Electricity Department Tender

View complete overview of Goa Electricity Department Tender

Electricity Department Tender

Works
Civil And Construction
Eprocure
Opening Date30 Jan 2024
Closing Date16 Feb 2024
Tender Amount₹ 24,28,209 
Notes
Download

Costs

  • EMD

    ₹ 48,564
  • Document Cost

    ₹ 500
  • Tender Fee

    ₹ 4,856

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
Supply of 9 mtr RCC pole

3

25158

8386

... More
Supply of 7.5 mtr RCC pole

4

24368

6092

... More
Supply of 9 mtr RCC pole (Stud pole)

1

8386

8386

... More
Supply of L.A Stay clamps for 9 mtr

2

982

491

... More
Supply of Nut & bolt 100X16mm

0.8

182

228

... More
Supply of LT 4 pin cross arm of 75x40 channel with clamps & nut bolt for 11 mtr RCC pole

4

6456

1614.2

... More
Supply of LT 2-pin cross arm of 75x40 channel with clamps & nut bolts for 11 mtr RCC pole

4

4296

1074.2

... More
Supply of 4 pin X arm channel side bracket with clamps & nut bolt for 11 mtr RCC pole

1

3927

3927.79

... More
Supply of 2 pin X arm channel side bracket with clamps & nut bolt for 11 mtr RCC pole

1

2070

2070.93

... More
Supply of 4 pin X arm channel side bracket with clamps & nut bolt for 9 mtr RCC pole

2

7299

3649.79

... More
Supply of 2 pin X arm channel side bracket with clamps & nut bolt for 9 mtr RCC pole

2

4463

2231.53

... More
Supply of 4 pin X arm channel with clamps & nut bolt for 9 mtr RCC pole

1

1466

1466.2

... More
Supply of 2 pin X arm channel with clamps & nut bolt for 9 mtr RCC pole

1

926

926.2

... More
Supply of 4 pin X arm channel with clamps & nut bolt for 7.5 mtr RCC pole

6

8305

1384.2

... More
Supply of 2 pin X arm channel with clamps & nut bolt for 7.5 mtr RCC pole

9

7597

844.2

... More
Supply of L.T. pin insulators

19

2584

136

... More
Supply of G.I. pin for LT pin insulator

19

2413

127

... More
Supply of L.T. Shackle insulators

74

12358

167

... More
Supply of Metal Parts for LT Shackel Insulator

74

15170

205

... More
Supply of A.A. ' ANT conductor

1.86

89439

48086

... More
Supply of A.A. ' GNAT' conductor

1.82

46033

25293

... More
Supply of A.A. ' WEASEL' conductor

3.2

106908

33409

... More
Supply of V-shape crosss arm with clamps & nut bolt for 11 mtr RCC pole

4

7896

1974.2

... More
Supply of cut point channel with clamps & nut bolt for 11 mtr RCC pole

7

17249

2464.2

... More
Supply of top insulator fitting channel with clamps & nut bolt for 11 mtr RCC pole

6

7945

1324.2

... More
Supply of 11KV Pin insulators with GI pin

15

10395

693

... More
Supply of 11KV Disc insulators 70KN with metral parts

21

60606

2886

... More
Supply of guard cross arm channel with clamps & nut bolt for 11 mtr RCC pole

12

32414

2701.2

... More
Supply of 11KV/LT HDGI stay set complete with HDG stay rod & HDG plate ,break insulator 8KV ,HDG stay clamps,HDG nut olts & HDG stay wire 7/10SWG etc for 9 mtr RCC pole

1

4366

4366.54

... More
Supply of 11KV/LT HDGI stay set complete with HDG stay rod & HDG plate ,break insulator 8KV ,HDG stay clamps,HDG nut olts & HDG stay wire 7/10SWG etc for 11 mtr RCC pole

4

18454

4613.57

... More
Numbering /Painting of LT poles

16

1669

104.33

... More
B) Work of shifting of LT line 3 phase 6 wire & 1 phase 4 wire LT line with poles at Ward No. II, of V.P. Karapur, in the jurisdiction of under S.O. Karapur , Sub Division II( R), Sankhalim-Goa

-

-

-

... More
Supply of 9 mtr RCC pole

4

33544

8386

... More
Supply of 7.5 mtr RCC pole ( Stud pole)

