Electricity Department Tender

View complete overview of Goa Electricity Department Tender

Electricity Department Tender

Works
Electrical Generators And Transformers
Electrical and Electronics
Eprocure
Opening Date9 Jun 2023
Closing Date26 Jun 2023
Tender Amount₹ 13,06,83,842 
Notes
Download

Costs

  • EMD

    ₹ 23,06,838
  • Document Cost

    ₹ 1,500
  • Tender Fee

    ₹ 6,000

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
11KV 3 phase indoor terminating kit to be used with cables - 300sq.mm.

160

1208640

7554

... More
11KV 3 phase outdoor terminating kit including sockets at 11KV end of DT to be used with cables as per - 95sq.mm.

80

685920

8574

... More
FRP Fencing complete with Gate as per specification for Distribution Transformer (Size  4Mx3Mx2M) with Concreting for FRP Fencing supports with plinth (0.3x0.3x0.5) Cu.m. x 12 nos. Each ratio 1:3:6

80

4000000

50000

... More
200 KVA 11kv/.4kv Distribution Transformers level II losses, Alluminium Winding, with Bimetallic Terminal Connectors, Energy Efficiency Level-II as per IS: 1180 (Part-I): 2014

80

20000000

250000

... More
1 core, 150sq.mm, Al conductor XLPE insulated 1.1KV grade unarmoured power cable (from transformer to LV distribution board) (4 runs)

3200

428800

134

... More
Outdoor, LV Main Switchboard for 200KVA Transformer centre made of FRP sheet with PU painted and complete with all accsesories and HDGI mounting channels.

80

18800000

235000

... More
Sand for cushioning of HT underground cables. (Dimesions : - 0.2*.45*22)

158.4

302860

1912

... More
Providing and laying in position cement concrete 1:2:4 (1 cement : 2 coarse sand: 4 graded granitic or basaltic stone aggregate 40 m nominal size for foundations. {Dimensions for LV Switch = 4*3.5*0.25 Transformer = 2.5*2.5*0.25}

405

2587140

6388

... More
Centering and shuttering including struttings, propping etc and removal of formwork . = Dimension of Cement Concrete * 8

3240

1127520

348

... More
12mm cement plaster 1:4 (1 - cement: 4 - fine sand) for foundations. Dimension for LV Switch = {(4*3.5)+(3.5*.25*2)+(4*.25*2)} Transformer = {(2.5*2.5)+(1.2*2.5*4)}

2880

486720

169

... More
Brick work using common burnt clay building bricks in cement mortar 1:4 (1 - cement: 4 - coarse sand) in foundation and plinth (b) with bricks of class designation 75 Kgs/sq.cm (wire cut bricks). Dimensions for Transformer = (2.5*2*4*.9)

1440

10679040

7416

... More
RCC Protactive Cover

1520

150480

99

... More
Earthing complete with 40mm GI Pipe, 2.5 mts long alongwith 20 kgs each salt, charcoal complete.

560

1528800

2730

... More
HDGI flat of size 25mm x 5mm for earthing.

2800

252000

90

... More
Erection

-

-

-

... More
11KV 3 phase indoor terminating kit to be used with cables - 300sq.mm.

160

468800

2930

... More
11KV 3 phase outdoor terminating kit including sockets at 11KV end of DT to be used with cables as per - 95sq.mm.

80

214720

2684

... More
FRP Fencing complete with Gate as per specification for Distribution Transformer (Size  4Mx3Mx2M) with Concreting for FRP Fencing supports with plinth (0.3x0.3x0.5) Cu.m. x 12 nos. Each ratio 1:3:6

80

400000

5000

... More
200 KVA 11kv/.4kv Distribution Transformers level II losses, Alluminium Winding, with Bimetallic Terminal Connectors, Energy Efficiency Level-II as per IS: 1180 (Part-I): 2014

80

800000

10000

... More
1 core, 150sq.mm, Al conductor XLPE insulated 1.1KV grade unarmoured power cable (from transformer to LV distribution board) (4 runs)

3200

326400

102

... More
Outdoor, LV Main Switchboard for 200KVA Transformer centre made of FRP sheet with PU painted and complete with all accsesories and HDGI mounting channels.

80

440000

5500

... More
Earthwork in excavation by mechanical means (hydraulic excavator)/manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sq.m on plan) including disposal of excavated earth lead upto 50 m and lift upto 1.5m disposed earth to be leveled and neatly dressed including providing barricading, danger lighting guarding as directed in : Hard Soil (Dimensions : - 1.1*.45*22)

871.2

407721

468

... More
Refilling the pipeline/foundation trenches plinth sides, foundation etc. with available excavated earth in layers not exceeding 20 cm depth consolidating each layer ramming and watering lead upto 50 M and all lifts and disposal of surplus earth as directed by Engineer in Charge (Dimesions : - 0.9*.45*22)

712.8

41342

58

... More
Earthing complete with 40mm GI Pipe, 2.5 mts long alongwith 20 kgs each salt, charcoal complete.

560

322000

575

... More
HDGI flat of size 25mm x 5mm for earthing.

2800

14000

5

... More
Dismentalling with all equipment

80

2827520

35344

... More
Estimate - 1b - Replacement of Old/Frayed Distribution Transformer to 400kVA Transformer along with LV Panel including Civil Work

-

-

-

... More
Supply

-

-

-

... More
11KV 3 phase indoor terminating kit to be used with cables - 300sq.mm.

10

75540

7554

... More
11KV 3 phase outdoor terminating kit including sockets at 11KV end of DT to be used with cables as per - 95sq.mm.

5

42870

8574

... More
FRP Fencing complete with Gate as per specification for Distribution Transformer (Size  4Mx3Mx2M) with Concreting for FRP Fencing supports with plinth (0.3x0.3x0.5) Cu.m. x 12 nos. Each ratio 1:3:6

5

250000

50000

... More
400 KVA 11kv/.4kv Distribution Transformers level II losses, Copper Winding, with Bimetallic Terminal Connectors, Energy Efficiency Level-II as per IS: 1180 (Part-I): 2014

5

3250000

650000

... More
1 core, 150sq.mm, Al conductor XLPE insulated 1.1KV grade unarmoured power cable (from transformer to LV distribution board) (4 runs)

350

46900

134

... More
Outdoor, LV Main Switchboard for 400KVA Transformer centre made of FRP sheet with PU painted and complete with all accsesories and HDGI mounting channels.

5

1275000

255000

... More
Sand for cushioning of HT underground cables. (Dimesions : - 0.2*.45*22)

9.9

18928

1912

... More
Providing and laying in position cement concrete 1:2:4 (1 cement : 2 coarse sand: 4 graded granitic or basaltic stone aggregate 40 m nominal size for foundations. {Dimensions for LV Switch = 4*3.5*0.25 Transformer = 2.5*2.5*0.25}

25.31

161680

6388

... More
Centering and shuttering including struttings, propping etc and removal of formwork . = Dimension of Cement Concrete * 8

202.5

70470

348

... More
12mm cement plaster 1:4 (1 - cement: 4 - fine sand) for foundations. Dimension for LV Switch = {(4*3.5)+(3.5*.25*2)+(4*.25*2)} Transformer = {(2.5*2.5)+(1.2*2.5*4)}

180

30420

169

... More
Brick work using common burnt clay building bricks in cement mortar 1:4 (1 - cement: 4 - coarse sand) in foundation and plinth (b) with bricks of class designation 75 Kgs/sq.cm (wire cut bricks). Dimensions for Transformer = (2.5*2*4*.9)

90

667440

7416

... More
RCC Protactive Cover

95

9405

99

... More
Earthing complete with 40mm GI Pipe, 2.5 mts long alongwith 20 kgs each salt, charcoal complete.

