Electricity Department Tender

View complete overview of Goa Electricity Department Tender

Electricity Department Tender

Works
Electrical and Electronics
Eprocure
Opening Date14 Mar 2024
Closing Date9 Apr 2024
Tender Amount₹ 9,51,12,068 
Notes
Download

Costs

  • EMD

    ₹ 19,02,241
  • Document Cost

    ₹ 1,500
  • Tender Fee

    ₹ 6,000

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
Strain Insulator String hardware + clamp with installation

204

39412800

193200

... More
Armor Rod + cable tie pole alignment with installation

174

3427800

19700

... More
Vibration Damper

204

3060000

15000

... More
Mid span joints with Installation

5

925000

185000

... More
Repair sleeve with Installation

5

14689

2937.87

... More
Polymer/ Silicon Long Rod Insulator for Tension with Installation

204

612000

3000

... More
Polymer/ Silicon Long Rod Pin Insulator for single pole and double pole with Installation

288

864000

3000

... More
Post insulator with connector Suitable for ACCC Helsinki Conductor with Installation

114

456000

4000

... More
Substation Quantities

-

-

-

... More
T Clamp with hole for Incoming & Outgoing Feeder

30

188700

6290

... More
T Clamp without hole for Incoming & Outgoing Feeder

30

188700

6290

... More
33KV 'V' shaped X-arm made of 100 x 50 x 6 ISMC channel for Single Pole

87

211062

2426

... More
V' shape X-arm clamp for 90 lb/yd pole

87

44283

509

... More
Cutpoint Channel of 3 mts long made of 100 x 50 x 6mm ISMC for Double Pole Structure

164

443128

2702

... More
Cut point Channel Clamp for Single and Double Pole

279

100440

360

... More
Gl packing pieces for Rail Pole 90 lb

140

37240

266

... More
33KV Stay set Complete

102

607818

5959

... More
Stay clamps for Stay Set

102

69360

680

... More
11 mts Rail Pole 90 lb/yd for replacing damaged RCC pole/R.S. Joists

18

729000

40500

... More
GI Strip 25 X 5

75

8700

116

... More
GI Strip 50 X 6

200

41600

208

... More
Earthing complete with 40mm GI Pipe, 2.5 mts long alongwith Batonite complete with brick masonary.

34

267172

7858

... More
Nuts & Bolts

1000

228000

228

... More
33kV Current Transfomer (800-400/5-5A, 30-30VA,0.5-5P20) for Incoming Feeder, Bus Bar Strengtheing & Transformer Bay for 25 kA for 3 sec as per IS 2705.

12

726000

60500

... More
36kV Vaccum Circuit Breaker (1250 Amp) Incoming Feeder, & Transformer Bay for 25 kA for 3 sec as per IS 13118.

2

826250

413125

... More
30kV Lightning Arrestor for Incoming Feeder & Conversion from Overhead Line to Underground Cable for 10kA as per IS 3070 Part 3.

12

317436

26453

... More
36kV Potential Transformer for Incoming Feeder (33/V3/110/V3, 100 VA, 0.5 Cl) as per IS 3156.

12

726000

60500

... More
SETC of 36kV Isolator with Earth Switch (1250 Amp) for Incoming Feeder, Bus Bar Strengtheing & Transformer Bay for 25 kA for 3 sec as per IS 9920

6

1380000

230000

... More
Incoming Feeder Control & Relay (C&R) Panel for 36kV VCB as per IS 2147.

2

1700000

850000

... More
Incoming Feeder Bay Marshelling kiosk (64 Ways/128 Ways)

4

271920

67980

... More
Control Cable (0.400 kV, 12C X 2.5 SQ MM) from Equipment to BMK & to C&R Panel (Mtr.)

500

59500

119

... More
Control Cable (0.400 kV, 19C X 2.5 SQ MM) from Equipment to BMK & to C&R Panel (Mtr.)

1000

421000

421

... More
Control Cable (0.400 kV, 12C X 2.5 SQ MM) from Equipment to BMK & to C&R Panel (Mtr.)

500

234500

469

... More
Control Cable (0.400 kV, 19C X 2.5 SQ MM) from Equipment to BMK & to C&R Panel (Mtr.)

