Electricity Department Tender

View complete overview of Goa Electricity Department Tender

Electricity Department Tender

Works
Civil And Construction
Eprocure
Opening Date8 Nov 2023
Closing Date9 Dec 2023
Tender Amount₹ 8,16,596 
Notes
Download

Costs

  • EMD

    ₹ 16,332
  • Document Cost

    ₹ 500
  • Tender Fee

    ₹ 1,633

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
Supply of 11 KV rated voltange GOAB switches tilting type, outdoor, manually operated, triple pole, single break, conforming to IS: 9921-Part 1 to V as amended up to date and detailed specification eclosed herewith. Each set shall comprise of six pedestal and three tilting post insulators. Insulator should be factory cemented by the manufacturer of the insulators and have minimum 320 mm creepage distance and AB switchs contacts shall be of copper/ copper alloy. The AB switch shall be of following current rating: 200 A

1

23535

23535

... More
Supply of 11 KV , 200 A Horn gap fuse unit (Set of three) shall be as per enclosed drg No. CEE/E-786. Revision 3 and detailed specifications enclosed herewith.

1

10450

10450

... More
Supply of 9 KV, 5 KA nominal discharge current metal oxide gapless distribution class Lightning arrestor conforming to IEC-600994-4 and IS: 3070 part 3 1993 as amended upto date suitable for 11 KV 50 HZ effectively earthed neutral system with necessary mounting arragements and connector suitable to connect ASCR conductor upto overall diameter 12.30 mm

3

9099

3033

... More
Supply of HDGI structure material for DPS. Each trasformer centre DP consist of HDGI structure material as follows: a) GI channel ISMC 75x40x7.3mm 2.75 mtrs long 2 pieces for incoming line & installation of disc insulators b) GI channel ISMC75x40x7.3mm 2.75mtrs long 2 pieces for GOAB switch c) GI channel ISMC 75x40x7.3mm 2.75 mtrs long 2 pieces for HG fuses d) GI channel ISMC 75x40x7.3mm 2.75 mtrs long 2 pieces for installation of lightening arrestor e) GI channel ISMC 100x50x7.3mm 2.75 mtrs long 2 pieces for installation of Trasformer f) GI channel ISMC 75x40x7.3mm 2.75 mtrs long 2 pieces for side support of trasformer g) GI channel ISMC 75x40x7.3mm 2.75 mtrs long 4 pieces for installation of any other items h) GI channel ISMC 100x40x7.3mm 0.52 mtrs long 2 pieces for installation of Transformer base channel

260

43940

169

... More
Supply of LT/11KV Stay set complete 11Mts long RCC pole

1

4613

4613.57

... More
Supply of LT/11KV Stay set complete 9 Mts long RCC pole

3

13099

4366.54

... More
Supply of HDGI Top Insulator fitting Cross arm ISMC channel 75 x 40 mm, 0.7 mtr with nut bolts long for 11 mts long RCC pole

2

2648

1324.2

... More
Supply of HDGI 11 KV 'V' Shape cross arm of channel ISMC 75 x 40 x 7.3 mm. with HDG Clamp & HDG nut bolts etc. for 11 Mtr. long RCC Pole as pet drg no. CEE/E - 408-R1

2

3948

1974.2

... More
Supply of HDGI cut point crosss arm channel ISMC 75 X40 X 6mm of 1.3 mts long with clamps and nuts & bolts for 11 mts RCC pole

1

2464

2464.2

... More
Supply of 11KV Guard Cross arm 1.5Mts long with clamps & nut bolt for 11mtr RCC pole

4

10804

2701.2

... More
Supply of HDGI L.T. 4 pin cross arm Channel type as above with HDG clamps & HDG nut bolts etc for 11mts long RCC pole as per drg No.CEE/E-491 and drg no. CEE/E-524

4

6456

1614.2

... More
Supply of HDGI L.T. 2 pin cross arm Channel type as above with HDG clamps & HDG nut bolts etc for 11 mts long RCC pole as per drg No.CEE/E-491 and drg no. CEE/E-524

