Electricity Department Tender
View complete overview of Goa Electricity Department Tender
Costs
EMD
₹ 31,003Document Cost
₹ 500Tender Fee
₹ 3,100
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2023_ED_13058_1Bid Award Id
ViewTender No
tender 42(23-24)/DIV-VI DT 22/12/23Tender Authority
Electricity Department ViewPurchaser Address
-Website
http://eprocure.goa.gov.in
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
BOQ Items
Supply and laying of unarmoured single core 300sqmm XLPE 1.1 KV grade to be laid from transformer to Distribution Box
44
20988
477
XLPE cable armoured 3 ½ C X 185 sq.mm 1.1 KV Grade
30
40020
1334
ACSR conductor 'WEASEL' 6 +1 / 2.59 mm nominal aluminium area 30mm² (139 amps max. at 45° C) for Ab switch
0.25
8352
33409
Distribution Transformer Metering Unit
1
25688
25688
FRP Fencing complete with Gate as per specification for Distribution Transformer (Size 3Mx3Mx2M) with Concreting for FRP Fencing supports with plinth (0.3x0.3x0.5) Cu.m. x 12 nos. Each ratio 1:3:6
1
71167
71167
Modem
1
6000
6000
Enamelled Danger board 11000 Volts:
The plate should be made from mild steel at least 1.6mm thick and vitreous enamelled white with letters, figures and convectional skull and bones in signal red color on the front side. The rear side of the plate shall be enamelled. All lettering should be centrally spaced. The corners of the plates should be rounded off.
Size" 250mm x 200 mm. (as per drawing no. EE-II-3/2001, CEE/E/490)
4
992
248
Earthing complete with 40mm GI Pipe, 2.5 mts long alongwith 20 kgs each salt, charcoal complete.
8
21840
2730
3 WAY RMU, 11KV, 630A, 21 kA 3Sec, SF6 Outdoor RMU – 2LBS + 1CB
Extensible/Non-Extensible Two (2) Motor operated load break switches (LBSs) with Manual operated earthing switches in SF6 and One (1) vacuum circuit breaker with Electrical closing and tripping along with disconnector and earthing switches SCADA Compatible and base channel. Battery charger along with batteries required for Electrical operations of RMU is in the scope of the Bidder. Each module shall consist of VPIS, FPI in LBS Module (N-1) but not less than 1 no’s per RMU. Suitable arrangement for mounting FRTU, modem or Ethernet Switch/LIU along with battery, battery charger shall be provided in RMU.
1
565000
565000
Pinth for 100KVA Transformer 1 NO Providing and laying in position cement concrete 1:2:4 (1 cement : 2 coarse sand: 4 graded granitic or basaltic stone aggregate 40 m) nominal size for foundations.
2.24
12443
5555
Centering and shuttering including struttings, propping etc and removal of formwork .
14.25
8022
563
12mm cement plaster 1:4 (1 - cement: 4 - fine sand) for foundations.
11.82
1737
147
Brick work using common burnt clay building bricks in cement mortar 1:4 (1 - cement: 4 - coarse sand) in foundation and plinth (b) with bricks of class designation 75 Kgs/sq.cm (wire cut bricks).
1.4
10382
7416
Supply, storage transportation to work site, laying termination, testing and commissioning of XLPE cable of voltage 11 KV 3 core 300 Sq.mm excluding cable end termination.( 2 Runs)
75
175350
2338
Supply, storage transportation to work site, laying termination, testing and commissioning of XLPE cable of voltage 11 KV 3 core 95 Sq.mm excluding cable end termination.
20
22540
1127
XLPE Indoor heat shrinkable Termination Kit suitable for 300 sq. mm , 11 KV XLPE cable
2
17680
8840
HS. 11KV straight through joint 3 core 240 to 400 sqmm
2
59118
29559
XLPE Indoor heat shrinkable Termination Kit suitable for 95 sq. mm , 11 KV XLPE cable
1
6731
6731
XLPE Outdoor heat shrinkable Termination Kit suitable for 95 sq. mm , 11 KV XLPE cable
1
10152
10152
Supply & laying of sand.
9
19530
2170
RCC protective covers of size 600mm long x 250mm width and 50mm thick capable of bearing load of 135Kg. And covered with earth/ sand upto depth of 0.15mts. Confirming to IS 1255-1967 at non-road crossing. (as per CEE approved drawing)
16
2032
127
RCC Cable route marker (400 x 900 x 100mm) (as per CEE approved drawing)
4
2112
528
Supply and spreading of 40/20mm basaltic or granitic stone aggregate in the switchyard
1.2
2704
2254
GI Pipe 150mm, class B
12
20172
1681
G.I. Nuts & Bolts 100x16mm
2.4
547
228
GI flat 25x5mm
45
5220
116
COST OF ERECTION
-
-
-
100 KVA 11KV/0.4KV Distribution Transformers level II losses, Alluminium Winding, with Bimetallic Terminal Connectors, Energy Efficiency Level-II as per IS: 1180 (Part-I): 2014
1
11017
11017
Supply and laying of unarmoured single core 300sqmm XLPE 1.1 KV grade to be laid from transformer to Distribution Box
44
9592
218
XLPE cable armoured 3 ½ C X 185 sq.mm 1.1 KV Grade
30
6840
228
Aluminium Crimping lug 300 sq.mm
8
808
101
Aluminium Crimping lug 95 sq.mm
2
130
65
Aluminium Crimping lug 185 sq.mm
6
570
95
Distribution Boxes (M.S) with 200Amps MCCB & Kit-Kat fuses for 100KVA Distribution Transformers.
