Electricity Department Tender

View complete overview of Goa Electricity Department Tender

Electricity Department Tender

Works
Civil And Construction
Eprocure
Opening Date8 Sep 2023
Closing Date19 Oct 2023
Tender Amount₹ 10,98,028 
Notes
Download

Costs

  • EMD

    ₹ 21,961
  • Document Cost

    ₹ 500
  • Tender Fee

    ₹ 2,196

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
Providing and laying in position cement concrete 1:2:4( 1 cement:2 coarse sand :4 graded granitic or basaltic stone aggregate 40m norminal size) exluding cost of centering, shuttering and finishing:

3.99

22164

5555

... More
Supply of Enamelled danger boards 11000 Volts as per drg no. CEE/E-490

4

992

248

... More
Supply of Anti climbing device ( HDGI Barbed wire 1 kg) alongwith suitable two stay clamps & two pairs of H.D.G.I nuts bolts as per drg No. CEE/E-478

4

3848

962

... More
Supply of H.D.G.I. stay rod of 1200mm long & 16mm dia with an eye band of internal dia 40mm at one end & threaded up to length of 200mm at the other end, H.D.G.I. stay plate 450x450x8mm size with a hole for at the centre to suit above stay rod, H.D.G.I. stay wire of size 7/5.15mm (7/8SWG) conforming to IS-2141/1979 grade- I, IS:4826-1979 & IS:6594-1974 or latest version thereof with tensile grade 4 & having minimum tensile strenght of 700N/mm2, H.D.G.I. turn buckle made out of 16mm dia H.D.G.I. rod & H.D.G.I. angle of size ISA 50x50x6mm, eye bolt made out of 20mmdia H.D.G.I. rod with 40mm dia inner dia eye at one end & threaded up to 300mm lenght from other side, along with H.D.G.I. hexagonal nuts suitable for above rod , break insulator of 8KV & minimum failing load of 44KN, & along with suitable H.D.G.I. stay clamps suitable for 11.0 mts long RCC pole, H.D.G.I. nut bolts & of specifications as specified in drg nos. CEE/E-797, CEE/E-466, CEE/E-524, CEE/E-523 & CEE/E-711

1

4613

4613.57

... More
Supply of HDGI cut point channel of ISMC 75X 40 X6MM 1.3 mts long

2

3918

1959

... More
Supply of HDGI Guard cross arm of Channel ISMC 75 X 40 X 6mm 1.5 mtr Long

6

13176

2196

... More
Supply of HDGI 11 KV V -Shape ` X ` Arm of channel ISMC 75 x40 x6mm CEE/E-408-R1

3

4407

1469

... More
Supply of HDGI Top fitting cross arm ISMC channel 75 X 40mm,0.7 mts long.

2

1638

819

... More
Supply of HDGI Top fitting for LT/11KV CEE/E-511

3

2457

819

... More
Supply of Earthing complete with chamber as per drg/ No. CEE/E-830. Each earthing should consist as follows a) 40 mm. Dia 2.5 mtr long, class B GI pipe 1 No. b)HDGI nut bolts, clamps 1 set, c)Brick masonary-0.108 Cu.mts d) PVC pipe 50mm dia- 0.2mtr e) Salt-20 Kgs f) Charcoal-20 Kgs g) Excavation-0.864 Cu. Mtr h) refilling-0.74 Cu.mtr as per drg. No.CEE/E-830.

7

19110

2730

... More
Supply of HDGI structure material for 12 DPS. Each trasformer centre DP consist of HDGI structure material as follows: a) GI channel ISMC 75x40x7.3mm 2.75 mtrs long 2 pieces for incoming line & installation of disc insulators b) GI channel ISMC75x40x7.3mm 2.75mtrs long 2 pieces for GOAB switch c) GI channel ISMC 75x40x7.3mm 2.75 mtrs long 2 pieces for HG fuses d) GI channel ISMC 75x40x7.3mm 2.75 mtrs long 2 pieces for installation of lightening arrestor e) GI channel ISMC 100x50x7.3mm 2.75 mtrs long 2 pieces for installation of Trasformer f) GI channel ISMC 75x40x7.3mm 2.75 mtrs long 2 pieces for side support of trasformer g) GI channel ISMC 75x40x7.3mm 2.75 mtrs long 4 pieces for installation of any other items h) GI channel ISMC 100x40x7.3mm 0.52 mtrs long 2 pieces for installation of Transformer base channel

