Electricity Department Tender

View complete overview of Goa Electricity Department Tender

Electricity Department Tender

Works
Civil And Construction
Electrical and Electronics
Electrical Works
Eprocure
Opening Date7 Dec 2023
Closing Date15 Jan 2024
Tender Amount₹ 11,48,198 
Notes
Download

Costs

  • EMD

    ₹ 22,964
  • Document Cost

    ₹ 2,296
  • Tender Fee

    ₹ 6,000

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
Supply of HDGI 4 pin 'X' arm of ISMC 75 (75 x 40mm) M.S. Channel 1.5 mtr length, Cross arm not to be welded/joined at any place, Galvanising should be hot dipped (Dimensions/specifications as per drawing no: CEE/E/705).

39

43251

1109

... More
Supply of HDGI 2 pin 'X' arm of ISMC 75 (75 x 40 mm) M.S. Channel 0.75 mtr length, Cross arm not to be welded/joined at any place, (Dimensions/specifications as per drawing no: CEE/E/704).

39

22191

569

... More
Supply of HDGI 'X' arm clamps for RCC Pole9.0 mtr L.A., (Dimensions/specifications as per drawing no. CEE/E-524)

22

5852

266

... More
Supply of HDGI 'X' arm clamps for RCC Pole7.5 mtr L.A., (Dimensions/specifications as per drawing no. CEE/E-524)

20

3680

184

... More
Supply of HDGI 'X' arm clamps for 90lb/yd rail pole (Dimensions/specifications as per drawing no. CEE/E-524)

36

24480

680

... More
Supply of L.T. Pin Insulators: L. T. brown glazed porcelain pin insulators of size 100mm x 70mm conforming to type 1 fig 1 of IS:1445/1977 with amendment 2 of Feb.1981 (second revision) as amended upto date. Minimum failing load shall be 3.5kN.

125

17000

136

... More
Supply of G.I. Pin for L.T.Pin Insulators: Forged G. I. Pin conforming to IS 7935/1975 as amended upto date suitable for L.T. porcelain pin insulator type 1 conforming to fig.1 of IS: 1445/77 with amendment No. 2, Feb.1981, of size 100 x 70 mm. G. I. pin shall comprise of G. I. nut and spring washer and conform to fig. No. 2 of IS: 7935/1975. Minimum failing load of pin shall be 3.5 KN.

125

15875

127

... More
Supply of L.T. Shackle insulators: Brown glazed shackle insulators of size 100mm x 115mm conforming to fig.No.4 and type 2 of IS: 1445/77 as amended upto date. Minimum failing load shall be 16kN.

228

38076

167

... More
Supply of Metal parts for L.T. Shackle insulators: G. I hardware suitable for L. T. shackle insulators of size 100 x 115 mm. conforming to type 2, fig. 4 of IS: 1445/77 as amended upto date. Hardware or fitting shall conform to fig. 4 of IS 7935-1975 as amended up to date, comprise of 2 G. I. strips, 2 G. I. bolts and 2 nuts with spring washers. All metal parts including nut bolts should be hot dip galvanized as per IS: 2629/66 as amended up to date. Spring washers shall be electro galvanized, (Galvanising should be hot dipped Galvanised as per IS:2629/66, minimum Zinc coating of 1000 gms/sq.mtr, 140 Microns DFT), suitable for high salinity coastal areas.

228

46740

205

... More
Supply of ANT' conductor 7/3.10 mm nominal aluminium area 50mm² (190 amps max. at 40° C)

5.94

285630

48086

... More
Supply of GNAT' conductor 7/2.21 mm nominal aluminium area 25mm² (80 amps max. at 40° C)

6.44

162760

25293

... More
Supply of HDGI Nut bolt 100x16mm @ 200gm/piece

38.6

8800

228

... More
Removing of 7.5 mtr long RCC pole CEE/E-724

2

-

-

... More
Removing of old 4 Pin X arm

39

-

-

... More
Removing of old 2 Pin X arm

39

-

-

... More
Removing of LT Pin Insulator

125

-

-

... More
Removing of LT Shackle Insulator

228

-

-

... More
Removing of AAC 'ANT' Conductor

6.18

-

-

... More
Removing of AAC 'GNAT' Conductor

6.18

-

-

... More
ERECTION , TESTING and COMMISSIONING

-

-

-

... More
E,T&C of 7.5 mtr. Long RCC pole CEE/E-724

2

7378

3689

... More
E,T&C of HDGI 4 pin 'X' arm of ISMC 75 (75 x 40mm) M.S. Channel 1.5 mtr length, Cross arm not to be welded/joined at any place, Galvanising should be hot dipped (Dimensions/specifications as per drawing no: CEE/E/705).