2

12184

6092

... More
Supply of L.A Stay clamps for 7.5 mtr

4

1244

311

... More
Supply of Nut & bolt 100X16mm

1.6

364

228

... More
Supply of 4 pin X arm channel side bracket with clamps & nut bolt for 9 mtr RCC pole

3

10949

3649.79

... More
Supply of 4 pin X arm channel with clamps & nut bolt for 9 mtr RCC pole

2

2932

1466.2

... More
Supply of 2 pin X arm channel with clamps & nut bolt for 9 mtr RCC pole

2

1852

926.2

... More
Supply of L.T. pin insulators

6

816

136

... More
Supply of G.I. pin for LT pin insulator

6

762

127

... More
Supply of L.T. Shackle insulators

31

5177

167

... More
Supply of Metal Parts for LT Shackel Insulator

31

6355

205

... More
Supply of A.A. ' ANT conductor

0.73

35102

48086

... More
Supply of A.A. ' GNAT' conductor

1.11

28075

25293

... More
Supply of 11KV/LT HDGI stay set complete with HDG stay rod & HDG plate ,break insulator 8KV ,HDG stay clamps,HDG nut olts & HDG stay wire 7/10SWG etc for 9 mtr RCC pole

3

13099

4366.54

... More
Numbering /Painting of LT poles

4

417

104.33

... More
C) Work of shifting of 1 phase 4 wire LT line alongwith poles at Madhlawada Podocem in the jurisdiction of Sub Division II( R), Sankhalim-Goa

-

-

-

... More
Supply of RCC pole 9 mtr as per the drawing No.CEE/E-724 REV-3 as per annexure confirming to IS 785-1998 as amended upto date. The component used for pole shall conform to following IS amended up to date. 1) Ordinary Port land cement 53 grade IS 12269 2) Aggregate IS 383-1970 3) Torsteel IS 1786-7985 4) MS bar IS 432 p 1 & 2-1982

18

150948

8386

... More
Supply of LT/11KV Stay set complete 9 Mts long RCC pole

7

30565

4366.54

... More
Supply of HDGI L.T. 4 pin cross arm Channel type as above with HDG clamps & HDG nut bolts etc for 9 mts long RCC pole as per drg No.CEE/E-491 and drg no. CEE/E-524

10

14662

1466.2

... More
Supply of HDGI L.T. 4 pin cross arm Channel side bracket type as above with HDG clamps & HDG nut bolts etc for 9 mts long RCC pole as per drg No.CEE/E-491 and drg no. CEE/E-524

12

43797

3649.79

... More
Supply of LT brown glazed shackle Insulator of size 100 mm x 115 mm conforming to fig No. 4 and type 2 fo IS: 1445/77 as amended upto date. Minimum failing load shall be 16 KN with GI hardware suitable for LT shackle insulator of size 100 x 115 mm conforming to type 2 fig 4 of IS: 1445/77 as amended upto date. Hardware or fitting shall conform to fig 4 of IS: 7935-1975 as amended upto date comprise fo 2 GI strips, 2 GI bolts and 2 nuts with spring washers.

51

18972

372

... More
Supply of L.T. brown glazed porcelain pin insulators of size 100mmx70mm conforming to type 1 fig 1 of IS: 1445/1977 with amendment 2 of Feb 1981 (second revision) as amended upto date. Minimum failing load shall be 3.5 KN with Forged GI pin conforming to IS 7935/1975 as amended upto date suitable for LT porcelain pin insulator type 1 conforming to fig 1 of IS: 1445/77 with amendment no 2 feb 1981, of size 100 x 70 mm. GI pin shall comprise of GI nut and spring washer and conform to fig No 2 of IS: 7935/1975. Minimum failing load of pin shall be 3.5 KN

36

9468

263

... More
Supply of AA"ANT" conductor

0.79

37987

48086

... More
Supply of AA"GNAT" conductor

2.59

65508

25293

... More
Painting of Pole Numbers

18

1877

104.33

... More
D) Work of 11KV HT Naveli feeder and LT line due to widening of MDR-24 near Vedanta Amona and near GPS Chirekhan Kudnem in the jurisdiction of Section Office Kudne under Sub Division-II (R ), Sankhali.