2

2148

1074.2

... More
Supply of HDGI L.T. 4 pin cross arm Channel type as above with HDG clamps & HDG nut bolts etc for 9 mts long RCC pole as per drg No.CEE/E-491 and drg no. CEE/E-524

2

2932

1466.2

... More
Supply of HDGI L.T. 2 pin cross arm Channel type as above with HDG clamps & HDG nut bolts etc for 9 mts long RCC pole as per drg No.CEE/E-491 and drg no. CEE/E-524

2

1852

926.2

... More
Supply of 11 Disc Insulators ball and socket type, A porcelain brown glazed duly cemented at factory with MCI socket cap, forged steel ball pin and supplied with Phosphor bronze "W" split pin as per IS 731-1971 as amended upto date. Minimum failing load 70 KN Pin ball diameter 16 mm. Minimum Creepage distance 320 mm with 2 bolted type hardware fitting 70KN suitable for 11 KV ball and socket type disc insulators of 16 mm pin, failing load of 70 KN and suitable for ACSR conductor of size upto 18 mm diameter. The metal parts shall be as per drg No CC/E-482-Rev-2 Benclosed and conform to IS-2486 part 1-1993, 2486 Part-2-1989 as amended upto date.

3

8658

2886

... More
Supply of 11 KV brown glazed porcelain Pin Insulator with minimum failing load of 5 KN and the minimum creepage distance of 320mm conforming to IS 731-1971 as amended upto date. And forged GI pin conforming to IS 2486 part 1 & 2 as amended upto date suitable for 11 KV glazed porcelain pin insulators conforming to IS 731/71 as amended upto date. GI pin shall conform to reference S-165 N fig 5 of IS 2486/(part-II)/74 as amended upto date. Dimension X in said fig shall be 150mm (screwed 100mm). Pin shall be supplied along with one suitable GI hexagonal nut and GI spring washer. Minimum failing load of pin shall be 10 KN.

6

4158

693

... More
Supply of LT brown glazed shackle Insulator of size 100 mm x 115 mm conforming to fig No. 4 and type 2 fo IS: 1445/77 as amended upto date. Minimum failing load shall be 16 KN with GI hardware suitable for LT shackle insulator of size 100 x 115 mm conforming to type 2 fig 4 of IS: 1445/77 as amended upto date. Hardware or fitting shall conform to fig 4 of IS: 7935-1975 as amended upto date comprise fo 2 GI strips, 2 GI bolts and 2 nuts with spring washers.

48

17856

372

... More
Supply of L.T. brown glazed porcelain pin insulators of size 100mmx70mm conforming to type 1 fig 1 of IS: 1445/1977 with amendment 2 of Feb 1981 (second revision) as amended upto date. Minimum failing load shall be 3.5 KN with Forged GI pin conforming to IS 7935/1975 as amended upto date suitable for LT porcelain pin insulator type 1 conforming to fig 1 of IS: 1445/77 with amendment no 2 feb 1981, of size 100 x 70 mm. GI pin shall comprise of GI nut and spring washer and conform to fig No 2 of IS: 7935/1975. Minimum failing load of pin shall be 3.5 KN

5

1315

263

... More
Supply of ACSR Conductor Hard drawn stranded aluminium conductor with galvanized steel wire reinforced conforming to IS: 398(PartII-96) amended upto date of the following sizes. WEASEL 6/1/2.59 (nominal aluminium area 30 Sq.mm.) (139 amp max at 45 °C) for line

0.3

10022

33409

... More
Supply of Earthing complete with chamber as per drg/ No. CEE/E-830. Each earthing should consist as follows a) 40 mm. Dia 2.5 mtr long, class B GI pipe 1 No. b)HDGI nut bolts, clamps 1 set, c)Brick masonary-0.108 Cu.mts d) PVC pipe 50mm dia- 0.2mtr e) Salt-20 Kgs f) Charcoal-20 Kgs g) Excavation-0.864 Cu. Mtr h) refilling-0.74 Cu.mtr as per drg. No.CEE/E-830.