35

95550

2730

... More
HDGI flat of size 25mm x 5mm for earthing.

175

15750

90

... More
Erection

-

-

-

... More
11KV 3 phase indoor terminating kit to be used with cables - 300sq.mm.

10

29300

2930

... More
11KV 3 phase outdoor terminating kit including sockets at 11KV end of DT to be used with cables as per - 95sq.mm.

5

13420

2684

... More
FRP Fencing complete with Gate as per specification for Distribution Transformer (Size  4Mx3Mx2M) with Concreting for FRP Fencing supports with plinth (0.3x0.3x0.5) Cu.m. x 12 nos. Each ratio 1:3:6

5

25000

5000

... More
400 KVA 11kv/.4kv Distribution Transformers level II losses, Copper Winding, with Bimetallic Terminal Connectors, Energy Efficiency Level-II as per IS: 1180 (Part-I): 2014

5

50000

10000

... More
1 core, 150sq.mm, Al conductor XLPE insulated 1.1KV grade unarmoured power cable (from transformer to LV distribution board) (4 runs)

350

35700

102

... More
Outdoor, LV Main Switchboard for 400KVA Transformer centre made of FRP sheet with PU painted and complete with all accsesories and HDGI mounting channels.

5

27500

5500

... More
Earthwork in excavation by mechanical means (hydraulic excavator)/manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sq.m on plan) including disposal of excavated earth lead upto 50 m and lift upto 1.5m disposed earth to be leveled and neatly dressed including providing barricading, danger lighting guarding as directed in : Hard Soil (Dimensions : - 1.1*.45*22)

54.45

25482

468

... More
Refilling the pipeline/foundation trenches plinth sides, foundation etc. with available excavated earth in layers not exceeding 20 cm depth consolidating each layer ramming and watering lead upto 50 M and all lifts and disposal of surplus earth as directed by Engineer in Charge (Dimesions : - 0.9*.45*22)

44.55

2583

58

... More
Earthing complete with 40mm GI Pipe, 2.5 mts long alongwith 20 kgs each salt, charcoal complete.

35

20125

575

... More
HDGI flat of size 25mm x 5mm for earthing.

175

875

5

... More
Dismentalling with all equipment

5

176720

35344

... More
Estimate - 1c - Replacement of Old/Frayed Distribution Transformer to 630kVA Transformer along with LV Panel including Civil Work

-

-

-

... More
Supply

-

-

-

... More
11KV 3 phase indoor terminating kit to be used with cables - 300sq.mm.

8

60432

7554

... More
11KV 3 phase outdoor terminating kit including sockets at 11KV end of DT to be used with cables as per - 95sq.mm.

4

34296

8574

... More
FRP Fencing complete with Gate as per specification for Distribution Transformer (Size  4Mx3Mx2M) with Concreting for FRP Fencing supports with plinth (0.3x0.3x0.5) Cu.m. x 12 nos. Each ratio 1:3:6

4

200000

50000

... More
630 KVA 11kv/.4kv Distribution Transformers level II losses, Copper Winding, with Bimetallic Terminal Connectors, Energy Efficiency Level-II as per IS: 1180 (Part-I): 2014

4

3600000

900000

... More
1 core, 150sq.mm, Al conductor XLPE insulated 1.1KV grade unarmoured power cable (from transformer to LV distribution board) (4 runs)

440

58960

134

... More
Outdoor, LV Main Switchboard for 630KVA Transformer centre made of FRP sheet with PU painted and complete with all accsesories and HDGI mounting channels.

4

1100000

275000

... More
Sand for cushioning of HT underground cables. (Dimesions : - 0.2*.45*22)

7.92

15143

1912

... More
Providing and laying in position cement concrete 1:2:4 (1 cement : 2 coarse sand: 4 graded granitic or basaltic stone aggregate 40 m nominal size for foundations. {Dimensions for LV Switch = 4*3.5*0.25 Transformer = 2.5*2.5*0.25}

20.25

129357

6388

... More
Centering and shuttering including struttings, propping etc and removal of formwork . = Dimension of Cement Concrete * 8

162

56376

348

... More
12mm cement plaster 1:4 (1 - cement: 4 - fine sand) for foundations. Dimension for LV Switch = {(4*3.5)+(3.5*.25*2)+(4*.25*2)} Transformer = {(2.5*2.5)+(1.2*2.5*4)}

144

24336

169

... More
Brick work using common burnt clay building bricks in cement mortar 1:4 (1 - cement: 4 - coarse sand) in foundation and plinth (b) with bricks of class designation 75 Kgs/sq.cm (wire cut bricks). Dimensions for Transformer = (2.5*2*4*.9)

72

533952

7416

... More
RCC Protactive Cover

76

7524

99

... More
Earthing complete with 40mm GI Pipe, 2.5 mts long alongwith 20 kgs each salt, charcoal complete.

28

76440

2730

... More
HDGI flat of size 25mm x 5mm for earthing.

140

12600

90

... More
Erection

-

-

-

... More
11KV 3 phase indoor terminating kit to be used with cables - 300sq.mm.

8

23440

2930

... More
11KV 3 phase outdoor terminating kit including sockets at 11KV end of DT to be used with cables as per - 95sq.mm.

4

10736

2684

... More
FRP Fencing complete with Gate as per specification for Distribution Transformer (Size  4Mx3Mx2M) with Concreting for FRP Fencing supports with plinth (0.3x0.3x0.5) Cu.m. x 12 nos. Each ratio 1:3:6

4

20000

5000

... More
630 KVA 11kv/.4kv Distribution Transformers level II losses, Copper Winding, with Bimetallic Terminal Connectors, Energy Efficiency Level-II as per IS: 1180 (Part-I): 2014

4

40000

10000

... More
1 core, 150sq.mm, Al conductor XLPE insulated 1.1KV grade unarmoured power cable (from transformer to LV distribution board) (4 runs)

440

44880

102

... More
Outdoor, LV Main Switchboard for 630KVA Transformer centre made of FRP sheet with PU painted and complete with all accsesories and HDGI mounting channels.

4

22000

5500

... More
Earthwork in excavation by mechanical means (hydraulic excavator)/manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sq.m on plan) including disposal of excavated earth lead upto 50 m and lift upto 1.5m disposed earth to be leveled and neatly dressed including providing barricading, danger lighting guarding as directed in : Hard Soil (Dimensions : - 1.1*.45*22)

43.56

20386

468

... More
Refilling the pipeline/foundation trenches plinth sides, foundation etc. with available excavated earth in layers not exceeding 20 cm depth consolidating each layer ramming and watering lead upto 50 M and all lifts and disposal of surplus earth as directed by Engineer in Charge (Dimesions : - 0.9*.45*22)

35.64

2067

58

... More
Earthing complete with 40mm GI Pipe, 2.5 mts long alongwith 20 kgs each salt, charcoal complete.

28

16100

575

... More
HDGI flat of size 25mm x 5mm for earthing.

140

700

5

... More
Dismentalling with all equipment

4

141376

35344

... More
Estimate - 2 - New Transformer along with LV Panel including Civil Work

-

-

-

... More
Supply

-

-

-

... More
11KV 3 phase indoor terminating kit to be used with cables - 300sq.mm.

10

75540

7554

... More
11KV 3 phase outdoor terminating kit including sockets at 11KV end of DT to be used with cables as per - 95sq.mm.