-

-

-

... More
Supply of 7.5 mtr. long RCC Pole

5

30460

6092

... More
Supply of 9 mtr. long RCC Pole

9

75474

8386

... More
Supply of 11 mtr. long RCC Pole

2

32742

16371

... More
Supply of HDGI 2 pin cross Arm channel type

12

6828

569

... More
Supply of HDGI 4 pin cross Arm channel type

13

14417

1109

... More
Supply of GI X arm clamps for LA/ SA for7.5 mtrs RCC pole

8

1472

184

... More
Supply of GI X arm clamps for LA/ SA for 9 mtrs RCC pole

31

8246

266

... More
Supply of GI X arm clamps for LA/ SA for 11 mtrs RCC pole

12

4968

414

... More
Supply of LT Shuckle Insulators with metal Part

54

20088

372

... More
Supply of LT Pin Insulator with G.I.pin

30

7890

263

... More
Supply of Stay set For 7.5 mtrs long RCC pole

3

11930

3976.9

... More
Supply of Stay set For 9 mtrs long RCC pole

6

25652

4275.34

... More
Supply of Stay set For 11 mtrs long RCC pole

2

9044

4522.37

... More
Supply of AAC ANT conductor

0.86

41353

48086

... More
Supply of ACC GNAT Conductor

0.86

21751

25293

... More
Supply of ACSR Weasel conductor

0.65

21715

33409

... More
Supply of ACSR Racoon conductor

0.04

3459

86496

... More
Supply of GI nut and bolts

24

5472

228

... More
Supply of 11 KV V shape X arm channel

6

8814

1469

... More
Supply of Top fitting channel

6

4914

819

... More
Supply of Cut point channel

1

1959

1959

... More
Supply of Stay clamp for 9 mtr Rcc

3

1473

491

... More
Supply of 11KV Pin insulator with GI pin

20

13860

693

... More
Supply of 11KV Disc Insulator with metal parts

6

14190

2365

... More
Supply of Guard Xarm channel

4

8784

2196

... More
Cost of Erection

-

-

-

... More
A)Work of shifting of 11 KV/ 3 phase 6 wire LT line at ward no. IX, of V.P. Karapur Sarvan, as per the request from Sarpanch of V.P. Karapur Sarvan, in the jurisdiction of Section Office Karapur Sub Division-II(R ), Sankhali, Division-V, Bicholim.

-

-

-

... More
Erection of 11 mtr RCC pole

9

77400

8600

... More
Erection of 9 mtr RCC pole

3

13224

4408

... More
Erection of 7.5 mtr RCC pole

4

14756

3689

... More
Erection of 9 mtr RCC pole (Stud pole)

1

4408

4408

... More
Erection of L.A Stay clamps for 9 mtr

2

158

79

... More
Erection Nut & bolt 100X16mm

0.8

24

30

... More
Erection of LT 4 pin cross arm of 75x40 channel with clamps & nut bolt for 11 mtr RCC pole

4

1352

338

... More
Erection of LT 2-pin cross arm of 75x40 channel with clamps & nut bolts for 11 mtr RCC pole

4

1236

309

... More
Erection of 4 pin X arm channel side bracket with clamps & nut bolt for 11 mtr RCC pole

1

901

901.1

... More
Erection of 2 pin X arm channel side bracket with clamps & nut bolt for 11 mtr RCC pole

1

499

499.08

... More
Erection of 4 pin X arm channel side bracket with clamps & nut bolt for 9 mtr RCC pole

2

1706

853.1

... More
Erection of 2 pin X arm channel side bracket with clamps & nut bolt for 9 mtr RCC pole

2

1038

519.08

... More
Erection of 4 pin X arm channel with clamps & nut bolt for 9 mtr RCC pole

1

318

318

... More
Erection of 2 pin X arm channel with clamps & nut bolt for 9 mtr RCC pole

1

289

289

... More
Erection of 4 pin X arm channel with clamps & nut bolt for 7.5 mtr RCC pole

6

1830

305

... More
Erection of 2 pin X arm channel with clamps & nut bolt for 7.5 mtr RCC pole

9

2484

276

... More
Erection of L.T. pin insulators

19

1881

99

... More
Erection of G.I. pin for LT pin insulator

19

1406

74

... More
Erection of L.T. Shackle insulators

74

7696

104

... More
Erection of Metal Parts for LT Shackel Insulator

74

7696

104

... More
Erection of A.A. ' ANT conductor

1.86

12339

6634

... More
Erection of A.A. ' GNAT' conductor

1.82

11253

6183

... More
Erection of A.A. ' WEASEL' conductor

3.2

22752

7110

... More
Erection of V-shape crosss arm with clamps & nut bolt for 11 mtr RCC pole

