Electricity Department Tender
View complete overview of Goa Electricity Department Tender
Costs
EMD
₹ 23,435Document Cost
₹ 500Tender Fee
₹ 2,344
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2025_ED_20275_1Tender No
Tender 29(24-25)/DIV-VI DT 21/2/25Tender Authority
Electricity Department ViewPurchaser Address
-Website
http://eprocure.goa.gov.in
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
BOQ Items
... More
Enamelled Danger board 11000 Volts:
The plate should be made from mild steel at least 1.6mm thick and vitreous enamelled white with letters, figures and convectional skull and bones in signal red color on the front side. The rear side of the plate shall be enamelled. All lettering should be centrally spaced. The corners of the plates should be rounded off.
Size" 250mm x 200 mm. (as per drawing no. EE-II-3/2001, CEE/E/490)
4
248
992
... More
3 WAY RMU, 11KV, 630A, 21 kA 3Sec, SF6 Outdoor RMU – 2LBS + 1CB
Extensible/Non-Extensible Two (2) Motor operated load break switches (LBSs) with Manual operated earthing switches in SF6 and One (1) vacuum circuit breaker with Electrical closing and tripping along with disconnector and earthing switches SCADA Compatible and base channel. Battery charger along with batteries required for Electrical operations of RMU is in the scope of the Bidder. Each module shall consist of VPIS, FPI in LBS Module (N-1) but not less than 1 no’s per RMU. Suitable arrangement for mounting FRTU, modem or Ethernet Switch/LIU along with battery, battery charger shall be provided in RMU.
1
620750
620750
... More
Pinth for 100KVA Transformer
-
-
-
... More
Providing and laying in position cement concrete 1:2:4 (1 cement : 2 coarse sand: 4 graded granitic or basaltic stone aggregate 40 m) nominal size for foundations.
2.24
6635
14862.4
... More
Centering and shuttering including struttings, propping etc and removal of formwork .
14.25
407
5799.75
... More
12mm cement plaster 1:4 (1 - cement: 4 - fine sand) for foundations.
11.82
223
2635.86
... More
Brick work using common burnt clay building bricks in cement mortar 1:4 (1 - cement: 4 - coarse sand) in foundation and plinth (b) with bricks of class designation 75 Kgs/sq.cm (wire cut bricks).
1.4
8358
11701.2
... More
Supply, storage transportation to work site, laying termination, testing and commissioning of XLPE cable of voltage 11 KV 3 core 300 Sq.mm excluding cable end termination.( 2 Runs)
35
2595
90825
... More
Supply, storage transportation to work site, laying termination, testing and commissioning of XLPE cable of voltage 11 KV 3 core 95 Sq.mm excluding cable end termination.
20
1240
24800
... More
XLPE Indoor heat shrinkable Termination Kit suitable for 300 sq. mm , 11 KV XLPE cable
2
8840
17680
... More
HS. 11KV straight through joint 3 core 240 to 400 sqmm
2
29559
59118
... More
XLPE Indoor heat shrinkable Termination Kit suitable for 95 sq. mm , 11 KV XLPE cable
1
6731
6731
... More
XLPE Outdoor heat shrinkable Termination Kit suitable for 95 sq. mm , 11 KV XLPE cable
1
10152
10152
... More
Supply & laying of sand.
8.5
2170
18445
... More
PCC Precasst cable protective cover of size 480mmx250mmx50mm casted by confined mold vibratory cast of concrete mix m30 having strength of 30n/mm2 at 28 days
125
135
16875
... More
RCC Cable route marker (400 x 900 x 100mm) (as per CEE approved drawing)
2
528
1056
... More
Supply and spreading of 40/20mm basaltic or granitic stone aggregate in the switchyard
1.2
1212
1454.4
... More
GI Pipe 150mm, class B
12
1681
20172
... More
G.I. Nuts & Bolts 100x16mm
2.4
228
547.2
... More
GI flat 25x5mm
45
116
5220
... More
COST OF ERECTION
-
-
-
... More
100 KVA 11KV/0.4KV Distribution Transformers level II losses, Alluminium Winding, with Bimetallic Terminal Connectors, Energy Efficiency Level-II as per IS: 1180 (Part-I): 2014
1
11017
11017
... More
Supply and laying of unarmoured single core 300sqmm XLPE 1.1 KV grade to be laid from transformer to Distribution Box
44
218
9592
... More
XLPE cable armoured 3 ½ C X 185 sq.mm 1.1 KV Grade
30
228
6840
... More
Aluminium Crimping lug 300 sq.mm
8
101
808
... More
Aluminium Crimping lug 95 sq.mm
2
65
130
... More
Aluminium Crimping lug 185 sq.mm
6
95
570
... More
Distribution Boxes (M.S) with 200Amps MCCB & Kit-Kat fuses for 100KVA Distribution Transformers.
