Electricity Department Tender

View complete overview of Goa Electricity Department Tender

Electricity Department Tender

Works
Energy, Oil and Gas
Eprocure
Opening Date26 Dec 2024
Closing Date13 Jan 2025
Tender Amount₹ 5,78,54,435 
Notes
Download

Costs

  • EMD

    ₹ 11,57,089
  • Document Cost

    ₹ 1,500
  • Tender Fee

    ₹ 6,000

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
Supply and providng of Sand for cushioning of HT underground cables. (Dimesions : - 0.2*0.4*6750)

540

2170

1171800

... More
Supply of 11KV, 3 core 300 sq.mm A2XFY Aluminium Armoured XLPE Cable through conventional open trenching method in any type of soil including hard laterite.

6309

2595

16371855

... More
Supply of straight through joint for 300sq.mm cable

16

29559

472944

... More
Supply of underground cable protective cover as per specification as given below: The concrete slab shall be machine made using semi dry concrete that is batched in a fully automatic PLC controlled concrete batching plant and cast in a fully automatic "Vibro Press" machine with a high vibration frequency and hydraulic pressure of 40 MT, the size of the slab shall be 480mm x 250 mm x 50 mm, (+/- 2 mm) and the concrete grade shall be M30 adhering to IS 456:2000 and shall have a minimum crushing strength of 30 N/mm2 (28 days strength) when tested.

15363

135

2074005

... More
Supply and laying of Warning tape.

6.15

15000

92250

... More
Supply of 3 way RMU ,11KV ,630 A,21KA, 3Sec,SF6 outdoor RMU -2LBS +1CB Extensible/Non-Extensible Two (2) Motor operated load break switches (LBSs) with Manual operated earthing switches in SF6 and One (1) vacuum circuit breaker with Electrical closing and tripping along with disconnector and earthing switches SCADA Compatible and base channel. Battery charger along with batteries required for Electrical operations of RMU is in the scope of the Bidder. Each module shall consist of VPIS, FPI in LBS Module (N-1) but not less than 1 no’s per RMU. Suitable arrangement for mounting FRTU, modem or Ethernet Switch/LIU along with battery, battery charger shall be provided in RMU. (Without auxiliary PT)

25

620750

15518750

... More
Supply of 3 WAY RMU ,11KV ,630 A,21KA, 3Sec,SF6 outdoor RMU -3LBS a. Extensible/Non Extensible Three (3) Motor operated load break switches (LBSs) with Manual operated earthing switches in SF6 SCADA Compatible and base channel. Battery charger along with batteries required for Electrical operations of RMU is in the scope of the Bidder. Each module shall consist of VPIS, FPI in LBS Module (N-1) but not less than 1 no’s per RMU. Suitable arrangement for mounting FRTU , modem or Ethernet Switch/LIU along with battery, battery charger shall be provided in RMU. With auxiliary PT as per specification shall be provided in RMU.

5

720000

3600000

... More
Supply of 4 way RMU, 11KV, 630A, 21 kA, 3 Sec, SF6 Outdoor RMU-4LBS (With auxiliary PT)

2

917000

1834000

... More
Supply of 11KV, 3 core 95sq.mm A2XFY Aluminium Armoured XLPE Cable through conventional open trenching method in any type of soil including hard laterite.

260

1240

322400

... More
Supply of 11KV 3 phase indoor terminating kit to be used with cables - 300sq.mm.

75

8840

663000

... More
Supply of 11KV 3 phase outdoor terminating kit to be used with cables - 300sq.mm.

2

11667

23334

... More
Supply of 11KV 3 phase indoor terminating kit to be used with cables - 95sq.mm.

26

6731

175006

... More
Supply of 11KV 3 phase outdoor terminating kit including sockets at 11KV end of DT to be used with cables As per - 95sq.mm.