6

16380

2730

... More
Supply of XPLE insulated single core unarmoured cable 50 mm2 for DP earthing.

55

4565

83

... More
Supply of AA"ANT" conductor

1.2

57655

48086

... More
Supply of AA"GNAT" conductor

1.12

28404

25293

... More
Supply of ACSR Conductor Hard drawn stranded aluminium conductor with galvanized steel wire reinforced conforming to IS: 398(PartII-96) amended upto date of the following sizes. WEASEL 6/1/2.59 (nominal aluminium area 30 Sq.mm.) (139 amp max at 45 °C) for DP earthing and line stringing for guarding

0.99

33008

33409

... More
Supply of MS Distribution box as per drg No. CEE/E-689 Revision No. 3 along with MCCB 400 A, Bus bar made out of Aluminium strips 40 x 10 mm, kit kat fuses for 4 feeder arrangement

1

63140

63140

... More
Supply of XLPE 1.1KV Armored single core unarmoured cable 185 mm²

48

11760

245

... More
Supply of XLPE 1.1KV 3 & 1/2 XLPE Armoured cable 120 mm²

36

32868

913

... More
Supply of Enamelled danger boards 11000 Volts ,250mm x 200mmm as per drg no. CEE/E-490

3

744

248

... More
Supply of Aluminium crimping Lugs shall conform to IS: 8309-1976 as amended upto date. Lugs shall be made of aluminium of grade IE of IS: 5082/1969 suitable for aluminium cable fo sizes 185 Sq.mm.

8

624

78

... More
Supply of Aluminium crimping Lugs shall conform to IS: 8309-1976 as amended upto date. Lugs shall be made of aluminium of grade IE of IS: 5082/1969 suitable for aluminium cable fo sizes 120 Sq.mm.

9

486

54

... More
Supply of Aluminium crimping Lugs shall conform to IS: 8309-1976 as amended upto date. Lugs shall be made of aluminium of grade IE of IS: 5082/1969 suitable for aluminium cable fo sizes 95 Sq.mm.

3

120

40

... More
Supply of Aluminium crimping Lugs shall conform to IS: 8309-1976 as amended upto date. Lugs shall be made of aluminium of grade IE of IS: 5082/1969 suitable for aluminium cable fo sizes50 Sq.mm.

45

990

22

... More
Supply of FRP Fencing complete with Gate as epr specification for distribution transformer (size 4Mx3Mx2M) with Concreting for FRP Fencing supports with plinth (0.3x0.3x0.5)Cu.m.x12nos Each ratio 1;3;6

1

76667

76667

... More
Supply and Erection of Cement concreting 1 : 2:4

2.5

13887

5555

... More
Painting of Pole Numbers

3

312

104.33

... More
Cost of Erection

-

-

-

... More
Erection of RCC pole 11 mtr as per the drawing No.CEE/E-698 REV-3 as per annexure confirming to IS 785-1998 as amended upto date. The component used for pole shall conform to following IS amended up to date. 1) Ordinary Port land cement 53 grade IS 12269 2) Aggregate IS 383-1970 3) Torsteel IS 1786-7985 4) MS bar IS 432 p 1 & 2-1982

3

25800

8600

... More
Erection of RCC pole 9 mtr as per the drawing No.CEE/E-724 REV-3 as per annexure confirming to IS 785-1998 as amended upto date. The component used for pole shall conform to following IS amended up to date. 1) Ordinary Port land cement 53 grade IS 12269 2) Aggregate IS 383-1970 3) Torsteel IS 1786-7985 4) MS bar IS 432 p 1 & 2-1982

1

4408

4408

... More
Erection of 11 KV rated voltange GOAB switches tilting type, outdoor, manually operated, triple pole, single break, conforming to IS: 9921-Part 1 to V as amended up to date and detailed specification eclosed herewith. Each set shall comprise of six pedestal and three tilting post insulators. Insulator should be factory cemented by the manufacturer of the insulators and have minimum 320 mm creepage distance and AB switchs contacts shall be of copper/ copper alloy. The AB switch shall be of following current rating: 200 A

1

3971

3971

... More
Erection of 11 KV , 200 A Horn gap fuse unit (Set of three) shall be as per enclosed drg No. CEE/E-786. Revision 3 and detailed specifications enclosed herewith.

