More
Supply & erection of LT/11KV Stay set complete 9 Mts long RCC pole

10

24658

2465.88

... More
HDG L.T. 4 pin cross arm Channel type as above with HDG clamps & HDG nut bolts etc for 9 mts long RCC pole as per drg No.CEE/E-491 and drg no. CEE/E-524

14

4452

318

... More
HDG L.T. 2 pin cross arm Channel type as above with HDG clamps & HDG nut bolts etc for 9 mts long RCC pole as per drg No.CEE/E-491 and drg no. CEE/E-524

12

3468

289

... More
HDG L.T. 4 pin cross arm Channel side bracket type as above with HDG clamps & HDG nut bolts etc for 9 mts long RCC pole as per drg No.CEE/E-491 and drg no. CEE/E-524

5

4425

885.1

... More
HDG L.T. 2 pin cross arm Channel side bracket type as above with HDG clamps & HDG nut bolts etc for 9 mts long RCC pole as per drg No.CEE/E-491 and drg no. CEE/E-524

5

2345

469.08

... More
LT brown glazed shackle Insulator of size 100 mm x 115 mm conforming to fig No. 4 and type 2 fo IS: 1445/77 as amended upto date. Minimum failing load shall be 16 KN with GI hardware suitable for LT shackle insulator of size 100 x 115 mm conforming to type 2 fig 4 of IS: 1445/77 as amended upto date. Hardware or fitting shall conform to fig 4 of IS: 7935-1975 as amended upto date comprise fo 2 GI strips, 2 GI bolts and 2 nuts with spring washers.

78

16224

208

... More
L.T. brown glazed porcelain pin insulators of size 100mmx70mm conforming to type 1 fig 1 of IS: 1445/1977 with amendment 2 of Feb 1981 (second revision) as amended upto date. Minimum failing load shall be 3.5 KN with Forged GI pin conforming to IS 7935/1975 as amended upto date suitable for LT porcelain pin insulator type 1 conforming to fig 1 of IS: 1445/77 with amendment no 2 feb 1981, of size 100 x 70 mm. GI pin shall comprise of GI nut and spring washer and conform to fig No 2 of IS: 7935/1975. Minimum failing load of pin shall be 3.5 KN

38

6574

173

... More
AA"ANT" conductor

0.28

1857

6634

... More
AA"GNAT" conductor

0.41

2535

6183

... More
Removing of 7.5 Mts long RCC pole

13

23978

1844.5

... More
Removing of LT 4 pin cross arm of 75x40 channel with clamps & nut bolt for 7.5 mtr RCC pole

14

2135

152.5

... More
Removing of LT 2-pin cross arm of 75x40 channel with clamps & nut bolts for 7.5 mtr RCC pole

12

1656

138

... More
Removing of AA ANT Conductor

1.79

5937

3317

... More
Removing of AA GNAT Conductor

1.87

5781

3091.5

... More
Re-Stringing of AA ANT Conductor

1.91

12670

6634

... More
Re-stringing of AA GNAT Conductor

1.43

8841

6183

... More
Removing & Re-Stringing of AA ANT Conductor

0.38

3781

9951

... More
Removing & Re-stringing of AA GNAT Conductor

0.38

3524

9274.5

... More
Removing of LT shackle insulator with metal parts

53

5512

104

... More
Remvoing of LT Pin insulator with GI pin

43

3719

86.5

... More
D) Estimate for Shifting of poles along with 3 phase 6 wire LT line in ward No.IV at Kolamwada-Karapur under Village Panchayat Sarvan -Karapur as per request from Village Panchayat Karapur -Sarvan Vide Ref No: VP/KS/2022-2023/4792 Dated 13/01/2023 & the NOTE received from Hon'ble MLA, Mayem Constituency, Goa Legislative Assembly vide ref No.26/Shift-LT line & Poles /VP KS/MLA-MC/23-24 Dated 13/02/2023 , under S.O. Karapur , Sub Division II( R), Sankhalim-Goa

-

-

-

... More
Supply & Erection of 9 mtr RCC pole

10

44080

4408

... More
Supply & Erection of 7.5 mtr RCC pole for Stud pole

1

3689

3689

... More
Supply & Erection of L.A Stay clamps for 7.5 mtr for Stud pole

2

138

69

... More
Supply & Erection Nut & bolt 100X16mm for Stud pole

0.8

24

30

... More
Supply & Erection of LT 4 pin cross arm of 75x40 channel with clamps & nut bolt for 9 mtr RCC pole

9

2862

318

... More
Supply & Erection of LT 2-pin cross arm of 75x40 channel with clamps & nut bolts for 9 mtr RCC pole