300

214200

714

... More
Gantry Steel Structure (Single Tier-3 Column & 2 Beam) in MT

5.18

875420

169000

... More
Gantry Steel Bar used for Foundation purpose in MT

1

169000

169000

... More
Supporting steel structure for LA, CT, PT, Circuit Breaker, Isolator Equipment

2

338000

169000

... More
Steel Bar used for Foundation for LA, CT, PT, Circuit Breaker, Isolator Equipment Foundation

1

169000

169000

... More
Current Transformer Connector(3Nos. Per Set)

8

94160

11770

... More
SF6 Circuit Breaker Connector(3Nos. Per Set)

8

102000

12750

... More
Lightning Arrestor Connector Pad(3Nos. Per Set)

4

51000

12750

... More
Potential Transformer Connector Pad(3Nos. Per Set)

8

102000

12750

... More
Isolator Connector Pad(3Nos. Per Set)

12

141240

11770

... More
SETC of Enamelled Danger board of size 250mm x 200 mm

60

14880

248

... More
SETC of Anti Climbing Device

60

57720

962

... More
SETC of ACSR Weasel for guarding

2

66818

33409

... More
SETC of HDGI 50 x 50 Angle for guardning with clamps and nut bolt

12

4452

371

... More
Cost Of Erection

-

-

-

... More
HTLS conductor Capable of for 450 Amps.

17.38

8776900

505000

... More
Transmission Line & Substation Components

-

-

-

... More
Strain Insulator String hardware + clamp with installation

204

2652000

13000

... More
Armor Rod + cable tie pole alignment with installation

174

348000

2000

... More
Vibration Damper

204

224400

1100

... More
Mid span joints with Installation

5

45000

9000

... More
Repair sleeve with Installation

5

1750

350

... More
Polymer/ Silicon Long Rod Insulator for Tension with Installation

204

153000

750

... More
Polymer/ Silicon Long Rod Pin Insulator for single pole and double pole with Installation

288

216000

750

... More
Post insulator with connector Suitable for ACCC Helsinki Conductor with Installation

114

342000

3000

... More
Substation Quantities

-

-

-

... More
T Clamp with hole for Incoming & Outgoing Feeder

30

30000

1000

... More
T Clamp without hole for Incoming & Outgoing Feeder

30

30000

1000

... More
33KV 'V' shaped X-arm made of 100 x 50 x 6 ISMC channel for Single Pole

87

37323

429

... More
V' shape X-arm clamp for 90 lb/yd pole

87

6003

69

... More
Cutpoint Channel of 3 mts long made of 100 x 50 x 6mm ISMC for Double Pole Structure

164

120048

732

... More
Cut point Channel Clamp for Single and Double Pole

279

13113

47

... More
Gl packing pieces for Rail Pole 90 lb

140

7420

53

... More
33KV Stay set Complete

102

220728

2164

... More
Stay clamps for Stay Set

102

10506

103

... More
11 mts Rail Pole 90 lb/yd for replacing damaged RCC pole/R.S. Joists

18

378900

21050

... More
GI Strip 25 X 5

75

3600

48

... More
GI Strip 50 X 6

200

9600

48

... More
Earthing complete with 40mm GI Pipe, 2.5 mts long alongwith Batonite complete with brick masonary.

34

166838

4907

... More
Nuts & Bolts

1000

30000

30

... More
For New Pole : -

-

-

-

... More
Earthwork in excavation by mechanical means (hydraulic excavator)/manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sq.m on plan) including disposal of excavated earth lead upto 50 m and lift upto 1.5m disposed earth to be leveled and neatly dressed including providing barricading, danger lighting guarding as directed for all types of soils for

-

-

-

... More
11Mtr poles

41.7

31817

763

... More
11Mtr poles with Muffing

28.85

160261

5555

... More
For Old Pole : -

-

-

-

... More
Earthwork in excavation by mechanical means (hydraulic excavator)/manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sq.m on plan) including disposal of excavated earth lead upto 50 m and lift upto 1.5m disposed earth to be leveled and neatly dressed including providing barricading, danger lighting guarding as directed for all types of soils for

-

-

-

... More
Rail/RCC/RS Joist poles

15

11445

763

... More
Rail/RCC/RS Joist poles

5

27775

5555

... More
Muffing : -

-

-

-

... More
Rail/RCC/RS Joist poles

40

222200

5555

... More
Removing of 33KV 'V' shape X-arm & handling in stores

87

18661

214.5

... More
Removing of 33KV Pin insulators

261

20358

78

... More
Removing of G.I. of 33KV Pin Insulators

204

15504

76

... More
Removing of Disc Insulators

636

62010

97.5

... More
Removing of ACSR Raccoon Conductor

18

93006

5167

... More
33kV Current Transfomer (800-400/5-5A, 30-30VA,0.5-5P20) for Incoming Feeder, Bus Bar Strengtheing & Transformer Bay for 25 kA for 3 sec as per IS 2705.

