Electricity Department Tender

View complete overview of Goa Electricity Department Tender

Electricity Department Tender

Works
Electrical Generators And Transformers
Electrical and Electronics
Eprocure
Opening Date2 Jan 2024
Closing Date30 Jan 2024
Tender Amount₹ 16,59,926 
Notes
Download

Costs

  • EMD

    ₹ 33,199
  • Document Cost

    ₹ 500
  • Tender Fee

    ₹ 3,320

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
11 KV rated voltange GOAB switches tilting type, outdoor, manually operated, triple pole, single break, conforming to IS: 9921-Part 1 to V as amended up to date and detailed specification eclosed herewith. Each set shall comprise of six pedestal and three tilting post insulators. Insulator should be factory cemented by the manufacturer of the insulators and have minimum 320 mm creepage distance and AB switchs contacts shall be of copper/ copper alloy. The AB switch shall be of following current rating: 200 A

1

23535

23535

... More
11 KV , 200 A Horn gap fuse unit (Set of three) shall be as per enclosed drg No. CEE/E-786. Revision 3 and detailed specifications enclosed herewith.

1

10450

10450

... More
9 KV, 5 KA nominal discharge current metal oxide gapless distribution class Lightning arrestor conforming to IEC-600994-4 and IS: 3070 part 3 1993 as amended upto date suitable for 11 KV 50 HZ effectively earthed neutral system with necessary mounting arragements and connector suitable to connect ASCR conductor upto overall diameter 12.30 mm

3

9099

3033

... More
HDGI structure material \\. Each trasformer centre DP consist of HDGI structure material as follows: a) GI channel ISMC 75x40x7.3mm 2.75 mtrs long 2 pieces for incoming line & installation of disc insulators b) GI channel ISMC75x40x7.3mm 2.75mtrs long 2 pieces for GOAB switch c) GI channel ISMC 75x40x7.3mm 2.75 mtrs long 2 pieces for HG fuses d) GI channel ISMC 75x40x7.3mm 2.75 mtrs long 2 pieces for installation of lightening arrestor e) GI channel ISMC 100x50x7.3mm 2.75 mtrs long 2 pieces for installation of Trasformer f) GI channel ISMC 75x40x7.3mm 2.75 mtrs long 2 pieces for side support of trasformer g) GI channel ISMC 75x40x7.3mm 2.75 mtrs long 4 pieces for installation of any other items h) GI channel ISMC 100x40x7.3mm 0.52 mtrs long 2 pieces for installation of Transformer base channel

260

43940

169

... More
Supply & Erection of 100KVA 11/0.433KV 3 phase outdoor type ,oil immeresed Aluminium wound level II distribution trasnfromers

1

247700

247700

... More
Supply & erection of LT/11KV Stay set complete 9 Mts long RCC pole

3

13099

4366.54

... More
HDGI Top Insulator fitting Cross arm ISMC channel 75 x 40 mm, 0.7 mtr with nut bolts long for 11 mts long RCC pole

2

2648

1324.2

... More
Supply & erection of HDG 11 KV 'V' Shape cross arm of channel ISMC 75 x 40 x 7.3 mm. with HDG Clamp & HDG nut bolts etc. for 11 Mtr. long RCC Pole as pet drg no. CEE/E - 408-R1

2

3948

1974.2

... More
HDG L.T. 4 pin cross arm Channel type as above with HDG clamps & HDG nut bolts etc for 11mts long RCC pole as per drg No.CEE/E-491 and drg no. CEE/E-524

2

3228

1614.2

... More
HDG L.T. 2 pin cross arm Channel type as above with HDG clamps & HDG nut bolts etc for 11 mts long RCC pole as per drg No.CEE/E-491 and drg no. CEE/E-524

1

1074

1074.2

... More
HDG L.T. 4 pin cross arm Channel type as above with HDG clamps & HDG nut bolts etc for 9 mts long RCC pole as per drg No.CEE/E-491 and drg no. CEE/E-524

5

7331

1466.2

... More
HDG L.T. 2 pin cross arm Channel type as above with HDG clamps & HDG nut bolts etc for 9 mts long RCC pole as per drg No.CEE/E-491 and drg no. CEE/E-524