As per drawing No.CEE/E-689 Revision No.3 alongwith 12 nos. of 200A Kitkat Porcelain fuse carrier and base with extended terminals conforming in general to drawing No.EE-II/7/2002 with 1 no. moulded case circuit breaker (MCCB), 415V, AC, 50Hz with extended terminals conforming to IS 13947-2 as amended upto date.
1
4687
4687
ACSR conductor 'WEASEL' 6 +1 / 2.59 mm nominal aluminium area 30mm² (139 amps max. at 45° C) for Ab switch
0.25
1777
7110
Supply and erection of L.T. Shackle insulators: Brown glazed shackle insulators of size 100mm x 115mm conforming to fig.No.4 and type 2 of IS: 1445/77 as amended upto date. Minimum failing load shall be 16kN.
20
2080
104
Supply and erection of Metal parts for L.T. Shackle insulators:
20
2080
104
Distribution Transformer Metering Unit
1
1072
1072
FRP Fencing complete with Gate as per specification for Distribution Transformer (Size 3Mx3Mx2M) with Concreting for FRP Fencing supports with plinth (0.3x0.3x0.5) Cu.m. x 12 nos. Each ratio 1:3:6
1
33667
33667
Enamelled Danger board 11000 Volts:
The plate should be made from mild steel at least 1.6mm thick and vitreous enamelled white with letters, figures and convectional skull and bones in signal red color on the front side. The rear side of the plate shall be enamelled. All lettering should be centrally spaced. The corners of the plates should be rounded off.
Size" 250mm x 200 mm. (as per drawing no. EE-II-3/2001, CEE/E/490)
4
228
57
Earthing complete with 40mm GI Pipe, 2.5 mts long alongwith 20 kgs each salt, charcoal complete.
8
19552
2444
3 WAY RMU, 11KV, 630A, 21 kA 3Sec, SF6 Outdoor RMU – 2LBS + 1CB
Extensible/Non-Extensible Two (2) Motor operated load break switches (LBSs) with Manual operated earthing switches in SF6 and One (1) vacuum circuit breaker with Electrical closing and tripping along with disconnector and earthing switches SCADA Compatible and base channel. Battery charger along with batteries required for Electrical operations of RMU is in the scope of the Bidder. Each module shall consist of VPIS, FPI in LBS Module (N-1) but not less than 1 no’s per RMU. Suitable arrangement for mounting FRTU, modem or Ethernet Switch/LIU along with battery, battery charger shall be provided in RMU.
1
9720
9720
Earthwork excavation in foundations trenches (not exceeding 1.5mts in width or 10mm² on plan) including opening of roads, chamber/pavements & soiling , ramming, levelling of bottoms, making free from stones including removing out the excavated soil/material as directed within a lead of 40mts in laterite rock soil (1.1X 0.6 X 90)
15
7020
468
Supply, storage transportation to work site, laying termination, testing and commissioning of XLPE cable of voltage 11 KV 3 core 300 Sq.mm excluding cable end termination.( 2 Runs)
75
25650
342
Supply, storage transportation to work site, laying termination, testing and commissioning of XLPE cable of voltage 11 KV 3 core 95 Sq.mm excluding cable end termination.
20
3980
199
XLPE Indoor heat shrinkable Termination Kit suitable for 300 sq. mm , 11 KV XLPE cable
2
5096
2548
HS. 11KV straight through joint 3 core 240 to 400 sqmm
2
7426
3713
XLPE Indoor heat shrinkable Termination Kit suitable for 95 sq. mm , 11 KV XLPE cable
1
2538
2538
XLPE Outdoor heat shrinkable Termination Kit suitable for 95 sq. mm , 11 KV XLPE cable
1
2648
2648
Back Filling up of available excavated earth (excluding rock/stones) in trenches, plinth, sides, foundations etc. in layer not exceeding 0.2 mtrs. depth consolidation each deposited layer by ramming and watering (1 x 0.4 x 90)
5
600
120
Disposal of surplus excavated soil/material by mechanical transportation including loading, unloading, starting leveling as directed up to a distance of 2.5 km
3
377
125.82
RCC protective covers of size 600mm long x 250mm width and 50mm thick capable of bearing load of 135Kg. And covered with earth/ sand upto depth of 0.15mts. Confirming to IS 1255-1967 at non-road crossing. (as per CEE approved drawing)
16
1344
84
RCC Cable route marker (400 x 900 x 100mm) (as per CEE approved drawing)
4
1024
256
GI Pipe 150mm, class B
12
2184
182
G.I. Nuts & Bolts 100x16mm
2.4
72
30
GI flat 25x5mm
45
2160
48
Evaluation Notes How It Works ?