Electricity Department Tender

View complete overview of Goa Electricity Department Tender

Electricity Department Tender

Works
Electrical Cables And Wires
Electrical and Electronics
Eprocure
Opening Date3 Jul 2024
Closing Date22 Jul 2024
Tender Amount₹ 12,93,09,445 
Notes
Download

Costs

  • EMD

    ₹ 22,93,094
  • Document Cost

    ₹ 1,500
  • Tender Fee

    ₹ 6,000

Summary

Work Of Supply, Erection, Testing, And Commissioning Of 11kv 3 Core Xlpe Armored Cable Size 300sq.mm

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
Supply, Laying, Testing & commissioning of 3 core, 95 sq.mm Aluminium, XLPE insulated armoured, 11KV (earthed neutral) Cable for connecting to the distribution transformer centres and 11 KV HT installations and any other equipments. ( From RMU to Transformer / HT Consumers )

484

545468

1127

... More
SETC of 4 way, 11KV, 630Amps, 31kA 3Sec, SF6 Outdoor Ring Main Unit with Four Load Break Switches(LBS) with manual operated earthing switches in SF6 SCADA ompatiable and base channel. Battery charger along with Batteries required for electrical operations of RMU. Each module shall consist of VPIS, FPI in LBS Module (N-1) but not less than 1 no’s per RMU. Suitable arrangement for mounting FRTU , modem or Ethernet Switch/LIU along with battery, battery charger shall be provided in RMU. Auxillary PT as per specification shall be provided in RMU.

1

788000

788000

... More
SETC of 4 WAY RMU, 11KV, 630A, 21 kA 3Sec, SF6 Outdoor RMU – 2LBS + 2CB Extensible/Non Extensible two (2) Motor operated load break switches (LBSs) with Motor operated earthing switches in SF6 and 2 vacuum circuit breaker with Electrical closing and tripping along with disconnector and earthing switches SCADA Compatible and base channel. Battery charger along with batteries required for Electrical operations of RMU is in the scope of the Bidder. Each module shall consist of VPIS, FPI in LBS Module (N-1) but not less than 1 no’s per RMU, Current Transformer and Numerical Relay with communication in all CB module. Suitable arrangement for mounting FRTU , modem or Ethernet Switch/LIU along with battery, battery charger shall be provided in RMU.

1

798000

798000

... More
SETC of 3 WAY RMU, 11KV, 630A, 21 kA 3Sec, SF6 Outdoor RMU – 2LBS + 1CB. Extensible/Non-Extensible Two (2) Motor operated load break switches (LBSs) with Manual operated earthing switches in SF6 and One (1) vacuum circuit breaker with Electrical closing and tripping along with disconnector and earthing switches SCADA Compatible and base channel. Battery charger along with batteries required for Electrical operations of RMU is in the scope of the Bidder. Each module shall consist of VPIS, FPI in LBS Module (N-1) but not less than 1 no’s per RMU. Suitable arrangement for mounting FRTU, modem or Ethernet Switch/LIU along with battery, battery charger shall be provided in RMU.

20

11300000

565000

... More
SETC of 3 WAY RMU, 11KV, 630A, 21 kA 3Sec, SF6 Outdoor RMU – 3LBS Extensible/Non Extensible Three (3) Motor operated load break switches (LBSs) with Manual operated earthing switches in SF6 SCADA Compatible and base channel. Battery charger along with batteries required for Electrical operations of RMU is in the scope of the Bidder. Each module shall consist of VPIS, FPI in LBS Module (N-1) but not less than 1 no’s per RMU. Suitable arrangement for mounting FRTU , modem or Ethernet Switch/LIU along with battery, battery charger shall be provided in RMU.

5

2720000

544000

... More
Supply and termination of out door type end termination heat shrinkable kit for 11KV XLPE cable of size 3x300 sq.mm including sockets / lugs / connectors etc alongwith cable glands at 11KV take - off gantry at 33/11KV sub-station & and at O/H Poles.

1

11667

11667

... More
Supply and termination of indoor type end termination heat shrinkable kit for 11KV XLPE cable of size 3x300 sq.mm including sockets / lugs / connectors etc alongwith cable glands at 11KV Ring Main Unit & two way on load switch (DEOS). ( 3 for each DEOS & 2 for each RMU )

63

556920

8840

... More
Supply, erection, testing & commissioning of termination of indoor type end termination heat shrinkable kit for 11KV XLPE cable of size 95sqmm including sockets / lugs / connectors etc alongwith cable glands at 11KV Ring Main Unit.

