Summary

Work Of Laying Of 11 Kv Underground Cable At Different Locations 1) Searock Dtc To Machado Cove Dtc 2) Chaitanya Dtc To Kamat Villa Switch 3) Gera Tlbs To Samarth 4) Casino Tlbs To Pinto Tlbs 5) Relocation Of Meredian And Models Feeder Along Nio Circ

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
Earthwork in excavation by mechanical means( hydraulic excavator)/manual means in foundation pipeline trenches drain( not exceeding 1.5 mt in width or 10 sq.m on plan) including dressing of sides and ramming of bottoms, lift upto 1.5 m including getting out the excavated soil and disposl of surplus excavated soil as directed within a lead of 50 m(a) for laying of HT cables of various sizes in all kinds of soil, hard rock etc. The trench lengths are as follows:

-

-

-

... More
All types of Ordinary rock including all types of laterite rock, blasting prohibited (0.45*1.1*1000)

495

-

-

... More
Hard rock where blasting prohibited (0.45*1.1*485)

240.07

-

-

... More
Refilling the pipeline/foundation trenches plinth sides, foundation etc. with available excavated earth in layers not exceeding 20 cm depth consolidating each layer ramming and watering lead upto 50 M and all lifts and disposal of surplus earth as directed by Engineer in Charge. (0.45*0.9*1485)

601.43

-

-

... More
Supply of Underground cable protective cover as per specs. The concrete slab shall be machine made using semi dry concrete that is batched in a fully automatic PLC controlled concrete batching plant and cast in a fully automatic "Vibro-press" machine with a high vibration frequency and hydraulic presuure of 40 MT, the size of the slab shall be 480mm*250mm*50mm and the concrete grade shall be M30 Adhring to IS 456l:2000 and shall have a minimum crushing strength of 30 N/mm2 (28 days strength) when tested.

3094

417690

135

... More
Supplying and laying of sand. (0.45*0.2*2550)

133.65

290020

2170

... More
Disposal of surplus excavated soil / material by mechanical transportation including loading and unloading, stacking/levelling as directed within a distance of 2500mts (0.45*0.2*1485

133.65

16815

125.82

... More
Supply of indoor cable end termination kit for 11KV 300 mm2 XLPE 3 core heat shrinkable kit

15

132600

8840

... More
Supply of indoor cable end termination kit for 11KV 150mm2 XLPE 3 core heat shrinkable kit

3

23619

7873

... More
Supply of indoor cable end termination kit for 11KV 95mm2 XLPE 3 core heat shrinkable kit

3

20193

6731

... More
Supply of outdoor cable end termination kit for 11KV 95mm2 XLPE 3 core heat shrinkable kit

3

30456

10152

... More
Supply of H. S. 11KV straight through joint 3 core 150 Sq mm

3

81237

27079

... More
Supply of H. S. 11KV straight through joint 3 core 300 Sq mm

6

177354

29559

... More
Supply of 3 WAY RMU, 11KV, 630A, 21 kA 3Sec, SF6 Outdoor RMU – 3LBS Extensible/Non Extensible Three (3) Motor operated load break switches (LBSs) with Manual operated earthing switches in SF6 SCADA Compatible and base channel. Battery charger along with batteries required for Electrical operations of RMU is in the scope of the Bidder. Each module shall consist of VPIS, FPI in LBS Module (N-1) but not less than 1 no’s per RMU. Suitable arrangement for mounting FRTU , modem or Ethernet Switch/LIU along with battery, battery charger shall be provided in RMU.

1

544000

544000

... More
Providing and laying in position cement concrete 1:2:4 ( 1- cement , 2- Coarse sand 3-garded garnite aggregate 40m nominal size ) excluding the rate of finishing (1*1*0.7)

0.7

3888

5555

... More
Providing 12 mm cement plaster 1:4 ( cement 4: fine sand )

1

147

147

... More
Supply of 3C X 300 sqmm XLPE cable

1950

4559100

2338

... More
Supply of 3C X 150 sqmm XLPE cable

478

696446

1457

... More
Supply of 3C X 95 sqmm XLPE cable

30

33810

1127

... More
Supply of 11Kv Route Marker (for entire route length)

20

10560

528

... More
Supply of Warning tape

0.7

10500

15000

... More
Earthing complete with 40mm GI Pipe, 2.5 mts long alongwith 20 kgs each salt, charcoal complete with brick masonary.

2

8856

4428

... More
Supply of GI Flat 25 x 5 mm.including supply and fixing of required quantity of HDGI nutbolts and washers for earthing of all equipment and every fifth streetlight pole.

