Electricity Department Tender

View complete overview of Goa Electricity Department Tender

Electricity Department Tender

Works
Electrical Cables And Wires
Electrical Generators And Transformers
Electrical and Electronics
Eprocure
Opening Date20 Feb 2025
Closing Date11 Mar 2025
Tender Amount₹ 32,71,507 
Notes
Download

Costs

  • EMD

    ₹ 65,430
  • Document Cost

    ₹ 1,500
  • Tender Fee

    ₹ 6,000

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
Supply of HDGI top fitting 'x' arm channel (75 x 40mm) Supply & fixing of HDGI Top fitting cross arm ISMC channel,75x40mm,0.7mts long. The cross arms shall be fitted vertically onto the top end of the poles, at a height conforming to the relevant I.E. rules & utilizing suitable size of HDGI clamps & HDGI washers, HDGI nut bolts.

1

819

819

... More
Supply of 11KV Disc insulators 45KN with metal parts upply & fixing of 11kv Disc insulators with metal parts 45KN 11 KV disc insulators ball and socket type, type ‘A’ porcelain brown glazed duly cemented at factory with MCI socket cap, forged steel ball pin and supplied with Phosphor bronze “W” split pin as per IS 731-1971 as amended upto date. Minimum failing load. 45 KN.Pin ball diameter 16 mm. Minimum Creepage distance 320 mm. Ferrous parts shall be galvanized as per relevant IS. Insulator shall be marked as per IS. Acceptance tests and routine tests shall be carried out as per IS by the manufacturer and test results shall be furnished by the manufacturer before supply of materials.Department reserves the right to witness all the above tests. 3-bolted type hardware fitting suitable for 11KV ball and socket type disc insulators of 16mm pin, failing load of 45KN and suitable for ACSR WEASEL conductor. All iron parts should be hot dip galvanized as per IS:2629/1985 as amended upto date. Acceptance tests and routine tests shall be carried out by the manufacturer’s works and test reports shall be furnished before supply of materials. Department reserves the right to witness the above testing

3

2365

7095

... More
Supply of 11KV Pin insulators with G.I. pins LT pin insulator with HDGI pin The pin insulators shall be of sound, free from defects, thoroughly vitrified & smoothly glazed of brown color except for the screw threads & the parts on which the porcelain is supported. The insulator shall be in one piece. The pin insulator shall have a top groove & shall be threaded to take mild steel pins & shall conform to IS: 1445-1977. The pin shall be suitable for the minimum failing load of 3.5KN. The insula¬tor shall comply to the tests as per IS: 1445. The fittings shall be conf to IS: 7935-1975 or the latest version thereof & as per approved drawing. The ferrous pin, nuts & washers except those made of stainless steel shall be hot dipped galvanized. The threads of nuts shall be cut after galvanizing & shall be well oiled & greased. The pin shall have a stalk length of 135mm, shank length of 125mm & minimum failing load of 2.0 KN.

3

693

2079

... More
Supply of Stay sets complete for 9 mtr RCC pole . HDGI Stay Sets Complete Comprising of stay rod with plate, HDGI stay wire of size 7/10swg, Break insulator of 15KV/8KV,HDGI turn buckle with eye bolt, suitable HDGI stay clamps, HDGI nut bolts. The Stay wire shall comply with the specific requirements of IS: 2141-1979, IS: 4826-1979 & IS: 6594-1974 or the latest versions thereof. The wires shall be of tensile grade 4 & having minimum tensile strength of 700 N/mm2 conforming to IS: 2141. GI stay rod of 1800mm long and 16mm dia with an eye band of internal dia 40mm at one end and threaded up to length of 200mm at the other end galvanized. GI stay plate of 450x450x8mm size with a hole drilled at the centre to suit 16mm dia GI rod galvanized. GI stay wire standard of size 7/3.15mm (7/10SWG) wire should conform to ISS-2141/68 grade I and hot dipped galvanized as per IS 4826/1968 with up to date amendments. Two nos of GI square washer of size 40x40x6mm to suit the 16mm dia GI rod. Two nos of GI hexagonal nut and bolt suitable for threaded portion of the stay rod mentioned above and conforming to IS-1365/67 with amendment No-1. All the GI materials shall conform to IS-226/75 with amendment No- 1 to 3 tested quality. The breaking load shall be 63KN min proof load (40% of breaking load shall be performed on all the stay sets. Turn buckle with eye bolts for 11KV line & conforming to the following. One no of turn buckle made out of 16mm dia GI rod and 50x50x6mm M.S. angle galvanized. One eye bolt made out of 20mm dia GI rod with 40mm inner dia eye at one end threaded up to 300mm length from the other side. Two no’s GI nuts suitable for the threaded portion of eye bolt material specification IS-226/77 (tested quality) The breaking load and proof load shall be as per BS16/64 with amendment No-1. GI wire with tensile strength 32Kg/mm to 55Kg/mm soft quality 4.00mm dia 8SWG wire should conform to ISS-280/1972 and galvanized to heavy type as per ISS-4826/1968 with up to date amendments. The strain insulators shall be sound, free from defects, thoroughly vitrified & smoothly glazed & shall comply with the IS: 5300-1969 or the latest version thereof. The L.T. strain insulator shall have a minimum failing load of 44KN.