5

42870

8574

... More
FRP Fencing complete with Gate as per specification for Distribution Transformer (Size  4Mx3Mx2M) with Concreting for FRP Fencing supports with plinth (0.3x0.3x0.5) Cu.m. x 12 nos. Each ratio 1:3:6

5

250000

50000

... More
200 KVA 11kv/.4kv Distribution Transformers level II losses, Alluminium Winding, with Bimetallic Terminal Connectors, Energy Efficiency Level-II as per IS: 1180 (Part-I): 2014

5

1250000

250000

... More
1 core, 150sq.mm, Al conductor XLPE insulated 1.1KV grade unarmoured power cable (from transformer to LV distribution board) (4 runs)

200

26800

134

... More
Outdoor, LV Main Switchboard for 200KVA Transformer centre made of FRP sheet with PU painted and complete with all accsesories and HDGI mounting channels.

5

1175000

235000

... More
Sand for cushioning of HT underground cables. (Dimesions : - 0.2*.45*22)

9.9

18928

1912

... More
Providing and laying in position cement concrete 1:2:4 (1 cement : 2 coarse sand: 4 graded granitic or basaltic stone aggregate 40 m nominal size for foundations. {Dimensions for LV Switch = 4*3.5*0.25 Transformer = 2.5*2.5*0.25}

25.31

161680

6388

... More
Centering and shuttering including struttings, propping etc and removal of formwork . = Dimension of Cement Concrete * 8

202.5

70470

348

... More
12mm cement plaster 1:4 (1 - cement: 4 - fine sand) for foundations. Dimension for LV Switch = {(4*3.5)+(3.5*.25*2)+(4*.25*2)} Transformer = {(2.5*2.5)+(1.2*2.5*4)}

180

30420

169

... More
Brick work using common burnt clay building bricks in cement mortar 1:4 (1 - cement: 4 - coarse sand) in foundation and plinth (b) with bricks of class designation 75 Kgs/sq.cm (wire cut bricks). Dimensions for Transformer = (2.5*2*4*.9)

90

667440

7416

... More
RCC Protactive Cover

95

9405

99

... More
Earthing complete with 40mm GI Pipe, 2.5 mts long alongwith 20 kgs each salt, charcoal complete.

35

95550

2730

... More
HDGI flat of size 25mm x 5mm for earthing.

175

15750

90

... More
Erection

-

-

-

... More
11KV 3 phase indoor terminating kit to be used with cables - 300sq.mm.

10

29300

2930

... More
11KV 3 phase outdoor terminating kit including sockets at 11KV end of DT to be used with cables as per - 95sq.mm.

5

13420

2684

... More
FRP Fencing complete with Gate as per specification for Distribution Transformer (Size  4Mx3Mx2M) with Concreting for FRP Fencing supports with plinth (0.3x0.3x0.5) Cu.m. x 12 nos. Each ratio 1:3:6

5

25000

5000

... More
200 KVA 11kv/.4kv Distribution Transformers level II losses, Alluminium Winding, with Bimetallic Terminal Connectors, Energy Efficiency Level-II as per IS: 1180 (Part-I): 2014

5

50000

10000

... More
1 core, 150sq.mm, Al conductor XLPE insulated 1.1KV grade unarmoured power cable (from transformer to LV distribution board) (4 runs)

200

20400

102

... More
Outdoor, LV Main Switchboard for 200KVA Transformer centre made of FRP sheet with PU painted and complete with all accsesories and HDGI mounting channels.

5

27500

5500

... More
Earthwork in excavation by mechanical means (hydraulic excavator)/manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sq.m on plan) including disposal of excavated earth lead upto 50 m and lift upto 1.5m disposed earth to be leveled and neatly dressed including providing barricading, danger lighting guarding as directed in : Hard Soil (Dimensions : - 1.1*.45*22)

54.45

25482

468

... More
Refilling the pipeline/foundation trenches plinth sides, foundation etc. with available excavated earth in layers not exceeding 20 cm depth consolidating each layer ramming and watering lead upto 50 M and all lifts and disposal of surplus earth as directed by Engineer in Charge (Dimesions : - 0.9*.45*22)

44.55

2227

50

... More
Earthing complete with 40mm GI Pipe, 2.5 mts long alongwith 20 kgs each salt, charcoal complete.

35

20125

575

... More
HDGI flat of size 25mm x 5mm for earthing.

175

875

5

... More
Estimate - 2b - New 400kVA Transformer along with LV Panel including Civil Work

-

-

-

... More
Supply

-

-

-

... More
11KV 3 phase indoor terminating kit to be used with cables - 300sq.mm.

6

45324

7554

... More
11KV 3 phase outdoor terminating kit including sockets at 11KV end of DT to be used with cables as per - 95sq.mm.

3

25722

8574

... More
FRP Fencing complete with Gate as per specification for Distribution Transformer (Size  4Mx3Mx2M) with Concreting for FRP Fencing supports with plinth (0.3x0.3x0.5) Cu.m. x 12 nos. Each ratio 1:3:6

3

150000

50000

... More
400 KVA 11kv/.4kv Distribution Transformers level II losses, Copper Winding, with Bimetallic Terminal Connectors, Energy Efficiency Level-II as per IS: 1180 (Part-I): 2014

3

1950000

650000

... More
1 core, 150sq.mm, Al conductor XLPE insulated 1.1KV grade unarmoured power cable (from transformer to LV distribution board) (4 runs)

210

28140

134

... More
Outdoor, LV Main Switchboard for 400KVA Transformer centre made of FRP sheet with PU painted and complete with all accsesories and HDGI mounting channels.

3

765000

255000

... More
Sand for cushioning of HT underground cables. (Dimesions : - 0.2*.45*22)

5.94

11357

1912

... More
Providing and laying in position cement concrete 1:2:4 (1 cement : 2 coarse sand: 4 graded granitic or basaltic stone aggregate 40 m nominal size for foundations. {Dimensions for LV Switch = 4*3.5*0.25 Transformer = 2.5*2.5*0.25}

15.19

97033

6388

... More
Centering and shuttering including struttings, propping etc and removal of formwork . = Dimension of Cement Concrete * 8

121.5

42282

348

... More
12mm cement plaster 1:4 (1 - cement: 4 - fine sand) for foundations. Dimension for LV Switch = {(4*3.5)+(3.5*.25*2)+(4*.25*2)} Transformer = {(2.5*2.5)+(1.2*2.5*4)}

108

18252

169

... More
Brick work using common burnt clay building bricks in cement mortar 1:4 (1 - cement: 4 - coarse sand) in foundation and plinth (b) with bricks of class designation 75 Kgs/sq.cm (wire cut bricks). Dimensions for Transformer = (2.5*2*4*.9)

54

400464

7416

... More
RCC Protactive Cover

57

5643

99

... More
Earthing complete with 40mm GI Pipe, 2.5 mts long alongwith 20 kgs each salt, charcoal complete.

21

57330

2730

... More
HDGI flat of size 25mm x 5mm for earthing.

105

9450

90

... More
Erection

-

-

-

... More
11KV 3 phase indoor terminating kit to be used with cables - 300sq.mm.

6

17580

2930

... More
11KV 3 phase outdoor terminating kit including sockets at 11KV end of DT to be used with cables as per - 95sq.mm.

3

7944

2648

... More
FRP Fencing complete with Gate as per specification for Distribution Transformer (Size  4Mx3Mx2M) with Concreting for FRP Fencing supports with plinth (0.3x0.3x0.5) Cu.m. x 12 nos. Each ratio 1:3:6

3

15000

5000

... More
400 KVA 11kv/.4kv Distribution Transformers level II losses, Copper Winding, with Bimetallic Terminal Connectors, Energy Efficiency Level-II as per IS: 1180 (Part-I): 2014

3

30000

10000

... More
1 core, 150sq.mm, Al conductor XLPE insulated 1.1KV grade unarmoured power cable (from transformer to LV distribution board) (4 runs)

210

21420

102

... More
Outdoor, LV Main Switchboard for 400KVA Transformer centre made of FRP sheet with PU painted and complete with all accsesories and HDGI mounting channels.

