Electricity Department Tender

View complete overview of Goa Electricity Department Tender

Electricity Department Tender

Works
Electronics Equipment
Electrical and Electronics
Eprocure
Opening Date14 Dec 2024
Closing Soon31 Dec 2024
Tender Amount₹ 6,74,90,978 
Notes
Download

Costs

  • EMD

    ₹ 13,49,820
  • Document Cost

    ₹ 1,500
  • Tender Fee

    ₹ 6,000

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
Supply of RCC Poles 7.5 mtr long as per drawing CEE/C-837

499

6092

3039908

... More
Supply of G.I stay rod & plate LT/11KV line [Galvanising should be hot dipped Galvanised as per IS:2629/66, minimum Zinc coating of 1000 gms/sq.mtr, 140 Microns DFT), suitable for high salinity coastal areas]

679

2404

1632316

... More
Supply of HDGI Turn Buckle with eye bolt 11KV (as per drawing no.CEE/E-500) [Galvanising should be hot dipped Galvanised as per IS:2629/66, minimum Zinc coating of 1000 gms/sq.mtr, 140 Microns DFT), suitable for high salinity coastal areas]

679

677

459683

... More
Supply of HDG.I stay wire 7/10 SWG The stay wire shall comply with the specific requirements of IS:2141-1979, IS:4826-1979 & IS:6594-1974 or the latest versions thereof. The wires shall be of tensile grade 4 & having minimun tensile strength of 700 N/mm2 conforming to IS:2141 HDGI stay wire standard of size 7/3.15mm(7/10SWG) wire should conform to ISS-2414/68 grade I and hot dipped galvanized as per IS 4826/1968 with up to date amendments (Galvanizing should be hot dipped Galvanised as per IS:2629/66, minimum Zinc coating of 1000 gms/sqmtr,140 microns DFT), suitable for high salinity coastal areas.

4989

141

703449

... More
Supply and Fixing of Break insulators 8KV(44KN): Guys strain insulators of sizes 90x65mm with minimum failing load of 44 KN and minimum creepage distance of 41mm. Conforming to fig1 and designation "A" of IS:5300/1969 as amended upto date. Insulators shall have marking and packing as prescribed in IS. Accepatance tests and routine tests shall be carried out as per IS and test results shall be furnished by the manufacturer before supply of materials.

679

176

119504

... More
Supply, transportation, filling and packing by ramming of rubble of hard laterite stone under floors including watering & consolidating with earth and backfilling of poles and stays.

298.27

811

241896.97

... More
Supply of Enamelled danger board 440Volts/11000 Volts/ 3300 Volts: The plate should be made from mild steel at least 1.6mm thick and vitreous enamelled white with letters, figures and convectional skull and bones in signal red color on the front side. The rear side of the plate shall be enamelled. All lettering should be centrally spaced the corners of the plates should be rounded off size" 250mmx 200mm.( as per drawing no EE-II-3/2001,CEE/E/490).

28

248

6944

... More
Supply of HDGI BARBED WIRE FOR ANTICLIMBING DEVICE: Hot dip galvanized steel barbed wire type 4 conforming to IS:278/1962 as amended up to date and galvanization conforming to IS: 4826/1979 as amended up to date. ( Galvanising should be hot dipped Galvanised as per IS:2629/66, minimum Zinc coating of 1000gms/sq.mtr, 140Microns DFT). suiatble for high salinity coastal areas, Nominal distance between the two barbs shall be 150mm. Tests as oer IS shall be carried out at the manufactures work & test reports shall be furnished before supply of materials.

28

145

4060

... More
Supply, fabrication, transportationof Hot dip galvanised DP structure material [Galvanising should be hot dipped Galvanised as per IS:2629/66, minimum Zinc coating of 1000 gms/sq.mtr, 140 Microns DFT), suitable for high salinity coastal areas]

4680

169

790920

... More
Supply, transportation of G.O.A.B. Switch 11 KV (Single break) 12 KV rated voltage GOAB switches tilting type, outdoor, manually operated, triple pole, single break, conforming to IS: 9921-Parti to V as amended upto date and detailed specifications enclosed herewith. Each set shall comprise of six pedestal and three tilting post insulators. Insulator should be factory cemented by the manufactures of the insulators and have minimum 320mm creepage distance and AB switches contacts shall be of copper/copper alloy. The entire unit should be supplied from one supplier/ of same make, assembled GOAB switch not to be accepted Galvanising of all the materials used should be hot dipped Galvanised as per IS:2629/66, (Galvanising should be hot clipped Galvanised as per IS:2629/66, minimum Zinc coating of 1000 gms/sq.mtr, 140 Microns DFT), suitable for high salinity coastal areas)The AB switch shall be of following current rating: G.O.A.B. Switch 11 KV 200 Amps with operating pipe support of class B, 25mm dia., HDGI

