Electricity Department Tender

View complete overview of Goa Electricity Department Tender

Electricity Department Tender

Works
Electrical and Electronics
Electrical Works
Eprocure
Opening Date16 Dec 2024
Closing Soon2 Jan 2025
Tender Amount₹ 17,18,762 
Notes
Download

Costs

  • EMD

    ₹ 34,375
  • Document Cost

    ₹ 500
  • Tender Fee

    ₹ 3,438

Summary

Work Of Enhancement Of 100kva Maruti Dtc To 200kva At Madhalamaz Mandrem, 100kva Bhumika Dtc To 200kva At Ashvem Mandrem And 100kva Reliance Dtc To 200kva At Bhomwada Palyem To Release Electricity Connection Under So Mandrem,sd Iii Agrawdada

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
DTC Metering

1

25688

25688

... More
FRP Fencing complete with Gate as per specification for Distribution Transformer (Size 4Mx3Mx2M) with Concreting for FRP Fencing supports with plinth (0.3x0.3x0.5) Cu.m. x 12 nos. Each ratio 1:3:6

1

76667

76667

... More
COST OF ERECTION

-

-

-

... More
Supply, transportation, hoisting, erection, testing and commissioning of 200KVA, 11kv/0.4kv Distribution Transformer, level II losses, Aluminium wounding with bimetalic terminal connector, Enenry efficiency level II as per IS:1180(Part-I):2014

1

15638

15638

... More
Supply and erection, testing and commisioning of MS Distribution Box along with 12 Nos 200 A kit kat fuse and MCCB odf 400A, 415 Volts. The box shall be fabricated with MS sheet 12 gauge with overlaping rain proof slit ventilators on both side of the distiburion box with wire mash to prevent enty of insects with pin head door hinges locking arrangements and shall have require no of bus bar made out of alluminium stripa 40x 6 mm, other & accessories.

1

8795

8795

... More
Supply and laying of unarmoured 1core 300 sqmm XLPE power cable (1run per phase & 1run for neutral) (12 mtrs per phase)

48

218

10464

... More
Supply and laying of unarmoured 1core 185 sqmm XLPE power cable (1run per phase & 1run for neutral) (12 mtrs per phase)(3 feeders)

144

170

24480

... More
AAC ANT conductor

0.72

6634

4776.48

... More
AAC Gnat conductor

0.72

6183

4451.76

... More
HDG LT 4 pin cross arm channel type HDG clamps & HDG nut bolts etc for 7.5 Mts long RCC pole

4

305

1220

... More
HDG LT 2 pin cross arm channel type HDG clamps & HDG nut bolts etc for 7.5 Mts long RCC pole

4

276

1104

... More
Supply & erection of LT Shackle insulator with metal part

20

208

4160

... More
Supply & erection of LT Pin insulator with Metal parts

20

173

3460

... More
DTC Metering

1

1072

1072

... More
Removing of Aluminium wound 100KVA Distribution Transformer. Star rating, 11kv/0.4kv, Enenry level II as per IS:1180(Part-I):2014

1

5508

5508.5

... More
Removing of 200A deteriorated MS Distribution Box

1

2343

2343.5

... More
Removing of XLPE 3 1/2 Core armoured XLPE 185 sq mm 1.1 KV grade(3nos feeder, 12Mtsx3 nos)

36

114

4104

... More
Removing of XLPE 3 1/2 Core armoured XLPE 240 sq mm 1.1 KV grade

12

136

1632

... More
Removing of deteriorated AAC ANT conductor

0.72

3317

2388.24

... More
Removing of deteriorated AAC Gnat conductor

0.72

3091

2225.88

... More
Removing of deteriorated of HDG LT 4 pin cross arm channel type HDG clamps & HDG nut bolts etc for 7.5 Mts long RCC pole

4

152

610

... More
Removing of deteriorated of HDG LT 2 pin cross arm channel type HDG clamps & HDG nut bolts etc for 7.5 Mts long RCC pole

4

138

552

... More
Removing of deteriorated of LT Shackle insulator with metal part

20

104

2080

... More
Removing of deteriorated of LT Pin insulator with Metal parts

20

86

1730

... More
Removing of non working DTC Metering

1

536

536

... More
Erection of FRP Fencing complete with Gate as per specification for Distribution Transformer (Size 4Mx3Mx2M) with Concreting for FRP Fencing supports with plinth (0.3x0.3x0.5) Cu.m. x 12 nos. Each ratio 1:3:6

1

35000

35000

... More
Supply and erection of G.I earthing pipe 2500mm long, 40mm dia class B fabricated and perforated filled with homogenous mixture of 20Kgs of salt and sand / soil inclusive of excavation, backfilling & spreading of excavated earth evenly as per Drg No. CEE/E-829. The work includes excavation of pit in any type of soil classified under Soft Strata of Annexure A of CPWD-8.

6

2444

14664

... More
Work2:- The work of enhancement of 100 KVA Bhumika DTC to 200KVA DTC at Ashvem Mandrem in order to release electricity connection to Mrs Melanie D Britto for the total load of 36.47KW under section office Mandrem, Sub Div III Agarwada, Div XVII, Mapusa.