260

43940

169

... More
Supply of HDGI Nut & boltes ,G.I.Hexagonal head bolts and hexagonal nuts conforming to IS 1363 part 1 to 3 1992 as amended upto date .Thr bolts and nuts shall be hot dip galvanized as per Is:2629-1985 as amended upto date ,full thread.(100 mm X 16mm )

33.56

7651

228

... More
Supply of HDG L.T. 2 pin cross arm Channel type made of ISMC 75x40x7.3mm as per drg No.CEE/E-491

8

4552

569

... More
Supply of HDG L.T. 4 pin cross arm Channel type made of ISMC 75x40x7.3mm as per drg No.CEE/E-491

11

12199

1109

... More
Supply of HDGI X arm clamps for RCC pole 11.0 mtrs LONG LA/SA type as per drg. No.CEE/E-711

32

13248

414

... More
Supply of HDGI X arm clamps for RCC pole 9.0 mtrs LONG LA/SA type as per drg. No.CEE/E-712

2

532

266

... More
Supply of HDGI Stay clamp for RCC pole 11.0 mtrs long LA/SA type as per drg. No.CEE/E-711

2

1242

621

... More
Supply of HDGI Stay clamp for RCC pole 9.0 mtrs long LA/SA type as per drg. No.CEE/E-712

2

982

491

... More
Supply of 11 KV brown glazed porcelain Pin Insulator with minimum failing load of 5 KN and the minimum creepage distance of 320mm conforming to IS 731-1971 as amended upto date. And forged GI pin conforming to IS 2486 part 1 & 2 as amended upto date suitable for 11 KV glazed porcelain pin insulators conforming to IS 731/71 as amended upto date. GI pin shall conform to reference S-165 N fig 5 of IS 2486/(part-II)/74 as amended upto date. Dimension X in said fig shall be 150mm (screwed 100mm). Pin shall be supplied along with one suitable GI hexagonal nut and GI spring washer. Minimum failing load of pin shall be 10 KN.

9

6237

693

... More
Supply of 11 KV Disc Insulators ball and socket type, A porcelain brown glazed duly cemented at factory with MCI socket cap, forged steel ball pin and supplied with Phosphor bronze "W" split pin as per IS 731-1971 as amended upto date. Minimum failing load 70 KN Pin ball diameter 16 mm. Minimum Creepage distance 320 mm with 2 bolted type hardware fitting 70KN suitable for 11 KV ball and socket type disc insulators of 16 mm pin, failing load of 70 KN and suitable for ACSR conductor of size upto 18 mm diameter. The metal parts shall be as per drg No CC/E-482-Rev-2 Benclosed and conform to IS-2486 part 1-1993, 2486 Part-2-1989 as amended upto date.

6

17316

2886

... More
Supply of ACSR Conductor Hard drawn stranded aluminium conductor with galvanized steel wire reinforced conforming to IS: 398(PartII-96) amended upto date of the following sizes. WEASEL 6/1/2.59 (nominal aluminium area 30 Sq.mm.) (139 amp max at 45 °C)

0.6

20045

33409

... More
Supply of ACSR Raccon Conductor Hard drawn stranded aluminium conductor with galvanized steel wire reinforced conforming to IS: 398(PartII-96) amended upto date of the following sizes. Raccon

0.06

5189

86496

... More
Supply of AAC conductor hard drawn stranded all aluminium conductor conforming IS 398(Part-1/96) as amended upto date of following sizes 7/3.10 mm ANTconductor

0.56

26928

48086

... More
Supply of AAC conductor hard drawn stranded all aluminium conductor conforming IS 398(Part-1/96) as amended upto date of following sizes 7/2.21 mm GNAT conductor