4

1660

415

... More
Erection of cut point channel with clamps & nut bolt for 11 mtr RCC pole

7

3983

569

... More
Erection of top insulator fitting channel with clamps & nut bolt for 11 mtr RCC pole

6

1830

305

... More
Erection of 11KV Pin insulators with GI pin

15

2280

152

... More
Erection of 11KV Disc insulators 70KN with metral parts

21

7875

375

... More
Erection of guard cross arm channel with clamps & nut bolt for 11 mtr RCC pole

12

7476

623

... More
Erection of 11KV/LT HDG stay set complete with HDG stay rod & HDG plate ,break insulator 8KV ,HDG stay clamps,HDG nut olts & HDG stay wire 7/10SWG etc for 9 mtr RCC pole

1

2465

2465.88

... More
Erection of 11KV/LT HDG stay set complete with HDG stay rod & HDG plate ,break insulator 8KV ,HDG stay clamps,HDG nut olts & HDG stay wire 7/10SWG etc for 11 mtr RCC pole

4

10145

2536.34

... More
Removing of 7.5 mtr RCC pole

2

3689

1844.5

... More
Removing of 9 mtr RCC pole

4

8816

2204

... More
Removing of 11 mtr RCC pole 90lb Rail pole

1

10525

10525

... More
Removing of 4 pin X arm with clamps & nut bolt for 9 mtr RCC pole

4

636

159

... More
Removing of 2 pin X arm with clamps & nut bolt for 9 mtr RCC pole

4

578

144.5

... More
Removing of 4 pin X arm with clamps & nut bolt for 7.5 mtr RCC pole

2

305

152.5

... More
Removing of 2 pin X arm with clamps & nut bolt for 7.5 mtr RCC pole

2

276

138

... More
Removing of 4 pin X arm with clamps & nut bolt for 11 mtr 90lb Rail pole

2

342

171

... More
Removing of 2 pin X arm with clamps & nut bolt for 11mtr 90lb Rail pole

2

313

156.5

... More
Removing of V shape cross arm with clamps & nut bolt for 9 mtr RCC pole

3

592

197.5

... More
Removing of cut point channel with clamps & nut bolt for 11 mtr90lb Rail pole

2

573

286.5

... More
Removing of cut point channel with clamps & nut bolt for 9 mtr RCC pole

2

549

274.5

... More
Removing of guard channel with clamps & nut bolt for 9 mtr RCC pole

2

603

301.5

... More
Removing of 11 KV pin insulator with GI pin

6

456

76

... More
Removing of 11 KV Disc insulator 70KN with metal parts

12

2250

187.5

... More
Removing of L.T. pin insulators

25

1237

49.5

... More
Removing of G.I. pin for LT pin insulator

25

925

37

... More
Removing of L.T. Shackle insulators

20

1040

52

... More
Removing of Metal Parts for LT Shackel Insulator

20

1040

52

... More
Removing of A.A. ' ANT conductor

1.8

5970

3317

... More
Removing of of A.A. ' GNAT' conductor

1.8

5564

3091.5

... More
Removing of of A.A. ' Weasel conductor

1.27

4514

3555

... More
Re-Stringing of A.A. ' ANT conductor

0.71

4710

6634

... More
Re-stringing of of A.A. ' GNAT' conductor

0.71

4389

6183

... More
B) Work of shifting of LT line 3 phase 6 wire & 1 phase 4 wire LT line with poles at Ward No. II, of V.P. Karapur, in the jurisdiction of under S.O. Karapur , Sub Division II( R), Sankhalim-Goa

-

-

-

... More
Erection of 9 mtr RCC pole

4

17632

4408

... More
Erection of 7.5 mtr RCC pole ( Stud pole)

2

7378

3689

... More
Erection of L.A Stay clamps for 7.5 mtr

4

276

69

... More
Erection Nut & bolt 100X16mm

1.6

48

30

... More
Erection of 4 pin X arm channel side bracket with clamps & nut bolt for 9 mtr RCC pole

3

2559

853.1

... More
Erection of 4 pin X arm channel with clamps & nut bolt for 9 mtr RCC pole

2

636

318

... More
Erection of 2 pin X arm channel with clamps & nut bolt for 9 mtr RCC pole