19

23535

447165

... More
Supply of 11 KV H. G. fuse unit shall be as per enclosed drawing No. CEE/E-672 and CEE/E-641 and detailed specifications enclosed herewith Routine tests and acceptance for post insulators as per IS-2544-1973 as amended upto date and shall be carried out at the manufacturers works and test reports shall be furnished before supply of materials. Base channel of 75x40 mm (ISMC), I4DGI, Insulator 11KV: 3.4.1 The isolators shall be provided with 6 nos. of 24 kV post insulator per pole for 36 kV and 3 nos. of 24 kV post insulator per pole for 12 kV. There will be total of 18 such post insulators in one set of isolator for 36 kV and 9 such post insulators in one set of isolator for 12 kV. These insulators shall conform to latest amendment of IS: 2544 and IS: 5350 (Part-Ill). Aluminium connector with bi-metallic strip, Homs: Copper (tinted) of 7mm dia, Whisel of copper alloy, fly nut with bolt of brass for connecting fuse wire Earthing terminal with GI nut bolt and plain washer on base channel, Hom holder of copper alloy, Pad of copper alloy The vertical operating rod shall comprise of 40 mm galvanized steel tube (medium class) as per IS: 1161. Length of the rod shall depend on the mounting position of the isolator. Operating handle shall be fixed to the concrete structures (approx. 1 meters above the ground level.). The vertical tube shall be galvanized as per IS: 4736 The entire unit should be supplied from one supplier/ of same make, assembled GOAB switch not to be accepted Galvanising of all the materials used should be hot dipped Galvanised as per IS:2629/66, (Galvanising should be hot dipped Galvanised as per IS:2629/66, minimum Zinc coating of 1000 gms/sq.mtr, 140 Microns DFT), suitable for high salinity coastal areas) H.G. Fuse unit 11 KV 200 Amps

14

10450

146300

... More
Supply of LIGHTNING/SURGE ARRESTORS (As per specifications enclosed) Lightning/Surge Arrestors 9 KV, 5 KA nominal discharge current Metal Oxide gapless distribution class lightning arrestor conforming to IEC-60099-4 and IS 3070 Part 3 1993 as amended upto date suitable for 11 KV 50 HZ effectively earthed neutral system with necessary mounting arrangements and connector suitable to connect ACSR conductor upto overall diameter 12.30 mm.The marking of the Lightning Arrestors shall be as per IS The Acceptance tests and routine tests shall be carried out at the manufacturers works and test reports shall be furnished before supply of materials.

42

3033

127386

... More
Supply of HDGI stay clamps for RCC Pole 11.OO Mts L.A/S.A, (Dimensions/specifications as per drawing no. CEE/E-711) [Galvanising should be hot dipped Galvanised as per IS:2629/66, minimum Zinc coating of 1000 gms/sq.mtr, 140 Microns DFT), suitable for high salinity coastal areas]

28

621

17388

... More
Supply of HDGI stay clamps for RCC Pole 9.OO Mts L.A/S.A, (Dimensions/specifications as per drawing no. CEE/E-524) [Galvanising should be hot dipped Galvanised as per IS:2629/66, minimum Zinc coating of 1000 gms/sq.mtr, 140 Microns DFT), suitable for high salinity coastal areas]

92

491

45172

... More
Supply of HDGI stay clamps for RCC Pole 7.5 Mts L.A/S.A, (Dimensions/specifications as per drawing no. CEE/E-523) [Galvanising should be hot dipped Galvanised as per IS:2629/66, minimum Zinc coating of 1000 gms/sq.mtr, 140 Microns DFT), suitable for high salinity coastal areas]

559

311

173849

... More
Supply of HDGI X arm clamps for RCC Pole 11.00 mtr L.A/S.A, (Dimensions/specifications as per drawing no. CEE/E-711) [Galvanising should be hot dipped Galvanised as per IS:2629/66, minimum Zinc coating of 1000 gms/sq.mtr, 140 Microns DFT), suitable for high salinity coastal areas]

196

414

81144

... More
Supply of HDGI X arm clamps for RCC Pole 9.00 mtr L.A/S.A, (Dimensions/specifications as per drawing no. CEE/E-711) [Galvanising should be hot dipped Galvanised as per IS:2629/66, minimum Zinc coating of 1000 gms/sq.mtr, 140 Microns DFT), suitable for high salinity coastal areas]

68

266

18088

... More
Supply of HDGI X arm clamps for RCC Pole 7.50 mtr L.A/S.A, (Dimensions/specifications as per drawing no. CEE/E-711) [Galvanising should be hot dipped Galvanised as per IS:2629/66, minimum Zinc coating of 1000 gms/sq.mtr, 140 Microns DFT), suitable for high salinity coastal areas]

1643

184

302312

... More
Supply of M. S. distribution box As per drawing No.CEE/E-689 Revision No.3 alongwith 12 nos. of 200A Kitkat Porcelain fuse carrier and base with extended terminals conforming in general to drawing No.EE-II/7/2002 with 1 no. moulded case circuit breaker (MCCB), 415V, AC, 50Hz with extended terminals conforming to IS 13947-2 as amended upto date. Distribution Boxes (M.S) with 200Amps MCCB & Kit-Kat fuses