3

16500

5500

... More
Earthwork in excavation by mechanical means (hydraulic excavator)/manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sq.m on plan) including disposal of excavated earth lead upto 50 m and lift upto 1.5m disposed earth to be leveled and neatly dressed including providing barricading, danger lighting guarding as directed in : Hard Soil (Dimensions : - 1.1*.45*22)

32.67

15289

468

... More
Refilling the pipeline/foundation trenches plinth sides, foundation etc. with available excavated earth in layers not exceeding 20 cm depth consolidating each layer ramming and watering lead upto 50 M and all lifts and disposal of surplus earth as directed by Engineer in Charge (Dimesions : - 0.9*.45*22)

26.73

1550

58

... More
Earthing complete with 40mm GI Pipe, 2.5 mts long alongwith 20 kgs each salt, charcoal complete.

21

12075

575

... More
HDGI flat of size 25mm x 5mm for earthing.

105

525

5

... More
Estimate - 2b - New 400kVA Transformer along with LV Panel including Civil Work

-

-

-

... More
Supply

-

-

-

... More
11KV 3 phase indoor terminating kit to be used with cables - 300sq.mm.

4

30216

7554

... More
11KV 3 phase outdoor terminating kit including sockets at 11KV end of DT to be used with cables as per - 95sq.mm.

2

17148

8574

... More
FRP Fencing complete with Gate as per specification for Distribution Transformer (Size  4Mx3Mx2M) with Concreting for FRP Fencing supports with plinth (0.3x0.3x0.5) Cu.m. x 12 nos. Each ratio 1:3:6

2

100000

50000

... More
630 KVA 11kv/.4kv Distribution Transformers level II losses, Copper Winding, with Bimetallic Terminal Connectors, Energy Efficiency Level-II as per IS: 1180 (Part-I): 2014

2

1800000

900000

... More
1 core, 150sq.mm, Al conductor XLPE insulated 1.1KV grade unarmoured power cable (from transformer to LV distribution board) (4 runs)

220

29480

134

... More
Outdoor, LV Main Switchboard for 630KVA Transformer centre made of FRP sheet with PU painted and complete with all accsesories and HDGI mounting channels.

2

550000

275000

... More
Sand for cushioning of HT underground cables. (Dimesions : - 0.2*.45*22)

3.96

7571

1912

... More
Providing and laying in position cement concrete 1:2:4 (1 cement : 2 coarse sand: 4 graded granitic or basaltic stone aggregate 40 m nominal size for foundations. {Dimensions for LV Switch = 4*3.5*0.25 Transformer = 2.5*2.5*0.25}

10.13

64710

6388

... More
Centering and shuttering including struttings, propping etc and removal of formwork . = Dimension of Cement Concrete * 8

81

28188

348

... More
12mm cement plaster 1:4 (1 - cement: 4 - fine sand) for foundations. Dimension for LV Switch = {(4*3.5)+(3.5*.25*2)+(4*.25*2)} Transformer = {(2.5*2.5)+(1.2*2.5*4)}

72

12168

169

... More
Brick work using common burnt clay building bricks in cement mortar 1:4 (1 - cement: 4 - coarse sand) in foundation and plinth (b) with bricks of class designation 75 Kgs/sq.cm (wire cut bricks). Dimensions for Transformer = (2.5*2*4*.9)

36

266976

7416

... More
RCC Protactive Cover

38

3762

99

... More
Earthing complete with 40mm GI Pipe, 2.5 mts long alongwith 20 kgs each salt, charcoal complete.

14

38220

2730

... More
HDGI flat of size 25mm x 5mm for earthing.

70

6300

90

... More
Erection

-

-

-

... More
11KV 3 phase indoor terminating kit to be used with cables - 300sq.mm.

4

11720

2930

... More
11KV 3 phase outdoor terminating kit including sockets at 11KV end of DT to be used with cables as per - 95sq.mm.

2

5296

2648

... More
FRP Fencing complete with Gate as per specification for Distribution Transformer (Size  4Mx3Mx2M) with Concreting for FRP Fencing supports with plinth (0.3x0.3x0.5) Cu.m. x 12 nos. Each ratio 1:3:6

2

10000

5000

... More
630 KVA 11kv/.4kv Distribution Transformers level II losses, Copper Winding, with Bimetallic Terminal Connectors, Energy Efficiency Level-II as per IS: 1180 (Part-I): 2014

2

20000

10000

... More
1 core, 150sq.mm, Al conductor XLPE insulated 1.1KV grade unarmoured power cable (from transformer to LV distribution board) (4 runs)

220

22440

102

... More
Outdoor, LV Main Switchboard for 630KVA Transformer centre made of FRP sheet with PU painted and complete with all accsesories and HDGI mounting channels.

2

11000

5500

... More
Earthwork in excavation by mechanical means (hydraulic excavator)/manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sq.m on plan) including disposal of excavated earth lead upto 50 m and lift upto 1.5m disposed earth to be leveled and neatly dressed including providing barricading, danger lighting guarding as directed in : Hard Soil (Dimensions : - 1.1*.45*22)

21.78

10193

468

... More
Refilling the pipeline/foundation trenches plinth sides, foundation etc. with available excavated earth in layers not exceeding 20 cm depth consolidating each layer ramming and watering lead upto 50 M and all lifts and disposal of surplus earth as directed by Engineer in Charge (Dimesions : - 0.9*.45*22)

17.82

1033

58

... More
Earthing complete with 40mm GI Pipe, 2.5 mts long alongwith 20 kgs each salt, charcoal complete.

14

8050

575

... More
HDGI flat of size 25mm x 5mm for earthing.

70

350

5

... More
Division XIV Verna South Circle

-

-

-

... More
Estimate - 1 - Replacement of Old/Frayed Distribution Transformer to New Transformer

-

-

-

... More
Supply

-

-

-

... More
11KV 3 phase indoor terminating kit to be used with cables - 300sq.mm.

8

60432

7554

... More
11KV 3 phase outdoor terminating kit including sockets at 11KV end of DT to be used with cables as per - 95sq.mm.

4

34296

8574

... More
FRP Fencing complete with Gate as per specification for Distribution Transformer (Size  4Mx3Mx2M) with Concreting for FRP Fencing supports with plinth (0.3x0.3x0.5) Cu.m. x 12 nos. Each ratio 1:3:6

4

200000

50000

... More
200 KVA 11kv/.4kv Distribution Transformers level II losses, Alluminium Winding, with Bimetallic Terminal Connectors, Energy Efficiency Level-II as per IS: 1180 (Part-I): 2014

4

1000000

250000

... More
1 core, 150sq.mm, Al conductor XLPE insulated 1.1KV grade unarmoured power cable (from transformer to LV distribution board) (4 runs)

160

21440

134

... More
Outdoor, LV Main Switchboard for 200KVA Transformer centre made of FRP sheet with PU painted and complete with all accsesories and HDGI mounting channels.

4

940000

235000

... More
Sand for cushioning of HT underground cables. (Dimesions : - 0.2*.45*22)

7.92

15143

1912

... More
Providing and laying in position cement concrete 1:2:4 (1 cement : 2 coarse sand: 4 graded granitic or basaltic stone aggregate 40 m nominal size for foundations. {Dimensions for LV Switch = 4*3.5*0.25 Transformer = 2.5*2.5*0.25}

20.25

129357

6388

... More
Centering and shuttering including struttings, propping etc and removal of formwork . = Dimension of Cement Concrete * 8

162

56376

348

... More
12mm cement plaster 1:4 (1 - cement: 4 - fine sand) for foundations. Dimension for LV Switch = {(4*3.5)+(3.5*.25*2)+(4*.25*2)} Transformer = {(2.5*2.5)+(1.2*2.5*4)}

144

24336

169

... More
Brick work using common burnt clay building bricks in cement mortar 1:4 (1 - cement: 4 - coarse sand) in foundation and plinth (b) with bricks of class designation 75 Kgs/sq.cm (wire cut bricks). Dimensions for Transformer = (2.5*2*4*.9)

72

533952

7416

... More
RCC Protactive Cover

76

7524

99

... More
Earthing complete with 40mm GI Pipe, 2.5 mts long alongwith 20 kgs each salt, charcoal complete.