22

148082

6731

... More
Supply, erection, testing & commissioning of termination of outdoor type end termination heat shrinkable kit for 11KV XLPE cable of size 95sqmm including sockets / lugs / connectors etc alongwith cable glands at Transformer centre AB Switch

22

223344

10152

... More
Supply, erection, testing & commissioning of XLPE heat shrinkable straight through jointing kit for 300 sq.mm, 3 core, 11KV XLPE cable.

36

1064124

29559

... More
Laying of 11KV/LT UG cables by Trenchless technology by adopting horizontal directional drilling (HDD Method). The work includes preparation of site, Boring as well as drawing of cable In Hard/Laterite stone Soil with minimum 8" bore size, including Supply & erection of HDPE pipe 110mm, PN6, PE80, wall thickness 6.5mm(minimum) as per IS 4984:1995 amendment 2016. The depth shall be 1.650m to 1.850m (1650mm-1850mm) only except at entry and exit pits where minimum depth shall be 1200mm.

17718.8

63787680

3600

... More
Supply and laying of precast 250 mm dia RCC Pipe as per GSR 2020 (Roads) item nn 1909.

280

225960

807

... More
Supply & laying of Underground Cable protective cover as per specification as given below: The concrete slab shall be machine made using semi dry concrete that is batched in a fully automatic PLC controlled concrete batching plant and cast in fully automatic "Vibro Press" machine with a high vibration frequency and hydraulic pressure of 40MT, the sie of slab shall be 480mm x 250mm x 50mm, (+/-2mm) and the concrete grade shall be M30 adhering to IS-456:2000 and shall have a minimum crushing strength of 30N/mm2 (28days strength) when tested. at 50 Mts each

280

37800

135

... More
Supply and laying of river sand for cushioning of 11 KV XLPE cable. 0.2 x 0.45 x 425mtr

25.2

54684

2170

... More
Supply and laying RCC Cable route marker (400 x 900 x 100mm) (as per CEE approved drawing,) (for entire route length) at 50 Mts each

170

89760

528

... More
GI Riser Pipe 100mm, class B, for 95 sq. mm. cable support , 3Mts. for each DP.

92

74612

811

... More
Supply and erection Earthing complete with 40mm GI Pipe, 2.5 mts long alongwith 20 kgs each salt, charcoal complete., inserted in pit excavated of size not less than 500mm x 500mm x 2400mm as per Drg No. CEE/E-829( 2 for each RMU & DEOS).

54

147420

2730

... More
Supply and laying HDG Strip 25mm x 5 mm for connecting earthing for RMU & DEOS (6 mts for each RMU)

138

16008

116

... More
Supply and laying of Bricks class design 75 kg/cm2 (1st class wire cut)for saparation of 2 cables(taken as 40% of route length)

170

1615

9.5

... More
Warning tape (20% of route length)

3.5

52500

15000

... More
Laterite Masonary Works:- Rubble packing with hard Laterite stone under floors including watering ramming and consolidating etc. in pipeline trenches and other fondations complete, for: Single Circuit 11KV Cable Trench ( 0.2 x 0.7 x 1.00) i.e. 0.14cu mts per RM

61

134871

2211

... More
Numbering of RMU/DEOS

23

2399

104.33

... More
COST OF ERECTION

-

-

-

... More
Supply, Laying, Testing & commissioning of 3 core, 95 sq.mm Aluminium, XLPE insulated armoured, 11KV (earthed neutral) Cable for connecting to the distribution transformer centres and 11 KV HT installations and any other equipments. ( From RMU to Transformer / HT Consumers )

484

96316

199

... More
SETC of 4 way, 11KV, 630Amps, 31kA 3Sec, SF6 Outdoor Ring Main Unit with Four Load Break Switches(LBS) with manual operated earthing switches in SF6 SCADA ompatiable and base channel. Battery charger along with Batteries required for electrical operations of RMU. Each module shall consist of VPIS, FPI in LBS Module (N-1) but not less than 1 no’s per RMU. Suitable arrangement for mounting FRTU , modem or Ethernet Switch/LIU along with battery, battery charger shall be provided in RMU. Auxillary PT as per specification shall be provided in RMU.

