Electricity Department Tender
View complete overview of Goa Electricity Department Tender
Costs
EMD
₹ 8,01,149Document Cost
₹ 1,500Tender Fee
₹ 6,000
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2024_ED_14963_1Bid Award Id
ViewTender No
Tender-91/Div-V (2023-24)Tender Authority
Electricity Department ViewPurchaser Address
-Website
http://eprocure.goa.gov.in
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
BOQ Items
... More
Supply of Underground Cable protective cover as per specification as given below: The concrete slab should be machine made using semi-dry concrete that is batched in a fully automatic PLC controlled concrete batching plant and cast in a fully automatic "Vibro-Press" machine with a high vibration frequency and a hydraulic pressure of 40 MT. The size of the slab shall be 480mm x 250mm x 50mm (+- 2mm) and the concrete grade shall be M30 adhering to IS 456 : 2000 and shall have a minimum crushing strength of 30N/mm2 (28 days strength) when tested. Calculation: (6800/0.48)
14167
1912545
135
... More
Supplying in plinth under floors, trenches including watering ramming consolidating, dressing, complete. Sand (0.2*0.4*6800m)- Cable (0.03cubics*6800)
340
737800
2170
... More
RCC Cable route marker (400 x 900 x 100mm) (as per CEE approved drawing, copy enclosed) (one per every 100m for entire route length)
69
36432
528
... More
Supply of Warning tape.
6.96
104400
15000
... More
LATERITE MASONARY WORKS: RUBBLE PACKING WITH HARD LATERITE STONE UNDER FLOORS INCLUDING WATERING RAMMING AND CONSOLIDATING ETC. IN PIPELINE TRENCHES AND OTHER FOUNDATION COMPLETE FOR: a)Single Circuit 33kV Cable Trench (0.2*0.7*6800)
952
2104872
2211
... More
Laying of 33kV/LT UG cable size 300 sq.mm. and 400 sq.mm. by trenchless technology by adopting horizontal directional drilling (HDD Method). The work includes preparation of site, Boring as well as drawing of cable in Hard/Laterite Stone with minimum 9'' bore size, including supply and erection of HDPE Pipe 160mm PN6 PE80 Wall Thickness 9.5mm (minimum) as per IS 4984:1995 amendment 2016. The depth shall be 1.650m to 1.850m (1650mm-1850mm) only except at entry and exit pits where minimum depth shall be 1200mm
60
-
-
... More
Supply of 3 Core XLPE armoured cable 33KV 400 sq.mm Aluminium Armoured Cable (by open trench method)
6840
24624000
3600
... More
Supply of 3 Core XLPE armoured cable 33KV 400 sq.mm Aluminium Armoured Cable (by HDD method)
60
216000
3600
... More
H.S. 33kV Indoor Termination Kit 3C 400sq.mm. XLPE
2
44656
22328
... More
H.S. 33kV Outdoor Termination Kit 3C 400sq.mm. XLPE
4
129280
32320
... More
H.S. 33kV Straight Through Joint 3C 400sq.mm. XLPE (Considering length of the cable for one cable drum as 500m)
13
744250
57250
... More
3-Way RMU - Ring Main Unit : 33kV, 630A, 25KA, 3-Way Outdoor Load Break Switch comprising of 3Nos. 630A Isolators (3 LBS)
1
2478000
2478000
... More
Earthing complete with 40mm GI Pipe, 2.5 mts long alongwith 20 kgs each salt, charcoal complete with brick masonary. (2*47 RMU)
3
13284
4428
... More
GI pipe 150mm, class B (as raiser) (6m*4 Cable Raisers)
24
40344
1681
... More
Civil Work for erection of 33kV UG cable for 33kV Valpoi-1 feeder (Civil work for RMU)
1
38471
38471.65
... More
Erection of Material
-
-
-
... More