3

4367

13101

... More
Supply of HDGI nuts and bolts 100 X 16 mm HDGI nut & bolt The bolts and nuts shall be hot dip galvanized as per IS: 2629-1985 as amended upto date. Bolts and nuts shall be supplied in bags of 25 kgs each. The testing of galvanization of bolts and nuts shall be carried out by the manufacturer and test reports shall be furnished before supply of materials. Department reserves the right to witness above testing.

12

228

2736

... More
Supply and providing Cement concrete 1:2:4 Supply & Providing of Ordinary Portland Cement of grade 43 in HDPE bags of 50 KGs conforming to IS 8112.Cement should be filled in bags as per IS Specification. All bags should have ISI mark. The cement supplied shall be fresh and shall not be more than one month old from the date of manufacture. Cement concrete in the ratio 1:2:4(1 cement: 2 Sand, 4 graded granite/basaltic, aggregate 20mm nominal size) including cost of centering, shuttering & muffing 0.4mts above the ground & properly curved.

3.03

5555

16831.65

... More
Supply of Enamelled Danger boards for 11 KV Enamelled danger board 440Volts/ 11000 Volts /3300 Volts:The plate should be made from mild steel at least 1.6mm thick and vitreous enamelled whitewith letters,figures, and convectional skull and bones in singnal red colour on the front sidfe. The rear side of the plate shall be enamelled .All lettering should be centrally spaced the corners of the plate should be rounded offSizw "250mm x 200mm.

3

248

744

... More
Supply of Anti climbing devices with clamps(barbed wire) Hot dip galvanized steel barbed wire type 4 conforming to IS:278/1962 as amended upto date and galvanization conforming to IS:4826/1979as amended upto date. Nominal diameter of line wire and point wire shall be 2.24mm each. Nominal distance between the two barbs shall be 150mm. The weight of the each coil shall be 25 to 35 kg exclusive of weight of the reel.Tests as per IS shall be carried out at the manufacturer’s work & test reports shall be furnished before supply of materials. The department reserves the right to witness all the above tests.

6

145

870

... More
Supply of H.D.G.I. DP Structure materials M.S. Angle of size 50 x 50 x 6 mm of minimum tensile strength 410 MPa conforming to IS 2062 as amended upto date.The sectional weight of steel shall be 4.5kg/m.The length of each piece shall be 4.5m to 6m.The rolling and cutting tolerances for weight and dimensions of steel shall be as per IS 1852-1985.Tests as per IS shall be carried out at the manufacturers works and test reports shall be furnished before supply of materials. The Department reserves the right to witness all the above tests. M.S. Channel 100 X 50 MM ISMC of minimum tensile strength 410 MPa conforming to IS 2062 as amended up to date.The sectional weight of steel shall be 9.2kg/m for M.S. Channel 100x50x6 MM ISMC. The sectional weight of steel shall be 7.14kg/m for M.S. Channel 75x40x6 MM ISMC The length of each piece shall be 4.5m to 6m. The rolling and cutting tolerances for weight and dimensions of steel shall be as per IS 1852-1985. Tests as per IS shall be carried out at the manufacturers works and test reports shall be furnished before supply of materials. The Department reserves the right to witness all the above tests.

374

169

63206

... More
Supply of LA stay clamps for 9mt RCC pole All clamps & suitable nut bolts shall be hot dipped galvanized generally conforming to IS - 2633/72 & shall be conforming to the drawings and should be fitted with nut bolts.

11

491

5401

... More
Supply of SA stay clamps for 9mt RCC pole All clamps & suitable nut bolts shall be hot dipped galvanized generally conforming to IS - 2633/72 & shall be conforming to the drawings and should be fitted with nut bolts.

3

491

1473

... More
Supply of SA X arm clamps for 9mt RCC pole All clamps & suitable nut bolts shall be hot dipped galvanized generally conforming to IS - 2633/72 & shall be conforming to the drawings and should be fitted with nut bolts.

6

266

1596

... More
Supply of LA X arm clamps for 9mt RCC pole All clamps & suitable nut bolts shall be hot dipped galvanized generally conforming to IS - 2633/72 & shall be conforming to the drawings and should be fitted with nut bolts.

3

266

798

... More
Supply of G.I. 4 pin LT X arm channel type 75x40mm. The cross arms shall be fitted vertically onto the top end of the poles, at a height conforming to the relevant I.E. rules & utilizing suitable size of HDGI clamps & HDGI washers, HDGI nut bolts.

3

1109

3327

... More
Supply of G.I. 2 pin LT X arm channel type 75x40mm. The cross arms shall be fitted vertically onto the top end of the poles, at a height conforming to the relevant I.E. rules & utilizing suitable size of HDGI clamps & HDGI washers, HDGI nut bolts.