4

3704

926.2

... More
11 KV brown glazed porcelain Pin Insulator with minimum failing load of 5 KN and the minimum creepage distance of 320mm conforming to IS 731-1971 as amended upto date. And forged GI pin conforming to IS 2486 part 1 & 2 as amended upto date suitable for 11 KV glazed porcelain pin insulators conforming to IS 731/71 as amended upto date. GI pin shall conform to reference S-165 N fig 5 of IS 2486/(part-II)/74 as amended upto date. Dimension X in said fig shall be 150mm (screwed 100mm). Pin shall be supplied along with one suitable GI hexagonal nut and GI spring washer. Minimum failing load of pin shall be 10 KN.

6

4158

693

... More
LT brown glazed shackle Insulator of size 100 mm x 115 mm conforming to fig No. 4 and type 2 fo IS: 1445/77 as amended upto date. Minimum failing load shall be 16 KN with GI hardware suitable for LT shackle insulator of size 100 x 115 mm conforming to type 2 fig 4 of IS: 1445/77 as amended upto date. Hardware or fitting shall conform to fig 4 of IS: 7935-1975 as amended upto date comprise fo 2 GI strips, 2 GI bolts and 2 nuts with spring washers.

41

15252

372

... More
L.T. brown glazed porcelain pin insulators of size 100mmx70mm conforming to type 1 fig 1 of IS: 1445/1977 with amendment 2 of Feb 1981 (second revision) as amended upto date. Minimum failing load shall be 3.5 KN with Forged GI pin conforming to IS 7935/1975 as amended upto date suitable for LT porcelain pin insulator type 1 conforming to fig 1 of IS: 1445/77 with amendment no 2 feb 1981, of size 100 x 70 mm. GI pin shall comprise of GI nut and spring washer and conform to fig No 2 of IS: 7935/1975. Minimum failing load of pin shall be 3.5 KN

9

2367

263

... More
ACSR Conductor Hard drawn stranded aluminium conductor with galvanized steel wire reinforced conforming to IS: 398(PartII-96) amended upto date of the following sizes. WEASEL 6/1/2.59 (nominal aluminium area 30 Sq.mm.) (139 amp max at 45 °C) for line

0.3

10022

33409

... More
Earthing complete with chamber as per drg/ No. CEE/E-830. Each earthing should consist as follows a) 40 mm. Dia 2.5 mtr long, class B GI pipe 1 No. b)HDGI nut bolts, clamps 1 set, c)Brick masonary-0.108 Cu.mts d) PVC pipe 50mm dia- 0.2mtr e) Salt-20 Kgs f) Charcoal-20 Kgs g) Excavation-0.864 Cu. Mtr h) refilling-0.74 Cu.mtr as per drg. No.CEE/E-830.

6

16380

2730

... More
XPLE insulated single core unarmoured cable 50 mm2 for DP earthing.

55

4565

83

... More
AA"ANT" conductor

0.96

46162

48086

... More
AA"GNAT" conductor

0.85

21499

25293

... More
MS Distribution box as per drg No. CEE/E-689 Revision No. 3 along with MCCB 400 A, Bus bar made out of Aluminium strips 40 x 10 mm, kit kat fuses for 4 feeder arrangement

1

63140

63140

... More
XLPE 1.1KV Armored single core unarmoured cable 185 mm²

48

11760

245

... More
XLPE 1.1KV 3 & 1/2 XLPE Armoured cable 120 mm²

36

32868

913

... More
Enamelled danger boards 11000 Volts ,250mm x 200mmm as per drg no. CEE/E-490

2

496

248

... More
Aluminium crimping Lugs shall conform to IS: 8309-1976 as amended upto date. Lugs shall be made of aluminium of grade IE of IS: 5082/1969 suitable for aluminium cable fo sizes 185 Sq.mm.

8

624

78

... More
Aluminium crimping Lugs shall conform to IS: 8309-1976 as amended upto date. Lugs shall be made of aluminium of grade IE of IS: 5082/1969 suitable for aluminium cable fo sizes 120 Sq.mm.