9

2601

289

... More
Supply & Erection of 4 pin X arm channel side bracket with clamps & nut bolt for 9 mtr RCC pole

5

4265

853.1

... More
Supply & Erection of 2pin X arm channel side bracket with clamps & nut bolt for 9 mtr RCC pole

5

2595

519.08

... More
Supply & Erection of L.T. pin insulators

50

4950

99

... More
Supply & Erection of G.I. pin for LT pin insulator

50

3700

74

... More
Supply & Erection of L.T. Shackle insulators

40

4160

104

... More
Supply & Erection of Metal Parts for LT Shackel Insulator

40

4160

104

... More
Supply & Erection of A.A. ' ANT conductor

1.58

10481

6634

... More
Supply & Erection of A.A. ' GNAT' conductor

1.71

10572

6183

... More
stay set 9mtr

7

17261

2465.88

... More
Removing of 7.5 mtr RCC pole

7

12911

1844.5

... More
Removing of 4 pin X arm with clamps & nut bolt for 7.5 mtr RCC pole

7

1067

152.5

... More
Removing of 2 pin X arm with clamps & nut bolt for 7.5 mtr RCC pole

7

966

138

... More
Removing of 4 pin X arm with clamps & nut bolt for 9 mtr RCC pole

2

318

159

... More
Removing of 2 pin X arm with clamps & nut bolt for 9 mtr RCC pole

2

289

144.5

... More
Removing of L.T. pin insulators

25

1237

49.5

... More
Removing of G.I. pin for LT pin insulator

25

925

37

... More
Removing of L.T. Shackle insulators

25

1300

52

... More
Removing of Metal Parts for LT Shackel Insulator

25

1300

52

... More
Removing of A.A. ' ANT conductor

1.08

3582

3317

... More
Removing of of A.A. ' GNAT' conductor

1.08

3338

3091.5

... More
E) Estimate for Shifting of poles with 3 phase 5 wire LT line at Survey no.47/0 at Margadhat Sarvan under Village Panchayat Sarvan -Karapur as per request from Village Panchayat Karapur -Sarvan Vide Ref No: VP/KS/BICH/2022-2023/4484 Dated 09/12/2022 & the NOTE received from Hon'ble MLA, MayemConstituency, Goa Legislative Assembly vide ref No.40/Shift-Elect.pole/VP KS/MLA-MC/23-24 Dated 02/1/2023 , under S.O. Karapur , Sub Division II( R), Sankhalim-Goa

-

-

-

... More
Supply & Erection 7.5 mtr RCC pole

14

51646

3689

... More
Re-Erection of 4 pin X arm channel with clamps & nut bolt for 7.5 mtr RCC pole

10

3050

305

... More
Re- Erection of 2pin X arm with clamps & nut bolt for 7.5 mtr RCC pole

10

2760

276

... More
Supply & Erection of 4 pin X arm channel side bracket with clamps & nut bolt for 7.5 mtr RCC pole

4

3488

872.1

... More
Supply & Erection of 2pin X arm channel side bracket with clamps & nut bolt for 7.5 mtr RCC pole

4

1864

466.08

... More
Re- Erection L.T. pin insulators

60

5940

99

... More
Re- Erection of G.I. pin for LT pin insulator

60

4440

74

... More
Re- Erection of L.T. Shackle insulators

20

2080

104

... More
Re-Erection of Metal Parts for LT Shackel Insulator

20

2080

104

... More
Supply & Erection of A.A. ' ANT conductor

0.09

597

6634

... More
Supply & Erection of A.A. ' GNAT' conductor

0.09

556

6183

... More
Removing of 7.5 mtr RCC pole

14

25823

1844.5

... More
Removing of 4 pin X arm with clamps & nut bolt for 7.5 mtr RCC pole

14

2135

152.5

... More
Removing of 2 pin X arm with clamps & nut bolt for 7.5 mtr RCC pole

14

1932

138

... More
Removing of L.T. pin insulators

60

2970

49.5

... More
Removing of G.I. pin for LT pin insulator

60

2220

37

... More
Removing of L.T. Shackle insulators

20

1040

52

... More
Removing of Metal Parts for LT Shackel Insulator

20

1040

52

... More
Removing of A.A. ' ANT conductor

1.78

5904

3317

... More
Removing of of A.A. ' GNAT' conductor

1.19

3678

3091.5

... More
Re-Stringing of A.A. ' ANT conductor

1.78

11808

6634

... More
Re-Stringing of of A.A. ' GNAT' conductor

1.19

7357

6183



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.