39

10179

261

... More
E,T&C of HDGI 2 pin 'X' arm of ISMC 75 (75 x 40 mm) M.S. Channel 0.75 mtr length, Cross arm not to be welded/joined at any place, (Dimensions/specifications as per drawing no: CEE/E/704).

39

9048

232

... More
E,T&C of HDGI 'X' arm clamps for RCC Pole9.0 mtr L.A., (Dimensions/specifications as per drawing no. CEE/E-524)

22

990

45

... More
E,T&C of HDGI 'X' arm clamps for RCC Pole7.5 mtr L.A., (Dimensions/specifications as per drawing no. CEE/E-524)

20

640

32

... More
E,T&C of HDGI 'X' arm clamps for 90lb/yd rail pole (Dimensions/specifications as per drawing no. CEE/E-524)

36

3708

103

... More
E,T&C of L.T. Pin Insulators: L. T. brown glazed porcelain pin insulators of size 100mm x 70mm conforming to type 1 fig 1 of IS:1445/1977 with amendment 2 of Feb.1981 (second revision) as amended upto date. Minimum failing load shall be 3.5kN.

125

12375

99

... More
E,T&C of G.I. Pin for L.T.Pin Insulators: Forged G. I. Pin conforming to IS 7935/1975 as amended upto date suitable for L.T. porcelain pin insulator type 1 conforming to fig.1 of IS: 1445/77 with amendment No. 2, Feb.1981, of size 100 x 70 mm. G. I. pin shall comprise of G. I. nut and spring washer and conform to fig. No. 2 of IS: 7935/1975. Minimum failing load of pin shall be 3.5 KN.

125

9250

74

... More
E,T&C of L.T. Shackle insulators: Brown glazed shackle insulators of size 100mm x 115mm conforming to fig.No.4 and type 2 of IS: 1445/77 as amended upto date. Minimum failing load shall be 16kN.

228

23712

104

... More
E,T&C of Metal parts for L.T. Shackle insulators: G. I hardware suitable for L. T. shackle insulators of size 100 x 115 mm. conforming to type 2, fig. 4 of IS: 1445/77 as amended upto date. Hardware or fitting shall conform to fig. 4 of IS 7935-1975 as amended up to date, comprise of 2 G. I. strips, 2 G. I. bolts and 2 nuts with spring washers. All metal parts including nut bolts should be hot dip galvanized as per IS: 2629/66 as amended up to date. Spring washers shall be electro galvanized, (Galvanising should be hot dipped Galvanised as per IS:2629/66, minimum Zinc coating of 1000 gms/sq.mtr, 140 Microns DFT), suitable for high salinity coastal areas.

228

23712

104

... More
E,T&C of ANT' conductor 7/3.10 mm nominal aluminium area 50mm² (190 amps max. at 40° C)

5.94

39405

6634

... More
E,T&C of GNAT' conductor 7/2.21 mm nominal aluminium area 25mm² (80 amps max. at 40° C)

6.44

39787

6183

... More
E,T&C of HDGI Nut bolt 100x16mm @ 200gm/piece

38.6

1158

30

... More
Removing of 7.5 mtr long RCC pole CEE/E-724

2

3689

1844.5

... More
Removing of old 4 Pin X arm

39

5089

130.5

... More
Removing of old 2 Pin X arm

39

4524

116

... More
Removing of LT Pin Insulator

125

10812

86.5

... More
Removing of LT Shackle Insulator

228

23712

104

... More
Removing of AAC 'ANT' Conductor

6.18

20499

3317

... More
Removing of AAC 'GNAT' Conductor

6.18

19105

3091.5

... More
SCHEDULE 2

-

-

-

... More
Supply/Material

-

-

-

... More
Supply of HDGI Top fitting cross arm ISMC channel, ISMC 75 (75 x 40mm), 0.7mts long for 11KV, Cross arm not to be welded/joined at any place.

1

819

819

... More
Supply of HDGI 11 KV V-shape 'X' arm of channel ISMC 75 (75 x 40mm)

1

1469

1469

... More
Supply of HDGI 'X' arm clamps for RCC Pole 11.0 mtr L.A., (Dimensions/specifications as per drawing no. CEE/E-711)

2

828

414

... More
Supply of 11 KV Pin Insulators: 11 KV brown glazed porcelain pin insulator with minimum failing load of 5 KN and the Minimum creepage distance of 320 mm conforming to IS 731-1971 as amended upto date.

