Electricity Department Tender
View complete overview of Goa Electricity Department Tender
Costs
EMD
₹ 4,90,769Document Cost
₹ 1,500Tender Fee
₹ 6,000
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2024_ED_13664_1Bid Award Id
ViewTender No
Tender 14(23-24)Tender Authority
Electricity Department ViewPurchaser Address
-Website
http://eprocure.goa.gov.in
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
BOQ Items
Sand for cushioning of HT underground cables.
(Dimesions : - 0.2*0.4*1000)
80
152960
1912
Supply , Laying , Testing & Commissioning of 3 x 300 sq.mm. 11 KV XLPE (Type A2XFY, FRLS) armoured, aluminium power Cable along with cable glands complete through HDD Pipe as per technical specification by HDD Method
1750
4091500
2338
Supply , Laying , Testing & Commissioning of 3 x 300 sq.mm. 11 KV XLPE (Type A2XFY, FRLS) armoured, aluminium power Cable along with cable glands complete as per technical specification in open trench.
1025
2396450
2338
Supply of straight through joint for 300sq.mm cable
12
354708
29559
Supply and laying of underground cable protective cover as per specification as given below:
The concrete slab shall be machine made using semi dry concrete that is batched in a fully automatic PLC controlled concrete batching plant and cast in a fully automatic "Vibro Press" machine with a high vibration frequency and hydraulic pressure of 40 MT, the size of the slab shall be 480mm x 250 mm x 50 mm, (+/- 2 mm) and the concrete grade shall be M30 adhering to IS 456:2000 and shall have a minimum crushing strength of 30 N/mm2 (28 days strength) when tested.
2083
395770
190
Warning tape.
1
15000
15000
Supply of 11KV, 630 Amps, Outdoor, SF6 Ring Main Unit with two Load Break Switches and one Circuit Breaker .Extensible/Non-Extensible Two (2) Motor operated load break switches (LBSs) with Manual operated earthing switches in SF6 and One (1) vacuum circuit breaker with Electrical closing and tripping along with disconnector and earthing switches SCADA Compatible and base channel. Battery charger along with batteries required for Electrical operations of RMU is in the scope of the Bidder. Each module shall consist of VPIS, FPI in LBS Module (N-1) but not less than 1 no’s per RMU. Suitable arrangement for mounting FRTU, modem or Ethernet Switch/LIU along with battery, battery charger shall be provided in RMU.
12
6780000
565000
Supply of 11KV, 630 Amps, Outdoor, SF6 Ring Main Unit with three Load Break Switches.Extensible/Non Extensible Three (3) Motor operated load break switches (LBSs) with Manual operated earthing switches in SF6 SCADA Compatible and base channel. Battery charger along with batteries required for Electrical operations of RMU is in the scope of the Bidder. Each module shall consist of VPIS, FPI in LBS Module (N-1) but not less than 1 no’s per RMU. Suitable arrangement for mounting FRTU , modem or Ethernet Switch/LIU along with battery, battery charger shall be provided in RMU.
3
1632000
544000
Supply of 11KV, 3 core, 95sq.mm, Al conductor, XLPE, insulated, armoured cable (from the RMU to the transformer)
860
969220
1127
Supply of 11KV 3 phase indoor terminating kit to be used with cables - 300sq.mm.
29
256360
8840
Supply of 11KV 3 phase indoor terminating kit to be used with cables - 95sq.mm.
12
80772
6731
Supply of 11KV 3 phase outdoor terminating kit including sockets at 11KV end of DT to be used with cables as per - 95sq.mm.
12
121824
10152
Supply of Cable Route marker RCC Cable route marker (400 x 900 x 100mm) (as per CEE approved drawing, copy enclosed)
10
5280
528
Earthing complete with 40mm GI Pipe, 2.5 mts long alongwith 20 kgs each salt, charcoal complete.Earthing complete with 40mm GI Pipe, 2.5 mts long alongwith 20 kgs each salt, charcoal complete.
26
70980
2730
Supply of HDGI flat of size 25mm x 5mm for earthing.
220
25520
116
Erection Cost
-
-
-
laying of 11 KV /LT UG cabels by trenchless technology by adopting horizontal directional drilling (HDD method). The work includes preparation of site, Boring as well as drawing of cable in Hard/Laterite stone with minimum 8" bore size, including supply and erection of HDPE pipe 110mm PN6 PE100 Thickness 6 mm
1700
5185000
3050
Earthwork in excavation by mechanical means (hydraulic excavator)/manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sq.m on plan) including disposal of excavated earth lead upto 50 m and lift upto 1.5m disposed earth to be leveled and neatly dressed including providing barricading, danger lighting guarding as directed in : Hard Soil
(Dimensions : -1.1*0.4*1000) for TRENCH AND RMU
440
335720
763
Erection of RCC Hume Pipe 100mm dia with required no. of collars, for road crossing (100 mm dia NP2 Pipe as per GSR 2020 (Roads) item nn 1910)
180
13860
77
Erection of GI Pipe 100mm, class B for nalla crossing and for cable rising on D.P. of DTC
160
14720
92
Erection , Laying , Testing & Commissioning of 3 x 300 sq.mm. 11 KV XLPE (Type A2XFY, FRLS) armoured, aluminium power Cable along with cable glands complete as per technical specification in open trench.