9

486

54

... More
Aluminium crimping Lugs shall conform to IS: 8309-1976 as amended upto date. Lugs shall be made of aluminium of grade IE of IS: 5082/1969 suitable for aluminium cable fo sizes 95 Sq.mm.

3

120

40

... More
Aluminium crimping Lugs shall conform to IS: 8309-1976 as amended upto date. Lugs shall be made of aluminium of grade IE of IS: 5082/1969 suitable for aluminium cable fo sizes50 Sq.mm.

45

990

22

... More
FRP Fencing complete with Gate as epr specification for distribution transformer (size 4Mx3Mx2M) with Concreting for FRP Fencing supports with plinth (0.3x0.3x0.5)Cu.m.x12nos Each ratio 1;3;6

1

76667

76667

... More
Painting of Pole Numbers

5

521

104.33

... More
3 WAY RMU, 11KV, 630A, 21 kA 3Sec, SF6 Outdoor RMU – 2LBS + 1CB Extensible/Non Extensible Two (2) Motor operated load break switches (LBSs) with Manual operated earthing switches in SF6 and One (1) vacuum circuit breaker with Electrical closing and tripping along with disconnector and earthing switches SCADA Compatible and base channel. Battery charger along with batteries required for Electrical operations of RMU is in the scope of the Bidder. Each module shall consist of VPIS, FPI in LBS Module (N-1) but not less than 1 no’s per RMU, Current Transformer and Numerical Relay with communication in all CB module. Suitable arrangement for mounting FRTU , modem or Ethernet Switch/LIU along with battery, battery charger shall be provided in RMU.Auxiliary PT as per specification shall be provided in RMU.

1

565000

565000

... More
Supply, Erection, Testing & Commissioning of 11KV, 3 core 95 sq.mm A2XFY Aluminium Armoured XLPE Cable

20

22540

1127

... More
Supply, Erection, Testing & Commissioning of of 11 KV Termination kit Indoor 3 core 95 sqmm XLPE

1

6731

6731

... More
Supply, Erection, Testing & Commissioning of of 11 KV Termination kit Outdoor 3 core 95 sqmm XLPE

1

10152

10152

... More
Supply, Erection, Testing & Commissioning of of 11 KV Termination kit Indoor 3 core 300 sqmm XLPE

2

17680

8840

... More
Earthing complete with 40mm GI Pipe, 2.5 mts long alongwith 20 kgs each salt, charcoal complete with brick masonary.

2

8856

4428

... More
Supply & Erection of GI flat of size 25mm x 5mm for earthing.

10

1160

116

... More
Supply & Erection of GI pipe 150mm class B

10

16810

1681

... More
Cost of Erection

-

-

-

... More
Supply & Erection of RCC pole 11 mtr as per the drawing No.CEE/E-698 REV-3 as per annexure confirming to IS 785-1998 as amended upto date. The component used for pole shall conform to following IS amended up to date. 1) Ordinary Port land cement 53 grade IS 12269 2) Aggregate IS 383-1970 3) Torsteel IS 1786-7985 4) MS bar IS 432 p 1 & 2-1982

2

17200

8600

... More
Supply & Erection of RCC pole 9 mtr as per the drawing No.CEE/E-724 REV-3 as per annexure confirming to IS 785-1998 as amended upto date. The component used for pole shall conform to following IS amended up to date. 1) Ordinary Port land cement 53 grade IS 12269 2) Aggregate IS 383-1970 3) Torsteel IS 1786-7985 4) MS bar IS 432 p 1 & 2-1982

3

13224

4408

... More
11 KV rated voltange GOAB switches tilting type, outdoor, manually operated, triple pole, single break, conforming to IS: 9921-Part 1 to V as amended up to date and detailed specification eclosed herewith. Each set shall comprise of six pedestal and three tilting post insulators. Insulator should be factory cemented by the manufacturer of the insulators and have minimum 320 mm creepage distance and AB switchs contacts shall be of copper/ copper alloy. The AB switch shall be of following current rating: 200 A

1

3971

3971

... More
11 KV , 200 A Horn gap fuse unit (Set of three) shall be as per enclosed drg No. CEE/E-786. Revision 3 and detailed specifications enclosed herewith.