28

76440

2730

... More
HDGI flat of size 25mm x 5mm for earthing.

140

12600

90

... More
Erection

-

-

-

... More
11KV 3 phase indoor terminating kit to be used with cables - 300sq.mm.

8

23440

2930

... More
11KV 3 phase outdoor terminating kit including sockets at 11KV end of DT to be used with cables as per - 95sq.mm.

4

10736

2684

... More
FRP Fencing complete with Gate as per specification for Distribution Transformer (Size  4Mx3Mx2M) with Concreting for FRP Fencing supports with plinth (0.3x0.3x0.5) Cu.m. x 12 nos. Each ratio 1:3:6

4

20000

5000

... More
200 KVA 11kv/.4kv Distribution Transformers level II losses, Alluminium Winding, with Bimetallic Terminal Connectors, Energy Efficiency Level-II as per IS: 1180 (Part-I): 2014

4

40000

10000

... More
1 core, 150sq.mm, Al conductor XLPE insulated 1.1KV grade unarmoured power cable (from transformer to LV distribution board) (4 runs)

160

16320

102

... More
Outdoor, LV Main Switchboard for 200KVA Transformer centre made of FRP sheet with PU painted and complete with all accsesories and HDGI mounting channels.

4

22000

5500

... More
Earthwork in excavation by mechanical means (hydraulic excavator)/manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sq.m on plan) including disposal of excavated earth lead upto 50 m and lift upto 1.5m disposed earth to be leveled and neatly dressed including providing barricading, danger lighting guarding as directed in : Hard Soil (Dimensions : - 1.1*.45*22)

43.56

20386

468

... More
Refilling the pipeline/foundation trenches plinth sides, foundation etc. with available excavated earth in layers not exceeding 20 cm depth consolidating each layer ramming and watering lead upto 50 M and all lifts and disposal of surplus earth as directed by Engineer in Charge (Dimesions : - 0.9*.45*22)

35.64

2067

58

... More
Earthing complete with 40mm GI Pipe, 2.5 mts long alongwith 20 kgs each salt, charcoal complete.

28

16100

575

... More
HDGI flat of size 25mm x 5mm for earthing.

140

700

5

... More
Dismentalling with all equipment

4

141376

35344

... More
Estimate - 1b - Replacement of Old/Frayed Distribution Transformer to 400kVA Transformer along with LV Panel including Civil Work

-

-

-

... More
Supply

-

-

-

... More
11KV 3 phase indoor terminating kit to be used with cables - 300sq.mm.

4

30216

7554

... More
11KV 3 phase outdoor terminating kit including sockets at 11KV end of DT to be used with cables as per - 95sq.mm.

2

17148

8574

... More
FRP Fencing complete with Gate as per specification for Distribution Transformer (Size  4Mx3Mx2M) with Concreting for FRP Fencing supports with plinth (0.3x0.3x0.5) Cu.m. x 12 nos. Each ratio 1:3:6

2

100000

50000

... More
400 KVA 11kv/.4kv Distribution Transformers level II losses, Copper Winding, with Bimetallic Terminal Connectors, Energy Efficiency Level-II as per IS: 1180 (Part-I): 2014

2

1300000

650000

... More
1 core, 150sq.mm, Al conductor XLPE insulated 1.1KV grade unarmoured power cable (from transformer to LV distribution board) (4 runs)

140

18760

134

... More
Outdoor, LV Main Switchboard for 400KVA Transformer centre made of FRP sheet with PU painted and complete with all accsesories and HDGI mounting channels.

2

510000

255000

... More
Sand for cushioning of HT underground cables. (Dimesions : - 0.2*.45*22)

3.96

7571

1912

... More
Providing and laying in position cement concrete 1:2:4 (1 cement : 2 coarse sand: 4 graded granitic or basaltic stone aggregate 40 m nominal size for foundations. {Dimensions for LV Switch = 4*3.5*0.25 Transformer = 2.5*2.5*0.25}

10.13

64710

6388

... More
Centering and shuttering including struttings, propping etc and removal of formwork . = Dimension of Cement Concrete * 8

81

28188

348

... More
12mm cement plaster 1:4 (1 - cement: 4 - fine sand) for foundations. Dimension for LV Switch = {(4*3.5)+(3.5*.25*2)+(4*.25*2)} Transformer = {(2.5*2.5)+(1.2*2.5*4)}

72

12168

169

... More
Brick work using common burnt clay building bricks in cement mortar 1:4 (1 - cement: 4 - coarse sand) in foundation and plinth (b) with bricks of class designation 75 Kgs/sq.cm (wire cut bricks). Dimensions for Transformer = (2.5*2*4*.9)

36

266976

7416

... More
RCC Protactive Cover

38

3762

99

... More
Earthing complete with 40mm GI Pipe, 2.5 mts long alongwith 20 kgs each salt, charcoal complete.

14

38220

2730

... More
HDGI flat of size 25mm x 5mm for earthing.

70

6300

90

... More
Erection

-

-

-

... More
11KV 3 phase indoor terminating kit to be used with cables - 300sq.mm.

4

11720

2930

... More
11KV 3 phase outdoor terminating kit including sockets at 11KV end of DT to be used with cables as per - 95sq.mm.

2

5368

2684

... More
FRP Fencing complete with Gate as per specification for Distribution Transformer (Size  4Mx3Mx2M) with Concreting for FRP Fencing supports with plinth (0.3x0.3x0.5) Cu.m. x 12 nos. Each ratio 1:3:6

2

10000

5000

... More
400 KVA 11kv/.4kv Distribution Transformers level II losses, Copper Winding, with Bimetallic Terminal Connectors, Energy Efficiency Level-II as per IS: 1180 (Part-I): 2014

2

20000

10000

... More
1 core, 150sq.mm, Al conductor XLPE insulated 1.1KV grade unarmoured power cable (from transformer to LV distribution board) (4 runs)

140

14280

102

... More
Outdoor, LV Main Switchboard for 400KVA Transformer centre made of FRP sheet with PU painted and complete with all accsesories and HDGI mounting channels.

2

11000

5500

... More
Earthwork in excavation by mechanical means (hydraulic excavator)/manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sq.m on plan) including disposal of excavated earth lead upto 50 m and lift upto 1.5m disposed earth to be leveled and neatly dressed including providing barricading, danger lighting guarding as directed in : Hard Soil (Dimensions : - 1.1*.45*22)

21.78

10193

468

... More
Refilling the pipeline/foundation trenches plinth sides, foundation etc. with available excavated earth in layers not exceeding 20 cm depth consolidating each layer ramming and watering lead upto 50 M and all lifts and disposal of surplus earth as directed by Engineer in Charge (Dimesions : - 0.9*.45*22)

17.82

1033

58

... More
Earthing complete with 40mm GI Pipe, 2.5 mts long alongwith 20 kgs each salt, charcoal complete.

14

8050

575

... More
HDGI flat of size 25mm x 5mm for earthing.

70

350

5

... More
Dismentalling with all equipment

2

70688

35344

... More
Estimate - 1c - Replacement of Old/Frayed Distribution Transformer to 630kVA Transformer along with LV Panel including Civil Work

-

-

-

... More
Supply

-

-

-

... More
11KV 3 phase indoor terminating kit to be used with cables - 300sq.mm.

