Electricity Department Tender

View complete overview of Goa Electricity Department Tender

Electricity Department Tender

Works
Agriculture or Forestry Works
Eprocure
Opening Date20 Feb 2025
Closing Date11 Mar 2025
Tender Amount₹ 13,61,622 
Notes
Download

Costs

  • EMD

    ₹ 27,232
  • Document Cost

    ₹ 1,500
  • Tender Fee

    ₹ 2,723

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
Supply of 11KV, 630 Amps, Outdoor, SF6 Ring Main Unit with two Load Break Switches and one Circuit Breaker conforming to International Standards and complete with Fault Passage Indicator other accessories & as per enclosed specifications.

1

565000

565000

... More
Supply of 11KV 3 phase indoor terminating kit complete, for 11 KV XLPE cable of size 3 x 185 sq.mm including sockets/lugs/connectors etc. for connecting RMU for main section side

2

7873

15746

... More
Supply of straight through joint complete for 11 KV XLPE cable of size 3 x 185 sq.mm including sockets/lugs/connectors etc.

1

27079

27079

... More
Supply of 11KV, 3 phase, Outdoor type, heat shrinkable end termination kit complete, for 11 KV XLPE cable of size 3 x 95sq.mm including sockets/lugs/connectors etc.

1

10152

10152

... More
Supply of 11KV, 3 phase, Indoor type, heat shrinkable end termination kit complete, for 11 KV XLPE cable of size 3 x 95sq.mm including sockets/lugs/connectors etc. for connecting RMU for main section side

1

6731

6731

... More
Supply and laying of fine river sand of approved quality for cushioning of HT underground cables laid by conventional Open Trenching Method.

1.24

2170

2686.46

... More
Supply of Cuddappa of size 600mm length x 250mm width and 1 inch thick as a protective cover for underground cables.

25

158

3950

... More
Supply of HDGI flat of size 25mm x 5mm for earthing of RMU's

10

116

1160

... More
Supply and laying of wire cut Bricks for 11KV Cable seperation.

50

9

475

... More
Supply of GI pipe,150mm dia

4

1681

6724

... More
Providing and laying in position cement concrete 1:2:4 (1 cement : 2 coarse sand: 4 graded granitic or basaltic stone aggregate 40 m nominal size for foundations of RMU's cement concrete for laying foundation for octagonal poles including the cost of centering, shuttering and muffing 0.5 m above ground and of diameter 0.5 m (Pit dimensions : 0.5 X 0.5 X 1.2 mts.)

0.5

5555

2777.5

... More
Supply & providing of Centering and shuttering including struttings, propping etc. and removal of formwork for a) Foundations, footings, bases of columns and mass concrete for RMU's

3.5

563

1970.5

... More
Supply & providing of 12 mm cement plaster 1:4 ( 1 cement: 4 fine sand) for foundations of RMU's

0.7

147

102.9

... More
Supply of 9.0 meters long R.C.C. Pole conforming to IS 785-1998 as amended upto date

5

8386

41930

... More
Supply of 7.5 meters long R.C.C. Pole conforming to IS 785-1998 as amended upto date.

2

6092

12184

... More
Supply & providing of Cement concrete in the ratio 1:2:4(1 cement: 2 Sand, 4 graded granite/basaltic, aggregate 20mm nominal size) including cost of centering, shuttering & muffing 0.4mts above the ground & properly curved

1.08

5555

5999.4

... More
Supply of HDGI 4 pin 'X' arm of 75 x 40 Channel.

6

1109

6654

... More
Supply of HDGI 2 pin 'X' arm of 75 x 40 Channel.