1025
350550
342
Erection of straight through joint for 300sq.mm cable
12
44556
3713
Erection and laying of underground cable protective cover as per specification as given below:
The concrete slab shall be machine made using semi dry concrete that is batched in a fully automatic PLC controlled concrete batching plant and cast in a fully automatic "Vibro Press" machine with a high vibration frequency and hydraulic pressure of 40 MT, the size of the slab shall be 480mm x 250 mm x 50 mm, (+/- 2 mm) and the concrete grade shall be M30 adhering to IS 456:2000 and shall have a minimum crushing strength of 30 N/mm2 (28 days strength) when tested.
2083
147893
71
Refilling the pipeline/foundation trenches plinth sides, foundation etc. with available excavated earth in layers not exceeding 20 cm depth consolidating each layer ramming and watering lead upto 50 M and all lifts and disposal of surplus earth as directed by Engineer in Charge
(Dimesions : - 0.9*0.4*1000)
360
43200
120
Disposal of earth at a distance of 3000 mts
(Dimesions : - 0.2*0.4*1000)
80
10065
125.82
Erection of 11KV, 630 Amps, Outdoor, SF6 Ring Main Unit with two Load Break Switches and one Circuit Breaker .Extensible/Non-Extensible Two (2) Motor operated load break switches (LBSs) with Manual operated earthing switches in SF6 and One (1) vacuum circuit breaker with Electrical closing and tripping along with disconnector and earthing switches SCADA Compatible and base channel. Battery charger along with batteries required for Electrical operations of RMU is in the scope of the Bidder. Each module shall consist of VPIS, FPI in LBS Module (N-1) but not less than 1 no’s per RMU. Suitable arrangement for mounting FRTU, modem or Ethernet Switch/LIU along with battery, battery charger shall be provided in RMU.
12
116640
9720
Erection of 11KV, 630 Amps, Outdoor, SF6 Ring Main Unit with three Load Break Switches.Extensible/Non Extensible Three (3) Motor operated load break switches (LBSs) with Manual operated earthing switches in SF6 SCADA Compatible and base channel. Battery charger along with batteries required for Electrical operations of RMU is in the scope of the Bidder. Each module shall consist of VPIS, FPI in LBS Module (N-1) but not less than 1 no’s per RMU. Suitable arrangement for mounting FRTU , modem or Ethernet Switch/LIU along with battery, battery charger shall be provided in RMU.
3
29160
9720
Erection of 11KV, 3 core, 95sq.mm, Al conductor, XLPE, insulated, armoured cable (from the RMU to the transformer)
860
171140
199
Erection of 11KV 3 phase indoor terminating kit to be used with cables - 300sq.mm.
29
73892
2548
Erection of 11KV 3 phase indoor terminating kit to be used with cables - 95sq.mm.
12
30456
2538
Erection of 11KV 3 phase outdoor terminating kit including sockets at 11KV end of DT to be used with cables as per - 95sq.mm.
12
31776
2648
Erection of Cable Route marker RCC Cable route marker (400 x 900 x 100mm) (as per CEE approved drawing, copy enclosed)
10
2560
256
Earthing complete with 40mm GI Pipe, 2.5 mts long alongwith 20 kgs each salt, charcoal complete.Earthing complete with 40mm GI Pipe, 2.5 mts long alongwith 20 kgs each salt, charcoal complete.
26
63544
2444
Erection of HDGI flat of size 25mm x 5mm for earthing.
220
10560
48
Removing OfOld RCC Poles 9 Mts Long Pole
30
66120
2204
Removing Of Old RCC Poles 11 Mts Long RCC Poles /rail pole
10
43000
4300
Removing of 11 KV ACSR Weasel Conductor
2.7
9598
3555
Removing of 11 KV ACSR Racoon Conductor
2.2
11367
5167
Removing of 11 KV GOAB Switch
5
9927
1985.5
Removing of 11 kv Pin insulator with G.I pin
90
6840
76
Removing of 11 kv Disc insulator with M.P.
45
7470
166
Removing of V Shape Cross Arm Channel
40
6760
169
Removing of Top Fitting for Pin Insulators
30
3420
114
Removing of Guarding Channel
10
2730
273
Removing of Stay Set
10
8895
889.5
Errection cost for RMU
-
-
-
Earthworkin excavation by mechanical means (Hydraulic excavator)/manual means over areas (exceeding 30cm in depth,1.5m in width as well as 10sq.m on plan) including disposal of excavated eath lead upto 50m and lift upto 1.5m disposed earth to be leveled and neatly dressed including providing barricading, danger lightting guarding as directed in :
b) All types of ordinary rock including all types of laterite rock , blasting prohibited.
25.35
16198
639
Refilling the pipeline/foundation trenches plinth sides, foundation etc. with available excavated earth in layers not exceeding 20 cm depth consolidating each layer ramming and watering lead upto 50 M and all lifts and disposal of surplus earth as directed by Engineer In Charge
17.1
4189
245
Rubble packing with hard laterite stone under floors including watering ramming and consolidating etc.in pipeline trenches and other foundation complete.
2.25
4974
2211
Providing & laying cement concrete 1:2:4 (1 cement : 2 coarse : 4graded granitic or basaltic stone aggrt.20mm.nominal size) excluding cost of centering, shuttering and finishing in :
a) All works upto plinth level.
8.7
59247
6810
Centering and shuttering including struttings,propping etc. and removal o framework for :
(i) Foundations , footings, bases for columns.
65.25
26556
407
12mm cement plaster 1:4 (1 cement :4 fine sand)
44.55
9934
223