Electricity Department Tender
View complete overview of Goa Electricity Department Tender
Costs
EMD
₹ 21,309Document Cost
₹ 1,500Tender Fee
₹ 2,131
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2024_ED_13210_1Bid Award Id
ViewTender No
Tender10(23-24)Tender Authority
Electricity Department ViewPurchaser Address
-Website
http://eprocure.goa.gov.in
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
BOQ Items
Supply of 11 KV HG fuse,200A, Horn gap type fuse
I.TECHNICAL PARTICULARS:
1. Highest System voltage : 12 KV (R.M.S)
2. Impulse voltage withstand voltage : 75 KV (Peak)
3. One minute power frequency withstand voltage : 35 KV (R.M.S.)
4. Continuous current rating of the unit : 200 Amps
5
52250
10450
Supply of 9 mts. long RCC poles .The poles should be as per drawing approved by CEE and conforming to IS standards as amended upto date. The Component used for pole shall conform to following IS amended upto date.
6
50316
8386
Supply of Stay set complete for 9.0 mts RCC Pole.HDGI Stay Sets Complete Comprising of stay rod with plate, HDGI stay wire of size 7/10swg, Break insulator of 15KV/8KV,HDGI turn buckle with eye bolt, suitable HDGI stay clamps, HDGI nut bolts, . The Stay wire shall comply with the specific requirements of IS: 2141-1979, IS: 4826-1979 & IS: 6594-1974 or the latest versions thereof and also as per the specifications enclosed.
6
26202
4367
Supplyof 9 KV, 5A Lightning Arrestor, pole mounted.9 KV, 5 KA nominal discharge current Metal Oxide gapless distribution class lightning arrestor conforming to IEC-60099-4 and IS 3070 Part 3 1993 as amended upto date suitable for 11 KV 50 HZ effectively earthed neutral system with necessary mounting arrangements and connector suitable to connect ACSR conductor upto overall diameter 12.30 mm.The marking of the Lightning Arrestors shall be as per IS
15
45495
3033
Supply of 11 KV Disc Insulators 45KN with H.D.G.I. Metal parts.11 KV disc insulators ball and socket type, type ‘A’ porcelain brown glazed duly cemented at factory with MCI socket cap, forged steel ball pin and supplied with Phosphor bronze “W” split pin as per IS 731-1971 as amended upto date. Pin ball diameter 16 mm. Minimum Creepage distance 320 mm. Ferrous parts shall be galvanized as per relevant IS
18
42570
2365
Providing of Cement concrete in the ratio 1:2:4(1 cement: 2 Sand, 4 graded granite/basaltic, aggregate 20mm nominal size) including cost of centering, shuttering & muffing 0.4mts above the ground & properly curved
4.8
26664
5555
Supply of ACSR 'WEASEL' of size ( 6/1/2.59mm) for earthing and jumpering .Packing and marking of drum will be as per IS:Conductor length shall be 1500 mtr. with tolerance of +/- 5%
0.5
16704
33409
Supply of meter boxes for trivector meter
3
17529
5843
Supply of Earthing complete with 2.5mts long, 40mm GI earthing pipe, class B, 20kgs each of salt and charcoal, excvation, re-filling etc.Earthing pipe made of Hot Dip galvanized steel tube of heavy class, 40mm nominal bore conforming to IS 1239 Part 1 1990 as amended upto date and Hot Dip zinc coating shall conform to IS 4736-1968 as amended upto date
26
70980
2730
Supply of Aluminum crimping lugs shall conform to IS: 8309-1976 as amended upto date. Lugs shall be made of aluminium of grade 1E of IS 5082-1969 suitable for aluminium cables of following sizes:
1. 70Sq.mm.
50
1700
34
Erection Cost
-
-
-
Providing of HDGI Structure Materials. shall be hot dipped galvanized
1235
58045
47
Erection of 11 KV GOAB switch with 200 A.12 KV rated voltage GOAB switches tilting type, outdoor, manually operated, triple pole, single break, conforming to IS: 9921-Part1 to V as amended upto date and detailed specifications enclosed herewith. Each set shall comprise of six pedestal and three tilting post insulators. Insulator should be factory cemented by the manufactures of the insulators and have minimum 320mm creepage distance and AB switches contacts shall be of copper/copper alloy
5
19855
3971
Fixing of 11 KV HG fuse,200A, Horn gap type fuse
I.TECHNICAL PARTICULARS:
1. Highest System voltage : 12 KV (R.M.S)
2. Impulse voltage withstand voltage : 75 KV (Peak)
3. One minute power frequency withstand voltage : 35 KV (R.M.S.)
4. Continuous current rating of the unit : 200 Amps
5
16840
3368
Erection of 9 mts. long RCC poles .The poles should be as per drawing approved by CEE and conforming to IS standards as amended upto date. The Component used for pole shall conform to following IS amended upto date.