0.61

15428

25293

... More
Supply of 11 KV rated voltange GOAB switches tilting type, outdoor, manually operated, triple pole, single break, conforming to IS: 9921-Part 1 to V as amended up to date and detailed specification eclosed herewith. Each set shall comprise of six pedestal and three tilting post insulators. Insulator should be factory cemented by the manufacturer of the insulators and have minimum 320 mm creepage distance and AB switchs contacts shall be of copper/ copper alloy. The AB switch shall be of following current rating: 200 A

1

23535

23535

... More
Supply of 11 KV , 200 A Horn gap fuse unit (Set of three) shall be as per enclosed drg No. CEE/E-786. Revision 3 and detailed specifications enclosed herewith.

1

10450

10450

... More
Supply of 9 KV, 5 KA nominal discharge current metal oxide gapless distribution class Lightning arrestor conforming to IEC-600994-4 and IS: 3070 part 3 1993 as amended upto date suitable for 11 KV 50 HZ effectively earthed neutral system with necessary mounting arragements and connector suitable to connect ASCR conductor upto overall diameter 12.30 mm

3

9099

3033

... More
Supply of MS Distribution box as per drg No. CEE/E-689 Revision No. 3 along with MCCB 400 A, 415V, AC 50 Hz & Bus bar made out of Aluminium strips 40 x 10 mm, Other accessories & aluminium 'J' type fuse links (Set of 3) for 4 feeder arrangement for 200 KVA Distribution Transformer centre

1

63140

63140

... More
Supply of Distribution Transformer Metering unit

1

25688

25688

... More
Supply of Modem for Automatic Meter Reading

1

6000

6000

... More
Supply of Distribution Transformer 200 KVA 11/0.44 KVA level II losses,Aluminium winding with Bimetallic terminal connectors, Energy Efficiency level-II as per IS: 1180(part-I):2014

1

377405

377405

... More
Single core unarmoured XLPE cable of size 185 Sq.mm cross linked polyethelene insulated, PVC shealthed 1core 185 sqmm cable of 1100 volts grade.

40

9800

245

... More
Supply of Single core unarmoured XLPE cable of size 95 Sq.mm cross linked polyethelene insulated, PVC shealthed 1core 95 sqmm cable of 1100 volts grade.

120

15360

128

... More
Supply of LT brown glazed porcelain Pin Insulator with minimum failing load of 5 KN and the minimum creepage distance of 320mm conforming to IS 731-1971 as amended upto date. And forged GI pin conforming to IS 2486 part 1 & 2 as amended upto date suitable for LT glazed porcelain pin insulators conforming to IS 731/71 as amended upto date. GI pin shall conform to reference S-165 N fig 5 of IS 2486/(part-II)/74 as amended upto date. Dimension X in said fig shall be 150mm (screwed 100mm). Pin shall be supplied along with one suitable GI hexagonal nut and GI spring washer. Minimum failing load of pin shall be 10 KN.

20

5260

263

... More
Supply of LT brown glazed shackle Insulator of size 100 mm x 115 mm conforming to fig No. 4 and type 2 fo IS: 1445/77 as amended upto date. Minimum failing load shall be 16 KN with GI hardware suitable for LT shackle insulator of size 100 x 115 mm conforming to type 2 fig 4 of IS: 1445/77 as amended upto date. Hardware or fitting shall conform to fig 4 of IS: 7935-1975 as amended upto date comprise fo 2 GI strips, 2 GI bolts and 2 nuts with spring washers.

46

17112

372

... More
Supply of Aluminium Lug Hole Type 185 sq.mm

8

624

78

... More
Supply of Aluminium Lug Hole Type 95 sq.mm

24

960

40

... More
Supply of Aluminium Lug Hole Type 70 sq.mm

30

1020

34

... More
Supply of Single Phase CCMS Panel for street light

1

11500

11500

... More
Supply of PVC wire 2 core 10sq.mm,1.1 KV grade

40

1560

39

... More
Cost of Erection

-

-

-

... More
Erection of RCC pole 11.0mtr as per the drawing No.CEE/E-565 REV-3 as per annexure confirming to IS 785-1998 as amended upto date. The component used for pole shall conform to following IS amended up to date. 1) Ordinary Port land cement 53 grade IS 12269 2) Aggregate IS 383-1970 3) Torsteel IS 1786-7985 4) MS bar IS 432 p 1 & 2-1982