6

569

3414

... More
Supply of clamp L.A for 7.5mtr pole shall be hot dipped galvanized generally conforming to IS - 2633/72

4

184

736

... More
Supply of clamp L.A for 9 mtr pole shall be hot dipped galvanized generally conforming to IS - 2633/72

6

266

1596

... More
Supply of GI Xarm clamp SA for 9.0mts pole.shall be hot dipped galvanized generally conforming to IS - 2633/73

2

266

532

... More
Supply of HDGI stay clamps for RCC,Pole 9 mtr L.A.shall be hot dipped galvanized generally conforming to IS - 2633/72

2

491

982

... More
Supply of Insulator -(LT) Pin with HDG Pin.Pin.L.T.brown glazed porcelain pin insulators of size 100mm x 70mm conforming to type 1 fig 1 of IS:1445/1977 with amendment 2 of Feb.1981 (second revision) as amended upto date. Minimum failing load shall be 3.5kN. Insulators shall have marking and packing as prescribed in IS

8

263

2104

... More
Supply of Insulator -(LT) Shackle with HDG Metal Parts.L.T. brown glazed shackle insulators of size 100mm x 115mm conforming to fig.No.4 and type 2 of IS: 1445/77 as amended upto date. Minimum failing load shall be 16kN. Insulators shall have marking and packing as prescribed in IS

20

372

7440

... More
Supply of ACSR "WEASEL" of sizen( 6/1/2.59mm). Hard drawn stranded aluminium conductor with galvanised steel wire reinforced conforming to IS: 398(Pt-II/96) amended upto date.Packing and marking of drum will be as per IS:Conductor length shall be 1500 mtr. with tolerance of +/- 5%

0.13

33409

4176.13

... More
Supply of conductor-AA ANT, 2. 7/3.10 mm .Hard drawn stranded all aluminium conductor conforming to IS: 398(Pt-I/96) as amended upto date .Packing and marking of drum will be as per IS: Conductor length shall be 1500 mtr. with tolerance of +/- 5%

0.5

48086

24043

... More
Supply of conductor -AA GNAT,1. 7/2.21 mm,Hard drawn stranded all aluminium conductor conforming to IS: 398(Pt-I/96) as amended upto date .Packing and marking of drum will be as per IS: Conductor length shall be 1500 mtr. with tolerance of +/- 5%

0.39

25293

9914.86

... More
Supply of Anticlimbing device.Hot dip galvanized steel barbed wire type 4 conforming to IS:278/1962 as amended upto date and galvanization conforming to IS:4826/1979 as amended upto date

2

962

1924

... More
Supply of Enamelled danger board of size 250mm x 200mm

2

248

496

... More
Supply of Earthing with 40mm, 2.5 mm long GI pipe complete with chamber. Earthing pipe made of Hot Dip galvanized steel tube of heavy class, 40mm nominal bore conforming to IS 1239 Part 1 1990 as amended upto date and Hot Dip zinc coating shall conform to IS 4736-1968 as amended upto date

6

2730

16380

... More
Supply of GI stay set complete for 9.0 mts RCC pole.

3

4367

13101

... More
Supply of GI stay set complete for 7.5mt RCC pole.

1

4068

4068

... More
Supply of HDGI Structure Materials. shall be hot dipped galvanized

274

169

46306

... More
Supply of 11 KV GOAB switch with 200 A.12 KV rated voltage GOAB switches tilting type, outdoor, manually operated, triple pole, single break, conforming to IS: 9921-Part1 to V as amended upto date and detailed specifications enclosed herewith. Each set shall comprise of six pedestal and three tilting post insulators. Insulator should be factory cemented by the manufactures of the insulators and have minimum 320mm creepage distance and AB switches contacts shall be of copper/copper alloy

1

23535

23535

... More
Supply of 11 KV HG fuse unit ,200A

1

10450

10450

... More
Supply of 9 KV, 5A Lightning Arrestor, pole mounted.9 KV, 5 KA nominal discharge current Metal Oxide gapless distribution class lightning arrestor conforming to IEC-60099-4 and IS 3070 Part 3 1993 as amended upto date suitable for 11 KV 50 HZ effectively earthed neutral system with necessary mounting arrangements and connector suitable to connect ACSR conductor upto overall diameter 12.30 mm.The marking of the Lightning Arrestors shall be as per IS

3

3033

9099

... More
Supply of MS Distribution box complete.M. S. distribution box alongwith MCCB of 400Amps & 12 nos. of 200 Amps capacity Kit Kat Porcelain fuse carrier and base with extended terminals

1

63140

63140

... More
Supply of FRP Fencing complete with Gate as per specification for Distribution Transformer (Size 3Mx3Mx2M) with Concreting for FRP Fencing supports with plinth (0.3x0.3x0.5) Cu.m. x 12 nos. Each ratio 1:3:6

1

71167

71167

... More
Supply of Distribution Transformer Metering Unit, with DLMS protocol.