4

30216

7554

... More
11KV 3 phase outdoor terminating kit including sockets at 11KV end of DT to be used with cables as per - 95sq.mm.

2

17148

8574

... More
FRP Fencing complete with Gate as per specification for Distribution Transformer (Size  4Mx3Mx2M) with Concreting for FRP Fencing supports with plinth (0.3x0.3x0.5) Cu.m. x 12 nos. Each ratio 1:3:6

2

100000

50000

... More
630 KVA 11kv/.4kv Distribution Transformers level II losses, Copper Winding, with Bimetallic Terminal Connectors, Energy Efficiency Level-II as per IS: 1180 (Part-I): 2014

2

1800000

900000

... More
1 core, 150sq.mm, Al conductor XLPE insulated 1.1KV grade unarmoured power cable (from transformer to LV distribution board) (4 runs)

220

29480

134

... More
Outdoor, LV Main Switchboard for 630KVA Transformer centre made of FRP sheet with PU painted and complete with all accsesories and HDGI mounting channels.

2

550000

275000

... More
Sand for cushioning of HT underground cables. (Dimesions : - 0.2*.45*22)

3.96

7571

1912

... More
Providing and laying in position cement concrete 1:2:4 (1 cement : 2 coarse sand: 4 graded granitic or basaltic stone aggregate 40 m nominal size for foundations. {Dimensions for LV Switch = 4*3.5*0.25 Transformer = 2.5*2.5*0.25}

10.13

64710

6388

... More
Centering and shuttering including struttings, propping etc and removal of formwork . = Dimension of Cement Concrete * 8

81

28188

348

... More
12mm cement plaster 1:4 (1 - cement: 4 - fine sand) for foundations. Dimension for LV Switch = {(4*3.5)+(3.5*.25*2)+(4*.25*2)} Transformer = {(2.5*2.5)+(1.2*2.5*4)}

72

12168

169

... More
Brick work using common burnt clay building bricks in cement mortar 1:4 (1 - cement: 4 - coarse sand) in foundation and plinth (b) with bricks of class designation 75 Kgs/sq.cm (wire cut bricks). Dimensions for Transformer = (2.5*2*4*.9)

36

266976

7416

... More
RCC Protactive Cover

38

3762

99

... More
Earthing complete with 40mm GI Pipe, 2.5 mts long alongwith 20 kgs each salt, charcoal complete.

14

38220

2730

... More
HDGI flat of size 25mm x 5mm for earthing.

70

6300

90

... More
Erection

-

-

-

... More
11KV 3 phase indoor terminating kit to be used with cables - 300sq.mm.

4

11720

2930

... More
11KV 3 phase outdoor terminating kit including sockets at 11KV end of DT to be used with cables as per - 95sq.mm.

2

5368

2684

... More
FRP Fencing complete with Gate as per specification for Distribution Transformer (Size  4Mx3Mx2M) with Concreting for FRP Fencing supports with plinth (0.3x0.3x0.5) Cu.m. x 12 nos. Each ratio 1:3:6

2

10000

5000

... More
630 KVA 11kv/.4kv Distribution Transformers level II losses, Copper Winding, with Bimetallic Terminal Connectors, Energy Efficiency Level-II as per IS: 1180 (Part-I): 2014

2

20000

10000

... More
1 core, 150sq.mm, Al conductor XLPE insulated 1.1KV grade unarmoured power cable (from transformer to LV distribution board) (4 runs)

220

22440

102

... More
Outdoor, LV Main Switchboard for 630KVA Transformer centre made of FRP sheet with PU painted and complete with all accsesories and HDGI mounting channels.

2

11000

5500

... More
Earthwork in excavation by mechanical means (hydraulic excavator)/manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sq.m on plan) including disposal of excavated earth lead upto 50 m and lift upto 1.5m disposed earth to be leveled and neatly dressed including providing barricading, danger lighting guarding as directed in : Hard Soil (Dimensions : - 1.1*.45*22)

21.78

10193

468

... More
Refilling the pipeline/foundation trenches plinth sides, foundation etc. with available excavated earth in layers not exceeding 20 cm depth consolidating each layer ramming and watering lead upto 50 M and all lifts and disposal of surplus earth as directed by Engineer in Charge (Dimesions : - 0.9*.45*22)

17.82

1033

58

... More
Earthing complete with 40mm GI Pipe, 2.5 mts long alongwith 20 kgs each salt, charcoal complete.

14

8050

575

... More
HDGI flat of size 25mm x 5mm for earthing.

70

350

5

... More
Dismentalling with all equipment

2

70688

35344

... More
Estimate - 2 - New Transformer along with LV Panel including Civil Work

-

-

-

... More
Supply

-

-

-

... More
11KV 3 phase indoor terminating kit to be used with cables - 300sq.mm.

12

90648

7554

... More
11KV 3 phase outdoor terminating kit including sockets at 11KV end of DT to be used with cables as per - 95sq.mm.

6

51444

8574

... More
FRP Fencing complete with Gate as per specification for Distribution Transformer (Size  4Mx3Mx2M) with Concreting for FRP Fencing supports with plinth (0.3x0.3x0.5) Cu.m. x 12 nos. Each ratio 1:3:6

6

300000

50000

... More
200 KVA 11kv/.4kv Distribution Transformers level II losses, Alluminium Winding, with Bimetallic Terminal Connectors, Energy Efficiency Level-II as per IS: 1180 (Part-I): 2014

6

1500000

250000

... More
1 core, 150sq.mm, Al conductor XLPE insulated 1.1KV grade unarmoured power cable (from transformer to LV distribution board) (4 runs)

240

32160

134

... More
Outdoor, LV Main Switchboard for 200KVA Transformer centre made of FRP sheet with PU painted and complete with all accsesories and HDGI mounting channels.

6

1410000

235000

... More
Sand for cushioning of HT underground cables. (Dimesions : - 0.2*.45*22)

11.88

22714

1912

... More
Providing and laying in position cement concrete 1:2:4 (1 cement : 2 coarse sand: 4 graded granitic or basaltic stone aggregate 40 m nominal size for foundations. {Dimensions for LV Switch = 4*3.5*0.25 Transformer = 2.5*2.5*0.25}

30.38

194067

6388

... More
Centering and shuttering including struttings, propping etc and removal of formwork . = Dimension of Cement Concrete * 8

243

84564

348

... More
12mm cement plaster 1:4 (1 - cement: 4 - fine sand) for foundations. Dimension for LV Switch = {(4*3.5)+(3.5*.25*2)+(4*.25*2)} Transformer = {(2.5*2.5)+(1.2*2.5*4)}

216

36504

169

... More
Brick work using common burnt clay building bricks in cement mortar 1:4 (1 - cement: 4 - coarse sand) in foundation and plinth (b) with bricks of class designation 75 Kgs/sq.cm (wire cut bricks). Dimensions for Transformer = (2.5*2*4*.9)

108

800928

7416

... More
RCC Protactive Cover

114

11286

99

... More
Earthing complete with 40mm GI Pipe, 2.5 mts long alongwith 20 kgs each salt, charcoal complete.

42

114660

2730

... More
HDGI flat of size 25mm x 5mm for earthing.

210

18900

90

... More
Erection

-

-

-

... More
11KV 3 phase indoor terminating kit to be used with cables - 300sq.mm.

12

35160

2930

... More
11KV 3 phase outdoor terminating kit including sockets at 11KV end of DT to be used with cables as per - 95sq.mm.