Earthwork in excavation by mechanical means (hydraulic excavator)/manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sq.m on plan) including disposal of excavated earth lead upto 50 m and lift upto 1.5m disposed earth to be leveled and neatly dressed including providing barricading, danger lighting guarding as directed in : b) All types of Ordinary rock including all types of laterite rock, blasting prohibited (1.3*0.4*6800m)
3536
2697968
763
... More
Refilling the pipeline/foundation trenches plinth sides, foundation etc. with available excavated earth in layers not exceeding 20 cm depth consolidating each layer ramming and watering lead upto 50 M and all lifts and disposal of surplus earth as directed by Engineer in Charge. Deduct for RCC Slab (1.1*0.4*6800m) - (0.48*0.25*0.05*No. of Prot. covers 14167 )
2907
348840
120
... More
Laying of Underground Cable protective cover as per specification as given below: The concrete slab should be machine made using semi-dry concrete that is batched in a fully automatic PLC controlled concrete batching plant and cast in a fully automatic "Vibro-Press" machine with a high vibration frequency and a hydraulic pressure of 40 MT. The size of the slab shall be 480mm x 250mm x 50mm (+- 2mm) and the concrete grade shall be M30 adhering to IS 456 : 2000 and shall have a minimum crushing strength of 30N/mm2 (28 days strength) when tested. Calculation: (6800/0.48)
14167
850020
60
... More
filling in plinth under floors, trenches including watering ramming consolidating, dressing, complete. Sand (0.2*0.4*6800m)- Cable (0.03cubics*6800)
340
-
-
... More
RCC Cable route marker (400 x 900 x 100mm) (as per CEE approved drawing, copy enclosed) (one per every 100m for entire route length)
69
17664
256
... More
Erection of Warning tape.
7
-
-
... More
LATERITE MASONARY WORKS: RUBBLE PACKING WITH HARD LATERITE STONE UNDER FLOORS INCLUDING WATERING RAMMING AND CONSOLIDATING ETC. IN PIPELINE TRENCHES AND OTHER FOUNDATION COMPLETE FOR: a)Single Circuit 33kV Cable Trench (0.2*0.7*6800)
952
-
-
... More
Laying of 33kV/LT UG cable size 300 sq.mm. and 400 sq.mm. by trenchless technology by adopting horizontal directional drilling (HDD Method). The work includes preparation of site, Boring as well as drawing of cable in Hard/Laterite Stone with minimum 9'' bore size, including supply and erection of HDPE Pipe 160mm PN6 PE80 Wall Thickness 9.5mm (minimum) as per IS 4984:1995 amendment 2016. The depth shall be 1.650m to 1.850m (1650mm-1850mm) only except at entry and exit pits where minimum depth shall be 1200mm
60
257760
4296
... More
Laying of 3 Core XLPE armoured cable 33KV 400 sq.mm Aluminium Armoured Cable (by open trench method)
6840
2537640
371
... More
Laying of 3 Core XLPE armoured cable 33KV 400 sq.mm Aluminium Armoured Cable (by HDD method)
60
-
-
... More
H.S. 33kV Indoor Termination Kit 3C 400sq.mm. XLPE
2
8282
4141
... More
H.S. 33kV Outdoor Termination Kit 3C 400sq.mm. XLPE
4
17564
4391
... More
H.S. 33kV Straight Through Joint 3C 400sq.mm. XLPE (Considering length of the cable for one cable drum as 500m)
13
71500
5500
... More
3-Way RMU - Ring Main Unit : 33kV, 630A, 25KA, 3-Way Outdoor Load Break Switch comprising of 3Nos. 630A Isolators (3 LBS)
1
13500
13500
... More
Earthing complete with 40mm GI Pipe, 2.5 mts long alongwith 20 kgs each salt, charcoal complete with brick masonary. (2*47 RMU)
3
7995
2665
... More
GI pipe 150mm, class B (as raiser) (6m*4 Cable Raisers)
24
4368
182
... More
Civil Work for erection of 33kV UG cable for 33kV Valpoi-1 feeder (Civil work for RMU)
1
-
-
Evaluation Notes How It Works ?
Potential Partner