-

-

-

... More
COST OF MATERIAL

-

-

-

... More
Supply, transportation, hoisting, erection, testing and commissioning of 200KVA, 11kv/0.4kv Distribution Transformer, level II losses, Aluminium wounding with bimetalic terminal connector, Enenry efficiency level II as per IS:1180(Part-I):2014

1

377405

377405

... More
DTC Metering

1

25688

25688

... More
COST OF ERECTION

-

-

-

... More
Supply, transportation, hoisting, erection, testing and commissioning of 200KVA, 11kv/0.4kv Distribution Transformer, level II losses, Aluminium wounding with bimetalic terminal connector, Enenry efficiency level II as per IS:1180(Part-I):2014

1

15638

15638

... More
Supply and erection, testing and commisioning of MS Distribution Box along with 12 Nos 200 A kit kat fuse and MCCB odf 400A, 415 Volts.

1

8795

8795

... More
Supply and laying of unarmoured 1core 300 sqmm XLPE power cable (1run per phase & 1run for neutral) (12 mtrs per phase)

48

218

10464

... More
Supply and laying of unarmoured 1core 185 sqmm XLPE power cable (1run per phase & 1run for neutral) (12 mtrs per phase)(3 feeders)

144

170

24480

... More
DTC Metering

1

1072

1072

... More
Supply and erection of G.I earthing pipe 2500mm long, 40mm dia class B fabricated and perforated filled with homogenous mixture of 20Kgs of salt and sand / soil inclusive of excavation, backfilling & spreading of excavated earth evenly as per Drg No. CEE/E-829. The work includes excavation of pit in any type of soil classified under Soft Strata of Annexure A of CPWD-8.

4

2444

9776

... More
Removing of Aluminium wound 100KVA Distribution Transformer. Star rating, 11kv/0.4kv, Enenry level II as per IS:1180(Part-I):2014

1

5508

5508.5

... More
Removing of 200A deteriorated MS Distribution Box

1

2343

2343.5

... More
Removing of XLPE 3 1/2 Core armoured XLPE 185 sq mm 1.1 KV grade(3nos feeder, 12Mtsx3 nos)

36

114

4104

... More
Removing of XLPE 3 1/2 Core armoured XLPE 240 sq mm 1.1 KV grade

10

136

1360

... More
Removing of non working DTC Metering

1

536

536

... More
Work3:- The work of enhancement of 100 KVA Reliance DTC to 200KVA DTC at Bhomwada Palyem in order to release electricity connection to Mr Pranjna Pradlhad Naik for the total load of 32.70KW under section office Mandrem, Sub Div III Agarwada, Div XVII, Mapusa.

-

-

-

... More
COST OF MATERIAL

-

-

-

... More
Supply, transportation, hoisting, erection, testing and commissioning of 200KVA, 11kv/0.4kv Distribution Transformer, level II losses, Aluminium wounding with bimetalic terminal connector, Enenry efficiency level II as per IS:1180(Part-I):2014

1

377405

377405

... More
DTC Metering

1

25688

25688

... More
FRP Fencing complete with Gate as per specification for Distribution Transformer (Size 4Mx3Mx2M) with Concreting for FRP Fencing supports with plinth (0.3x0.3x0.5) Cu.m. x 12 nos. Each ratio 1:3:6

1

76667

76667

... More
COST OF ERECTION

-

-

-

... More
Supply, transportation, hoisting, erection, testing and commissioning of 200KVA, 11kv/0.4kv Distribution Transformer, level II losses, Aluminium wounding with bimetalic terminal connector, Enenry efficiency level II as per IS:1180(Part-I):2014

1

15638

15638

... More
Supply and erection, testing and commisioning of MS Distribution Box along with 12 Nos 200 A kit kat fuse and MCCB odf 400A, 415 Volts. The box shall be fabricated with MS sheet 12 gauge with overlaping rain proof slit ventilators on both side of the distiburion box with wire mash to prevent enty of insects with pin head door hinges locking arrangements and shall have require no of bus bar made out of alluminium stripa 40x 6 mm, other & accessories.

1

8795

8795

... More
Supply and laying of unarmoured 1core 300 sqmm XLPE power cable (1run per phase & 1run for neutral) (12 mtrs per phase)

48

218

10464

... More
Supply and laying of unarmoured 1core 185 sqmm XLPE power cable (1run per phase & 1run for neutral) (12 mtrs per phase)(3 feeders)

144

170

24480

... More
DTC Metering

1

1072

1072

... More
MODEM as per MRT specification

1

-

-

... More
Erection of FRP Fencing complete with Gate as per specification for Distribution Transformer (Size 4Mx3Mx2M) with Concreting for FRP Fencing supports with plinth (0.3x0.3x0.5) Cu.m. x 12 nos. Each ratio 1:3:6

1

35000

35000

... More
Supply and erection of G.I earthing pipe 2500mm long, 40mm dia class B fabricated and perforated filled with homogenous mixture of 20Kgs of salt and sand / soil inclusive of excavation, backfilling & spreading of excavated earth evenly as per Drg No. CEE/E-829. The work includes excavation of pit in any type of soil classified under Soft Strata of Annexure A of CPWD-8.

4

2444

9776

... More
Removing of Aluminium wound 100KVA Distribution Transformer. Star rating, 11kv/0.4kv, Enenry level II as per IS:1180(Part-I):2014

1

5508

5508.5

... More
Removing of 200A deteriorated MS Distribution Box

1

2343

2343.5

... More
Removing of XLPE 3 1/2 Core armoured XLPE 185 sq mm 1.1 KV grade(3nos feeder, 12Mtsx3 nos)

36

114

4104

... More
Removing of XLPE 3 1/2 Core armoured XLPE 240 sq mm 1.1 KV grade

10

136

1360

... More
Removing of non working DTC Metering

1

536

536



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements

Past Bidders
This list is curated from the bidders of the similar tenders in the past

Unlock the Tender details for free
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.