1

3368

3368

... More
Erection of 9 KV, 5 KA nominal discharge current metal oxide gapless distribution class Lightning arrestor conforming to IEC-600994-4 and IS: 3070 part 3 1993 as amended upto date suitable for 11 KV 50 HZ effectively earthed neutral system with necessary mounting arragements and connector suitable to connect ASCR conductor upto overall diameter 12.30 mm

3

522

174

... More
Erection of HDGI structure material for DPS. Each trasformer centre DP consist of HDGI structure material as follows: a) GI channel ISMC 75x40x7.3mm 2.75 mtrs long 2 pieces for incoming line & installation of disc insulators b) GI channel ISMC75x40x7.3mm 2.75mtrs long 2 pieces for GOAB switch c) GI channel ISMC 75x40x7.3mm 2.75 mtrs long 2 pieces for HG fuses d) GI channel ISMC 75x40x7.3mm 2.75 mtrs long 2 pieces for installation of lightening arrestor e) GI channel ISMC 100x50x7.3mm 2.75 mtrs long 2 pieces for installation of Trasformer f) GI channel ISMC 75x40x7.3mm 2.75 mtrs long 2 pieces for side support of trasformer g) GI channel ISMC 75x40x7.3mm 2.75 mtrs long 4 pieces for installation of any other items h) GI channel ISMC 100x40x7.3mm 0.52 mtrs long 2 pieces for installation of Transformer base channel

260

12220

47

... More
Erection of LT/11KV Stay set complete 11Mts long RCC pole

1

2536

2536.34

... More
Erection of LT/11KV Stay set complete 9 Mts long RCC pole

3

7397

2465.88

... More
Erection of HDGI Top Insulator fitting Cross arm ISMC channel 75 x 40 mm, 0.7 mtr with nut bolts long for 11 mts long RCC pole

2

610

305

... More
Erection of HDG 11 KV 'V' Shape cross arm of channel ISMC 75 x 40 x 7.3 mm. with HDG Clamp & HDG nut bolts etc. for 11 Mtr. long RCC Pole as pet drg no. CEE/E - 408-R1

2

830

415

... More
Erection of HDGI cut point crosss arm channel ISMC 75 X40 X 6mm of 1.3 mts long with clamps and nuts & bolts for 11 mts RCC pole

1

569

569

... More
Erection of 11KV Guard Cross arm 1.5Mts long with clamps & nut bolt for 11mtr RCC pole

4

2492

623

... More
Erection of HDGI L.T. 4 pin cross arm Channel type as above with HDG clamps & HDG nut bolts etc for 11mts long RCC pole as per drg No.CEE/E-491 and drg no. CEE/E-524

4

1352

338

... More
Erection of HDGI L.T. 2 pin cross arm Channel type as above with HDG clamps & HDG nut bolts etc for 11 mts long RCC pole as per drg No.CEE/E-491 and drg no. CEE/E-524

2

618

309

... More
Erection of HDGI L.T. 4 pin cross arm Channel type as above with HDG clamps & HDG nut bolts etc for 9 mts long RCC pole as per drg No.CEE/E-491 and drg no. CEE/E-524

2

636

318

... More
Erection of HDGI L.T. 2 pin cross arm Channel type as above with HDG clamps & HDG nut bolts etc for 9 mts long RCC pole as per drg No.CEE/E-491 and drg no. CEE/E-524

2

578

289

... More
Erection of 11 Disc Insulators ball and socket type, A porcelain brown glazed duly cemented at factory with MCI socket cap, forged steel ball pin and supplied with Phosphor bronze "W" split pin as per IS 731-1971 as amended upto date. Minimum failing load 70 KN Pin ball diameter 16 mm. Minimum Creepage distance 320 mm with 2 bolted type hardware fitting 70KN suitable for 11 KV ball and socket type disc insulators of 16 mm pin, failing load of 70 KN and suitable for ACSR conductor of size upto 18 mm diameter. The metal parts shall be as per drg No CC/E-482-Rev-2 Benclosed and conform to IS-2486 part 1-1993, 2486 Part-2-1989 as amended upto date.