1

9720

9720

... More
SETC of 4 WAY RMU, 11KV, 630A, 21 kA 3Sec, SF6 Outdoor RMU – 2LBS + 2CB Extensible/Non Extensible two (2) Motor operated load break switches (LBSs) with Motor operated earthing switches in SF6 and 2 vacuum circuit breaker with Electrical closing and tripping along with disconnector and earthing switches SCADA Compatible and base channel. Battery charger along with batteries required for Electrical operations of RMU is in the scope of the Bidder. Each module shall consist of VPIS, FPI in LBS Module (N-1) but not less than 1 no’s per RMU, Current Transformer and Numerical Relay with communication in all CB module. Suitable arrangement for mounting FRTU , modem or Ethernet Switch/LIU along with battery, battery charger shall be provided in RMU.

1

9720

9720

... More
SETC of 3 WAY RMU, 11KV, 630A, 21 kA 3Sec, SF6 Outdoor RMU – 2LBS + 1CB. Extensible/Non-Extensible Two (2) Motor operated load break switches (LBSs) with Manual operated earthing switches in SF6 and One (1) vacuum circuit breaker with Electrical closing and tripping along with disconnector and earthing switches SCADA Compatible and base channel. Battery charger along with batteries required for Electrical operations of RMU is in the scope of the Bidder. Each module shall consist of VPIS, FPI in LBS Module (N-1) but not less than 1 no’s per RMU. Suitable arrangement for mounting FRTU, modem or Ethernet Switch/LIU along with battery, battery charger shall be provided in RMU.

20

194400

9720

... More
SETC of 3 WAY RMU, 11KV, 630A, 21 kA 3Sec, SF6 Outdoor RMU – 3LBS Extensible/Non Extensible Three (3) Motor operated load break switches (LBSs) with Manual operated earthing switches in SF6 SCADA Compatible and base channel. Battery charger along with batteries required for Electrical operations of RMU is in the scope of the Bidder. Each module shall consist of VPIS, FPI in LBS Module (N-1) but not less than 1 no’s per RMU. Suitable arrangement for mounting FRTU , modem or Ethernet Switch/LIU along with battery, battery charger shall be provided in RMU.

5

48600

9720

... More
Supply and termination of out door type end termination heat shrinkable kit for 11KV XLPE cable of size 3x300 sq.mm including sockets / lugs / connectors etc alongwith cable glands at 11KV take - off gantry at 33/11KV sub-station & and at O/H Poles.

1

2718

2718

... More
Supply and termination of indoor type end termination heat shrinkable kit for 11KV XLPE cable of size 3x300 sq.mm including sockets / lugs / connectors etc alongwith cable glands at 11KV Ring Main Unit & two way on load switch (DEOS). ( 3 for each DEOS & 2 for each RMU )

63

160524

2548

... More
Supply, erection, testing & commissioning of termination of indoor type end termination heat shrinkable kit for 11KV XLPE cable of size 95sqmm including sockets / lugs / connectors etc alongwith cable glands at 11KV Ring Main Unit.

22

55836

2538

... More
Supply, erection, testing & commissioning of termination of outdoor type end termination heat shrinkable kit for 11KV XLPE cable of size 95sqmm including sockets / lugs / connectors etc alongwith cable glands at Transformer centre AB Switch

22

58256

2648

... More
Supply, erection, testing & commissioning of XLPE heat shrinkable straight through jointing kit for 300 sq.mm, 3 core, 11KV XLPE cable.

36

133668

3713

... More
Excavation of trench of size 1.1 x 0.45 x (280) Mts for laying of 1 runs of HT 95sqmm cable under ground which includes digging in All kinds of soil

138.6

64864

468

... More
Filling of available excavated earth (excluding rock/stones in trench, plinth, sides, foundations etc. in layer not exceeding 0.15mts. Depth, consolidating each deposited layer by ramming and watering lead up to 50 mts.0.9 x 0.45 x 425mtr

113.4

13608

120

... More
Disposal of surplus excavated soil / material by mechanical transportation and including loading and unloading, stacking, levelling as directed within a distance of 2500 mts.

25.2

3170

125.82

... More
Supply and laying of precast 250 mm dia RCC Pipe as per GSR 2020 (Roads) item nn 1909.