14

569

7966

... More
Supply of 11 KV GOAB switch 200A 12 KV rated voltage GOAB switches tilting type, outdoor, manually operated, triple pole, single break, conforming to IS: 9921-Part1 to V as amended upto date and detailed specifications enclosed herewith. Each set shall comprise of six pedestal and three tilting post insulators. Insulator should be factory cemented by the manufactures of the insulators and have minimum 320mm creepage distance and AB switches contacts shall be of copper/copper alloy. The AB switches shall be of 200 A current ratings:

2

23535

47070

... More
Supply of Earthing complete with 40mm G.I. pipe,2.5mts long alongwith 20kg each salt, charcoal complete. Supply & providing of Earthing with 40mm, 2.5 mm long GI pipe complete with chamber with brick masonary. Earthing pipe made of Hot Dip galvanized steel tube of heavy class, 40mm nominal bore conforming to IS 1239 Part 1 1990 as amended upto date and Hot Dip zinc coating shall conform to IS 4736-1968 as amended upto date

7

2730

19110

... More
Supply of ACSR Weasel conductor for earthing & jumpering Includes spreading of ACSR conductor without any damage and stringing with proper tension without any kinks/damage including binding of conductor at pin points, jumpering at cut points etc. The ground & line clearances at road crossings, along roads, Crossings & other crossings shall be as the relevant I.E. Rules. Tree cutting wherever required is to be carried out before stringing of the Conductor with prior permission of the Engineer in charge. The rates for Stringing of conductor in Schedule-II shall include cost of tree cutting as well.

0.15

33409

4844.31

... More
Supply of HG fuse unit 11 KV 200A 11 KV H. G. fuse unit shall be as per detailed specifications enclosed herewith Routine tests and acceptance for post insulators as per IS-2544-1973 as amended upto date and shall be carried out at the manufacturers works and test reports shall be furnished before supply of materials. The Department reserves the right to witness all the above tests.

2

10450

20900

... More
Supply of 9 KV 5 KA lightening arrestors 9 KV, 5 KA nominal discharge current Metal Oxide gapless distribution class lightning arrestor conforming to IEC-60099-4 and IS 3070 Part 3 1993 as amended upto date suitable for 11 KV 50 HZ effectively earthed neutral system with necessary mounting arrangements and connector suitable to connect ACSR conductor upto overall diameter 12.30 mm. The marking of the Lightning Arrestors shall be as per IS. The Acceptance tests and routine tests shall be carried out at the manufacturers works and test reports shall be furnished before supply of materials. The Department reserves the right to witness all the above tests.

6

3033

18198

... More
Supply of Distribution Box(MS) with 400A MCCB & kit kat fuses The MS distribution box shall be designed as per the general specifications . The same shall be manufactured and supplied only after the Executive Engineer has approved the design and after the Executive Engineer accepts sample. After acceptance of the sample the Distribution box shall be supplied & erected. The distribution box should be mounted vertically on the ground with proper foundation. The rate specified is inclusive of foundation work, etc. The Distribution box shall be provided with two doors & MCCB of 400A capacity and Kit Kat fuses with 200A ratings shall be provided. A separate compartment with a separate door with sealing arrangement, exclusively for energy meter shall be provided.

1

63140

63140

... More
Supply of DTC metering unit

1

25688

25688

... More
Supply of XLPE single core unarmoured cable 240sq.mm.1.1KV grade

40

366

14640

... More
Supply of XLPE single core unarmoured cable 120sq.mm.1.1KV grade(for feeders & Neutral)

80

164

13120

... More
Supply of Alluminium crimp lugs 240 sq. mm. Aluminium crimping lugs shall conform to IS:8309-1976 as amended upto date.Lugs shall be made of aluminium of grade 1E of IS 5082-1969 suitable for aluminium cables. Tests as per IS shall be carried out at manufacturers work and test reports shall be furnished before supply of materials.

8

94

752

... More
Supply of Alluminium crimp lugs 120 sq. mm. Aluminium crimping lugs shall conform to IS:8309-1976 as amended upto date.Lugs shall be made of aluminium of grade 1E of IS 5082-1969 suitable for aluminium cables .Tests as per IS shall be carried out at manufacturers work and test reports shall be furnished before supply of materials.

8

54

432

... More
Supply of Alluminium crimp lugs 70 sq. mm.( for Earthing and Jumpering ) Aluminium crimping lugs shall conform to IS:8309-1976 as amended upto date.Lugs shall be made of aluminium of grade 1E of IS 5082-1969 suitable for aluminium cables. Tests as per IS shall be carried out at manufacturers work and test reports shall be furnished before supply of materials.

23

34

782

... More
Supply of AA conductor ANT Includes spreading of AAC Conductors without any damage and stringing with proper tension without any kinks/damage including binding of conductor at pin points, jumpering at cut points, guard loops.. etc. The ground & line clearances at road crossings, along roads, L.T. crossings & other crossings shall be as the relevant I.E. rules. Tree cutting wherever required is to be carried out before stringing of the Conductor with prior permission of the Engineer in charge. The rates for Stringing of conductor in Schedule-II shall in¬clude cost of tree cutting as well. AAC Ant conductor for phases.

0.36

48086

17310.96

... More
Supply of AA conductor GNAT Includes spreading of AAC Conductors without any damage and stringing with proper tension without any kinks/damage including binding of conductor at pin points, jumpering at cut points, guard loops.. etc. The ground & line clearances at road crossings, along roads, L.T. crossings & other crossings shall be as the relevant I.E. rules. Tree cutting wherever required is to be carried out before stringing of the Conductor with prior permission of the Engineer in charge. The rates for Stringing of conductor in Schedule-II shall in¬clude cost of tree cutting as well. GNAT conductor for double neutral, & guard loops.

