Electricity Department Tender

View complete overview of Goa Electricity Department Tender

Electricity Department Tender

Works
Civil And Construction
Civil Works Others
Eprocure
Opening Date24 Jan 2024
Closing Date29 Feb 2024
Tender Amount₹ 22,49,213 
Notes
Download

Costs

  • EMD

    ₹ 44,984
  • Document Cost

    ₹ 1,500
  • Tender Fee

    ₹ 4,498

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
Supply of Cross Arm Channel 4Pin .The cross arms shall be made of M.S. channel of ISMC-75 vide table 2 of IS: 8081 1964 . The cross arms shall be without any joints. The cross arms shall be hot dipped galvanized generally conforming to IS - 2633/72. The length of the 4pin cross arm shall be 1110mm with 4 holes of 22 dia each on each flange section. In addition 2 holes of size 18mm x 40mm slotted holes shall be provided on the cross arm for clamping arrangement to the pole. The length of the 4pin side cross arm shall be 1410mm with 4 holes of 22 dia each on each flange section. In addition 2 holes of size 18mm x 40mm slotted holes shall be provided on the cross arm 40 mm from the left edge of the X-arm for clamping arrangement to the pole & two holes of size 17mm dia at 355mm & 660mm from the slotted hole for arrangement to fix angle support. The angle support shall be of ISA 50x50x6mm G.I. with 17 mm dia holes at the two ends. The other end of the angle shall be clamps utilizing suitable G. I. stay clamps of length 312mm end to end

19

21071

1109

... More
Supply of Cross Arm Channel 2Pin .The cross arms shall be made of M.S. channel of ISMC-75 vide table 2 of IS: 8081 1964 . The cross arms shall be without any joints. The cross arms shall be hot dipped galvanized generally conforming to IS - 2633/72. The length of the 4pin cross arm shall be 1110mm with 4 holes of 22 dia each on each flange section. In addition 2 holes of size 18mm x 40mm slotted holes shall be provided on the cross arm for clamping arrangement to the pole. The length of the 4pin side cross arm shall be 1410mm with 4 holes of 22 dia each on each flange section. In addition 2 holes of size 18mm x 40mm slotted holes shall be provided on the cross arm 40 mm from the left edge of the X-arm for clamping arrangement to the pole & two holes of size 17mm dia at 355mm & 660mm from the slotted hole for arrangement to fix angle support. The angle support shall be of ISA 50x50x6mm G.I. with 17 mm dia holes at the two ends. The other end of the angle shall be clamps utilizing suitable G. I. stay clamps of length 312mm end to end

19

10811

569

... More
Supply of GI Xarm clamp LA for 11mts pole.shall be hot dipped galvanized generally conforming to IS - 2633/73

10

4140

414

... More
Supply of GI stay clamp SA for 11mts pole.shall be hot dipped galvanized generally conforming to IS - 2633/73

4

1656

414

... More
Supply of GI Xarm clamp LA for 9mts pole.shall be hot dipped galvanized generally conforming to IS - 2633/74

22

5852

266

... More
Supply of GI Xarm clamp SA for 9mts pole.shall be hot dipped galvanized generally conforming to IS - 2633/75

2

532

266

... More
Supply of GI stay clamp SA for 11mts pole.shall be hot dipped galvanized generally conforming to IS - 2633/73

2

1242

621

... More
Supply of GI stay clamp LA for 11mts pole.shall be hot dipped galvanized generally conforming to IS - 2633/73

3

1863

621

... More
Supply of GI stay clamp LA for 9.0mts pole.shall be hot dipped galvanized generally conforming to IS - 2633/73

3

1473

491

... More
Supply of 11 KV V shape cross arm.Cross arms shall be made of HDGI channel of size ISMC 75X40X7.3mm. hot dip galvanizing generally conforming to IS – 2633/72 . The cross arm shall not be welded/joined at any place except as specified

2

2938

1469

... More
Supply of 11 KV Disc Insulators 45KN with H.D.G.I. Metal parts.11 KV disc insulators ball and socket type, type ‘A’ porcelain brown glazed duly cemented at factory with MCI socket cap, forged steel ball pin and supplied with Phosphor bronze “W” split pin as per IS 731-1971 as amended upto date. Pin ball diameter 16 mm. Minimum Creepage distance 320 mm. Ferrous parts shall be galvanized as per relevant IS