19

48387

919353

... More
Supply of 200 KVA 11KV/0.4KV Distribution Transformers level II losses, Alluminium Winding, with Bimetallic Terminal Connectors, Energy Efficiency Level-TT as per IS: 1180 (Part-1): 2014

7

377405

2641835

... More
Supply of Disc insulators ball and socket type, type ‘A’ porcelain brown glazed duly cemented at factory with MCI socket cap, forged steel ball pin and supplied with Phosphor bronze “W” split pin as per IS 731-1971 as amended upto date. Minimum failing load. Pin ball diameter 16 mm. Minimum Creepage distance 320 mm. Ferrous parts shall be galvanized as per relevant IS. Insulator shall be marked as per IS. Acceptance tests and routine tests shall be carried out as per IS by the manufacturer and test results shall be furnished by the manufacturer before supply of materials. 70 KN. Disc insulators 70 KN 3-bolted type hardware fitting 70KN suitable for 11 KV ball and socket type disc insulators of 18mm pin, failing load of 70KN. Conform to IS-2486 Part 1-1993, 2486 Part 2-1989 as amended upto date.

96

2886

277056

... More
Supply of 11 KV Pin Insulators 11 KV brown glazed porcelain pin insulator with minimum failing load of 5 KN and the Minimum creepage distance of 320 mm conforming to IS 731-1971 as amended upto date. Insulators shall be marked and packed as per IS. Routine tests and acceptance tests as per IS shall be carried at the manufacturers works and test results shall be furnished before supply of materials.

180

454

81720

... More
Supply of G.I. Pin for I l KV Pin Insulators Forged G. I. Pin conforming to IS 2486 part 1 & 2 as amended upto date suitable for 11 KV glazed porcelain pin insulators conforming to IS: 731/71 as amended upto date. G. I pin shall conform to reference S-165 N fig. 5 of IS: 2486/ (part-11)/74 as amended upto date. Dimensions ‘X5 in said fig. shall be 150 mm (screwed 100 mm). Pin shall be supplied along with one suitable G. I, hexagonal nut and G. 1. spring washer. Minimum failing load of pin shall be 10 KN. G. I. pins and nuts shall be hot dip galvanized as per lS: 2629/66 as amended up to date. The washers shall be electro galvanized. Acceptance tests and Routine tests shall be carried out at the manufacturers works and test reports shal! be furnished before supply of materials.

180

239

43020

... More
Supply of HDGI 11 KV V-shape 'X' arm of channel ISMC 75 (75 x 40mm) [Galvanising should be hot dipped Galvanised as per IS:2629/66, minimum Zinc coating of 1000 gms/sq.mtr, 140 Microns DFT), suitable for high salinity coastal areas]

42

1469

61698

... More
Supply of Cut point 'X' arm of channel of ISMC 75 (75 x 40 mm) 1.3 Mtr long for 11KV, Cross arm not to be welded/joined at any place. Guard 'X' arm of channel ISMC 75 (75 x 40 mm) 1.5 Mtr Long for 11KV, Cross arm not to be welded/joined at any place. [Galvanising should be hot dipped Galvanised as per IS:2629/66, minimum Zinc coating of 1000 gms/sq.mtr, 140 Microns DFT), suitable for high salinity coastal areas]

14

4155

58170

... More
Supply of HDGI Top fitting cross arm ISMC channel, ISMC 75 (75 x 40mm), 0.7mts long for 11KV, Cross arm not to be welded/joined at any place. [Galvanising should be hot dipped Galvanised as per IS:2629/66, minimum Zinc coating of 1000 gms/sq.mtr, 140 Microns DFT), suitable for high salinity coastal areas]

14

819

11466

... More
Supply of Earthing complete with 40mm GI Pipe, 2.5 mts long alongwith 20 kgs each salt, charcoal complete. [Galvanising should be hot dipped Galvanised as per IS:2629/66, minimum Zinc coating of 1000 gms/sq.mtr, 140 Microns DFT), suitable for high salinity coastal areas]

363

2730

990990

... More
Supply of ACSR CONDUCTOR Hard drawn stranded aluminium conductor with galvanised steel wire reinforced conforming to TS: 398(Pt-Il/96) amended upto date of the following sizes. Packing and marking of drum will be as per IS, Materials shall be supplied on non-returnable wooden drums. The type tests and acceptance tests and routine tests shall be carried out at manufacturers works and test reports shall be furnished before supply of materials. The Department reserves right to witness all the above tests. ACSR conductor 'WEASEL' 6 +1 / 2.59 mm nominal aluminium area 30mm2 (139 amps max. at 45° C)