0.36

25293

9105.48

... More
Supply of LT 4 Pin cross arm channel type

2

1109

2218

... More
Supply of LT 2 Pin cross arm channel type

4

569

2276

... More
Supply of LT Shackle insulator with metal parts

15

372

5580

... More
Supply of FRP fencing complete with gate as per specification for distribution transformer(Size : 4MX3MX2M) with Concreting for FRP Fencing support with plinth (0.3x0.3x0.5) Cu.m x12 nos. Each ratio 1:3:6

1

76667

76667

... More
Supply & fixing of Modem for Automatic meter reading

1

6000

6000

... More
Supply of 11KV, 3 core, 300 sq.mm. aluminium, XLPE insulated, flat wire armoured, 11 KV (Earthed) Cable

484.5

2338

1132761

... More
Supply of 11KV, 3 core 185sq.mm aluminium, XLPE insulated, flat wire armoured, 11 KV (Earthed) Cable

32

1595

51040

... More
Supply of 3 WAY RMU ,11KV, 630 Amps,21 kA, 3 sec, SF6 Outdoor RMU- 2 LBS+ 1 CB Extension/Non-Extendable Two(2) Motor operated load break switches (LBS) with Manual operated earthing switches in SF6 and One (1) vaccum circuir breaker with electrical closing and tripping along with disonnector and earthing switches SCADA Compatible and basic channel. Battery charger along woth batetried required for electrical opearations of RMU is in the scope of bidder .Each module shall consisit of VPIS,FPIin LBS Module(N-1) but not less than 1 nos per RMU. Suitable arranegment for mounting FRTU, modem or Ethernet Switch/LIU along with baterry, battery charger shall be provided in RMU

1

565000

565000

... More
Supply of 11KV, 3 phase, Outdoor type, heat shrinkable end termination kit complete, for 11 KV XLPE cable of size 3 x 300sq.mm including sockets/lugs/connectors etc.

1

11667

11667

... More
Supply of 11KV, 3 phase, Indoor type, heat shrinkable end termination kit complete, for 11 KV XLPE cable of size 3 x 300 sq.mm including sockets/lugs/connectors etc. for connecting RMU for main section side.

1

8840

8840

... More
Supply of 11KV 3 phase outdoor terminating kit complete, for 11 KV XLPE cable of size 3 x 185 sq.mm including sockets/lugs/connectors etc. for connecting 11KV end of Distribution transformer .

1

10931

10931

... More
Supply of 11KV 3 phase indoor terminating kit complete, for 11 KV XLPE cable of size 3 x 185 sq.mm including sockets/lugs/connectors etc. for connecting RMU for main section side .

1

7873

7873

... More
Supply of straight through joint complete for 11 KV XLPE cable of size 3 x 300 sq.mm including sockets/lugs/connectors etc. .

2

29559

59118

... More
Supply of RCC Cable route Markers (400 x 900 x 100 mm)

5

528

2640

... More
Supply of Warning tape for entire 11 KV route length.

0.45

15000

6750

... More
Supplying and filling in plinth under floors, trenches including watering ramming consolidating, dressing , complete a) Sand

37.2

2170

80724

... More
Supply of vibro press RCC protective covers of size 480mm long x 250mm width and 50 mm thick capable of bearing load of 135 Kg. And covered with earth/sand upto depth of 0.15 mts. Conforming to IS 1255-1967 at non-road crossing

969

135

130815

... More
Supply of G.I. earthing pipe, 2500mm long, 40mm nominal dia, class B, perforated for RMU's The pit shall be filled with homogenous mixture of 20Kgs of Charcoal, 20Kgs of salt and sand /soil with Brick masonary Chambers The work includes excavation, backfilling & spreading of excavated surplace earth evenly at RMU's.

8

4428

35424

... More
Supply of HDGI flat of size 25mm x 5mm for earthing of RMU's

10

116

1160

... More
Supply & providing of Centering and shuttering including struttings, propping etc. and removal of formwork for a) Foundations, footings, bases of columns and mass concrete for RMU's

5.64

563

3175.32

... More
Supply & providing of 12 mm cement plaster 1:4 ( 1 cement: 4 fine sand) for foundations of RMU's

1.7

147

249.9

... More
Supply of RCC Hume Pipe 150mm dia with required no. of collars, for road crossing.

10

317

3170

... More
Supply of GI pipe,150mm dia, Class B for bridge crossing.

43

1681

72283

... More
Erection Cost

-

-

-

... More
Erection of RCC pole 9mtrs long 9meters long R.C.C. Pole conforming to IS standards as amended upto date. The Component used for pole shall conform to following IS amended upto date. Ordinary Port land cement 53 grade IS 12269 Aggregate IS 383-1970 Torsteel IS 1786-7985 MS bar IS 432 P 1&2-1982 The minimum ultimate transverse load of pole shall be 300Kg for 9mtr. RCC Pole respectively and factor of safety shall be 2.5. The pole shall be marked as per IS. The poles shall be tested as per IS 785 & 2905-1989 as amended upto date at the manufactures works in the presence of the departmental representative and test reports shall be furnished for acceptance. The poles will be accepted subject to passing of tests and verification of reinforcement and concrete after breaking one pole from each lot at cost of the manufacturer.