6

14190

2365

... More
Supply of 11 KV Pin Insulator with H.D.G.I. Pin 11 KV brown glazed porcelain pin insulator with minimum failing load of 5 KN and the Minimum creepage distance of 320 mm conforming to IS 731-1971 as amended upto date.Insulators shall be marked and packed as per IS

3

2079

693

... More
Supply of Guard cross arm 1.5 mtr long.Cross arms shall be made of HDGI channel of size ISMC 75X40. hot dip galvanizing generally conforming to IS – 2633/72 . The cross arm shall not be welded/joined at any place except as specified

1

2196

2196

... More
Supply of ACSR 'WEASEL' of size ( 6/1/2.59mm) for earthing and jumpering .Packing and marking of drum will be as per IS:Conductor length shall be 1500 mtr. with tolerance of +/- 5%

0.1

3340

33409

... More
Supply of Insulator -(LT) Shackle .L.T. brown glazed shackle insulators of size 100mm x 115mm conforming to fig.No.4 and type 2 of IS: 1445/77 as amended upto date. Minimum failing load shall be 16kN. Insulators shall have marking and packing as prescribed in IS

66

24552

372

... More
Supply of conductor-AA ANT, 2. 7/3.10 mm .

1.94

93479

48086

... More
Supply of conductor -AA GNAT,1. 7/2.21 mm,

2.09

52963

25293

... More
Supply of HDGI nuts & bolts.G.I. Hexagonal head bolts and hexagonal nuts conforming to IS 1363 part 1 to 3 1992 as amended upto date.The bolts and nuts shall be hot dip galvanized as per IS: 2629-1985 as amended upto date

30

6840

228

... More
Supply of HDGI Streetlight Clamps for 40 mm pipe(Top/bottom)

16

8032

502

... More
Supply of LT pin insulator with GI pin

66

17358

263

... More
Supply of Stay set complete for 9.0 mts RCC Pole.HDGI Stay Sets Complete Comprising of stay rod with plate, HDGI stay wire of size 7/10swg, Break insulator of 15KV/8KV,HDGI turn buckle with eye bolt, suitable HDGI stay clamps, HDGI nut bolts, . The Stay wire shall comply with the specific requirements of IS: 2141-1979, IS: 4826-1979 & IS: 6594-1974 or the latest versions thereof and also as per the specifications enclosed.

7

30569

4367

... More
Supply of Stay set complete for 11 mts RCC Pole.HDGI Stay Sets Complete Comprising of stay rod with plate, HDGI stay wire of size 7/10swg, Break insulator of 15KV/8KV,HDGI turn buckle with eye bolt, suitable HDGI stay clamps, HDGI nut bolts, . The Stay wire shall comply with the specific requirements of IS: 2141-1979, IS: 4826-1979 & IS: 6594-1974 or the latest versions thereof and also as per the specifications enclosed.

4

18456

4614

... More
Supply of RCC Hume Pipe 150mm dia with required no. of collars, for road crossing.

60

24420

407

... More
Supply of 11KV, 3 core, 300 sq.mm. aluminium, XLPE insulated, flat armoured, 11 KV (Earthed) Cable, type A2XFY of approved make conforming I.S. 7098 PART 2 and with ISI MARK through open trench method in any type of soil including hard laterite.

61

142618

2338

... More
Supply of 11KV, 3 core 150 sq.mm aluminium, XLPE insulated, flat armoured, 11 KV (Earthed) Cable, type A2XFY of approved make conforming I.S. 7098 PART 2 and carrying ISI MARK through conventional open trenching method in any type of soil including hard laterite.

17

24769

1457

... More
S.upply of straight through joint complete for 11 KV XLPE cable of size 3 x 300sq.mm including sockets/lugs/connectors etc. of approved make.

3

88677

29559

... More
Supply of 11KV, 3 phase, Indoor type, heat shrinkable end termination kit complete, for 11 KV XLPE cable of size 3 x 300sq.mm including sockets/lugs/connectors etc. for connecting RMU for main section side of approved make .

5

44200

8840

... More
Supply of 11KV 3 phase indoor terminating kit complete, for 11 KV XLPE cable of size 3 x 150sq.mm including sockets/lugs/connectors etc. for connecting RMU for main section side of approved make.