6
26448
4408
Erection of Stay set complete for 9.0 mts RCC Pole.HDGI Stay Sets Complete Comprising of stay rod with plate, HDGI stay wire of size 7/10swg, Break insulator of 15KV/8KV,HDGI turn buckle with eye bolt, suitable HDGI stay clamps, HDGI nut bolts, conforming to drawings approved. The Stay wire shall comply with the specific requirements of IS: 2141-1979, IS: 4826-1979 & IS: 6594-1974 or the latest versions thereof and also as per the specifications enclosed.
6
14796
2466
Erection of 9 KV, 5A Lightning Arrestor, pole mounted.9 KV, 5 KA nominal discharge current Metal Oxide gapless distribution class lightning arrestor conforming to IEC-60099-4 and IS 3070 Part 3 1993 as amended upto date suitable for 11 KV 50 HZ effectively earthed neutral system with necessary mounting arrangements and connector suitable to connect ACSR conductor upto overall diameter 12.30 mm.The marking of the Lightning Arrestors shall be as per IS
15
2610
174
Supply of 11 KV Disc Insulators 45KN with H.D.G.I. Metal parts.11 KV disc insulators ball and socket type, type ‘A’ porcelain brown glazed duly cemented at factory with MCI socket cap, forged steel ball pin and supplied with Phosphor bronze “W” split pin as per IS 731-1971 as amended upto date. Pin ball diameter 16 mm. Minimum Creepage distance 320 mm. Ferrous parts shall be galvanized as per relevant IS
18
5976
332
Stringing of ACSR 'WEASEL' of size ( 6/1/2.59mm) for earthing and jumpering .Packing and marking of drum will be as per IS:Conductor length shall be 1500 mtr. with tolerance of +/- 5%
0.5
3555
7110
Fixing of meter boxes for trivector meter
3
4968
1656
Providing of Earthing complete with 2.5mts long, 40mm GI earthing pipe, class B, 20kgs each of salt and charcoal, excvation, re-filling etc.Earthing pipe made of Hot Dip galvanized steel tube of heavy class, 40mm nominal bore conforming to IS 1239 Part 1 1990 as amended upto date and Hot Dip zinc coating shall conform to IS 4736-1968 as amended upto date
26
63544
2444
Providing of Aluminum crimping lugs shall conform to IS: 8309-1976 as amended upto date. Lugs shall be made of aluminium of grade 1E of IS 5082-1969 suitable for aluminium cables of following sizes:
1. 70Sq.mm.
50
2950
59
Removal and refitting Of 11KV CTPT Unit of ratio 12.5/5A
3
16852
5617.5
Removal and refitting Of 11KV CTPT Unit of ratio 25/5A
1
5617
5617.5
Removal and refitting Of 11KV CTPT Unit of ratio 50/5A
1
5617
5617.5
Removal of HDGI Structural Materials
1235
29022
23.5
Removal of 11KV , 200A GOAB Switch unit
5
9927
1985.5
Removal of 200A HG Fuse unit
5
8420
1684
Removal of 9KV, 5KA Lightning Arrestor
15
1305
87
Removal of 45KN Disc Insulators with metal parts
30
4980
166
Removal of Weasel conductor
0.5
1777
3555
Removal of 9mtr RCC Poles
4
8816
2204
Removal of 90 Ib/yd 11 mtrs Rail Pole
2
21050
10525
Removal and reerection of meter box for trivector meter
1
2484
2484
Removal and Restringing of 11KV ABC Cable 3CX70 + 150Sqmm
0.05
3093
61876.5
Removal and restringing of Weasel conductor
0.22
2346
10665
Painting of transformer centre excluding transformer (Painting including scrapping of lod Paint, applying onne coat of primer (red oxide) and two coats of silver (aluminium) paint (RCC Pole DP). Including supply of required materials such as paint/primer etc.
3
22167
7389
Painting of Rail Poles 90 Ib/yd (Painting including scrapping of old paint, applying one coat of primer(red oxide) and two coats of silver (aluminium ) paint.(Including supply of required materials such as paint/primer etc).
19
15181
799
Painting of transformer centre excluding transformer (Painting including scrapping of lod Paint, applying onne coat of primer (red oxide) and two coats of silver (aluminium) paint (for Rail Pole DP). Including supply of required materials such as paint/primer etc.
1
10405
10405