3

4408

13224

... More
Fixing of Cut point Channel 1.3 mtr long Cross arms shall be made of HDGI channel of size ISMC 75X40X7.3mm. hot dip galvanizing generally conforming to IS – 2633/72 . The cross arm shall not be welded/joined at any place except as specified. The cross arms shall be fitted horizontally on to the top end of the poles at a height conforming to the relevant I.E. Rules and utilizing suitable size of HDGI clamps, HDGI Nut & Bolts.The length of cut point cross arm should be 1.3 mtrs

1

492

492

... More
Fixing of HDGI top fitting 'x' arm channel (75 x 40mm) Supply & fixing of HDGI Top fitting cross arm ISMC channel,75x40mm,0.7mts long. The cross arms shall be fitted vertically onto the top end of the poles, at a height conforming to the relevant I.E. rules & utilizing suitable size of HDGI clamps & HDGI washers, HDGI nut bolts.

1

228

228

... More
Fixing of 11KV Disc insulators 45KN with metal parts upply & fixing of 11kv Disc insulators with metal parts 45KN 11 KV disc insulators ball and socket type, type ‘A’ porcelain brown glazed duly cemented at factory with MCI socket cap, forged steel ball pin and supplied with Phosphor bronze “W” split pin as per IS 731-1971 as amended upto date. Minimum failing load. 45 KN.Pin ball diameter 16 mm. Minimum Creepage distance 320 mm. Ferrous parts shall be galvanized as per relevant IS. Insulator shall be marked as per IS. Acceptance tests and routine tests shall be carried out as per IS by the manufacturer and test results shall be furnished by the manufacturer before supply of materials.Department reserves the right to witness all the above tests. 3-bolted type hardware fitting suitable for 11KV ball and socket type disc insulators of 16mm pin, failing load of 45KN and suitable for ACSR WEASEL conductor. The metal parts shall conform to IS-2486 Part 1-1993, 2486 Part 2-1989 as amended upto date.All iron parts should be hot dip galvanized as per IS:2629/1985 as amended upto date. Acceptance tests and routine tests shall be carried out by the manufacturer’s works and test reports shall be furnished before supply of materials. Department reserves the right to witness the above testing

3

332

996

... More
Fixing of 11KV Pin insulators with G.I. pins LT pin insulator with HDGI pin The pin insulators shall be of sound, free from defects, thoroughly vitrified & smoothly glazed of brown color except for the screw threads & the parts on which the porcelain is supported. The insulator shall be in one piece. The pin insulator shall have a top groove & shall be threaded to take mild steel pins & shall conform to IS: 1445-1977. The pin shall be suitable for the minimum failing load of 3.5KN. The insula¬tor shall comply to the tests as per IS: 1445. The fittings shall be conf to IS: 7935-1975 or the latest version thereof . The ferrous pin, nuts & washers except those made of stainless steel shall be hot dipped galvanized. The threads of nuts shall be cut after galvanizing & shall be well oiled & greased. The pin shall have a stalk length of 135mm, shank length of 125mm & minimum failing load of 2.0 KN,.

3

152

456

... More
Providing Stay sets complete for 9 mtr RCC pole Supply & providing of Stay sets complete for 9 mtr RCC pole HDGI Stay Sets Complete Comprising of stay rod with plate, HDGI stay wire of size 7/10swg, Break insulator of 15KV/8KV,HDGI turn buckle with eye bolt, suitable HDGI stay clamps, HDGI nut bolts, conforming to drawings approved. The Stay wire shall comply with the specific requirements of IS: 2141-1979, IS: 4826-1979 & IS: 6594-1974 or the latest versions thereof. The wires shall be of tensile grade 4 & having minimum tensile strength of 700 N/mm2 conforming to IS: 2141. GI stay rod of 1800mm long and 16mm dia with an eye band of internal dia 40mm at one end and threaded up to length of 200mm at the other end galvanized. GI stay plate of 450x450x8mm size with a hole drilled at the centre to suit 16mm dia GI rod galvanized. GI stay wire standard of size 7/3.15mm (7/10SWG) wire should conform to ISS-2141/68 grade I and hot dipped galvanized as per IS 4826/1968 with up to date amendments. Two nos of GI square washer of size 40x40x6mm to suit the 16mm dia GI rod. Two nos of GI hexagonal nut and bolt suitable for threaded portion of the stay rod mentioned above and conforming to IS-1365/67 with amendment No-1. All the GI materials shall conform to IS-226/75 with amendment No- 1 to 3 tested quality. The breaking load shall be 63KN min proof load (40% of breaking load shall be performed on all the stay sets. These figures have been taken from IS-16/74 with amendment No. Conforming to Drawing enclosed. Turn buckle with eye bolts for 11KV line & conforming to the following. One no of turn buckle made out of 16mm dia GI rod and 50x50x6mm M.S. angle galvanized. One eye bolt made out of 20mm dia GI rod with 40mm inner dia eye at one end threaded up to 300mm length from the other side. Two no’s GI nuts suitable for the threaded portion of eye bolt material specification IS-226/77 (tested quality) The breaking load and proof load shall be as per BS16/64 with amendment No-1. GI wire with tensile strength 32Kg/mm to 55Kg/mm soft quality 4.00mm dia 8SWG wire should conform to ISS-280/1972 and galvanized to heavy type as per ISS-4826/1968 with up to date amendments. The strain insulators shall be sound, free from defects, thoroughly vitrified & smoothly glazed & shall comply with the IS: 5300-1969 or the latest version thereof. The L.T. strain insulator shall have a minimum failing load of 44KN.