1

7873

7873

... More
Supply of 11KV 3 phase outdoor terminating kit complete, for 11 KV XLPE cable of size 3 x 150sq.mm including sockets/lugs/connectors etc. for connecting RMU for main section side of approved make.

1

10931

10931

... More
supplyof 3½ core 240 sq.mm. aluminium, XLPE insulated armoured 1.1KV power cable and carrying ISI MARK & of approved make. The work includes termination with Aluminum lugs & providing glands at respective equipment.

182

309036

1698

... More
Supply of 1 core, 300sq.mm, Al conductor XLPE insulated 1.1KV grade unarmoured power cable and carrying ISI MARK & approved make.The work includes termination with Aluminum lugs & providing glands at LVSB. (from transformer to LV distribution board)

64

30528

477

... More
Supply of 3½ core 95 sq.mm. aluminium, XLPE insulated armoured 1.1KV power cable and carrying ISI MARK & of approved make with accessories.The work includes termination with Aluminum lugs & providing glands at Respective equipment.

34

24956

734

... More
Supply of Alluminium XLPE Armoured cable 4C x 16 sq.mm, 1.1KV Grade including termination of cable with lugs . The cable shall carry concerned ISI mark & approved make. The work includes termination with Aluminum lugs & providing glands at respective equipment.

67

13333

199

... More
415 V straight through joint 3.5 C X 300 Sq.mm

2

4408

2204

... More
415 V straight through joint 3.5 C X 95Sq.mm

5

9665

1933

... More
Supply of FRP Fencing complete with Gate around every distribution sub-station containing RMU, one distribution transformer and one LV switchboard including danger plate (Size  4Mx3Mx2M) with Concreting for FRP Fencing supports with plinth (0.3x0.3x0.5) Cu.m. x 12 nos. Each ratio 1:3:6

1

76667

76667

... More
Supply of Enamelled danger board of size 250mm x 200mm

4

992

248

... More
Supply of Cable route Markers (for entire HT/LT cable route length ) as per NIT drawing.

8

4224

528

... More
Supply of warning tape

0.13

1875

15000

... More
Supply of fine river sand of approved quality for cushioning of HT/ LT underground cables laid by conventional Open Trenching Method.

4.56

9895

2170

... More
Supply of cable protective cover as per specification as given below: The concrete slab shall be machine made using semi dry concrete batching plant and cast in a fully automatic PLC controlled concrete batching plant and cast in a fully automatic " Vibro - Press" machine with a high vibration frequency and hydraulic pressure of 40 MT, the size of the slab shall be 480 X 250mm x 50mm, (+/- 2mm) and the concrete grade shall be M30 adhering to IS 456:2000 and shall have a minimum crushing strenght of 30N/mm2( 28 days strength) when tested.

173

23355

135

... More
Supply of Wire cut bricks for 11KV cable seperation

80

760

9.5

... More
Laterite Masonary Works Rubble packing with hard laterite stone under floors including watering ramming and consolidating etc, in pipeline trenches and other foundations complete for: Single circuit 11 kV cable trench and Double circuit 11 kV cable trench and LT cable trench

18

39798

2211

... More
Supply. of G.I. earthing pipe, 2500mm long, 40mm nominal dia, class B, perforated for RMU's, Transformers, LVSB's, Feeder Pillar's, Service Pillar's , Streetlight Pillar's, Streetlight Poles . The pit shall be filled with homogenous mixture of 20Kgs of Charcoal, 20Kgs of salt and sand /soil with Brick masonary Chambers The work includes excavation, backfilling & spreading of excavated surplace earth evenly at RMU's, LV Switchboard etc.

15

40950

2730

... More
Supply of HDGI flat of size 25mm x 5mm for earthing of RMU's, Transformers, LVSB's, Feeder Pillar's, Service Pillar's , Streetlight Pillar's, Streetlight Poles

75

8700

116

... More
Providing and laying in position cement concrete 1:2:4 (1 cement : 2 coarse sand: 4 graded granitic or basaltic stone aggregate 40 m nominal size for foundations of RMU's, Transformers, LVSB's, Feeder Pillar's, Service Pillar's , Streetlight Pillar's, cement concrete for laying foundation for octagonal poles including the cost of centering, shuttering and muffing 0.5 m above ground and of diameter 0.5 m (Pit dimensions : 0.5 X 0.5 X 1.2 mts.)