3

1362

454

... More
Supply of G.I. Pin for 11 KV Pin Insulators: Forged G. I. Pin conforming to IS 2486 part 1 & 2 as amended upto date suitable for 11 KV glazed porcelain pin insulators conforming to IS: 731/71 as amended upto date. G. I pin shall conform to reference S-165 N fig. 5 of IS: 2486/ (part-II)/74 as amended upto date. Dimensions ‘X’ in said fig. shall be 150 mm (screwed 100 mm). Pin shall be supplied along with one suitable G. I. hexagonal nut and G. I. spring washer. Minimum failing load of pin shall be 10 KN.

3

717

239

... More
Supply of ACSR conductor 'WEASEL' 6 +1 / 2.59 mm nominal aluminium area 30mm² (139 amps max. at 45° C) for DP jumpering and Earthimg.

0.15

-

-

... More
Supply of Earthing as per IS 3043/1966. including supply, erection, testing & comm. of HDGI pipe 8 ft long 40 mm dia class B, fabricated & perforated confirming to I.E. rules of 1956 including alternate layers 30cm thick of charcoal, salt & earth (charcoal & salt --20Kgs each per pit) inclusive of earthwork excavation of size 0.50x0.50x2.5m, backfilling & spreading of excavated earth evenly toget required earth resistance as per enclosed specification

6

16380

2730

... More
Supply of ACSR conductor 'WEASEL' 6 +1 / 2.59 mm nominal aluminium area 30mm² (139 amps max. at 45° C) for DP jumpering and Earthing.

0.15

5011

33409

... More
Supply of G.O.A.B. Switch 11 KV 200 Amps with operating pipe support of class B, 25mm dia., HDGI: G.O.A.B. Switch 11 KV (Single break) : 12 KV rated voltage GOAB switches tilting type, outdoor, manually operated, triple pole, single break, conforming to IS: 9921-Part1 to V as amended upto date and detailed specifications enclosed herewith. Each set shall comprise of six pedestal and three tilting post insulators. Insulator should be factory cemented by the manufactures of the insulators and have minimum 320mm creepage distance and AB switches contacts shall be of copper/copper alloy.

1

23535

23535

... More
Supply of 11 KV , 200 A Horn gap fuse unit (Set of three): Base channel of 75x40 mm (ISMC), HDGI, Insulator 11KV: 3.4.1 The isolators shall be provided with 6 nos. of 24 kV post insulator per pole for 36 kV and 3 nos. of 24 kV post insulator per pole for 12 kV. There will be total of 18 such post insulators in one set of isolator for 36 kV and 9 such post insulators in one set of isolator for 12 kV. These insulators shall conform to latest amendment of IS: 2544 and IS: 5350 (Part-III). Aluminium connector with bi-metallic strip, Horns: Copper (tinted) of 7mm dia, Whisel of copper alloy, fly nut with bolt of brass for connecting fuse wire Earthing terminal with GI nut bolt and plain washer on base channel, Horn holder of copper alloy, Pad of copper alloy

1

10450

10450

... More
Supply of 9 KV, 5 KA Lightning arrestor: Lightning/Surge Arrestors 9 KV, 5 KA nominal discharge current Metal Oxide gapless distribution class lightning arrestor conforming to IEC-60099-4 and IS 3070 Part 3 1993 as amended upto date suitable for 11 KV 50 HZ effectively earthed neutral system with necessary mounting arrangements and connector suitable to connect ACSR conductor upto overall diameter 12.30 mm.

3

9099

3033

... More
Supply of HDGI Structural material

260

43940

169

... More
Supply of Single Core XLPE unarmoured, 1.1 KV grade cable Single Core 50 sq.mm.

50

4150

83

... More
Supply of XLPE cable armoured 3 ½ C X 240 sq.mm 1.1 KV Grade

15

-

-

... More
Supply of XLPE cable armoured 3 ½ C X 120 sq.mm 1.1 KV Grade

24

-

-

... More
Removing of old G.O.A.B. Switch 11 KV 200 Amps

1

-

-

... More
Removing of old 11 KV , 200 A Horn gap fuse unit (Set of three)

1

-

-

... More
Removing of old 9 KV, 5 KA Lightning arrestor

3

-

-

... More
Removing & Rehoisting of 200KVA Distribution Transformer

1

-

-

... More
Removing of old HDGI Structural material

260

-

-

... More
ERECTION , TESTING and COMMISSIONING

-

-

-

... More
E,T&C of HDGI Top fitting cross arm ISMC channel, ISMC 75 (75 x 40mm), 0.7mts long for 11KV, Cross arm not to be welded/joined at any place.

1

228

228

... More
E,T&C of HDGI 11 KV V-shape 'X' arm of channel ISMC 75 (75 x 40mm)

1

338

338

... More
E,T&C of HDGI 'X' arm clamps for RCC Pole 11.0 mtr L.A., (Dimensions/specifications as per drawing no. CEE/E-711)

2

130

65

... More
E,T&C of 11 KV Pin Insulators: 11 KV brown glazed porcelain pin insulator with minimum failing load of 5 KN and the Minimum creepage distance of 320 mm conforming to IS 731-1971 as amended upto date.