3

2466

7398

... More
Fixing of HDGI nuts and bolts 100 X 16 mm HDGI nut & bolt The bolts and nuts shall be hot dip galvanized as per IS: 2629-1985 as amended upto date. Bolts and nuts shall be supplied in bags of 25 kgs each. The testing of galvanization of bolts and nuts shall be carried out by the manufacturer and test reports shall be furnished before supply of materials. Department reserves the right to witness above testing.

12

30

360

... More
Supply and providing Enamelled Danger boards for 11 KV Enamelled danger board 440Volts/ 11000 Volts /3300 Volts:The plate should be made from mild steel at least 1.6mm thick and vitreous enamelled whitewith letters,figures, and convectional skull and bones in singnal red colour on the front sidfe. The rear side of the plate shall be enamelled .All lettering should be centrally spaced the corners of the plate should be rounded offSizw "250mm x 200mm.

3

57

171

... More
Supply and providing Anti climbing devices with clamps(barbed wire) Hot dip galvanized steel barbed wire type 4 conforming to IS:278/1962 as amended upto date and galvanization conforming to IS:4826/1979as amended upto date. Nominal diameter of line wire and point wire shall be 2.24mm each. Nominal distance between the two barbs shall be 150mm. The weight of the each coil shall be 25 to 35 kg exclusive of weight of the reel.Tests as per IS shall be carried out at the manufacturer’s work & test reports shall be furnished before supply of materials. The department reserves the right to witness all the above tests.

6

46

276

... More
Erection of H.D.G.I. DP Structure materials M.S. Angle of size 50 x 50 x 6 mm of minimum tensile strength 410 MPa conforming to IS 2062 as amended upto date.The sectional weight of steel shall be 4.5kg/m.The length of each piece shall be 4.5m to 6m.The rolling and cutting tolerances for weight and dimensions of steel shall be as per IS 1852-1985.Tests as per IS shall be carried out at the manufacturers works and test reports shall be furnished before supply of materials. The Department reserves the right to witness all the above tests. M.S. Channel 100 X 50 MM ISMC of minimum tensile strength 410 MPa conforming to IS 2062 as amended up to date.The sectional weight of steel shall be 9.2kg/m for M.S. Channel 100x50x6 MM ISMC. The sectional weight of steel shall be 7.14kg/m for M.S. Channel 75x40x6 MM ISMC The length of each piece shall be 4.5m to 6m. The rolling and cutting tolerances for weight and dimensions of steel shall be as per IS 1852-1985. Tests as per IS shall be carried out at the manufacturers works and test reports shall be furnished before supply of materials. The Department reserves the right to witness all the above tests.

374

47

17578

... More
Fixing of LA stay clamps for 9mt RCC pole All clamps & suitable nut bolts shall be hot dipped galvanized generally conforming to IS - 2633/72 & should be fitted with nut bolts.

11

79

869

... More
Fixing of SA stay clamps for 9mt RCC pole All clamps & suitable nut bolts shall be hot dipped galvanized generally conforming to IS - 2633/72 &should be fitted with nut bolts.

3

79

237

... More
Fixing of SA X arm clamps for 9mt RCC pole All clamps & suitable nut bolts shall be hot dipped galvanized generally conforming to IS - 2633/72 & should be fitted with nut bolts.

6

45

270

... More
Fixing of LA X arm clamps for 9mt RCC pole All clamps & suitable nut bolts shall be hot dipped galvanized generally conforming to IS - 2633/72 & should be fitted with nut bolts.

3

45

135

... More
Fixing of G.I. 4 pin LT X arm channel type 75x40mm. The cross arms shall be fitted vertically onto the top end of the poles, at a height conforming to the relevant I.E. rules & utilizing suitable size of HDGI clamps & HDGI washers, HDGI nut bolts.

3

261

783

... More
Fixing of G.I. 2 pin LT X arm channel type 75x40mm. The cross arms shall be fitted vertically onto the top end of the poles, at a height conforming to the relevant I.E. rules & utilizing suitable size of HDGI clamps & HDGI washers, HDGI nut bolts.