2

578

289

... More
Erection of L.T. pin insulators

6

594

99

... More
Erection of G.I. pin for LT pin insulator

6

444

74

... More
Erection of L.T. Shackle insulators

31

3224

104

... More
Erection of Metal Parts for LT Shackel Insulator

31

3224

104

... More
Erection of A.A. ' ANT conductor

0.73

4842

6634

... More
Erection of A.A. ' GNAT' conductor

1.11

6863

6183

... More
Erection of 11KV/LT HDG stay set complete with HDG stay rod & HDG plate ,break insulator 8KV ,HDG stay clamps,HDG nut olts & HDG stay wire 7/10SWG etc for 9 mtr RCC pole

3

7397

2465.88

... More
Removing of 7.5 mtr RCC pole

3

5533

1844.5

... More
Removing of 4 pin X arm with clamps & nut bolt for 7.5 mtr RCC pole

5

762

152.5

... More
Removing of 2 pin X arm with clamps & nut bolt for 7.5 mtr RCC pole

2

276

138

... More
Removing of L.T. pin insulators

8

396

49.5

... More
Removing of G.I. pin for LT pin insulator

8

296

37

... More
Removing of L.T. Shackle insulators

21

1092

52

... More
Removing of Metal Parts for LT Shackel Insulator

21

1092

52

... More
Removing of A.A. ' ANT conductor

0.61

2023

3317

... More
Removing of of A.A. ' GNAT' conductor

0.8

2473

3091.5

... More
C) Work of shifting of 1 phase 4 wire LT line alongwith poles at Madhlawada Podocem in the jurisdiction of Sub Division II( R), Sankhalim-Goa

-

-

-

... More
Erection of RCC pole 9 mtr as per the drawing No.CEE/E-724 REV-3 as per annexure confirming to IS 785-1998 as amended upto date. The component used for pole shall conform to following IS amended up to date. 1) Ordinary Port land cement 53 grade IS 12269 2) Aggregate IS 383-1970 3) Torsteel IS 1786-7985 4) MS bar IS 432 p 1 & 2-1982

18

79344

4408

... More
Erection of LT/11KV Stay set complete 9 Mts long RCC pole

7

17261

2465.88

... More
Erection of HDG L.T. 4 pin cross arm Channel type as above with HDG clamps & HDG nut bolts etc for 9 mts long RCC pole as per drg No.CEE/E-491 and drg no. CEE/E-524

10

3180

318

... More
Erection of HDG L.T. 4 pin cross arm Channel side bracket type as above with HDG clamps & HDG nut bolts etc for 9 mts long RCC pole as per drg No.CEE/E-491 and drg no. CEE/E-524

12

10621

885.1

... More
Erection of LT brown glazed shackle Insulator of size 100 mm x 115 mm conforming to fig No. 4 and type 2 fo IS: 1445/77 as amended upto date. Minimum failing load shall be 16 KN with GI hardware suitable for LT shackle insulator of size 100 x 115 mm conforming to type 2 fig 4 of IS: 1445/77 as amended upto date. Hardware or fitting shall conform to fig 4 of IS: 7935-1975 as amended upto date comprise fo 2 GI strips, 2 GI bolts and 2 nuts with spring washers.

51

10608

208

... More
Erection of L.T. brown glazed porcelain pin insulators of size 100mmx70mm conforming to type 1 fig 1 of IS: 1445/1977 with amendment 2 of Feb 1981 (second revision) as amended upto date. Minimum failing load shall be 3.5 KN with Forged GI pin conforming to IS 7935/1975 as amended upto date suitable for LT porcelain pin insulator type 1 conforming to fig 1 of IS: 1445/77 with amendment no 2 feb 1981, of size 100 x 70 mm. GI pin shall comprise of GI nut and spring washer and conform to fig No 2 of IS: 7935/1975. Minimum failing load of pin shall be 3.5 KN

36

6228

173

... More
Erection of AA"ANT" conductor

0.79

5240

6634

... More
Erection of AA"GNAT" conductor

2.59

16013

6183

... More
Removing of 7.5 Mts long RCC pole

3

5533

1844.5

... More
Removing of LT 4 pin cross arm of 75x40 channel with clamps & nut bolt for 7.5 mtr RCC pole

7

1067

152.5

... More
Removing of AA ANT Conductor

0.31

1028

3317

... More
Removing of AA GNAT Conductor

0.92

2844

3091.5

... More
Removing of LT shackle insulator with metal parts

6

624

104

... More
Remvoing of LT Pin insulator with GI pin

9

778

86.5

... More
D) Work of 11KV HT Naveli feeder and LT line due to widening of MDR-24 near Vedanta Amona and near GPS Chirekhan Kudnem in the jurisdiction of Section Office Kudne under Sub Division-II (R ), Sankhali.