12

79200

6600

... More
36kV Vaccum Circuit Breaker (1250 Amp) Incoming Feeder, & Transformer Bay for 25 kA for 3 sec as per IS 13118.

2

33800

16900

... More
30kV Lightning Arrestor for Incoming Feeder & Conversion from Overhead Line to Underground Cable for 10kA as per IS 3070 Part 3.

12

10584

882

... More
36kV Potential Transformer for Incoming Feeder (33/V3/110/V3, 100 VA, 0.5 Cl) as per IS 3156.

12

79200

6600

... More
SETC of 36kV Isolator with Earth Switch (1250 Amp) for Incoming Feeder, Bus Bar Strengtheing & Transformer Bay for 25 kA for 3 sec as per IS 9920

6

79758

13293

... More
Incoming Feeder Control & Relay (C&R) Panel for 36kV VCB as per IS 2147.

2

37000

18500

... More
Incoming Feeder Bay Marshelling kiosk (64 Ways/128 Ways)

4

110000

27500

... More
Control Cable (0.400 kV, 12C X 2.5 SQ MM) from Equipment to BMK & to C&R Panel (Mtr.)

500

21000

42

... More
Control Cable (0.400 kV, 19C X 2.5 SQ MM) from Equipment to BMK & to C&R Panel (Mtr.)

1000

74000

74

... More
Control Cable (0.400 kV, 12C X 2.5 SQ MM) from Equipment to BMK & to C&R Panel (Mtr.)

500

37000

74

... More
Control Cable (0.400 kV, 19C X 2.5 SQ MM) from Equipment to BMK & to C&R Panel (Mtr.)

300

24900

83

... More
Gantry Steel Structure (Single Tier-3 Column & 2 Beam) in MT

5.18

243460

47000

... More
Gantry Steel Bar used for Foundation purpose in MT

1

47000

47000

... More
Supporting steel structure for LA, CT, PT, Circuit Breaker, Isolator Equipment

2

94000

47000

... More
Steel Bar used for Foundation for LA, CT, PT, Circuit Breaker, Isolator Equipment Foundation

1

47000

47000

... More
Foundation volume (cu.m) (M20 Grade) for Gantry, LA, CT, PT, Circuit Breaker, Isolator Equipment

80

444400

5555

... More
Foundation volume (cu.m) (M10 Grade) for Gantry, LA, CT, PT, Circuit Breaker, Isolator Equipment

10

55550

5555

... More
Excavation volume (cu.m) Gantry, LA, CT, PT, Circuit Breaker, Isolator Equipment

250

190750

763

... More
Current Transformer Connector(3Nos. Per Set)

8

34176

4272

... More
SF6 Circuit Breaker Connector(3Nos. Per Set)

8

148720

18590

... More
Lightning Arrestor Connector Pad(3Nos. Per Set)

4

4680

1170

... More
Potential Transformer Connector Pad(3Nos. Per Set)

8

34176

4272

... More
Isolator Connector Pad(3Nos. Per Set)

12

93480

7790

... More
Dismentaling of Gantry Steel Structure (Single Tier-3 Column & 2 Beam) in MT

5

117500

23500

... More
Dismentaling of existing 33KV CT

12

39600

3300

... More
Dismentaling of existing 33KV PT

12

39600

3300

... More
Dismentaling of existing 33KV LA

12

8904

742

... More
Dismentaling of existing 33KV Isolator

6

32796

5466

... More
SETC of Enamelled Danger board of size 250mm x 200 mm

60

3420

57

... More
SETC of Anti Climbing Device

60

10500

175

... More
SETC of ACSR Weasel for guarding

2

14220

7110

... More
SETC of HDGI 50 x 50 Angle for guardning with clamps and nut bolt

12

1584

132

... More
Removing of Existing 11Mtr Rail Pole

6

63150

10525

... More
Labour for tree cutting along the route for line clearance

1.75

203644

116368



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.