14

232

3248

... More
Erection, testing & commissioing of 11 KV GOAB switch 200A 12 KV rated voltage GOAB switches tilting type, outdoor, manually operated, triple pole, single break, conforming to IS: 9921-Part1 to V as amended upto date and detailed specifications enclosed herewith. Each set shall comprise of six pedestal and three tilting post insulators. Insulator should be factory cemented by the manufactures of the insulators and have minimum 320mm creepage distance and AB switches contacts shall be of copper/copper alloy. The AB switches shall be of 200 A current ratings:

2

3971

7942

... More
Providing of Earthing complete with 40mm G.I. pipe,2.5mts long alongwith 20kg each salt, charcoal complete. Supply & providing of Earthing with 40mm, 2.5 mm long GI pipe complete with chamber with brick masonary. Earthing pipe made of Hot Dip galvanized steel tube of heavy class, 40mm nominal bore conforming to IS 1239 Part 1 1990 as amended upto date and Hot Dip zinc coating shall conform to IS 4736-1968 as amended upto date

7

2444

17108

... More
Stringing of ACSR Weasel conductor for earthing & jumpering Includes spreading of ACSR conductor without any damage and stringing with proper tension without any kinks/damage including binding of conductor at pin points, jumpering at cut points etc. The ground & line clearances at road crossings, along roads, Crossings & other crossings shall be as the relevant I.E. Rules. Tree cutting wherever required is to be carried out before stringing of the Conductor with prior permission of the Engineer in charge. The rates for Stringing of conductor in Schedule-II shall include cost of tree cutting as well.

0.15

7110

1030.95

... More
Erection,testing & commissioning of HG fuse unit 11 KV 200A 11 KV H. G. fuse unit shall be as per detailed specifications enclosed herewith Routine tests and acceptance for post insulators as per IS-2544-1973 as amended upto date and shall be carried out at the manufacturers works and test reports shall be furnished before supply of materials. The Department reserves the right to witness all the above tests.

2

3368

6736

... More
Fixing of 9 KV 5 KA lightening arrestors 9 KV, 5 KA nominal discharge current Metal Oxide gapless distribution class lightning arrestor conforming to IEC-60099-4 and IS 3070 Part 3 1993 as amended upto date suitable for 11 KV 50 HZ effectively earthed neutral system with necessary mounting arrangements and connector suitable to connect ACSR conductor upto overall diameter 12.30 mm. The marking of the Lightning Arrestors shall be as per IS. The Acceptance tests and routine tests shall be carried out at the manufacturers works and test reports shall be furnished before supply of materials. The Department reserves the right to witness all the above tests.

6

174

1044

... More
Fixing of Distribution Box(MS) with 400A MCCB & kit kat fuses The MS distribution box shall be designed as per the general specifications . The same shall be manufactured and supplied only after the Executive Engineer has approved the design and after the Executive Engineer accepts sample. After acceptance of the sample the Distribution box shall be supplied & erected. The distribution box should be mounted vertically on the ground with proper foundation. The rate specified is inclusive of foundation work, etc. The Distribution box shall be provided with two doors & MCCB of 400A capacity and Kit Kat fuses with 200A ratings shall be provided. A separate compartment with a separate door with sealing arrangement, exclusively for energy meter shall be provided.

1

8795

8795

... More
Fixing of DTC metering unit

1

1072

1072

... More
Laying of XLPE single core unarmoured cable 240sq.mm.1.1KV grade

40

200

8000

... More
Laying of XLPE single core unarmoured cable 120sq.mm.1.1KV grade(for feeders & Neutral)

80

95

7600

... More
Erection,testing & commissioning of 100 KVA, Distribution transformer

1

11017

11017

... More
Providing of Alluminium crimp lugs 240 sq. mm. Aluminium crimping lugs shall conform to IS:8309-1976 as amended upto date.Lugs shall be made of aluminium of grade 1E of IS 5082-1969 suitable for aluminium cables. Tests as per IS shall be carried out at manufacturers work and test reports shall be furnished before supply of materials.

8

101

808

... More
Providing of Alluminium crimp lugs 120 sq. mm. Aluminium crimping lugs shall conform to IS:8309-1976 as amended upto date.Lugs shall be made of aluminium of grade 1E of IS 5082-1969 suitable for aluminium cables .Tests as per IS shall be carried out at manufacturers work and test reports shall be furnished before supply of materials.

8

88

704

... More
Providing of Alluminium crimp lugs 70 sq. mm.( for Earthing and Jumpering ) Aluminium crimping lugs shall conform to IS:8309-1976 as amended upto date.Lugs shall be made of aluminium of grade 1E of IS 5082-1969 suitable for aluminium cables. Tests as per IS shall be carried out at manufacturers work and test reports shall be furnished before supply of materials.

23

59

1357

... More
Stringing of AA conductor ANT Includes spreading of AAC Conductors without any damage and stringing with proper tension without any kinks/damage including binding of conductor at pin points, jumpering at cut points, guard loops.. etc. The ground & line clearances at road crossings, along roads, L.T. crossings & other crossings shall be as the relevant I.E. rules. Tree cutting wherever required is to be carried out before stringing of the Conductor with prior permission of the Engineer in charge. The rates for Stringing of conductor in Schedule-II shall in¬clude cost of tree cutting as well. AAC Ant conductor for phases.