1

3368

3368

... More
9 KV, 5 KA nominal discharge current metal oxide gapless distribution class Lightning arrestor conforming to IEC-600994-4 and IS: 3070 part 3 1993 as amended upto date suitable for 11 KV 50 HZ effectively earthed neutral system with necessary mounting arragements and connector suitable to connect ASCR conductor upto overall diameter 12.30 mm

3

522

174

... More
HDGI structure material \\. Each trasformer centre DP consist of HDGI structure material as follows: a) GI channel ISMC 75x40x7.3mm 2.75 mtrs long 2 pieces for incoming line & installation of disc insulators b) GI channel ISMC75x40x7.3mm 2.75mtrs long 2 pieces for GOAB switch c) GI channel ISMC 75x40x7.3mm 2.75 mtrs long 2 pieces for HG fuses d) GI channel ISMC 75x40x7.3mm 2.75 mtrs long 2 pieces for installation of lightening arrestor e) GI channel ISMC 100x50x7.3mm 2.75 mtrs long 2 pieces for installation of Trasformer f) GI channel ISMC 75x40x7.3mm 2.75 mtrs long 2 pieces for side support of trasformer g) GI channel ISMC 75x40x7.3mm 2.75 mtrs long 4 pieces for installation of any other items h) GI channel ISMC 100x40x7.3mm 0.52 mtrs long 2 pieces for installation of Transformer base channel

260

12220

47

... More
Supply & Erection of 100KVA 11/0.433KV 3 phase outdoor type ,oil immeresed Aluminium wound level II distribution trasnfromers

1

11017

11017

... More
Supply & erection of LT/11KV Stay set complete 9 Mts long RCC pole

3

7397

2465.88

... More
HDGI Top Insulator fitting Cross arm ISMC channel 75 x 40 mm, 0.7 mtr with nut bolts long for 11 mts long RCC pole

2

610

305

... More
Supply & erection of HDG 11 KV 'V' Shape cross arm of channel ISMC 75 x 40 x 7.3 mm. with HDG Clamp & HDG nut bolts etc. for 11 Mtr. long RCC Pole as pet drg no. CEE/E - 408-R1

2

830

415

... More
HDG L.T. 4 pin cross arm Channel type as above with HDG clamps & HDG nut bolts etc for 11mts long RCC pole as per drg No.CEE/E-491 and drg no. CEE/E-524

2

676

338

... More
HDG L.T. 2 pin cross arm Channel type as above with HDG clamps & HDG nut bolts etc for 11 mts long RCC pole as per drg No.CEE/E-491 and drg no. CEE/E-524

1

309

309

... More
HDG L.T. 4 pin cross arm Channel type as above with HDG clamps & HDG nut bolts etc for 9 mts long RCC pole as per drg No.CEE/E-491 and drg no. CEE/E-524

5

1590

318

... More
HDG L.T. 2 pin cross arm Channel type as above with HDG clamps & HDG nut bolts etc for 9 mts long RCC pole as per drg No.CEE/E-491 and drg no. CEE/E-524

4

1156

289

... More
11 KV brown glazed porcelain Pin Insulator with minimum failing load of 5 KN and the minimum creepage distance of 320mm conforming to IS 731-1971 as amended upto date. And forged GI pin conforming to IS 2486 part 1 & 2 as amended upto date suitable for 11 KV glazed porcelain pin insulators conforming to IS 731/71 as amended upto date. GI pin shall conform to reference S-165 N fig 5 of IS 2486/(part-II)/74 as amended upto date. Dimension X in said fig shall be 150mm (screwed 100mm). Pin shall be supplied along with one suitable GI hexagonal nut and GI spring washer. Minimum failing load of pin shall be 10 KN.

6

912

152

... More
LT brown glazed shackle Insulator of size 100 mm x 115 mm conforming to fig No. 4 and type 2 fo IS: 1445/77 as amended upto date. Minimum failing load shall be 16 KN with GI hardware suitable for LT shackle insulator of size 100 x 115 mm conforming to type 2 fig 4 of IS: 1445/77 as amended upto date. Hardware or fitting shall conform to fig 4 of IS: 7935-1975 as amended upto date comprise fo 2 GI strips, 2 GI bolts and 2 nuts with spring washers.