6.48

35996

5555

... More
Providing of Centering and shuttering including struttings, propping etc. and removal of formwork for a) Foundations, footings, bases of columns and mass concrete for Feeder Pillar's, Service Pillar's , Streetlight Pillar's, Streetlight Poles

22.95

12920

563

... More
Providing of Masonary work for Transformer's plinth using hard laterite stones

1.35

10011

7416

... More
Providing of 12 mm cement plaster 1:4 ( 1 cement: 4 fine sand) for foundations of Feeder Pillar's, Service Pillar's , Streetlight Pillar's

13.52

1986

147

... More
Supply of GI Pipe 150mm, class B for for cable rising on DTC & RCC pole

10

16810

1681

... More
Erection Cost

-

-

-

... More
Erection of 9 mts. long RCC poles .The poles should be as per drawing approved by CEE and conforming to IS standards as amended upto date. The Component used for pole shall conform to following IS amended upto date.

14

61712

4408

... More
Erection of 11mts. long RCC poles .The poles should be as per drawing approved by CEE and conforming to IS standards as amended upto date. The Component used for pole shall conform to following IS amended upto date.

6

51600

8600

... More
Fixing of Cross Arm Channel 4Pin .The cross arms shall be made of M.S. channel of ISMC-75 vide table 2 of IS: 8081 1964 . The cross arms shall be without any joints. The cross arms shall be hot dipped galvanized generally conforming to IS - 2633/72. The length of the 4pin cross arm shall be 1110mm with 4 holes of 22 dia each on each flange section. In addition 2 holes of size 18mm x 40mm slotted holes shall be provided on the cross arm for clamping arrangement to the pole. The length of the 4pin side cross arm shall be 1410mm with 4 holes of 22 dia each on each flange section. In addition 2 holes of size 18mm x 40mm slotted holes shall be provided on the cross arm 40 mm from the left edge of the X-arm for clamping arrangement to the pole & two holes of size 17mm dia at 355mm & 660mm from the slotted hole for arrangement to fix angle support. The angle support shall be of ISA 50x50x6mm G.I. with 17 mm dia holes at the two ends. The other end of the angle shall be clamps utilizing suitable G. I. stay clamps of length 312mm end to end

19

4959

261

... More
Fixing of Cross Arm Channel 2Pin .The cross arms shall be made of M.S. channel of ISMC-75 vide table 2 of IS: 8081 1964 . The cross arms shall be without any joints. The cross arms shall be hot dipped galvanized generally conforming to IS - 2633/72. The length of the 4pin cross arm shall be 1110mm with 4 holes of 22 dia each on each flange section. In addition 2 holes of size 18mm x 40mm slotted holes shall be provided on the cross arm for clamping arrangement to the pole. The length of the 4pin side cross arm shall be 1410mm with 4 holes of 22 dia each on each flange section. In addition 2 holes of size 18mm x 40mm slotted holes shall be provided on the cross arm 40 mm from the left edge of the X-arm for clamping arrangement to the pole & two holes of size 17mm dia at 355mm & 660mm from the slotted hole for arrangement to fix angle support. The angle support shall be of ISA 50x50x6mm G.I. with 17 mm dia holes at the two ends. The other end of the angle shall be clamps utilizing suitable G. I. stay clamps of length 312mm end to end

19

4408

232

... More
Fixing of GI Xarm clamp LA for 11mts pole.shall be hot dipped galvanized generally conforming to IS - 2633/73

10

650

65

... More
Fixing of GI stay clamp SA for 11mts pole.shall be hot dipped galvanized generally conforming to IS - 2633/73

4

260

65

... More
Fixing of GI Xarm clamp LA for 9mts pole.shall be hot dipped galvanized generally conforming to IS - 2633/74

22

990

45

... More
Fixing of GI Xarm clamp SA for 9mts pole.shall be hot dipped galvanized generally conforming to IS - 2633/75

2

90

45

... More
Fixing of GI stay clamp SA for 11mts pole.shall be hot dipped galvanized generally conforming to IS - 2633/73

2

196

98

... More
Fixng of GI stay clamp LA for 11mts pole.shall be hot dipped galvanized generally conforming to IS - 2633/73

3

294

98

... More
Fixing of GI stay clamp LA for 9.0mts pole.shall be hot dipped galvanized generally conforming to IS - 2633/73