0.36

6634

2388.24

... More
Stringing of AA conductor GNAT Includes spreading of AAC Conductors without any damage and stringing with proper tension without any kinks/damage including binding of conductor at pin points, jumpering at cut points, guard loops.. etc. The ground & line clearances at road crossings, along roads, L.T. crossings & other crossings shall be as the relevant I.E. rules. Tree cutting wherever required is to be carried out before stringing of the Conductor with prior permission of the Engineer in charge. The rates for Stringing of conductor in Schedule-II shall in¬clude cost of tree cutting as well. GNAT conductor for double neutral, & guard loops.

0.36

6183

2225.88

... More
Fixing of LT 4 Pin cross arm channel type

2

261

522

... More
Fixing of LT Pin insulator with GI Pin

4

232

928

... More
Fixing of LT Shackle insulator with metal parts

15

208

3120

... More
Providing of FRP fencing complete with gate as per specification for distribution transformer(Size : 4MX3MX2M) with Concreting for FRP Fencing support with plinth (0.3x0.3x0.5) Cu.m x12 nos. Each ratio 1:3:6

1

35000

35000

... More
Laying of 11KV, 3 core, 300 sq.mm. aluminium, XLPE insulated, flat wire armoured, 11 KV (Earthed) Cable

484.5

342

165699

... More
Laying of 11KV, 3 core 185sq.mm aluminium, XLPE insulated, flat wire armoured, 11 KV (Earthed) Cable

32

263

8416

... More
Erection, testing & comissioning of 3 WAY RMU ,11KV, 630 Amps,21 kA, 3 sec, SF6 Outdoor RMU- 2 LBS+ 1 CB Extension/Non-Extendable Two(2) Motor operated load break switches (LBS) with Manual operated earthing switches in SF6 and One (1) vaccum circuir breaker with electrical closing and tripping along with disonnector and earthing switches SCADA Compatible and basic channel. Battery charger along woth batetried required for electrical opearations of RMU is in the scope of bidder .Each module shall consisit of VPIS,FPIin LBS Module(N-1) but not less than 1 nos per RMU. Suitable arranegment for mounting FRTU, modem or Ethernet Switch/LIU along with baterry, battery charger shall be provided in RMU

1

9720

9720

... More
Erection of 11KV, 3 phase, Outdoor type, heat shrinkable end termination kit complete, for 11 KV XLPE cable of size 3 x 300sq.mm including sockets/lugs/connectors etc.

1

2718

2718

... More
Erection of 11KV, 3 phase, Indoor type, heat shrinkable end termination kit complete, for 11 KV XLPE cable of size 3 x 300 sq.mm including sockets/lugs/connectors etc. for connecting RMU for main section side .

1

2548

2548

... More
Erection of 11KV 3 phase outdoor terminating kit complete, for 11 KV XLPE cable of size 3 x 185 sq.mm including sockets/lugs/connectors etc. for connecting 11KV end of Distribution transformer .

1

2648

2648

... More
Erection of 11KV 3 phase indoor terminating kit complete, for 11 KV XLPE cable of size 3 x 185 sq.mm including sockets/lugs/connectors etc. for connecting RMU for main section side .

1

2548

2548

... More
Erection of straight through joint complete for 11 KV XLPE cable of size 3 x 300 sq.mm including sockets/lugs/connectors etc. .

2

3713

7426

... More
Erection of RCC Cable route Markers (400 x 900 x 100 mm)

5

256

1280

... More
Excavation in any type of soil including hard laterite soil by mechanical means( hydraulic excavator)/manual means for laying of HT/ LT cables of various sizes including excavation for equipment foundations i.e for RMU's including getting out the excavated soil and disposal of surplus excavated soil.

209.73

468

98153.64

... More
Refilling of excavated soil in the foundations, trenches etc. with available excavated earth in layers not exceeding 20 cm depth, cosolidating each layer by ramming and watering lead upto 50 M and all lifts and disposal of surplus earth in cable trenches and foundations of equipments.

170.74

120

20488.8

... More
Laying of vibro press RCC protective covers of size 480mm long x 250mm width and 50 mm thick capable of bearing load of 135 Kg. And covered with earth/sand upto depth of 0.15 mts. Conforming to IS 1255-1967 at non-road crossing

969

60

58140

... More
Erection of G.I. earthing pipe, 2500mm long, 40mm nominal dia, class B, perforated for RMU's The pit shall be filled with homogenous mixture of 20Kgs of Charcoal, 20Kgs of salt and sand /soil with Brick masonary Chambers The work includes excavation, backfilling & spreading of excavated surplace earth evenly at RMU's.

8

2665

21320

... More
Erection of HDGI flat of size 25mm x 5mm for earthing of RMU's

10

48

480

... More
Laying of RCC Hume Pipe 150mm dia with required no. of collars, for road crossing.

10

151

1510

... More
Laying of GI pipe,150mm dia, Class B for bridge crossing.

43

182

7826

... More
Carrying out detailed physical survey of the area including detailed GPS survey which includes indicating and marking location of other utilities if any

0.45

15000

6750

... More
Laterite Masonary Work Rubber packing with hard laterite stone under floors inlcuding watering ,railing and consolidating etc in pipeline trenches and other foundation completete for single circuit 11KV cable trench

1.4

2211

3100.93



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements

Past Bidders
This list is curated from the bidders of the similar tenders in the past

Unlock the Tender details for free
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.