26

10152

263952

... More
Supply of RCC Cable Route marker ( 400x 900x 100 MM)

70

528

36960

... More
Supply of Earthing complete with 40mm GI Pipe, 2.5 mts long alongwith Batonite complete.

144

6632

955008

... More
Supply of XLPE Single Core unarmoured XLPE 240 sq mm 1.1.KV grade

510

366

186660

... More
Supply of Compression type Aluminium tubulae terminal ends (lugs) of size 240sqmm

111

94

10434

... More
Supply of XLPE Single Core unarmoured XLPE 150 sq mm 1.1.KV grade

870

201

174870

... More
Supply of Compression type Aluminium tubulae terminal ends (lugs) of size 150sqmm

147

62

9114

... More
Supply of Distribution Boxes(M.S) with 200Amps MCCB & Kit-Kat fuses,As per drawing No. CEE/E-689rEVISION No.3alongwith 12 nos of 200A kitkat Porcelain fuse carrier and bAse with extended terminals confirming in gerneral to drawing No. EE-II/7/2002 with 1 no. moulded cAse circuit breaker (MCCB),415 v, AC, 50Hz with extended terminals confirming to IS 13947-2 As amended upto date .

18

48387

870966

... More
Supply of FRP Fencing complete with Gate As per specification for Distribution transformer (size 4Mx3Mx2M) with concreting for FRP Fencing supports with plinth (0.3x0.3x.5)Cu.mx12 nos .Each ratio 1:3:6

18

76667

1380006

... More
Supply of HDGI flat of size 25mm x 5mm for earthing [Galvanising should be hot dipped Galvanised as per IS:2629/66, minimum Zinc coating of 1000 gms/sq.mtr, 140 Microns DFT), suitable for high salinity coastal areas].

510

116

59160

... More
Supply and spreading of 40/20mm stone aggreggate

57.4

2217

127255.8

... More
Supply of Control cable , PVC COPPER CABLE (Armoured ) of size 4cx2.5sqmm armoured cable

240

242

58080

... More
Erection

-

-

-

... More
Earthwork in excavation by mechanical means (hydraulic excavator)/manual means over are As (exceeding 30 cm in depth, 1.5 m in width As well As 10 sq.m on plan) including disposal of excavated earth lead upto 50 m and lift upto 1.5m disposed earth to be leveled and neatly dressed including providing barricading, danger lighting guarding As directed in : Hard Soil (Dimensions : - 1.1*0.4*6750) for TRENCH AND RMU

2970

763

2266110

... More
Laying/providing of RCC Hume Pipe 100mm dia NP2 pipe As per GSR202(Roads) item nn 1910 ,with required no. of collars for road crossing .

330

77

25410

... More
Erection/ laying of GI Pipe 100mm, clAss B for nalla crossing and for cable rising .

340

92

31280

... More
Laying, Testing and Commissioningof 11KV, 3 core 300 sq.mm A2XFY Aluminium Armoured XLPE Cable through conventional open trenching method in any type of soil including hard laterite.

6309

342

2157678

... More
Erection, Testing and Commissioning erection of straight through joint for 300sq.mm cable

16

3713

59408

... More
Erection/ laying of underground cable protective cover as per specification as given below: The concrete slab shall be machine made using semi dry concrete that is batched in a fully automatic PLC controlled concrete batching plant and cast in a fully automatic "Vibro Press" machine with a high vibration frequency and hydraulic pressure of 40 MT, the size of the slab shall be 480mm x 250 mm x 50 mm, (+/- 2 mm) and the concrete grade shall be M30 adhering to IS 456:2000 and shall have a minimum crushing strength of 30 N/mm2 (28 days strength) when tested.

