Electricity Department Tender
View complete overview of Goa Electricity Department Tender
Costs
EMD
₹ 10,964Document Cost
₹ 500Tender Fee
₹ 1,096
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2024_ED_16425_1Tender No
Tender-09/Div-V (2024-25)Tender Authority
Electricity Department ViewPurchaser Address
-Website
http://eprocure.goa.gov.in
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
BOQ Items
LT/11KV Stay set complete 9 Mts long RCC pole
2
8733
4366.54
HDG L.T. 4 pin cross arm Channel type as above with HDG clamps & HDG nut bolts etc for 11mts long RCC pole as per drg No.CEE/E-491 and drg no. CEE/E-524
1
1614
1614.2
HDG L.T. 2 pin cross arm Channel type as above with HDG clamps & HDG nut bolts etc for 11 mts long RCC pole as per drg No.CEE/E-491 and drg no. CEE/E-524
1
1074
1074.2
HDG L.T. 4 pin cross arm Channel type as above with HDG clamps & HDG nut bolts etc for 9 mts long RCC pole as per drg No.CEE/E-491 and drg no. CEE/E-524
3
4398
1466.2
HDG L.T. 2 pin cross arm Channel type as above with HDG clamps & HDG nut bolts etc for 9 mts long RCC pole as per drg No.CEE/E-491 and drg no. CEE/E-524
3
2778
926.2
LT brown glazed shackle Insulator of size 100 mm x 115 mm conforming to fig No. 4 and type 2 fo IS: 1445/77 as amended upto date. Minimum failing load shall be 16 KN with GI hardware suitable for LT shackle insulator of size 100 x 115 mm conforming to type 2 fig 4 of IS: 1445/77 as amended upto date. Hardware or fitting shall conform to fig 4 of IS: 7935-1975 as amended upto date comprise fo 2 GI strips, 2 GI bolts and 2 nuts with spring washers.
15
5580
372
Earthing complete with chamber as per drg/ No. CEE/E-830. Each earthing should consist as follows a) 40 mm. Dia 2.5 mtr long, class B GI pipe 1 No. b)HDGI nut bolts, clamps 1 set, c)Brick masonary-0.108 Cu.mts d) PVC pipe 50mm dia- 0.2mtr e) Salt-20 Kgs f) Charcoal-20 Kgs g) Excavation-0.864 Cu. Mtr h) refilling-0.74 Cu.mtr as per drg. No.CEE/E-830.
6
16380
2730
XPLE insulated single core unarmoured cable 50 mm2 for DP earthing.
55
4565
83
AA"ANT" conductor
0.7
33660
48086
AA"GNAT" conductor
0.7
17705
25293
AA"WEASEL" conductor
0.3
10022
33409
XLPE 1.1KV Armored single core unarmoured cable 300 mm²
48
22896
477
XLPE 1.1KV 3 & 1/2 XLPE Armoured cable 120 mm²
48
43824
913
Enamelled danger boards 11000 Volts ,250mm x 200mmm as per drg no. CEE/E-490
2
496
248
Painting of Pole Numbers
2
208
104.33
FRP Fencing complete with Gate as epr specification for distribution transformer (size 4Mx3Mx2M) with Concreting for FRP Fencing supports with plinth (0.3x0.3x0.5)Cu.m.x12nos Each ratio 1;3;6
1
76667
76667
DTC metering unit
1
25688
25688
4g modem
1
6000
6000
Cost of Erection
-
-
-
Supply & Erection of RCC pole 9 mtr as per the drawing No.CEE/E-724 REV-3 as per annexure confirming to IS 785-1998 as amended upto date. The component used for pole shall conform to following IS amended up to date. 1) Ordinary Port land cement 53 grade IS 12269 2) Aggregate IS 383-1970 3) Torsteel IS 1786-7985 4) MS bar IS 432 p 1 & 2-1982
2
11800
5900
11 KV rated voltange GOAB switches tilting type, outdoor, manually operated, triple pole, single break, conforming to IS: 9921-Part 1 to V as amended up to date and detailed specification eclosed herewith. Each set shall comprise of six pedestal and three tilting post insulators. Insulator should be factory cemented by the manufacturer of the insulators and have minimum 320 mm creepage distance and AB switchs contacts shall be of copper/ copper alloy. The AB switch shall be of following current rating: 200 A
1
3971
3971
11 KV , 200 A Horn gap fuse unit (Set of three) shall be as per enclosed drg No. CEE/E-786. Revision 3 and detailed specifications enclosed herewith.