1

25688

25688

... More
Supply of XLPE unarmoured XLPE single core 120 sq.mm, 1.1KV grade.The armoured cable of sizes as required i.e. 120 Sq.mm that shall be suitably terminated at both the ends with appropriate sizes of Aluminum lugs duly crimped using a crimping tool. Appropriate sizes of G.I / Brass nut / bolts / washers shall be used for firmly connecting the same to the MCCB’s/Transformer L.T. Bushings/Outgoing LT feeder

48

164

7872

... More
Supply of XLPE unarmoured single core XLPE 185 sq.mm, 1.1KV grade.The armoured cable of sizes as required i.e.185 Sq.mm that shall be suitably terminated at both the ends with appropriate sizes of Aluminum lugs duly crimped using a crimping tool. Appropriate sizes of G.I / Brass nut / bolts / washers shall be used for firmly connecting the same to the MCCB’s/Transformer L.T. Bushings/Outgoing LT feeder

48

245

11760

... More
Supply of HDGI nuts & bolts.G.I. Hexagonal head bolts and hexagonal nuts conforming to IS 1363 part 1 to 3 1992 as amended upto date.The bolts and nuts shall be hot dip galvanized as per IS: 2629-1985 as amended upto date

11

228

2508

... More
Supply of Al.Crimping Lugs 120Sq.mm

8

54

432

... More
Supply of Al.Crimping Lugs 185 Sq.mm

4

78

312

... More
Supply of Al.Crimping Lugs 70Sq.mm

10

34

340

... More
Supply of Common Automatic Meter Reading (CAMR) Modems

1

6000

6000

... More
Erection Cost

-

-

-

... More
Erection, testing & Commissioning of 11KV, 3 core 185 sq.mm aluminium, XLPE insulated, flat wire armoured, 11 KV (Earthed) Cable, type A2XFY conforming I.S. 7098 PART 2 and carrying ISI MARK through conventional open trenching method in any type of soil including hard laterite

22.3

263

5864.9

... More
Laying of 11KV, 3 core 95 sq.mm aluminium, XLPE insulated, flat wire armoured, 11 KV (Earthed) Cable, type A2XFY conforming I.S. 7098 PART 2 and carrying ISI MARK through conventional open trenching method in any type of soil including hard lateriteas per enclosed specifications.

25.25

199

5024.75

... More
Erection, testing & commissioning of 11KV, 630 Amps, Outdoor, SF6 Ring Main Unit with two Load Break Switches and one Circuit Breaker conforming to International Standards and complete with Fault Passage Indicator other accessories& as per enclosed specifications.

1

9720

9720

... More
Erection, testing & commissioining of 11KV 3 phase indoor terminating kit complete, for 11 KV XLPE cable of size 3 x 185 sq.mm including sockets/lugs/connectors etc. for connecting RMU for main section side

2

2548

5096

... More
Erection,testing & commissioning of straight through joint complete for 11 KV XLPE cable of size 3 x 185 sq.mm including sockets/lugs/connectors etc.

1

3450

3450

... More
Erection,testing & commissioning of 11KV, 3 phase, Outdoor type, heat shrinkable end termination kit complete, for 11 KV XLPE cable of size 3 x 95sq.mm including sockets/lugs/connectors etc.

1

2648

2648

... More
Erection,testing & commissioning of 11KV, 3 phase, Indoor type, heat shrinkable end termination kit complete, for 11 KV XLPE cable of size 3 x 95sq.mm including sockets/lugs/connectors etc. for connecting RMU for main section side

1

2538

2538

... More
Excavation in any type of soil including hard laterite soil by mechanical means( hydraulic excavator)/manual means for laying of HT/ LT cables of various sizes including excavation for equipment foundations i.e for RMU's including getting out the excavated soil and disposal of surplus excavated soil.