6

16104

2684

... More
FRP Fencing complete with Gate as per specification for Distribution Transformer (Size  4Mx3Mx2M) with Concreting for FRP Fencing supports with plinth (0.3x0.3x0.5) Cu.m. x 12 nos. Each ratio 1:3:6

6

30000

5000

... More
200 KVA 11kv/.4kv Distribution Transformers level II losses, Alluminium Winding, with Bimetallic Terminal Connectors, Energy Efficiency Level-II as per IS: 1180 (Part-I): 2014

6

60000

10000

... More
1 core, 150sq.mm, Al conductor XLPE insulated 1.1KV grade unarmoured power cable (from transformer to LV distribution board) (4 runs)

240

24480

102

... More
Outdoor, LV Main Switchboard for 200KVA Transformer centre made of FRP sheet with PU painted and complete with all accsesories and HDGI mounting channels.

6

33000

5500

... More
Earthwork in excavation by mechanical means (hydraulic excavator)/manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sq.m on plan) including disposal of excavated earth lead upto 50 m and lift upto 1.5m disposed earth to be leveled and neatly dressed including providing barricading, danger lighting guarding as directed in : Hard Soil (Dimensions : - 1.1*.45*22)

65.34

30579

468

... More
Refilling the pipeline/foundation trenches plinth sides, foundation etc. with available excavated earth in layers not exceeding 20 cm depth consolidating each layer ramming and watering lead upto 50 M and all lifts and disposal of surplus earth as directed by Engineer in Charge (Dimesions : - 0.9*.45*22)

53.46

2673

50

... More
Earthing complete with 40mm GI Pipe, 2.5 mts long alongwith 20 kgs each salt, charcoal complete.

42

24150

575

... More
HDGI flat of size 25mm x 5mm for earthing.

210

1050

5

... More
Estimate - 2b - New 400kVA Transformer along with LV Panel including Civil Work

-

-

-

... More
Supply

-

-

-

... More
11KV 3 phase indoor terminating kit to be used with cables - 300sq.mm.

2

15108

7554

... More
11KV 3 phase outdoor terminating kit including sockets at 11KV end of DT to be used with cables as per - 95sq.mm.

1

8574

8574

... More
FRP Fencing complete with Gate as per specification for Distribution Transformer (Size  4Mx3Mx2M) with Concreting for FRP Fencing supports with plinth (0.3x0.3x0.5) Cu.m. x 12 nos. Each ratio 1:3:6

1

50000

50000

... More
400 KVA 11kv/.4kv Distribution Transformers level II losses, Copper Winding, with Bimetallic Terminal Connectors, Energy Efficiency Level-II as per IS: 1180 (Part-I): 2014

1

650000

650000

... More
1 core, 150sq.mm, Al conductor XLPE insulated 1.1KV grade unarmoured power cable (from transformer to LV distribution board) (4 runs)

70

9380

134

... More
Outdoor, LV Main Switchboard for 400KVA Transformer centre made of FRP sheet with PU painted and complete with all accsesories and HDGI mounting channels.

1

255000

255000

... More
Sand for cushioning of HT underground cables. (Dimesions : - 0.2*.45*22)

1.98

3785

1912

... More
Providing and laying in position cement concrete 1:2:4 (1 cement : 2 coarse sand: 4 graded granitic or basaltic stone aggregate 40 m nominal size for foundations. {Dimensions for LV Switch = 4*3.5*0.25 Transformer = 2.5*2.5*0.25}

5.06

32323

6388

... More
Centering and shuttering including struttings, propping etc and removal of formwork . = Dimension of Cement Concrete * 8

40.5

14094

348

... More
12mm cement plaster 1:4 (1 - cement: 4 - fine sand) for foundations. Dimension for LV Switch = {(4*3.5)+(3.5*.25*2)+(4*.25*2)} Transformer = {(2.5*2.5)+(1.2*2.5*4)}

36

6084

169

... More
Brick work using common burnt clay building bricks in cement mortar 1:4 (1 - cement: 4 - coarse sand) in foundation and plinth (b) with bricks of class designation 75 Kgs/sq.cm (wire cut bricks). Dimensions for Transformer = (2.5*2*4*.9)

18

133488

7416

... More
RCC Protactive Cover

19

1881

99

... More
Earthing complete with 40mm GI Pipe, 2.5 mts long alongwith 20 kgs each salt, charcoal complete.

7

19110

2730

... More
HDGI flat of size 25mm x 5mm for earthing.

35

3150

90

... More
Erection

-

-

-

... More
11KV 3 phase indoor terminating kit to be used with cables - 300sq.mm.

2

5860

2930

... More
11KV 3 phase outdoor terminating kit including sockets at 11KV end of DT to be used with cables as per - 95sq.mm.

1

2648

2648

... More
FRP Fencing complete with Gate as per specification for Distribution Transformer (Size  4Mx3Mx2M) with Concreting for FRP Fencing supports with plinth (0.3x0.3x0.5) Cu.m. x 12 nos. Each ratio 1:3:6

1

5000

5000

... More
400 KVA 11kv/.4kv Distribution Transformers level II losses, Copper Winding, with Bimetallic Terminal Connectors, Energy Efficiency Level-II as per IS: 1180 (Part-I): 2014

1

10000

10000

... More
1 core, 150sq.mm, Al conductor XLPE insulated 1.1KV grade unarmoured power cable (from transformer to LV distribution board) (4 runs)

70

7140

102

... More
Outdoor, LV Main Switchboard for 400KVA Transformer centre made of FRP sheet with PU painted and complete with all accsesories and HDGI mounting channels.

1

5500

5500

... More
Earthwork in excavation by mechanical means (hydraulic excavator)/manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sq.m on plan) including disposal of excavated earth lead upto 50 m and lift upto 1.5m disposed earth to be leveled and neatly dressed including providing barricading, danger lighting guarding as directed in : Hard Soil (Dimensions : - 1.1*.45*22)

10.89

5096

468

... More
Refilling the pipeline/foundation trenches plinth sides, foundation etc. with available excavated earth in layers not exceeding 20 cm depth consolidating each layer ramming and watering lead upto 50 M and all lifts and disposal of surplus earth as directed by Engineer in Charge (Dimesions : - 0.9*.45*22)

8.91

516

58

... More
Earthing complete with 40mm GI Pipe, 2.5 mts long alongwith 20 kgs each salt, charcoal complete.

7

4025

575

... More
HDGI flat of size 25mm x 5mm for earthing.

35

175

5

... More
Estimate - 2c - New 630kVA Transformer along with LV Panel including Civil Work

-

-

-

... More
Supply

-

-

-

... More
11KV 3 phase indoor terminating kit to be used with cables - 300sq.mm.

2

15108

7554

... More
11KV 3 phase outdoor terminating kit including sockets at 11KV end of DT to be used with cables as per - 95sq.mm.

1

8574

8574

... More
FRP Fencing complete with Gate as per specification for Distribution Transformer (Size  4Mx3Mx2M) with Concreting for FRP Fencing supports with plinth (0.3x0.3x0.5) Cu.m. x 12 nos. Each ratio 1:3:6

1

50000

50000

... More
630 KVA 11kv/.4kv Distribution Transformers level II losses, Copper Winding, with Bimetallic Terminal Connectors, Energy Efficiency Level-II as per IS: 1180 (Part-I): 2014

1

900000

900000

... More
1 core, 150sq.mm, Al conductor XLPE insulated 1.1KV grade unarmoured power cable (from transformer to LV distribution board) (4 runs)

110

14740

134

... More
Outdoor, LV Main Switchboard for 630KVA Transformer centre made of FRP sheet with PU painted and complete with all accsesories and HDGI mounting channels.