1
3368
3368
9 KV, 5 KA nominal discharge current metal oxide gapless distribution class Lightning arrestor conforming to IEC-600994-4 and IS: 3070 part 3 1993 as amended upto date suitable for 11 KV 50 HZ effectively earthed neutral system with necessary mounting arragements and connector suitable to connect ASCR conductor upto overall diameter 12.30 mm
3
522
174
HDGI structure material for 12 DPS. Each trasformer centre DP consist of HDGI structure material as follows: a) GI channel ISMC 75x40x7.3mm 2.75 mtrs long 2 pieces for incoming line & installation of disc insulators b) GI channel ISMC75x40x7.3mm 2.75mtrs long 2 pieces for GOAB switch c) GI channel ISMC 75x40x7.3mm 2.75 mtrs long 2 pieces for HG fuses d) GI channel ISMC 75x40x7.3mm 2.75 mtrs long 2 pieces for installation of lightening arrestor e) GI channel ISMC 100x50x7.3mm 2.75 mtrs long 2 pieces for installation of Trasformer f) GI channel ISMC 75x40x7.3mm 2.75 mtrs long 2 pieces for side support of trasformer g) GI channel ISMC 75x40x7.3mm 2.75 mtrs long 4 pieces for installation of any other items h) GI channel ISMC 100x40x7.3mm 0.52 mtrs long 2 pieces for installation of Transformer base channel
260
12220
47
Supply & Erection of 200KVA 11KV/.4KV Distribution transformer level II Aluminium Winding with Bimetetllic terminal connectors energey effeiecny II as per IS 1180 ( Part-I):2014
1
15638
15638
Supply & erection of LT/11KV Stay set complete 11Mts long RCC pole
2
5072
2536.34
Supply & erection of LT/11KV Stay set complete 9 Mts long RCC pole
2
4931
2465.88
HDG L.T. 4 pin cross arm Channel type as above with HDG clamps & HDG nut bolts etc for 11mts long RCC pole as per drg No.CEE/E-491 and drg no. CEE/E-524
1
338
338
HDG L.T. 2 pin cross arm Channel type as above with HDG clamps & HDG nut bolts etc for 11 mts long RCC pole as per drg No.CEE/E-491 and drg no. CEE/E-524
1
309
309
HDG L.T. 4 pin cross arm Channel type as above with HDG clamps & HDG nut bolts etc for 9 mts long RCC pole as per drg No.CEE/E-491 and drg no. CEE/E-524
3
954
318
HDG L.T. 2 pin cross arm Channel type as above with HDG clamps & HDG nut bolts etc for 9 mts long RCC pole as per drg No.CEE/E-491 and drg no. CEE/E-524
3
867
289
LT brown glazed shackle Insulator of size 100 mm x 115 mm conforming to fig No. 4 and type 2 fo IS: 1445/77 as amended upto date. Minimum failing load shall be 16 KN with GI hardware suitable for LT shackle insulator of size 100 x 115 mm conforming to type 2 fig 4 of IS: 1445/77 as amended upto date. Hardware or fitting shall conform to fig 4 of IS: 7935-1975 as amended upto date comprise fo 2 GI strips, 2 GI bolts and 2 nuts with spring washers.
15
3120
208
Earthing complete with chamber as per drg/ No. CEE/E-830. Each earthing should consist as follows a) 40 mm. Dia 2.5 mtr long, class B GI pipe 1 No. b)HDGI nut bolts, clamps 1 set, c)Brick masonary-0.108 Cu.mts d) PVC pipe 50mm dia- 0.2mtr e) Salt-20 Kgs f) Charcoal-20 Kgs g) Excavation-0.864 Cu. Mtr h) refilling-0.74 Cu.mtr as per drg. No.CEE/E-830.
6
14664
2444
XPLE insulated single core unarmoured cable 50 mm2 for DP earthing.
55
3080
56
Supply & Stringing of AA"ANT" conductor
0.7
7210
10300
Supply & Stringing AA"GNAT" conductor
0.7
6370
9100
Supply & Stringing AA"WEASEL" conductor
0.3
3300
11000
MS Distribution box as per drg No. CEE/E-689 Revision No. 3 along with MCCB 400 A, Bus bar made out of Aluminium strips 40 x 10 mm, kit kat fuses for 4 feeder arrangement
1
8795
8795
XLPE 1.1KV Armored single core unarmoured cable 300 mm²
48
10464
218
XLPE 1.1KV 3 & 1/2 XLPE Armoured cable 120 mm²
48
8448
176
Enamelled danger boards 11000 Volts ,250mm x 200mmm as per drg no. CEE/E-490
2
114
57
Aluminium crimping Lugs shall conform to IS: 8309-1976 as amended upto date. Lugs shall be made of aluminium of grade IE of IS: 5082/1969 suitable for aluminium cable fo sizes 300 Sq.mm.
8
808
101
Aluminium crimping Lugs shall conform to IS: 8309-1976 as amended upto date. Lugs shall be made of aluminium of grade IE of IS: 5082/1969 suitable for aluminium cable fo sizes 120 Sq.mm.
9
792
88
Aluminium crimping Lugs shall conform to IS: 8309-1976 as amended upto date. Lugs shall be made of aluminium of grade IE of IS: 5082/1969 suitable for aluminium cable fo sizes 95 Sq.mm.
4
260
65
Aluminium crimping Lugs shall conform to IS: 8309-1976 as amended upto date. Lugs shall be made of aluminium of grade IE of IS: 5082/1969 suitable for aluminium cable fo sizes50 Sq.mm.
55
2805
51
Cement concreting 1 : 2:4 for base of MS box & muffing of raile poles
2
11110
5555
Painting of Pole Numbers
2
-
-
Removing of FRP Box
1
1500
1500
Removing of 11KV GOAB switch 200 A, 3 Pole DP AB Switch
1
1985
1985.5
Removing of 11KV 200 A H.G Fuse unit
1
1684
1684
Removing of HDGI structural material
260
6110
23.5
Removing of 150KVA Transformer
1
7819
7819
Removing & Re-stringing of AA ANT Conductor
0.46
7107
15450
Removing & Re-Stringing of AA GNAT Conductor
0.46
6279
13650
Removing of XLPE 1.1KV 3 & 1/2 c cable 120 sq. mm²
12
1056
88
Removing of XLPE 1.1KV 3 & 1/2 c cable 95sq. mm²
24
1788
74.5
Supply & Erection of FRP Fencing complete with Gate as epr specification for distribution transformer (size 4Mx3Mx2M) with Concreting for FRP Fencing supports with plinth (0.3x0.3x0.5)Cu.m.x12nos Each ratio 1;3;6
1
35000
35000
Supply & Erection of DTC metering unit
1
1072
1072
Supply & Erection of 4g modem
1
-
-
Evaluation Notes How It Works ?
Potential Partner
Select Your Requirements