280

71120

254

... More
Supply & laying of Underground Cable protective cover as per specification as given below: The concrete slab shall be machine made using semi dry concrete that is batched in a fully automatic PLC controlled concrete batching plant and cast in fully automatic "Vibro Press" machine with a high vibration frequency and hydraulic pressure of 40MT, the sie of slab shall be 480mm x 250mm x 50mm, (+/-2mm) and the concrete grade shall be M30 adhering to IS-456:2000 and shall have a minimum crushing strength of 30N/mm2 (28days strength) when tested. at 50 Mts each

280

16800

60

... More
Supply and laying RCC Cable route marker (400 x 900 x 100mm) (as per CEE approved drawing,) (for entire route length) at 50 Mts each

170

43520

256

... More
GI Riser Pipe 100mm, class B, for 95 sq. mm. cable support , 3Mts. for each DP.

92

8464

92

... More
Supply and erection Earthing complete with 40mm GI Pipe, 2.5 mts long alongwith 20 kgs each salt, charcoal complete., inserted in pit excavated of size not less than 500mm x 500mm x 2400mm as per Drg No. CEE/E-829( 2 for each RMU & DEOS).

54

131976

2444

... More
Supply and laying HDG Strip 25mm x 5 mm for connecting earthing for RMU & DEOS (6 mts for each RMU)

138

6624

48

... More
Civil Work of 3Way RMU Plinth

-

-

-

... More
Earthwork in excavation by mechanical means ( hydraulic excavator)/manual means over areas( exceeding 30cm in depth, 1.5min width as well as 10sqmm on plan) including disposal of excavated earth lead upto 50m and lift upto 1.5m disposed earth to be leveled and neatly dressed including providing barrigading, danger lighting guarding as directed in : b) All types of Ordinary rock including all types of laterite rock, blasting prohibited

156.75

100163

639

... More
Rubble packing with hard laterite stone under floors including watering ramming and consolidating etc, in pipeline trenches and other foundations complete.

28.5

63013

2211

... More
Providing & laying of Cement Concrete 1:3:6( 1 Cement: 3Coarse Sand: 6 graded granitic or Basaltic Stone aggrt. 20mm. Nominal size) excluding cost of centering, shuttering and finishing in; a) All works upto plinth level.

14.25

90131

6325

... More
Providing & laying in position ( 1:11/2:3) Rainforced cement concrete excluding the cost of centering, shuttering, finishing and reinforcement ( 1 Cement: 1.5 Coarse sand: 3 graded stone agg 20mm nominal size) a) All work upto plinth level.

56.5

405557

7178

... More
Providing TMT steel reinforcement bar of ( SAIL, TATA, VIZAG, JSW Steel ltd) ( Confirming to IS 1786 of 1986) for RCC work ( confirming to IS 1786 of 1986) including bending & placing in position in all the floors along with the factory made precast concrete cover blocks of specified sizes whose comprehensive strength is not less than that of surrounding concrete in the structural member.

6093.75

639843

105

... More
Centering & shuttering including struttings, propping etc. and removal of framwork for:

-

-

-

... More
Foundations, footings, bases for columns.

32

13024

407

... More
Vertical Surfaces such as retaining walls, return walls, Partitions, walls ( any thickness) including attached Pilasters, Buttresses, Plinth and string courses, Fillets and the like.

354.5

169805

479

... More
12mm Cement plaster 1:4 ( 1Cement : 4 Fine Sand).

171.5

38244

223

... More
Refilling the pipeline/foundation trenches plinth sides, foundation etc. with available excavated earth in layers not exceeding 20cm depth consolidating each layer ramming and watering lead upto 50M and all lifts and disposal of surplus earth as directed by Engineer in charge.

86.25

21131

245

... More
Civil Work of 4Way RMU Plinth

-

-

-

... More
Earthwork in excavation by mechanical means ( hydraulic excavator)/manual means over areas( exceeding 30cm in depth, 1.5min width as well as 10sqmm on plan) including disposal of excavated earth lead upto 50m and lift upto 1.5m disposed earth to be leveled and neatly dressed including providing barrigading, danger lighting guarding as directed in : a) All kinds of Soil rock including all types of laterite rock, blasting prohibited

12.54

3586

286

... More
Rubble packing with hard laterite stone under floors including watering ramming and consolidating etc, in pipeline trenches and other foundations complete.

2.28

5041

2211

... More
Providing & laying of Cement Concrete 1:3:6( 1 Cement: 3Coarse Sand: 6 graded granitic or Basaltic Stone aggrt. 20mm. Nominal size) excluding cost of centering, shuttering and finishing in; a) All works upto plinth level.