3

237

79

... More
Fixing of 11 KV V shape cross arm.Cross arms shall be made of HDGI channel of size ISMC 75X40X7.3mm. hot dip galvanizing generally conforming to IS – 2633/72 . The cross arm shall not be welded/joined at any place except as specified

2

676

338

... More
Fixing of 11 KV Disc Insulators 45KN with H.D.G.I. Metal parts.11 KV disc insulators ball and socket type, type ‘A’ porcelain brown glazed duly cemented at factory with MCI socket cap, forged steel ball pin and supplied with Phosphor bronze “W” split pin as per IS 731-1971 as amended upto date. Pin ball diameter 16 mm. Minimum Creepage distance 320 mm. Ferrous parts shall be galvanized as per relevant IS

6

1992

332

... More
Fixing of 11 KV Pin Insulator with H.D.G.I. Pin 11 KV brown glazed porcelain pin insulator with minimum failing load of 5 KN and the Minimum creepage distance of 320 mm conforming to IS 731-1971 as amended upto date.Insulators shall be marked and packed as per IS

3

456

152

... More
Fixing of Guard cross arm 1.5 mtr long.Cross arms shall be made of HDGI channel of size ISMC 75X40. hot dip galvanizing generally conforming to IS – 2633/72 . The cross arm shall not be welded/joined at any place except as specified

1

546

546

... More
Stringing of ACSR 'WEASEL' of size ( 6/1/2.59mm) for earthing and jumpering .Packing and marking of drum will be as per IS:Conductor length shall be 1500 mtr. with tolerance of +/- 5%

0.1

711

7110

... More
Fixing of Insulator -(LT) Shackle .L.T. brown glazed shackle insulators of size 100mm x 115mm conforming to fig.No.4 and type 2 of IS: 1445/77 as amended upto date. Minimum failing load shall be 16kN. Insulators shall have marking and packing as prescribed in IS

66

13728

208

... More
Stringing of conductor-AA ANT, 2. 7/3.10 mm .

1.94

12896

6634

... More
Stringing of conductor -AA GNAT,1. 7/2.21 mm,

2.09

12947

6183

... More
Providing of HDGI nuts & bolts.G.I. Hexagonal head bolts and hexagonal nuts conforming to IS 1363 part 1 to 3 1992 as amended upto date.The bolts and nuts shall be hot dip galvanized as per IS: 2629-1985 as amended upto date

30

900

30

... More
Fixing of HDGI Streetlight Clamps for 40 mm pipe(Top/bottom)

16

752

47

... More
Fixing of LT pin insulator with GI pin

66

11418

173

... More
Providing of Stay set complete for 9.0 mts RCC Pole.HDGI Stay Sets Complete Comprising of stay rod with plate, HDGI stay wire of size 7/10swg, Break insulator of 15KV/8KV,HDGI turn buckle with eye bolt, suitable HDGI stay clamps, HDGI nut bolts, . The Stay wire shall comply with the specific requirements of IS: 2141-1979, IS: 4826-1979 & IS: 6594-1974 or the latest versions thereof and also as per the specifications enclosed.

7

17262

2466

... More
Proviidng of Stay set complete for 11 mts RCC Pole.HDGI Stay Sets Complete Comprising of stay rod with plate, HDGI stay wire of size 7/10swg, Break insulator of 15KV/8KV,HDGI turn buckle with eye bolt, suitable HDGI stay clamps, HDGI nut bolts, . The Stay wire shall comply with the specific requirements of IS: 2141-1979, IS: 4826-1979 & IS: 6594-1974 or the latest versions thereof and also as per the specifications enclosed.

4

10144

2536

... More
Laying of RCC Hume Pipe 150mm dia with required no. of collars, for road crossing.

60

9060

151

... More
SETC of 11KV, 3 core, 300 sq.mm. aluminium, XLPE insulated, flat armoured, 11 KV (Earthed) Cable, type A2XFY of approved make conforming I.S. 7098 PART 2 and with ISI MARK through open trench method in any type of soil including hard laterite.

61

20862

342

... More
SETC of 11KV, 3 core 150 sq.mm aluminium, XLPE insulated, flat armoured, 11 KV (Earthed) Cable, type A2XFY of approved make conforming I.S. 7098 PART 2 and carrying ISI MARK through conventional open trenching method in any type of soil including hard laterite.

17

4216

248

... More
S.E.T.C. of straight through joint complete for 11 KV XLPE cable of size 3 x 300sq.mm including sockets/lugs/connectors etc. of approved make.