9.68

468

4527.9

... More
Refilling of excavated soil in the foundations, trenches etc. with avialable excavated earth in layers not exceeding 20 cm depth, cosolidating each layer by ramming and watering lead upto 50 M and all lifts and disposal of surplus earth in cable trenches and foundations of equipments.

7.69

120

922.2

... More
Laying of Cuddappa of size 600mm length x 250mm width and 1 inch thick as a protective cover for underground cables.

25

67

1675

... More
Providing of HDGI flat of size 25mm x 5mm for earthing of RMU's

10

48

480

... More
Laying of GI pipe,150mm dia

4

182

728

... More
Erection of 9.0 meters long R.C.C. Pole conforming to IS 785-1998 as amended upto date

5

5900

29500

... More
Erection of 7.5 meters long R.C.C. Pole conforming to IS 785-1998 as amended upto date.

2

5200

10400

... More
Fixing of HDGI 4 pin 'X' arm of 75 x 40 Channel.

6

261

1566

... More
Fixing of HDGI 2 pin 'X' arm of 75 x 40 Channel.

6

232

1392

... More
Providing of clamp L.A for 7.5mtr pole shall be hot dipped galvanized generally conforming to IS - 2633/72

4

32

128

... More
Providing of clamp L.A for 9 mtr pole shall be hot dipped galvanized generally conforming to IS - 2633/72

6

45

270

... More
Fixing of GI Xarm clamp SA for 9.0mts pole.shall be hot dipped galvanized generally conforming to IS - 2633/73

2

45

90

... More
Fixing of HDGI stay clamps for RCC,Pole 9 mtr L.A.shall be hot dipped galvanized generally conforming to IS - 2633/72

2

79

158

... More
Fixing of Insulator -(LT) Pin with HDG Pin.Pin.L.T.brown glazed porcelain pin insulators of size 100mm x 70mm conforming to type 1 fig 1 of IS:1445/1977 with amendment 2 of Feb.1981 (second revision) as amended upto date. Minimum failing load shall be 3.5kN. Insulators shall have marking and packing as prescribed in IS

8

173

1384

... More
Fixing of Insulator -(LT) Shackle with HDG Metal Parts.L.T. brown glazed shackle insulators of size 100mm x 115mm conforming to fig.No.4 and type 2 of IS: 1445/77 as amended upto date. Minimum failing load shall be 16kN. Insulators shall have marking and packing as prescribed in IS

20

208

4160

... More
Stringing of ACSR "WEASEL" of sizen( 6/1/2.59mm). Hard drawn stranded aluminium conductor with galvanised steel wire reinforced conforming to IS: 398(Pt-II/96) amended upto date.Packing and marking of drum will be as per IS:Conductor length shall be 1500 mtr. with tolerance of +/- 5%

0.13

11000

1375

... More
Stringing of conductor-AA ANT, 2. 7/3.10 mm .Hard drawn stranded all aluminium conductor conforming to IS: 398(Pt-I/96) as amended upto date .Packing and marking of drum will be as per IS: Conductor length shall be 1500 mtr. with tolerance of +/- 5%

0.5

10300

5150

... More
Stringing of conductor -AA GNAT,1. 7/2.21 mm,Hard drawn stranded all aluminium conductor conforming to IS: 398(Pt-I/96) as amended upto date .Packing and marking of drum will be as per IS: Conductor length shall be 1500 mtr. with tolerance of +/- 5%

0.39

9100

3567.2

... More
Fixing of Anticlimbing device.Hot dip galvanized steel barbed wire type 4 conforming to IS:278/1962 as amended upto date and galvanization conforming to IS:4826/1979 as amended upto date

2

175

350

... More
Fixing of Enamelled danger board of size 250mm x 200mm

2

57

114

... More
Providing of Earthing with 40mm, 2.5 mm long GI pipe complete with chamber. Earthing pipe made of Hot Dip galvanized steel tube of heavy class, 40mm nominal bore conforming to IS 1239 Part 1 1990 as amended upto date and Hot Dip zinc coating shall conform to IS 4736-1968 as amended upto date

6

2444

14664

... More
Erection of GI stay set complete for 9.0 mts RCC pole.