3

228

76

... More
E,T&C of G.I. Pin for 11 KV Pin Insulators: Forged G. I. Pin conforming to IS 2486 part 1 & 2 as amended upto date suitable for 11 KV glazed porcelain pin insulators conforming to IS: 731/71 as amended upto date. G. I pin shall conform to reference S-165 N fig. 5 of IS: 2486/ (part-II)/74 as amended upto date. Dimensions ‘X’ in said fig. shall be 150 mm (screwed 100 mm). Pin shall be supplied along with one suitable G. I. hexagonal nut and G. I. spring washer. Minimum failing load of pin shall be 10 KN.

3

228

76

... More
E,T&C of ACSR conductor 'WEASEL' 6 +1 / 2.59 mm nominal aluminium area 30mm² (139 amps max. at 45° C) for DP jumpering and Earthimg.

0.15

1599

10665

... More
Providing,testing&commissioning of Earthing as per IS 3043/1966. including supply, erection, testing & comm. of HDGI pipe 8 ft long 40 mm dia class B, fabricated & perforated confirming to I.E. rules of 1956 including alternate layers 30cm thick of charcoal, salt & earth (charcoal & salt --20Kgs each per pit) inclusive of earthwork excavation of size 0.50x0.50x2.5m, backfilling & spreading of excavated earth evenly toget required earth resistance as per enclosed specification

6

14664

2444

... More
E,T&C of ACSR conductor 'WEASEL' 6 +1 / 2.59 mm nominal aluminium area 30mm² (139 amps max. at 45° C) for DP jumpering and Earthimg.

0.15

1066

7110

... More
E,T&C of G.O.A.B. Switch 11 KV 200 Amps with operating pipe support of class B, 25mm dia., HDGI: G.O.A.B. Switch 11 KV (Single break) : 12 KV rated voltage GOAB switches tilting type, outdoor, manually operated, triple pole, single break, conforming to IS: 9921-Part1 to V as amended upto date and detailed specifications enclosed herewith. Each set shall comprise of six pedestal and three tilting post insulators. Insulator should be factory cemented by the manufactures of the insulators and have minimum 320mm creepage distance and AB switches contacts shall be of copper/copper alloy.

1

3971

3971

... More
E,T&C of 11 KV , 200 A Horn gap fuse unit (Set of three): Base channel of 75x40 mm (ISMC), HDGI, Insulator 11KV: 3.4.1 The isolators shall be provided with 6 nos. of 24 kV post insulator per pole for 36 kV and 3 nos. of 24 kV post insulator per pole for 12 kV. There will be total of 18 such post insulators in one set of isolator for 36 kV and 9 such post insulators in one set of isolator for 12 kV. These insulators shall conform to latest amendment of IS: 2544 and IS: 5350 (Part-III). Aluminium connector with bi-metallic strip, Horns: Copper (tinted) of 7mm dia, Whisel of copper alloy, fly nut with bolt of brass for connecting fuse wire Earthing terminal with GI nut bolt and plain washer on base channel, Horn holder of copper alloy, Pad of copper alloy

1

3368

3368

... More
E,T&C of 9 KV, 5 KA Lightning arrestor: Lightning/Surge Arrestors 9 KV, 5 KA nominal discharge current Metal Oxide gapless distribution class lightning arrestor conforming to IEC-60099-4 and IS 3070 Part 3 1993 as amended upto date suitable for 11 KV 50 HZ effectively earthed neutral system with necessary mounting arrangements and connector suitable to connect ACSR conductor upto overall diameter 12.30 mm.

3

522

174

... More
E,T&C of HDGI Structural material

260

12220

47

... More
E,T&C of Single Core XLPE unarmoured, 1.1 KV grade cable Single Core 50 sq.mm.

50

2800

56

... More
Removing & re-erection of XLPE cable armoured 3 ½ C X 240 sq.mm 1.1 KV Grade

15

6120

408

... More
Removing & re-erection of XLPE cable armoured 3 ½ C X 120 sq.mm 1.1 KV Grade

24

6336

264

... More
Removing of old G.O.A.B. Switch 11 KV 200 Amps

1

1985

1985.5

... More
Removing of old 11 KV , 200 A Horn gap fuse unit (Set of three)

1

1684

1684

... More
Removing of old 9 KV, 5 KA Lightning arrestor

3

261

87

... More
Removing & Rehoisting of 200KVA Distribution Transformer

1

23457

23457

... More
Removing of old HDGI Structural material

260

6110

23.5



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.