-

-

-

... More
Erection of 7.5 mtr. long RCC Pole

5

18445

3689

... More
Erection of 9 mtr. long RCC Pole

9

39672

4408

... More
Erection of 11 mtr. long RCC Pole

2

17200

8600

... More
Erection of HDGI 2 pin cross Arm channel type

12

2784

232

... More
Erection of HDGI 4 pin cross Arm channel type

13

3393

261

... More
Erection of GI X arm clamps for LA/ SA for7.5 mtrs RCC pole

8

256

32

... More
Erection of GI X arm clamps for LA/ SA for 9 mtrs RCC pole

31

1395

45

... More
Erection of GI X arm clamps for LA/ SA for 11 mtrs RCC pole

12

780

65

... More
Erection of LT Shuckle Insulators with metal Part

54

11232

208

... More
Erection of LT Pin Insulator with G.I.pin

30

5190

173

... More
Erection of Stay set For 7.5 mtrs long RCC pole

3

7175

2391.8

... More
Erection of Stay set For 9 mtrs long RCC pole

6

14723

2453.88

... More
Erection of Stay set For 11 mtrs long RCC pole

2

5048

2524.34

... More
Erection of AAC ANT conductor

0.86

5705

6634

... More
Erection of ACC GNAT Conductor

0.86

5317

6183

... More
Erection of ACSR Weasel conductor

0.65

4621

7110

... More
Erection of ACSR Racoon conductor

0.04

413

10334

... More
Erection of GI nut and bolts

24

720

30

... More
Erection of 11 KV V shape X arm channel

6

2028

338

... More
Erection of Top fitting channel

6

1368

228

... More
Erection of Cut point channel

1

492

492

... More
Erection of Stay clamp for 9 mtr Rcc

3

237

79

... More
Erection of 11KV Pin insulator with GI pin

20

3040

152

... More
Erection of 11KV Disc Insulator with metal parts

6

1992

332

... More
Erection of Guard Xarm channel

4

2184

546

... More
Removing & Refixing 4 pin X arm channel

6

2349

391.5

... More
Removing & Refixing 2 Pin X arm channel

4

1392

348

... More
Removing & Refixing LT Pin insulator

23

5968

259.5

... More
Removing & Refixing LT shackle Insulator

10

3120

312

... More
Removing Restringing Racoon conductor

1.05

16276

15501

... More
Removing Restringing Weasel conductor

1.28

13651

10665

... More
Removing Restringing ANT conductor

0.84

8358

9951

... More
Removing Restringing GNAT conductor

0.6

5564

9274.5

... More
Removing & refixing Guard X arm channel

4

3276

819

... More
Removing & refixing 11 KV V shape X arm channel

3

1521

507

... More
Removing & refixingTop fitting channel

3

409

136.5

... More
Removing & Refixing Cut point channel

1

738

738

... More
Removing & Refixing Stay clamp 9 mtr Rcc

1

118

118.5

... More
Removing & Refixing 11KV Pin insulator

9

2052

228

... More
Removing & Refixing 11KV Disc Insulator

6

2988

498

... More
Removing Rcc pole 7.5 mtr

11

20289

1844.5

... More
Removing Rcc pole 9 mtr

6

13224

2204

... More
Removing Rcc pole 11 mtr

2

8600

4300

... More
Removing 90lb rail pole 9 mtr

2

21050

10525

... More
Removing 4 pin X arm channel

9

1174

130.5

... More
Removing 2 Pin X arm channel

7

812

116

... More
Removing LT Pin insulator

40

3460

86.5

... More
Removing LT shackle Insulator

14

1456

104

... More
Removing 11 KV V shape X arm channel

4

676

169

... More
Removing Top fitting channel

4

182

45.5

... More
Removing 11KV Pin insulator

12

912

76

... More
Removing Weasel conductor

0.45

1599

3555

... More
Removing ANT conductor

0.71

2355

3317

... More
Removing GNAT conductor

0.71

2194

3091.5



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.