As per drawing No.CEE/E-689 Revision No.3 alongwith 12 nos. of 200A Kitkat Porcelain fuse carrier and base with extended terminals conforming in general to drawing No.EE-II/7/2002 with 1 no. moulded case circuit breaker (MCCB), 415V, AC, 50Hz with extended terminals conforming to IS 13947-2 as amended upto date.
1
4687
4687
... More
Distribution Transformer Metering Unit
1
1072
1072
... More
FRP Fencing complete with Gate as per specification for Distribution Transformer (Size 3Mx3Mx2M) with Concreting for FRP Fencing supports with plinth (0.3x0.3x0.5) Cu.m. x 12 nos. Each ratio 1:3:6
1
33667
33667
... More
Enamelled Danger board 11000 Volts:
The plate should be made from mild steel at least 1.6mm thick and vitreous enamelled white with letters, figures and convectional skull and bones in signal red color on the front side. The rear side of the plate shall be enamelled. All lettering should be centrally spaced. The corners of the plates should be rounded off.
Size" 250mm x 200 mm. (as per drawing no. EE-II-3/2001, CEE/E/490)
4
57
228
... More
Earthing complete with 40mm GI Pipe, 2.5 mts long alongwith 20 kgs each salt, charcoal complete.
8
2444
19552
... More
3 WAY RMU, 11KV, 630A, 21 kA 3Sec, SF6 Outdoor RMU – 2LBS + 1CB
Extensible/Non-Extensible Two (2) Motor operated load break switches (LBSs) with Manual operated earthing switches in SF6 and One (1) vacuum circuit breaker with Electrical closing and tripping along with disconnector and earthing switches SCADA Compatible and base channel. Battery charger along with batteries required for Electrical operations of RMU is in the scope of the Bidder. Each module shall consist of VPIS, FPI in LBS Module (N-1) but not less than 1 no’s per RMU. Suitable arrangement for mounting FRTU, modem or Ethernet Switch/LIU along with battery, battery charger shall be provided in RMU.
1
9720
9720
... More
Earthwork excavation in foundations trenches (not exceeding 1.5mts in width or 10mm² on plan) including opening of roads, chamber/pavements & soiling , ramming, levelling of bottoms, making free from stones including removing out the excavated soil/material as directed within a lead of 40mts in laterite rock soil (1.1X 0.6 X 90)
38
468
17784
... More
Supply, storage transportation to work site, laying termination, testing and commissioning of XLPE cable of voltage 11 KV 3 core 300 Sq.mm excluding cable end termination.( 2 Runs)
35
342
11970
... More
Supply, storage transportation to work site, laying termination, testing and commissioning of XLPE cable of voltage 11 KV 3 core 95 Sq.mm excluding cable end termination.
20
199
3980
... More
XLPE Indoor heat shrinkable Termination Kit suitable for 300 sq. mm , 11 KV XLPE cable
2
2548
5096
... More
HS. 11KV straight through joint 3 core 240 to 400 sqmm
2
3713
7426
... More
XLPE Indoor heat shrinkable Termination Kit suitable for 95 sq. mm , 11 KV XLPE cable
1
2538
2538
... More
XLPE Outdoor heat shrinkable Termination Kit suitable for 95 sq. mm , 11 KV XLPE cable
1
2648
2648
... More
Back Filling up of available excavated earth (excluding rock/stones) in trenches, plinth, sides, foundations etc. in layer not exceeding 0.2 mtrs. depth consolidation each deposited layer by ramming and watering (1 x 0.4 x 90)
15
120
1800
... More
Disposal of surplus excavated soil/material by mechanical transportation including loading, unloading, starting leveling as directed up to a distance of 2.5 km
9.5
125
1195.29
... More
PCC Precasst cable protective cover of size 480mmx250mmx50mm casted by confined mold vibratory cast of concrete mix m30 having strength of 30n/mm2 at 28 days
125
60
7500
... More
RCC Cable route marker (400 x 900 x 100mm) (as per CEE approved drawing)
2
256
512
... More
GI Pipe 150mm, class B
12
182
2184
... More
G.I. Nuts & Bolts 100x16mm
2.4
30
72
... More
GI flat 25x5mm
45
48
2160
Evaluation Notes How It Works ?
Potential Partner
Select Your Requirements
Past BiddersThis list is curated from the bidders of the similar tenders in the past
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%