4.5

40100

180450

... More
Supply of AA CONDUCTOR Hard drawn stranded all aluminium conductor conforming to IS: 398(Pt-I/96) as amended upto date of following sizes. Packing and marking of drum will be as per IS: Materials shall be supplied on non-returnable wooden drums. Acceptance tests and routine tests shall be carried out at manufacturers works and test reports shall be furnished before supply of materials. The Department reserves right to witness all the above tests. ANT' conductor 7/3.10 mm nominal aluminium area 50mm2 (190 amps max. at 40° C)

254.9

60500

15421450

... More
Supply of GNAT' conductor 7/2.21 mm nominal aluminium area 25mm2 (80 amps max. at 40° C)

288.9

31000

8955900

... More
Suppply of HDGI 4 pin 'X' arm ofISMC 75 (75 x 40mm) Channel 1.5 mtr length, Cross arm not to be welded/joined at any place, Galvanising should be hoi dipped (Dimensions/specifications as per drawing no: CEE/E/705). [Galvanising should be hot dipped Galvanised as per IS:2629/66, minimum Zinc coating of 1000 gms/sq.mtr, 140 Microns DFT), suitable for high salinity coastal areas]

1112

1109

1233208

... More
Supply of HDGI 2 pin 'X' arm ofISMC 75 (75 x 40 mm) Channel 0.75 mtr length, Cross arm not to be welded/joined at any place, (Dimensions/specifications as per drawing no: CEE/E/704). [Galvanising should be hot dipped Galvanised as per IS:2629/66, minimum Zinc coating of 1000 gms/sq.mtr, 140 Microns DFT), suitable for high salinity coastal areas]

1263

569

718647

... More
Supply of L.T. Pin Insulators L. T. brown glazed porcelain pin insulators of size 100mm x 70mm conforming to type 1 fig 1 of IS:1445/1977 with amendment 2 of Feb. 1981 (second revision) as amended upto date. Minimum failing load shall be 3.5kN. Insulators shall have marking and packing as prescribed in IS. Acceptance tests and routine tests shall be carried out as per IS at manufacturers works and test results shall be furnished by the manufacturer before supply of materials. G.l. Pin for L.T.Pin InsulatorsForged G. I. Pin conforming to IS 7935/1975 as amended upto date suitable for L.T. porcelain pin insulator type 1 conforming to fig.l of IS: 1445/77 with amendment No. 2, Feb.1981, of size 100 x 70 mm. G. I. pin shall comprise of G. I. nut and spring washer and con form to fig. No. 2 of IS: 7935/1975. Minimum failing load of pin shall be 3.5 KN. The fitting shall be marked with the manufacturer’s name or trade mark as per IS. The packing shall be as per IS. G. I. pins and nuts shall be hot dip galvanized as per IS: 2629/66 as amended up to date. The washers shall be electro galvanized.Acceptance tests and Routine tests shall be carried out at the manufacturers works and test reports shall be furnished before supply of materials.

3966

263

1043058

... More
Supply of L.T. Shackle insulators: brown glazed shackle insulators of size 100mm x 115mm conforming to fig.No.4 and type 2 of IS: 1445/77 as amended upto date. Minimum failing load shall be 16kN. Insulators shall have marking and packing as prescribed in IS. Acceptance tests and routine tests shall be carried out as per IS at manufacturers works and test results shall be furnished by the manufacturer before supply of materials. Metal parts for L.T. Shackle insulatorsG. T hardware suitable for L. T. shackle insulators of size 100 x 115 mm. conforming to type 2, fig. 4 of IS: 1445/77 as amended upto date. Hardware or fitting shall confonn to fig. 4 of IS 7935-1975 as amended up to date, comprise of 2 G. 1. strips,

2904

372

1080288

... More
Supply of G. I. bolts and 2 nuts with spring washers.All metal parts including nut bolts should be hot dip galvanized as per IS: 2629/66 as amended up to date. Spring washers shall be electro galvanized, (Galvanising should be hot dipped Galvanised as per IS:2629/66, minimum Zinc coating of 1000 gms/sq.mtr, 140 Microns DFT), suitable for high salinity coastal areas. Acceptance tests and routine tests shall be carried out as per IS and test results shall be furnished by the manufacturer before supply of materials.Department reserves the right to witness all the above tests.

1868

228

425904

... More
Supply of single core, 185sq.mm, unarmoured Al conductor XLPE insulated 1.1KV grade power cable as per Technical Specification and as per IS:7098 (Part-I/1988) with latest ammendment carrying ISI mark.