15363

60

921780

... More
Refilling the pipeline/foundation trenches plinth sides, foundation etc. with available excavated earth in layers not exceeding 20 cm depth consolidating each layer ramming and watering lead upto 50 M and all lifts and disposal of surplus earth As directed by Engineer in Charge (Dimesions : - 0.9*0.4*6750)

2430

120

291600

... More
Disposal of earth at a distance of 3000 mts (Dimesions : - 0.2*0.4*6750)

540

125

67942.8

... More
Erection, Testing and Commissioning of 3 way RMU ,11KV ,630 A,21KA, 3Sec,SF6 outdoor RMU -2LBS +1CB Extensible/Non-Extensible Two (2) Motor operated load break switches (LBSs) with Manual operated earthing switches in SF6 and One (1) vacuum circuit breaker with Electrical closing and tripping along with disconnector and earthing switches SCADA Compatible and base channel. Battery charger along with batteries required for Electrical operations of RMU is in the scope of the Bidder. Each module shall consist of VPIS, FPI in LBS Module (N-1) but not less than 1 no’s per RMU. Suitable arrangement for mounting FRTU, modem or Ethernet Switch/LIU along with battery, battery charger shall be provided in RMU. (Without auxiliary PT)

25

9720

243000

... More
Erection, Testing and Commissioning of 3 WAY RMU ,11KV ,630 A,21KA, 3Sec,SF6 outdoor RMU -3LBS a. Extensible/Non Extensible Three (3) Motor operated load break switches (LBSs) with Manual operated earthing switches in SF6 SCADA Compatible and base channel. Battery charger along with batteries required for Electrical operations of RMU is in the scope of the Bidder. Each module shall consist of VPIS, FPI in LBS Module (N-1) but not less than 1 no’s per RMU. Suitable arrangement for mounting FRTU , modem or Ethernet Switch/LIU along with battery, battery charger shall be provided in RMU. With auxiliary PT as per specification shall be provided in RMU.

5

9720

48600

... More
Erection, Testing and Commissioning of 4 way RMU, 11KV, 630A, 21 kA, 3 Sec, SF6 Outdoor RMU-4LBS (With auxiliary PT)

2

9720

19440

... More
Laying, Testing and Commissioning of 11KV, 3 core 95sq.mm A2XFY Aluminium Armoured XLPE Cable through conventional open trenching method in any type of soil including hard laterite.

260

199

51740

... More
Erection, Testing and Commissioning of 11KV 3 phase indoor terminating kit to be used with cables - 300sq.mm.

75

2548

191100

... More
Erection, Testing and Commissioning of 11KV 3 phase outdoor terminating kit to be used with cables - 300sq.mm.

2

2718

5436

... More
Erection, Testing and Commissioning of 11KV 3 phase indoor terminating kit to be used with cables - 95sq.mm.

26

2538

65988

... More
Erection, Testing and Commissioning of 11KV 3 phase outdoor terminating kit including sockets at 11KV end of DT to be used with cables 95sq.mm.

26

2648

68848

... More
Laying of RCC Cable Route marker ( 400x900x100 MM)

70

256

17920

... More
Providing of Earthing complete with 40mm GI Pipe, 2.5 mts long alongwith Batonite complete.

144

3141

452304

... More
Erection, Testing and Commissioning of XLPE Single Core unarmoured XLPE 240 sq mm 1.1.KV grade

510

200

102000

... More
Providing of Compression type Aluminium tubulae terminal ends (lugs) of size 240sqmm

111

101

11211

... More
Erection, Testing and Commissioning of XLPE Single Core unarmoured XLPE 150 sq mm 1.1.KV grade

870

138

120060

... More
Providing of Compression type Aluminium tubulae terminal ends (lugs) of size 150sqmm

147

95

13965

... More
Erection, Testing and Commissioning of Distribution Boxes(M.S) with 200Amps MCCB & Kit-Kat fuses,As per drawing No. CEE/E-689rEVISION No.3alongwith 12 nos of 200A kitkat Porcelain fuse carrier and bAse with extended terminals confirming in gerneral to drawing No. EE-II/7/2002 with 1 no. moulded cAse circuit breaker (MCCB),415 v, AC, 50Hz with extended terminals confirming to IS 13947-2 As amended upto date .