1.14

7210

6325

... More
Providing & laying in position ( 1:11/2:3) Rainforced cement concrete excluding the cost of centering, shuttering, finishing and reinforcement ( 1 Cement: 1.5 Coarse sand: 3 graded stone agg 20mm nominal size) a) All work upto plinth level.

4.52

32444

7178

... More
Providing TMT steel reinforcement bar of ( SAIL, TATA, VIZAG, JSW Steel ltd) ( Confirming to IS 1786 of 1986) for RCC work ( confirming to IS 1786 of 1986) including bending & placing in position in all the floors along with the factory made precast concrete cover blocks of specified sizes whose comprehensive strength is not less than that of surrounding concrete in the structural member.

487.5

51187

105

... More
Centering & shuttering including struttings, propping etc. and removal of framwork for:

-

-

-

... More
Foundations, footings, bases for columns.

2.56

1041

407

... More
Vertical Surfaces such as retaining walls, return walls, Partitions, walls ( any thickness) including attached Pilasters, Buttresses, Plinth and string courses, Fillets and the like.

28.36

13584

479

... More
12mm Cement plaster 1:4 ( 1Cement : 4 Fine Sand).

13.72

3059

223

... More
Refilling the pipeline/foundation trenches plinth sides, foundation etc. with available excavated earth in layers not exceeding 20cm depth consolidating each layer ramming and watering lead upto 50M and all lifts and disposal of surplus earth as directed by Engineer in charge.

6.9

1690

245

... More
THE WORK OF DISMANTLING OF EXISTING 11KV SINGLE CIRCUIT OVERHEAD LINE OF 11KV SODIEM FEEDER FROM 33/11KV MAPUSA S/S

-

-

-

... More
Dismantling of of RCC pole 11 mtr

82

352600

4300

... More
Dismantling of of RCC pole 9.0 mtr

74

163096

2204

... More
Dismantling of Rail pole 90lb/yd 11mtr

8

84200

10525

... More
GOAB Switch 11KV ( Single Break) 12KV rated voltange GOAB switches tilting type, outdoor, manually operated, triple pole, single break current rating: 400 A

15

29917

1994.5

... More
HDGI Structure Material for G.O.A.B. Switch 11 KV 400 Amps

675

15862

23.5

... More
HDG 11KV 'V' Shape cross arm of channel ISMC 75 x 40 x 7.3 mm.

119

20111

169

... More
HDGI Top Insulator fitting Cross arm ISMC channel 75 x 40 mm, 0.7 mtr long

119

13566

114

... More
HDG cut point channel cross arm chaneel ISMC 75X40x7.3mm of 1.3 mts long

43

10578

246

... More
HDG S.A stay clamp for 11 mts long RCC pole for cut point

23

747

32.5

... More
HDG L.A stay clamp for 9 mts long RCC pole for cut point pole

20

790

39.5

... More
HDG guard cross arm of channel ISMC 75X40X7.5 mm of 1.5 mts long

73

19929

273

... More
11KV brown glazed porcelain Pin Insulator

357

13566

38

... More
Forged GI pin suitable for 11 KV glazed porcelain Pin Insulators

357

13566

38

... More
11KV Disc Insulators ball afailing load of 45 KN and suitable for ACSR conductor of size upto 18 mm diameter.

291

22407

77

... More
Metal parts for 45 KN Disc Insulator

291

25899

89

... More
ACSR Conductor alumininium WEASEL 6/1/2.59

22.5

79987

3555

... More
ACSR ConductorRACOON( 6/1/4.09 )

14.19

73319

5167

... More
11KV/LT HDG.I. stay wire 7/10 SWG

314

9734

31

... More
HDGI 11KV/LT Turn buckle with eye bolt CEE/E-466

77

10279

133.5

... More
Break insulator, 8KV 44KN

77

3734

48.5

... More
HDGI stay clamps for RCC Pole 11.0Mts S.A.CEE-E-711

35

1715

49

... More
HDG L.A stay clamp for 9 mts long RCC pole as per drg No. CEE/E-524

39

1540

39.5

... More
HDGI stay clamps for Rail pole 90lb/yd

3

154

51.5

... More
HDGI cross arm clamp LA/SA for 11 mt long RCC pole

119

3867

32.5

... More
HDGI Cross arm clampLA/SA for 9.0 mt long RCC pole

98

2205

22.5

... More
HDGI Cross arm clamp LA/SA for long 90 lb/yd Rail pole

18

621

34.5

... More
HDG nut bolt of all sizes

190

2850

15



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.