41

8528

208

... More
L.T. brown glazed porcelain pin insulators of size 100mmx70mm conforming to type 1 fig 1 of IS: 1445/1977 with amendment 2 of Feb 1981 (second revision) as amended upto date. Minimum failing load shall be 3.5 KN with Forged GI pin conforming to IS 7935/1975 as amended upto date suitable for LT porcelain pin insulator type 1 conforming to fig 1 of IS: 1445/77 with amendment no 2 feb 1981, of size 100 x 70 mm. GI pin shall comprise of GI nut and spring washer and conform to fig No 2 of IS: 7935/1975. Minimum failing load of pin shall be 3.5 KN

9

1557

173

... More
ACSR Conductor Hard drawn stranded aluminium conductor with galvanized steel wire reinforced conforming to IS: 398(PartII-96) amended upto date of the following sizes. WEASEL 6/1/2.59 (nominal aluminium area 30 Sq.mm.) (139 amp max at 45 °C) for line

0.3

2133

7110

... More
Earthing complete with chamber as per drg/ No. CEE/E-830. Each earthing should consist as follows a) 40 mm. Dia 2.5 mtr long, class B GI pipe 1 No. b)HDGI nut bolts, clamps 1 set, c)Brick masonary-0.108 Cu.mts d) PVC pipe 50mm dia- 0.2mtr e) Salt-20 Kgs f) Charcoal-20 Kgs g) Excavation-0.864 Cu. Mtr h) refilling-0.74 Cu.mtr as per drg. No.CEE/E-830.

6

14664

2444

... More
XPLE insulated single core unarmoured cable 50 mm2 for DP earthing.

55

3080

56

... More
AA"ANT" conductor

0.96

6368

6634

... More
AA"GNAT" conductor

0.85

5255

6183

... More
MS Distribution box as per drg No. CEE/E-689 Revision No. 3 along with MCCB 400 A, Bus bar made out of Aluminium strips 40 x 10 mm, kit kat fuses for 4 feeder arrangement

1

8795

8795

... More
XLPE 1.1KV Armored single core unarmoured cable 185 mm²

48

8832

184

... More
XLPE 1.1KV 3 & 1/2 XLPE Armoured cable 120 mm²

36

6336

176

... More
Enamelled danger boards 11000 Volts ,250mm x 200mmm as per drg no. CEE/E-490

2

114

57

... More
Aluminium crimping Lugs shall conform to IS: 8309-1976 as amended upto date. Lugs shall be made of aluminium of grade IE of IS: 5082/1969 suitable for aluminium cable fo sizes 185 Sq.mm.

8

760

95

... More
Aluminium crimping Lugs shall conform to IS: 8309-1976 as amended upto date. Lugs shall be made of aluminium of grade IE of IS: 5082/1969 suitable for aluminium cable fo sizes 120 Sq.mm.

9

792

88

... More
Aluminium crimping Lugs shall conform to IS: 8309-1976 as amended upto date. Lugs shall be made of aluminium of grade IE of IS: 5082/1969 suitable for aluminium cable fo sizes 95 Sq.mm.

3

195

65

... More
Aluminium crimping Lugs shall conform to IS: 8309-1976 as amended upto date. Lugs shall be made of aluminium of grade IE of IS: 5082/1969 suitable for aluminium cable fo sizes50 Sq.mm.

45

2295

51

... More
FRP Fencing complete with Gate as epr specification for distribution transformer (size 4Mx3Mx2M) with Concreting for FRP Fencing supports with plinth (0.3x0.3x0.5)Cu.m.x12nos Each ratio 1;3;6

1

35000

35000

... More
Removing of 7.5 Mts long RCC pole

2

3689

1844.5

... More
Removing of LT 4 pin cross arm of 75x40 channel with clamps & nut bolt for 7.5 mtr RCC pole

2

305

152.5

... More
Removing of LT 2-pin cross arm of 75x40 channel with clamps & nut bolts for 7.5 mtr RCC pole