3

2466

7398

... More
Erection of GI stay set complete for 7.5mt RCC pole.

1

2404

2404

... More
Fixing of HDGI Structure Materials. shall be hot dipped galvanized

274

47

12878

... More
Erection,testing & commissioning of 11 KV GOAB switch with 200 A.12 KV rated voltage GOAB switches tilting type, outdoor, manually operated, triple pole, single break, conforming to IS: 9921-Part1 to V as amended upto date and detailed specifications enclosed herewith. Each set shall comprise of six pedestal and three tilting post insulators. Insulator should be factory cemented by the manufactures of the insulators and have minimum 320mm creepage distance and AB switches contacts shall be of copper/copper alloy

1

3971

3971

... More
Erection,testing & Commissioning of 11 KV HG fuse unit ,200A

1

3368

3368

... More
Erection of 9 KV, 5A Lightning Arrestor, pole mounted.9 KV, 5 KA nominal discharge current Metal Oxide gapless distribution class lightning arrestor conforming to IEC-60099-4 and IS 3070 Part 3 1993 as amended upto date suitable for 11 KV 50 HZ effectively earthed neutral system with necessary mounting arrangements and connector suitable to connect ACSR conductor upto overall diameter 12.30 mm.The marking of the Lightning Arrestors shall be as per IS

3

174

522

... More
Erection of MS Distribution box complete.M. S. distribution box alongwith MCCB of 400Amps & 12 nos. of 200 Amps capacity Kit Kat Porcelain fuse carrier and base with extended terminals

1

8795

8795

... More
Erection of Distribution Transformer 100 KVA.11/0.433KV, 50HZ, outdoor type, oil immersed, core type, Oil Natural Air Natural Cool type, Delta Star Dy11 aluminium wound, distribution transformer (without taps) . Level-II losses, Alluminium winding, with bimetallic terminal connectors. Energy efficiency level-II as per IS :1180(part-I):2014

1

11017

11017

... More
Erection of FRP Fencing complete with Gate as per specification for Distribution Transformer (Size 3Mx3Mx2M) with Concreting for FRP Fencing supports with plinth (0.3x0.3x0.5) Cu.m. x 12 nos. Each ratio 1:3:6

1

33667

33667

... More
Fixing of Distribution Transformer Metering Unit, with DLMS protocol.

1

1072

1072

... More
Laying,testing & commissioning of XLPE unarmoured XLPE single core 120 sq.mm, 1.1KV grade.The armoured cable of sizes as required i.e. 120 Sq.mm that shall be suitably terminated at both the ends with appropriate sizes of Aluminum lugs duly crimped using a crimping tool. Appropriate sizes of G.I / Brass nut / bolts / washers shall be used for firmly connecting the same to the MCCB’s/Transformer L.T. Bushings/Outgoing LT feeder

48

95

4560

... More
Laying ,testing & commissioning of XLPE unarmoured single core XLPE 185 sq.mm, 1.1KV grade.The armoured cable of sizes as required i.e.185 Sq.mm that shall be suitably terminated at both the ends with appropriate sizes of Aluminum lugs duly crimped using a crimping tool. Appropriate sizes of G.I / Brass nut / bolts / washers shall be used for firmly connecting the same to the MCCB’s/Transformer L.T. Bushings/Outgoing LT feeder

48

170

8160

... More
Providing of HDGI nuts & bolts.G.I. Hexagonal head bolts and hexagonal nuts conforming to IS 1363 part 1 to 3 1992 as amended upto date.The bolts and nuts shall be hot dip galvanized as per IS: 2629-1985 as amended upto date

11

30

330

... More
Providing of Al.Crimping Lugs 120Sq.mm

8

88

704

... More
Providing of Al.Crimping Lugs 185 Sq.mm

4

95

380

... More
Providing of Al.Crimping Lugs 70Sq.mm

10

59

590



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements

Past Bidders
This list is curated from the bidders of the similar tenders in the past

Unlock the Tender details for free
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.