4

34400

8600

... More
Erection of RCC pole 9.0mtr as per the drawing No.CEE/E-565 REV-3 as per annexure confirming to IS 785-1998 as amended upto date. The component used for pole shall conform to following IS amended up to date. 1) Ordinary Port land cement 53 grade IS 12269 2) Aggregate IS 383-1970 3) Torsteel IS 1786-7985 4) MS bar IS 432 p 1 & 2-1982

2

8816

4408

... More
Erection ofEnamelled danger boards 11000 Volts as per drg no. CEE/E-490

4

228

57

... More
Erection ofAnti climbing device ( HDGI Barbed wire 1 kg) alongwith suitable two stay clamps & two pairs of H.D.G.I nuts bolts as per drg No. CEE/E-478

4

700

175

... More
Erection of H.D.G.I. stay rod of 1200mm long & 16mm dia with an eye band of internal dia 40mm at one end & threaded up to length of 200mm at the other end, H.D.G.I. stay plate 450x450x8mm size with a hole for at the centre to suit above stay rod, H.D.G.I. stay wire of size 7/5.15mm (7/8SWG) conforming to IS-2141/1979 grade- I, IS:4826-1979 & IS:6594-1974 or latest version thereof with tensile grade 4 & having minimum tensile strenght of 700N/mm2, H.D.G.I. turn buckle made out of 16mm dia H.D.G.I. rod & H.D.G.I. angle of size ISA 50x50x6mm, eye bolt made out of 20mmdia H.D.G.I. rod with 40mm dia inner dia eye at one end & threaded up to 300mm lenght from other side, along with H.D.G.I. hexagonal nuts suitable for above rod , break insulator of 8KV & minimum failing load of 44KN, & along with suitable H.D.G.I. stay clamps suitable for 11.0 mts long RCC pole, H.D.G.I. nut bolts & of specifications as specified in drg nos. CEE/E-797, CEE/E-466, CEE/E-524, CEE/E-523 & CEE/E-711

1

2536

2536.34

... More
Erection of HDGI cut point channel of ISMC 75X 40 X6MM 1.3 mts long

2

984

492

... More
Erection of HDGI Guard cross arm of Channel ISMC 75 X 40 X 6mm 1.5 mtr Long

6

3276

546

... More
Erection of HDGI 11 KV V -Shape ` X ` Arm of channel ISMC 75 x40 x6mm CEE/E-408-R1

3

1014

338

... More
Erection of HDGI Top fitting cross arm ISMC channel 75 X 40mm,0.7 mts long.

2

456

228

... More
Erection of HDGI Top fitting for LT/11KV CEE/E-511

3

684

228

... More
Erection of Earthing complete with chamber as per drg/ No. CEE/E-830. Each earthing should consist as follows a) 40 mm. Dia 2.5 mtr long, class B GI pipe 1 No. b)HDGI nut bolts, clamps 1 set, c)Brick masonary-0.108 Cu.mts d) PVC pipe 50mm dia- 0.2mtr e) Salt-20 Kgs f) Charcoal-20 Kgs g) Excavation-0.864 Cu. Mtr h) refilling-0.74 Cu.mtr as per drg. No.CEE/E-830.