3

1125

375

... More
Erection of 11 KV brown glazed porcelain Pin Insulator with minimum failing load of 5 KN and the minimum creepage distance of 320mm conforming to IS 731-1971 as amended upto date. And forged GI pin conforming to IS 2486 part 1 & 2 as amended upto date suitable for 11 KV glazed porcelain pin insulators conforming to IS 731/71 as amended upto date. GI pin shall conform to reference S-165 N fig 5 of IS 2486/(part-II)/74 as amended upto date. Dimension X in said fig shall be 150mm (screwed 100mm). Pin shall be supplied along with one suitable GI hexagonal nut and GI spring washer. Minimum failing load of pin shall be 10 KN.

6

912

152

... More
Erection of LT brown glazed shackle Insulator of size 100 mm x 115 mm conforming to fig No. 4 and type 2 fo IS: 1445/77 as amended upto date. Minimum failing load shall be 16 KN with GI hardware suitable for LT shackle insulator of size 100 x 115 mm conforming to type 2 fig 4 of IS: 1445/77 as amended upto date. Hardware or fitting shall conform to fig 4 of IS: 7935-1975 as amended upto date comprise fo 2 GI strips, 2 GI bolts and 2 nuts with spring washers.

48

9984

208

... More
Erection of L.T. brown glazed porcelain pin insulators of size 100mmx70mm conforming to type 1 fig 1 of IS: 1445/1977 with amendment 2 of Feb 1981 (second revision) as amended upto date. Minimum failing load shall be 3.5 KN with Forged GI pin conforming to IS 7935/1975 as amended upto date suitable for LT porcelain pin insulator type 1 conforming to fig 1 of IS: 1445/77 with amendment no 2 feb 1981, of size 100 x 70 mm. GI pin shall comprise of GI nut and spring washer and conform to fig No 2 of IS: 7935/1975. Minimum failing load of pin shall be 3.5 KN

5

865

173

... More
Erection of ACSR Conductor Hard drawn stranded aluminium conductor with galvanized steel wire reinforced conforming to IS: 398(PartII-96) amended upto date of the following sizes. WEASEL 6/1/2.59 (nominal aluminium area 30 Sq.mm.) (139 amp max at 45 °C) for line

0.3

2133

7110

... More
Erection of Earthing complete with chamber as per drg/ No. CEE/E-830. Each earthing should consist as follows a) 40 mm. Dia 2.5 mtr long, class B GI pipe 1 No. b)HDGI nut bolts, clamps 1 set, c)Brick masonary-0.108 Cu.mts d) PVC pipe 50mm dia- 0.2mtr e) Salt-20 Kgs f) Charcoal-20 Kgs g) Excavation-0.864 Cu. Mtr h) refilling-0.74 Cu.mtr as per drg. No.CEE/E-830.

6

14664

2444

... More
Erection of XPLE insulated single core unarmoured cable 50 mm2 for DP earthing.

55

3080

56

... More
Erection of AA"ANT" conductor

1.2

7954

6634

... More
Erection of AA"GNAT" conductor

1.12

6943

6183

... More
Erection of ACSR Conductor Hard drawn stranded aluminium conductor with galvanized steel wire reinforced conforming to IS: 398(PartII-96) amended upto date of the following sizes. WEASEL 6/1/2.59 (nominal aluminium area 30 Sq.mm.) (139 amp max at 45 °C) for DP earthing and line stringing for guarding

0.99

7024

7110

... More
Erection of MS Distribution box as per drg No. CEE/E-689 Revision No. 3 along with MCCB 400 A, Bus bar made out of Aluminium strips 40 x 10 mm, kit kat fuses for 4 feeder arrangement

1

8795

8795

... More
Erection of XLPE 1.1KV Armored single core unarmoured cable 185 mm²

48

8832

184

... More
Erection of XLPE 1.1KV 3 & 1/2 XLPE Armoured cable 120 mm²

36

6336

176

... More
Erection of Enamelled danger boards 11000 Volts ,250mm x 200mmm as per drg no. CEE/E-490

3

171

57

... More
Erection of Aluminium crimping Lugs shall conform to IS: 8309-1976 as amended upto date. Lugs shall be made of aluminium of grade IE of IS: 5082/1969 suitable for aluminium cable fo sizes 185 Sq.mm.