3

11139

3713

... More
S.E.T.C. of 11KV, 3 phase, Indoor type, heat shrinkable end termination kit complete, for 11 KV XLPE cable of size 3 x 300sq.mm including sockets/lugs/connectors etc. for connecting RMU for main section side of approved make .

5

12740

2548

... More
S.E.T.C. of 11KV 3 phase indoor terminating kit complete, for 11 KV XLPE cable of size 3 x 150sq.mm including sockets/lugs/connectors etc. for connecting RMU for main section side of approved make.

1

2648

2648

... More
S.E.T.C. of 11KV 3 phase outdoor terminating kit complete, for 11 KV XLPE cable of size 3 x 150sq.mm including sockets/lugs/connectors etc. for connecting RMU for main section side of approved make.

1

2648

2648

... More
supply, laying, testing & commisioning of 3½ core 240 sq.mm. aluminium, XLPE insulated armoured 1.1KV power cable and carrying ISI MARK & of approved make. The work includes termination with Aluminum lugs & providing glands at respective equipment.

182

49504

272

... More
Supply, laying, testing & commisioning of 1 core, 300sq.mm, Al conductor XLPE insulated 1.1KV grade unarmoured power cable and carrying ISI MARK & approved make.The work includes termination with Aluminum lugs & providing glands at LVSB. (from transformer to LV distribution board)

64

13952

218

... More
Supply, laying, testing & commisioning of 3½ core 95 sq.mm. aluminium, XLPE insulated armoured 1.1KV power cable and carrying ISI MARK & of approved make with accessories.The work includes termination with Aluminum lugs & providing glands at Respective equipment.

34

5066

149

... More
Supply,laying, testing & commissioning of Alluminium XLPE Armoured cable 4C x 16 sq.mm, 1.1KV Grade including termination of cable with lugs . The cable shall carry concerned ISI mark & approved make. The work includes termination with Aluminum lugs & providing glands at respective equipment.

67

5360

80

... More
415 V straight through joint 3.5 C X 300 Sq.mm

2

4628

2314

... More
415 V straight through joint 3.5 C X 95Sq.mm

5

10905

2181

... More
Providing of FRP Fencing complete with Gate around every distribution sub-station containing RMU, one distribution transformer and one LV switchboard including danger plate (Size  4Mx3Mx2M) with Concreting for FRP Fencing supports with plinth (0.3x0.3x0.5) Cu.m. x 12 nos. Each ratio 1:3:6

1

25000

25000

... More
Fixing of Enamelled danger board of size 250mm x 200mm

4

228

57

... More
Providing of Cable route Markers (for entire HT/LT cable route length ) as per NIT drawing.

8

2048

256

... More
Excavation in any type of soil including hard laterite soil by mechanical means( hydraulic excavator)/manual means for laying of HT/LT cables of various sizes including excavation for equipment foundations i.e for including excavation for equipment foundations i.e for RMU's, Transformers, LVSB's, Feeder Pillar, Service Pillar Octagonal Poles etc. including getting out the excavated soil and disposal of surplus excavated soil.

58.38

27322

468

... More
Refilling of excavated soil in the foundations, trenches etc. with avialable excavated earth in layers not exceeding 20 cm depth, cosolidating each layer by ramming and watering lead upto 50 M and all lifts and disposal of surplus earth in cable trenches and foundations of equipments.

42.17

5060

120

... More
Laying of cable protective cover as per specification as given below: The concrete slab shall be machine made using semi dry concrete batching plant and cast in a fully automatic PLC controlled concrete batching plant and cast in a fully automatic " Vibro - Press" machine with a high vibration frequency and hydraulic pressure of 40 MT, the size of the slab shall be 480 X 250mm x 50mm, (+/- 2mm) and the concrete grade shall be M30 adhering to IS 456:2000 and shall have a minimum crushing strenght of 30N/mm2( 28 days strength) when tested.

173

10380

60

... More
S.E.T.C. of G.I. earthing pipe, 2500mm long, 40mm nominal dia, class B, perforated for RMU's, Transformers, LVSB's, Feeder Pillar's, Service Pillar's , Streetlight Pillar's, Streetlight Poles . The pit shall be filled with homogenous mixture of 20Kgs of Charcoal, 20Kgs of salt and sand /soil with Brick masonary Chambers The work includes excavation, backfilling & spreading of excavated surplace earth evenly at RMU's, LV Switchboard etc.