7

17108

2444

... More
Erection of HDGI structure material for 12 DPS. Each trasformer centre DP consist of HDGI structure material as follows: a) GI channel ISMC 75x40x7.3mm 2.75 mtrs long 2 pieces for incoming line & installation of disc insulators b) GI channel ISMC75x40x7.3mm 2.75mtrs long 2 pieces for GOAB switch c) GI channel ISMC 75x40x7.3mm 2.75 mtrs long 2 pieces for HG fuses d) GI channel ISMC 75x40x7.3mm 2.75 mtrs long 2 pieces for installation of lightening arrestor e) GI channel ISMC 100x50x7.3mm 2.75 mtrs long 2 pieces for installation of Trasformer f) GI channel ISMC 75x40x7.3mm 2.75 mtrs long 2 pieces for side support of trasformer g) GI channel ISMC 75x40x7.3mm 2.75 mtrs long 4 pieces for installation of any other items h) GI channel ISMC 100x40x7.3mm 0.52 mtrs long 2 pieces for installation of Transformer base channel

260

12220

47

... More
Erection of HDGI Nut & boltes ,G.I.Hexagonal head bolts and hexagonal nuts conforming to IS 1363 part 1 to 3 1992 as amended upto date .Thr bolts and nuts shall be hot dip galvanized as per Is:2629-1985 as amended upto date ,full thread.(100 mm X 16mm )

33.56

1006

30

... More
Erection of HDG L.T. 2 pin cross arm Channel type made of ISMC 75x40x7.3mm as per drg No.CEE/E-491

8

1856

232

... More
Erection of HDG L.T. 4 pin cross arm Channel type made of ISMC 75x40x7.3mm as per drg No.CEE/E-491

11

2871

261

... More
Erection of HDGI X arm clamps for RCC pole 11.0 mtrs LONG LA/SA type as per drg. No.CEE/E-711

32

2080

65

... More
Erection of HDGI X arm clamps for RCC pole 9.0 mtrs LONG LA/SA type as per drg. No.CEE/E-712

2

90

45

... More
Erection of HDGI Stay clamp for RCC pole 11.0 mtrs long LA/SA type as per drg. No.CEE/E-711

2

196

98

... More
Erection of HDGI Stay clamp for RCC pole 9.0 mtrs long LA/SA type as per drg. No.CEE/E-712

2

158

79

... More
Erection of 11 KV brown glazed porcelain Pin Insulator with minimum failing load of 5 KN and the minimum creepage distance of 320mm conforming to IS 731-1971 as amended upto date. And forged GI pin conforming to IS 2486 part 1 & 2 as amended upto date suitable for 11 KV glazed porcelain pin insulators conforming to IS 731/71 as amended upto date. GI pin shall conform to reference S-165 N fig 5 of IS 2486/(part-II)/74 as amended upto date. Dimension X in said fig shall be 150mm (screwed 100mm). Pin shall be supplied along with one suitable GI hexagonal nut and GI spring washer. Minimum failing load of pin shall be 10 KN.

9

1368

152

... More
Erection of 11 KV Disc Insulators ball and socket type, A porcelain brown glazed duly cemented at factory with MCI socket cap, forged steel ball pin and supplied with Phosphor bronze "W" split pin as per IS 731-1971 as amended upto date. Minimum failing load 70 KN Pin ball diameter 16 mm. Minimum Creepage distance 320 mm with 2 bolted type hardware fitting 70KN suitable for 11 KV ball and socket type disc insulators of 16 mm pin, failing load of 70 KN and suitable for ACSR conductor of size upto 18 mm diameter. The metal parts shall be as per drg No CC/E-482-Rev-2 Benclosed and conform to IS-2486 part 1-1993, 2486 Part-2-1989 as amended upto date.

6

2250

375

... More
Erection of ACSR Conductor Hard drawn stranded aluminium conductor with galvanized steel wire reinforced conforming to IS: 398(PartII-96) amended upto date of the following sizes. WEASEL 6/1/2.59 (nominal aluminium area 30 Sq.mm.) (139 amp max at 45 °C)

0.6

4266

7110

... More
Erection of ACSR Raccon Conductor Hard drawn stranded aluminium conductor with galvanized steel wire reinforced conforming to IS: 398(PartII-96) amended upto date of the following sizes. Raccon

0.06

620

10334

... More
Erection of AAC conductor hard drawn stranded all aluminium conductor conforming IS 398(Part-1/96) as amended upto date of following sizes 7/3.10 mm ANTconductor

0.56

3715

6634

... More
Erection of AAC conductor hard drawn stranded all aluminium conductor conforming IS 398(Part-1/96) as amended upto date of following sizes 7/2.21 mm GNAT conductor