3960

245

970200

... More
Supply of FRP Fencing complete with Gate as per specification for Distribution Transformer (Size 4Mx3Mx2M) with Concreting for FRP Fencing supports with plinth (0.3x0.3x0.5) Cu.m, x 12 nos. Each ratio 1:3:6

13

76667

996671

... More
Supply of FRP Fencing complete with Gate as per specification for Distribution Transformer (Size  3Mx3Mx2M) with Concreting for FRP Fencing supports with plinth (0.3x0.3x0.5) Cu.m. x 12 nos. Each ratio 1:3:6

18

71167

1281006

... More
Supply of PVC wire 2C x 4sq.mm 1.1 KV Grade

1800

24

43200

... More
Supply of PVC wire 2C x 6sq.mm 1.1 KV Grade

1800

32

57600

... More
Supply of PVC wire 2C x 10sq.mm 1.1 KV Grade

1800

39

70200

... More
Supply & crimping of Aluminium lugs, size 185 sq.mm as per technical specification

963

78

75114

... More
Erection

-

-

-

... More
RCC Poles 11 mtr long as per drawing CEE/C-698

48

9800

470400

... More
RCC Poles 9 mtr long as per drawing CEE/C-836

94

5900

554600

... More
RCC Poles 7.5 mtr long as per drawing CEE/C-837

499

5200

2594800

... More
G.I stay rod & plate LT/11KV line (as per drawing no.CEE/E-456R)

679

1779

1207941

... More
G.I Turn Buckle with eye bolt 11KV (as per drawing no.CEE/E-500)

679

267

181293

... More
HDG.I stay wire 7/10 SWG The stay wire shall comply with the specific requirements of IS:2141-1979, IS:4826-1979 & IS:6594-1974 or the latest versions thereof.The wires shall be of tensile grade 4 & having minimun tensile strength of 700 N/mm2 conforming to IS:2141 HDGI stay wire standard of size 7/3.15mm(7/10SWG) wire should conform to ISS-2414/68 grade I and hot dipped galvanized as per IS 4826/1968 with up to date amendments (Galvanizing should be hot dipped Galvanised as per IS:2629/66, minimum Zinc coating of 1000 gms/sqmtr,140 microns DFT), suitable for high salinity coastal areas.

4989

62

309318

... More
Fixing of Break insulators 8KV(44KN): Guys strain insulators of sizes 90x65mm with minimum failing load of 44 KN and minimum creepage distance of 41mm. Conforming to fig1 and designation "A" of IS:5300/1969 as amended upto date. Insulators shall have marking and packing as prescribed in IS. Accepatance tests and routine tests shall be carried out as per IS and test results shall be furnished by the manufacturer before supply of materials.

679

97

65863

... More
Erection of Enamelled danger board 440Volts/11000 Volts/ 3300 Volts: The plate should be made from mild steel at least 1.6mm thick and vitreous enamelled white with letters, figures and convectional skull and bones in signal red color on the front side. The rear side of the plate shall be enamelled. All lettering should be centrally spaced the corners of the plates should be rounded off size" 250mmx 200mm.( as per drawing no EE-II-3/2001,CEE/E/490).

28

57

1596

... More
Fixing of HDGI BARBED WIRE FOR ANTICLIMBING DEVICE: Hot dip galvanized steel barbed wire type 4 conforming to IS:278/1962 as amended up to date and galvanization conforming to IS: 4826/1979 as amended up to date. ( Galvanising should be hot dipped Galvanised as per IS:2629/66, minimum Zinc coating of 1000gms/sq.mtr, 140Microns DFT). suiatble for high salinity coastal areas, Nominal distance between the two barbs shall be 150mm. Tests as oer IS shall be carried out at the manufactures work & test reports shall be furnished before supply of materials.

28

46

1288

... More
Ffabrication, transportation and erection of Hot dip galvanised DP structure material consisting of the following:

4680

47

219960

... More
Erection of G.O.A.B. Switch 11 KV (Single break) 12 KV rated voltage GOAB switches tilting type, outdoor, manually operated, triple pole, single break, conforming to IS: 9921-Parti to V as amended upto date and detailed specifications enclosed herewith. Each set shall comprise of six pedestal and three tilting post insulators. Insulator should be factory cemented by the manufactures of the insulators and have minimum 320mm creepage distance and AB switches contacts shall be of copper/copper alloy. The entire unit should be supplied from one supplier/ of same make, assembled GOAB switch not to be accepted Galvanising of all the materials used should be hot dipped Galvanised as per IS:2629/66, (Galvanising should be hot clipped Galvanised as per IS:2629/66, minimum Zinc coating of 1000 gms/sq.mtr, 140 Microns DFT), suitable for high salinity coastal areas)The AB switch shall be of following current rating: G.O.A.B. Switch 11 KV 200 Amps with operating pipe support of class B, 25mm dia., HDGI