5

580

116

... More
Laterite Masonary works Rubble packing with hard laterite stone under floors including watering ramming and consolidating etc. in pipeline trenches and other foundations complete for: (d) Single Circuit 11KV cable trench (0.2x0.7x800)

112

247632

2211

... More
Supply of Medium duty class B HDGI pipe for road/nullas crossing of nominal diameter 150mm

40

67240

1681

... More
ERECTION, TESTING AND COMMISSIONING

-

-

-

... More
Open Trenching method:- Excavation of pit, laying of protective covers, RCC hume pipe, earthing, foundations for equipments etc

-

-

-

... More
Earthwork in excavation by mechanical means( hydraulic excavator)/manual means in foundation pipeline trenches drain( not exceeding 1.5 mt in width or 10 sq.m on plan) including dressing of sides and ramming of bottoms, lift upto 1.5 m including getting out the excavated soil and disposl of surplus excavated soil as directed within a lead of 50 m(a) for laying of HT cables of various sizes in all kinds of soil, hard rock etc. The trench lengths are as follows:

-

-

-

... More
All types of Ordinary rock including all types of laterite rock, blasting prohibited (0.45*1.1*1000)

495

231660

468

... More
Hard rock where blasting prohibited (0.45*1.1*485)

240.07

183173

763

... More
Refilling the pipeline/foundation trenches plinth sides, foundation etc. with available excavated earth in layers not exceeding 20 cm depth consolidating each layer ramming and watering lead upto 50 M and all lifts and disposal of surplus earth as directed by Engineer in Charge. (0.45*0.9*1485)

601.43

72171

120

... More
E,T&C of Underground cable protective cover as per specs. The concrete slab shall be machine made using semi dry concrete that is batched in a fully automatic PLC controlled concrete batching plant and cast in a fully automatic "Vibro-press" machine with a high vibration frequency and hydraulic presuure of 40 MT, the size of the slab shall be 480mm*250mm*50mm and the concrete grade shall be M30 Adhring to IS 456l:2000 and shall have a minimum crushing strength of 30 N/mm2 (28 days strength) when tested.

3094

185640

60

... More
Supplying and laying of sand. (0.45*0.2*2550)

133.65

-

-

... More
Disposal of surplus excavated soil / material by mechanical transportation including loading and unloading, stacking/levelling as directed within a distance of 2500mts (0.45*0.2*1485

133.65

-

-

... More
E,T&C of indoor cable end termination kit for 11KV 300 mm2 XLPE 3 core heat shrinkable kit

15

38220

2548

... More
E,T&C of indoor cable end termination kit for 11KV 150mm2 XLPE 3 core heat shrinkable kit

3

7644

2548

... More
E,T&C of indoor cable end termination kit for 11KV 95mm2 XLPE 3 core heat shrinkable kit

3

7614

2538

... More
E,T&C of outdoor cable end termination kit for 11KV 95mm2 XLPE 3 core heat shrinkable kit

3

7944

2648

... More
E,T&C of H. S. 11KV straight through joint 3 core 150 Sq mm

3

10350

3450

... More
E,T&C of H. S. 11KV straight through joint 3 core 300 Sq mm

6

22278

3713

... More
E,T&C of 3 WAY RMU, 11KV, 630A, 21 kA 3Sec, SF6 Outdoor RMU – 3LBS Extensible/Non Extensible Three (3) Motor operated load break switches (LBSs) with Manual operated earthing switches in SF6 SCADA Compatible and base channel. Battery charger along with batteries required for Electrical operations of RMU is in the scope of the Bidder. Each module shall consist of VPIS, FPI in LBS Module (N-1) but not less than 1 no’s per RMU. Suitable arrangement for mounting FRTU , modem or Ethernet Switch/LIU along with battery, battery charger shall be provided in RMU.

1

9720

9720

... More
Providing and laying in position cement concrete 1:2:4 ( 1- cement , 2- Coarse sand 3-garded garnite aggregate 40m nominal size ) excluding the rate of finishing (1*1*0.7)

0.7

-

-

... More
Providing 12 mm cement plaster 1:4 ( cement 4: fine sand )

1

-

-

... More
E,T&C of 3C X 300 sqmm XLPE cable

1950

666900

342

... More
E,T&C of 3C X 150 sqmm XLPE cable

478

118544

248

... More
E,T&C of 3C X 95 sqmm XLPE cable

30

5970

199

... More
E,T&C of 11Kv Route Marker (for entire route length)

20

5120

256

... More
E,T&C of Warning tape

0.7

-

-

... More
Earthing complete with 40mm GI Pipe, 2.5 mts long alongwith 20 kgs each salt, charcoal complete with brick masonary.

2

5330

2665

... More
E,T&C of GI Flat 25 x 5 mm.including supply and fixing of required quantity of HDGI nutbolts and washers for earthing of all equipment and every fifth streetlight pole.