0.61

3771

6183

... More
Erection of 11 KV rated voltange GOAB switches tilting type, outdoor, manually operated, triple pole, single break, conforming to IS: 9921-Part 1 to V as amended up to date and detailed specification eclosed herewith. Each set shall comprise of six pedestal and three tilting post insulators. Insulator should be factory cemented by the manufacturer of the insulators and have minimum 320 mm creepage distance and AB switchs contacts shall be of copper/ copper alloy. The AB switch shall be of following current rating: 200 A

1

3971

3971

... More
Erection of 11 KV , 200 A Horn gap fuse unit (Set of three) shall be as per enclosed drg No. CEE/E-786. Revision 3 and detailed specifications enclosed herewith.

1

3368

3368

... More
Erection of 9 KV, 5 KA nominal discharge current metal oxide gapless distribution class Lightning arrestor conforming to IEC-600994-4 and IS: 3070 part 3 1993 as amended upto date suitable for 11 KV 50 HZ effectively earthed neutral system with necessary mounting arragements and connector suitable to connect ASCR conductor upto overall diameter 12.30 mm

3

522

174

... More
Erection of MS Distribution box as per drg No. CEE/E-689 Revision No. 3 along with MCCB 400 A, 415V, AC 50 Hz & Bus bar made out of Aluminium strips 40 x 10 mm, Other accessories & aluminium 'J' type fuse links (Set of 3) for 4 feeder arrangement for 200 KVA Distribution Transformer centre

1

8795

8795

... More
Erection of Distribution Transformer Metering unit

1

1072

1072

... More
Erection of Distribution Transformer 200 KVA 11/0.44 KVA level II losses,Aluminium winding with Bimetallic terminal connectors, Energy Efficiency level-II as per IS: 1180(part-I):2014

1

15638

15638

... More
Erection of Single core unarmoured XLPE cable of size 185 Sq.mm cross linked polyethelene insulated, PVC shealthed 1core 185 sqmm cable of 1100 volts grade.

40

6800

170

... More
Erection of Single core unarmoured XLPE cable of size 95 Sq.mm cross linked polyethelene insulated, PVC shealthed 1core 95 sqmm cable of 1100 volts grade.

120

10920

91

... More
Erection of LT brown glazed porcelain Pin Insulator with minimum failing load of 5 KN and the minimum creepage distance of 320mm conforming to IS 731-1971 as amended upto date. And forged GI pin conforming to IS 2486 part 1 & 2 as amended upto date suitable for LT glazed porcelain pin insulators conforming to IS 731/71 as amended upto date. GI pin shall conform to reference S-165 N fig 5 of IS 2486/(part-II)/74 as amended upto date. Dimension X in said fig shall be 150mm (screwed 100mm). Pin shall be supplied along with one suitable GI hexagonal nut and GI spring washer. Minimum failing load of pin shall be 10 KN.

20

3460

173

... More
Erection of LT brown glazed shackle Insulator of size 100 mm x 115 mm conforming to fig No. 4 and type 2 fo IS: 1445/77 as amended upto date. Minimum failing load shall be 16 KN with GI hardware suitable for LT shackle insulator of size 100 x 115 mm conforming to type 2 fig 4 of IS: 1445/77 as amended upto date. Hardware or fitting shall conform to fig 4 of IS: 7935-1975 as amended upto date comprise fo 2 GI strips, 2 GI bolts and 2 nuts with spring washers.

46

9568

208

... More
Erection of Aluminium Lug Hole Type 185 sq.mm

8

760

95

... More
Erection of Aluminium Lug Hole Type 95 sq.mm

24

1560

65

... More
Erection of Aluminium Lug Hole Type 70 sq.mm

30

1770

59

... More
Erection of Single Phase CCMS Panel for street light

1

900

900

... More
Erection of PVC wire 2 core 10sq.mm,1.1 KV grade

40

440

11

... More
Removing & re-stringing of AA Ant conductor

0.48

4776

9951

... More
Removing & restringing of AA GNAT Conductor

0.48

4451

9274.5



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.