15

36660

2444

... More
S.E.T.C. of HDGI flat of size 25mm x 5mm for earthing of RMU's, Transformers, LVSB's, Feeder Pillar's, Service Pillar's , Streetlight Pillar's, Streetlight Poles

75

3600

48

... More
Providing of GI Pipe 150mm, class B for for cable rising on DTC & RCC pole

10

1820

182

... More
Removing of ACSR 'WEASEL' of size ( 6/1/2.59mm)

1.09

3874

3555

... More
Removing of AA ANT conductor

1.56

5174

3317

... More
Removing of AA GNAT conductor

1.56

4822

3091.5

... More
Removing of V Shape X arm with Clamp for 60 Lb/yd rail pole

8

1532

191.5

... More
Removal of 45 KN Disc Insulator with Metal Parts

15

2490

166

... More
Removal of Cutpoint X arm Channel 1.3 mts long with Clamp for 60 Lb/yd rail pole

2

537

268.5

... More
Removal of Guard X arm Channel 1.5 mts long with Clamp for 60 Lb/yd Rail pole 9.0 mts long

9

2659

295.5

... More
Remobval of 11 Kv pin Insulator with HDGI pin

18

1368

76

... More
Removal of LT Pin Insulator woith HDGI pin

40

3460

86.5

... More
Removal of LT shackle Insulator with Metal Parts

53

5512

104

... More
Removal of 4 Pin X arm Angle type with Clamps for 60lb/yd Rail pole

14

1904

136

... More
Removal of 2 Pin Xarm Angle type with Clamps for 60lb/yd rail pole

14

1680

120

... More
Removal of 4 Pin X arm Angle type with Clamps for 9.0mts long RCC pole

6

816

136

... More
Removal of 2 Pin Xarm Angle type with Clamps for 9.0mts long RCC pole

6

720

120

... More
Removal of 60 lb /yd rail pole 9.0mts long

10

22040

2204

... More
Removal of 9.0 mts long RCC pole

4

8816

2204

... More
Removal of 11 mts long RCC pole

1

4300

4300

... More
Removal and restringing of ANT Conductor

0.24

2388

9951

... More
Removal and restringing of GNAT Conductor

0.24

2225

9274.5

... More
Removal & Restringing of RACOON conductor

0.72

11160

15501

... More
Removing & Re-erection of 3 phase, 50Hz, 11/0.433KV, 200KVA, Distribution Transformer complete with Level -II losses, copper winding with Bi-metallic terminal connectors Energy efficiency -Level-II as per IS:1180(Part-I):2014 suitable for outdoor use and for plinth mounting of approved make .moval & Reerection of 150KVA DTC

1

23457

23457

... More
Removal of stay clamp SA for 11 mts long RCC pole

1

49

49

... More
Removal of stay clamp for 60lb/yd rail pole for 9.0 mts long RCC pole

1

39

39.5

... More
Removal of HDGI structural material

260

6110

23.5

... More
Removal & Reerection of MS Distribuition Box

1

13192

13192.5

... More
Removal of Lightening Arrester 9kv 5 kA for DTC

3

261

87

... More
Removal of 11 KV 200 Amps GOAB Switch

1

1985

1985.5

... More
Removal Of 11 KV 200 Amps HG Fuse Unit

1

1684

1684

... More
Removal of 3.5 C X 240 Sq.mm XLPE Al. Armoured Cable

22

2992

136

... More
Removal of 3.5 C X 120 Sq.mm XLPE Al. Armoured Cable

36

3168

88

... More
Removing & Reerection of Distribution Transformer Metering Unit, with DLMS protocol energy meter

1

1608

1608

... More
Removing & Reerection of 11 KV 630 Amps RMU .2LB+ 1 CB

2

29160

14580

... More
Removing & Rerection of LV switchboard for 200 KVA DTC

1

18750

18750

... More
Removing & Re-erection of 4 Way Feeder pillar

1

7224

7224

... More
Removing & re - erection of Streetlight Service pilllar

1

5919

5919

... More
Removing & re-erection of 50 W LED streetlight fixture

13

7800

600

... More
Removing & re erection of Bent pipe 1.5 mts length

13

1735

133.5

... More
Removing of streetlight clamps ( top/ Bottom)

13

305

23.5



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.