5

240

48

... More
Laterite Masonary works Rubble packing with hard laterite stone under floors including watering ramming and consolidating etc. in pipeline trenches and other foundations complete for: (d) Single Circuit 11KV cable trench (0.2x0.7x800)

112

-

-

... More
E,T&C of Medium duty class B HDGI pipe for road/nullas crossing of nominal diameter 150mm

40

7280

182

... More
SCHEDULE 2

-

-

-

... More
Supply/Material

-

-

-

... More
Supply of 3C X 300 sqmm XLPE cable

500

1169000

2338

... More
Supply of 3C X 185 sqmm XLPE cable

300

400200

1334

... More
Supply of H. S. 11KV straight through joint 3 core 300 Sq mm

1

29559

29559

... More
Supply of indoor cable end termination kit for 11KV 300 mm2 XLPE 3 core heat shrinkable kit

5

44200

8840

... More
Supply of H. S. 11KV straight through joint 3 core 185 Sq mm

1

27079

27079

... More
Supply of indoor cable end termination kit for 11KV 185mm2 XLPE 3 core heat shrinkable kit

2

15746

7873

... More
Earthwork excavation in foundations trenches (not exceeding 1.5mts in width or 10mm² on plan) including opening of roads, chamber/pavements & soiling , ramming, levelling of bottoms, making free from stones including removing out the excavated soil/material as directed within a lead of 40mts in laterite rock soil (1.1x0.45x10)

4.95

-

-

... More
Back Filling up of available excavated earth (excluding rock/stones) in trenches, plinth, sides, foundations etc. in layer not exceeding 0.2 mtrs. depth consolidation each deposited layer by ramming and watering (0.7x0.45x10)

3.15

-

-

... More
Disposal of surplus excavated soil/material by mechanical transportation including loading, unloading, starting leveling as directed up to a distance of 2.5 km

0.9

113

125.82

... More
Supply of Underground cable protective cover as per specs. The concrete slab shall be machine made using semi dry concrete that is batched in a fully automatic PLC controlled concrete batching plant and cast in a fully automatic "Vibro-press" machine with a high vibration frequency and hydraulic presuure of 40 MT, the size of the slab shall be 480mm*250mm*50mm and the concrete grade shall be M30 Adhring to IS 456l:2000 and shall have a minimum crushing strength of 30 N/mm2 (28 days strength) when tested.

21

2835

135

... More
Supply & laying of sand.

0.9

1953

2170

... More
Laterite Masonary works Rubble packing with hard laterite stone under floors including watering ramming and consolidating etc. in pipeline trenches and other foundations complete for: (d) Double Circuit 11KV cable trench (0.2x0.9x1.0)

1.8

3979

2211

... More
ERECTION, TESTING AND COMMISSIONING

-

-

-

... More
E,T&C of 3C X 300 sqmm XLPE cable

500

171000

342

... More
E,T&C of 3C X 185 sqmm XLPE cable

300

78900

263

... More
E,T&C of H. S. 11KV straight through joint 3 core 300 Sq mm

1

3713

3713

... More
E,T&C of indoor cable end termination kit for 11KV 300 mm2 XLPE 3 core heat shrinkable kit

5

12740

2548

... More
E,T&C of H. S. 11KV straight through joint 3 core 185 Sq mm

1

3450

3450

... More
E,T&C of indoor cable end termination kit for 11KV 185mm2 XLPE 3 core heat shrinkable kit

2

5096

2548

... More
Earthwork excavation in foundations trenches (not exceeding 1.5mts in width or 10mm² on plan) including opening of roads, chamber/pavements & soiling , ramming, levelling of bottoms, making free from stones including removing out the excavated soil/material as directed within a lead of 40mts in laterite rock soil (1.1x0.45x10)

4.95

3776

763

... More
Back Filling up of available excavated earth (excluding rock/stones) in trenches, plinth, sides, foundations etc. in layer not exceeding 0.2 mtrs. depth consolidation each deposited layer by ramming and watering (0.7x0.45x10)

3.15

378

120

... More
Disposal of surplus excavated soil/material by mechanical transportation including loading, unloading, starting leveling as directed up to a distance of 2.5 km

0.9

-

-

... More
E,T&C of Underground cable protective cover as per specs. The concrete slab shall be machine made using semi dry concrete that is batched in a fully automatic PLC controlled concrete batching plant and cast in a fully automatic "Vibro-press" machine with a high vibration frequency and hydraulic presuure of 40 MT, the size of the slab shall be 480mm*250mm*50mm and the concrete grade shall be M30 Adhring to IS 456l:2000 and shall have a minimum crushing strength of 30 N/mm2 (28 days strength) when tested.

21

1260

60

... More
Supply & laying of sand.

0.9

-

-

... More
Laterite Masonary works Rubble packing with hard laterite stone under floors including watering ramming and consolidating etc. in pipeline trenches and other foundations complete for: (d) Double Circuit 11KV cable trench (0.2x0.9x1.0)

1.8

-

-



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.