2

276

138

... More
Removing of Pin insulator with GI pin

15

1297

86.5

... More
Removing of AA ANT Conductor

0.85

2819

3317

... More
Removing of AA GNAT Conductor

0.85

2633

3091.5

... More
3 WAY RMU, 11KV, 630A, 21 kA 3Sec, SF6 Outdoor RMU – 2LBS + 1CB Extensible/Non Extensible Two (2) Motor operated load break switches (LBSs) with Manual operated earthing switches in SF6 and One (1) vacuum circuit breaker with Electrical closing and tripping along with disconnector and earthing switches SCADA Compatible and base channel. Battery charger along with batteries required for Electrical operations of RMU is in the scope of the Bidder. Each module shall consist of VPIS, FPI in LBS Module (N-1) but not less than 1 no’s per RMU, Current Transformer and Numerical Relay with communication in all CB module. Suitable arrangement for mounting FRTU , modem or Ethernet Switch/LIU along with battery, battery charger shall be provided in RMU.Auxiliary PT as per specification shall be provided in RMU.

1

9720

9720

... More
Supply, Erection, Testing & Commissioning of 11KV, 3 core 95 sq.mm A2XFY Aluminium Armoured XLPE Cable

20

3980

199

... More
Supply, Erection, Testing & Commissioning of of 11 KV Termination kit Indoor 3 core 95 sqmm XLPE

1

2538

2538

... More
Supply, Erection, Testing & Commissioning of of 11 KV Termination kit Outdoor 3 core 95 sqmm XLPE

1

2648

2648

... More
Supply, Erection, Testing & Commissioning of of 11 KV Termination kit Indoor 3 core 300 sqmm XLPE

2

5096

2548

... More
Earthing complete with 40mm GI Pipe, 2.5 mts long alongwith 20 kgs each salt, charcoal complete with brick masonary.

2

5330

2665

... More
Supply & Erection of GI flat of size 25mm x 5mm for earthing.

10

480

48

... More
Supply & Erection of GI pipe 150mm class B

10

1820

182

... More
Civil Estimate for RMU foundation Earthwork in excavation by mechanical means (hydraulic excavator)/manual means over areas (exceeding 30 cm in depth, 1.5 min width as well as 10 sq.m on plan) including disposal of excavated earth lead upto 50 m and lift upto 1.5m disposed earth to be leveled and neatly dressed including providing barricading, danger lighting guarding as directed in : All types of Ordinary rock including all types of laterite rock, blasting prohibited…………..5.28 Cum Rubble packing with hard laterite stone under floors including watering ramming and consolidating etc. in pipeline trenches and other foundations complete………….0.96 Cum Providing & laying cement concrete 1:3:6 (1 cement: 3 coarse sand: 6 graded granitic or basaltic stone aggrt. 20 mm. nominal size) excluding cost of centering, shuttering and finishing in: All works upto plinth level…………………..0.48 Cum Providing and laying in position (1:11/2:3) Reinforced cement concrete excluding the cost of centering, shuttering, finishing and reinfrocement (1 cement: 1½ coarse sand: 3 graded stone agg 20mm nominal size) All works upto plinth level……..1.81Cum Providing TMT steel reinforcement bars of (SAIL, TATA, VIZAG, JSW Steel Ltd.))(Confirming to IS 1786 of 1986) for RCC work (conforming to I.S. 1786 of 1986) including bending, binding & placing in position in all the floors along with the factory made precast concrete cover blocks of specified sizes whose compressive strength is not less than that of surrounding concrete in the structural member………………..222.42 Kg Centering & shuttering including Strutting, Propping & removal of forms for: Foundations, Footings, Bases for columns…….1.12 Sqm Centering & shuttering including Strutting, Propping & removal of forms for: Vertical surfaces such as retaining walls, return walls, Partitions, walls (any thickness) including attached Pilasters, Buttresses, Plinth and string courses, Fillets and the like…………………………..11.70 Sqm 12mm cement plaster 1:4 (1 cement : 4 fine sand)……….5.66 Sqm Refilling the pipeline/foundation trenches plinth sides, foundation etc. with available excavated earth in layers not exceeding 20 cm depth consolidating each layer ramming and watering lead upto 50 M and all lifts and disposal of surplus earth as directed by Engineer in Charge………………..2.93 Cum

1

52918

52918.93



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.