19

3971

75449

... More
Fixing of 11 KV H. G. fuse unit shall be as per enclosed drawing No. CEE/E-672 and CEE/E-641 and detailed specifications enclosed herewith Routine tests and acceptance for post insulators as per IS-2544-1973 as amended upto date and shall be carried out at the manufacturers works and test reports shall be furnished before supply of materials. Base channel of 75x40 mm (ISMC), I4DGI, Insulator 11KV: 3.4.1 The isolators shall be provided with 6 nos. of 24 kV post insulator per pole for 36 kV and 3 nos. of 24 kV post insulator per pole for 12 kV. There will be total of 18 such post insulators in one set of isolator for 36 kV and 9 such post insulators in one set of isolator for 12 kV. These insulators shall conform to latest amendment of IS: 2544 and IS: 5350 (Part-Ill). Aluminium connector with bi-metallic strip, Homs: Copper (tinted) of 7mm dia, Whisel of copper alloy, fly nut with bolt of brass for connecting fuse wire Earthing terminal with GI nut bolt and plain washer on base channel, Hom holder of copper alloy, Pad of copper alloy. The vertical operating rod shall comprise of 40 mm galvanized steel tube (medium class) as per IS: 1161. Length of the rod shall depend on the mounting position of the isolator. Operating handle shall be fixed to the concrete structures (approx. 1 meters above the ground level.). The vertical tube shall be galvanized as per IS: 4736 The entire unit should be supplied from one supplier/ of same make, assembled GOAB switch not to be accepted Galvanising of all the materials used should be hot dipped Galvanised as per IS:2629/66, (Galvanising should be hot dipped Galvanised as per IS:2629/66, minimum Zinc coating of1000 gms/sq.mtr, 140 Microns DFT), suitable for high salinity coastal areas) H.G. Fuse unit 11 KV 200 Amps

14

3368

47152

... More
LIGHTNING/SURGE ARRESTORS (As per specifications enclosed) Lightning/Surge Arrestors 9 KV, 5 KA nominal discharge current Metal Oxide gapless distribution class lightning arrestor conforming to IEC-60099-4 and IS 3070 Part 3 1993 as amended upto date suitable for 11 KV 50 HZ effectively earthed neutral system with necessary mounting arrangements and connector suitable to connect ACSR conductor upto overall diameter 12.30 mm.The marking of the Lightning Arrestors shall be as per IS The Acceptance tests and routine tests shall be carried out at the manufacturers works and test reports shall be furnished before supply of materials.

42

174

7308

... More
Fixing of HDGI stay clamps for RCC Pole 11.OO Mts L.A/S.A, (Dimensions/specifications as per drawing no. CEE/E-711)

28

98

2744

... More
Fixing of HDGI stay clamps for RCC Pole 9.OO Mts L.A/S.A, (Dimensions/specifications as per drawing no. CEE/E-524)

92

79

7268

... More
Fixing of HDGI stay clamps for RCC Pole 7.5 Mts L.A/S.A, (Dimensions/specifications as per drawing no. CEE/E-523)

559

69

38571

... More
Fixing of HDGI X arm clamps for RCC Pole 11.00 mtr L.A/S.A, (Dimensions/specifications as per drawing no. CEE/E-711)

196

65

12740

... More
Fixing of HDGI X arm clamps for RCC Pole 9.00 mtr L.A/S.A, (Dimensions/specifications as per drawing no. CEE/E-711)

68

45

3060

... More
Fixing of HDGI X arm clamps for RCC Pole 7.50 mtr L.A/S.A, (Dimensions/specifications as per drawing no. CEE/E-711)

1643

32

52576

... More
Erection and commissioning of M. S. distribution box As per drawing No.CEE/E-689 Revision No.3 alongwith 12 nos. of 200A Kitkat Porcelain fuse carrier and base with extended terminals conforming in general to drawing No.EE-II/7/2002 with 1 no. moulded case circuit breaker (MCCB), 415V, AC, 50Hz with extended terminals conforming to IS 13947-2 as amended upto date. Distribution Boxes (M.S) with 200Amps MCCB & Kit-Kat fuses

19

4687

89053

... More
Erection, testing and commissioning of 200 KVA 11KV/0.4KV Distribution Transformers level II losses, Alluminium Winding, with Bimetallic Terminal Connectors, Energy Efficiency Level-TT as per IS: 1180 (Part-1): 2014

7

15638

109466

... More
Fixing of Disc insulators ball and socket type, type ‘A’ porcelain brown glazed duly cemented at factory with MCI socket cap, forged steel ball pin and supplied with Phosphor bronze “W” split pin as per IS 731-1971 as amended upto date. Minimum failing load. Pin ball diameter 16 mm. Minimum Creepage distance 320 mm. Ferrous parts shall be galvanized as per relevant IS. Insulator shall be marked as per IS. Acceptance tests and routine tests shall be carried out as per IS by the manufacturer and test results shall be furnished by the manufacturer before supply of materials. 70 KN. Disc insulators 70 KN 3-bolted type hardware fitting 70KN suitable for 11 KV ball and socket type disc insulators of 18mm pin, failing load of 70KN. Conform to IS-2486 Part 1-1993, 2486 Part 2-1989 as amended upto date.

96

375

36000

... More
Erection of 11 KV Pin Insulators 11 KV brown glazed porcelain pin insulator with minimum failing load of 5 KN and the Minimum creepage distance of 320 mm conforming to IS 731-1971 as amended upto date. Insulators shall be marked and packed as per IS. Routine tests and acceptance tests as per IS shall be carried at the manufacturers works and test results shall be furnished before supply of materials.