18

4687

84366

... More
Erection, Testing and Commissioning of FRP Fencing complete with Gate As per specification for Distribution transformer (size 4Mx3Mx2M) with concreting for FRP Fencing supports with plinth (0.3x0.3x.5)Cu.mx12 nos .Each ratio 1:3:6

18

40000

720000

... More
Erection of HDGI flat of size 25mm x 5mm for earthing.

510

48

24480

... More
Erection, Testing and Commissioning of Control cable , PVC COPPER CABLE (Armoured ) of size 4cx2.5sqmm armoured cable

240

49

11760

... More
Dismantling

-

-

-

... More
Removing and refixing of DTC Metering panel

18

2484

44712

... More
Removing and refixing of 4cx2.5sqmm armoured cable

240

73

17640

... More
Removing and re-hoisting of the existing Transformer of capacity 160KVA/ 200KVA

18

23457

422226

... More
Removing Of Old RCC Poles 9 Mts Long Pole

107

2950

315650

... More
Removing Of Old RCC Poles 11 Mts Long RCC Poles /rail pole

23

4900

112700

... More
Removing of 11 KV ACSR Racoon Conductor

14

6250

87500

... More
Removing of 200amps GOAB Switch

18

1985

35739

... More
Removing of 11 kv Pin insulator with GI Pin

235

76

17860

... More
Removing of 11 kv Disc insulator with metal parts

255

187

47812.5

... More
Removing of V Shape Cross Arm Channel of 11kv line

82

169

13858

... More
Removing of Cut point channel of 11kv line

38

246

9348

... More
Removing of Top Fitting of 11kv Pin Insulators

53

114

6042

... More
Removing of old existing distibution box

13

2343

30465.5

... More
Removing of old exsiting HG fuse units

18

1684

30312

... More
Removing of old existing Lightening arrestors

51

87

4437

... More
Removing of old existing structure materials

5100

23

119850

... More
Removing of armoured cable cable 3.5 core x 240 sqmm

330

136

44880

... More
Removing of armoured cable cable 3.5 core x 150sqmm

330

111

36630

... More
Removing of armoured cable cable 3.5 core x 95 sqmm

330

74

24585

... More
Civil work

-

-

-

... More
Earthworkin excavation by mechanical means (Hydraulic excavator)/manual means over areas (exceeding 30cm in depth,1.5m in width as well as 10sq.m on plan) including disposal of excavated eath lead upto 50m and lift upto 1.5m disposed earth to be leveled and neatly dressed including providing barricading, danger lightting guarding as directed in : b) All types of ordinary rock including all types of laterite rock , blasting prohibited.

220.04

639

140605.56

... More
Refilling the pipeline/foundation trenches plinth sides, foundation etc. with available excavated earth in layers not exceeding 20 cm depth consolidating each layer ramming and watering lead upto 50 M and all lifts and disposal of surplus earth as directed by Engineer In Charge

130.44

245

31957.8

... More
Rubble packing with hard laterite stone under floors including watering ramming and consolidating etc.in pipeline trenches and other foundation complete.

44.04

2211

97372.44

... More
Providing & laying cement concrete 1:2:4 (1 cement : 2 coarse : 4graded granitic or basaltic stone aggrt.20mm.nominal size) excluding cost of centering, shuttering and finishing in : a) All works upto plinth level.

57.26

6810

389940.6

... More
Laterite masonry in neatly dressed stones of size as specified in cement mortar 1:4(1 cement: 4 coarse sand) in foundation and basement

95.04

5186

492877.44

... More
Centering and shuttering including struttings,propping etc. and removal of framework for : (i) Foundations , footings, bases for columns.

350.88

407

142808.16

... More
12mm cement plaster 1:4 (1 cement :4 fine sand)

783

223

174609



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements

Past Bidders
This list is curated from the bidders of the similar tenders in the past

Unlock the Tender details for free
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.