Electricity Department Tender
View complete overview of Goa Electricity Department Tender
Costs
EMD
₹ 18,920Document Cost
₹ 500Tender Fee
₹ 1,892
Summary
The Work Of Laying Of 11 Kv Ribandar Feeder From Ktc Rmu To Heera Petrol Pump Rmu Under The Jurisdiction Of Sd-ii, Panaji
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2024_ED_17877_1Bid Award Id
ViewTender No
10(2024-25)Tender Authority
Electricity Department ViewPurchaser Address
-
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
BOQ Items
Back Filling of the available excavated earth (excluding rock) in trenches, plinth, sides, foundation etc. in layer work exceeding 0.2 mtr. depth consolidating each deposited layer by ramming and watering. (Excavation 151.35)-(sand 32.28)-(Cable 4.18)-(RCC cover 6.88)-(Bricks 34.5)(0.9*0.45*60)
28.35
-
-
Supplying of sand. (0.45*0.2*60)
6.3
2170
13671
Disposal of earth at a distance of 3000 mtrs
6.3
125
792.67
Supply of 11KV,3 core x 300 mm2 XLPE HT cable excluding cable end termination.
180
2338
420840
Supply of 11 Kv cable end termination kits indoor type suitable for: 3 core X 300 mm2 cable XLPE
1
8840
8840
Supply of heat shrinkable straight through jointing kit suitable for 3 C x 300 sq.mm XLPE cable
1
29559
29559
Supply of underground cable protective cover as per specs. The concrete sla shall be machine madeusing semi dry concrete that is batched in afully automatic PLC controlled concrete batching plant and cast in a fully automatic "Vibra press"machine with high vibration frequency and hydraulic pressure of 40MT , size of the slab shall be 480 mm*250 mm*50 mm and the concrete grade shall be M 30vadhiring to IS 4561:2000 shall have a minimum crushing strength of 30 N/mm2( 28 days strength when tested
146
135
19710
Supply of RCC Hume Pipe 250 mm dia with required no. of collars, for road crossing.
10
807
8070
RCC cable Route marker (400x900x100 mm)
2
528
1056
Providing in position cement concrete 1:2:4 (1 cement : 2 coarse sand: 4 graded granitic or basaltic stone aggregate 40 m nominal size for reinstatement.
9.54
5555
52994.7
Errection Testing & Commissioning Earth work excavation in foundation trenches or drain including opening of roads, chamber, pavements and soiling, ramming, leveling of bottoms, making bottom free from stones including removing out the excavated soil/ material as directed. (i) All kinds of Soil (1.1*0.45*60)
34.65
468
16216.2
laying of HT/LT UG cables by trenchless technology by adopting horizontal directional drilling (HDD Method). The work includes preparation of site, Boring as well as drawing of cable in Normal/Hard soil including soft, watery and sandy soil with minimum 8" bore size with HDPE pipe.
104
-
-
Back Filling of the available excavated earth (excluding rock) in trenches, plinth, sides, foundation etc. in layer work exceeding 0.2 mtr. depth consolidating each deposited layer by ramming and watering. (Excavation 151.35)-(sand 32.28)-(Cable 4.18)-(RCC cover 6.88)-(Bricks 34.5)(0.9*0.45*60)
28.35
120
3402
Laying of sand. (0.45*0.2*60)
6.3
-
-
Disposal of earth at a distance of 3000 mtrs
6.3
-
-
Erection, Testing and Commissioning of 11KV,3 core x 300 mm2 XLPE HT cable excluding cable end termination.
180
342
61560
Erection testing and commissioning of 11 Kv cable end termination kits indoor type suitable for: 3 core X 300 mm2 cable XLPE
1
2548
2548
Erection, testing and commissioning of heat shrinkable straight through jointing kit suitable for 3 C x 300 sq.mm XLPE cable
1
3713
3713
laying of underground cable protective cover as per specs. The concrete sla shall be machine madeusing semi dry concrete that is batched in afully automatic PLC controlled concrete batching plant and cast in a fully automatic "Vibra press"machine with high vibration frequency and hydraulic pressure of 40MT , size of the slab shall be 480 mm*250 mm*50 mm and the concrete grade shall be M 30vadhiring to IS 4561:2000 shall have a minimum crushing strength of 30 N/mm2( 28 days strength when tested
146
60
8760
Erection of RCC Hume Pipe 250 mm dia with required no. of collars, for road crossing.
10
254
2540
Erection of RCC cable Route marker (400x900x100 mm)
2
256
512
Laying in position cement concrete 1:2:4 (1 cement : 2 coarse sand: 4 graded granitic or basaltic stone aggregate 40 m nominal size for reinstatement.
9.54
-
-
Evaluation Notes How It Works ?