180

76

13680

... More
G.I. Pin for I l KV Pin Insulators Forged G. I. Pin conforming to IS 2486 part 1 & 2 as amended upto date suitable for 11 KV glazed porcelain pin insulators conforming to IS: 731/71 as amended upto date. G. I pin shall conform to reference S-165 N fig. 5 of IS: 2486/ (part-11)/74 as amended upto date. Dimensions ‘X5 in said fig. shall be 150 mm (screwed 100 mm). Pin shall be supplied along with one suitable G. I, hexagonal nut and G. 1. spring washer. Minimum failing load of pin shall be 10 KN. G. I. pins and nuts shall be hot dip galvanized as per lS: 2629/66 as amended up to date. The washers shall be electro galvanized. Acceptance tests and Routine tests shall be carried out at the manufacturers works and test reports shal! be furnished before supply of materials.

180

76

13680

... More
HDGI 11 KV V-shape 'X' arm of channel ISMC 75 (75 x 40mm)

42

338

14196

... More
Fixing of Cut point 'X' arm of channel of ISMC 75 (75 x 40 mm) 1.3 Mtr long for 11KV, Cross arm not to be welded/joined at any place. Guard 'X' arm of channel ISMC 75 (75 x 40 mm) 1.5 Mtr Long for 11KV, Cross arm not to be welded/joined at any place.

14

1038

14532

... More
Fixing of HDGI Top fitting cross arm ISMC channel, ISMC 75 (75 x 40mm), 0.7mts long for 11KV, Cross arm not to be welded/joined at any place.

14

228

3192

... More
Erection of Earthing complete with 40mm GI Pipe, 2.5 mts long alongwith 20 kgs each salt, charcoal complete.

363

2444

887172

... More
Stringing of ACSR CONDUCTOR Hard drawn stranded aluminium conductor with galvanised steel wire reinforced conforming to TS: 398(Pt-Il/96) amended upto date of the following sizes. Packing and marking of drum will be as per IS, Materials shall be supplied on non-returnable wooden drums. The type tests and acceptance tests and routine tests shall be carried out at manufacturers works and test reports shall be furnished before supply of materials. The Department reserves right to witness all the above tests. ACSR conductor 'WEASEL' 6 +1 / 2.59 mm nominal aluminium area30mm2 (139 amps max. at 45° C)

4.5

11000

49500

... More
Stringing of AA CONDUCTOR Hard drawn stranded all aluminium conductor conforming to IS: 398(Pt-I/96) as amended upto date of following sizes. Packing and marking of drum will be as per IS: Materials shall be supplied on non-returnable wooden drums. Acceptance tests and routine tests shall be carried out at manufacturers works and test reports shall be furnished before supply of materials. The Department reserves right to witness all the above tests. ANT' conductor 7/3.10 mm nominal aluminium area 50mm2 (190 amps max. at 40° C)

254.9

10300

2625470

... More
GNAT' conductor 7/2.21 mm nominal aluminium area 25mm2 (80 amps max. at 40° C)

288.9

9100

2628990

... More
HDGI 4 pin 'X' arm ofISMC 75 (75 x 40mm) Channel 1.5 mtr length, Cross arm not to be welded/joined at any place, Galvanising should be hoi dipped (Dimensions/specifications as per drawing no: CEE/E/705).

1112

261

290232

... More
HDGI 2 pin 'X' arm ofISMC 75 (75 x 40 mm) Channel 0.75 mtr length, Cross arm not to be welded/joined at any place, (Dimensions/specifications as per drawing no: CEE/E/704).

1263

232

293016

... More
L.T. Pin Insulators L. T. brown glazed porcelain pin insulators of size 100mm x 70mm conforming to type 1 fig 1 of IS:1445/1977 with amendment 2 of Feb. 1981 (second revision) as amended upto date. Minimum failing load shall be 3.5kN. Insulators shall have marking and packing as prescribed in IS. Acceptance tests and routine tests shall be carried out as per IS at manufacturers works and test results shall be furnished by the manufacturer before supply of materials. G.l. Pin for L.T.Pin InsulatorsForged G. I. Pin conforming to IS 7935/1975 as amended upto date suitable for L.T. porcelain pin insulator type 1 conforming to fig.l of IS: 1445/77 with amendment No. 2, Feb.1981, of size 100 x 70 mm. G. I. pin shall comprise of G. I. nut and spring washer and con form to fig. No. 2 of IS: 7935/1975. Minimum failing load of pin shall be 3.5 KN. The fitting shall be marked with the manufacturer’s name or trade mark as per IS. The packing shall be as per IS. G. I. pins and nuts shall be hot dip galvanized as per IS: 2629/66 as amended up to date. The washers shall be electro galvanized.Acceptance tests and Routine tests shall be carried out at the manufacturers works and test reports shall be furnished before supply of materials