1

275000

275000

... More
Sand for cushioning of HT underground cables. (Dimesions : - 0.2*.45*22)

1.98

3785

1912

... More
Providing and laying in position cement concrete 1:2:4 (1 cement : 2 coarse sand: 4 graded granitic or basaltic stone aggregate 40 m nominal size for foundations. {Dimensions for LV Switch = 4*3.5*0.25 Transformer = 2.5*2.5*0.25}

5.06

32323

6388

... More
Centering and shuttering including struttings, propping etc and removal of formwork . = Dimension of Cement Concrete * 8

40.5

14094

348

... More
12mm cement plaster 1:4 (1 - cement: 4 - fine sand) for foundations. Dimension for LV Switch = {(4*3.5)+(3.5*.25*2)+(4*.25*2)} Transformer = {(2.5*2.5)+(1.2*2.5*4)}

36

6084

169

... More
Brick work using common burnt clay building bricks in cement mortar 1:4 (1 - cement: 4 - coarse sand) in foundation and plinth (b) with bricks of class designation 75 Kgs/sq.cm (wire cut bricks). Dimensions for Transformer = (2.5*2*4*.9)

18

133488

7416

... More
RCC Protactive Cover

19

1881

99

... More
Earthing complete with 40mm GI Pipe, 2.5 mts long alongwith 20 kgs each salt, charcoal complete.

7

19110

2730

... More
HDGI flat of size 25mm x 5mm for earthing.

35

3150

90

... More
Erection

-

-

-

... More
11KV 3 phase indoor terminating kit to be used with cables - 300sq.mm.

2

5860

2930

... More
11KV 3 phase outdoor terminating kit including sockets at 11KV end of DT to be used with cables as per - 95sq.mm.

1

2648

2648

... More
FRP Fencing complete with Gate as per specification for Distribution Transformer (Size  4Mx3Mx2M) with Concreting for FRP Fencing supports with plinth (0.3x0.3x0.5) Cu.m. x 12 nos. Each ratio 1:3:6

1

5000

5000

... More
630 KVA 11kv/.4kv Distribution Transformers level II losses, Copper Winding, with Bimetallic Terminal Connectors, Energy Efficiency Level-II as per IS: 1180 (Part-I): 2014

1

10000

10000

... More
1 core, 150sq.mm, Al conductor XLPE insulated 1.1KV grade unarmoured power cable (from transformer to LV distribution board) (4 runs)

110

11220

102

... More
Outdoor, LV Main Switchboard for 630KVA Transformer centre made of FRP sheet with PU painted and complete with all accsesories and HDGI mounting channels.

1

5500

5500

... More
Earthwork in excavation by mechanical means (hydraulic excavator)/manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sq.m on plan) including disposal of excavated earth lead upto 50 m and lift upto 1.5m disposed earth to be leveled and neatly dressed including providing barricading, danger lighting guarding as directed in : Hard Soil (Dimensions : - 1.1*.45*22)

10.89

5096

468

... More
Refilling the pipeline/foundation trenches plinth sides, foundation etc. with available excavated earth in layers not exceeding 20 cm depth consolidating each layer ramming and watering lead upto 50 M and all lifts and disposal of surplus earth as directed by Engineer in Charge (Dimesions : - 0.9*.45*22)

8.91

516

58

... More
Earthing complete with 40mm GI Pipe, 2.5 mts long alongwith 20 kgs each salt, charcoal complete.

7

4025

575

... More
HDGI flat of size 25mm x 5mm for earthing.

35

175

5

... More
Estimate - 3 - SETC Work for 33KV Re-conductring from Existing Conductor to ACSR Wolf Conductor(Docuble Circuit Line) on 13 Mtr Rail Pole

-

-

-

... More
Supply

-

-

-

... More
Supply of Wolf ACSR conductor

98.88

10497199

106161

... More
For New Pole : -

-

-

-

... More
Supply of 13 mts Rail Pole 105 lb/yd for replacing damaged RCC pole/R.S. Joists

80

3531360

44142

... More
Painting of Rail poles, New & old(2Ltr)

80

37040

463

... More
Supply of Enamelled Danger board of size 250mm x 200 mm

80

11680

146

... More
Supply of Anti Climbing Device

80

76960

962

... More
Supply of Earthing complete with 40mm GI Pipe, 2.5 mts long along with Batonite complete with brick masonary Chamber

48

134400

2800

... More
GI Strip 25 x 5 mm

80

7200

90

... More
Hardware & Accessories

-

-

-

... More
Supply of G.I 33KV 'V' shaped X-arm made of 100 x 50 x 6 ISMC channel for Single Pole

128

136704

1068

... More
Supply of G.I 'V' shape X-arm clamp for 105 lb/yd pole with Nuts , Bolts & washers

256

93440

365

... More
Supply of G.I. Cutpoint Channel of 2.5mts long made of 100 x 50 x 6mm ISMC for Double Pole Structure with PG clamps for all Phase

80

216160

2702

... More
Supply of G.I. Cut point Channel Clamp for Single and Double Pole with Nuts , Bolts & washers

80

29200

365

... More
Supply of G.I. Cl packing pieces for Rail Pole 105 lb

208

35776

172

... More
Cross Bracing for Double Pole Stracture with Clamp (2mtr)

32

69184

2162

... More
33 KV pin insulators with pin

320

214080

669

... More
33 KV disc insulator (including metal parts)

352

724064

2057

... More
Supply of GI wire 7/10 SWG or guarding

1.6

168

105

... More
Supply of HDGI 50 x 50 Angle for guardning with clamps and nut bolt (1.5Mtr Long)

32

21536

673

... More
Supply of 33KV Stay set including nut Bolt and Insulator with civil work

80

59120

739

... More
Erection

-

-

-

... More
Supply of Wolf ACSR conductor

98.88

1362961

13784

... More
For New Pole : -

-

-

-

... More
Supply of 13 mts Rail Pole 105 lb/yd for replacing damaged RCC pole/R.S. Joists

80

1998880

24986

... More
Excavation of Pole Pit size : (450x450x2100) mm for 13 Mtr pole: for All type of Soil

34.08

15949

468

... More
Cement Concrete for new Poles

34.08

217703

6388

... More
13Mtr poles with Muffing

4.96

31684

6388

... More
Supply of Enamelled Danger board of size 250mm x 200 mm

80

3120

39

... More
Supply of Anti Climbing Device

80

11840

148

... More
Supply of Earthing complete with 40mm GI Pipe, 2.5 mts long along with Batonite complete with brick masonary Chamber

48

27600

575

... More
GI Strip 25 x 5 mm

80

400

5

... More
Hardware & Accessories

-

-

-

... More
Supply of G.I 33KV 'V' shaped X-arm made of 100 x 50 x 6 ISMC channel for Single Pole

128

37632

294

... More
Supply of G.I 'V' shape X-arm clamp for 105 lb/yd pole with Nuts , Bolts & washers

256

12800

50

... More
Supply of G.I. Cutpoint Channel of 2.5mts long made of 100 x 50 x 6mm ISMC for Double Pole Structure with PG clamps for all Phase

80

58640

733

... More
Supply of G.I. Cut point Channel Clamp for Single and Double Pole with Nuts , Bolts & washers

80

4000

50

... More
Supply of G.I. Cl packing pieces for Rail Pole 105 lb

208

8320

40

... More
Cross Bracing for Double Pole Stracture with Clamp (2mtr)

32

18752

586

... More
33 KV pin insulators with pin

320

69760

218

... More
33 KV disc insulator (including metal parts)

352

90816

258

... More
Supply of GI wire 7/10 SWG or guarding

1.6

123

77

... More
Supply of HDGI 50 x 50 Angle for guardning with clamps and nut bolt (1.5Mtr Long)

32

4992

156

... More
Supply of 33KV Stay set including nut Bolt and Insulator with civil work

80

123680

1546

... More
Removing of Existing 11 & 13 Mtr Rail Pole

80

238800

2985

... More
Removing of 33KV Pin insulators

320

34880

109

... More
Removing of Disc Insulators

352

38368

109

... More
Removing of Existing Conductor

96

1488096

15501



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.