8

760

95

... More
Erection of Aluminium crimping Lugs shall conform to IS: 8309-1976 as amended upto date. Lugs shall be made of aluminium of grade IE of IS: 5082/1969 suitable for aluminium cable fo sizes 120 Sq.mm.

9

792

88

... More
Erection of Aluminium crimping Lugs shall conform to IS: 8309-1976 as amended upto date. Lugs shall be made of aluminium of grade IE of IS: 5082/1969 suitable for aluminium cable fo sizes 95 Sq.mm.

3

195

65

... More
Erection of Aluminium crimping Lugs shall conform to IS: 8309-1976 as amended upto date. Lugs shall be made of aluminium of grade IE of IS: 5082/1969 suitable for aluminium cable fo sizes50 Sq.mm.

45

2295

51

... More
Erection of FRP Fencing complete with Gate as epr specification for distribution transformer (size 4Mx3Mx2M) with Concreting for FRP Fencing supports with plinth (0.3x0.3x0.5)Cu.m.x12nos Each ratio 1;3;6

1

35000

35000

... More
Removing & Re-Erection of 100KVA tranformer centre

1

16525

16525.5

... More
Removing of 9 Mts long RCC pole

3

6612

2204

... More
Removing of 7.5 Mts long RCC pole

1

1844

1844.5

... More
Removing of 11KV GOAB switch 200 A, 3 Pole DP AB Switch

1

1985

1985.5

... More
Removing of 11KV 200 A H.G Fuse unit

1

1684

1684

... More
Removing of HDGI structural material

1

23

23.5

... More
Removing of 11 KV "V "shape cross arm with clamps & nut bolt for 9 mtr RCC pole

1

197

197.5

... More
Remmoving of 11 KV Cut point channel 1.3Mts long with clamps & nut bolt for 9 mtr RCC pole

1

274

274.5

... More
Removing of 11 KV disc Insuators 70KN with Metal Parts for 11KV disc insulator 70KN 3bolted type

3

562

187.5

... More
Removing of 11 KV Pin Insulator with GI Pin for 11KV pin insulator

3

228

76

... More
Removing of LT 4 pin cross arm of 75x40 channel with clamps & nut bolt for 9 mtr RCC pole

3

477

159

... More
Removing of LT 2-pin cross arm of 75x40 channel with clamps & nut bolts for 9 mtr RCC pole

3

433

144.5

... More
Removing of LT 4 pin cross arm of 75x40 channel with clamps & nut bolt for 7.5 mtr RCC pole

1

152

152.5

... More
Removing of LT 2-pin cross arm of 75x40 channel with clamps & nut bolts for 7.5 mtr RCC pole

1

138

138

... More
Removing of AA WEASEL Conductor

0.39

1386

3555

... More
Removing of AA ANT Conductor

0.71

2355

3317

... More
Removing of AA GNAT Conductor

0.71

2194

3091.5

... More
Removing of 3&1/2 C X95sqmm armoured cable

50

3725

74.5

... More
Removing of 3 &1/2 C X120 sqmm armoured cable

12

1056

88

... More
Removing & Re-Erection of AA ANT Conductor

0.28

2826

9951

... More
Removing & Re-Erection of AA GNAT Conductor

0.28

2633

9274.5

... More
Removing of MS Distribution box as per drg No. CEE/E-689 Revision No. 3 along with MCCB 400 A, Bus bar made out of Aluminium strips 40 x 10 mm, kit kat fuses for 4 feeder arrangement

1

4397

4397.5



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.