3966

173

686118

... More
L.T. Shackle insulators: brown glazed shackle insulators of size 100mm x 115mm conforming to fig.No.4 and type 2 of IS: 1445/77 as amended upto date. Minimum failing load shall be 16kN. Insulators shall have marking and packing as prescribed in IS. Acceptance tests and routine tests shall be carried out as per IS at manufacturers works and test results shall be furnished by the manufacturer before supply of materials. Metal parts for L.T. Shackle insulatorsG. T hardware suitable for L. T. shackle insulators of size 100 x 115 mm. conforming to type 2, fig. 4 of IS: 1445/77 as amended upto date. Hardware or fitting shall confonn to fig. 4 of IS 7935-1975 as amended up to date, comprise of 2 G. 1. strips,

2904

208

604032

... More
G. I. bolts and 2 nuts with spring washers.All metal parts including nut bolts should be hot dip galvanized as per IS: 2629/66 as amended up to date. Spring washers shall be electro galvanized, (Galvanising should be hot dipped Galvanised as per IS:2629/66, minimum Zinc coating of 1000 gms/sq.mtr, 140 Microns DFT), suitable for high salinity coastal areas. Acceptance tests and routine tests shall be carried out as per IS and test results shall be furnished by the manufacturer before supply of materials.Department reserves the right to witness all the above tests.

1868

28

52304

... More
Erection of single core, 185sq.mm, unarmoured Al conductor XLPE insulated 1.1KV grade power cable as per Technical Specification and as per IS:7098 (Part-I/1988) with latest ammendment carrying ISI mark.

3960

170

673200

... More
FRP Fencing complete with Gate as per specification for Distribution Transformer (Size 4Mx3Mx2M) with Concreting for FRP Fencing supports with plinth (0.3x0.3x0.5) Cu.m, x 12 nos. Each ratio 1:3:6

13

35000

455000

... More
Erection of FRP Fencing complete with Gate as per specification for Distribution Transformer (Size  3Mx3Mx2M) with Concreting for FRP Fencing supports with plinth (0.3x0.3x0.5) Cu.m. x 12 nos. Each ratio 1:3:6

18

33667

606006

... More
Erection of PVC wire 2C x 4sq.mm 1.1 KV Grade

1800

8

14400

... More
Erection of PVC wire 2C x 6sq.mm 1.1 KV Grade

1800

9

16200

... More
Erection of PVC wire 2C x 10sq.mm 1.1 KV Grade

1800

11

19800

... More
crimping of Aluminium lugs, size 185 sq.mm as per technical specification

963

95

91485

... More
Removing and re-erection of 30 watts Led lights (existing fixtures)

152

360

54720

... More
Removing and re-erection of 50 watts Led lights (existing fixtures)

46

600

27600

... More
Removing and re-erection of 130 watts Led lights (existing fixtures)

39

1560

60840

... More
Removing of the existing 7.5 m RCC pole

167

2600

434200

... More
Removing of the existing 9.0 m RCC pole

42

2950

123900

... More
Removing of the existing 11.00m RCC pole

28

4900

137200

... More
Removing and re-fixing of the existing service conenction single phase.

1998

12

23976

... More
Removing and re-fixing of the existing service conenction three phase.

461

13

6223.5

... More
Removing of the existing main cable of sizes 3 ½ core 240sq.mm/185sq.mm/120sq.mm

644

136

87584

... More
Removing of the existing feeder cable of sizes 3 ½ core 185sq.mm/120sq.mm/90sq.mm /35sq.mm

14

114

1596

... More
Removing of 4 Pin cross arms assembly with Clamps, Nut & Bolt as per technical specification.

336

130

43848

... More
Removing of 2 Pin cross arms assembly with Clamps, Nut & Bolt as per technical specification.

319

116

37004

... More
Removing of LT shackle insulator

656

104

68224

... More
Removing of LT Pin Insulator

535

86

46277.5

... More
Removing of the existing Old deteriorated ANT conductor as per technical specification.

224.9

5150

1158235

... More
Removing of the existing Old deteriorated GNAT conductor as per technical specification.

208.9

4550

950495

... More
Removing of old 100 kva Distribution Transformer

7

5508

38559.5

... More
Removing and re-hoisting of the existing Transformer of capacity 160KVA/ 200KVA

8

23457

187656

... More
Removing of old existing distibution box

14

3141

43974

... More
Removing of old existing GOAB switch

14

1985

27797

... More
Removing of old exsiting HG fuse units

14

1684

23576

... More
Removing of old existing Lightening arrestors

42

87

3654

... More
Removing of old existing structure materials as per technical specification.

1512

23

35532

... More
Removing of old existing 11 KV disc insulators

42

187

7875

... More
Tree cutting ,dragging of pole etc

1

150000

150000



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements

Past Bidders
This list is curated from the bidders of the similar tenders in the past

Unlock the Tender details for free
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.